1 LV switchgear Industry leading technology from Mardix The UK s leading provider of switchgear, power distribution and monitoring systems.

2 LV switchboards: detailed technology from Mardix Introduction As the UK s leader in high power switchboard solutions, Mardix has more than 40 years of cross sector experience. From hospitals to shopping centres, office developments to data centres, our knowledge and expertise is built into every product. Whether you require a 1250A modular switchboard or a 6300A ASTA certified L shaped bespoke switchboard, Mardix has a solution to meet your needs. Our uncompromising commitment to high build quality combines with our in house philosophy, which ensures that every switchboard is designed and manufactured to exacting specifications and is delivered on time, every time. A collaborative approach At Mardix we take ongoing product development very seriously. We have committed to extensive research and development and ASTA Type Testing programmes as part of our business investment. The results of this approach are demonstrated in the finished product; fully installed and tested LV switchboards with built-in benefits (Fig.01). We pride ourselves on assisting end users, consultants, and contractors through every step of the design, manufacturing, and installation processes, and are delighted to work with consultants from a project s inception. In the earliest design stages our input guarantees that any designs issued for tender are fit for purpose, commercially viable, and are of the required specification. We understand the need for specification compliant bids and requirements for value engineering during the tender process and have built excellent relationships with electrical contractors on this basis, offering a safe path rather than a badly engineered alternative. We stand by the principle that a cost effective Mardix quotation should be about more than just our bottom line price, it should be about added value for the client. Ongoing collaboration with all parties and valuable feedback from end users keeps us at the fore of switchgear technology. Our ability to convert client feedback into technological advances has been central to many new initiatives and products, not least our intelligent switchboards (iboards ) and intelligent Power Distribution Units (ipdus ) which have set the industry standard. Similarly, our Mardix LV switchboard design is 100% Mardix owned and has been developed in 3 key stages over many years. Our latest offering is the most technically advanced and feature rich offering to date and is only possible due to our in-house 3D solid modeling capability, which has introduced innovations not previously possible with 2D software. We spend a significant amount of time during the design process perfecting the top level assembly which is automatically checked for accuracy, clearance and zero clashing parts. The same attention to detail is witnessed in our manufacturing approach. All switchboards and PDUs are of fully welded construction for maximum rigidity and high tolerance not achievable with bolted flat pack assembly. Door seals remain flush fitting and Ingress Protection (IP) ratings are not compromised. An earthing arrangement running the full length of the switchboard and vertically into each cubicle section forms a high integrity earth bond against the welded enclosure. Whilst a welded, integral, high strength plinth completes the cubicle structure, which is then suitable for slab mounting or on a separate raised plinth assembly. An exacting cubicle fabrication process and a resilient powder coating in any RAL or BS4800 colour ensures the final product looks just as we intended. Key benefits ASTA certificates of Type Testing up to 6300A (100kA for 1sec) with unique ventilations systems designed, tested, and incorporated into higher power Mardix switchgear Thermal imaging capability as standard, with strategically positioned pre-punched grids for ease of access and enhanced surveying accuracy Forms of Separation up to Form 4 Type 7 with front and rear access designs Fully welded high strength Mardix cubicle system with high integrity earth bond, which is suitable for slab mounting or bolting onto underfloor plinthwork Standard Ingress Protection to IP31. Higher IP ratings are available, and all Mardix switchboards are suitable for mounting within GRP enclosures High and low level cable spreader boxes to facilitate glanding and termination of large cables All outer doors and busbar chambers are hinged for ease of access. Screw fix covers are not an acceptable alternative and will not be used Bespoke arrangements to meet specific width and height constraints Powder coated to any RAL or BS4800 colour. Our standard colour is BS A03 (light grey) with a semi-gloss smooth finish

3 Fig.01. A top level 3D solid model switchboard assembly. Fully welded construction Constructed from individually folded panels, which are fitted and welded together to form the superior Mardix cubicle system with maximum rigidity. Hinged doors and chambers Doors, busbar and cable chambers are all hinged for added safety. We do not use screw fix covers. Ventilation ASTA Type Tested natural and forced air-cooling assemblies are used on higher current rated switchboards Switchboard earthing Copper earth bars run along the entire length of the cubicles and drop vertically into the functional, busbars and chambers. Thermal imaging ports Designed by Mardix and fitted to all MCCB and fuse switch outer doors, our thermal imaging ports are CNC cluster punched directly into the steel. A tamper proof retained fastener mechanism allows the port to be opened to allow efficient and non-invasive thermal imaging. Cable spreader and transition boxes Higher current rating switchboards are fitted with boxes to facilitate glanding and termination of large cables. Transition boxes can be used where cables run perpendicular to the vertical plane of the switchboards.

4 LV switchboards: it s what s inside that really counts LV switchboards from Mardix have many unique internal features for improved resilience and performance (Fig.02). Safety is an absolute priority and inside the functional unit compartment it is clearly demonstrated in the mounting of the circuit breakers. Both the live and load sides of the switch are completely shrouded to prevent inadvertent contact with live parts, and copper connections to busbars are insulated and shrouded for added safety. In terms of separation, metallic barriers are used between each functional unit and also between functional and busbar chambers. This degree of separation provides further safety from live parts, and protects against a fault in one compartment propagating to an adjacent compartment. Horizontal and vertical busbar chambers are positioned and sized to ensure the busbars and connections can be accessed at any time during the life cycle of the switchboard. Each busbar compartment is provided with an outer door and a secondary captive thermal imaging screen. This method allows efficient and safe monitoring of busbars and connections with our infrared thermal imaging cameras. Mardix LV switchboards incorporate Air Circuit Breakers (ACBs), Moulded Case Circuit Breakers (MCCBs) and fuse switches. Typical brands used for these purposes are Schneider, Terasaki, ABB and Socomec, which are recognised as high integrity components. If you have width and height constraints in your plant room you may require double stacking of ACBs and high density stacking of MCCBs. Mardix have Type Tested these arrangements to ensure they perform under temperature rise. Forms of Separation for our LV switchboards are typically Form 4 Type 2, Form 4 Type 5, Form 4 Type 6 and Form 4 Type 7 (please refer to Forms of Separation section). We can accommodate all forms in front and rear access configurations and we always ensure glanding plates and cableways are the correct size and cable boxes can accept the specified cable sizes. Separate compartments are designated for metering, control and BMS terminals. Contacts for BMS are internally wired and taken to a BMS terminal rail with dedicated routes for the external cables. Protection fuses and control components are clearly labelled and cross referenced to our schematic drawings. Double marking system for all power connections For nearly a decade Mardix has implemented quality procedures to achieve zero tolerance of errors during busbar installation, and we always invest time in making sure we adhere to those quality procedures. Every connection is tightened with a torque wrench and then marked, initialled, dated, and signed with a coloured pen. A second, independent operative then subjects the same connection to the same procedure. Our Production Manager, Simon Hamer, comments, This system has moved us ever closer to our original objective of zero errors and every member of our site teams understands what a significant difference it has made to our business, and to levels of client satisfaction. It s an apparently simple process that offers reassurance whilst improving the end product. Example of double marking procedure. Key benefits All functional are protected against inadvertent contact with live parts. Custom made shrouds with laser profiled thermal imaging grids allow efficient thermal imaging of circuit breaker connections All connection points can be thermal imaged including busbar chambers and incoming/outgoing cable boxes All major brands of ACBs, MCCBs and fuse switches can be incorporated, including Schneider, Terasaki, ABB and Socomec Sealed CT chambers with connection links, insulation barriers and shorting links, built to the specification of all Regional Electricity Companies (REC) Integration of tuned and detuned Power Factor Correction (PFC) and Active Harmonic Filters (AHF) Type Tested arrangements for stacked ACBs, and high density stacking of MCCBs Separate compartments with fully labelled components and terminals for metering, control, and prewired BMS contacts Incorporation of protection relays, G59 protection, battery intertripping, Electronic Surge Protectors (ESP), Castell interlocking arrangements including solenoids and exchange boxes, temperature monitoring and large mimic panels Incorporation of HMI control panels, dual redundant PLC control philosophies, standard PLC control, auto-changeover systems and load shedding Incorporation of high end metering systems with waveform capture facility such as Schneider ION 7650 and ION Multifunction metering brands include Socomec, Autometers, Schneider. Energy metering to building regulations Part L2. See also the iboard and ipdu for our intelligent range of switchgear and PDUs

5 Fig.02. An intermediate 3D solid model switchboard assembly. Cable management systems Attention to detail doesn t stop at our outgoing connection boxes, cable ways are constructed to ensure cabling can be organised and strapped securely in place. Sealed REC CT chambers Mardix build CT chambers to all Regional Electricity Company specifications, ensuring our clients don t have any issue when the REC comes to terminate the incoming supplies. Fully shrouded functional Careful attention to detail and custom made shrouds with laser profiled thermal imaging slots provide protection against inadvertent contact with live parts, and allow for efficient thermal imaging of the circuit breaker. connections far large and multiple cables High strength busbar support assemblies are used to gland and terminate very large cables such as 500 mm 2 single core cables or multiple Steel Wired Amoured (SWA) cables per phase. Safety - insulated flexible busbars As standard, we only use insulated flexible connections on circuit breakers up to 630A. This Type Tested arrangement virtually eliminates the possibility of foreign objects settling between live conductors in the most inherently susceptible part of a switchboard.

6 Mardix busbar systems The new advanced Mardix busbar system offers space and cost savings and is rated up to 6300A (100kA for 1sec). Strip away all the other elements of the switchboard (see Fig.03) and we can see perhaps the most important element of a Mardix LV switchboard; our all new, Mardix owned, ASTA Type Tested busbar system, which is rated up to 6300A (100kA for 1 sec). Like many switchgear companies we used a proprietary busbar system, however, in 2006 we began to develop our new system, which we felt was required to enhance the Mardix cubicle system. During development we outlined various criteria that had to be met: Improved performance with the same cross sectional area of High Density, High Conductivity (HDHC) copper. Stronger busbar supports allowing higher fault ratings than previous possible. Increased cooling around horizontal and vertical busbar assemblies for both air natural and forced air cooling options. Vastly quicker assembly process within the tight spatial constraints of busbar chambers, which would ultimately slash time required onsite connecting LV switchboards. In 2008 we passed our first major test with the new Mardix system, which included a 4000A, 4 pole ACB, a 4000A 4 pole busbar and various outgoing circuit breakers. The switchboard performance exceeded our expectations and during temperature rise passed in an air natural configuration. This was due, in no small part, to the use of our all-new ventilation duct system. Following this early success we went on to achieve the holy grail of type testing at IPH in Berlin, including a heat rise test at 6300A in an air natural configuration. This achievement is believed to be a first on a global scale, and is testament to our ongoing commitment to improved switchgear performance. Commenting on the breakthrough, Mardix Director, Wayne Lewis said: This achievement is a very positive step forward for Mardix, and reflects the continued success of our ASTA Type Testing programme. We look forward to passing the benefits of this achievement on to our client base, including efficiencies in the switchboard assembly process. Mardix have invested 250K in the current ASTA Type Testing programme and will continue testing late into D solid modelling Every switchboard Mardix produces is designed in-house using 3D design expertise. Once the overall assembly design is complete, it is transferred to the Computer Aided Design/ Computer Aided Manufacture (CADCAM) area where the assembly is analysed and separated into - subassemblies - and parts of varying materials including steel, copper, aluminium, polycarbonates and plastics. All 3D parts are automatically developed into 2D flat parts and then converted into machine code. This code is then sent to the job libraries of the required machine whether that is a laser cutter, a CNC punch, or a press brake. This level of technology and automation means Mardix now consistently produces cost effective and efficient switchgear. Production Director Wayne Lewis explains the benefits of 3D modelling: Our assembly times have reduced dramatically which saves costs for the client, and the potential to have zero design errors has virtually eliminated incorrectly machined parts, mistakes, and rework which saves time and enables us to keep projects right on schedule. Mardix can offer cost effective modular LV switchboard solutions to fit your budget, with lead times from only 7 10 days depending on configuration. Key benefits All new 100% Mardix owned, ASTA Type Tested busbar system. Developed in-house since 2006, we have introduced new innovative features that benefit our clients through cost and space savings, and that speed up our LV switchboard assembly process ASTA tested up to 6300A (100kA for 1 sec). Our range of Type Test certificates allows a more flexible approach to busbar sizing, and associated cost savings can be passed onto our clients We have achieved cost savings through the full range of busbar assembly ratings. This ensures we remain competitive whilst still delivering the highest quality LV switchboards Innovative busbar connecting systems, easier access to the individual busbar supports, and much improved 3D assembly drawings have reduced fitting times by up to 30% 200% busbar requirements can be accommodated. (contact us for further details) Free issue busbar flanges, which can be problematic at the final stages of installation, are incorporated with ease using our 3D software. We can fit and test final connections as part of LV switchboard installation. Using our 3D views of complex busbar assemblies, including multiple corner sections and overhead busbar links, our customers benefit from enhanced visualisation, which also simplifies the design process

7 Fig.03. A 3D solid model complex busbar assembly. Innovative fishplate connections Fishplates are now much easier to install as they are accurately sized and positioned to improve access for torque wrenches. A unique Mardix fastening system reduces fixing time by up to 30% and both of these benefits have proved valuable to our onsite teams. Brand new busbar supports from Mardix The Mardix busbar system delivers increased performance and strength plus reduced manufacturing and assembly times. Complex busbar assemblies We understand plant room space constraints and manufacture irregular shaped boards to fit available space.

8 Forms of Separation All of our Forms of Separation are agreed between users and ourselves during specification. In order to protect against contact with live parts belonging to adjacent functional, and against the passage of solid foreign bodies from one unit within an assembly to an adjacent unit, we take great care to apply the most appropriate Forms of Separation to each solution we manufacture. Ranging from Form 2 Type 2 through to Form 4 Type 7 our Forms of Separation incorporate industry standard methods such as: non-metallic and metallic rigid barriers and partitions; glanding and termination chambers for cables; busbar separation; insulated coverings and shrouding; and external terminals. Each option is carefully considered and balanced to fit requirements and budgets, so you always know your equipment is well protected and cost effective. And, the probability of initiating arc faults is properly limited when you work with Mardix. We ve included the following pages as a quick and easy guide to the Forms of Separation offered on Mardix assemblies, and we ve included an area offering clarity on Ingress Protection (IP) ratings. 3D Solid model demonstrating all Forms of Separation. See next page for detailed information on each Form of Separation.

9 Form 2 Type 2 Metallic and non-metallic rigid barriers or partitions are used to achieve busbar separation, whilst terminals are separated from the busbars, but not from each other or functional. Form 4 Type 2 Metallic and non-metallic rigid barriers or partitions are used to achieve busbar separation. Cables are terminated in the same compartment as the functional unit, but are glanded elsewhere e.g. in a common cabling chamber. cable cables Form 4 Type 5 Metallic and non-metallic rigid barriers or partitions are used to achieve busbar separation. Terminals are external from the functional unit and insulated coverings such as PVC boots are used. Cables are glanded elsewhere e.g. in a common cabling chamber. cable cables Form 4 Type 6 All separation is achieved by metallic or non-metallic rigid barriers or partitions. Terminals are external from the functional unit compartment and rigid barriers or partitions are used to enclose them in their own compartment. Cables are glanded elsewhere e.g. in a common cabling chamber. cable cables Form 4 Type 7 All separation is achieved by metallic or non-metallic rigid barriers or partitions. Terminals are external from the functional unit compartment and rigid barriers or partitions are used to enclose them in their own compartment which features integral glanding facility. cable cables

10 Technical specifications A guide to the technical features behind Mardix LV switchgear. Enclosure Busbars and connections Mardix LV switchboards usually comprise one or more vertically mounted sections. The sections are generally slab mounted, however, options for mounting on underfloor/raised plinths can be accommodated. Our enclosures are formed from individually folded panels of Zintec sheet steel, which are fully welded and ground to provide clean lines and maximum rigidity. The Mardix high integrity earth bond is standard. An integral 150 mm plinth is then welded to the base of the cubicle to provide a solid support channel which enables the switchboard to be mounted on a separate underfloor plinth. Enclosure finish: Cabinets and doors are powder coated with RAL colours or BS4800 colours with a smooth finish whilst internal compartments feature RAL 9003 (white) with a ripple finish. Mardix busbar assemblies are ASTA certified up to 6300 Amperes (100kA for 1 sec). Busbars are air insulated. The neutral busbars have the same rating and cross sectional area as respective phase busbars. Individual riser busbars are suitably sized for the devices they serve, but are not necessary of the same rating as the main busbars. If required, busbars can be extendable at the ends of the switchboard in order to facilitate easy installation of future cubicle extension sections. Busbars are clad along their entire length. It is not be possible to come into contact with the busbars by opening any compartment doors, including busbar sections. At connection points, the busbars are punched with holes in each adjacent piece, which will then be connected together using fishplates, and suitably sized nuts, bolts, and washers. Edge clamping of busbars i.e. a no holed system is not used for Mardix switchboards. Tap-off connections from the main busbars to individual circuit breakers (up to 630A rating) are manufactured using insulated flexible copper links. This reduces the risk of short circuit at points on the busbar system that may be prone to high short circuit currents. All power connection points, including busbar joints are tightened to the correct torque in accordance with Mardix double marking standards. Functional and internal separation Control and BMS section Each functional unit is, in general, separated from each other. By opening the door of the respective functional unit e.g. an Air Circuit Breaker compartment, it isn t possible to inadvertently touch live parts. All exposed live parts are shrouded using proprietary or custom-made shrouds. In addition: Separation will be achieved in accordance with BSEN :1999. The exact Form of Separation e.g. Form 4 (6) will be as specified. Separation will generally meet the following conditions: Protection against contact with live parts belonging to adjacent functional Limitation of the probability of initiating arc faults Protection against the passing of solid foreign objects from one function unit to another Mardix internal separation will generally be achieved using rigid metallic barriers. Unless otherwise specified, busbars will be separated from functional This section houses the control, indication and protection components, including: Multi-function metering Specialist Protection Relays e.g. Restricted Earth Fault Relay LED indicators Pushbuttons and Keyswitches Transformer Temperature Relays Electronic Surge Protection Relays and Protection Fuses as applicable BMS and Control Terminals

11 Technical specifications Thermal imaging Doors and covers Labelling LV switchboards are designed and manufactured in-line with thermal imaging requirements. Thermal imaging ports are punched directly into the steel doors using CNC cluster punching. The ports are fitted with sliding captive covers, fixed and sealed to the door by security screws. A special tool is required to open the port. Polycarbonate custom-made shrouds are fitted over all connection points to prevent inadvertent touching of any live parts and to facilitate safe thermal imaging. The custom-made shrouds are manufactured from polycarbonate sheet, which is folded and tied to form a rigid barrier. Each barrier will be laser profiled with slots positioned in such a way to facilitate efficient thermal imaging of the connection point. Switchboard enclosures are IP31 unless otherwise specified. The switchboard has hinged doors, which cover the individual compartments and terminal chambers. 90-degree turn latches are used to lock each compartment and a special tool is required to open the doors. Mardix do not use screw fix external covers. All door hinges are high quality and of sufficient strength that doors stay aligned and square. Where applicable, doors are completed with polycarbonate viewing windows, sealed with rubber profiling strip. Engraved traffolite labels will be fitted to relevant doors and chambers. General labels black letters on white background Voltage warning labels black letters on yellow background General warning labels red letters on a white background All fuses and control components and associated connection terminals will be labelled using adhesive strip labelling. Ingress Protection ratings IP Codes classify the degrees of protection provided against intrusion of solid objects in electrical enclosures. This protection includes body parts such as hands and fingers, dust, accidental contact, and water. The standard aims to provide users with more detailed information than terms such as waterproof would. Digits are used to express conformity. As an example an ingress protection rating could be stated as IP31. Therefore the switchboard would be protected against solid objects larger than 2.5 mm and vertically falling water droplets. First characteristic numeral protected against solid bodies No protection against contact and ingress of objects Protected against solid bodies larger than 50 mm (eg. accidental contact with hand) Protected against solid bodies larger than 12 mm (eg. finger contact) Protected against solid bodies larger than 2.5 mm (eg. tools and wires) Protected against solid bodies larger then 1 mm (eg. fine tools, small wires) Protected against dust (no harmful deposits) Totally dust tight Second characteristic numeral protected against liquids No protection Protected against vertically falling water droplets (condensation) Protected against water droplets deflected at up to 15º from the vertical Protected against water spray at up to 60º from the vertical Protected against water spray from all directions Protected against low pressure water jets from all directions Protected against strong water jets and waves Protected against effects of temporary immersion Protected against effects of prolonged immersion under pressure

12 Get in touch now Call now on: to talk to us about how you can benefit from custom engineered switchgear at Mardix, or Delivering peace of mind! Worried about power consumption? Tailored service packages including emergency call out response, routine maintenance and servicing of non-mardix equipment. Mardix delivers integrated intelligent solutions for optimum energy efficiency, improved power quality, and ongoing critical power provision. 24/7/365 emergency assistance Emergency onsite engineers Telephone technical support Non-invasive maintenance Isolated maintenance Thermal image surveys Industry standard ipdu technology Power quality improvements Power trending procedures Citect Facilities and/or PowerLogic ION Enterprise Energy management to individual racks Integration with your management systems Call our Service Division now on Call our Monitoring Division now on t Mardix, Service Division, Westmorland Business Park, Kendal, Cumbria, LA9 6NS

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

GUIDE TO LV SWITCHGEAR & FORMS OF SEPARATION

GUIDE TO LV SWITCHGEAR & FORMS OF SEPARATION GUIDE TO LV SWITCHGEAR & FORMS OF SEPARATION CONTENTS INDEX...PAGE # PRODUCT EXAMPLES Mobile Battery Charging Unit... 3 PRODUCT EXAMPLES Form 4 Type 5 PDU - C/W Isolating Transformer... 3 PRODUCT EXAMPLES

More information

P System Cubicles. Certified for more safety

P System Cubicles. Certified for more safety P System Cubicles Prisma Plus LV Switchboards Certified for more safety Prisma Plus, an offer thought out for greater professionalism With the Prisma Plus P system, Schneider Electric proposes high-performance

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

Securing your electrical installations Prisma,

Securing your electrical installations Prisma, Securing your electrical installations Prisma, an optimised solution for type tested low voltage switchboards up to 3200 A Table of contents Developing installation safety 4 Prisma P * Electrical switchboards

More information

FAQs-Main switchboard design criteria

FAQs-Main switchboard design criteria FAQs-Main switchboard design criteria Q: What is the Australian standard for main switchboards? Current Australian standard is AS/NZS 3439.1: 2002 originating from IEC 60439. The new series of standard

More information

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS POWER DISTRIBUTION RACKS IN A MISSION CRITICAL SYSTEM MODULES IN A MISSION CRITICAL SYSTEM UPS Convertor Main Inverter Load Battery BPC UPS & BATTERY

More information

GE Power Controls. MiniFORM Switchboards

GE Power Controls. MiniFORM Switchboards GE Power Controls MiniFORM Switchboards MiniFORM MiniFORM MiniFORM switchboards Arrangement Modules Arrangement modules 1-6 6 Arrangement modules 7-12 7 Arrangement modules 12-14 8 Arrangement modules

More information

TriLine ASSEMBLY System PowerModules

TriLine ASSEMBLY System PowerModules 04 2012 TriLine ASSEMBLY System PowerModules TriLine ASSEMBLY system Contents Introduction The new modular system intelligence 2 Delivery formats 8 EDS PowerCon configuration software 10 Technical specifications

More information

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE 380/415/690 Volt AC 50/65/80/100 ka 1. Product Guide Low Voltage Motor Control Centre CONTSTRUCTION Continuous "poured in place" gasket

More information

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants Installation instructions Contents Key points of installation Before installation Installation Installation check

More information

Modis 25/32. Modular Switchboard Solution

Modis 25/32. Modular Switchboard Solution Modis 25/32 Modular Switchboard Solution Dorman Smith Switchgear Limited With over 130 years of experience in switchgear design and production Dorman Smith Switchgear Limited continues to provide high

More information

The Intelligent AX1 Switchgear for Medium Voltage

The Intelligent AX1 Switchgear for Medium Voltage The Intelligent AX1 Switchgear for Medium Voltage Leif Lundin, Manager of Research and Development, Division Medium Voltage and Compact Substations, ABB Distribution, Sweden Abstract The newly launched

More information

Secure your IT equipment with confidence... secure with NetClosure

Secure your IT equipment with confidence... secure with NetClosure Secure your IT equipment with confidence... secure with NetClosure SERVER CABINETS NetClosure s REM Series Server Cabinet is the ultimate solution designed and engineered for demanding data center environments.

More information

know-how Giant in distributing electricity for industry Prisma GK

know-how Giant in distributing electricity for industry Prisma GK Prisma GK Giant know-how in distributing electricity for industry Installation system up to 630A for electrical power distribution and circuit control. Prisma GK: technology and innovation for an IP55

More information

Industrial Process Plants. Residential & Commercial Buildings. Roads & Tunnels. Airports & Seaports

Industrial Process Plants. Residential & Commercial Buildings. Roads & Tunnels. Airports & Seaports APPLICATION TYPE TEST Industrial Process Plants ANT-V: Reliable, safety switchgear Hundreds of ANT s Switchboards have been supplied to industrial factories. ANT-V siwtchboards are designed, fabricated

More information

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation Basis of Design This section applies to the design relating to low voltage switchboards. Design Criteria UW Class N1 facilities main switchboards shall be rear accessible. The main, tie and feeder breakers

More information

Sample - No Commercial Use

Sample - No Commercial Use COMPLETE REVISION October 2010 Electrical PIP ELSSG01 Design and Fabrication of Low-Voltage Metal-Enclosed AC Power Circuit Breaker Switchgear PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort

More information

Cabinets 101: Configuring A Network Or Server Cabinet

Cabinets 101: Configuring A Network Or Server Cabinet Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What

More information

The complete guide to Low Voltage switchgear

The complete guide to Low Voltage switchgear The complete guide to Low Voltage switchgear The complete guide to low voltage switchgear Contents 4-7 Merlin Gerin LV Switchgear An introduction to the Merlin Gerin low voltage range of switchgear, and

More information

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems Safe energy distribution that meets the highest industrial requirements NATUS switchgear systems your advantages minimal use of insulant

More information

Low Voltage Switchboards The Best Technical Solution for Your Ship

Low Voltage Switchboards The Best Technical Solution for Your Ship The Best Technical Solution for Your Ship Wärtsilä SAM Electronics Optimal Power Distribution The uninterrupted supply of power to systems and consumers onboard modern ships is an extremly important matter.

More information

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels

More information

NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures

NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures NEW RANGE OF CABINETS DRIVIATM Innovation at your service THE GLOBAL SPECIALIST in electrical and digital building infrastructures Drivia true innovation The new electrical panel for the residential and

More information

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution Medium Voltage Products ZN1 12 kv arc-proof air-insulated switchgear for primary distribution ZN1 an innovative switchgear for power distribution requirements ABB ZN1 primary distribution switchgear is

More information

Which switchboards equip your building facilities for the future?

Which switchboards equip your building facilities for the future? Media Release SMB Electric Group October 2014 Which switchboards equip your building facilities for the future? From factories to shopping centres, from data centres to high-rise buildings, flexible switchboards

More information

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated

More information

Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated lightning impulse withstand voltage [kv] 75 125

Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated lightning impulse withstand voltage [kv] 75 125 Standards and Regulations IEC 62271-200 ; VDE 0671-200 ; BS EN 62271-200 Technical Data MC3-12 MC3-24 Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

SERVER ROOM CABINET INSTALLATION CONCEPTS

SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS ZPAS 169 EXAMPLES OF SERVER ROOMS PROJECTS WITH ZPAS CABINETS Data Box in the

More information

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon Type-Tested Power Distribution Board 8PT with Rear Busbars sivacon The Obvious Solution for Global Challenges SIVACON Type-testing is one of today s important issues for low-voltage technology and will

More information

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A s SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A Introduction The technical and descriptive information on the function, construction and selection of the new types of 3SE3 limit switches is

More information

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less. PART 1 - GENERAL SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less. RELATED SECTIONS Division 16 Section "Basic Electrical Materials and Methods" for general

More information

Distribution Boards & Consumer Units

Distribution Boards & Consumer Units Distribution Boards & Consumer Units Enclosures for system pro M compact Distribution Boards & Consumer Units Contents General 2/ Distribution Boards Mini Center compact Mounting kits for compact accessories

More information

e 2 ALPHA Medium Voltage Switchgear Data Sheet K-1.1.2 EN

e 2 ALPHA Medium Voltage Switchgear Data Sheet K-1.1.2 EN e 2 ALPHA Medium Voltage Switchgear Data Sheet K-1.1.2 EN We create ideas with power! ELEKTROMETAL ENERGETYKA SA is a new Polish company providing solutions for electrical power engineering. Our services

More information

Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada

Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada Whitepaper Modular Substation Cable Termination Design Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada Abstract The methods for cable penetrations into modular industrial substations are

More information

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars Presented By: Greg Pelster & Robert Schmid FFI Ferrie, Franzmann Industries LOW VOLTAGE SWITCHGEAR & LOW VOLTAGE

More information

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

ELECTRIC METERING COMMERCIAL & INDUSTRIAL ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS

More information

GUIDE TO FORMS OF SEPARATION

GUIDE TO FORMS OF SEPARATION GUIDE TO FORMS OF SEPARATION Low Voltage Switchgear and Controlgear Assemblies: BS EN 60439-1: 1994 (IEC 439-1) Including Amendment No1: 1995 The Electrical Installation Equipment Manufacturers' Association

More information

The following components are common to most cubicles; this example is an ABB HK cubicle.

The following components are common to most cubicles; this example is an ABB HK cubicle. 4.0 CIRCUIT BREAKER CUBICLE Learning Objectives The circuit breaker cubicle is the component of the switchgear that holds the circuit breaker, and the controls and cabling for the distribution system.

More information

ScottishPower Distribution Cables & Equipment. Metal Theft

ScottishPower Distribution Cables & Equipment. Metal Theft ScottishPower Distribution Cables & Equipment Metal Theft April 2012 As an aid to deterring to metal theft this booklet has been put together to help identify the types of utility power cables and associated

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

Installation Instructions

Installation Instructions READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:

More information

SAFETY ALERT SWITCHBOARD INTERNAL SEGREGATION AND IP RATING. May 2014 BACKGROUND

SAFETY ALERT SWITCHBOARD INTERNAL SEGREGATION AND IP RATING. May 2014 BACKGROUND SAFETY ALERT SWITCHBOARD INTERNAL SEGREGATION AND IP RATING May 2014 BACKGROUND There has been a recent serious incident involving a large arc event caused by material falling through an opening in a switchboard

More information

Contractors Guide Central Inverter System Installation

Contractors Guide Central Inverter System Installation Contractors Guide Central Inverter System Installation Step By Step Procedures 2,200 Watt/VA 6 Step Installation 1. Mount Bottom Cabinet 2. Mount Top Cabinet 3. Install Batteries 4. Install Conduit 5.

More information

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009 Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal

More information

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate: Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,

More information

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to

More information

Server Chassis and Triplet Hardware v1.0

Server Chassis and Triplet Hardware v1.0 Server Chassis and Triplet Hardware v1.0 Author: Steve Furuta, Mechanical Designer 1 Scope This document describes the technical specifications for the custom chassis used in Open Compute Project servers

More information

DATA CENTER RACK SYSTEMS: KEY CONSIDERATIONS IN TODAY S HIGH-DENSITY ENVIRONMENTS WHITEPAPER

DATA CENTER RACK SYSTEMS: KEY CONSIDERATIONS IN TODAY S HIGH-DENSITY ENVIRONMENTS WHITEPAPER DATA CENTER RACK SYSTEMS: KEY CONSIDERATIONS IN TODAY S HIGH-DENSITY ENVIRONMENTS WHITEPAPER EXECUTIVE SUMMARY Data center racks were once viewed as simple platforms in which to neatly stack equipment.

More information

SIVACON The Versatile Low-Voltage Switchboard

SIVACON The Versatile Low-Voltage Switchboard s SIVACON The Versatile Low-Voltage Switchboard Type-Tested Power Distribution Board 8PT The Obvious Solution for Global Challenges SIVACON Type testing in low-voltage switchgear is increasingly becoming

More information

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS STANDARD & ECONOMICAL BasicRack A complete low-cost, high-quality basic equipment management system. Design Six web channel holes per side allow

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

Rooflight INSTALLATION INSTRUCTIONS

Rooflight INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Rooflight These instructions should be used for: Installing Permanent Trickle Ventilation: Constructing & Waterproofing a Timber Upstand Curb: Installing & Waterproofing Proprietary

More information

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,

More information

19 DYNAmax Free Standing Server C A B I N E T s

19 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=600mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide

More information

Product Information 19 / 45HU Data-Center-Rack (Cabinet)

Product Information 19 / 45HU Data-Center-Rack (Cabinet) The Rosenberger-OSI Data-Center-Rack has been developed especially for FO patch distributors in Data Centers. In Data Centers the requirement for highest density becomes increasingly more important than

More information

How To Use A Ds340 (Dsp)

How To Use A Ds340 (Dsp) Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions

More information

DIGITUS Network & Server Cabinets. UNIQUE Series

DIGITUS Network & Server Cabinets. UNIQUE Series DIGITUS Network & Server Cabinets UNIQUE Series Benefits - Server Rack 4-Point locking system front door 3-point locking system rear door Swing handle lock with profile zylinder in front and rear door

More information

Installation, Operation and Maintenance Instructions. Uniflex ABB PTMV

Installation, Operation and Maintenance Instructions. Uniflex ABB PTMV Installation, Operation and Maintenance Instructions Uniflex ABB PTMV SAFETY FIRST! For safe and correct usage note the following recommendations: Only install switchgear and switchboards in enclosed rooms

More information

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002 INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002 NEW GAS INSULATED SWITCHGEAR (GIS) FOR ALL MEDIUM VOLTAGE APPLICATIONS H. Fink, ABB Calor Emag Mittelspannungs GmbH; M. Hyrenbach, ABB Calor

More information

19 DYNAmax Free Standing Server C A B I N E T s

19 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide

More information

MODEL HSR-007 Direct Drive Rolling Steel

MODEL HSR-007 Direct Drive Rolling Steel MODEL HSR-007 Direct Drive Rolling Steel 200 Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8 Tel: 866-792-9968 or 705-792-9968 Fax: 705-735-9564 www.tnrdoors.com email: info@tnrdoors.com Model HSR-007

More information

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB Reprint from Aluminium World 2009, Volume 2 Emirates Aluminium starts up World s first fully integrated power distribution system from ABB Emirates Aluminium (EMAL), a joint venture between Abu Dhabi s

More information

Switchgear and Metal-Enclosed Bus

Switchgear and Metal-Enclosed Bus Section 18 Switchgear and Metal-Enclosed Bus 180. SWITCHGEAR ASSEMBLIES 180A. General Requirements for All Switchgear. This rule covers general requirements for all switchgear. Examples of switchgear found

More information

Organizing and Managing Equipment Rooms

Organizing and Managing Equipment Rooms Organizing and Managing Equipment Rooms How you organize and maintain your equipment room can be just as important as maintaining the operating systems on the boxes themselves. Although many companies

More information

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

19 Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted. 19" Data Racks Attractive design and high quality are characteristic. Basic framework is welded from multiple bent metal plate, which assures great rigidity suitable for heavier equipment. All profile

More information

Linkeo 19" freestanding cabinets

Linkeo 19 freestanding cabinets 87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3

More information

Customized Server Cabinets

Customized Server Cabinets GOING GREEN WITH CUSTOMIZABLE CABINETS AND RACKS Designed to provide industry leading airflow, CyrusOne s cabinets and rack solutions promote optimal cooling and contribute to reduced power consumption.

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

Data Centre Solutions

Data Centre Solutions Issue 6 Data Centre Solutions RACKS POWER COOLING MONITORING SECURITY SERVICE & SUPPORT The simple route to the perfect data centre Data centres are complex systems. Software, hardware and IT infrastructure

More information

ATS Overhead Table Shelf System INSTRUCTION MANUAL

ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship

More information

Switchboard system. NorLine 800

Switchboard system. NorLine 800 Switchboard system NorLine 800 NorLine 800 SWITCHBOARD SYSTEM 2 NorLine 800 Switchboard system Table of contents Subject Page Table of contents 2 Overview 2-3 NorLine 800 technical specifications 4 Structural

More information

Section 10 Electric Switchboards: 0 Through 600 Volts

Section 10 Electric Switchboards: 0 Through 600 Volts Section 10 Electric Switchboards: 0 Through 600 Volts 10.1. Scope This section provides specific dimensions and details for service and meter equipment that is assembled by the manufacturer in freestanding,

More information

Installation. Smart-UPS VT MGE Galaxy 3500. Maintenance Bypass Panel. 10-40 kva 400 V

Installation. Smart-UPS VT MGE Galaxy 3500. Maintenance Bypass Panel. 10-40 kva 400 V Installation Smart-UPS VT MGE Galaxy 3500 Maintenance Bypass Panel 10-40 kva 400 V Contents Safety.................................................. 1 Save these instructions...................................

More information

5800 Temperature Sensor Cable Assembly

5800 Temperature Sensor Cable Assembly 5800 Temperature Sensor Cable Assembly Removal and Replacement Instruction Sheet #60-4702-070 Revision D, January 14, 2013 Overview The 5800 has two refrigeration temperature sensors, one attached to the

More information

TS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING

TS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING TORONTO TRANSPORTATION January 2012 TS 813 GROUNDING AND BONDING TABLE OF CONTENTS 1. DRAWINGS TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET

More information

Low Voltage Switchgear

Low Voltage Switchgear Arc Resistant Switchgear n Insulated and isolated bus n Separation barriers and top venting n Breaker shutters 12 SWITCHGEAR Arc resistant metal-enclosed low voltage switchgear is an optional product offering

More information

Secondary Unit Substations

Secondary Unit Substations 14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically

More information

Functional system Prisma P

Functional system Prisma P Enclosures and cubicles Functional system Prisma P Catalogue Prisma functional system Contents general page Index 2 Choice of switchboards 6 Prisma P functional system 11 b General presentation 12 b Installation

More information

Paper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation

Paper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation IOSR Journal of Engineering (IOSRJEN) ISSN (e): 2250-3021, ISSN (p): 2278-8719 Vol. 04, Issue 01 (January. 2014), V6 PP 01-12 www.iosrjen.org Paper on Basbar Trunking System for Electrical Supply to Industrial

More information

Containment Solutions

Containment Solutions Containment Solutions Improve cooling efficiency Separate hot and cold air streams Configured to meet density requirements Suitable for commercial and SCEC endorsed cabinets Available for retrofit to SRA

More information

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table

More information

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy Our brand A strong brand for strong products: The ENERGOLINE brand represents our product portfolio of INDUSTRIAL SWITCHGEAR SYSTEMS. Our products are characterized by a high degree of safety, flexibility

More information

Data Center Uninterrupted efficiency, guaranteed reliability and continuous modularity. ABB solutions always work.

Data Center Uninterrupted efficiency, guaranteed reliability and continuous modularity. ABB solutions always work. Data Center Uninterrupted efficiency, guaranteed reliability and continuous modularity. ABB solutions always work. Data security is first of all electrical Maximizing security while providing efficiency

More information

FEDERAL ELECTRICITY & WATER AUTHORITY

FEDERAL ELECTRICITY & WATER AUTHORITY UNITED ARAB EMIRATES FEDERAL ELECTRICITY & WATER AUTHORITY SPECIFICATION FOR 433 VOLTS SWITCHGEARS (LVAC BOARD) LVAC SWITCHBOARDS I N D E X CLAUSE TITLE 1. GENERAL 2. TEMPERATURE RISE 3. BUSBARS 4. CONSTRUCTION

More information

IEC 60439 >>> IEC 61439 GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

IEC 60439 >>> IEC 61439 GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES xl 3 configurable assemblies IEC 60439 >>> IEC 61439 GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES XL 3 configurable assemblies guide to migration from IEC 60439 to IEC 61439

More information

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D 12 - ELECTRIC SERVICE HANDBOOK SECTION D METER REQUIREMENTS This chapter gives you information on Central Lincoln s metering requirements. It's divided into three sections: General requirements This section

More information

SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM

SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM Pyrotenax SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM Contents Introduction This section provides an overview of general circuit design considerations and installation guidelines for a Pyrotenax System

More information

Electrical Safety Products

Electrical Safety Products Electrical Safety Products Trelleborg Electrical Safety Products A safe working environment is important in all industries, but in the electrical generation and supply industry, it is paramount. Trelleborg

More information

How To Build A T7 Rack For Information Technology

How To Build A T7 Rack For Information Technology THE NEXT GENERATION RACK FOR INFORMATION TECHNOLOGY THE RACK CABINET FOR INFORMATION TECHNOLOGY T7, THE HI-TECH HEART OF THE BLADESHELTER SYSTEM The real answer to the requirements of: Safety Versatility

More information

800 Communications Circuits

800 Communications Circuits ARTICLE 800 Communications Circuits INTRODUCTION TO ARTICLE 800 COMMUNICATIONS CIRCUITS This article has its roots in telephone technology. Consequently, it addresses telephone and related systems that

More information

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures SX 8 The SX range comprises 14 sizes of enclosure manufactured in either stainless steel or mild steel. 11 sizes are available in depths of 140 or 200mm and 8 sizes are available in depths of 140, 200

More information

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium

More information

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU George CURCANU, Constantin ILINCA, Ilie SBORA ICMET Craiova, Romania, Calea Bucuresti 144, phone:

More information

Advantages of Fixed Circuit Breaker Switchgear

Advantages of Fixed Circuit Breaker Switchgear Advantages of Fixed Circuit Breaker Switchgear by Lionel Mackay, EDF Energy, and Mike Adams, Schneider Electric Ltd Introduction The purpose of this paper is to review the advantages of fixed circuit breaker

More information

19" GERMANY EXPORT RACK QUALITY PRODUCT FOR THE BEST WORK NEW DESIGN CABLE MANAGEMENT PANEL WALL RACK CABINET 15 U VENTILATING FAN

19 GERMANY EXPORT RACK QUALITY PRODUCT FOR THE BEST WORK NEW DESIGN CABLE MANAGEMENT PANEL WALL RACK CABINET 15 U VENTILATING FAN NEW DESIGN CABLE MANAGEMENT PANEL WALL RACK CABINET 15 U VENTILATING FAN AC SOCKET STRIP (AC Power Distribution) BLANK PANELS x U OPEN RACK THERMOSTAD PANEL SET CABLE MANAGEMENT PANEL WITH COVER BAYING

More information