SPLIT WALL MOUNTED TYPE AIR CONDITIONERS INSTALLATION HANDBOOK



Similar documents
Split air conditioner Wall mounted Type Service manual

Split air conditioner Wall mounted Type. Service manual

Split air conditioner Wall mounted Type Service manual. AUS-07H53R010Px AUS-09H53R010Px AUS-09H53R150Px AUS-12H53R130Px AUS-12H53R150Px (X=1,2,3,...

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

Floor Type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MFZ-KA25VA MFZ-KA35VA MFZ-KA50VA. English

ROOM AIR CONDITIONER INSTALLATION MANUAL

Reverse Cycle Inverter Split System Air Conditioner

SPLIT AIR CONDITIONER WALL MOUNTED TYPE OWNER'S MANUAL

Portable Air Conditioner

SPLIT -TYPE ROOM AIR CONDITIONER

Ductless Split Air Conditioner

Room Air Conditioners

1. BEFORE INSTALLATION

INSTALLATION INSTRUCTIONS

LG Floor Standing Type Air Conditioner INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS SINGLE SPLIT WALL MOUNTED AIR CONDITIONER

English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL. Français. R410A Split Series. Español MODELS FTXS15LVJU FTXS18LVJU FTXS24LVJU

CENTRAL AIR CONDITIONER SPLIT SYSTEM

INSTALLATION MANUAL UH070CAV1 UH105CAV UH140CAV

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

INSTALLATION MANUAL E N G L I S H E-II-YDFC-0907 DIGITAL SCROLL SERIES AIR-CONDITIONER CEILING AND FLOOR TYPE

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Installation Manual AIR CONDITIONER (MULTI-SPLIT TYPE) Outdoor Unit RAS-5M34UAV-E1. For OUTDOOR USE only. Model name: English

Figure 2 The fan and shroud also needs to be removed for access to the four a/c compressor bolts and removal of the compressor from the top.

Inverter Room Air Conditioner Installation Manual KSV26CRE, KSV26HRE, KSV35CRE, KSV35HRE, KSV53HRE, KSV62HRE, KSV70CRE, KSV70HRE, KSV80HRE

DIGITAL SCROLL CENTRAL AIR CONDITIONER (OUTDOOR UNIT)

Inverter Air Conditioner Installation Manual. KSV25CRF, KSV35CRF, KSV70CRF, KSV25HRF, KSV35HRF, KSV52HRF, KSV70HRF, KSV80HRF Refrigerant R32

Split Air Conditioner

Umeda Center Bldg., 4-12, Nakazaki-Nishi 2-chome, Kita-ku, Osaka, Japan 3SB Manager Quality Control Department

INFRARED QUARTZ WALL HEATER

CEILING CASSETTE TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

AIR-CONDITIONER SPLIT TYPE

Hi Wall Split Air Conditioners

CENTRAL AIR CONDITIONER SPLIT SYSTEM

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

AIR CONDITIONER INSTALLATION MANUAL

Wall Mounted Mini Split Heat Pump Air Conditioner

XL PREMIUM OIL COOLER KIT

CEILING CASSETTE TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS

MAC-821SC-E. Centralized On-Off Remote Controller. English ÏÏËÓÈÎ. Русский [FOR INSTALLER] INSTALLATION MANUAL

Cooling system components, removing and installing

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

AIR CONDITIONER INSTALLATION MANUAL

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

ACDC12 Solar Air Conditioner Heat Pump

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Split-type Air-Conditioner

Installation Instructions

AIR CONDITIONER INSTALLATION MANUAL

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

CEILING DUCT TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL

AIR CONDITIONER (SPLIT TYPE)

Room Air Conditioner SERVICE MANUAL. website CAUTION

CU-2E15LBE CU-2E18LBE CU-3E18LBE CU-4E23LBE

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03

PORTABLE AIR CONDITIONER

Cylinder head gasket, replacement

S4(75-82,91)WM_ENGLSH_120709A

CEILING CASSETTE DUCTLESS SYSTEM

DUCTED SPLIT TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS

LG Room Air Conditioner INSTALLATION MANUAL

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

PARTS NEEDED FOR CONVERTING FROM LP TO NG

Air Conditioner Water Heater Model ACWH18

Installer s Guide 18-AH39D1-13

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Cooling system components, removing and installing

SPLIT TYPE ROOM AIR CONDITIONER INSTALLATION MANUAL (P/N ) (MODEL: MW18Y3F/MR18Y3F, MW18C3F/MR18C3F)

AIR CONDITIONER OUTDOOR UNIT

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Geyser-R Heat pump water heater Installation manual

Installation Manual. BYD Wall-mounted AC Charging Box

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

Manual for the Installation of

REMOVAL AND INSTALLATION

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

AIR CONDITIONER INSTALLATION MANUAL ENGLISH FRANÇAIS ESPAÑOL

CASSETTE Split System, 18,000-48,000 Btu/h Under ceiling T ype MCC Series 50 Hz

Air Conditioner Duct Construction & Repair

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Installation Instructions For Slider Casement Air Conditioners

INSTALLATION INSTRUCTIONS FOR INTERNATIONAL 9000 SERIES ROOF TOP AIR CONDITIONERS

LUCCI AIRFUSION QUEST II CEILING FAN

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

AIR CONDITIONER OUTDOOR UNIT

INSTALLATION MANUAL. Free Joint Multi & Multi-Split Type Room Air Conditioner (Cooling and Heating) MH18VF1X MH19VF1X

Installation Guide. 5 Series 15 W. Undercounter/Freestanding Nugget Ice Machine

INSIDE ENGINE COMPARTMENT TOYOTA AIR CONDITIONING ENGLISH EUROPE,GENERAL,AUSTRALIA

3 IN 1 BATHROOM HEATER

AIR CONDITIONER INSTALLATION MANUAL

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

orlando OWNER S MANUAL

Transcription:

SPLIT WLL MOUNTED TYPE IR CONDITIONERS INSTLLTION HNDBOOK Thank you for choosing our ir Conditioner. Please read this INSTLLTION HNDBOOK carefully prior to installing and keep it for further reference. Do not attempt to install, maintain the ir Conditioner by yourself. Incorrect behaviour may cause fire, electric shock and the unit falling may result in injury or water leakage. Contact our designated air conditioner service centre and specialists. The manufacturer shall not assume responsibility for accidents or injury caused by incorrect behaviour. This product must not be disposed together with the domestic waste. This product has to be disposed at an authorized place for recycling of electrical and electronic appliances.

CONTENTS Contents Installation sketch Installation instructions 1 3 Installation of the indoor unit Securing the mounting plate Wiring Installation of the drain hose Installation of the indoor unit Pipe connection rrangement of the drain hose Wall sealing and Pipe fastening 3 4 4 5 5 5 5 Installation of the outdoor unit Wiring Installation of the drain joint Joint of the connecting pipe ir exhausting Process of flared tube dding refrigerant Operation test 6 9 9 9 9 10 10 1

TO INDOOR UNIT TO INDOOR UNIT TO INDOOR UNIT INSTLLTION SKETCH Confirm the installation position by the mark of the indoor mounting plate. above 105mm above 155mm above 50mm Note:Different models have different mounting plates, the installing charts of this book are presented just for the purpose of illustration, please take the real objects as reference. The connecting pipe can be led from back, right, underside, or left-back side. Notice: do not raise the drain hose. bove 0mm back right back underside front left left-back ttention: The allowable length of the connecting pipe is 10m. The allowable distance between indoor unit and outdoor unit is 5m. While installing the pipeline on the thin armor plate or on the wall of metal mesh, you should use the wooden board to clamp between the wall and the pipeline, or wrap up the pipeline with 7-8 layers of insulating plastic tape. Cover connecting pipe with adiabatic material. Sponge plastic adiabatic material with the thickness of 8mm. above 300mm above 300mm 100mm 以 上 Single Split Model above 300mm above 300mm bove 500mm TO BINDOOR UNIT Dual inverter Model B B above 300mm above 300mm TO BINDOOR UNIT B OR above 300mm bove 500mm above 300mm TO BINDOOR UNIT Dual Split Model

INSTLLTION INSTRUCTIONS 1 Location of indoor unit Keep the air inlet and outlet at a far distance from the blockage. Keep the height distance between the indoor and outdoor unit at most 5m. Mount on the wall solid enough to bear the weight of the unit and not cause any shake. void direct sunshine. place easy for condensate drain and easy for connecting with the outdoor unit. Keep a far distance away from the fluorescent lamp, it may influence the operation of remote controller. Keep at least 1m away from the TV radio and other home appliances. Location of outdoor unit place for firm location of the unit, solid enough to bear the weight of the unit and not cause any shake. Good ventilation, less dust, far from direct rain and sunshine. place where the air discharged out of the outdoor unit or the operation noise will not annoy your neighbours. No blockage near the outdoor unit. void places close to inflammable gas leakage. INSTLLTION OF THE INDOOR UNIT 1 Securing the mounting plate and drill on the wall Note:Different models have different mounting plates, the installing charts of this book are presented just for the purpose of illustration, please take the real objects as reference. Secure the mounting plate The mounting plate should be attached to the structural part of wall (post etc). 105mm or more from sidewall fasten string at the central hole at least 50mm 155mm or more from sidewall Tapping screw ST4 5(5) mounting plate plumb NOTICE: The holes at solid arrow position must be secured to avoid the shake of mounting plate. When the expansion bolts are used, two holes ( 11 0 or 11 6 ) that the distance between them is 450mm should be adopted. 3

Drill on the wall Center of hole( 65mm ) Pipe hole Center of hole( 65mm ) 3 Operation: 1.Confirm the position of the wall hole according to the chart (If it need to orientat a hole on the left side of the mounting plate, please refer to the method of orientating the right wall hole in the above chart)..use the aiguille to drill a hole with a diameter of 65mm. Wiring Open the front grille; Remove the screw from electrical box cover, pull the electrical box cover away from the unit and set aside. Screw Remove the screw from fastener, pull the fastener away from the unit and set aside. Connect the. Replace the fastener and electrical box cover. Installation of the drain hose NOTE: The drain hose must be arranged beneath the connecting pipe. Drain hose The drain hose must not be hunched or twisted. While wrapping up the drain hose, do not pull it. The drain hose through the room must be wrapped up by the thermal insulation materials. The connecting pipe and the drain hose must be wrapped up by felt felt strip. diabatic pad should be used at where the pipe contacts the wall. ROUTE OF PIPE If pipe comes out of the right side of the indoor unit, cut part 1 of the unit; If pipe comes out of the lower-right side of the indoor unit, cut part of the unit; If pipe comes out of the left side of the indoor unit, cut part 3 of the unit. 1 Diagram Liquid pipe NOTE: The appliance shall be installed in accordance with national wiring regulations. The appliance must not be installed in the laundry. The appliance must be installed.5m above the floor. The appliance must be positioned so that the plug is accessible. For some models whose cooling capacity are above 4600W (17000BTU/h), an all-pole disconnection device which has at least 3mm separation distance in all pole and a residual current device(rcd)with the rating of above 10m shall be incorporated in the fixed wiring according to the national rule. gas pipe diabatic underlay 3 4

4 REFIT OF DRIN HOSE If pipe comes out of the left side of the indoor unit, the drain hose must be refitted, otherwise water leakage may occur. Readjustment methods: Interchange the position of drain hose and drain rubber plug. Clearance is not allowed after refit, it would lead to water leakage. Installation of the indoor unit Indoor unit drain hose Drain rubber plug Let pipe go through the wall hole and attach the indoor the mounting plate unit to the mounting plate.(press the rib of indoor unit inside the hook of the mounting plate.) Bottom the rib of indoor unit 5 Pipe Connection The number of bent position of the pipe in the indoor unit should not exceed 10. The number of bent position of the pipe in the indoor unit and the outdoor unit should not exceed 15. The radius of bent position should be more than 10cm. Please break the evaporator craft tube with pincers before connecting. fter exhausting the inside air, use the wrench to twist down the nut of connecting tube of the evaporator. (Fig. 1) Put some seal oil to cover the joint and the flare. lign the centre of joint in line with that of flare and tighten the nut of connecting pipe with wrench. (Fig. ) ttention: Do not exhaust the inside air just by loosing the nut since there is the air of certain pressure inside the tube of indoor unit. Please do not make extra effort for fear of damaging the expansion orifice. 6 DIMETER OF PIPE φ6/ φ6.35mm(1/4") φ9/ φ9.5mm(3/8") φ1/ φ1.7mm(1/") φ15/ φ15.88mm(1/") TORQUE(N m) 1.0---15.0 33.0---36.0 40.0---45.0 73.0---78.0 rrangement of the drain hose Evaporator craft tube (Fig. 1) (Fig. ) To drain the condensate water easily, the drain hose should be declined downwards. The following 5 arrangement methods are incorrect. 7 Decline downward Water leak Decline downward Water leak Standing water (Fig. 1) (Fig. ) (Fig. 3) (Fig. 4) air Water leak If you find the drain hose not long enough to connect with the indoor unit, you can extend it with the hoses in the accessory box. The drain hose through the room must be wrapped up with the special adiabatic material. Wall sealing and Pipe fastening Use putty to seal the wall hole. Use clamp (pipe fastener) to secure the pipe at specified position. Dip hose into water 50mm or less above floor (Fig. 5) Drain hose Hose(ID 15cm) PVC hard seal with putty secure the connecting pipe with clamp get rid of unwanted part clamp 5 indoor unit screw

INSTLLTION OF THE OUTDOOR UNIT 1 Wiring OR Single Split Model Dual Split Model Wiring For bove 6000W Model (bove 1000BTU/h Model) 1 Remove the self-tapping screws ( pcs) onthe maintenance board and take out the maintenance board. The wire can be led from the back hole of the piping hole or ejecting hole. Please utilize outdoor pipe support when the wire is led from the backside. Terminal board Fix the wire with anchor Maintenance board Piping cover Outdoor pipe support (Outdoor pipe support is not required when leading the wire from other places). Loosen the self-tapping screws ( pcs) on the fixing clip to loosen the fixing clip. 3 Loosen the fixing screw of the wire terminal board, pass the power wire and signal wire through the fixing clip. Then firmly fix the power wire and signal wire on the terminal board with the fixing screw. (Earth wire must be connected firmly.) 4 Tighten the self-tapping screw on the fixing clip. 5 Install the maintenance board. fter the pipes and wire are installed, please seal the sponge block as per drawing indication. Maintenance board Back wiring Piping cover Right wiring Piping cover Ejecting hole Sponge 6

Connect diagram 1500-4600W Model (5000-1000BTU/h Model) N N 3 4 Plug housing 1 N 3 4 Plug housing 1 N Cool only type Outdoor unit terminal N 3 4 R1R Gray OR N 3 4 Gray Plug housing L N L3 N Cool only type N N Cool only type 5000-5100 W Model N 3 4 N 3 4 L1 L L1 L L L 3 4 R1 5 R 6 Plug housing 1 Plug housing Gray (17000-18000BTU/h Model) OR N 3 4 N 3 4 Plug housing 1 Plug housing OR 6000-7000W Model (1000-4000BTU/h Model) L N 3 L3 N Gray Plug housing 1 OR L N 3 Gray L N 3 4 Plug housing 1 N 3 4 N 3 4 R1R L N N L Plug housing 1 Gray Plug L1 L Outdoor unit L L3 N L N 3 4 R1 5 R 6 housing terminal N POWER N POWER L SOURCE LSOURCE Cool only type (T3) 安 装 说 明 Plug housing 1 (T3) Inverter Type N L Plug housing 1 Dual Split Inverter Type Indoor unit terminal Indoor unit B terminal L N L N Dual Split Model Indoor unit terminal Indoor unit B terminal L N L N 7 Power source L N L NB L N Plug housing Outdoor unit terminal Power source L NB Cool only and heat pump type Outdoor unit terminal

Notice: If not include the connect diagram you need, please see the wiring diagram. If you find the color of connecting not comply with the top diagram, please take real objects as major reference. But the terminal of the same sign must be joint with the connecting of the same color. The plug housing 1 is connected to the matched receptacle housing of the indoor unit. The plug housing is connected to the matched receptacle housing of the outdoor unit. If the signal wire has to be bought separately, choose electric wire above 0.75mm. If the interconnection cord for power supply has to be replaced, please see the following table for reference. MODEL SPECS (Interconnection cord) 700W(10000BTU/h) 1.0mm 300W(11000BTU/h) -4000W(15000BTU/h) 4500W(16000BTU/h) -8000W(8000BTU/h) 1.5mm.5mm 8500W(9000BTU/h) -9500W(3000BTU/h) 10000W(34000BTU/h)-11000W(38000BTU/h) 4.0mm 6.0mm WRNING: Please take the electric circuit diagram attached to the indoor/outdoor units as major reference while installing. The power wire and signal wire between the indoor/outdoor units must be connected one by one as per corresponding number on the wiring terminal board. The connecting s must be clipped together. Special must be used to connect indoor unit and outdoor unit. It should be ensured that the terminals are not influenced by external force. Poor connection may cause fire. The electric box cover must be mounted and secured in position, otherwise fire or electrical shock may occur because of dust or moisture. The temperature of refrigerant circuit will be high, please keep the interconnection away from the connecting tube. ll the models shall be connected with the mains which has system impedance limitations. While installing the unit, please see the following table for impedance information or consult with the supply authority.(the following information and specifications are subject to change without prior notice due to continuing research.) 8 SERIES MODEL IMPEDNCE R series R407C series R410 series 6800W (4000BTU/h) 5100W (18000BTU/h) 3500W (1000BTU/h) 300W (11000BTU/h) 500W (9000BTU/h) 6500W (000BTU/h) 5100W (18000BTU/h) 3500W (1000BTU/h) 3300W (11500BTU/h) 300W (11000BTU/h) 500W (9000BTU/h) 000W (7000BTU/h) Dual Split Model(5+5) Dual Split Model(5+35) 6800W (4000BTU/h) 5100W (18000BTU/h) 0.116Ω 0.160Ω 0.31Ω 0.31Ω 0.467Ω 0.04Ω 0.16Ω 0.148Ω 0.11Ω 0.11Ω 0.33Ω 0.30Ω 0.187Ω 0.138Ω 0.14Ω 0.68Ω

Installation of the drain joint (only for heat pump type) 3 Insert the outdoor double-channel drain joint in one of the bottom holes of the suitable size then connect drain hose and joint together. Joint of the connecting pipe Put some seal oil to cover the joint and the flare. Bottom Double-channel drain joint Drain hose 4 lign the centre of joint in line with that of flare and tighten the nut of connecting pipe with wrench. ( djust the torque by the same method of connecting pipe for indoor unit.) ir exhausting Screw down the cap of both gas shut-off valve and liquid shut-off valve as well as the nut of service port. Use llen wrench to turn the valve cork of liquid side at 90 counter-clockwise, and close it after 10 seconds. Use soapy water to check the gas leakage especially at all joint. If there is no gas leakage, please turn the valve cork of liquid side at 90 counter-clockwise again. Press the cork of service port at gas shut-off valve, 10 seconds later, when you see foggy gas discharged, that means inner air is exhausted out. Use llen wrench to turn the valve cork of both liquid shut-off valve and gas shut-off valve counter-clockwise until they are completely open and then replace the valve caps and tighten them. 5 Process of flared tube Use the pipe cutter to cut off the broken part of flare. liquid shut-off valve gas shut-off valve liquid connecting pipe service port service port cap allen wrench gas connecting pipe valve nuts Notice: Do not vent refrigerant into atmosphere: refrigerant is a fluorinated greenhouse gas, covered by Kyoto protocol, with a Global Warming Potential (GWP) =1900(R410)/1600(R407C)/1700(R). Remove burrs at the cut of the flare. Insert a nut into the connecting pipe and do flaring with specified flaring tools, reamers for example. pipe 90 Oblique Roughness Burr Outer diameter φ6/ φ6.35mm(1/4") φ9/ φ9.5mm(3/8") φ1/ φ1.7mm(1/") φ15/ φ15.88mm(1/") (mm).0--.5 3.0--3.5 3.5--4.0 4.0--4.5 Burr D Reamer Check the quality of flaring technique. pipe 9

6 dding refrigerant If the connecting pipe is longer than 7 metres, add refrigerant as needed. (Cool only type) added amount =(Lm-7m) 15g/m ; ()added amount = (Lm-7m) 50g/m. ( : amount of added refrigerant, L: the length of connecting pipe) The length of connecting pipe (m) (Cool only type)added amount (g) ()added amount (g) 7 0 0 8 15 50 9 30 100 10 45 150 Exhaust the air as the above-mentioned method. Screw the gas shut-off valve to close, connect charging hose(low pressure) to the service valve and then open gas shut-off valve again. Connect the refrigerant bottle to the charging hose and then convert it. Manifold gauge Low pressure valve Pressure meter High pressure valve Charging line Fill in liquid refrigerant as the above table. Disconnect the manifold gauge after turning off the Service port shut-off valve, and then open gas shut-off valve again. Tighten nuts and caps of each valve. 7 Operation test Before test operation, wiring safety inspection must be carried out carefully again. 1. Emergency switch operation: Every press of emergency switch, the air conditioner runs as in the following order: Cool only type: Cool Shut off : Cool Heat Shut off. Remote controller operation: If the indoor unit sounds like Di, Di when pressing I/O button, that indicates the air conditioner is under the operation of remote controller. fter that, press every button to test their functions. 10

KG-04