1 Ex 2.0 Rail-Mounted Terminal Block Systems Electronic Components for Applications in Hazardous Environments

2 4

3 Contents Over 50 years of innovations worldwide 1 The world of spring clamp termination systems 1 WAGO*SYSTEM Flexible Future-proof 2 Zone 1 Zone 2 Zone 0 Zone 1 General technical information for electrical equipment in hazardous environments 2 Zone 0 Zone 0 3 Ex e Rail-mounted terminal blocks 3 4 Ex e Terminal strips Ex e PCB terminal blocks Ex e Push-wire connectors for junction boxes 4 5 Ex i Terminal blocks (overview) 5 6 Matrix patchboards Terminal blocks for matrix patching 6 7 Shield (screen) connecting system 7 8 WAGO*SYSTEM 8 9 Rail-mounted terminal blocks with overvoltage protection function with coupler function 9 Index 10 Technical information Addresses 10

4 1 Over 0 50 Years of Innovations Since its foundation in 1951, WAGO Kontakttechnik GmbH, in Minden, has been pioneering terminal blocks and connectors with spring clamp termination technology. The carbon steel available at that time was barely suitable for manufacturing the first spring clamp terminal blocks (patent ). In addition, there were no test specifications to which spring clamp terminal blocks could have been tested or even approved. However, the idea was born and presented to the professional public at the Hanover Fair in Precision designed and manufactured, they not only guarantee a faster and easier connection but also offer a higher safety level since the contact quality is largely independent of the skill of the installer. The connected wire is clamped safely and permanently by the pre-programmed clamping force that automatically adjusts to the conductor cross section. WAGO spring pressure connection technologies became an industrial standard. The WAGO spring clamp terminal blocks are appreciated for their quick and easy operation, long-term durability and resistance to vibrations. As a result, maintenance-free operation leads to higher equipment availability. This benefits WAGO customers in competition worldwide. Today, WAGO is the worldwide leader of spring clamp connection systems and a component provider for decentralized automation in industry and building. More than 3700 WAGO employees worldwide are at the service of the customer, in development, production and marketing. Global availability of our products and services is guaranteed by 9 WAGO production sites 27 WAGO companies and more than 30 representations 1951 The first WAGO spring clamp: patent No WAGO push-wire connectors for juntion boxes. The original! 1977 Terminal blocks 0.08 mm 2 35 mm 2 with CAGE CLAMP 1995

5 Worldwide Main production sites Minden/Germany Headquarters, development, production Sondershausen/Germany Logistics centre, production Domdidier/Switzerland Production 2005 TOPJOB S installation terminal blocks 2003 TOPJOB S rail-mounted terminal blocks with CAGE CLAMP S Compact connectors for all types of wires WINSTA connector system

6 1 02 The Wide Variety of Applications U2fNDa HJq:;{[&4 U2fDaH U2KfD8 ajq:;{[&4 In worldwide railway traffic For more than 25 years, WAGO CAGE CLAMP technology has been ensuring trouble-free clamping connections in electrical installations in trams, underground railways, carriages, locomotives, all ICE generations, magnetic levitation train prototypes and the Shanghai Transrapid. In addition to the WAGO rail-mounted terminal blocks, terminal strips and connectors, the WAGO X-COM -SYSTEM,a modular, rail-mounted connector system has proved its worth during assembly, wiring and maintenance work. Moreover, it saves time and money. In power generation and distribution In 1955, terminal blocks with spring clamp connection were already being used in the control room of a nuclear energy center. Today, WAGO railmounted terminal blocks, terminal strips, PCB terminal blocks, matrix patchboards, connectors, interface modules and the WAGO I/O SYSTEM are constantly used in power generation, distribution and measuring installations. Absolute reliability during operatio, easy servicing and long-term durability; with installations that have to run for decades, these are connection requirements that are hard to find in any other application. In addition to that, it might be that the switchgear cabinet enclosure is the only protection against the weather, in outdoor installations for example. WAGO products with CAGE CLAMP connection meet all these requirements. In car manufacture WAGO products with CAGE CLAMP such as rail-mounted terminal blocks, terminal strips, the MULTI CONNECTION SYSTEM or the WAGO I/O SYSTEM contribute to a high availability of the production facilities: In switch or control cabinets in the press plant, in the bodyshell production, final assembly or in the paint shop. The vibration-proof and maintenance-free CAGE CLAMP provides double savings: wiring is done quickly and the routine maintenance work to control the clamping units is no longer necessary.

7 Years of Experience in Worldwide Applications U2fDa& Jq:;{[H4 YQ f:{[ rp ;:{4/ In shipbuilding, on and offshore installations Electrical installations in ships were among the first applications for WAGO rail-mounted terminal blocks with CAGE CLAMP connection. Vibrations are always present on ships. Time and again, these vibrations lead to loose connections in screw clamp terminal blocks since screws tend to untighten. This then requires time and cost intensive routine maintenance work. The CAGE CLAMP connection technology makes this work redundant. The WAGO I/O SYSTEM as well as WAGO terminal blocks and connectors are used successfully worldwide in the following: Sailing and motor boats, luxury liners, container and special vessels, high speed ferries, military catamarans, loading and container terminals, oil and gas platforms as well as different offshore applications. In building installation In 1974, WAGO revolutionized the wiring of distribution boxes in building installation with the WAGO push-wire connectors for junction boxes. Railmounted and installation multi-level terminal blocks with CAGE CLAMP connection, the WINSTA connector system and TOPJOB S rail-mounted terminal blocks with CAGE CLAMP S connection are other groundbreaking WAGO products that contribute to making building installation more economical and to increasing longterm durability of the installations. Special components, including radio modules that don t require an external power supply, add to the WAGO I/O SYSTEM and allow flexible and futureoriented decentralized building automation via LONWORKS or ETHERNET. The hardware is supported by intelligent software solutions to a universal programming environment in accordance with IEC In production and process automation Ex applications require special components. In addition to WAGO Ex railmounted terminal blocks with IECEx and ATEX 100a approvals, the WAGO I/O SYSTEM is also suitable for use in hazardous areas. For a long time, standard components have already been used in Zone 2 applications. Using intrinsic I/O modules it is possible to directly connect sensors and actuators from Zones 1 and 0 to Zone 2. The PROFIsafe modules are ideal for safety applications, which represent 10 20%, up to category 4 in accordance with EN or SIL 3 according to IEC and AK 6 (DIN V 19250). Standard, Ex and PROFIsafe components can be combined within one single fieldbus node. This means flexibility and economy.

8 1 WAGO Spring Clamp Termination Systems 04 Since the foundation of the company in 1951, terminal blocks and connectors equipped with innovative spring clamp termination technology have been manufactured by WAGO. Many of the spring clamp termination systems that have been developed and patented by Leaf spring clamping systems Clamping systems with leaf spring are available with or without operating device (push-button, screwdriver). These are simple push-wire connection systems, which are used for the connection of solid conductors with cross sections from 0.5 mm 2 to 6 mm 2. Conductors with lower stiffness solid wires with cross sections smaller than 0.5 mm 2 and flexible wires can also be connected to clamping systems equipped with an operating device, by actuating the clamp. Flexible conductors are only suitable to a limited extent (reduced rated current) for push-wire connection systems as these systems cannot bundle the wires. WAGO Spring Clamp Connection Technologies Leaf spring connection up to 2.5 mm 2 Push-wire connection up to 6 mm 2 IDC connection up to 1.0 mm 2 up to 1.5 mm 2

9 1 15 WAGO are now used worldwide, for example, in rail-mounted terminal blocks, in PCB terminal blocks, connectors, electronic modules, in the WAGO-I/O-SYSTEM and in other products. 1 CAGE CLAMP connection systems The original CAGE CLAMP is suitable for all types of wires with a rated cross section from AWG 28 to 2 (0.08 mm 2 to 35 mm 2 ). Both CAGE CLAMP Compact and POWER CLAMP complement the CAGE CLAMP connection. On the route to miniaturization, the CAGE CLAMP Compact connects wires up to 2.5 mm 2 (AWG 14) and the POWER CLAMP is the largest spring clamp allowing conductors from 35 mm 2 (AWG 2) to 95 mm 2 (AWG 3/0) to be wired. The CAGE CLAMP S connection offers all the advantages of the CAGE CLAMP in the cross section range from 0.25 mm 2 (AWG 22) to 25 mm 2 (AWG 4) with the additional benefit that "solid wires from 0.5 mm 2 (AWG 20) to 16 mm 2 (AWG 6) and flexible conductors with ferrules from 0.75 mm 2 (AWG 18) to 16 mm 2 (AWG 6) can be simply pushed in. CAGE CLAMP up to 35 mm 2 CAGE CLAMP Compact up to 2.5 mm 2 CAGE CLAMP S up to 25 mm 2 POWER CLAMP 25 mm 2 up to 95 mm 2

10 1 06 The advantages of the CAGE CLAMP Easy and obvious handling 3. Front entry 1. The screwdriver is inserted with a rocking motion to the stop The screwdriver is captivated, holding the CAGE CLAMP open, while the wire is inserted The screwdriver is withdrawn and the wire is automatically clamped. Side entry 4. Side entry: Operation of the CAGE CLAMP from the top, wire entry from the side. Screw terminal blocks are generally delivered with open clamping units. Once the conductor has been inserted, the clamping screw must be tightened using the correct torque. This requires high "visual judgement" on the part of the installer or the use of well set and well maintained torque screwdrivers. The operator may forget to tighten the screw after inserting the conductor. Therefore, the quality of the connection depends on the skill of the operator. Using the CAGE CLAMP connection, the conductor is inserted by opening the clamp with a standard screwdriver. Once the clamp is released, the fully inserted conductor is clamped safely and permanently by the pre-programmed clamping force that automatically adjusts to the conductor cross section. The contact quality is virtually independent of the operator's skill. With side-entry wiring, operating the CAGE CLAMP and inserting the conductor is done at a right angle to each other similar to the screw type connection. The widely used front-entry wiring, i.e. operation of the CAGE CLAMP and wire entry are executed parallel to each other from the front, makes protection against splaying of flexible conductor strands, such as the crimping of ferrules, unnecessary. Fast and maintenance-free Public wiring competitions have proven a reduction of the wiring time by 75 % when comparing manual wiring of screw-clamp terminal blocks with CAGE CLAMP terminal blocks. Even when powered screwdrivers are used for tightening the clamping screws, there is still a time advantage for the CAGE CLAMP terminal blocks. Pushin connection technology makes protection against splaying of flexible conductor strands unnecessary so that further cost reduction can be achieved. Furthermore, the maintenance-free CAGE CLAMP connection indirectly min. Average wiring time for 100 connections each. contributes to significant cost reduction. Due to maintenance-free operation, which results from longterm consistency and vibrationproof design, higher equipment availability can be achieved. This benefits WAGO customers in competion worldwide Screw-clamp terminal blocks CAGE CLAMP terminal blocks

11 Suitable for all copper conductors 1 conductor per clamping unit A universal system: suitable for all copper wires from AWG 26 (0.08 mm 2 ) up to AWG 2 1. solid, 2. stranded, 3. flexible 4. flexible wigh ferrule (gastight crimped) (35 mm 2 ). Special conductor preparation not necessary but possible. No load transfer to the insulation material Front-entry wiring makes it possible to place any number of CAGE CLAMP clamping units on a current bar. This has several advantages: a) It meets the safety requirement one conductor per clamping unit of the relevant standards, b) Conductors can be exchanged without interfering with the existing wiring, c) Additional connection points offer cost and space savings without the need for adjacent jumpers or additional terminal blocks and d) It offers spare capacity for future expansion. This can be practically implemented by using 3- and 4-conductor terminal blocks The CAGE CLAMP spring of the CAGE CLAMP connection secures itself to the current bar without support. During manufacturing, the springs are attached to the current bar and this self-contained assembly is then inserted into the insulated plastic housing. The separation of the mechanical from the electrical requirements allows the optimum choice of materials: high-grade stainless steel for the spring and high conductivity copper, tin-plated, for the current bar. This combination provides the best of both worlds. The WAGO CAGE CLAMP Clamping of the wire without damage through unique design CAGE CLAMP terminal block Pressure-blade, screw-type terminal block Screw-type terminal block with wire protection Screw-type terminal block without wire protection The CAGE CLAMP spring clamps the connected wire with pre-programmed clamping force that adjusts automatically to the conductor cross section. The flat clamping face of the spring presses the wire against the current bar without damaging the conductor. Any deformation or movement of the conductor is compensated, thus eliminating the risk of a loose connection. Each of the photos above show an 0.18 mm 2 and 1.5 mm 2 wire that was connected to both CAGE CLAMP as well as different screw-clamp connection systems. The tightening torque used for the screw-clamp terminal blocks was the torque specified by VDE In practical use this value is dependent upon the operator and generally higher. However, with the CAGE CLAMP connection, the clamping force automatically adjusts to the conductor cross section independent of the operator and is consistent everytime. Clamping force F in N 35 mm 2 An unlikely connection demonstrates the capability: a conductor of AWG 24 (0.2 mm 2 ) on the left and the nominal cross section of AWG 6 (16 mm 2 ) on the right in an AWG 6 (16 mm 2 ) terminal block. 1,5 mm 2 1,0 2,0 3,0 4,0 5,0 6,0 7,0 Displacement f in mm

12 1 08 Gastight contact area between conductor and current bar The corrosion-resistant CAGE CLAMP spring, manufactured of CrNi spring steel, presses the conductor into a defined contact zone against the slightly curved tin-plated current bar made of electrolytic copper. The conductor is embedded into the soft tin surface of the current bar with a high specific pressure. The contact area is hence protected permanently against corrosion. Due to this concentration of the clamping force in a defined contact area between conductor and current bar, the value of the contact pressure is comparable with that of screwclamp terminal blocks with the screws correctly tightened, as shown in the following example: Contact pressure P: Screw connection: CAGE CLAMP connection: P= Force F Area A P= 550 N 4 mm 2 = N/mm 2 55 N P= = N/mm mm 2 CAGE CLAMP connections are suitable for high current applications as well as for the transmission of low voltages and low currents in the mv and ma range for electronic and process control applications. Maintenance-free The maintenance-free operation results from the good long-term consistency of the electrical and mechanical characteristics of the terminal block - or more precisely the clamping unit. The voltage drop test allows quality assessment of the clamping unit under stress such as vibration, temperature change, and corrosive conditions, so that the gas tightness of the contact area can be checked. The long-term consistency of WAGO terminal blocks and connectors has been demonstrated both through the laboratory experiments of international approval agencies and from worldwide applications. As a result, their maintenance-free operation leads to higher equipment availability. This benefits WAGO customers in competition worldwide. Short circuit protected The short-circuit test according to IEC , paragraph 7.2.3, specifies that 120 A per square mm has to be applied for a period of one second, which means 4200 A for a 35 mm 2 terminal block. CAGE CLAMP connections pass this test without damage or impairment of their function. The figure shows an impractical test situation (in practice, fuses would switch off the current long before): The cur- rent through a 4 mm 2 terminal block is increased until the conductor glows red. Even under such test conditions, the terminal block remains undamaged.

13 Vibration and shock resistant The CAGE CLAMP spring itself has very little mass in relation to the high force it produces. Additionally, the CAGE CLAMP is mounted on the current bar and clamps the conductor in such a way that a favorable division of masses is obtained The interaction of these factors results in a connection which has high resistance to vibration and shock, as confirmed in many approval tests and in practical use. WAGO has tested the CAGE CLAMP connection for vibration up to 2000 Hz with accelerations up to 20 G. Independent agencies have tested and passed CAGE CLAMP for shock and vibration up to 2000 Hz with accelerations up to 109 G in each of three axes. The CAGE CLAMP connection also meets the vibration test requirements of VDE 0611 which incorporate a pull test while vibration is present. The UL "waggle" test also puts a rotational force on the wire while a pullout force is applied. Conductor retention forces Pull-out tests of different IEC / EN standards are used to determine the retention forces of conductors. The values specified by these standards are the same for both screw-clamp and spring-clamp terminal blocks. The table shows the pull-out forces required by IEC / EN / VDE 0611, part 1, rail-mounted terminal blocks for copper conductors and IEC / EN /VDE 0609, part 1, table 3 as well as IEC / EN , table 2, in comparison with the conductor retention forces measured on CAGE CLAMP terminal blocks. Rated cross section mm AWG/ MCM Conductor retention forces acc. to IEC N N Conductor retention forces measured on CAGE CLAMP terminal blocks /EN IEC /EN Solid Flexible Stranded N N N

14 1 100 FIELDBUS INDEPENDENT PROFIBUS INTERBUS ETHERNET TCP/IP DeviceNet CANopen CAL MODBUS \ II /O-LIGHTBUS Firewire CC-Link ETHERNET Controller Bit CPU programmable acc. to IEC /100 Mbit/s ETHERNET Controller programmable acc. to IEC Mbit/s SCALABLE SOLUTIONS ETHERNET coupler Modbus TCP 10/100 Mbit/s programming and commissioning with I/O-Pro and I/O-Check

15 Flexible Future-proof 1 11 I/O IPC Pentium MMX kompatible CPU optional Profibus Master MODULAR DOWN TO THE BIT 1 LOCAL TO OPERATION

16 control fieldbus

17 One solution many applications

18 2 0 General Technical Information for Electrical Equipment in Hazardous Environments Prerequisite for a potential explosion danger is the realization of an explosion endangered atmosphere. This can occur wherever inflammable gases or liquids are produced, processed, transported or stored. Such hazardous environment can form, for example, in chemical plants, refineries, tank farms, vehicles, sewage treatment plants, airports, grain mills or sea ports. GUIDELINE FOR THE BASIC PRINCIPLES OF EXPLOSION PROTECTION: General requirement The European Standard EN VDE classification 0170/0171 part 1 contains the general requirements for the construction and testing of electrical apparatus, which are determined for use in potentially explosive atmospheres. It has to be ensured, that this equipment does not cause an explosion of the surrounding atmosphere. In addition to the EN specification, the European Standards (see opposite page) which relate to specific standards of protection have to be considered. Electrical equipment Electrical equipment is any part which serves as a whole or in parts for the application of electrical energy. Amongs these are equipment for the production, transmission, distribution, storage, controlling and use of electrical energy, including telecommunication systems. Ex-components Ex-components are parts of an electrical equipment for hazardous environments and are marked with the symbol U. It is not allowed to use them alone in hazardous environments and, in case they should be used in these environments and in electrical equipment, an additional certificate is required. Types of ignition protection Only explosion protected equipment may be used in areas in which a dangerous, explosive atmosphere may still be expected despite the implementation of primary explosion protection measures. Electrical, explosion protected equipment can have various types of protection according to the construction regulations of the series of standards EN following (DIN VDE 0170/0171 Part 1 - following). The type of protection used by the manufacturer for apparatus essentially depends on the type and function of the apparatus. From a safety point of view, all standardized types of protection should be seen as being equal. Ignition protection n describes exclusively the use of explosion protected electrical components in zone 2. This zone encompasses areas where explosive atmospheres can only be expected to occur rarely or short-term. It represents the transition between the area of zone 1, which requires an explosion protection and safe area in which for instance welding is allowed at any time. Regulations covering these electrical components are being prepared on a world-wide scale. The standard EN allows electrical component manufacturers to obtain certificates from the corresponding authorities for instance KEMA in the Netherlands or the PTB in Germany, certifying that the tested components meet the above mentioned standards draft. Type "n" ignition protection additionally requires electrical components to be marked with the following extended identification: A non spark generating (function modules without relay /without switches) AC spark generating, contacts protected by seals (function modules with relays /without switches) L limited energy (function modules with switch) The table on the opposite page shows an overview of the standardized types of ignition protection and describes their basic principle as well as usual applications.

19 2 1 Ignition protection types Symbol Standard Explanation Application area o EN Oil immersed apparatus: Zone Electrical equipment or parts of same immersed in oil. p IEC Pressurized apparatus: Zone EN The ingress of the surrounding (explosive) atmosphere into the housing of electrical equipment is avoided by keeping the ignition protection gas inside under pressure. 2 q EN Powder filled apparatus: Zone Filling of the electrical equipment housing with fine grain sand prevents the ignition of a surrounding explosive atmosphere by an electric arc generated in the housing. d IEC Flameproof enclosure: Zone EN Equipment which could ignite an explosive atmosphere is encapsulated in a housing which can resist an explosion pressure within the housing. e IEC Increased safety: Zone EN Measures have been undertaken in order to achieve an increased degree of safety by the avoidance of inadmissibly high temperatures and the creation of sparks or electric arcs. i IEC Intrinsic safety: Zone EN Current circuit following in which no sparks or special thermal effects can occur and cause testing an ignition of a certain explosive zone 0 atmosphere. n IEC Non-sparking: Zone 2 EN Electrical equipment of group II for use in areas in which an explosive mixture of gas, vapor or mist is unlikely to occur during normal operation and if it does it will be for a short period. m IEC Cast encapsulation: Zone EN Dangerous electrical equipment is embedded in a cast mass. This corresponds approximately to the known special protection type Ex s. IEC Intrinsically safe electrical systems Zone EN Assembly of interconnected electrical equipment following in which the circuits intended for use, special as a whole or in part, in hazardous environments testing are intrinsically safe. It is documented zone 0 accordingly in the system description. IEC / TS FISCO standard Electrical apparatus for explosive gas atmospheres - Part 27: Fieldbus intrinsically safe concept (FISCO) and Fieldbus non-incendive concept (FNICO).

20 2 2 Continued General Technical Information for Electrical Equipment in Hazardous Environments Hazardous environments Hazardous environments are areas in which the atmosphere may become explosive. Explosive atmosphere is defined as a mixture of ignitable substances in the form of gases, apors or mixtures with air under atmospheric conditions in critically mixed ratios such that excessive high temperature, arcs or sparks may cause an explosion. According to EN , endangered areas are classified into zones according to the probability of the existence of a dangerous explosion prone atmosphere as follows: ➊ Zone 2 ➊ Areas explosion endangered as a result of combustible gases, vapours or mist Zone 0 encompasses areas in which an explosive gas/air mixture is continuously present or present for long periods. Zone 1 encompasses areas in which an explosive mixture can occur during normal operation. Zone 1 Zone 0 Zone 0 Zone 0 Zone 1 Zone 2 encompasses areas in which an explosive mixture is unlikely to occur under normal operation and if it does it will be for a short period. ➋ Zone 22 ➋ Areas explosion endangered due to combustible dust Zone 20 Area in which an explosive mixture in the form of dust in air is continuously present or present for long periods. Dust deposits of a known thickness or of an excessive thickness may build up. Dust deposits alone are not synonymous with Zone 20. Zone 21 Zone 21 Area in which an explosive mixture in the form of dust in air can occur during normal operation. Deposits of combustible dust exist in general. Zone 20 Zone 22 Area in which an explosive mixture in the form of dust in air is unlikely to occur during normal operation and if it does it will be for a short period or in which deposits of combustible dust exist.

21 The specification EN defines two groups of electrical equipment for hazardous environments: Group l: Electrical equipment for mines. Group ll: Electrical equipment for hazardous environments other than mines. This group is further subdivided by pertinent combustible gases in the environment. Subdivision IIA, IIB and IIC take into account that different materials/substances/gases have various ignition energy characteristic values. For this reason the three subgroups are assigned representative types of gases: IIA Propane IIB Ethylene IIC Hydrogen Publication of the WBK Mining Authority of March Quotation:... terminal blocks for which the type of protection EEx e ll has been certified will also be accepted for use in group I Electrical equipment of the type of protection Increased safety e. The table shows a comparison between the existing practice according to ElexV, DIN VDE and the new EN : Group II This statement can also be found in point 12 of the EC Examination Certificate stating that terminal blocks are approved for Group I as well as for Group II. Temperature Max. surface class temperature C T1 450 T2 300 T3 200 T4 135 T5 100 T6 85 Depending on the maximum surface temperature of the equipment, the electrical equipment of group ll is defined in temperature classes T1 up to T 6. The ambient temperature, which has to be considered, is fixed at 40 C (104 F). (Modifications of this value are possible under certain conditions) Terminal blocks for the type of protection lncreased safety e are generally classed in T6. When using terminal blocks in equipment of temperature class T1 up to T 5 it has to be ensured, that the highest temperature on the insulating parts does not exceed 85 C (185 F). The highest measured temperature rise on the surface of the equipment shall not exceed 40 K. The resistance to heat of the insulating material shall at least be 20 C (68 F) above the highest operating temperature. Minimum ignition energy of representative types of gases: Explosion group I IIA IIB IIC Gas Methane Propane Ethylene Hydrogen Ignition energy Category Type of Adequate Comparable with New acc. to protection safety with existing practice EN Ex atmosphere highest 2 protection Group II, Zone 0 is very probable, measures Zone 0 Zone 20 dust in air 2 errors Zone 10 2 From time to time increased equipment Group II, Zone 1 Ex atmosphere failure Zone 1 Zone 21 or error 3 Low probability of normal trouble-free Group II, Zone 2 Ex atmosphere, operation Zone 2 Zone 22 settled dust Zone 11 The resistance to low temperature is sufficient if the insulating material withstands a 24-hour storage at a temperature of up to minus 60 C ( 76 F) without destroying this type of protection. Specific requirements Increased safety EEx e The European Standard EN VDE 0170/0171 part 6 contains the special requirements for the construction and testing of electrical equipment for the type of protection Increased safety e, which are intended for use in explosive atmospheres. This specification is a supplement to EN and relates to such equipment or parts thereof, which do not produce arcs, sparks or dangerous temperatures under normal operating conditions. This standard describes special measures, which have to be observed to obtain a safety degree according to the type of protection - Increased safety e. Paragraph 4.2 Terminal blocks for external conductors relates to electrical equipment, such as railmounted terminal blocks. The following are the most important design requirements for terminal blocks for external electrical conductors: They shall be sufficiently large to permit the reliable connection of external conductors with cross section of at least the size related to the nominal current of the equipment; they must be protected against selfloosening and designed in such a way that the external conductors cannot slip out of their clamping units; they must be designed in such a way that sufficient contact pressure is ensured without damaging the conductors; their design must ensure that the contact pressure does not change with temperature cycling; for the connection of stranded conductors they must be designed with a spring connecting link; terminal blocks for conductor cross section up to 4 mm 2 /AWG 12 shall be so designed that smaller conductor cross sections may be connected safely

The range of rail-mounted terminal blocks. for a perfect electrical installation.

The range of rail-mounted terminal blocks. for a perfect electrical installation. The range of rail-mounted terminal blocks for a perfect electrical installation. The range of rail-mounted terminal blocks for a perfect electrical installation. The new standard for rail-mounted terminal

More information

picomax The Pluggable Connection System

picomax The Pluggable Connection System picomax The Pluggable Connection System TECHNOLOGY THIS SPECIALIZED CAN T MEET ALL REQUIREMENTS. YES IT CAN. CONTENTS picomax Pin spacing: 3. mm/0.138 in;.0 mm/0.197 in; 7. mm/0.29 in Versatile Pluggable

More information

Making sense of Intrinsic Safety and Intrinsically Safe Tools

Making sense of Intrinsic Safety and Intrinsically Safe Tools Making sense of Intrinsic Safety and Intrinsically Safe Tools What is Intrinsically Safe? Intrinsic safety is a protection standard employed in potentially explosive atmospheres. Devices that are certified

More information

The Rail-Mounted Terminal Block System

The Rail-Mounted Terminal Block System The Rail-Mounted Terminal Block System 2 The Industry s Largest Portfolio for Industrial, Building and Transportation Applications Industry s widest range of conductor sizes: 0.14 95 mm 2 (AWG 4/0 24)

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

distributing & controlling system solutions

distributing & controlling system solutions distributing & controlling system solutions your safety our reality Users > Oil and gas industry production storage transport > Petrochemical industry > Chemical industry > Pharmaceutical industry > Food

More information

Terminal Boxes Series 8146

Terminal Boxes Series 8146 Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

Hazardous Location. Products and Applications

Hazardous Location. Products and Applications Hazardous Location Products and Applications Fieldbus-Independent I/O for Hazardous Areas! The WAGO-I/O-SYSTEM 750 WAGO-I/O-SYSTEM Automation Independent Compact, flexible & modular: Most compact, fieldbus-independent

More information

Instructions for Safe Use

Instructions for Safe Use Instructions for Safe Use (Certification N:o VTT 08 ATEX 029) Thank you for choosing Slam Trans portable transformer for your job site. Purpose of this manual is to provide you all the necessary safety

More information

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment

More information

Spring Cage Feed-Through Terminal Blocks ST

Spring Cage Feed-Through Terminal Blocks ST Spring Cage Feed-Through Terminal Blocks ST The product family ST with the new spring cage system "mini spring" is extremely space-saving. Space is saved thanks to a clearly smaller spring system without

More information

Explosion proof enclosures

Explosion proof enclosures 1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without

More information

SEISMIC VELOCITY TRANSDUCER T1-40

SEISMIC VELOCITY TRANSDUCER T1-40 SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female

More information

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket Technical Datasheet SNK636D00 Catalogue Page SNK636S00 ZS-SF-T Screw Clamp Terminal Blocks For x 0 and x fuses - with test socket - Protect your circuit with x and x0 fuse terminal blocks (fuse not supplied

More information

Electrical Equipment in Hazardous Areas: Field Inspections

Electrical Equipment in Hazardous Areas: Field Inspections Electrical Equipment in Hazardous Areas: Field Inspections Bill Rankin Electrical Engineer / Senior Electrical Inspector Abstract Electrical equipment and installations that fall within explosive gas atmospheres

More information

SMD Terminal Blocks with Push-Buttons

SMD Terminal Blocks with Push-Buttons SMD Terminal Blocks with Push-Buttons SMD Terminal Blocks Small is Big WAGO s new SMD Terminal Blocks provide push-button termination for conductors 0. 0.75 mm/awg 4 18 (060 Series) and 0.5 1.5 mm/awg

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

PCB TERMINAL BLOCKS. Product Overview

PCB TERMINAL BLOCKS. Product Overview PCB TERMINAL BLOCKS Product Overview AT A GLANCE: THE ENTIRE RANGE Variants: Pin pacing: Terminal blocks, terminal strips (double-, triple-, quadruple-deck terminal strips), disconnect terminal blocks

More information

ZS25 Screw Clamp Terminal Blocks Feed-through

ZS25 Screw Clamp Terminal Blocks Feed-through Technical Datasheet SNK668D0 Catalogue Page SNK678S0 ZS Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to mm² AWG in just mm 0.47 in spacing. SNK68V004 SNK004F0000 D CAD

More information

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket Technical Datasheet SNK64D00 Catalogue Page SNK64S00 ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket - Ease your test operations with the built-in test sockets, - Screwdriver

More information

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357 Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism

More information

Ex q Powder Filling. This is a technique primarily used for oil filled switch-gear. The spark is formed under oil and venting is controlled.

Ex q Powder Filling. This is a technique primarily used for oil filled switch-gear. The spark is formed under oil and venting is controlled. Methods of explosion protection for electrical equipment Flammable atmospheres can be ignited by sparks or not surfaces arising from the use of electrical power. Other possible sources of ignition are

More information

David O Brien, CMP Products (David.OBrien@cmp-products.com)

David O Brien, CMP Products (David.OBrien@cmp-products.com) David O Brien, CMP Products (David.OBrien@cmp-products.com) 1) Main Function of Cable Glands 2) Common Issues with Cable Glands 3) Compliance / Standards, changing times 4) How do we select Cable Glands?

More information

HAZARDOUS AREA TECHNICAL GUIDE

HAZARDOUS AREA TECHNICAL GUIDE Page 1 HAZARDOUS AREA TECHNICAL GUIDE The Redapt Hazardous Area Technical Guide provides an overview for the design and use of equipment used within potentially explosive atmospheres created by gases,

More information

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, Flameproof Enclosure Series 8264. www.stahl. > Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The

More information

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL PRODUCT NAME: CP/PB -150- EXPLOSION-PROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH SAS-12-CP-PB150-TM REV01 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BOTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** FM 3046039 Class I Div 1, Groups A, B, C and D Class II Div 1, Groups E, F and G; Class III Class I, Zone 0, AEx ia IIC Ga, Ga/Gb, Gb Document ID:

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

2.12. page 223 2.12. Products for Explosion hazardous Environment

2.12. page 223 2.12. Products for Explosion hazardous Environment 2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available

More information

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade Technical Datasheet SNK646D00 Catalogue Page SNK646S00 ZS6-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver,

More information

Process Automation. Food

Process Automation. Food Process Automation Food Contents WAGO Process Automation 4-5 WAGO-I/O-SYSTEM 750 6-7 WAGO SPEEDWAY 767 8-9 TO-PASS Telecontrol Solutions 10-11 JUMPFLEX, 857 Series 12-13 TOPJOB S Rail-Mounted Terminal

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS) MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed

More information

Automation Solutions. LÜTZE LCOS empty housing for Industrial Automation

Automation Solutions. LÜTZE LCOS empty housing for Industrial Automation Automation Solutions LÜTZE LCOS empty housing for Industrial Automation Open, modular, universal: The new intelligent electronic housing LÜTZE LCOS Flexible: Use of the housing as a standalone solution

More information

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006 BETAtrans Cables and Systems for Rolling Stock. Edition 2006 Info Consulting and Sales By Phone To ask for Information or to place an order please use the following number: +49 (0)9172-6844-11 By Fax For

More information

Solenoid Valve Island Type 3965

Solenoid Valve Island Type 3965 Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

white paper Ferrules: Your Best Insurance Against Costly Connection Failure Executive Summary

white paper Ferrules: Your Best Insurance Against Costly Connection Failure Executive Summary Ferrules: Your Best Insurance Against Costly Connection Failure white paper Executive Summary Thanks to its superior flexibility, longer flex life*, and resistance to vibration, insulated stranded wire

More information

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6

More information

How To Protect An Explosion

How To Protect An Explosion The basics of explosion protection preface It is a fact that gases, vapours and mists escape during the production, processing, transportation and storage of flammable substances in the chemical and petrochemical

More information

Fire Alarm System Accessories

Fire Alarm System Accessories Approved by APPROVED Fire Alarm System Accessories FM Approved* Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

Operating Instructions

Operating Instructions Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4

More information

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS . HARTING RJ INDUSTRIAL ETHERNET CONNECTORS Ethernet is is coming up to standard industrial interface. Therefore, automation devices such as controllers, sensors and actuators feature possess on one or

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

MNS is Switchgear System Technical Overview

MNS is Switchgear System Technical Overview Switchgear System Technical Overview Innovative Design ABB s innovative MNS is concept combines the long term experience, energy efficiency, grid reliability and industrial productivity of the well-known

More information

Powermate Range Pitch 7.62

Powermate Range Pitch 7.62 owermate Range itch 7.62 in headers Socket connectors CB connection Solder connection SV 7.62/90 500 V / 43 A SV 7.62/180 500 V / 41 A.2.4 Cable connection Clamping yoke connection Tension clamp connection

More information

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures SX 8 The SX range comprises 14 sizes of enclosure manufactured in either stainless steel or mild steel. 11 sizes are available in depths of 140 or 200mm and 8 sizes are available in depths of 140, 200

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

Explosion Protected White Paper Series #1: Imaging Challenges in Explosive Environments

Explosion Protected White Paper Series #1: Imaging Challenges in Explosive Environments Video Systems Explosion Protected White Paper Series Imaging Challenges in Explosive Environments Explosion Protected White Paper Series #1: Imaging Challenges in Explosive Environments Introduction Extraordinary

More information

Terminal Box. Specifications TNCN

Terminal Box. Specifications TNCN Terminal box The /TNCC range comprises many standard sizes of enclosures manufactured in stainless steel 316L for maximum environmental protection. The main body is manufactured from minimum 1,5 mm sheet

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element

More information

Connection technology from ifm.

Connection technology from ifm. Connection technology from ifm. Connection technology www.ifm.com/gb/connect WARRANTY years on ifm products The right choice for reliable connections. ecolink M. Cannot be overtightened! Due to the special

More information

NI 9423. NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

NI 9423. NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module DATASHEET NI 9423 8-Channel Sinking Digital Input Module 8-channel, 100 µs digital input 24 V logic, sinking digital input Compatible with NI CompactDAQ counters 250 Vrms, CAT II isolation 10-position

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,

More information

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Threaded Resistance Thermometers Model TR10-D, Miniature Design Electrical Temperature Measurement Threaded Resistance Thermometers Model TR10-D, Miniature Design WIKA Data Sheet TE 60.04 Applications Machine building, plant and tank construction Power transmission

More information

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M The details make the difference MCB S 200/S 200 M A range designed to ensure efficiency and protection

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to

More information

VDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials

VDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials VDE Information General Information The voltage which can be applied to a terminal depends on the relevant regulations, the installation conditions and, of course, the dimensions and insulating materials

More information

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information. Wafer-carrier Mounting Photomicrosensors EE-SPY1/ CSM_EE-SPY1 DS_E_3_ Photomicrosensors for detecting wafer-carrier mounting. The mounting position is set with a pedestal. The contact surface with the

More information

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050 Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage

More information

Control and Distribution Boxes made of Stainless Steel Series 8150

Control and Distribution Boxes made of Stainless Steel Series 8150 www.stahl.de > Circumferential protection channel prevents water entry > Extended temperature range due to high-quality seal s > Optionally with hinges / cam locks or screw-on cover > Hinge versions with

More information

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404 /, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

5SV Residual Current Protective Devices

5SV Residual Current Protective Devices s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation.

14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation. 14 PHOENIX CONTACT PLUSCON circular is a circular connector for use in industrial automation. The range of design sizes available is varied, starting with the design sizes M5 to M8 and M1, for sensor/actuator

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461 D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex

More information

Universal MATE-N-LOK Connectors

Universal MATE-N-LOK Connectors Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification completely enclosed in housings Positive locking housings Insulation capability to.00

More information

Feed-through terminal block - SSK 110 KER-EX - 0502058

Feed-through terminal block - SSK 110 KER-EX - 0502058 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid

More information

Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated lightning impulse withstand voltage [kv] 75 125

Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated lightning impulse withstand voltage [kv] 75 125 Standards and Regulations IEC 62271-200 ; VDE 0671-200 ; BS EN 62271-200 Technical Data MC3-12 MC3-24 Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated

More information

Basics of Explosion Protection

Basics of Explosion Protection Basics of Explosion Protection INTRODUCTION Understanding Global Explosion Protection Class and Division System Class-Zone System CENELEC Zone System IEC A INTRODUCTION Basics of Explosion Protection Basics

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD IEC 61892-7 INTERNATIONAL STANDARD Edition 2.0 2007-11 Mobile and fixed offshore units Electrical installations Part 7: Hazardous areas INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE XA ICS 47.020.60

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

General Purpose Relays Accessories. Accessories Miniature Relay PT

General Purpose Relays Accessories. Accessories Miniature Relay PT Miniature Relay PT n Easy replacement of relays on a densely packed DIN rail n No reduction of protection class or creepage/clearance with plastic retainer n Plug-in indicator- and protection modules n

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

Operating Instructions

Operating Instructions Operating Instructions Control unit Ex p > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Designated Use...4 5 Technical Data...4 6 Transport, Storage

More information

Jumper bar BJM. Assembled jumper bar BJD. Assembled jumper bar

Jumper bar BJM. Assembled jumper bar BJD. Assembled jumper bar BJ Jumper bar Use the BJ jumper bar to connect consecutive and nonconsecutive terminal blocks with the same spacing. Two types of jumper bars are available : an assembled unit and a nonassembled unit.

More information

A product made in Australia. Insulated Conductor Rail ACTIV-8 PLUS

A product made in Australia. Insulated Conductor Rail ACTIV-8 PLUS A product made in Australia Insulated Conductor Rail ACTIV-8 PLUS ACTIV-8 PLUS The Industry Standard in Conductor Rails ACTIV-8 is the most widely used and stocked conductor rail in use in Australia. It

More information

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase

More information

Universal MATE-N-LOK Connector System

Universal MATE-N-LOK Connector System Universal MATE-N-LOK Connector System 2011 Tyco Electronics Corporation. All Rights Reserved. MATE-N-LOK, TE Connectivity, TE Connectivity (logo) and TE (logo) are trademarks. Other logos, products and/or

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

AMPSEAL* Automotive Plug Connector and Header Assembly

AMPSEAL* Automotive Plug Connector and Header Assembly AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2

More information