Bringing together proven technologies. Zimmer Continuum Acetabular System
|
|
|
- Martin Trevor Hill
- 9 years ago
- Views:
Transcription
1 Bringing together proven technologies. Zimmer Continuum Acetabular System
2 The power to meet individual patient needs. Zimmer Continuum Acetabular System provides highly flexible solutions for orthopaedic surgeons who treat a wide range of patients. The system combines the proven biologic fixation 1,2 of Trabecular Metal technology with Zimmer advanced bearing options. With one comprehensive system, surgeons have the ability to address variations of anatomy and bone quality and choose the bearing technology that best meets the needs of each patient. Highly porous Trabecular Metal Material with over eleven years of clinical history Initial stability 3 Long-term biologic fixation 4,5 Proven clinical history 1,2 Power to choose advanced bearing technologies to match patient demands Surgeons can chose from three liner types based on their patient needs. Longevity Highly Crosslinked Polyethylene is highly resistant to wear 6 and aging 7-15 with over ten years of proven clinical history. 16 Metasul Metal-on-Metal Material s has a very low wear rate 17 with over twenty years of clinical history BIOLOX delta Ceramic affords a very low wear rate in a material with improved mechanical properties compared to traditional ceramics. 26 BIOLOX is a registered trademark of CeramTec AG Corporation
3 Trabecular Metal Cancellous-like Structure with Struts Trabecular Metal Technology Initial Stability Long Term Fixation.98 Coefficient of friction* 3 80% Porosity 4,5 Proven Clinical History 10+ years 1,2 Trabecular Metal Technology offers a high coefficient of friction and scratch fit. Helps reduce or eliminate the need for supplemental screws or grafts Reduces micromotion, enabling tissue ingrowth Trabecular Metal Technology 3D construct provides a high level of porosity and potential for osteoconductivity. Allows for more rapid bone and soft tissue ingrowth Supports a vascularized structure to maintain healthy bone More than 10 years of clinical history, with over 75 peer-reviewed journal publications. More than 250,000 Trabecular Metal Components have been implanted worldwide since * For non-machined surfaces such as the Trabecular Metal Modular Shell and Continuum Shell
4 Longevity Highly Crosslinked Polyethylene Highly reduced wear 89% over standard Polyethylene 6 Proprietary electron beam process delivers 10Mrad dosage for greater crosslinking, resulting in superior longterm polyethylene wear performance. Highly resistant to aging Over 10X fewer free radicals 7,9,27-30 In contrast to warm-annealing, which leaves residual free radicals, meltannealing virtually eliminates free radicals and results in long-term mechanical strength. Works as Predicted 10+ years of clinical experience. 16 More than 1 million Zimmer Highly Crosslinked Polyethylene Liners have been implanted worldwide. 6 Metasul Technology Improved Stability and Function Larger head size leads to greater range of motion and a lower chance for impingement and its associated risks for dislocation. 31,32 Lower wear characteristics Metasul wrought forged surface roughness is greatly reduced, which leads to a lower rate of wear in comparison to cast chromium-cobalt alloys 33-39
5 Optimized clearance provides enhanced lubrication and minimized wear 40,41 Proven Clinical History 20+ years of published clinical history Launched in 1988, with over 460,000 implantations worldwide 6 More than 50 independent publications have discussed the performance of Metasul Technology bearings BIOLOX delta Ceramic Technology A high-performance material that meets the increased demands of young active patients and outperforms earlier versions of ceramic materials. 26 Very Low wear Increased hardness offers resistance to scratching and subsequent wear Better wetting characteristics offer enhanced lubrication and lower wear 26 High fracture resistance Optimum composite balance combines hardness with increased bending strength 26,42
6 Antirotation Scallops Secure Liner Locking Mechanism Longevity Liners The locking groove design, is designed to mate and lock with polyethylene liners. Hard-Bearing Liners Metasul and BIOLOX delta Liners are secured by a taper locking mechanism consisting of a circumferential 18 taper around the outside rim of the liner. These liners are designed with a tapered radius for easier insertion. Tapered for easier and more predictable insertion Threaded Dome Hole Tivanium Alloy Substrate Trabecular Metal Material Polyethylene Locking Groove Hemispherical Shape Integrated Taper Rounded Leading Edge of Taper
7 Shell Design Features Shell Screw Hole Options Shell Screw and Dome Hole Features Dome Hole Plug Screw Hole Screw Hole Plug Uni-hole Cluster-hole Multi-hole
8 References: 1. Unger AS, et al., Evaluation of a porous tantalum uncemented acetabular cup in revision total hip arthroplasty: clinical and radiological results of 60 hips. J Arthroplasty. 20(8); 2005: Macheras GA et al., Eight to Ten-Year Clinical and Radiographic Outcome of a Porous Tantalum Monoblock Acetabular Component, JOA Vol. 00 No , In Press 3. Zhang Y, et al., Interfacial frictional behavior: cancellous bone, cortical bone, and a novel porous tantalum biomaterial. J Musculoskeletal Res. 1999; 3(4): Levine B. A new era in porous metals: applications in orthopaedics. Advanced Engineering Materials. August 2008; 10(9): Barbella M. Materials marvels: titanium is a top choice for implants, but other materials are gaining popularity. Orthopaedic Design & Technology. September 1, Data on file at Zimmer 7. Wannomae KK, et al. In vivo oxidation of retrieved crosslinked ultra-high molecular-weight polyethylene acetabular components with residual free radicals. J Arthroplasty. 2006; 21(7): Medel FJ, Kurtz SM, MacDonald DW, et al. First-generation highly crosslinked polyethylene in THA: clinical and material performance. Las Vegas, 55th Meeting of the Orthopaedic Research Society, Collier JP, et al. Comparison of crosslinked polyethylene materials for orthopaedic applications. Clin Orthop. 2003; 414: Bhattacharyya S et al. Severe In Vivo Oxidation in a Limited Series of Retrieved Highly-Crosslinked UHMWPE Acetabluar Components with Residual Free Radicals, 50th Annual Meeting of the Orthopaedic Research Socieity, Paper 0276, Las Vegas, Jibodh, SR, et al., Minimum Five Year Outcome and Wear Analysis of Large Diameter Femoral Heads on Highly-Cross-linked Polyethylene Liners, Poster No. 2445, 55th Annual Meeting of the Orthopaedic Research Society, Las Vegas, Kärrholm, Digas G, J, Thanner J, Herberts P. Five to seven years experiences of highly crosslinked PE. SICOT Hong Kong, August McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB, Chess DG, Charron KD, Wear Rate of Highly Crosslinked Polyethylene in Total Hip Arthroplasty. A Randomized Controlled Study. J Bone Joint Surg Am. 2009; 91: Bragdon CR, et al., Minimum 6-year Follow up of Highly Crosslinked Polyethylene in THA, Clinical Orthopaedics and Related Research, 2007; Number 465: Digas et al., Crosslinked vs. Conventional Polyethylene in Bilateral Hybrid THR Randomised Radiostereometric Study, 50th Annual Meeting of the Orthopaedic Research Society, Poster No. 0319, Las Vegas, Bragdon, CR, et al., Seven to Ten Year Follow-Up of Highly Crosslinked Polyethylene Liners in Total Hip Arthroplasty, Poster No. 2444, 55th Annual Meeting of the Orthopaedic Research Society, Las Vegas, Rieker CB, Schön R, Köttig P, et al. Development and validation of a second-generation Metal-on- Metal bearing: laboratory study and analysis of retrievals. J Arthroplasty. 2004;19 (8, suppl 3): Sharma S, et al., Metal-on-Metal total hip joint replacement: a minimum follow-up of five years. Hip Int, 2007; 17: Migaud H, et al., Cementless Metal-on-Metal hip arthroplasty in patients less than 50 years of age. Comparison with a matched control group using ceramic-on-polyethylene after a minimum 5-year follow- up. J Arthroplasty 19 (8, suppl 3), 2004, Long WT, et al., An American experience with Metal-on-Metal total hip arthroplasties. A 7-year followup study. J Arthroplasty 19 (8, suppl 3), 2004: Jessen N, et al., Metal/Metal A new (old) hip bearing system in clinical evaluation. Prospective 7-year follow-up study. Orthopäde 2004; 33: Delaunay CP, Metal-on-metal bearings in cementless primary total hip arthroplasty. J Arthroplasty 19(8, suppl 3), 2004: Grübl A, et al., Long-term follow-up of Metal-on-Metal total hip replacement. J Orthop Res, 2007; 25: Eswaramoorthy V, et al., The Metasul Metal-on-Metal articulation in primary total hip replacement: clinical and radiological results at ten years. J Bone Joint Surg Br, 2008; 90B: Delaunay CP, et al., THA using Metal-on-Metal articulation in active patients younger than 50 years. Clin Orthop Relat Res., 466, 2008: Kuntz M, Validation of a New High Performance Alumina Matrix Composite for use in Total Joint Replacement. Seminars in Arthroplasty 17, 2006: Muratoglu OK, et al. Knee-simulator testing of conventional and Crosslinked polyethylene tibial inserts. J Arthroplasty, 2004; 19(7) 28. Muratoglu OK, Bragdon CR, O Connor DO, Jasty M, Harris WH. A novel method of crosslinking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. J Arthroplasty. 2001; 16(2): X3 Brochure, The Power of Technology, Stryker, In a study conducted by the Harris Orthopaedic Biomaterials & Biomechanics Laboratory at Massachusetts General Hospital, free radical levels were measured on conventional polyethylene, Crossfire, X3 acetabular liners and Longevity Polyethylene 31. Amstutz HC, Le Duff MJ, Beaule PE.; Prevention and treatment of dislocation after total hip replacement using large diameter balls. Clin Orthop Relat Res. Dec. 2004; (429): Cuckler JM, Moore KD, Lombardi AV Jr., McPherson E, Emerson R; Large versus small femoral heads in metal-on-metal total hip arthroplasty, J Arthroplasty. Dec. 2004; 19(8 Suppl 3): Wang A, Yue S, Bobyn JD, et al: Surface characterization of metal-on-metal implants tested in a hip simulator. Wear 225, 1999: Fisher J, Ingham E, Stone MH, et al: Wear and debris generation in artificial hip joints. In: Reliability and Long-term Results of Ceramics in Orthopaedics. Sedel L, William G (eds), Stuttgart-New York, Thieme. 1999: Streicher RM, Semlitsch M, Schön R, et al: Metal-on-metal articulation for artificial hip joints: laboratory study and clinical results. Proceedings of the Institution of Mechanical Engineers, Part H 210, 1996: Tipper Jl, et al. Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloy used in metal-on-metal hip replacements. J Mat Sci: Mat Med. 1999; 10(6): Scholes SC, Unsworth A: Pin-on-plate studies on the effect of rotation on the wear of metal-on-metal samples. J Mat Sci Mater Med 12, 2001: St. John KR, Zardiackas LD, Poggie RA: Wear evaluation of cobalt-chromium alloy for use in a metalon- metal hip prosthesis. J. Biomed Mater Res 68B, 2004: Firkins PJ, Tipper JL, Saadatzadeh MR, et al: Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator. Biomed Mater Eng 11, 2001: Chan FW, Bobyn JD, Medley JB, et al. Wear and lubrication of metal-on-metal implants. Clin Orthop. 1999; 369: Jin ZM. Analysis of mixed lubrication mechanism in metal-on-metal hip joint replacements. Proc Instn Mech Engrs. 2002; 216 (part H): CeramTec AG, internal data on file Disclaimer This documentation is intended exclusively for physicians and is not intended for laypersons. Information on the products and procedures contained in this document is of a general nature and does not represent and does not constitute medical advice or recommendations. Because this information does not purport to constitute any diagnostic or therapeutic statement with regard to any individual medical case, each patient must be examined and advised individually, and this document does not replace the need for such examination and/or advice in whole or in part. Please refer to the package inserts for important product information, including, but not limited to, contraindications, warnings, precautions, and adverse effects. Copyright 2010 by Zimmer GmbH Printed in Switzerland Subject to change without notice Contact Contact your your Zimmer Zimmer representative representative or visit or visit us at us at Lit.No Ed c ZHUB +H /$101101K10Y
Clinically Proven Fiber Metal Material. Power to choose advanced bearing technologies to match patient demands
Trilogy IT Acetabular System Design Rationale 1 For orthopedic surgeons treating a wide range of patients, the Trilogy IT Acetabular System provides a clinically proven1-5 Fiber Metal Material and the
Metasul LDH Large Diameter Head
Metasul LDH Large Diameter Head Surgical Technique Metasul LDH Large Diameter Head Surgical Technique Enhancing Stability and Increasing Range of Motion Metasul LDH Large Diameter Head Surgical Technique
Why an Exactech Hip is Right for You
Why an Exactech Hip is Right for You Why do I need a total hip replacement? Which surgical approach is best for me? How long will it last? Which implant is right for me? Founded in 1985 by an orthopaedic
on-metal Hips: Device Mechanics and Failure Modes
1 Metal-on on-metal Hips: Device Mechanics and Failure Modes Steven M. Kurtz, Ph.D., and Richard Underwood, Ph.D. Exponent, Inc., and Drexel University NIH R01 AR47904 2 Contracts: DePuy Orthopaedics,
Acetabular Wedge Augment System
Orthopaedics Acetabular Wedge Augment System Stryker Hips. Implant with confidence. Restoration Acetabular Wedge Augment System Restoration Acetabular Wedge Augments, united with Tritanium, Trident, MDM
Zimmer Trabecular Metal Dental Implant
Zimmer Trabecular Metal Dental Implant TRABECULAR METAL MATERIAL: Designed to Enhance Secondary Stability Through Bone Ingrowth. Artistic Rendering osseoincorporation TRABECULAR METAL MATERIAL Designed
Taperloc Complete Hip System
Taperloc Complete Hip System One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized care to one patient. The science and art of medical care is to provide
The Right Choice. Exeter. total hip system
The Right Choice Exeter total hip system Exeter The Right Choice Anatomic Reconstruction Offset The objectives of total hip replacement are to: relieve pain increase mobility and function Achieving a correct
M 2 a-magnum. Design Rationale. Large Metal Articulation. Knees Hips Extremities Cement and Accessories PMI. Technology
M 2 a-magnum Large Metal Articulation Design Rationale Knees Hips Extremities Cement and Accessories PMI Technology M 2 a-magnum Large Metal Articulation History of Metal-on-Metal Early metal-on-metal
Total Hip Joint Replacement. A Patient s Guide
Total Hip Joint Replacement A Patient s Guide Don t Let Hip Pain Slow You Down What is a Hip Joint? Your joints are involved in almost every activity you do. Simple movements such as walking, bending,
TOTAL HIP REPLACEMENT FOR A LIFETIME: THE CEMENTLESS METAL ON METAL RECONSTRUCTION
Richard A. Sweet, M.D. Louisville Orthopaedic Clinic Louisville, KY TOTAL HIP REPLACEMENT FOR A LIFETIME: THE CEMENTLESS METAL ON METAL RECONSTRUCTION INTRODUCTION Total hip replacement surgery (THR) has
ReCap Product Rationale
FLH 155 01/09 Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom Tel. +44 (0)1656 655221 Fax. +44 (0)1656 645454 ReCap Product Rationale A complete resurfacing system
ABGII Cement Free Total Hip Replacement System
Cement Free Total Hip Replacement System Efficacy Innovation Cement Free Hip System The ABG Cement Free Hip System is one of the foremost ranges of cementless total hip replacement prosthesis. Used extensively
Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology
Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology Hips designed to fit the unique anatomies of men and women Independent control for a natural fit Simple, practical solutions for optimal restoration
VERILAST Technology for Hip Replacement Implants
VERILAST Technology for Hip Replacement Implants Surgeon Name Clinic Name Clinic Address Clinic i Address Phone Number Web Address Total Hip Replacement What Is VERILAST Hip Technology? OXINIUM Oxidized
The Crosslinked Ultra-high Molecular Weight Polyethylene
The Crosslinked Ultra-high Molecular Weight Polyethylene Fu-Wen Shen Ph.D. and Harry McKellop, Ph.D. The J Vernon Luck Orthop Research Center, Orthopaedic Hospital/University of California Los Angeles,
Metal-on-Metal Hip Systems
Meeting of the Orthopaedic and Rehabilitation Devices Advisory Panel June 27-28, 2012 Metal-on-Metal Hip Systems Center for Devices and Radiological Health U.S. Food and Drug Administration Meeting of
Answers to commonly asked questions from patients with metal-on-metal hip replacements / resurfacings. Contents
Answers to commonly asked questions from patients with metal-on-metal hip replacements / resurfacings John Skinner 1 and Alister Hart 2, Consultant Orthopaedic Surgeons and Directors of the London Implant
NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE. Health Technology Appraisal
NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE Health Technology Appraisal Total hip replacement and resurfacing arthroplasty for the treatment of pain or disability resulting from end stage arthritis
Accolade. System. Brochure. Achieving Perfect Balance. Cemented and Cementless Femoral Hip System
Accolade System Brochure Achieving Perfect Balance Cemented and Cementless Femoral Hip System Accolade Cemented Hip System Potential for Perfect Balance The Accolade C Femoral Component: A perfect balance
Patient Labeling Information System Description
Patient Labeling Information System Description The Trident Ceramic Acetabular System is an artificial hip replacement device that features a new, state-of-the-art ceramic-on-ceramic bearing couple. The
Zimmer Trilogy IT Acetabular System
1 Zimmer Trilogy IT Acetabular System Surgical Technique 2 Zimmer Trilogy IT Acetabular System Surgical Technique Device Description The Trilogy IT Shell is hemispherical in shape with an exterior of commercially
Rim Cracking of the Cross-Linked Longevity Polyethylene Acetabular Liner After Total Hip Arthroplasty
This is an enhanced PDF from The Journal of Bone and Joint Surgery The PDF of the article you requested follows this cover page. Rim Cracking of the Cross-Linked Longevity Polyethylene Acetabular Liner
The information contained in this document is intended for healthcare professionals only.
The information contained in this document is intended for healthcare professionals only. X3 Knee Technology The Next Generation in Highly Crosslinked Knee Polyethylene Innovation Matters As a pioneer
Modular Dual Mobility Acetabular Components: An Important Extension of a Proven Approach to Hip Instability
Modular Dual Mobility Acetabular Components: An Important Extension of a Proven Approach to Hip Instability Robert Wetzel, MD, Lalit Puri, MD, S. David Stulberg, MD Disclosure In accordance with ACCME
.URGENT DEVICE CORRECTION
zimmer.urgent DEVICE CORRECTION Zimmer, Inc. P.O. Box 706 Warsaw, IN 46561-0706 574.267.6131 www.zimmer.com July 22, 2008 Dear Surgeon: Since we last wrote to you in May 2008 regarding the Durom Acetabular
BONE PRESERVATION STEM
TRI-LOCK BONE PRESERVATION STEM Featuring GRIPTION Technology SURGICAL TECHNIQUE IMPLANT GEOMETRY Extending the TRI-LOCK Stem heritage The original TRI-LOCK Stem was introduced in 1981. This implant was
Trabecular Metal Technology
Trabecular Metal Technology TM The Best Thing Next To Bone. Introducing Trabecular Metal Material to implant dentistry. trabecular metal technology Trabecular Metal Technology is an innovative material
How To Make An Implant From A Metal That Is Like Bone
Trabecular Metal Technology The Best Thing Next to Bone Trabecular Metal Technology The Best Thing Next to Bone When you need a hip, knee, shoulder or spine implant, you want assurance that your implant
The information contained in this document is intended for healthcare professionals only.
The information contained in this document is intended for healthcare professionals only. UHR Universal Head Bipolar System T he Stryker Orthopaedics UHR Universal Head is a leader among bipolar component
Wear-contact analysis of hip implant coated with functionally graded material
2014; 1(7): 439-443 IJMRD 2014; 1(7): 439-443 www.allsubjectjournal.com Received: 13-12-2014 Accepted: 30-12-2014 e-issn: 2349-4182 p-issn: 2349-5979 Impact Factor: 3.762 Vinod Pallapu M. Tech Student
The Journal of Arthroplasty
The Journal of Arthroplasty 29 (2014) 219 224 Contents lists available at ScienceDirect The Journal of Arthroplasty journal homepage: www.arthroplastyjournal.org One-Component Revision of Failed Hip Resurfacing
Controversies around modern bearing surfaces in total joint replacement surgery
Page 44 SA Orthopaedic Journal Autumn 2013 Vol 12 No 1 Controversies around modern bearing surfaces in total joint replacement surgery PB Oosthuizen MBChB Senior Registrar CH Snyckers MBChB, Dip PEC(SA),
High-Flex Solutions for the MIS Era. Zimmer Unicompartmental High Flex Knee System
High-Flex Solutions for the MIS Era Zimmer Unicompartmental High Flex Knee System Zimmer Unicompartmental High Flex Knee Built On Success In today s health care environment, meeting patient demands means
frequently asked questions Knee and Hip Joint Replacement Technology
frequently asked questions Knee and Hip Joint Replacement Technology frequently asked questions Knee and Hip Joint Replacement Technology Recently, you may have seen advertisements from legal companies
Polyethylene Hip Resurfacing for Women
1 ORIGINAL ARTICLE Polyethylene Hip Resurfacing for Women James W. Pritchett MD Abstract Background: Since 1995, most hip resurfacing procedures have been performed using a metal-on-metal prosthesis with
i-polymers for i-arthroplasty New Polymer Technologies for HIP Arthroplasty
i-polymers for i-arthroplasty New Polymer Technologies for HIP Arthroplasty Leo Smit Business Director Implant Solutions Materials that belong to the body Total Hip Arthroplasty One of the largest successes
VEGA System. PS Knee Replacement Technology. Aesculap Orthopaedics
VEGA System PS Knee Replacement Technology Aesculap Orthopaedics A pivotal breakthrough in knee replacement. VEGA System PS Knee Replacement Technology Based on a patent-pending post-cam design that optimizes
Hip Resurfacing 2011 ORIGINAL ARTICLE. James W. Pritchett MD. Introduction. Abstract
1 ORIGINAL ARTICLE Hip Resurfacing 2011 James W. Pritchett MD Abstract In 1938 Marion Smith-Peterson placed a cobalt chromium cup on a reshaped femoral head to perform the first hip resurfacing. 15 Also,
ACCOLADE II. Orthopaedics. Femoral Hip System. Surgical Technique
ACCOLADE II Femoral Hip System Orthopaedics Surgical Technique Indications The indications for use of the total hip replacement prostheses include: Noninflammatory degenerative joint disease, including
Product overview and surgical technique
Product overview and surgical technique Overview Every patient moves differently 1 and their total hip replacement should be optimised to account for this. The orientation of the acetabular cup is one
Disappointing Short-Term Results With the DePuy ASR XL Metal-on-Metal Total Hip Arthroplasty
The Journal of Arthroplasty Vol. 27 No. 4 2012 Disappointing Short-Term Results With the DePuy ASR XL Metal-on-Metal Total Hip Arthroplasty Nicholas M. Bernthal, MD,* Paul C. Celestre, MD,* Alexandra I.
Artificial Hip Implants 2011
A Novel Elastic Squeeze Film Total Hip Replacement Stephen Boedo Department of Mechanical Engineering Rochester Institute of Technology Rochester, NY 14623 [email protected] John F. Booker Sibley School of
Introduction to Biomaterials in Orthopaedic Surgery
CHAPTER 1 Introduction to Biomaterials in Orthopaedic Surgery 1.1 Definition of Biomaterial A biomaterial is a material that interacts with human tissue and body fluids to treat, improve, or replace anatomical
Clinical Testing for Metal-on-Metal Prosthetic Wear and Tear
Clinical Testing for Metal-on-Metal Prosthetic Wear and Tear Frederick G. Strathmann, PhD, DABCC (CC, TC) February 8 th, 2013 Disclosures None Objectives Compare heavy metal analysis in synovial fluid
An Alternative Conservative Approach to Hip Reconstruction
Joint Implant Surgery & Research Foundation Chagrin Falls, Ohio, USA An Alternative Conservative Approach to Hip Reconstruction Craig S. Waller, MD* and Timothy McTighe, Dr. H.S. (hc)** Acknow ledgement:
Technology Breakthrough in Spinal Implants (Technical Insights)
Technology Breakthrough in Spinal Implants (Technical Insights) Biomaterial innovations is a growth factor for spinal implant market June 2014 Table of Contents Section Page Number Executive Summary 4
MDM. Surgical Technique. Modular Dual Mobility Acetabular System. Orthopaedics
MDM X3 Modular Dual Mobility Acetabular System Orthopaedics Surgical Technique Indications The indications for use of total hip replacement prostheses include: Non-inflammatory degenerative joint disease
Failure Mechanisms and Closed Reduction of a Constrained Tripolar Acetabular Liner
The Journal of Arthroplasty Vol. 24 No. 2 2009 Case Report Failure Mechanisms and Closed Reduction of a Constrained Tripolar Acetabular Liner William J. Robertson, MD, Christopher J. Mattern, MD/MBA, John
Zimmer Longevity Highly Cross-linked Polyethylene
Zimmer Longevity Highly Cross-linked Polyethylene Clinical Value Dossier April 9, 2012 TOC Clinical Value Dossier for Zimmer Longevity Highly Cross-linked Polyethylene 1 Executive Summary 7 2 Burden of
MDMTM. Surgical Technique. Modular Dual Mobility TM Acetabular System. Orthopaedics
MDMTM X3 Modular Dual Mobility TM Acetabular System Orthopaedics Surgical Technique Indications The indications for use of total hip replacement prostheses include: Non-inflammatory degenerative joint
PROCOTYL L. Acetabular Cup System
PROCOTYL L Acetabular Cup System S U R G I C A L T E C H N I Q U E Contents Chapter 2 3 Chapter 2 4 Chapter 3 5 5 6 7 9 0 2 2 4 4 5 Appendix A 6 6 7 7 7 8 8 8 Appendix B 9 Design Rationale Design Features
P REPLACEMENT SURGERY
P REPLACEMENT SURGERY DIRECT ANTERIOR APPROACH M I N I M I Z I N G R E C O V E R Y. M A X I M I Z I N G R E S U L T S. CENTER FOR MINIMAL INVASIVE JOINT SURGERY 2301 25TH STREET SOUTH FARGO ND 58103 701-241-9300
Photograph showing the components of an artificial total hip
Case Study 4 (CS4) Artificial Total Hip Replacement Learning Objectives After studying this case study, you should be able to do the following: 1. List and briefly explain six biocompatibility considerations
Disclosures. ! Consultant. ! Stryker. ! Smith and Nephew. Why Resurface? ! Save bone the day of surgery. ! No bone loss from stressshielding
Disclosures irmingham Hip Resurfacing Hip Resurfacing in 2015 Peter rooks MD, FRCS(C) Cleveland Clinic! Consultant! Stryker! Smith and Nephew HR Goals Why Resurface? Why Resurface?! Summarize benefits!
Posterior Referencing. Surgical Technique
Posterior Referencing Surgical Technique Posterior Referencing Surgical Technique INTRO Introduction Instrumentation Successful total knee arthroplasty depends in part on re-establishment of normal lower
The information contained in this document is intended for healthcare professionals only.
The information contained in this document is intended for healthcare professionals only. Orthopaedics Trident Acetabular System For Crossfire Polyethylene and Trident Alumina Ceramic Inserts With PSL
A Magazine Dedicated to Mass Torts Law. The Dangers of Metal-on-Metal Hips. Details of DePuy ASR Settlement Announced. www.langdonemison.
d3 Dangerous Drugs and Devices A Magazine Dedicated to Mass Torts Law The Dangers of Metal-on-Metal Hips Details of DePuy ASR Settlement Announced www.langdonemison.com Johnson & Johnson Agrees to Pay
Research Letter Biomimetic Composite-Metal Hip Resurfacing Implant
Research Letters in Materials Science Volume 2008, Article ID 368985, 4 pages doi:10.1155/2008/368985 Research Letter Biomimetic Composite-Metal Hip Resurfacing Implant Habiba Bougherara and Martin N.
Trident Acetabular System Hemispherical Surgical Protocol
Trident Acetabular System Surgical Protocol Trident Hemispherical Trident Acetabular System Hemispherical Surgical Protocol Trident Acetabular System Surgical Protocol Trident Acetabular System Hemispherical
Design surgeon list. Smith & Nephew thanks the following surgeons for their participation as part of the R3 system design team:
Surgical Technique Design surgeon list Smith & Nephew thanks the following surgeons for their participation as part of the R3 system design team: Robert Barrack, MD St. Louis, Missouri Robert Bourne, MD
Y O U R S U R G E O N S. choice of. implants F O R Y O U R S U R G E R Y
Y O U R S U R G E O N S choice of implants F O R Y O U R S U R G E R Y Y O U R S U R G E O N S choice of implants F O R Y O U R S U R G E R Y Your Surgeon Has Chosen the C 2 a-taper Acetabular System The
Graphic courtesy of DePuy Orthopaedics, Inc. HealthEast Joint Replacement Registry: 20 Year Report
Graphic courtesy of DePuy Orthopaedics, Inc. HealthEast Joint Replacement Registry: 20 Year Report HealthEast Joint Replacement Registry: 20 Year Report Foreword HealthEast Care System began the first
Randal S. Ford. ATTORNEY AT LAW (205) 752-4440 [email protected]. DePuy ASR Hip Implant Recall Fact Sheet
DePuy ASR Hip Implant Recall Fact Sheet Recalled Devices: ASR XL Acetabular System on the market since 2004, and sold worldwide. Dates of Implant: July 2003 to 2010 ASR Hip Resurfacing System on the market
Exeter X3 RimFit. Acetabular Cup Surgical Protocol
Exeter X3 RimFit Acetabular Cup Surgical Protocol 2 Exeter X3 RimFit Surgical Protocol Table of Contents Indications and Contraindications... 4 Introduction... 5 Surgical Protocol... 6 Step 1 - Pre-Operative
Metal-on-metal (MoM) total hip arthroplasty
S77 Metal-on-Metal Total Hip Arthroplasty Five- to 11-Year Follow-Up Vassilios S. Nikolaou, M.D., Ph.D., Alain Petit, Ph.D., Kevin Debiparshad, M.D., Olga L. Huk, M.D., M.Sc., David J. Zukor, M.D., and
MINI FRAGMENT SYSTEM. Instruments and implants for 1.5 mm, 2.0 mm, and 2.4 mm plate fixation PRODUCT OVERVIEW
MINI FRAGMENT SYSTEM Instruments and implants for 1.5 mm, 2.0 mm, and 2.4 mm plate fixation PRODUCT OVERVIEW TABLE OF CONTENTS INTRODUCTION Mini Fragment System 2 PRODUCT INFORMATION Plates 4 Screws 6
The information contained in this document is intended for healthcare professionals only.
The information contained in this document is intended for healthcare professionals only. Dall-Miles Cabling System Dall-Miles Recon and Trauma Cable System Trochanteric Reattachment Using the Trochanteric
it s time for rubber to meet the road
your total knee replacement surgery Steps to returning to a Lifestyle You Deserve it s time for rubber to meet the road AGAIN The knee is the largest joint in the body. The knee is made up of the lower
Metallurgical analysis of five failed cast cobalt-chromium-molybdenum alloy hip prostheses
Veterans Administration Journal of Rehabilitation Research and Development Vol. 23 No. 4 Pages 27-36 Metallurgical analysis of five failed cast cobalt-chromium-molybdenum alloy hip prostheses STEPHEN D.
Metal on Metal Hips. Total Hip Replacement. Total Hip Replacement
Metal on metal hips: Questions Metal on Metal Hips Jim Sullivan Why were metal on metal hips popular? Are all metal on metal hips the same? What are the problems with the ASR hip? What are the issues with
Performance evaluation of CLS Brevius Stem with Kinectiv Technology
Performance evaluation of CLS Brevius Stem with Kinectiv Technology Dirk Weidmann, Ronja Bruhn, Susanne Frei, Daniel Hertig, Xavier Langlois, Paul Hulme, PhD Zimmer GmbH Background A primary goal of total
Total Hip Replacement Hip replacement surgery, or arthroplasty, uses implants to resurface and replace the bones in the joint, re-creating the smooth gliding surfaces that were once intact. Hip replacement
Cormet Hip Resurfacing System
Cormet Hip Resurfacing System Patient Product Information 325 Corporate Drive Mahwah, NJ 07430 t: 1-888-STRYKER www.aboutstryker.com The information presented in this brochure is for educational purposes
NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE
NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE Overview Total hip replacement and resurfacing arthroplasty for treating pain or disability resulting from end stage arthritis of the hip (review of technology
Oxford Partial Knee. A Definitive Implant. Tibial Component. Anatomical shape for optimal bone coverage
Oxford Partial Knee Oxford Partial Knee A Definitive Implant With over 35 years clinical experience, the Oxford Partial Knee is the most widely used 1 and proven 2 partial knee system in the world. Tibial
IN THE FEDERAL COURT OF AUSTRALIA (FCA) NEW SOUTH WALES REGISTRY - FEDERAL COURT OF AUSTRALIA
IN THE FEDERAL COURT OF AUSTRALIA (FCA) NEW SOUTH WALES REGISTRY - FEDERAL COURT OF AUSTRALIA GENERAL DIVISION No: NSD213/2011 NOTICE OF FILING This document was filed electronically in the FEDERAL COURT
We have carefully reviewed your questions and the recent promotion for your program on the ABC website.
23 May 2014 Mr P Cronau Senior Producer, Four Corners, The ABC, GPO Box 9994, Sydney NSW 2001. Dear Mr Cronau, We have carefully reviewed your questions and the recent promotion for your program on the
Titanium Foam Implant
Titanium Foam Implant The Innovator 2 Move Implants is a Research & Development company which focuses on creating innovating products, not only to improve a product, but also the way of doing business.
Rejuvenate Total Hip System Surgical Protocol. Rejuvenate Modular Hip Stem Enhanced Stability 1 Proven Modularity 2 Intraoperative Flexibility
Rejuvenate Total Hip System Surgical Protocol Rejuvenate Modular Hip Stem Enhanced Stability 1 Proven Modularity 2 Intraoperative Flexibility Rejuvenate Total Hip System Surgical Protocol Table of Contents
TOTAL HIP REPLACEMENT: MODERN SURGERY FOR SEVERE ARTHRITIS OF THE HIP
TOTAL HIP REPLACEMENT: MODERN SURGERY FOR SEVERE ARTHRITIS OF THE HIP John T. Dearborn, M.D. and Alexander P. Sah, M.D. The Center for Joint Replacement Please read this pamphlet before you see me so that
Zimmer M/L Taper Hip Prosthesis. Surgical Technique
Zimmer M/L Taper Hip Prosthesis Surgical Technique Zimmer M/L Taper Hip Prosthesis 1 Zimmer M/L Taper Hip Prosthesis Surgical Technique Table of Contents Preoperative Planning 2 Determination of Leg Length
Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology. Surgical Technique
Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology Surgical Technique Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology 1 Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology Surgical
Exeter. Surgical Technique. V40 Stem Cement-in-Cement. Orthopaedics
Exeter Orthopaedics V40 Stem Cement-in-Cement Surgical Technique Exeter V40 Stem Cement-in-Cement Surgical Technique Table of Contents Indications and Contraindications...2 Warnings and Precautions...2
IN THE FEDERAL COURT OF AUSTRALIA (FCA) NEW SOUTH WALES REGISTRY - FEDERAL COURT OF AUSTRALIA
IN THE FEDERAL COURT OF AUSTRALIA (FCA) NEW SOUTH WALES REGISTRY - FEDERAL COURT OF AUSTRALIA GENERAL DIVISION No: NSD213/2011 NOTICE OF FILING This document was filed electronically in the FEDERAL COURT
BONE CEMENT. History, Performance, and Choice TECHNICAL MONOGRAPH
BONE CEMENT History, Performance, and Choice TECHNICAL MONOGRAPH HIStory PERFORMANCE CHOICE HISTORY PERFORMANCE CHOICE Started with DePuy Synthes Companies The Bone Cementing Story CMW Laboratories, now
Wear of metal-on-metal hip bearings: metallurgical considerations after hip simulator studies
Int J Artif Organs 2011; 34 ( 12) : 1155-1164 DOI: 10.5301/ijao.5000065 ORIGINAL ARTICLE Wear of metal-on-metal hip bearings: metallurgical considerations after hip simulator studies Saverio Affatato 1,
PERIPROSTHETIC IMPLANTS
PERIPROSTHETIC IMPLANTS PRODUCT OVERVIEW CLINICAL SOLUTIONS Periprosthetic fractures present unique challenges, such as how to gain fixation when the medullary canal is occupied. Special techniques and
Medical Device Alert. Device All metal-on-metal (MoM) hip replacements. Action by. CAS deadlines. Ref: MDA/2012/036 Issued: 25 June 2012 at 11:00
Medical Device Alert Issued: 25 June 2012 at 11:00 Device All metal-on-metal (MoM) hip replacements Problem The MHRA is issuing updated information and advice about the follow-up of implanted with metal-on-metal