2 One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized care to one patient. The science and art of medical care is to provide the right solution for each individual patient. This requires clinical mastery, a human connection between the surgeon and the patient, and the right tools for each situation. At Biomet, we strive to view our work through the eyes of one surgeon and one patient. We treat every solution we provide as if it s meant for a family member. Our approach to innovation creates real solutions that assist each surgeon in the delivery of durable personalized care to each patient, whether that solution requires a minimally invasive surgical technique, advanced biomaterials or a patient-matched implant. When one surgeon connects with one patient to provide personalized care, the promise of medicine is fulfilled.
3 Taperloc Complete Hip System Over the past 26 years, the Taperloc Hip stem has become the industry standard in cementless hip arthroplasty. 1 Combining this unmatched clinical success with Biomet s commitment to product innovation, the Taperloc Complete Hip system has been introduced with design enhancements that restore leg length, stability, offset and range of motion (ROM) accurately and consistently. Clinical Success of the Taperloc Hip System 100% Survivorship at a minimum 5 year follow-up in 49 rheumatoid patients 2 100% Survivorship at a 2 11 year follow-up in 114 patients 80 years old or older % Survivorship at a 12 year follow-up of 4,750 patients 4 99% Survivorship at a year follow-up in 138 patients 1 99% Survivorship at a 12 year follow-up in 115 patients 5 98% Survivorship at 8 13 year follow-up in 91 patients 50 years old or younger 6 95% Survivorship at a year follow-up in 89 obese patients 7 94% Survivorship at a year follow-up in 99 non-obese patients 7 1
4 Taperloc Complete Full Profile Hip Stem Polished Anterior-Posterior Neck Flats Increase ROM by geometrically reducing the potential for impingement of the neck with the cup 8 Rotational Stability Insertion Hole Provides rotational stability upon implantation Clinically Proven PPS Application Allows for initial scratch-fit stability and bone fixation 2,3,9,10 Optimal Neck Angle 133 neck angle increases ROM and improves stability through increased soft tissue tension Offset Option Standard and high offset options reproduce various patient anatomies without lengthening the leg Acetabular Options 2 Exceed ABT with Biolox delta Ceramic Tapered Liner and 15 shell Improved wear resistance and mechanical strength compared to alumina ceramic. Increased diameters improve ROM 15 shell option allows more coverage Clinically proven PPS coating 9,17 Exceed ABT with E1 Utilises clinically proven RingLoc mechanism E1 Antioxidant Infused Technology developed from clinically proven ArCom 18,19 Ultra low wear versus standard polyethylene 20 Range of liner types and sizes to better address clinical need: Standard, Hi-Wall and 10 Degree 22, 28, 32, 36 and 40 mm liners
5 BoneMaster Nano-Crystalline HA Coating Technology BoneMaster Coating Provides enhanced implant stability, 11 reduced fibrous in-growth 11,12 and increased bone density 12,13 BoneMaster is an advanced biomimetic coating technology with the biological benefits of hydroxyapatite and an enhanced needle-like nano-structure based on apatite crystals found in bone. 26 This technology offers enhanced implant stability, 11 reduced fibrous in-growth 11,12 and increased bone density. 12,13 Flat Tapered Wedge Geometry Enhances proximal offloading and bone preservation and provides for rotational stability 2µm BoneMaster coating Bone Titanium Alloy Ti-6AL-4V Flexibility of titanium allows for stress transfer to preserve cortical density The unique needle-like topography of BoneMaster creates a favorable environment for osteoblast adhesion, producing faster bone integration. The 5μm thick BoneMaster coating preserves the macro-roughness and porosity of PPS (Porous Plasma Spray) Ti-alloy coating for enhanced primary and long-term fixation Dual Mobility Technology Large head for reduced risk of dislocation 21 Large ROM 22 90% lower wear than traditional ArCom 23 Clinically proven cup design 24,25 Available in Active Articulation and Avantage Dual Mobility System constructs Uncoated Surface Fibrous tissue Bone tissue BoneMaster Coating Titanium 3
6 Taperloc Complete Reduced Distal Hip Stem Polished Anterior-Posterior Neck Flats Increase ROM by geometrically reducing the potential for impingement of the neck with the cup 8 Rotational Stability Insertion Hole Provides rotational stability upon implantation Clinically Proven PPS Application Allows for initial scratch-fit stability and bone fixation 2,3,9,10 Optimal Neck Angle 133 neck angle increases ROM and improves stability through increased soft tissue tension E1 Technology Offset Option Standard and high offset options reproduce various patient anatomies without lengthening the leg Reduced Distal Transition Enhances implant fit in femoral canals with a proximal/distal mismatch Infused with vitamin E, a natural antioxidant, E1 Technology defines a new class of acetabular bearings. It overcomes the limitations of remelted and annealed polyethylenes, as well as blended antioxidant polyethylenes, by maximizing ultra-low wear, high mechanical strength and true oxidative stability. 30,31 Oxidation Index (Absorbance Units) Oxidation Profile 30,32 After ESC testing -0.1 Top Surface Center Bottom Surface Sequentially Crosslinked and Annealed Loaded Sequentially Crosslinked and Annealed Control E1 Material Loaded 4 E1 Material Control
7 Taperloc Complete Reduced Distal Geometry BoneMaster Coating Provides enhanced implant stability, 11 reduced fibrous in-growth 11,12 and increased bone density 12,13 Flat Tapered Wedge Geometry Enhances proximal offloading and bone preservation and provides for rotational stability The Taperloc Complete stem features a reduced distal geometry in which a gradual reduction of the stem substrate occurs distal to the porous coating level. The Taperloc Complete stem s reduced distal geometry enhances the proximal fill of the implant in the metaphysis. This particular design is the optimal choice to address a proximal/distal mismatch, which is common in a Dorr Type A femur, by properly accommodating the proximal metaphysis without the need to fit a narrow distal femoral geometry. This design enhancement is based on the traditional Taperloc Reduced Distal stem which has been clinically successfully for over 16 years. 5 Titanium Alloy Ti-6AL-4V Flexibility of titanium allows for stress transfer to preserve cortical density Volumetric Wear Rates of 38mm Acetabular Liners 30 5 Million Cycles 38mm Head Size 25 Volumetric Wear Rate (mm 3 /MC) % large head wear reduction over ArComXL Polyethylene The Taperloc Complete stem design accurately addresses a proximal/distal mismatch as seen in the x-ray above. 0 CoCr/ BIOLOX ArComXL delta/ Polyethylene ArComXL Polyethylene CoCr/ E1 Material BIOLOX delta/ E1 Material Metal-on- Metal (Run-in Wear) 5
8 Taperloc Complete Microplasty Hip Stem Polished Anterior-Posterior Neck Flats Increase ROM by geometrically reducing the potential for impingement of the neck with the cup 8 Rotational Stability Insertion Hole Provides rotational stability upon implantation Clinically Proven PPS Application Allows for initial scratch-fit stability and bone fixation 2,3,9,10 Optimal Neck Angle 133 neck angle increases ROM and improves stability through increased soft tissue tension Offset Option Standard and high offset options reproduce various patient anatomies without lengthening the leg Reduced Distal Transition Enhances implant fit in femoral canals with proximal/distal mismatch Surgeon Education Opportunities The Anterior Supine Intramuscular (ASI) approach has shown many patient benefits whether utilizing a specialized fracture or standard operating table. Biomet offers a number of resources for surgeons to explore the ASI approach in the manner that best suits surgeon and hospital needs. 6
9 BoneMaster Coating Provides enhanced implant stability, 11 reduced fibrous in-growth 11,12 and increased bone density 12,13 Taperloc Complete Microplasty Stem The Taperloc Complete Microplasty stem is built upon the strong clinical heritage of the Taperloc stem and incorporates the same design enhancements as the Taperloc Complete full length stem. This stem option has been shortened 35 mm from the standard Titanium Alloy Ti-6AL-4V Flexibility of titanium allows for stress transfer to preserve cortical density length stem to better address minimally invasive techniques, provide an alternative to femoral resurfacing and offer a unique solution in cases where a bone conserving prosthesis is desirable. Flat Tapered Wedge Geometry Enhances proximal offloading and bone preservation and provides for rotational stability Reduced Length Stem length reduced 35 mm to preserve soft tissues and bony structures and better accommodate minimally invasive approaches ASI Hip Instructional Courses Courses offered with standard OR and ASI specific tables Led by experienced ASI faculty Didactic and hands-on cadaveric training Surgeon Visitation Program One-on-one experience with ASI surgeon Observe live surgery Discuss implant design and rationale For more information on these opportunities, please visit biometosa.com. 7
10 Taperloc Complete XR 123 Hip Stem Polished Anterior-Posterior Neck Flats Increase ROM by geometrically reducing the potential for impingement of the neck with the cup 8 Rotational Stability Insertion Hole Provides rotational stability upon implantation Clinically Proven PPS Application Allows for initial scratch-fit stability and bone fixation 2,3,9, Neck Angle Addresses varus anatomies or coxa vara femoral types by providing additional horizontal offset and low vertical offset for increased soft tissue tension Reduced Distal Transition Enhances implant fit in femoral canals with proximal/distal mismatch Taperloc Complete Hip System Maximum Offset Range With the introduction of the Taperloc Complete XR 123 stem option, the Taperloc Complete system can accommodate a larger range of offsets to better restore patient biomechanics. The adjacent chart shows the additional offsets achieved with the Taperloc Complete compared to a competitive system. Vertical Offset (mm) Competitive Stem Offset Range Taperloc Complete Standard Offset Range Taperloc Complete High Offset Range Taperloc Complete XR 123 Offset Range Horizontal Offset (mm) 8
11 BoneMaster Coating Provides enhanced implant stability, 11 reduced fibrous in-growth 11,12 and increased bone density 12,13 Titanium Alloy Ti-6AL-4V Flexibility of titanium allows for stress transfer to preserve cortical density Taperloc Complete XR 123 Stem The Taperloc Complete XR 123 stem option has the same stem geometry as the Taperloc Complete Full length and Microplasty stems, but provides a 123 degree neck angle and a shortened neck length by 2 mm. These unique design features help to address femurs with a more varus neck by allowing for additional offset to properly restore hip biomechanics and soft tissue tensioning. 133 Standard Offset 133 High Offset Flat Tapered Wedge Geometry Enhances proximal offloading and bone preservation and provides for rotational stability 123 Neck Angle 133 Standard Offset 133 High Offset Profile Options Available in Full Length Reduced Distal and Microplasty stem options 123 Neck Angle
12 References 1. McLaughlin, J.R. and Lee, K.R. Survivorship at 22 to 26 Years Reported with Uncemented Tapered Total Hip Stem. Orthopedics Today. 30(1): 1, Rothman, R. et al. Cementless Femoral Fixation in the Rheumatoid Patient Undergoing Total Hip Arthroplasty: Minimum 5 Year Results. Journal of Arthroplasty. 16(4): , Keisu, K.S. et al. Primary Cementless Total Hip Arthroplasty in Octogenarians: Two to Eleven Year Follow-up. Journal of Bone and Joint Surgery. 83: 359, Hozack, W. Ten Year Experience with a Wedge Fit Stem. Crucial Decisions in Total Joint Replacement and Sports Medicine. Presentation. Bermuda, McLaughlin, J.R. and Lee, K.R. Cementless Total hip Replacement Using Second-generation Components. Journal of Bone and Joint Surgery (British). 92(12): , McLaughlin, J.R. and Lee, K.R. The Outcome of Total Hip Arthroplasty in Young Patients. 8- to 13-Year Results Using an Uncemented Stem. Clinical Orthopaedics and Related Research. 373: , McLaughlin, J.R. and Lee, K.R. The Outcome of Total Hip Replacement in Obese and Non-obese Patients at 10- to 18-Years. Journal of Bone and Joint Surgery (British) , Davey J.R., Femoral Offset. trends/notes/ Femoral%20Offset.htm (accessed February 15, 2010). 9. McLaughlin, J. et al. Total Hip Arthroplasty with an Uncemented Tapered Femoral Component. Journal of Bone and Joint Surgery. 6(90):1290 6, Rothman, R. et al. Immediate Weight Bearing after Uncemented Total Hip Arthroplasty. Clinical Orthopedics and Related Research. 349: , Schmidmaier G, Wildemann B, Schwabe P, Stange R, Hoffmann J, Südkamp NP, Haas NP, Raschke M (2002) A new electrochemically graded hydroxyapatite coating for osteosynthetic implants promotes implant osteointegration in a rat model. J Biomed Mater Res 63: , 12. Schliephake H, Scharnweber D, Roesseler S, Dard M, Sewing A, Aref A (2006) Biomimetic calcium phosphate composite coating of dental implants, Int J Oral Maxillofac Implants, 21 (5): Schliephake H, Scharnweber D, Dard M, Rößler S, Sewing A and Hüttmann C (2003) Biological performance of biomimetic calcium phosphate coating of titanium implants in the mandible a pilot study in dogs, J Biomed Mat Res 64A: Bourne R.B. and Rorabeck C.H. Soft Tissue Balancing: The Hip. Journal of Arthroplasty. 17(4):17 22, Charnley J. Low Friction Principle. Charnley J. Low Friction Arthroplasty of the Hip. New York: Springer-Verlag. 3 15, McGrory B.J. et al. Effect of Femoral Offset on Range of Motion and Abductor Muscle Strength after Total Hip Arthroplasty. Journal of Bone and Joint Surgery (British). 17(4): 865 9, Nabar, S. et al. Comparison of Second Generation Highly Crosslinked Polyethylenes Under Adverse Aging Conditions. Poster No th Annual Meeting of the Orthopaedic Research Society Biomet Biomaterials Laboratory. The Revolutionary Second Generation Vitamin E Stabilized Highly Crosslinked UHMWPE. Jan Beaule, P.E. et al. Jumbo Femoral Head for the Treatment of Recurrent Dislocation Following Total Hip Replacement. Journal of Bone and Joint Surgery. 84A(2): , Data on file at Biomet. Information of files Avantage ROM not necessarily indicative of clinical performance. 23. Data on File at Biomet. Bench test results not necessarily indicative of clinical performance. 24. Leclercq, S. et al. Charnley-Kerboull-Bonsquet Hybrid THR After 10 Years. Total Hip Arthroplasty. Conference. 3rd International Symposium Tarasevicius, S., Busevicius, M., Robertsson, O., Wingstrand, H. et al. Dual Mobility Cup Reduces Dislocation Rate After Arthroplasty for Femoral Neck Fracture. BMC Musculoskeletal Disorders Journal. 11:175, Robler S, Sewing A, Stolzel M, Born R, Scharnweber S, Dard M, Warch H (2003) Electrochemically assisted deposition of thin calcium phosphate coating at near-physiological ph and temperature. JBiomet Mater Res 64A: Mont MA, Hungarford DS (1997) Proximally Coated Ingrowth Prosthesis. A Review. Clin Orthop 344: Emerson RH, Sanders SB, Head WC, Higgins L (1999) Effect of circumferential plasma-spray porous coating on the rate of femoral osteolysis after total hip arthroplasty. JBJS 81: Bourne RB, Rorabeck CH, Burkart BC, Kirk P (1994) Ingrowth surfaces: Plasma spray coating to titanium alloy hip replacements. Clin Orthop Relat Res 298: Data on file at Biomet. Bench test results not necessarily indicative of clinical performance. 31. Kurtz, S. et al. The UHMWPE Handbook: Ultra High Molecular Weight Polyethylene in Total Joint Replacement. Elsevier Academic Press. San Diego, CA Nabar, S. et al. Comparison of Second Generation Highly Crosslinked Polyethylenes Under Adverse Aging Conditions. ORS Poster No Kennon R. et al. Anterior Approach for Total Hip Arthroplasty: Beyond the Minimally Invasive Technique. Journal of Bone and Joint Surgery. 86(2): 91 7, Nakata, K. et al. A Clinical Comparative Study of the Direct Anterior With Mini-Posterior Approach. Journal of Arthroplasty. 24(5): , Bal, B.S. et al. Early Complications of Primary Total Hip Replacement Performed with a Two-Incision Minimally Invasive Technique. Journal of Bone and Joint Surgery. 87(11): , Multi-Center Study. Data on file at Biomet. 18. Meding, J. 4.4mm of Tibial Polyethylene: A Ten-Year Follow-Up Study. Clinical Orthopedics and Related Research. 388: BIOLOX delta is a trademark of CeramTec AG. All trademarks herein are the property of Biomet, Inc. or its subsidiaries unless otherwise indicated. This publication and all content, artwork, photographs, names, logos and marks contained in it are protected by copyright, trademarks and other intellectual property rights owned by or licensed to Biomet or its affiliates. This publication must not be used, copied or reproduced in whole or in part for any purposes other than marketing by Biomet or its authorized representatives. Use for any other purposes is prohibited Biomet Orthopedics Form No. FLH235 REV Responsible Manufacturer Biomet, inc. P.O. Box E. Bell Drive Warsaw, Indiana USA European Representative Biomet UK, Ltd. Waterton Industrial Estate Bridgend, South Wales CF31 3XA UK
ReCap Product Rationale
FLH 155 01/09 Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom Tel. +44 (0)1656 655221 Fax. +44 (0)1656 645454 ReCap Product Rationale A complete resurfacing system
Why an Exactech Hip is Right for You
Why an Exactech Hip is Right for You Why do I need a total hip replacement? Which surgical approach is best for me? How long will it last? Which implant is right for me? Founded in 1985 by an orthopaedic
Clinically Proven Fiber Metal Material. Power to choose advanced bearing technologies to match patient demands
Trilogy IT Acetabular System Design Rationale 1 For orthopedic surgeons treating a wide range of patients, the Trilogy IT Acetabular System provides a clinically proven1-5 Fiber Metal Material and the
Accolade. System. Brochure. Achieving Perfect Balance. Cemented and Cementless Femoral Hip System
Accolade System Brochure Achieving Perfect Balance Cemented and Cementless Femoral Hip System Accolade Cemented Hip System Potential for Perfect Balance The Accolade C Femoral Component: A perfect balance
BONE PRESERVATION STEM
TRI-LOCK BONE PRESERVATION STEM Featuring GRIPTION Technology SURGICAL TECHNIQUE IMPLANT GEOMETRY Extending the TRI-LOCK Stem heritage The original TRI-LOCK Stem was introduced in 1981. This implant was
Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology
Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology Hips designed to fit the unique anatomies of men and women Independent control for a natural fit Simple, practical solutions for optimal restoration
Total Hip Joint Replacement. A Patient s Guide
Total Hip Joint Replacement A Patient s Guide Don t Let Hip Pain Slow You Down What is a Hip Joint? Your joints are involved in almost every activity you do. Simple movements such as walking, bending,
M 2 a-magnum. Design Rationale. Large Metal Articulation. Knees Hips Extremities Cement and Accessories PMI. Technology
M 2 a-magnum Large Metal Articulation Design Rationale Knees Hips Extremities Cement and Accessories PMI Technology M 2 a-magnum Large Metal Articulation History of Metal-on-Metal Early metal-on-metal
Acetabular Wedge Augment System
Orthopaedics Acetabular Wedge Augment System Stryker Hips. Implant with confidence. Restoration Acetabular Wedge Augment System Restoration Acetabular Wedge Augments, united with Tritanium, Trident, MDM
frequently asked questions Knee and Hip Joint Replacement Technology
frequently asked questions Knee and Hip Joint Replacement Technology frequently asked questions Knee and Hip Joint Replacement Technology Recently, you may have seen advertisements from legal companies
The Right Choice. Exeter. total hip system
The Right Choice Exeter total hip system Exeter The Right Choice Anatomic Reconstruction Offset The objectives of total hip replacement are to: relieve pain increase mobility and function Achieving a correct
Y O U R S U R G E O N S. choice of. implants F O R Y O U R S U R G E R Y
Y O U R S U R G E O N S choice of implants F O R Y O U R S U R G E R Y Y O U R S U R G E O N S choice of implants F O R Y O U R S U R G E R Y Your Surgeon Has Chosen the C 2 a-taper Acetabular System The
Bringing together proven technologies. Zimmer Continuum Acetabular System
Bringing together proven technologies. Zimmer Continuum Acetabular System The power to meet individual patient needs. Zimmer Continuum Acetabular System provides highly flexible solutions for orthopaedic
Modular Dual Mobility Acetabular Components: An Important Extension of a Proven Approach to Hip Instability
Modular Dual Mobility Acetabular Components: An Important Extension of a Proven Approach to Hip Instability Robert Wetzel, MD, Lalit Puri, MD, S. David Stulberg, MD Disclosure In accordance with ACCME
TOTAL HIP REPLACEMENT FOR A LIFETIME: THE CEMENTLESS METAL ON METAL RECONSTRUCTION
Richard A. Sweet, M.D. Louisville Orthopaedic Clinic Louisville, KY TOTAL HIP REPLACEMENT FOR A LIFETIME: THE CEMENTLESS METAL ON METAL RECONSTRUCTION INTRODUCTION Total hip replacement surgery (THR) has
Metal-on-Metal Hip Systems
Meeting of the Orthopaedic and Rehabilitation Devices Advisory Panel June 27-28, 2012 Metal-on-Metal Hip Systems Center for Devices and Radiological Health U.S. Food and Drug Administration Meeting of
TOTAL HIP REPLACEMENT: MODERN SURGERY FOR SEVERE ARTHRITIS OF THE HIP
TOTAL HIP REPLACEMENT: MODERN SURGERY FOR SEVERE ARTHRITIS OF THE HIP John T. Dearborn, M.D. and Alexander P. Sah, M.D. The Center for Joint Replacement Please read this pamphlet before you see me so that
Hip Resurfacing 2011 ORIGINAL ARTICLE. James W. Pritchett MD. Introduction. Abstract
1 ORIGINAL ARTICLE Hip Resurfacing 2011 James W. Pritchett MD Abstract In 1938 Marion Smith-Peterson placed a cobalt chromium cup on a reshaped femoral head to perform the first hip resurfacing. 15 Also,
NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE. Health Technology Appraisal
NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE Health Technology Appraisal Total hip replacement and resurfacing arthroplasty for the treatment of pain or disability resulting from end stage arthritis
Aesculap Orthopaedics Metha
Aesculap Orthopaedics Metha Short Hip Stem Evolving the State of Arthroplasty 2 Evolving the State of Arthroplasty Contents Short Hip Stem System 4 Short Stem Anchoring Concept 6 Variable Implant Options
ACCOLADE II. Orthopaedics. Femoral Hip System. Surgical Technique
ACCOLADE II Femoral Hip System Orthopaedics Surgical Technique Indications The indications for use of the total hip replacement prostheses include: Noninflammatory degenerative joint disease, including
High-Flex Solutions for the MIS Era. Zimmer Unicompartmental High Flex Knee System
High-Flex Solutions for the MIS Era Zimmer Unicompartmental High Flex Knee System Zimmer Unicompartmental High Flex Knee Built On Success In today s health care environment, meeting patient demands means
on-metal Hips: Device Mechanics and Failure Modes
1 Metal-on on-metal Hips: Device Mechanics and Failure Modes Steven M. Kurtz, Ph.D., and Richard Underwood, Ph.D. Exponent, Inc., and Drexel University NIH R01 AR47904 2 Contracts: DePuy Orthopaedics,
Understanding Total Hip Replacement
Understanding Total Hip Replacement Brian J. White MD Orthopaedic Specialist in Disorders of the Hip Assistant Team Physician Denver Nuggets Western Orthopaedics Denver, Colorado Introduction This is designed
Zimmer M/L Taper Hip Prosthesis. Surgical Technique
Zimmer M/L Taper Hip Prosthesis Surgical Technique Zimmer M/L Taper Hip Prosthesis 1 Zimmer M/L Taper Hip Prosthesis Surgical Technique Table of Contents Preoperative Planning 2 Determination of Leg Length
Custom Design of Knee Joint Prosthesis By Using Computerized Tomography (CT) Images and 3D Modelling
Custom Design of Knee Joint Prosthesis By Using Computerized Tomography (CT) Images and 3D Modelling Qasem Alyazji Near East University, Department of Biomedical Engineering Nicosia, North Cyprus, Turkey
Restoration Modular Cone Body/Conical Distal Stem Femoral Components Using the Restoration Modular Instrument System Surgical Technique
Restoration Modular Cone Body/Conical Distal Stem Femoral Components Using the Restoration Modular Instrument System Surgical Technique CONE CONICAL BROACHED CALCAR MILLED CONE MT3 FLUTED PLASMA CONICAL
P REPLACEMENT SURGERY
P REPLACEMENT SURGERY DIRECT ANTERIOR APPROACH M I N I M I Z I N G R E C O V E R Y. M A X I M I Z I N G R E S U L T S. CENTER FOR MINIMAL INVASIVE JOINT SURGERY 2301 25TH STREET SOUTH FARGO ND 58103 701-241-9300
Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology. Surgical Technique
Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology Surgical Technique Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology 1 Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology Surgical
Answers to commonly asked questions from patients with metal-on-metal hip replacements / resurfacings. Contents
Answers to commonly asked questions from patients with metal-on-metal hip replacements / resurfacings John Skinner 1 and Alister Hart 2, Consultant Orthopaedic Surgeons and Directors of the London Implant
VEGA System. PS Knee Replacement Technology. Aesculap Orthopaedics
VEGA System PS Knee Replacement Technology Aesculap Orthopaedics A pivotal breakthrough in knee replacement. VEGA System PS Knee Replacement Technology Based on a patent-pending post-cam design that optimizes
ABGII Cement Free Total Hip Replacement System
Cement Free Total Hip Replacement System Efficacy Innovation Cement Free Hip System The ABG Cement Free Hip System is one of the foremost ranges of cementless total hip replacement prosthesis. Used extensively
Minimally Invasive Hip Replacement through the Direct Lateral Approach
Surgical Technique INNOVATIONS IN MINIMALLY INVASIVE JOINT SURGERY Minimally Invasive Hip Replacement through the Direct Lateral Approach *smith&nephew Introduction Prosthetic replacement of the hip joint
Zimmer Trabecular Metal Dental Implant
Zimmer Trabecular Metal Dental Implant TRABECULAR METAL MATERIAL: Designed to Enhance Secondary Stability Through Bone Ingrowth. Artistic Rendering osseoincorporation TRABECULAR METAL MATERIAL Designed
Restoration Modular. Revision Hip System Surgical Protocol
Orthopaedics Restoration Modular Revision Hip System Restoration Modular Calcar Body/Conical Distal Stem Femoral Components Using the Restoration Modular Instrument System Revision Hip System Orthopaedics
Exeter. Surgical Technique. V40 Stem Cement-in-Cement. Orthopaedics
Exeter Orthopaedics V40 Stem Cement-in-Cement Surgical Technique Exeter V40 Stem Cement-in-Cement Surgical Technique Table of Contents Indications and Contraindications...2 Warnings and Precautions...2
Oxford Partial Knee. A Definitive Implant. Tibial Component. Anatomical shape for optimal bone coverage
Oxford Partial Knee Oxford Partial Knee A Definitive Implant With over 35 years clinical experience, the Oxford Partial Knee is the most widely used 1 and proven 2 partial knee system in the world. Tibial
.URGENT DEVICE CORRECTION
zimmer.urgent DEVICE CORRECTION Zimmer, Inc. P.O. Box 706 Warsaw, IN 46561-0706 574.267.6131 www.zimmer.com July 22, 2008 Dear Surgeon: Since we last wrote to you in May 2008 regarding the Durom Acetabular
The information contained in this document is intended for healthcare professionals only.
The information contained in this document is intended for healthcare professionals only. Dall-Miles Cabling System Dall-Miles Recon and Trauma Cable System Trochanteric Reattachment Using the Trochanteric
VERSYS HERITAGE CDH HIP PROSTHESIS. Surgical Technique for CDH Hip Arthroplasty
VERSYS HERITAGE CDH HIP PROSTHESIS Surgical Technique for CDH Hip Arthroplasty SURGICAL TECHNIQUE FOR VERSYS HERITAGE CDH HIP PROSTHESIS CONTENTS ANATOMICAL CONSIDERATIONS....... 2 PREOPERATIVE PLANNING............
The information contained in this document is intended for healthcare professionals only.
The information contained in this document is intended for healthcare professionals only. X3 Knee Technology The Next Generation in Highly Crosslinked Knee Polyethylene Innovation Matters As a pioneer
Total hip arthroplasty (THA) through the anterior approach
Primary Total Hip Arthroplasty with a Minimally Invasive Anterior Approach Jonathan G. Yerasimides, MD, and Joel M. Matta, MD Total hip arthroplasty (THA) through the anterior approach is a minimally invasive
it s time for rubber to meet the road
your total knee replacement surgery Steps to returning to a Lifestyle You Deserve it s time for rubber to meet the road AGAIN The knee is the largest joint in the body. The knee is made up of the lower
Metasul LDH Large Diameter Head
Metasul LDH Large Diameter Head Surgical Technique Metasul LDH Large Diameter Head Surgical Technique Enhancing Stability and Increasing Range of Motion Metasul LDH Large Diameter Head Surgical Technique
Graphic courtesy of DePuy Orthopaedics, Inc. HealthEast Joint Replacement Registry: 20 Year Report
Graphic courtesy of DePuy Orthopaedics, Inc. HealthEast Joint Replacement Registry: 20 Year Report HealthEast Joint Replacement Registry: 20 Year Report Foreword HealthEast Care System began the first
Dental Implant Options in Atrophic Jaws
Dental Implant Options in Atrophic Jaws Orthopedic Application Jay B. Reznick, D.M.D., M.D. Diplomate, American Board of Oral and Maxillofacial Surgery Tarzana, CA Endopore Dental Implant System Screw-Type
An Alternative Conservative Approach to Hip Reconstruction
Joint Implant Surgery & Research Foundation Chagrin Falls, Ohio, USA An Alternative Conservative Approach to Hip Reconstruction Craig S. Waller, MD* and Timothy McTighe, Dr. H.S. (hc)** Acknow ledgement:
Design surgeon list. Smith & Nephew thanks the following surgeons for their participation as part of the R3 system design team:
Surgical Technique Design surgeon list Smith & Nephew thanks the following surgeons for their participation as part of the R3 system design team: Robert Barrack, MD St. Louis, Missouri Robert Bourne, MD
INTRODUCTION Cerclage Cable Vs. Monofilament Wire
B M P CABLE S Y S T E M S U R G I C A L TECHNIQUE INTRODUCTION The Biomet Medical Products (BMP ) Cable System provides a cost effective and simple method of trochanteric reattachment, fracture fixation,
A Patient s Guide to Artificial Cervical Disc Replacement
A Patient s Guide to Artificial Cervical Disc Replacement Each year, hundreds of thousands of adults are diagnosed with Cervical Disc Degeneration, an upper spine condition that can cause pain and numbness
Contact: Steve Hurson VP, R & D Nobel Biocare 22715 Savi Ranch Pkwy Yorba Linda, CA 92887 (714) 282-5072 steve.hurson@nobelbiocare.
Use of CP Titanium and Titanium alloys for Dental Implants Steve Hurson, Nobel Biocare U.S.A. Yorba Linda CA Abstract Professor Per Ingvar Branemark of Sweden published his results on 15 years of research
HEADER TOTAL HIP REPLACEMENT SURGERY FROM PREPARATION TO RECOVERY
HEADER TOTAL HIP REPLACEMENT SURGERY FROM PREPARATION TO RECOVERY ABOUT THE HIP JOINT The hip joint is a ball and socket joint that connects the body to the legs. The leg bone is called the femur. The
NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE
NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE Overview Total hip replacement and resurfacing arthroplasty for treating pain or disability resulting from end stage arthritis of the hip (review of technology
Posterior Referencing. Surgical Technique
Posterior Referencing Surgical Technique Posterior Referencing Surgical Technique INTRO Introduction Instrumentation Successful total knee arthroplasty depends in part on re-establishment of normal lower
VERILAST Technology for Hip Replacement Implants
VERILAST Technology for Hip Replacement Implants Surgeon Name Clinic Name Clinic Address Clinic i Address Phone Number Web Address Total Hip Replacement What Is VERILAST Hip Technology? OXINIUM Oxidized
Computer Aided Engineering (CAE) Techniques Applied To Hip Implant
International Journal Of Computational Engineering Research (ijceronline.com) Vol. 3 Issue. 3 Computer Aided Engineering (CAE) Techniques Applied To Hip Implant 1, M. S. Abo_Elkhair, 2, M. E. Abo-Elnor,
Introduction to the Bertram Hip Spacer
Introduction to the Bertram Hip Spacer Approximately 200,000 hip replacement surgeries are done every year in United States. Fortunately the incidence of infection is routinely 0.5 percent-1 percent. However
*smith&nephew SLR-PLUS
Surgical Technique *smith&nephew SLR-PLUS Cementless Revision Stem SLR-PLUS Table of Contents Comments from the Author s Clinic... 3 Indications... 4 Contraindications... 5 Preoperative Planning... 5
PERIPROSTHETIC IMPLANTS
PERIPROSTHETIC IMPLANTS PRODUCT OVERVIEW CLINICAL SOLUTIONS Periprosthetic fractures present unique challenges, such as how to gain fixation when the medullary canal is occupied. Special techniques and
Technology Breakthrough in Spinal Implants (Technical Insights)
Technology Breakthrough in Spinal Implants (Technical Insights) Biomaterial innovations is a growth factor for spinal implant market June 2014 Table of Contents Section Page Number Executive Summary 4
Rejuvenate Total Hip System Surgical Protocol. Rejuvenate Modular Hip Stem Enhanced Stability 1 Proven Modularity 2 Intraoperative Flexibility
Rejuvenate Total Hip System Surgical Protocol Rejuvenate Modular Hip Stem Enhanced Stability 1 Proven Modularity 2 Intraoperative Flexibility Rejuvenate Total Hip System Surgical Protocol Table of Contents
Wear-contact analysis of hip implant coated with functionally graded material
2014; 1(7): 439-443 IJMRD 2014; 1(7): 439-443 www.allsubjectjournal.com Received: 13-12-2014 Accepted: 30-12-2014 e-issn: 2349-4182 p-issn: 2349-5979 Impact Factor: 3.762 Vinod Pallapu M. Tech Student
Anterior Hip Replacement
Disclaimer This movie is an educational resource only and should not be used to manage Orthopaedic health. All decisions about the management of hip replacement and arthritis management must be made in
TOTAL KNEE REPLACEMENT: MODERN SURGERY FOR SEVERE ARTHRITIS OF THE KNEE
TOTAL KNEE REPLACEMENT: MODERN SURGERY FOR SEVERE ARTHRITIS OF THE KNEE John T. Dearborn, M.D. and Alexander P. Sah, M.D. The Center for Joint Replacement Please read this pamphlet before you see me so
Summary of Safety and Effectiveness
Pg.1/3 Summary of Safety and Effectiveness Date: June 11, 2014 U.S. Contact Person: 0 Dr. Stephen J. Peoples Manufacturer: Principal Consultant Limacorporate S.p.A. Phone: 260-645-0327 Via Nazionale, 52
Total Hip Replacement
Please contactmethroughthegoldcoasthospitaswityouhaveanyproblemsafteryoursurgery. Dr. Benjamin Hewitt Orthopaedic Surgeon Total Hip Replacement The hip joint is a ball and socket joint that connects the
The information contained in this document is intended for healthcare professionals only.
The information contained in this document is intended for healthcare professionals only. UHR Universal Head Bipolar System T he Stryker Orthopaedics UHR Universal Head is a leader among bipolar component
TriLock 1.5 Implants for the Phalanges
P R O D U C T IN F O RM AT I O N TriLock 1.5 Implants for the Phalanges APTUS Hand 2 TriLock 1.5 Implants for the Phalanges TriLock 1.5 The Smallest Locking System Small, slender, strong Low profile and
Medical Device Alert. Device All metal-on-metal (MoM) hip replacements. Action by. CAS deadlines. Ref: MDA/2012/036 Issued: 25 June 2012 at 11:00
Medical Device Alert Issued: 25 June 2012 at 11:00 Device All metal-on-metal (MoM) hip replacements Problem The MHRA is issuing updated information and advice about the follow-up of implanted with metal-on-metal
Options for Cervical Disc Degeneration A Guide to the M6-C. clinical study
Options for Cervical Disc Degeneration A Guide to the M6-C clinical study Each year, hundreds of thousands of adults are diagnosed with Cervical Disc Degeneration, an upper spine condition that can cause
PRESENTATIONS/PAPERS INTERNATIONAL. RAISING STANDARDS IN JOINT ARTHROPLASTY Course Co-Chairman, The Great Debate - London, June 2013
PRESENTATIONS/PAPERS INTERNATIONAL 1998 2013 RAISING STANDARDS IN JOINT ARTHROPLASTY Course Co-Chairman, The Great Debate - London, June 2013 HOW TO CHOOSE THE RIGHT STEM FOR THE RIGHT PATIENT Corin Symposium
Total Hip Replacement Hip replacement surgery, or arthroplasty, uses implants to resurface and replace the bones in the joint, re-creating the smooth gliding surfaces that were once intact. Hip replacement
How To Make An Implant From A Metal That Is Like Bone
Trabecular Metal Technology The Best Thing Next to Bone Trabecular Metal Technology The Best Thing Next to Bone When you need a hip, knee, shoulder or spine implant, you want assurance that your implant
ICAS:Advanced Shoulder Arthroplasty Course. Barcelona University - School of Medicine 10-11 March 2015 Barcelona, Spain
ICAS:Advanced Shoulder Arthroplasty Course Instructional Course with Anatomical Specimens Barcelona University - School of Medicine 10-11 March 2015 Barcelona, Spain SKILLS ACADEMY Faculty Dr. Michael
BIOACTIVE COATINGS ON 316L STAINLESS STEEL IMPLANTS
Trends Biomater. Artif. Organs. Vol. 17(2) pp 43-47 (2004) http//www.sbaoi.org BIOACTIVE COATINGS ON 316L STAINLESS STEEL IMPLANTS N. Ramesh Babu*,+, Sushant Manwatkar*, K. Prasada Rao* and T. S. Sampath
Metallurgical analysis of five failed cast cobalt-chromium-molybdenum alloy hip prostheses
Veterans Administration Journal of Rehabilitation Research and Development Vol. 23 No. 4 Pages 27-36 Metallurgical analysis of five failed cast cobalt-chromium-molybdenum alloy hip prostheses STEPHEN D.
Joint Replacement Surgeons of Indiana Foundation. 2012 Laboratory Review
Joint Replacement Surgeons of Indiana Foundation 2012 Laboratory Review Program Overview The Joint Replacement Surgeons of Indiana (JRSI) Research Foundation is a not-for-profit organization committed
Failure Mechanisms and Closed Reduction of a Constrained Tripolar Acetabular Liner
The Journal of Arthroplasty Vol. 24 No. 2 2009 Case Report Failure Mechanisms and Closed Reduction of a Constrained Tripolar Acetabular Liner William J. Robertson, MD, Christopher J. Mattern, MD/MBA, John
Materials Sciences. Dr.-Ing. Norbert Hort [email protected]. International Masters Programme in Biomedical Engineering
Materials Sciences International Masters Programme in Biomedical Engineering Magnesium Innovations Center (MagIC) GKSS Forschungszentrum Geesthacht GmbH Dr.-Ing. Norbert Hort [email protected] Contents
Straumann Dental Implant System. Implant Selection Guide.
Straumann Dental Implant System. Implant Selection Guide. STRAUMANN's IMPLANT PORTFOLIO The Straumann Dental Implant System offers two implant lines with diverse body and neck designs ranging from the
CeraNews The Orthopaedic Landscape Information Journal
CeraNews The Orthopaedic Landscape Information Journal Issue 1/2011 Ceramics in Orthopaedics Editorial 2 Quality First Interview with Richard H. Rothman, MD, PhD 2 US Experience with Ceramics Outcome of
Corporate Medical Policy Computer Assisted Surgical Navigational Orthopedic Procedures
Corporate Medical Policy Computer Assisted Surgical Navigational Orthopedic File Name: Origination: Last CAP Review: Next CAP Review: Last Review: computer_assisted_surgical_navigational_orthopedic_procedures
Titanium Foam Implant
Titanium Foam Implant The Innovator 2 Move Implants is a Research & Development company which focuses on creating innovating products, not only to improve a product, but also the way of doing business.
Validation of biomedical coatings
Synergy makes sence Validation of biomedical coatings MG-FSI72-108 Last revision: March 2011 5, Chemin du Catupolan - 69120 Vaulx en Velin - France - Tel. 33 (0)4 72 81 22 62 - Fax : 33 (0)4 72 81 22 72
YOUR GUIDE TO TOTAL HIP REPLACEMENT
A Partnership for Better Healthcare A Partnership for Better Healthcare YOUR GUIDE TO TOTAL HIP REPLACEMENT PEI Limited M50 Business Park Ballymount Road Upper Ballymount Dublin 12 Tel: 01-419 6900 Fax:
Your Practice Online
P R E S E N T S Your Practice Online Disclaimer This information is an educational resource only and should not be used to make a decision on Revision Hip Replacement or arthritis management. All decisions
OptiLock Periarticular Plating System For Proximal Tibial Fractures. Pre-Launch Surgical Technique
OptiLock Periarticular Plating System For Proximal Tibial Fractures Pre-Launch Surgical Technique Contents Introduction... Page 1 Indications & Fracture Classifications... Page 4 Design Features... Page
Imagine being an orthopedic surgeon and knowing that your patient s
http://www.surgicalproductsmag.com/product-releases/2009/05/safer-methods-internal-bone-fixation Advances in Internal Bone Fixation Sharps safety for orthopedic surgeons by Ron Stoker Imagine being an
EMPLOYMENT: PEACHTREE ORTHOPAEDIC CLINIC ATLANTA- GA 2013- PRESENT Orthopaedic Surgeon Northside Hospital, Atlanta, GA
GEORGE N. GUILD III, M.D. ORTHOPAEDIC SURGEON: ADULT HIP AND KNEE RECONSTRUCTION PEACHTREE ORTHOPAEDIC CLINIC 5505 PEACHTREE DUNWOODY ROAD SUITE 600 ATLANTA, GA 30342 TEL. (404)- 355-0743 FAX: 404-355-
More than a fixed rehabilitation.
More than a fixed rehabilitation. A reason to smile. In combination with: Patient expectations drive dental treatments for fixed edentulous immediate restorations. Patients today have increasingly high
i-polymers for i-arthroplasty New Polymer Technologies for HIP Arthroplasty
i-polymers for i-arthroplasty New Polymer Technologies for HIP Arthroplasty Leo Smit Business Director Implant Solutions Materials that belong to the body Total Hip Arthroplasty One of the largest successes
Introduction to Biomaterials in Orthopaedic Surgery
CHAPTER 1 Introduction to Biomaterials in Orthopaedic Surgery 1.1 Definition of Biomaterial A biomaterial is a material that interacts with human tissue and body fluids to treat, improve, or replace anatomical
Curriculum Vitae Curtis R. Noel, MD
Curriculum Vitae Curtis R. Noel, MD Education Fellowship: Steadman-Hawkins Clinic of the Carolinas 2005 2006 Spartanburg, SC Residency: Summa Health Systems 2000-2005 Akron, OH Medical School: University