USER GUIDE SERIES 4250 AUDIO ALARM CONFIRMATION SYSTEM CONTROL UNIT



Similar documents
MONITOR ISM / AFx Multi-Tenant Security System User Guide V1.3

CONTENTS 4. HOW TO UNSET THE PANEL...7

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

astec Integrated Alarm System USER GUIDE

NetworX NX-6V2. LED Keypad User Manual

Accenta/Optima. User Guide. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number: Honeywell Security

SECURITY SYSTEM NOTES

How To Set A Timer On A Gg System

SECURITY SYSTEM NOTES

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES

Intruder alarm system Operating Instructions

User Guide Veritas 8/Veritas 8Compact/Veritas R8 INS036-5

SECURITY SYSTEM NOTES. EMERGENCY ACTIVATION KEYS (check if enabled) PROGRAMMED FUNCTIONS

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

XR1. Intruder alarm system Operating Instructions. Unset system indications. Set System indication

Using your LED Plus keypad

Users Guide to Keypad Functions

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO B ISSUED AUG 2002 VERSION 1.18

FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM

D1260/D1260B. Keypad. National Security Systems Inc (800) Owner's Manual

HILLS Series LED Code Pad User Manual

HARDWIRED CONTROL PANELS

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

SECURITY SYSTEM NOTES AREA LISTINGS SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS

NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version)

TS590. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT 0 ESC

CS450. User Manual

HILLS Series LED Code Pad User Manual

SECURITY SYSTEM NOTES SPECIAL CODES. Security System Configuration

616, 626, 636 & 646 Keypads

SECURITY SYSTEM NOTES. Security System Configuration

EURO User Manual. Castle Care-Tech 2012 (RINS1531) Issue 2. Page 1

IDS X-Series User Manual D Issued July 2012

User s Guide. Security Systems D220

NESS D Zone Control Panel and Dialler OWNER S MANUAL

Security System. User's Guide. Keypad

SECURIT 800L+ CONTROL PANEL

SECURITY SYSTEM NOTES SPECIAL CODES AUXILIARY ARM / DISARM CODES ENTRY / EXIT DELAY TIMES ZONE DESCRIPTIONS

VISTA-128FBP VISTA-250FBP Commercial Fire and Burglary Partitioned Security Systems with Scheduling

Microprocessor Intruder Alarm System User Guide

User s Information Guide R1A

National Security Systems Inc (800) Security System User's Guide

Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function

3 6HFXULW\6\VWHP 8VHU*XLGH K4333 9/99 AWAY BYPASS STAY ALARM FIRE ARMED OFF AWAY STAY READY MAX TEST BYPASS INSTANT CODE CHIME

9452/9453 Installation and User Guide

VISTA-50P VISTA-50PUL

Lynx Plus Series Security System

FA701 Series. User s Guide. K6249-2V2 5/09 Rev. A

500r+ Installation and User Guide

Diamond + User Manual. Wireless Alarm System. Default codes: User code: 1234 Master Manager Code: 2222

8VHU V*XLGH 6HFXULW\6\VWHPV (QWUHSUHQHXU(1 6HFXULW\0DQDJHU(1. Meets ADT Security Services Triple Standards Requirements:

SCORPION Z16040C Alarm Controller User Instructions

Security System User Guide

VISTA-100. Commercial Fire and Burglary 8VHU*XLGH. Partitioned Security System. N Rev B 4/99 FIRE FIRE PULL

PowerWave-8. Users Operating and Programming Guide Version zone Control panel Communicator

LYNX Touch Security System

Solution-16 Operators Manual ISSUE 1.60

USER INSTRUCTIONS CONTENTS

D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST

MATRIX 6/816. Control Panel with Remote Keypads Software Version 1.34 USER MANUAL RINS545-7

HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide

GC2 Panel User Guide

6HFXULW\6\VWHPV 8VHU V*XLGH K5309-1V1 8/01

P/N Rev D

User's Manual 5120XM N8031 6/96

The Challenger Version 8 User Guide

LYNX Touch Security System

Elite 8D/Lite Version 8 Zone Controller. Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

tattletale User Guide Consumer unit version P a g e

User.QXD 09/05/00 14:47 Page 1 Gardtec /582 User Instructions

Destiny Destiny Owners Manual

S I E R R A PRODUCT INFORMATION GUIDE FOR HOME SECURITY. SIERRA Page 1

Quick Reference Guide

LYNX Touch L7000 Series Security System

LYNX Touch L5200 Series Security System

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual

Quick Installation Guide LCD GSM ALARM SYSTEM LH

LYNX Touch L5210 Series Security System

USER GUIDE HARDWIRED CONTROL UNIT

User Manual Wireless Alarm System RINS PIEZO WARNING The wireless system contains a loud siren, please be aware of this after an activation

Using Your. Security System With Icon Keypad S5020, S5021, S5022

INSTRUCTION MANUAL PC5OO WITH PC5OORK KEYPAD

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

User Manual. Wireless Alarm System. PIEZO WARNING: This wireless alarm system contains a 100dBA siren, please be aware of this after activation.

642 LCD Keypad User Manual

SPECIAL CONTROL BUTTON FUNCTIONS

Master User Guide Premier Elite 24/48/88/168/640

SECURITY SYSTEM MANUAL

NetworX Series. NX-148E LCD Keypad. User Manual

GE Concord 4 Quick User Guide

LCD and 16-Zone LED Keypads. User s Manual

ADEMCO LYNXR-EN Security System

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

Wireless Security System

CA60 Plus Software Version 3.1 User Manual May 2000

Euro-MERiDIAN. NEplus. Intruder Alarm System. Operator s Instructions

CS250 LCD Keypad User Manual

Solution 880 Operators Manual ISSUE 1.10

ADEMCO VISTA-48A ADEMCO VISTA-48E Security Systems

User s Guide. Security Systems

Transcription:

USER GUIDE SERIES 4250 AUDIO ALARM CONFIRMATION SYSTEM CONTROL UNIT

CONTENTS Page INTRODUCTION... 2 Security conditions... 3 Full Set (Fully armed)... 3 Part Set (Partially armed)... 3 Unset (Disarmed)... 3 GLOSSARY OF TERMS... 4 USER CONTROL... 6 Keypad LED status indicator... 7 SETTING THE SYSTEM (TURNING THE SYSTEM ON) Full Set (Full Arming)... 8 Problems when selecting FULL SET Zone fault conditions... 9 Incorrect code entry... 10 Deviation from correct Exit/Entry procedure... 11 Failure to complete exit procedure... 12 Part Set (Partially armed) Delay selection... 13 Instant selection... 13 UNSETTING THE SYSTEM (Turning the system off) Unsetting from a FULL SET condition... 15 Unsetting from a FULL SET condition after Alarm activation... 16 Page Unsetting from a PART SET condition... 17 Problems when unsetting the system Deviation from Entry route... 19 Zones not restored during entry time... 19 PROCEDURE FOR RESETTING THE SYSTEM AFTER AN ALARM INDICATION... 20 EMERGENCY DURESS... 21 VIEWING ALARM HISTORY LOG... 22 SYSTEM FAULTS Mains power failure... 23 Backup battery failure... 24 Telephone line faults... 25 Tamper faults... 27 Wiring fault conditions... 28 TEST SIGNAL... 29 CHIME MODE (OPTIONAL FEATURE)... 31 ADVANCE SYSTEM FEATURES Adding additional access codes... 33 Removing additional access codes... 33 Multiple partition arming/disarming... 34 Omitting zones to allow system setting... 35 Advanced alarm history... 36 1

INTRODUCTION The 4250 Alarm System is one of the latest advanced security systems available and is designed to be fully in compliance with the latest industry standards. It provides 24 hour supervised remote monitoring with audio confirmation of security occurrences. The system may be set up to protect either a complete building or selected parts of it. On detection of a possible security breach an alarm signal is sent to the Alarm Receiving Centre, where an operator can monitor and listen to the alarm activity at the premises and take the appropriate action. This may include alerting the local police and/or a designated keyholder in accordance with ACPO procedures. Depending on the application of the system ie. domestic, commercial and/or nature of the risk, one of three security modes, SECURE, AUTOMATIC or AUTO-NO DIAL can be pre-defined by the Alarm Company when the system is set up by the Alarm Company Engineer. If the applications require changes after the equipment is installed, then the customer must contact the Alarm Company. ADT Modern Service Tel No.............. Alarm Receiving Centre Tel No.............. 2

INTRODUCTION SECURITY CONDITIONS Three security conditions are available to the user and can be selected using the keypad. They are as follows: FULL SET (Fully armed): Selected to turn the system on when protection of the complete premises is required, PART SET (Partially armed): Selected to turn the system on when protection is limited to pre-defined areas of the premises e.g. upper floor rooms protected and lower floor rooms unprotected. UNSET (Disarmed): Selected to turn the system off. However, 24 hour zone sensors ie. PA buttons and emergency duress buttons are still monitored and if activated will alert the Alarm Receiving Centre Operator. 3

GLOSSARY OF TERMS Duress code: A code entered at the keypad that will unset the system, and will also transmit the duress condition to alert the Alarm Receiving Centre. Part Set: Security condition selected by the user at the keypad. Chosen to allow pre-defined areas of the premises to be protected when other areas are occupied. User code: A x digit user code which is used to operate the system eg. Setting Unsetting. Master code: A x digit user code allocated to a system user for entering advanced feature options. Entry time: Exit time: LCD: LED: A pre-set time delay on entry to allow the user to reach the keypad and unset the system. A pre-set time delay to allow the user to leave the premises after initially setting the system at the keypad. Liquid Crystal Display. Light Emitting Diode status indicator on the keypad. Full Set: Unset: Zone: Security condition selected by the user at the keypad. Selected to give full protection for the complete premises. Security condition selected by the user at the keypad. Selected to switch the system off. A zone is an area eg. room, corridor, that is monitored by a device such as a movement detector, door contact etc. 24 hr Zone: An alarm circuit which has been programmed to give 24 hour continuous protection whether the system is set (on) or unset (off). Personal Attack (PA): Emergency switch or push button used to trigger the alarm system which results in the Alarm Receiving Centre Operator being 4

GLOSSARY OF TERMS Final Exit/ EntryDoor: Exit Terminator: alerted. The last door closed by the user on exit and the first door opened on entry. A switch or push button located on the outside of the premises adjacent to the Final door. Used to finally set the system. 5

USER CONTROL The user controls the system by means of a keypad. Keypad LCD Display Numeric Keys LED Status Indicator enter Function Selection Keys Note: The LCD will display messages, prompt entries and indicate the functions of the selection keys. 6

USER CONTROL Keypad LED status indicator The LED on the keypad changes colour depending on the status of the alarm system. The colours are designated as follows: RED: System is in FULL SET mode (Armed). YELLOW: System is in PART SET mode (Partially armed). GREEN: System is in UNSET mode (Switched off). FLASHING RED: An alarm has occurred whilst system was in FULL SET mode. FLASHING GREEN: Mains power supply has failed. NOTE: Battery back up is provided to power the system during mains failure. However, if the length of time the mains power is disrupted gives cause for concern contact the Alarm Company Service Department using the telephone number shown on page 2. 7

SETTING THE SYSTEM (TURNING THE SYSTEM ON) FULL SET (Full Arming) The FULL SET selection procedure is as follows: 1) Close all doors and windows to secure the premises. 2) Prior to setting the system the keypad LED will be a steady green indicator and the Keypad Keypad LCD Display will show. 4) The Keypad LCD Display will change and you will be prompted to enter your x digit user code and press the enter button. 5) Key in the x digit user code and press enter. 6) After a short delay the code will be verified, the keypad and Exit/Entry buzzer (if fitted) will start to bleep. The keypad will begin to countdown a predetermined time in seconds to allow exit from the premises. 7) Leave the premises immediately via the designated Exit/ Entry route, close and lock the final door and operate the Final Exit Terminator switch. If the Exit Terminator switch is not operated the system will automatically set after the predetermined exit time. Part-Set Full-Set 3) Press FULL SET key 8. The keypad then beeps twice and the buzzer stops to confirm that the system is set. 8

SETTING THE SYSTEM (TURNING THE SYSTEM ON) PROBLEMS WHEN SELECTING FULL SET The keypad display text will indicate the reason which prevents the user selecting FULL SET. Zone fault conditions If alarm devices, other than the final door or Exit/Entry alarm devices are open or activated then this will prevent the setting procedure being started. Before setting the system all monitored zones, i.e. doors and windows must be secured. If a fault exists when attempting to set the system the keypad display will show a message indicating where the fault is located. For example, the following display, indicates the system remains UNSET due to a fault in zone 05. Note: A zone is an area such as a room or corridor that is monitored by a device such as a movement detector, door contacts etc. Omit key Next key If more than one fault exists by pressing the Next key other faults will be displayed in sequence. When the fault(s) indicated have been cleared, carry out the setting procedure for FULL SET. If the fault(s) cannot be immediately cleared and the user needs to set the system, the faulty zone(s) can be omitted from the system by the user with a master code (page 35). This facility is subject to insurance company agreement. 9

SETTING THE SYSTEM (TURNING THE SYSTEM ON) PROBLEMS WHEN SELECTING FULL SET Incorrect code entry If the incorrect code is entered during selection procedure the keypad LCD Display will show. Press the RETRY key and enter the correct code. After 3 attempts to enter your code the system will refuse further setting attempts for two minutes and this condition is reported to the Alarm Receiving Centre. After the two minutes have elasped a further 3 attempts may be made. Retry key 10

SETTING THE SYSTEM (TURNING THE SYSTEM ON) PROBLEMS WHEN SELECTING FULL SET Deviation from the Correct Exit Procedure Deviating from the designated Exit route when the countdown period has started will cause the keypad exit bleep to change to a continuous tone. Returning to the correct route, i.e. closing any doors on the wrong route will cause the keypad bleeper tone to change to the normal intermittent bleep and you will be able to exit normally. If any zones having been entered by deviating from the exit route are not restored, e.g. doors not closed, within the set exit time the keypad display will show: The FAILED TO EXIT condition will be reported to the Alarm Receiving Centre and the audible tone will continue to sound until the x digit user code is entered. Pressing the * key will display the fault status condition. Eliminate the fault and repeat the FULL SET procedure. 11

SETTING THE SYSTEM (TURNING THE SYSTEM ON) PROBLEMS WHEN SELECTING FULL SET Failure to complete exit procedure If during the FULL SET procedure the user fails to exit the premises with in the set exit time the setting fault condition will be indicated on the keypad LCD as shown: The FAIL TO EXIT condition is reported to the Alarm Receiving Centre and the keypad audible tone will continue to sound. To reset the system, key in your x digit user code and press enter. 12

SETTING THE SYSTEM (TURNING THE SYSTEM ON) PART SET (Partially armed) The PART SET condition allows the alarm system to be armed (set) in certain zones of the protected premises while the remainder of the premises are occupied. Two PART SET selections are available as follows: Delay selection: This feature is selected when access to the non-alarmed (occupied) area is via a protected part of the premises. When the PART SET delay selection is set at the keypad there is a time delay to allow the user to leave the protected area. On entering the protected area by the normal entry route there is a similar time delay to allow the user to key in the x digit user code to UNSET (switch off) the system. During both time delays the keypad will bleep. An example of using this selection is a house with the downstairs protected and the upstairs occupied but the occupants require access to the keypad to PART SET or UNSET the system. Instant selection: This feature is selected when access to the occupied area is not via a protected part of the premises. In this instance the keypad is located outside the protected area eg. a keypad is upstairs enabling the downstairs to be PART SET/UNSET with no time delay. Any intrusion downstairs will result in an alarm signal being reported to the Alarm Receiving Centre. 13

SETTING THE SYSTEM (TURNING THE SYSTEM ON) PART SET (Partially armed) 3) Press the Part Set key and the display will show. To PART SET the system do the following: 1) Secure the pre-defined area to be protected. 2) The keypad LCD will display. Delay key Instant key 4) Select Delay if time delay is required to exit the protected area or Instant if no time delay is required. Part Set key Full Set key 5) When Delay or Instant is selected, the display will request the x digit user code to be entered. 14 6) Key in the x digit user code and press enter. 7) If Delay is selected leave the protected area within the preset exit time.

UNSETTING THE SYSTEM (TURNING THE SYSTEM OFF) UNSETTING FROM A FULL-SET CONDITION To unset (disarm) the FULL-SET condition carry out the following: 1) Enter the premises via the designated Exit/Entry door or route. 3) Key in the x digit user code at the keypad and press enter. After a short delay the code will be verified the keypad bleeper will cease whilst the keypad display will show: 2) The keypad bleeper and Entry route buzzer, if fitted, will sound intermittently as a reminder to disarm the system before the entry time expires. The display will show: 15

UNSETTING THE SYSTEM (TURNING THE SYSTEM OFF) UNSETTING FROM A FULL SET CONDITION AFTER ALARM ACTIVATION Perform the unsetting procedure on page 15. During the unsetting procedure the keypad status LED indicator will be flashing red to indicate an alarm has occurred. The keypad display will alternate between: and By pressing the * key on the keypad the display will show the alarm history log indicating where the intrusion has taken place. The user must contact the Alarm Company or Alarm Receiving Centre to investigate the reason for activation and to obtain a System RESET before it can be FULL SET again. 16

UNSETTING THE SYSTEM (TURNING THE SYSTEM OFF) UNSETTING FROM A PART SET CONDITION To UNSET the system from PART SET with Delay carry out the following: 3) Key in the x digit user code and press enter. The display will show: 1) Enter the protected area by the designated route, the keypad bleeper will sound and the keypad display will show: Unset key 2) Press the Unset key. 17

UNSETTING THE SYSTEM (TURNING THE SYSTEM OFF) To UNSET the system from PART SET with Instant carry out the following: 4) The keypad display will show: 1) The keypad display will show: 2) Press the Unset key. 3) Key in the x digit user code and press enter. 18

UNSETTING THE SYSTEM (TURNING THE SYSTEM OFF) PROBLEMS WHEN UNSETTING THE SYSTEM Deviation from Entry route Entering the premises via the designated route (Final exit only door), the Entry/Exit buzzer (if fitted) and keypad bleeper will sound intermittently. Deviating from the designated route e.g. opening another door will cause the sound to change to a continuous tone. On returning to the designated route the audible indication will revert to the intermittent sound, confirming that the zones have been restored to normal. (a) (b) Zones not restored during entry time If zones outside the Entry route are not restored before the Entry time expires and the x digit user code is entered using the keypad then the display will indicate FULL-SET. An alarm condition will be reported to the Alarm Receiving Centre and the keypad status LED will flash red. Deviation from the route is reported to the Alarm Receiving Centre. The display will show System FULL SET and then upon entering the x digit user code followed by enter the To obtain a system RESET refer to Page 16 keypad display will alternate between (a) and (b). 19

PROCEDURE FOR RESETTING THE SYSTEM AFTER AN ALARM ACTIVATION Carry out the following on instructions from the Alarm Company or Alarm Receiving Centre (Page 16) 3) Press CALL key and display will change to: Reset the system as follows: 1) The keypad Keypad LCD Display will show: Yes key No key 2) Press * key, then key in the x digit user code and press enter. The display will show: Call key 20 4) Press YES key. The Alarm Receiving Centre will now reset the system. Note: Whilst a RESET following an alarm activation can be carried out by the Alarm Receiving Centre Operator, a satisfactory security discipline is stipulated by the Police with their Intruder Alarm Policies as part of the Alarm Reset Procedure. This requires the cause of the alarm to be clearly described by the USER to the Alarm Receiving Centre Operator, and where it is evident that corrective maintenance is not required, a reset may be provided.

EMERGENCY DURESS An Emergency duress code will send an immediate request for help to the Alarm Receiving Centre. This should only be used in cases of forcible restraint or emergency. No indication of this alarm will be evident on the premises. To notify the Alarm Receiving Centre of an emergency duress situation key in your Duress code and press enter. The emergency alarm signal will be sent to the Alarm Receiving Centre who will alert the appropriate authority. When the appropriate Duress code is entered to send an emergency signal: 1) It will unset a full set system. 2) It will unset a part set system. 3) When the system is Unset (switched off) an emergency signal only will be sent. 21

VIEWING ALARM HISTORY LOG It is possible via the keypad display to view the system s alarm history. A maximum of 100 events are stored locally. The history log enables the user to determine the zone or device that has activated and when it occurred, since the system was last armed. If an alarm occurred while the system was armed the keypad status LED will also indicate this by flashing RED. To view the Alarm History Log after an alarm activation carry out the following: 1) Unset the system. 2) The display will show: 3) Press * on the keypad and the display will show: Previous Quit Next key key key 4) The first (most recent) event will be displayed. The next or previous events can be displayed by pressing the Previous or Next keys. 5) On completion of the examination of the History Log press the Quit key. 22

SYSTEM FAULTS MAINS POWER FAILURE In the event of a mains power failure the Alarm System will operate from the back up battery supply. The keypad status LED will flash GREEN and the Alarm Receiving Centre will be notified. The Keypad LCD Display will show: FULL-SET CONDITION PART-SET CONDITION UNSET CONDITION OR OR When the mains power supply is restored the keypad display will revert to the MAINS OK format. 23

SYSTEM FAULTS BACKUP BATTERY FAILURE Battery failure is notified to the Alarm Receiving Centre and the keypad display will show: FULL-SET CONDITION PART-SET CONDITION UNSET CONDITION OR OR If the fault persists contact the Alarm Company Service Department. 24

SYSTEM FAULTS TELEPHONE LINE FAULTS The telephone line to which the system is connected is continuously monitored for line break or line fault conditions which could affect the integrity of the System. If a telephone Line fault occurs during the Alarm Unset (Daytime) period, the keypad bleeper, and any other internal bleepers/sounders connected in the system, will operate to warn the user of this condition, and the Keypad will display: The user can cancel the audible warning by entering their normal x digit user code, whilst the keypad will continue to display the Line Fault condition. If the Line fault condition is still present when the user requires to set the system, the display will show: The system can still be FULL or PART SET by the user but will function as an audible (bells only) system. The alarm activation in this instance will not be reported to the Alarm Receiving Centre 25.

SYSTEM FAULTS TELEPHONE LINE FAULTS The setting procedure carried out is as normal with the display indicating the Line fault condition, during the system being set, e.g.: NOTE: If the Line fault condition appears to be permanent, contact the Alarm Company Service Department so that the fault can be confirmed and repaired by the Telephone Service Provider. The system will also attempt to link up with the Alarm Receiving Centre. 26

SYSTEM FAULTS TAMPER FAULTS The zone wiring and tamper switches are continuously monitored in accordance with British Standard 4737:Part 1:1986. If a tamper condition arises during the UNSET period, the fault will be audibly notified and indicated on the keypad display. If a zone tamper fault exists, the display will identify the fault: If a system tamper occurs, the display will show: If the x digit user code is now entered on the keypad the audible warning will be silenced and the display will indicate: 27

SYSTEM FAULTS WIRING FAULT CONDITIONS The system zone wiring is also monitored for correct system operation. If a fault condition arises, this will be indicated audibly in the same way as a tamper condition, and confirmed by the keypad display, e.g.: Similary, to silence the audible warning, the x digit user code is entered on the keypad, which results in the display indicating: The display indicator remains until the fault is cleared. If the fault remains and and reason is unknown then contact the Alarm Company Service Department. 28

TEST SIGNAL Following prior notification a test signal can be sent to the Alarm Receiving Centre for the following purposes: Press the * key on the keypad and the display will show: 1) Confirming the operational status of the system. 2) Obtaining a system reset following an alarm incident. To send a test signal, the system must be in the UNSET condition as shown by the display: Key in the x digit user code and press the enter key: 29 Call key History Key

TEST SIGNAL Press the Call key. The display will show: Yes key No key Press the YES key to send the test signal, the Alarm Receiving Centre Operator will notify the user as appropriate. 30

CHIME MODE (OPTIONAL FEATURE) The Chime mode option causes the keypad to bleep if a protected area is violated when the system is UNSET (switched off) or is PART SET. This will indicate when someone enters or exits a specified area. The alarm is NOT reported to the Alarm Receiving Centre. 2) Press Chime key. 3) Key in x digit user code and press enter. The display will show: To select the Chime mode carry out the following: 1) At the keypad select PART SET and the display will show: Chime key 31

CHIME MODE (OPTIONAL FEATURE) To disable the Chime mode carry out the following: 1) Select PART SET. 2) Press Quiet key. Quiet Key 3) Key in x digit user code and press enter. 32

ADVANCE SYSTEM FEATURES NOTE: To use any of the advanced system features the User will require the system master code. ADDING ADDITIONAL ACCESS CODE The user can use the keypad to program a user assigned code into the system for specific individuals, such as cleaners or temporary employees. Only one user-assigned code can be in the system at any one time. To program a user-assigned code carry out the following: 1) Ensure the system is in the UNSET condition. If not, then carry out the unsetting procedure. 2) Key in the system master code and press enter. 3) Press the System key. 4) Press the Change Code key. 5) Key in the new user-assigned code and press enter. 6) Verification of the new user code is now prompted. Key in the new user code again and press enter. NOTE: If a keypad action does not occur within 15 seconds then the display will return to the previous condition. REMOVING ADDITIONAL ACCESS CODE To remove a user assigned code from the system carry out the following: 1) Ensure the system is in UNSET. If not, then carry out the Unsetting procedure. 2) Key in the system master code and press enter. 3) Press the System key. 4) Press the Change Code key. 5) The display will prompt for a code, key in user code to be removed and press enter. 6) Press OK key. 7) The user code has now been removed. 33

ADVANCE SYSTEM FEATURES MULTIPLE PARTITION ARMING/DISARMING NOTE: For multiple partition arming, all the partitions must be programmed in the same security mode. The programming of the security mode is a function of the Alarm Receiving Centre and Alarm Company. Arming To carry out multiple partition arming carry out the following using the keypad located in Partition A. 1) Ensure the system is UNSET. If not, carry out the unsetting procedure. 2) Press Full Set key, the display will change and prompt for the master code to be entered. 3) Key in the x digit master code and press enter. 4) Press the Yes key to arm all the partitions. The display will change to setting procedure display. 5) Carry out the Full Set procedure and on completion at the keypad leave by the designated Exit/Entry route within the time limit. Disarming To carry out the following using a keypad located in any partition. 1) Key in the x digit master code and press enter. The keypad display will change to prompt a Yes/No answer. 2) Press Yes key to disarm the zones, and follow instructions shown on the keypad display. 34

ADVANCE SYSTEM FEATURES OMITTING ZONES TO ALLOW SYSTEM SETTING On entering the premises the keypad display will show: The Full Set setting procedure may be prevented by a zone fault condition (refer to page 9). To Omit the zone fault carry out the following: 1) Press Omit key and display will change to a request to enter the x digit master code. 2) Key in the master code and press enter. 3) Carry out the FULL SET procedure. The omitted zone is reported to the Alarm Receiving Centre. This display reminds the user that there is an omitted zone in the system. Note: Zones can only be omitted by master code if prearranged authority has been agreed by the Alarm Company/insurance Company. 35

ADVANCE SYSTEM FEATURES ADVANCED ALARM HISTORY This feature allows viewing of the last 100 events which have occurred for a maximum of seven days. The events include setting/unsetting and alarms. To view the alarm history: 1) Ensure the system is UNSET, if not carry out the unsetting procedure. 2) Key in the x digit master code and press enter. 3) The display will change and display a prompt to select display. 4) Select History and the last event will be displayed. Use the Previous and Next selection keys to view additional information. 5) On completion of history viewing select Quit. 36

ZST952 ISSUE 1