Wireless Solutions BROCHURE



Similar documents
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

A-317. Mobile Data Terminal. Android Platform Datasheet

Designed for the needs of automation, telecommunications, remote supervision, and monitoring

IntesisBox Modbus Server Fidelio IP

USB-500 Series Stand-Alone, Low-Cost Data Loggers

TK C -25 C 95% RH EMC TK701G TK701U TK704G TK704U TK704W. TK-Series Cellular Router

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

WISE-4000 Series. WISE IoT Wireless I/O Modules

IntesisBox Modbus Server SAMSUNG Air Conditioners

TK800-Series Industrial GPRS / UMTS / LTE Router

ENVIRONMENTAL MONITORING SYSTEM WITH WORLD-WIDE COVERAGE AND BIDIRECTIONAL COMMUNICATION VIA INMARSAT SATELLITE NETWORK

How To Run An Nport I5000A Device Server

MONITORING. m 3 /s. m/s F. g/m 3. Software. Data Input. M2M Transfer. Processing. Reports Graphs, Excel Alarms. Measurement Sensors Dry contacts

IntesisBox KNX Modbus TCP master

A&E Specifications RoadRunner Video Surveillance Systems for School Transportation Applications

Application/Connection Examples

Modbus Server SAMSUNG Air Conditioners

Application Note: Monitoring Branch Circuit Loads in Critical Facilities

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

MONITORING. Software. M2M Transfer. Data Input. Processing. Reports Graphs, Excel Alarms. Logging Analysis, Alarms Various products

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

Flexy-ble M2M router for remote access and data services. Industrial M2M Router.

A-307. Mobile Data Terminal. Android OS Platform Datasheet

MONITORING. m 3 /s. m/s F Pa. g/m 3. Software. Data Input. M2M Transfer. Processing. XML/HTTP SNMP, GPRS/SMS. Measurement Sensors Dry contacts

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

IntesisBox KNX - LON

MONITORING. Software. M2M Transfer. Data Input. Processing. Reports Graphs, Excel Alarms. Logging Analysis, Alarms Various products

Temperature Alert. LAN-based Temperature and Humidity Data Logger

M2M I/O Modules. To view all of Advantech s M2M I/O Modules, please visit

300Mbps Wireless N Gigabit Ceilling Mount Access Point

User manual Compact Web PLC WP240 series IEC-line

securityprobe 5E Standard

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

USB-500 Series Low-Cost Data Loggers and Accessories

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Your Best Connection. LTE/HSPA+/UMTS/CDMA/EDGE/GPRS Cellular Router Technology. for Cellular Solutions. Designed for M2M Applications

The All-in-One, Intelligent WLAN Controller

RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

SYNCHRONIZE DIGITAL CLOCK SYSTEM NETWORK DIGITAL CLOCK VER 1.0 DYNATEK

IntesisBox Modbus Server - Mitsubishi Electric G50

API Marine. BMS Presentation. Ballast Measurement Systems

June 21st, Change Ahead: IoT! Focus on. Environmental Monitoring Systems. Marco Zampolli South Europe Field Application Engineer

FM4100 USER MANUAL V1.4

Gigabit Multi-Homing VPN Security Router

Contents Chapter 1: Introduction... 3 Chapter 2: Ethernet (LAN)... 5 Chapter 3: ZigBee Wireless Connection Options... 7

Compatible with all of the Ravica range of Intelligent Sensors it provides a complete environmental, access control and security monitoring solution.

TX2123 RS485 TO ETHERNET ADAPTOR

Controller board and power supply for vivimat III systems

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL CAUTION CONNECTION DIAGRAM

IntesisBox KNX Modbus RTU master

Ha-VIS FTS 3000 Introduction and features

FT-1000/GPS-N. System of remote monitoring and control of physical

ACR120 Technical Specifications version 2.9 November 2005

USB-500/600 Series Low-Cost Data Loggers and Accessories

5GHz 300Mbps a/n Wireless Outdoor Access Point

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

How To Use A Ds340 (Dsp)

Vibration analysis and monitoring Compact. Powerful. Modern technology.

300Mbps Wireless N Gigabit Ceilling Mount Access Point

300Mbps Wireless N Ceiling Mount Access Point

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since automated production systems

Reducing operating costs of power generators with cloud-based remote management

PRImaGate Switch RACK 3U

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Communicate and view data from meters with one simple device

5GHz 300Mbps 13dBi Outdoor CPE

securityprobe5es -X20

Power & Environmental Monitoring

Thermal Centers Monitoring. Offer of converters TRM102, TRM202, TRM112, TRM212 and additional options.

GSM GATEWAY PRI / E1 RACK 3U

Deploy and Manage a Highly Scalable, Worry-Free WLAN

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Regards from the Team at Rheology Solutions.

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

Temperature & Humidity SMS Alert Controller

Complete SCADA solution for Remote Monitoring and Control

Unidirectional Transmitter/ Receiver Units Introduction

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Monitoring solar PV output

Indoor / Outdoor Antenna

Temperature & Humidity SMS Alert Controller

O C M III. Open Channel Flow Monitor

Process Alarm Solutions

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220

Accelerated Cellular Extender: Model 6200-FX Accelerated View Remote Management

Eaton epdu. Intelligent and flexible power distribution

KNX Panasonic Air Conditioners

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Remote Monitoring Unit SC8100. Monitoring Unit SC8100

AirMax g High Powered Outdoor CPE. PoE. Simple All-In-One Solution. Long Distance Radio. Clear. 10dBi

EM Family Datasheet. Overview. Easy to install at any scale

NEW. EVEN MORE data acquisition and test stand automation

Products Range Overview. Products Range Overview. The ZigBee Plug & Play wireless Network for Building and Industrial Applications

DOC# IMBU-PB-REMOTE-MONITORING-01-EN IMBU. Remote monitoring of industrial equipment

Expandable serial alarm system

HMS Industrial Networks

Transcription:

Wireless Solutions BROCHURE JUNHO 0

info@novusautomation.com www.novusautomation.com REV0 Temperature and RH Wireless Transmitter ISO 900 EMPRESA CERTIFICADA Introduction The is a wireless transmitter that when coupled with the provides an excellent solution for wireless monitoring of temperature and relative humidity variables. Together, they combine the ease of configuration and data acquisition operation of the RHT-RS8-LCD, which connects directly to a Modbus RTU bus, with the versatility of the wire-free installation of LogBox-RHT. Through the IEEE 80.. wireless interface, multiple s may talk to one or more AirGates, providing this way USB and RS8 communication paths to the main application. The uses high accurate sensors for measurements of the temperature, relative humidity and dew point. It also provides a LCD display for local viewing of the measurements while allowing reconfiguration of the transmitter parameters without having to run the configuration software on the computer. Features Operating limits: Sensor and probe: -0 to 80 C, 0 to00 % RH Electronic circuit: 0 to+ C, 0 to 9 % RH Power supply Internal battery: Lithium ½ AA de, V Battery autonomy: typically ano External supply (optional): 0 to Vdc, 70 ma max Wireless Protocol: IEEE 80.. Configurator software for Windows Accuracy: ± % RH from 0 to 80 % RH (at C) and ± C for temperature ABS housing with IP protection, for wall mounting (WM model). Nylon probe Probe extension (DM model): Stainless steel 0 or 0 mm of length Dimensions: 70 x 0 x mm Anatel certification Typical wireless range: Indoor: 00 meters In open field: 00 meters

info@novusautomation.com www.novusautomation.com Application Topology Star Topology Long Range Application Operating on this topology, up to Modbus slaves (wired or wireless) can be connected to the master through an. Modbus masters can be connected both to the RS8 and USB interfaces. Figure below shows a temperature and relative humidity monitoring system which is logged by a FieldLogger and is remotely supervised by the corporative network. It is possible to extend network ranges by using AirGateModbus as a repeater. Acting as a repeater, AirGateModbus allows the connection of wired devices through its RS8 interface. Figure below shows a two-level system using a couple of, one acting as a wireless repeater and the other with two Modbus masters multiplexed connected to the physical interfaces USB and RS8. Room Supervision and logging through the Modbus network Room Room Room Wireless repeater Master multiplexer Room Local logging by FieldLogger Supervision through the corporative network Room Room Room Configuration Software Configurador Diagnostics software is the configuration tool. By using it connected to the USB interface, it is possible to configure all transmitter's communication parameters, besides offering advanced and important diagnostics information for installation and maintenance of the wireless communication system. allows access to real-time information during system operation. Some of the parameters that can be checked are: Battery level Wireless reception signal intensity Type of the wireless connection with other devices Temperature, relative humidity and dew point Interconnection visualization Visualization of the wireless devices interconnection makes network diagnostics, installation and expansion very easy to make. shows stablished connections between several equipments of the network, simplifying the network topology analysis and allowing optimization of the system installation. Dispositivos DigiRail DigiGate-Profibus RHT-8-LCD Identificação do Dispositivo Título Modelo Long MAC 00::A:00:0:B:00:7 Número de Série 878 Short MAC 00:08 Versão do Firmware V.0 S/N 878 V.0 AirGate-GPRS Outros Dispositivos Configuração do Dispositivo Wireless RHT Diagnóstico Nível da Bateria Conexão Nível de Sinal Rx,7 V Wireless Valores Instantâneos Valor Ótimo Offset Temperatura:, C 0,0 Umidade Relativa 0, % 0,0 % Ponto de Orvalho:, C Opções de Pesquisa Endereço Inicial Última Atualização: Endereço Final 0 Próxima Atualização: 00:00: //0 ::0 Pesquisar Aplicar Cancelar Configurador Dispositivos DigiRail DigiGate-Profibus RHT-8-LCD Identificação do Dispositivo Título USB-Master S/N V.7 USB-Master Modelo Número de Série Versão do Firmware.7 Long MAC 7:E:F::::7:E Short MAC 00:00 Versão do MAC S/N V.7 Configuração do Dispositivo Básica Diagnóstico Avançada S/N 007 V.7 Endereço Inicial: Pesquisar Endereço Final: 0 S/N 878 V.0 Topologia Mesa S/N 8788 V.0 Mesa S/N 878 V.0 AirGate-GPRS Outros Dispositivos Tipo: Modbus: Modbus pai: LQI Rx LQI Tx Opções de Pesquisa Endereço Inicial Endereço Final 0 Pesquisar Aplicar Cancelar

Router AirGate-G NOVUS Cloud The AirGate-G is a cellular router for Internet of Things (IoT) applications and provides remote access to local networks. It acts as a Modbus RTU master and reads up to registers of Modbus remote channels. All data generated can be published on NOVUS Cloud platform, which allows access anytime and anywhere, besides providing efficient and reliable storage. Features Dual SIM card redundancy for continuous cellular connection, supports G/G Modbus Gateway provides routing between Modbus RTU/ ASCII and Modbus TCP networks Up to alarms signaling through SMS and e-mail Digital Input and output with pulse counting Auto reboot via SMS, through identified phone call and by watchdog timer Two fully configurable RS and RS8 serial interface Dual port ethernet interface 0/00 Mbps (for LANs or LAN + WAN) NOVUS Cloud service connectivity for data storage and browsing USB.0 host port allows local firmware update and configuration Temporary local data recording ensure data integrity even during long connection lost events. Storage on USB flash drive, local memory or MicroSD card NOVUSLink: MM centralized management platform for remote monitoring, configuration and firmware updates Flexibility both on monitoring and set up methods: Web, CLI, SNMP v/v/v, SMS, NOVUSLink Firmware update via Web, CLI, USB, SMS, NOVUSLink Opening VPN tunnel possibility for full safety during remote access Metal enclosure with DIN mm mounting kit ANATEL, CE and FCC certified Dimensions: x x 0 mm Operating temperature: -0 to 8 C / to 9% RH Power supply: 9 to 0 Vcc OPTIONAL: GPS for real time location and tracking Articulating antenna NOVUS Cloud Application Topology XL Family All-In-One Controller Ethernet Temperature and RH Wirelles Transmitter AirGate-G Router Gateway N00 Universal Controller NOVUS Automation Phone: + -00 E-mail: info@novusautomation.com www.novusautomation.com FieldLogger Acquisition and Data Recording

Contactos/Contacts: Comercial/Commercial: Fernando Mena Costa e-mail: fcosta@bhb,pt Tel: (+) 8 00 Fax: (+) 8 09 Assistência/Service: Patricia Costa e-mail: ppcosta@bhb.pt Tel: (+) 8 00