1.25Gbps GBIC Optical Transceiver, 20km Reach

Similar documents
155Mbps/1250Mbps SFP Bi-Directional Transceiver, 40km Reach 1310nm TX / 1550 nm RX

4.25Gbps SFP Optical Transceiver, 30km Reach

155Mbps DFB SFP Optical Transceiver, 120km Reach

2.488Gbps Compact Bi-Di SFP Transceiver, 20km Reach 1490nm TX / 1310 nm RX

DTSB35(53)12L-CD20 RoHS Compliant 1.25G 1310/1550nm(1550/1310nm) 20KM Transceiver

How To Connect A 10Gbps Sfp+ Bi-Directional Transceiver To A Single Mode Fiber With A Single Power Cell (Sfp+) To A Power Cell With A Power Source (Sf) (Sfl) (

SFP+ LR 10G Ethernet 10km SFP+ Transceiver 10GBASE-LR / 10BBASE-LW

LONGLINE 2km XFP Optical Transceiver

8.5Gb/s SFP+ Fibre Channel Optical Transceiver

10Gbps XFP Bi-Directional Transceiver, 10km Reach 1270/1330nm TX / 1330/1270 nm RX

Produto: 1.25Gbps SFP Bi-Directional Transceiver, 10km Reach (1310nm TX/1550nm RX) Modelo: V7-WDM-0210AD Documentação: Técnica/Datasheet

XFP Optical Receiver, 80km Reach

1250Mbps Gigabit Interface Converters (GBIC) Transceiver Module for Gigabit Ethernet

SFP-SX with DOM 1.25Gb/s Multi-Mode SFP Transceiver 1000BASE-SX Gb/s Fiber Channel

LONGLINE 10Gbps 10km SFP+ Optical Transceiver

DWDM SFP Series. Power budget* (note2) Laser

1000BASE-T and 10/100/1000BASE-T Copper SFP Transceiver

DWDM SFP Series. Power budget* (note2) Laser

10/100/1000BASE-T SFP Transceiver

10Gb/s SFP+ LRM 1310nm FP with PIN Receiver 220meters transmission distance

Product Specification. OC-12 LR-1/STM L-4.1 RoHS Compliant Pluggable SFP Transceiver. FTLF1422P1xTL

Product Specification. RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8512D3BCL

Dual Fiber SFP Series

SFP-GIG-SX 1000BASE-SX, Jusqu à 550 mètres de distance opérationnelle, Longueur d onde Laser 850nm, Fibre Multimode (MMF), SFP Optique Insérable

LONGLINE QSFP+ SR4. Features. Applications. Description. Page 1 of 13

LONGLINE 40km XFP Optical Transceiver

SFP+ DWDM Dual LC 10G SMF 40km Transceiver. Features. Applications APPLIED OPTOELECTRONICS, INC. A7ELXDxxEDMA0609

SFP-TX 1000BASE-T SFP Transceiver 10/100/1000M SFP Transceiver

X2 LR Optical Transponder, 10Km Reach

Product Specification 10Gb/s BIDI SFP+ Transceiver

10GBASE -LRM, 220m Reach GX LRMC

GPON OLT Optical Transceiver SFP Module RTXM Features

Fast Ethernet 100BASE-LX10 SFP Single Mode Transceivers with Digital Diagnostics

RoHS Compliant Copper Small Form Factor Pluggable (SFP) Transceiver for Gigabit Ethernet

GBIC CWDM 40km Part no:

EPON ONU Optical Transceiver SFF Module

10GBASE-LR XFP Optical Transceiver AXM752

10GBASE-SR XFP Optical Transceiver AXM751

10/100BASE-T Copper Transceiver Small Form Pluggable (SFP), 3.3V 100 Mbps Fast Ethernet. Features. Application

Intel Ethernet SFP+ Optics

Methode Electronics. DM-317-XXXX 40 Gbps QSFP+ Passive Cable RoHS COMPLIANT.

155Mbps ATM-Single Mode Transceiver

1000BASE-BX-OLT Transceiver

SO-QSFP28-LR4. QSFP, 100GBASE-LR, SM, DDM, 10km, LC SO-QSFP28-LR4 OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION DATASHEET 4.

Product Specification. 1000BASE-T RoHS Compliant Copper SFP Transceiver FCLF8520P2BTL / FCLF8521P2BTL / FCLF8522P2BTL

Part No. Data Rate Wavelength Interface Temp. DDMI

Product Specification ps/nm (~200km) DWDM XFP Optical Transceiver FTLX4213x3xxxx

PART NUMBER INPUT/OUTPUT SIGNAL DETECT VOLTAGE TEMPERATURE

Modultech MT-XDFx-xx192-08(04)CD 80 (40) km DWDM XFP module with built-in FEC wrapper Description

CISCO DWDM XENPAK. Main features of the Cisco DWDM XENPAK include:

Cisco SFP Optics for Gigabit Ethernet Applications

Methode Electronics. DM-338-GG-XXXX Up to 120 Gbps CXP Passive Cable Assembly.

RoHS compliant 1310 nm multi-mode Transceiver (2 km) 1x9, ST Duplex Plastic Connector, 3.3 V 155 Mbps ATM/ Fast Ethernet

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

SFP Copper Transceiver 10/100/1000Base-T

Enabling the Business Continuity & Change the way business communicates

WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor

SO-CFP-ER-DWDM. CFP, 103/112 Gbps, DWDM tunable, SM, DDM, 20km SO-CFP-ER4-DWDM OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION

CISCO 10GBASE X2 MODULES

US-SPI New generation of High performances Ultrasonic device

Serial 12.5 Gbaud, 10 km SMF Link with Clock and Data Recovery IC

Photolink- Fiber Optic Receiver PLR135/T1

Dispersion penalty test 1550 Serial

Golden test for dispersion penalty 1550 Serial

BF15U REV DESCRIPTION DATE APPROVED 2 Preliminary 1/7/2016 RAS/MF

Fiber Optics. Integrated Photo Detector Receiver for Plastic Fiber Plastic Connector Housing SFH551/1-1 SFH551/1-1V

Un-cooled Multimode Pump Laser Module for Telecom Applications

SFH Transmitter & Receiver

DS1621 Digital Thermometer and Thermostat

DS1621 Digital Thermometer and Thermostat

PMD Burst Mode Dynamic Performance Requirement

Signal Types and Terminations

US-Key New generation of High performances Ultrasonic device

Data Sheet. HFBR-0600Z Series SERCOS Fiber Optic Transmitters and Receivers

SP490/491 Full Duplex RS-485 Transceivers

Accurate Loss-of-Signal Detection in 10Gbps Optical Receivers using the MAX3991

Application Note 5016

Miniature Surface-Mount DAA for Audio or Data Transfer XE0402LCC BLOCK DIAGRAM

Fiber Optics and Liquid Level Sensors Line Guide

DVI Extender via 4 fiber channel LC Duplex Connector Extends DVI connection up to 500 meters

HDO700 P FIBRE OPTIC TRANSMITTER

Your Network. Our Connection. 10 Gigabit Ethernet

Cold-Junction-Compensated K-Thermocoupleto-Digital Converter (0 C to C)

Prisma IP 10 GbE VOD Line Card

155 Mb/s Fiber Optic Light to Logic Receivers for OC3/STM1

Duobinary Modulation For Optical Systems

Infrared Remote Control Receiver Module IRM-2638T

HARTING econ 3000 Introduction and features

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

SpectraTec II. Polarized Multi-Laser Source BLUE SKY RESEARCH WAVELENGTHS. The SpectraTec II

White Paper. Fiber Optics in Solar Energy Applications. By Alek Indra. Introduction. Solar Power Generation

Vertical Cavity Surface Emitting Laser OPV300, OPV310, OPV310Y, OPV314, OPV314Y

8 Gbps CMOS interface for parallel fiber-optic interconnects

DVI Extender via 4 fiber channel LC Duplex Connector Extends DVI connection up to 500 meters

DS1307ZN. 64 x 8 Serial Real-Time Clock

Rayson. Bluetooth Module

RLG842WVGPON ONU SPEC. RLG842WV GPON ONU Specifications

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

Transcription:

1.25Gbps GBIC Optical Transceiver, 20km Reach Features Dual data-rate of 1.25Gbps/1.0625Gbps operation 1310nm FP laser and PIN photodetector for 20km transmission Duplex SC optical interface Standard serial ID information compatible with SFF-8053 +3.3V/5Vsingle power supply RoHS Compliant Operating case temperature: 0 to +70 Applications Switch to Switch interface Switched backplane applications Router/Server interface Other optical transmission systems Description The GBIC transceiver is high performance, cost effective module supporting dual data-rate of 1.25Gbps/1.0625Gbps and from 20km transmission distance with SMF. The transceiver consists of two sections: The transmitter section incorporates a FP laser. And the receiver section consists of a PIN photodiode integrated with a trans-impedance preamplifier (TIA). All odules satisfy class I laser safety requirements. The optical output can be disabled by a TTL logic high-level input of Tx Disable. Tx Fault is provided to indicate degradation of the laser. Loss of signal (LOS) output is provided to indicate the loss of an input optical signal of receiver. The standard serial ID information Compatible with GBIC MSA describes the transceiver s capabilities, standard interfaces, manufacturer and other information. The host equipment can access this information via the two-wire serial CMOS EEPROM protocol. For further information, please refer to SFF-8053

Absolute Maximum Ratings Stress in excess of the maximum absolute ratings can cause permanent damage to the module. Table 1 - Absolute Maximum Ratings Parameter Symbol Min Typical Max Unit Maximum Supply Voltage Vcc 0.5-4.5 V Storage Temperature TS -40 - +85 Relative Humidity RH 0 - +85 % Recommended Operating Conditions Table2 - Recommended Operating Conditions Parameter Symbol Min Typical Max Unit Operating Case Temperature Standard TC 0 - +70 Power Supply Voltage VCC 3.1 5.5 V Power Supply Current Icc 300 ma Data Rate Gigabit Ethernet 1.25 Fibre Channel 1.0625 Gbps Optical and Electrical Characteristics (1310nm FP and PIN, 10~20km) Table3 - Optical and Electrical Characteristics (Operating case temperature TC=25, VCC=3.3V) Parameter Symbol Min. Typical Max. Unit Notes Transmitter Centre Wavelength λ C 1260 1310 1360 nm Spectral Width (RMS) σ 4 nm Average Output Power P0ut -9-3 dbm 1 Extinction Ratio ER 9 db Output Optical Eye IEEE 802.3z and ANSI Fibre Channel compatible 2 Data Input Swing Differential VIN 200 1600 mv 3 Input Differential Impedance ZIN 90 100 110 Ω TX Disable TX Fault Disable 2.0 Vcc V Enable 0 0.8 V Fault 2.0 Vcc+0.3 V Normal 0 0.8 V Receiver

Centre Wavelength λc 1260 1580 nm Receiver Sensitivity -22 dbm 4 Receiver Overload -3 dbm 4 Optical Path Penalty 1 db 5 LOS De-Assert LOSD -23 dbm LOS Assert LOSA -32 dbm LOS Hysteresis 1 4 db Data Output Swing Differential VOUT 550 1200 mv 6 Notes: 1. The optical power is launched into SMF. 2. Measured with a PRBS 2 7-1 test pattern @1250Mbps. 3. PECL input, internally AC coupled and terminated. 4. Measured with a PRBS 2 7-1 test pattern @1250Mbps, BER 1 10-12. 5. Measured with a PRBS 2 7-1 test pattern @1250Mbps, over 20km G.652 SMF, BER 1 10-12. 6. Internally AC coupled. EEPROM Section The SFF-8053 defines a 256-byte memory map in EEPROM describing the transceiver s capabilities, standard interfaces, manufacturer, and other information, which is accessible over a 2 wire serial interface at the 8-bit address 1010000X (A0h).

Pin Definitions Pin Diagram Pin Descriptions Pin Name Pin# Name/Function Signal Specification RGND 2,3,11,14 VDDR 15 Receiver signals Receiver Ground (may be connected sith TGND in GBIC) Receiver+3.3/5 volt (may be connected with VDDT in GBIC) Groud,to GBIC Power,to GBIC -RX_DAT 12 Receive Data,Differential PECL High speed serial.from GBIC +RX_DAT 13 Receive Data,Differential PECL High speed serial.from GBIC RX_LOS 1 TGND 8,9,17,20 VDDT 16 Receiver Loss of Signal,logic high,open collector compatible,4.7k to 10kΩpull up to VDDT on host Transmitter signals Transmitter Groud (may be connected with RGND internally) Transmitter +3.3/5 volt (may be connected with VDDR in GBIC) Low speed,from GBIC Ground,to GBIC Power,to GBIC -TX_DAT 18 Transmit Data,Differential PECL High speed serial,to GBIC +TX_DAT 19 Transmit Data,Differential PECL High speed serial,to GBIC TX_DISABLE 7 TX_FAULT 10 Transmitter Disable,logic high,open collector Compatible,4.7k to 10kΩ pull up to VDDT on GBIC Transmitter,Fault,logic high,open collector compatible,4.7k to 10kΩ pull up to VDDT on host Control signals MOD_DEF(0) 4 TTL low,output MOD_DEF(1) 5 SCL serial clock signal,input MOD_DEF(2) 6 SDA serial data signal,input/output Low speed,to GBIC Low speed,from GBIC Please reference SFF-8053,Annex D; Module definition 4

Block Diagram of Transceiver

Mechanical Dimensions References 1. Gigabit Interface Converter (GBIC) Transceiver Multi-Source Agreement (MSA). 2. Telcordia GR-253-CORE and ITU-T G.957 Specifications. Important Notice Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by LONGLINE before they become applicable to any particular order or contract. In accordance with the LONGLINE policy of continuous improvement specifications may change without notice. The publication of information in this data sheet does not imply freedom from patent or other protective rights of LONGLINE or others. Further details are available from any LONGLINE sales representative.