DENVER MODEL 30 X 30 SPECIFICATIONS



Similar documents
COLORADO MODEL. 35 x 65 SPECIFICATIONS

ATLANTA MODEL SPECIFICATIONS

Preformed Metal Roofing and Siding

2. Division 05 Structural Steel Framing for steel framework requirements

A. The shade structure contractor shall be responsible for the design, engineering, fabrication, and supply of the work specified herein.

SECTION STANDING SEAM METAL ROOF

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

GUIDELINE SPECIFICATIONS

SECTION PREFORMED METAL STANDING SEAM ROOFING

VALOR STEEL BUILDINGS STANDARD SPECIFICATIONS

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

SECTION 1 GENERAL REQUIREMENTS

238T Standing Seam Metal Roof System (SSMRS)

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

Nucor VR16 II TM Vertical Rib Standing Seam Roof System

SECTION ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS

1.02 SYSTEM DESCRIPTION

Chapter 3 Pre-Installation, Foundations and Piers

PRODUCT SPECIFICATIONS

SECTION COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

Standing Seam Roof Systems

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

SECTION GROUND WATER STORAGE TANKS

Sports and High Mast Lighting Poles Phone: (866) Fax: (817)

Installation Manual for STANDING SEAM ROOFING

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Commercial And Industrial Steel Buildings

ABSeam Panel Overview and Installation Instructions

METAL BUILDING SYSTEMS

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec Master Spec Page 1

MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

Model # 940P-V6. Page 1 of 11

Mechanical Installation

PART 1 GENERAL 1.1 SECTION INCLUDES

COMMONLY USED RESIDENTIAL BUILDING CODES

Additions and Alterations

The Butler MR-24 Standing Seam Roof Difference. A comparison between metal roof systems

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

SECTION STANDING SEAM METAL ROOFING

Sapa: SECTION ARCHITECTURAL ALUMINUM HANDRAILS AND RAILINGS

STANDARD OPEN PATIO COVER

Materials. Estimating Steel. Players. Materials. Shop Drawings. Detailing Process. Standard shapes. Fabricated members, Built-up sections

HIGH TENSION CABLE BARRIER

SECTION STORM DRAINAGE SYSTEM

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

SPECIAL INSPECTION AND TESTING AGREEMENT INTERNATIONAL BUILDING CODE

CHAIN-LINK FENCES BID SPECIFICATIONS DESCRIPTION

P.A.L. S SPECIFICATIONS

Wastewater Capital Projects Management Standard Construction Specification

RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE

Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems

VERTICAL LOCK Table of Contents

This digital document created and presented by Richard Fleetwood. He is the. Civil Defense Now! ( websites.

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

How to secure your property after a disaster

SECTION WINDOW WASHING SYSTEMS

DESIGN CLARIFICATION (DC)

SECTION FIRE HYDRANTS

PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE

REQUEST FOR QUOTE. Material $ Labor/Installation $ tax $ Total $ Material $ Labor/Installation $ tax $ Total $

Metal Building Systems Installation and Flashings & Details Guide. Table of Contents

PANELIZED HOME INSTALLATION GUIDELINE

Display hidden notes to specifier. (Don't know how? Click Here) A. Advanced Upcoiling Security Grilles, power operated.

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

LOWELL REGIONAL WASTEWATER UTILITY SPECIFICATIONS FOR THE LOWELL MA CONCRETE FLOODWALL REPAIRS

Residential Metal Roofing

Solar Water Heating and Solar Electric Generators Installed on One or Two Family Dwellings

CB-100 CB-150 CS-100 SL-100 SL-150 SLZ-1000

OGi Architectural Metal Solutions

IF YOU NEED A POLE BARN OR DIY KIT CALL NOW AND LETS MAKE A DEAL

Patio Covers / Carports

Uncovered Decks & Porches

SPECIFICATION Section Insulated Precast Concrete Wall Panels

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions

TechPractices: Home Front Homes:

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

COMMERCIAL BUILDINGS. Quality Buildings Since 1983

BURNISHED SLATE COVER PHOTO: SLATE GREY

SECTION PRECAST CONCRETE STRUCTURES

SECTION FREIGHT & PARKING GARAGE ELEVATORS PART I - GENERAL

IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality

NAPCA BULLETIN APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL

The minimum reinforcement for the stem wall is the placement of:

INSTALLATION. General. Important Note. Design. Transport

Residential Deck Safety, Construction, and Repair

How To Design A Post Tensioned Deck For A Building

Springlok Flashing System

Coastal Metal Service

Transcription:

DENVER MODEL 30 X 30 SPECIFICATIONS Dimensions: Roof Dimensions 30-0 x 30-0 (4) Columns (Center to Center) 25-6½ x 25-6½ Minimum Clearance 8-0 Roof Height @ Peak Dependent on Col. Ht. Hip Roof 4:12 pitch Square Feet Under Roof 900 Short steel columns shall be 7 x 7 square tube, minimum.188 wall thickness connecting to the top of the masonry columns with an embed plate. All beams shall be structural steel tube sized according to engineering. Embed plates shall be grouted into the column tops and shall be included with the structure. Masonry columns shall be provided by others. All bolts shall be A-325 or A-307 and hidden at all connections. Roofing shall be 24 gauge 12 OC Standing Seam steel roof with ribs running with the slope of the roof. Trim shall be 24 gauge to match roofing. Fascia shall be tube steel. Open or welded C channel, I beams, S or Z purlins or angle iron shall not be allowed. 11875 E. Berry Dr.- Dewey, AZ 86327 Ph: (928) 775-3307 Fax: (928) 772-0858 info@classicrecreation.com www.classicrecreation.com

STANDARD SPECIFICATIONS 12 O.C. STANDING SEAM ROOF w/ ZINC RICH PRIMER & TGIC POLYESTER POWDER COAT GENERAL: 1. All structures shall be designed and fabricated to the IBC (or latest edition applicable code) with standard load designs of 20# per S.F. live load, 100 mph minimum wind load and the applicable zone for seismic loads. 2. All members shall be designed according to the American Institute of Steel Construction (AISC) specifications and the American Iron and Steel Institute (AISI) specifications for cold-formed members. 3. All fabrication welds shall be in strict accordance with the structural welding code of the American Welding Society (AWS) specifications. All structural welds shall be in compliance with the requirements of Pre-qualified welded joints. All welding shall conform to series E-70XX metal core wire with Star 66 gas mix. Field welding shall not be required. 4. When required, after award of bid, the shade structure manufacturer shall submit structural calculations, sealed by a registered engineer in the state in which the structure is to be erected for review and approval by the approving agency. 5. Manufacturer qualifications: All manufacturers shall have a minimum of 5 years experience in the fabrication of tubular steel shade structures. Shade structure and kiosk fabrication shall be the manufacturer s primary business. Manufacturer shall have fabricated similar structures to that which is specified. All non-specified manufacturers shall submit complete shop drawings indicating type, size & gauge of material used, with detailed connections to the specifying agency or design firm at least 10 days prior to bid opening for review and written pre-approval. All bids submitted without prior approval will be rejected. FOOTINGS & COLUMNS: 1. Footings shall be structurally engineered by the structure manufacturer to meet local codes and site conditions. (Sample footing drawings shall be made available to the contractor or owner from the manufacturer). Anchor bolts for surface mounted structures shall be supplied by the owner / contractor. Columns shall be ASTM 500 grade B. Concrete footing rebar (if required) shall be ASTM A-615 grade 40 #4 bars & smaller, grade 60 #5 bars & larger. Concrete shall be 5 sack mix Portland cement. Maximum slump shall not exceed 4. Compressive strength: 2500 psi @ 28 days. FRAME MEMBERS AND COMPRESSION RING: 1. All frame members shall be one piece structural steel tube with a minimum.120 (1/8 ) wall thickness, sized according to engineering. All frame members shall be bolted together with bolts totally concealed. Compression rings shall be fabricated from structural steel tube or flat plate steel and shall have all connections concealed from view. All tubing for frame members shall be ASTM 500 grade B. Beam end plates

shall be ASTM A36 fy=36,000 psi UNO. Bolts shall be A 307 s, or 325 s unless noted otherwise. I beams, Angle iron, C, Z or S purlins or beams, open or closed, shall not be allowed. ROOFING AND TRIM: 1. All roofing shall be 24 gauge Zincalume / Galvalume coated steel panels. Standing Seam panels shall be Design Span by AEP Span or McElroy with 1¾ high ribs @ 12 o.c. All roofing shall be pre-finished with Duratech 5000 or equal, 30 year paint finish. All roof panels shall be pre-cut with ribs running with the slope of the roof. Fascia shall be tube steel. Trim shall be 24 gauge Zincalume / Galvalume coated pre-finished to match the roof color. Screws & rivets shall match roof color. PAINT: 1. All frame members shall be media blasted to a white finish removing all rust, scale, oil and grease. Powder coat all frame members with zinc rich primer and TGIC polyester, min. 4-5 mil finish. Finish shall be a smooth uniform surface with no pits, runs or sags. ERECTION: 1. Manufacturer shall supply complete layout and detail plans with installation instructions for the structure. The structure shall be erected in a work-man-like manner with framing, roofing and trim installed according to the manufacturers installation instructions. Care shall be taken to avoid damaging the structure during installation. WARRANTEE: 1. Manufacturer shall warranty the structure to be free from defects in material and workman-ship for a period of (5) five years from date of acceptance by owner. Warranty does not include damage from theft, fire, vandalism or acts of God. Manufacturer shall repair or replace structure components of like kind at his option, to match existing material and workmanship. NOTE: Engineering specifications take precedence over drawings if differences occur.