Application Note No. 12



Similar documents
Recommended KEPServerEX Settings for groov

DCOM settings for computer-to-computer communication between OPC servers and OPC clients

POS Connector Installation and Setup Guide

PCLinq2 Hi-Speed USB Bridge-Network Cable. Quick Network Setup Guide

Configuring Network Load Balancing with Cerberus FTP Server

LPR for Windows 95/98/Me/2000/XP TCP/IP Printing User s Guide. Rev. 03 (November, 2001)

1 Installation. Note: In Windows operating systems, you must be logged in with administrator rights to install the printer driver.

BioWin Network Installation

DP-313 Wireless Print Server

Microsoft Outlook 2000 Configuration Creation of a SPAM Filter

Windows 98 and Windows Me

ENABLE LOGON/LOGOFF AUDITING

1. Installing The Monitoring Software

Printer Driver Installation Guide

SOP085 - HELLER OVEN SOFTWARE INSTALLATION PROCEDURE. For version 6.2.x.x

A browser must be open and connected through Jeffco s network How to set up network printing over WI-FI

Configuration Guide. Remote Backups How-To Guide. Overview

How to recover IE Client

SmartSync Monitor Help

Also you need the C-MOR ISO file. This file you will find following this link:

Quick Installation Guide for BrainTrading System 7.0

PRINT CONFIGURATION. 1. Printer Configuration

Print Audit 6 - SQL Server 2005 Express Edition

SecuraLive ULTIMATE SECURITY

Magaya Software Installation Guide

Outlook Profile Setup Guide Exchange 2010 Quick Start and Detailed Instructions

64-Bit Compatibility with Micromeritics Applications

LPR for Windows 95 TCP/IP Printing User s Guide

Backup Server DOC-OEMSPP-S/6-BUS-EN

S7 OPC Server Tutorial

e-dpp May 2013 Quick Installation Guide Microsoft Windows 2003 Server, XP, Vista, 7 Access Database

Installing a printer in Windows 95.

Internet Guide. Prepared for 55 John Street

Connecting to SQL server

Network Server for Windows. Overview of the Sequencher Network Page 2. Installing Sequencher Server for the First Time Page 3

Configure VPN between ProSafe VPN Client Software and FVG318

Central Management System

Deploying Windows Streaming Media Servers NLB Cluster and metasan

Setting up a networked printer on a local PC

Start Here. Installation Guide. Rosetta Stone Standalone License. This Guide Will Show You How To: Install the Student Management System...

Guide to Setting up Internet Connection Sharing for Windows

Kepware Technologies OPC Quick Client Connectivity Guide

Installing the Gerber P2C Plotter USB Driver

Option nv, Gaston Geenslaan 14, B-3001 Leuven Tel Fax Page 1 of 14

How to setup a VPN on Windows XP in Safari.

Client Program Installation Guide

MF Driver Installation Guide

Client for Macintosh

QUANTIFY INSTALLATION GUIDE

Enabling Internet Connection Sharing on Windows Enabling ICS On Windows XP As The Host 4 Enabling ICS On Windows XP As The Client 11

5.6.3 Lab: Registry Backup and Recovery in Windows XP

Tournament Pairing Program Installation Instructions for Windows 7

Introduction. There are several bits of information that must be moved:

VPN SOFTWARE - WINDOWS XP & WINDOWS 64-BIT INSTALLATION AND CONFIGURATION INSTRUCTIONS

Interfacing PC ChargePayment Server with Focus

User Manual. 3CX VOIP client / Soft phone Version 6.0

You may refer the Quick Installation Guide in the package box for more information.

Brady IP Printer Installation Instructions

This document details the following four steps in setting up a Web Server (aka Internet Information Services -IIS) on Windows XP:

Upgrading from Call Center Reporting to Reporting for Call Center

Diamond II v2.3 Service Pack 4 Installation Manual

Windows Server 2003 x64 with Symantec AntiVirus 10 Corporate Edition

Method 1: SecuRemote Client VPN Software

Use this guide if you are no longer able to scan to Sharpdesk. Begin with section 1 (easiest) and complete all sections only if necessary.

StarWind iscsi SAN: Configuring HA File Server for SMB NAS February 2012

StarWind iscsi SAN Configuring HA File Server for SMB NAS

Colorfly Tablet Upgrade Guide

etoken Enterprise For: SSL SSL with etoken

How to integrate Verax NMS & APM with Verax Service Desk

Chapter 6 Basic Virtual Private Networking

Juniper NetScreen IPSec Dial Client. Installation Guide for Windows 2000 Windows XP Windows Vista

ACR Triad Site Server Click Once Software System

TRENDnet. <a trendnet.com"> Quick Installation Guide. Product Warranty Registration

Installation Notes for Outpost Network Security (ONS) version 3.2

Kepware Technologies KEPServerEX Client Connectivity Guide for GE's Proficy ifix

Remote Backup Software User Manual V 2.0

Setting up Hyper-V for 2X VirtualDesktopServer Manual

Creating a Client-To-Site VPN. BT Cloud Compute. The power to build your own cloud solutions to serve your specific business needs.

Network Printing In Windows 95/98/ME

Defender EAP Agent Installation and Configuration Guide

EPSON Scan Server & EPSON TWAIN Pro Network

Setting up a Virtual Private Network (VPN) connection Windows 8

Backing Up and Restoring Microsoft Exchange Server Cloud Attached Storage. August 2012 Version 3.2

Printing Options. Netgear FR114P Print Server Installation for Windows XP

Lesson 3: Installing Tally.ERP 9 Gold

CREATING AN IKE IPSEC TUNNEL BETWEEN AN INTERNET SECURITY ROUTER AND A WINDOWS 2000/XP PC

Printer Sharing of the PT-9500pc in a Windows Environment

Installing LearningBay Enterprise Part 2

Installing Windows Server Update Services (WSUS) on Windows Server 2012 R2 Essentials

Verbatim Secure Data USB Drive. User Guide. User Guide Version 2.0 All rights reserved

Setting up your laptop to print to the student lounge printer

Preparing the Computers for TCP/IP Networking

Windows Offline Files

DSX-HSCS Hot Swap Comm Server

Installing the Driver of your Plotter- / Engraver

For paid computer support call

Transcription:

Application Note No. 12 Product: Keywords: Problem: Softing OPC Easy Connect OPC Server, Redundancy How to configure redundant server connections Solution: Initial situation: An OPC client application is connected to multiple redundant OPC servers which simultaneously communicate with a physical device (eg PLC). Both OPC servers determine the same data from the PLC. In case of a failure in one of the server connections the OPC client application should automatically switch to the other redundant server connection. This automatic switching is not implemented in the Softing products. The implementation of the redundancy mechanism must be made in the client of the customer. However, if the used OPC client application implements a redundancy mechanism, then it is possible to configure redundant server connections via Softing s. The is part of Softing s OPC Easy Connect Suite; a collection of OPC middleware products that simplify OPC communications. Designed as a DCOM bypass, the allows reliable, high-performance communication between OPC components on networked computers. The installations on the client side and the server side communicate via a TCP/IP connection. In this way, the data that is exchanged between client and server applications are tunnelled over TCP/IP; bypassing DCOM completely. 1

Configuration of redundant server connections: This document discusses how to implement the configuration depict in the picture below. For our purpose, the is installed on all computers. Two instances of the will be used on the client side on PC1. The name of the first instance is left empty and cannot be changed. The second instance will get a unique name (OCT-2). 1.) First we configure a Server-side Tunnel on PC2. Go to PC2 and double click on the system tray icon of the OPC Easy Connect: In the Tray application select the instance and press the Configure -Button. 2

Clicking the Configure button opens the Project Wizard. Please enter the following settings in each step of the Project Wizard (you find the title of the dialog in the dialog caption): Dialog Title Product Tunnel Server System Connection Type DA Provide Items Server Connection Test Settings Select and press Next> Select Server side and press Next> IP Port 56765 is suggested. IP Port 8090 is suggested. Press the button Add Server Connection Select DA Server Select from the local Data Access server list your first (redundant) OPC Server Live the default settings Press Connection Test to check, if the selected local OPC Server can be started. Then press Finish Press Finish The Wizard will display the following message: The project contents will be deleted. Do you want to create a new project? Click on Yes and exit the OPC Easy Connect configurator. Double click on the system tray icon of the OPC Easy Connect, select the instance, and press the Restart button to activate the Tunnel Server instance with your settings on PC2. 3

2.) Repeat the previous steps on PC3 to configure the second redundant Server-side Tunnel. The IP Port will be automatically set by the Project Wizard. Please don t change the default setting. Since the redundant OPC servers are installed on different computers, the OPC Tunnel IP port can be set the same on both PCs to "56765". Note: In case the two redundant OPC servers are installed on the same computer you also need to configure two instances and each IP port must be set differently! 3.) Next, the two Client-side Tunnel instances need to be configured on PC1. Double-click the icon in the taskbar of the OPC Easy Connects on PC1: Select the instance and press the Configure -Button. Please enter the following settings in each step of the Project Wizard: Dialog Title Product System Connection Type: DA/AE Server Provide Items Server Connection Test Settings Select and press Next> Select Client side and press Next> IP Port 8090 is suggested. Take this and press Next> Press the button Add Server Connection Select Tunnel DA Server and press Next> Enter the computer name or the IP-Address from PC2 and take the suggested IP Port 56765. Press Next> Live the defaults Press Connection Test to check, if your Tunnel Client can connect the OPC Server on PC2. Then press Finish 4

Press Finish Save your settings and exit the OPC Easy Connect configurator. Next create the second Tunnel Client instance in the OPC Easy Connect Tray. Press the Add Button, enter the name of the second instance (OCT-2) and click on the OK Button. Select this newly created instance and press the Configure Button. Please enter the following settings in each step of the Project Wizard: Dialog Title Product System Connection Type: DA/AE Server Provide Items Server Connection Test Settings Select and press Next> Select Client side and press Next> IP Port 8091 is suggested. Take this and press Next> Press the button Add Server Connection Select Tunnel DA Server and press Next> Enter the computer name or the IP-Address from PC3 and take the suggested IP Port 56765. Press Next> Live the defaults Press Connection Test to check, if your Tunnel Client can connect the OPC Server on PC3. Then press Finish Press Finish Save your changes and exit the Configurator. In the Tray application select the first instance and press the Restart button. Then select the second instance and start (or restart) it as well. 4.) The Softing OPC Toolbox Demo Client contains no true redundancy mechanism, but it is a good tool for testing the two configurations. However, you cannot test the automatic transfer from one server to another server with the Softing OPC Toolbox Demo Client. This has to be tested with the OPC Client that supports the redundancy mechanism. 5

Note: If the name spaces of the two redundant OPC servers differ (e.g. different manufacturer), a user can modify the name space of both OPC servers via the filter functionality of the. The filter allows a user to configure (rename) the visible OPC item names (attribute "ItemID") as needed using the filter mechanism, but the attribute value of "ServerItemID" may not be changed! Licensing of the : You need the basic Easy Connect Suite license (OPC-EC-BCL) for all three computers. In addition, you will need one server extension license (OPC-EC-SRV-10) for PC1, since two simultaneous server connections are used on this computer. Note: The basic license of Softing s Easy Connect Suite only supports one server connection at a time. 6