Effective Date: October 2015 Void After: October 2016. Product: Water Closets with Dual Flush Feature File No. 5319



Similar documents
Effective Date: March Rev. 5/29/2015- Void After: March Product: Ceramic Plumbing Fixtures File No. 3360

Effective Date: September 2015 Void After: September Product: Shielded Transition Couplings File No. 5794

PLEASE NOTE. For more information concerning the history of these regulations, please see the Table of Regulations.

LOS ANGELES DEPARTMENT OF WATER AND POWER. Requirements for Ultra-Low-Flush Toilets. Supplementary Purchase Specification to ASME A

Georgia State Amendments to the International Plumbing Code

DIVISION: PLUMBING SECTION: DOMESTIC WATER PIPING REPORT HOLDER: CURAFLO IP LLC 4035 E. OASIS STREET MESA, AZ 85215

SECTION COMMERCIAL PLUMBING FIXTURES

THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS: Section 1. Article V of Chapter XII of the Los Angeles Municipal Code is added to read:

High-Efficiency Plumbing Fixture Direct Install Water Savings Analysis

Research of Grey Water for Use in Residential Applications Original date of publication: Updated:

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

(a) Purpose. The purpose is to safeguard potable water supplies by preventing backflow into public water systems.

F1000 VITREOUS CHINA URINAL BENEFITS FEATURES

ICC EVALUATION SERVICE, LLC, RULES OF PROCEDURE FOR EVALUATION REPORTS

Hommage 2 PIECE WATER CLOSET BOWL MODEL TANK MODEL 7721 U1 SEAT MODEL

Page 1 of 51 Exterior Plumbing Quiz Part 1

PERMITS REQUIRED & PERMIT EXEMPTIONS

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

SECTION 105 PERMITS. 2. Fences not over 6 feet (1829 mm) high. 3. Oil derricks.

JB ENGINEERING AND CODE CONSULTING, P.C Cardinal Drive Munster, IN Phone: Fax:

CHAPTER 29 PLUMBING SYSTEMS. [P] TABLE MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES a (See Sections and ) 1 per 40 for the

NEW JERSEY ADMINISTRATIVE CODE Copyright 2013 by the New Jersey Office of Administrative Law

Emergency Showers and Eyewashes Mike Adkins Wednesday, October 31, 10:00-11:1511:15 a.m.

What to Expect From the Examination. How to Study the Plumbing Codes

newenergylabel.eu The new European energy label: the success story continues

Warranty Terms. QLogic-provided cables, optics and other accessories are warranted for ninety (90) days from date of purchase.

Install a bathroom anywhere without any major construction

Editorial Note: bold and underline denotes added text, strikethrough denotes deleted text

Chapter 7 Plumbing Connections

2-1 TITLE 7 CONSTRUCTION REGULATIONS 2-4

How to Locate and Stop Costly Water Leaks

The Impacts of High Efficiency Toilets on Plumbing Drainlines and Sewers

City of Modesto WATER-USE HOME SURVEY

Water Distress in Growing Cities Issues & Challenges. Presented by: Neeta Sharma Managing Director IAPMO India

WaterSense or Energy Star. Tank type toilets: WaterSense = 1.28 gpf (4.8L) with at least 350 gram waste. 1.5 gpm maximum & 0.8 gpm minimum at 20 psi

Installation Instructions

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

MARICOPA COUNTY ENVIRONMENTAL HEALTH CODE

Twist/Sunberry 2 PIECE WATER CLOSET BOWL MODEL 5C02 01, 5C03 01, 5C04 01, 5C05 01

When Should Examination Preparation Begin?

Brian Coppock, Regional Compliance Officer. Office of Statewide Health Planning and Development Facilities Development Division

Green Plumbing and Mechanical Code Supplement

Plumbing Code in Commercial Kitchens

MANAGEMENT SYSTEM CERTIFICATION CONDITIONS & USE OF THE CERTIFICATION MARK

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

Safety, Health and Accessibility Design Guidelines For Architects, Engineers and Design Firms

WHITE PLAINS PLUMBING CODE PART 1. GENERAL REQUIREMENTS

BLADDER SURGE CONTROL SYSTEM

Installation Instructions

The Passenger Car (Fuel Consumption and CO 2 Emissions Information) Regulations

Franklin County Public Health Regulation 103 Plumbing. Section Plumbing for Commercial, Public, and Residential Buildings, or Places

The New Paradigm for Medical Device Safety. Addressing the Requirements of IEC Edition 3.1

water regulation facts The Water Supply Regulations The Water Supply (Water Fittings) Regulations 1999 What are they, and how do they affect you?

FLUSHMATE FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual 503 and 504 Series

APPLICATION FOR GRAYWATER IRRIGATION SYSTEM PERMIT SIMPLE RESIDENTIAL GRAVITY SYSTEMS, NO STORAGE

Page 1. Description

Chapter PLUMBING CODE

CITY of LOS ANGELES DEPARTMENT of BUILDING and SAFETY

ANSI / ISEA Z Compliance Checklist

GENERAL PLUMBING REQUIREMENTS

FUTRUS WALL-MOUNT VANITY SINK SOLUTIONS WITH DUPONT CORIAN

CHAPTER 29 PLUMBING SYSTEMS

Top 10+ Mistakes of DWV plumbing design

Date of Authorization November 30, 2006 BMEC Authorization Number BMEC Application BMEC A AUTHORIZATION REPORT The AcornVac System

Leak Detector Guide. Your Guide to Home Water Conservation

DVS01. VacuFlush Status Panel. Instruction manual. vierstufige Füllstandsanzeige Einbauanleitung... 13

STANDARD PLUMBING AND DRAINAGE REGULATION 2003

Supplier Quality Assurance

Basic Principles for Sizing Grease Interceptors

LEAK DETECTION GUIDE

PLUMBING ROUGH IN INSPECTION

MP L BAR SEALER & SHRINK TUNNEL COMBO SYSTEM QUOTE

What is Thermal Expansion?

AMERICAN SOCIETY OF CERTIFIED ENGINEERING TECHNICIANS

Grease Interceptor. If it s a. then why not size by grease production? Presented by: Sean Duffy. Schier Products Company 2012

Instruction Guide for Cleaning, Testing, and Packaging Kendall SCD 700 Sequential Compression System Controller and Tubing Set

National Institute of Justice

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

SUPPLIER QUALITY PROGRAM, V (U)

Section 4 EMERGENCY EYEWASH AND SAFETY SHOWER EQUIPMENT

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS

Water/Sewer Billing, Metering, and Water Efficiency. May 3, 2011

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Plumbing Code Statutes and Regulations February 2011 Labor Standards and Safety Division Mechanical Inspection

Sealant. 30" Model No D: 17-7/8" TO 18-3/8" (454 to 466mm) W: 29-3/4" TO 30-1/4" (756 to 768mm) Under Countertop Installation

REMOTE TECHNOLOGIES INCORPORATED DEALER AGREEMENT

Plumbing Fixture Replacement (SB 407) for Existing Single-Family Residential, Multifamily Residential and Commercial Buildings

ADA Design Guide Washrooms & Showers

AIRCRAFT FUEL PUMP & PARTS PRICE LIST

Transcription:

IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the requirements of applicable codes and standards. This activity is coupled with periodic surveillance of the supplier's factory and warehouses as well as the assessment of the supplier's Quality Assurance System. This listing is subject to the conditions set forth in the characteristics below and is not to be construed as any recommendation, assurance or guarantee by IAPMO Research and Testing, Inc. of the product acceptance by Authorities Having Jurisdiction. The most updated information on this Certificate of Listing is available online at pld.iapmo.org Effective Date: October 2015 Po Box 33178 Palm Beach Gardens, FL 33420 Identification: Water Closets with Dual Flush Feature shall be marked with the manufacturer's name or registered trademark, or in the case of private labeling, the name of the customer for whom the fixture was manufactured. Markings shall be permanent, legible, and visible after installation. The model number of close-coupled water closets shall be marked on both the tank and the bowl. Water closets with Dual Flush Feature shall be marked to identify the average water consumption, expressed in litres and gallons per flush. The litre or gallon value may be stated first, at the manufacturer's option. The product shall be marked with the reduced flush volume and the designation ASME A112.19.14 to signify compliance with this Standard. The location of this mark shall be determined by the manufacturer and is not required to be permanent, but it shall be visible after installation. The label shall be intended for removal by the occupant This listing period is based upon the last date of the month indicated on the Effective Date and Void After Date shown above. Any change in material, manufacturing process, marking or design without having first obtained the approval of the Product Certification Committee, or any evidence of non-compliance with applicable codes and standards or of inferior workmanship, may be deemed sufficient cause for revocation of this listing. Production of or reference to this form for advertising purposes may be made only by specific written permission of IAPMO Research and Testing, Inc. Any alteration of this certificate could be grounds for revocation of the listing.

Page 2 only, and this shall be so stated on the label. Gravity flush tanks shall be marked with a water level mark or with the information necessary to determine the water level in the tank needed to deliver the intended flush volume. This mark shall be applied to the ceramic body of the tank, the tank liner, or the flush valve overflow tube. The vertical distance between the water level mark and the lowest point of the tank overflow channel shall not exceed 38 mm (1.5 in). Water closet tanks shall have a label indicating at least the following: (a) the telephone number or contact information of a service department from which end-users can obtain replacement parts; (b) the serial or part number of the flush valve seal; and (c) information on procuring replacement parts for maintaining the original flush volume. All packaging shall be marked with the manufacturer's name or registered trademark; or in case of private labeling, the name of the customer for whom the fixture was manufactured and the model number. Packaging shall be marked with the water consumption in gpf and Lpf. Each fixture shall be marked with the cupc certification mark. In the case where the tank and the bowl are sold separately, both shall have the certification mark. Identification of flush mode options shall be depicted on the actuator. This identification shall be either by graphic display or lettering, or shall be intuitively apparent. Fixtures that require proprietary (i.e., non-standard) components, e.g.,

Page 3 supply fittings, waste fittings, or water closet seats, shall indicate, in the packaging or the accompanying literature, that such components are provided by the manufacturer and shall identify the proper replacement parts. Fixtures that do not comply with one or more of the dimensional requirements of this Standard shall be marked with an "N" to indicate the non-standard nature of the fixture. Characteristics: To be installed in accordance with the manufacturer's instructions, the latest edition of the Uniform Plumbing Code, and the National Plumbing Code of Canada. Products listed on this certificate have been tested by an IAPMO R&T recognized laboratory. This recognition has been granted based upon the laboratory's compliance to the applicable requirements of ISO/IEC 17025. Products are in compliance with the following code(s): Uniform Plumbing Code (UPC ) National Plumbing Code of Canada International Plumbing Code (IPC ) Products are in compliance with the following standard(s): ASME A112.19.2-2013/CSA B45.1-13 including Update No. 1 dated October 2013 and ASME A112.19.14-2013

Page 4 Models: Note: Models preceded by an * are also in compliance with ANSI A117.1. Model No. Description 4352.XX Cascade, Round, 0352 Bowl/1312 Tank, HET 4352J Combination Cascade RF 0352J Bowl and 1312HE Tank Dual Flush HET 4352JL.XX Combination Cascade RF 0352J Bowl and 1312L 12" Dual Flush Tank w/liner HET 4352JR.XX Combination Cascade RF 0352J Bowl and 1312R 12" Dual Flush Tank Right Lever HET 4353.XX Cascade, Elongated, 0353 Bowl/1312 Tank, HET 4353J Combination Cascade EF 0353J Bowl and 1312HE Tank Dual Flush HET 4353JL.XX Combination Cascade EF 0353J Bowl and 1312L 12" Dual Flush Tank w/liner HET 4353JR.XX Combination Cascade EF 0353J Bowl and 1312R 12" Dual Tank Flush Right Lever HET 4354J Combination Cascade ADA 0354J ADA Bowl and 1312HE Tank Dual Flush HET *4354.XX Cascade, Elongated, 0354 ADA Bowl/1312 Tank, HET *4354JL.XX Combination Cascade 0354J ADA Bowl and 1312L 12" Dual Flush Tank w/liner HET *4354JR.XX Combination Cascade 0354J ADA Bowl and 1312R 12" Dual Tank Flush Right Lever HET 4361J.XX Combination Cascade RF 0352J Bowl and 1301 10" Dual Flush Tank HET 4362J.XX Combination Cascade EF 0353J Bowl and 1301 10" Dual Flush Tank HET *4363J.XX Combination Cascade 0354J ADA Bowl and 1301 10" Dual Flush Tank HET 4364J.XX Combination Cascade RF 0352J Bowl and 1304 14" Dual Flush Tank HET 4365J.XX Combination Cascade EF 0353J Bowl and 1304 14" Dual Flush Tank HET *4366J.XX Combination Cascade 0354J ADA Bowl and 1304 14" Dual Flush Tank HET 7531.XX Aine 7531 WHBO bowl for use with Geberit Model 111 7532.XX Fionn 7532 WHBO bowl for use with Geberit Model 111 Suffixes: XX = 01 White = 02 Bone = 03 Biscuit

Page 5 ADDITIONAL COMPANY INFO: Ferguson Enterprise, Inc. Model No. (bowl #/tank #) Description PF9300WH/PF9312WH Dual Flush, Round Front, White, HET PF9301WH/PF9312WH Dual Flush, Elongated Front, White, HET *PF9303WH/PF9312WH Dual Flush, Elongated Front, White, HET PF9300JWH PF9300JWH RF Bowl and PF9312WH Tank PF9301JWH PF9301JWH EF Bowl and PF9312WH Tank PF9303JWH PF9303JWH ADA Bowl and PF9312WH Tank PF9300J.XX/PF9312R.XX Dual Flush, Round Front Bowl, 12" RI Tank w/right Lever HET PF9301J.XX/PF9312R.XX Dual Flush, Elongated Front Bowl, 12" RI Tank w/right Lever HET *PF9303J.XX/PF9312R.XX Dual Flush, ADA, Elongated Front Bowl, 12" RI Tank w/right Lever HET PF9300J.XX/PF9312U.XX Dual Flush, Round Front Bowl, 12" RI Tank w/liner HET PF9301J.XX/PF9312U.XX Dual Flush, Elongated Front Bowl, 12" RI Tank w/liner HET *PF9303J.XX/PF9312U.XX Dual Flush, ADA, Elongated Front Bowl, 12" RI Tank w/liner HET PF9300J.XX/PF9310.XX Dual Flush, Round Front Bowl, 10" RI Tank HET PF9301J.XX/PF9310.XX Dual Flush, Elongated Front Bowl, 10" RI Tank HET *PF9303J.XX/PF9310.XX Dual Flush, ADA, Elongated Front Bowl, 10" RI Tank HET PF9300J.XX/PF9314.XX Dual Flush, Round Front Bowl, 14" RI Tank HET PF9301J.XX/PF9314.XX Dual Flush, Elongated Front Bowl, 14" RI Tank HET *PF9303J.XX/PF9314.XX Dual Flush, ADA, Elongated Front Bowl, 14" RI Tank HET MIRML220.XX Aine 7531 WHBO bowl for use with Geberit Model 111 MIRVL220.XX Fionn 7532 WHBO bowl for use with Geberit Model 111 PF1400T.XX/F9312R.XX PF1400T.XX/PF9310.XX PF1400T.XX/PF9312.XX PF1400T.XX/PF9312U.XX PF1400T.XX/PF9314.XX PF1401T.XX/PF9310.XX PF1401T.XX/PF9312.XX PF1401T.XX/PF9312R.XX PF1401T.XX/PF9312U.XX PF1401T.XX/PF9314XX PF1403T.XX/PF9310.XX PF1403T.XX/PF9312.XX PF1403T.XX/PF9312R.XX PF1403T.XX/PF9312U.XX PF1403T.XX/PF9314.XX Suffixes: XX = WH White = BO Bone = BS Biscuit