Configuration Examples for FAS2240 Systems

Similar documents
Storage Efficiency Express Guide For 7-Mode Administrators Learning Cluster-Mode

NetApp FAS/V-Series Storage Replication Adapter for Clustered Data ONTAP

SnapManager 8 for Microsoft SharePoint Disaster Recovery User s Guide

NetApp Storage Array Management Pack for Operations Manager 2.1

Clustered Data ONTAP 8.3

Hot-swapping a power supply

NetApp E-Series Plug-in for Microsoft SQL Server Management Studio Installation Guide

Software Storage Platform Mixing Rules

Cloud ONTAP 8.3 for Amazon Web Services

SnapManager 8.1 for Microsoft SharePoint Job Monitor User s Guide

Logical Replication (LREP) Tool User Guide

Navigating VSC 6.0 for VMware vsphere

SGI InfiniteStorage 4000 Series and 5000 Series Concepts Guide for SANtricity ES Storage (ISSM 10.86)

Clustered Data ONTAP 8.3

V-Series Systems Implementation Guide for EMC CLARiiON Storage

Clustered Data ONTAP 8.3

Data ONTAP DSM for Windows MPIO Release Notes

Fibre Channel and iscsi Configuration Guide

NetApp E-Series Storage Systems Concepts for SANtricity ES Storage Manager Version 10.86

SnapDrive for UNIX Quick Start Guide (IBM AIX, HP-UX, Linux, Solaris )

Single Mailbox Recovery 6.1 ExtractWizard Release Notes

NetApp E-Series Storage Systems Concepts for SANtricity ES Storage Manager Version 10.86

NetApp SANtricity Add-in for Microsoft SQL Server Management Studio 1.3

Clustered Data ONTAP 8.2

NetApp E-Series Storage Systems. Command Line Interface and Script Commands for Version 10.84

Config Advisor 3.2. Installation and Administration Guide

Replacing the chassis on a FAS20xx system

NetApp E-Series Storage Systems Initial Configuration and Software Installation. For SANtricity ES Storage Manager 10.86

SnapManager 5.0 for Microsoft Exchange Installation and Administration Guide

SGI InfiniteStorage 4000 Series and 5000 Series Configuring and Maintaining a Storage Array (ISSM 10.86)

How To Manage A System On A Pc Or Mac Or Mac (Or Mac) With A Hard Drive Or Ipnet (Or Ipnet) On A Computer Or Mac) On Your Computer Or Computer (Or Pc Or Pc Or Ipro) On

SnapManager for Microsoft SharePoint Server Release Notes

Data ONTAP 7.3 System Administration Guide

Open Systems SnapVault Installation and Administration Guide

SGI InfiniteStorage 4000 Series and 5000 Series Configuring and Maintaining a Storage Array Using the Command Line Interface (ISSM 10.

Data ONTAP 7.3 Data Protection Online Backup and Recovery Guide

Configuration Rules and Examples for FAS20xx Systems

OnCommand System Manager 3.1

Data ONTAP 7.3 Storage Management Guide

Data ONTAP 7.3 Storage Efficiency Management Guide

Clustered Data ONTAP 8.3

Datasheet NetApp FAS8000 Series

Clustered Data ONTAP 8.3

Introducing NetApp FAS2500 series. Marek Stopka Senior System Engineer ALEF Distribution CZ s.r.o.

High Availability and MetroCluster Configuration Guide For 7-Mode

Clustered Data ONTAP 8.2

Pricing - overview of available configurations

Datasheet The New NetApp FAS3200 Series Enables Flash, Clustering to Improve IT Agility and Performance

Data ONTAP Mode NCDA NSO-154 Certification Study Guide

NetApp AFF8080 EX Performance and Server Consolidation with Microsoft SQL Server 2014

Cisco, Citrix, Microsoft, and NetApp Deliver Simplified High-Performance Infrastructure for Virtual Desktops

Entry level solutions: - FAS 22x0 series - Ontap Edge. Christophe Danjou Technical Partner Manager

Datasheet NetApp FAS6200 Series

Data ONTAP 7.3 File Access and Protocols Management Guide

At A Glance. Guide To NetApp Certification

NetApp Training and Certification 2009

System Manager 1.1. Customer Presentation Feb 2010

NetApp FAS2000 Series

OnCommand Insight 7.2. Installation Guide. For Red Hat Enterprise Linux. April _B0

Setting up CIFS shares and joining the Active Directory. Why join an N series storage system to Active Directory?

Fibre Channel and iscsi Configuration Guide

vcenter Management Plug-in for NetApp E-Series Storage, Version 2.4 User Guide

Installing the 16-port Cisco unified port expansion module in Nexus 5596 cluster switches

Reducing the cost of Protecting and. Securing Data. Assets. Big data, small data, critical data, more data. NetApp

FlexArray Virtualization

How To Write A Server On A Flash Memory On A Perforce Server

Datasheet NetApp FAS3200 Series

Clustered Data ONTAP 8.3 Administration and Data Protection Training

NetApp FAS3200 Series

Clustered Data ONTAP 8.3

New Cluster-Ready FAS3200 Models

an introduction to networked storage

OnCommand Unified Manager

IBM System Storage N3400 offers enterprise-class Fibre Channel, iscsi, SAS, and NAS storage

Introduction to NetApp Infinite Volume

NetApp FAS/V-Series. NetApp BDM

NetApp OnCommand Shift 1.0

SnapManager 8.2 for Microsoft SharePoint

OnCommand Report 1.2. OnCommand Report User Guide. NetApp, Inc. 495 East Java Drive Sunnyvale, CA U.S.

ENABLING RHEV WITH NETAPP STORAGE. Jon Benedict Systems Architect, NetApp Geert Jansen RHEV Product Marketing Manager, Red Hat May 6, 2011

Network Appliance, Inc.

The IBM Storage System N series

Integrating Mac OS and NetApp Storage

FAQ. NetApp MAT4Shift. March 2015

Advanced Data Mobility To Power Your Hybrid Cloud

IBM System Storage. N3300 Installation and Setup Instructions

My AutoSupport. User Guide. October 2013

Disaster Recovery Procedures for Microsoft SQL 2000 and 2005 using N series

SnapManager for Oracle 2.2. Anand Ranganathan Product & Partner Engineer (PPE)

Constant Replicator: An Introduction

Open Source Used In Cisco Instant Connect for ios Devices 4.9(1)

Transcription:

Configuration Examples for FAS2240 Systems NetApp, c. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1(408) 822-6000 Fax: +1(408) 822-4501 Support telephone: +1 (888) 463-8277 Web: www.netapp.com Feedback: doccomments@netapp.com Part number: 215-07051_B0 June 2013

Table of Contents 3 Contents FAS2240 configuration options... 4 Required configuration for FAS2240 systems running clustered Data ONTAP... 6 Example 1: HA pair with no external disk shelves... 9 Example 2: HA pair with external SAS shelves... 10 Example 3: HA pair with SAS tape backup... 12 Example 4: HA pair with external SAS shelves and tape backup... 13 Example 5: Stand-alone controller with SAS shelves (single-path)... 15 Example 6: Stand-alone controller with SAS shelves (dual-path)... 17 Example 7: Stand-alone controller with SAS shelves (single-path) and tape backup... 19 Example 8: HA pair connected to an FC SAN... 21 Example 9: HA pair connected to an FC SAN with FC tape backup... 23 Example 10: HA pair with FC shelves and FC tape backup... 25 Example 11: HA pair connected to an FC SAN and with FC disk shelves... 27 Example 12: HA pair with FC disk shelves... 29 Example 13: Stand-alone controller connected to an FC SAN... 31 Example 14: Stand-alone controller with FC disk shelves and FC tape backup... 32 Example 15: Stand-alone controller connected to an FC SAN with FC disk shelves... 34 Example 16: Stand-alone controller with FC disk shelves... 36 Copyright information... 37 Trademark information... 38 How to send your comments... 39 dex... 40

4 Configuration Examples for FAS2240 Systems FAS2240 configuration options The FAS2240 systems can be used in a variety of physical configurations and with different storage protocols. Configuration Possible variations Storage protocol NFS, CIFS, and/or iscsi FC SAN, using the FC mezzanine card Mezzanine card None This system can be configured without a mezzanine card. this case, a blank with no ports takes the place of the mezzanine card in the controller module. Dual-port 10-Gb Ethernet option Dual-port 8/4/2 Gb FC option The FC ports can attach to disk shelf and backup device connections, or to a SAN using the FC protocol. See the SAN Configuration Guide (called Fibre Channel and iscsi Configuration Guide in Data ONTAP 8.1 and earlier) on the NetApp Support Site at support.netapp.com for more information. Controller resiliency HA pair The system has two redundant controller modules. Stand-alone configuration The system has one controller module. ternal/external storage ternal disks ternal disks in the system chassis are used. External disks or tape: SAS The onboard SAS ports can attach to disk shelves or backup devices. For SAS configuration rules, see the Universal SAS and ACP Cabling Guide. FC The optional FC mezzanine card supports FC connectivity to an FC SAN or FC storage devices.

FAS2240 configuration options 5 Configuration Disk shelf connection redundancy Backup device Possible variations Multipath configuration The controller has multiple connections to disks on the disk shelves. Multipath is the preferred configuration. Dual-path configuration The controller has two connections to disks on the disk shelves. Single-path configuration The disk shelves have a single connection to the controller. This configuration is not preferred but is supported on entry-level platforms. External backup devices The system connects to a tape backup device.

6 Configuration Examples for FAS2240 Systems Required configuration for FAS2240 systems running clustered Data ONTAP The FAS2240 systems support clustered Data ONTAP. This requires the 10-GbE mezzanine card to provide the connections to the cluster network unless you are operating a single-node cluster. Switched-cluster configuration The following example shows a FAS2240 system configured to support clustered Data ONTAP: Note: This example shows a FAS2240-4 system, which has its controller modules arranged vertically, with one above the other. A FAS2240-2 system's controller modules are arranged side by side in the chassis. The cabling is the same, regardless of the model or the position of the controller modules. This configuration has the following requirements and options: The 10-GbE mezzanine card is required in each controller module. All four 10-GbE ports (the e1a and e1b ports on both controllers) are required for cluster-network connections. Either two or four of the onboard GbE ports are used for the data network connections. The Remote Management port (marked with a wrench icon) is used for the management network connections. This port also allows access to the Service Processor.

Required configuration for FAS2240 systems running clustered Data ONTAP 7 This configuration supports NFS, CIFS, and iscsi protocols as shown in other configuration examples. This configuration can be used with SAS storage only. Two-node switchless-cluster configuration The following examples show a FAS2240 system configured to support clustered Data ONTAP with either redundant back-to-back cluster connections or a single-cluster connection. This configuration is referred to as a two-node switchless cluster. The redundant configuration is recommended. Redundant cluster connections Single, non-redundant cluster connection Note: This example shows a FAS2240-4 system, which has its controller modules arranged vertically, with one above the other. A FAS2240-2 system's controller modules are arranged side by side in the chassis. The cabling is the same, regardless of the model or the position of the controller modules. This configuration has the following requirements and options: The 10-GbE mezzanine card is required in each controller module. All four 10-GbE ports (the e1a and e1b ports on both controllers) are required for fully redundant cluster connections. The cluster ports are directly connected without a switch. Note: A configuration using a single 10-GbE port on each controller is supported to allow use of the e1b ports for data, but this does not provide a redundant connection in the event of a cable or port failure. Two or four of the onboard GbE ports are used for the data network connections. The Remote Management port (marked with a wrench icon) is used for the management network connections.

8 Configuration Examples for FAS2240 Systems This port also allows access to the Service Processor. This configuration supports NFS, CIFS, and iscsi protocols as shown in other configuration examples. This configuration can be used with SAS storage only. Single-node cluster configuration The following example shows a single FAS2240 node configured to support clustered Data ONTAP. This configuration has the following requirements and options: Either of the available mezzanine cards can optionally be used with this configuration. Because this is a single-node configuration, the 10-GbE mezzanine card ports can be used for data connections. The FC mezzanine card can be used for storage or host connections as shown in other configuration examples. Either two or four of the onboard GbE ports are used for the data network connections. The Remote Management port (marked with a wrench icon) is used for the management network connections. This port also allows access to the Service Processor. This configuration supports NFS, CIFS, iscsi, and FC protocols as shown in other configuration examples.

9 Example 1: HA pair with no external disk shelves The FAS2240 systems can be configured as an HA pair with no external disk drives. e e The red cables are Ethernet ACP connections. The blue cables are SAS disk shelf connections. Note: This example shows a FAS2240-4 system, which has its controller modules arranged vertically, with one above the other. A FAS2240-2 system's controller modules are arranged side by side in the chassis. The cabling is the same, regardless of the model or the position of the controller modules. Configuration details Storage protocol Mezzanine card Controller resiliency ternal/external storage Disk shelf connection redundancy Backup device Configuration used NFS, CIFS, FC, and/or iscsi None HA pair ternal only Multipath HA Note: This is the recommended configuration. If the external cables are not used, the internal drives have single-path connectivity. Such a configuration is supported but not recommended. None

10 Configuration Examples for FAS2240 Systems Example 2: HA pair with external SAS shelves The FAS2240 systems can be configured as an HA pair with external SAS disk shelves. e e IOM A IOM B IOM A IOM B IOM A IOM B The red cables are Ethernet ACP connections. The blue cables are SAS disk shelf connections. Note: This example shows a FAS2240-4 system, which has its controller modules arranged vertically, with one above the other. A FAS2240-2 system's controller modules are arranged side by side in the chassis. The cabling is the same, regardless of the model or the position of the controller modules.

Example 2: HA pair with external SAS shelves 11 Configuration details Storage protocol Mezzanine card Controller resiliency External storage Disk shelf connection redundancy Backup device Configuration used NFS, CIFS, FC, iscsi None HA pair External SAS disk shelves Multipath HA None If you have SSD shelves If you have SAS disk shelves with SSDs, the shelves with the SSDs should be the last shelves in the stack and connect to the port on each controller. This allows the SSD drives to have the shortest possible SAS path to the controller.

12 Configuration Examples for FAS2240 Systems Example 3: HA pair with SAS tape backup The FAS2240 systems can be configured as an HA pair with an external SAS tape backup device. e e SAS Tape Backup Device The red cables are Ethernet ACP connections. The black cables are SAS tape drive connections. Note: This example shows a FAS2240-4 system, which has its controller modules arranged vertically, with one above the other. A FAS2240-2 system's controller modules are arranged side by side in the chassis. The cabling is the same, regardless of the model or the position of the controller modules. Configuration details Storage protocol Mezzanine card Controller resiliency External storage Disk shelf connection redundancy Backup device Configuration used NFS, CIFS, FC, and/or iscsi None HA pair ternal only n/a SAS tape backup device

13 Example 4: HA pair with external SAS shelves and tape backup The FAS2240 systems can be configured as an HA pair connected to external SAS disk shelves and a SAS tape backup device. SAS Tape Backup Device e e IOM A IOM B IOM A IOM B IOM A IOM B

14 Configuration Examples for FAS2240 Systems The red cables are Ethernet ACP connections. The blue cables are SAS disk shelf connections. The black cables are SAS tape drive connections. Note: This example shows a FAS2240-4 system, which has its controller modules arranged vertically, with one above the other. A FAS2240-2 system's controller modules are arranged side by side in the chassis. The cabling is the same, regardless of the model or the position of the controller modules. Configuration details Storage protocol Mezzanine card Controller resiliency External storage Disk shelf connection redundancy Backup device Configuration used NFS, CIFS, FC, iscsi None HA pair External SAS Single-path Single-path SAS tape backup device

15 Example 5: Stand-alone controller with SAS shelves (single-path) The FAS2240 systems can be configured as stand-alone controllers with an external stack of SAS disk shelves, with single-path connectivity. Although the single-path connections provide less resiliency than a dual-path configuration, Data ONTAP does not display the intermittent alert messages that appear when a dual-path configuration is used. Note: This configuration is not recommended for shelves with SSDs. e IOM A IOM B IOM A IOM B IOM A IOM B The red cables are Ethernet ACP connections. The blue cables are SAS disk shelf connections.

16 Configuration Examples for FAS2240 Systems Configuration details Storage protocol Mezzanine card Controller resiliency External storage Disk shelf connection redundancy Backup device Configuration used NFS, CIFS, FC, iscsi None Stand-alone External SAS disk shelves Single-path None

17 Example 6: Stand-alone controller with SAS shelves (dual-path) The FAS2240 system can be configured as a stand-alone controller with dual-path connectivity to external SAS storage. This configuration provides more resiliency than the single-path configuration, but Data ONTAP displays intermittent alert messages that the system is in a mixed-path configuration. Note: The dual-path configuration is not recommended for shelves with SSDs. However, if you have SAS disk shelves with SSDs, the shelves with the SSDs should be the last shelves in the stack and connect to the port on each controller. This allows the SSD drives to have the shortest possible SAS path to the controller. e IOM A IOM B IOM A IOM B IOM A IOM B The red cables are Ethernet ACP connections.

18 Configuration Examples for FAS2240 Systems The blue cables are SAS disk shelf connections. Configuration details Storage protocol Mezzanine card Controller resiliency External storage Disk shelf connection redundancy Backup device Configuration used NFS, CIFS, FC, iscsi None Stand-alone External SAS disk shelves Dual-path None

19 Example 7: Stand-alone controller with SAS shelves (single-path) and tape backup The FAS2240 system can be configured as a stand-alone controller with single-path connections to a stack of SAS disk shelves and a SAS tape backup device. SAS Tape Backup Device e IOM A IOM B IOM A IOM B IOM A IOM B The red cables are Ethernet ACP connections.

20 Configuration Examples for FAS2240 Systems The blue cables are SAS disk shelf connections. The black cables are SAS tape drive connections. Configuration details Storage protocol Mezzanine card Controller resiliency External storage Disk shelf connection redundancy Backup device Configuration used NFS, CIFS, FC, iscsi None Stand-alone External SAS disk shelves Single-path SAS tape backup device

21 Example 8: HA pair connected to an FC SAN The FAS2240 system can be configured as an HA pair connected to a SAN network. SAS disk shelves or tape storage devices can optionally be attached to the onboard SAS ports as shown in other examples. FC SAN e 1a 1b e 1a 1b The black cables are connections to the FC SAN. Note: This example shows a FAS2240-4 system, which has its controller modules arranged vertically, with one above the other. A FAS2240-2 system's controller modules are arranged side by side in the chassis. The cabling is the same, regardless of the model or the position of the controller modules. Configuration details Storage protocol Mezzanine card Controller resiliency External storage Configuration used NFS, CIFS, FC, and/or iscsi FC HA pair None shown, but this configuration can be used with SAS disk shelves or backup devices attached to the onboard SAS ports, as shown in Examples 2, 3, and 4.

22 Configuration Examples for FAS2240 Systems Configuration details Disk shelf or host connection redundancy Backup device Configuration used Dual-path None

23 Example 9: HA pair connected to an FC SAN with FC tape backup The FAS2240 system can be connected to a SAN network and an FC tape device. FC SAN e 1a 1b e 1a 1b FC tape backup device The black cables are connections to the FC SAN and the FC tape device. Note: This example shows a FAS2240-4 system, which has its controller modules arranged vertically, with one above the other. A FAS2240-2 system's controller modules are arranged side by side in the chassis. The cabling is the same, regardless of the model or the position of the controller modules. Configuration details Storage protocol Mezzanine card Configuration used NFS, CIFS, FC, and/or iscsi FC

24 Configuration Examples for FAS2240 Systems Configuration details Controller resiliency External storage Disk shelf and host connection redundancy Backup device Configuration used HA pair None Single-path FC tape backup device

25 Example 10: HA pair with FC shelves and FC tape backup The FAS2240 system can be connected to an FC disk shelf loop and an FC tape device. FC tape backup device e 1a 1b e 1a 1b DS14mk2/mk4 DS14mk2/mk4 DS14mk2/mk4 The blue cables are FC disk shelf connections.

26 Configuration Examples for FAS2240 Systems The black cables are FC SAN connections. Note: This example shows a FAS2240-4 system, which has its controller modules arranged vertically, with one above the other. A FAS2240-2 system's controller modules are arranged side by side in the chassis. The cabling is the same, regardless of the model or the position of the controller modules. Configuration details Storage protocol Mezzanine card Controller resiliency External storage Disk shelf connection redundancy Backup device Configuration used NFS, CIFS, and/or iscsi FC HA pair External FC disk shelves Dual-path FC tape backup device

27 Example 11: HA pair connected to an FC SAN and with FC disk shelves The FAS2240 system can be connected to an FC SAN and an FC disk shelf loop. FC SAN e 1a 1b e 1a 1b DS14mk2/mk4 DS14mk2/mk4 DS14mk2/mk4 The blue cables are FC disk shelf connections.

28 Configuration Examples for FAS2240 Systems The black cables are FC SAN connections. Note: This example shows a FAS2240-4 system, which has its controller modules arranged vertically, with one above the other. A FAS2240-2 system's controller modules are arranged side by side in the chassis. The cabling is the same, regardless of the model or the position of the controller modules. Configuration details Storage protocol Mezzanine card Controller resiliency External storage Disk shelf connection redundancy Backup device Configuration used NFS, CIFS, FC, and/or iscsi FC HA pair External FC disk shelves Dual-path None

29 Example 12: HA pair with FC disk shelves The FAS2240 system can be connected to an FC disk shelf loop. e 1a 1b e 1a 1b DS14mk2/mk4 DS14mk2/mk4 DS14mk2/mk4 The blue cables are FC disk shelf connections. The blue dashed cables are FC disk shelf multipath HA connections. Note: This example shows a FAS2240-4 system, which has its controller modules arranged vertically, with one above the other. A FAS2240-2 system's controller modules are arranged side by side in the chassis. The cabling is the same, regardless of the model or the position of the controller modules.

30 Configuration Examples for FAS2240 Systems Configuration details Storage protocol Mezzanine card Controller resiliency External storage Disk shelf connection redundancy Backup device Configuration used NFS, CIFS, and/or iscsi FC HA pair External FC disk shelves Multipath HA None

31 Example 13: Stand-alone controller connected to an FC SAN The FAS2240 system with a stand-alone controller can be connected an FC SAN. FC SAN e 1a 1b The black cables are connections to the FC SAN. Configuration details Storage protocol Mezzanine card Controller resiliency External storage Disk shelf connection redundancy Backup device Configuration used FC SAN FC Stand-alone controller ternal only n/a None

32 Configuration Examples for FAS2240 Systems Example 14: Stand-alone controller with FC disk shelves and FC tape backup The FAS2240 system with a stand-alone controller can be connected to FC disk shelves and to an FC tape backup device. FC tape backup device e 1a 1b DS14mk2/mk4 DS14mk2/mk4 DS14mk2/mk4 The blue cables are FC disk shelf connections. The black cables are FC tape drive connections.

Example 14: Stand-alone controller with FC disk shelves and FC tape backup 33 Configuration details Storage protocol Mezzanine card Controller resiliency External storage Disk shelf connection redundancy Backup device Configuration used FC SAN FC Stand-alone controller ternal only Single-path FC tape

34 Configuration Examples for FAS2240 Systems Example 15: Stand-alone controller connected to an FC SAN with FC disk shelves The FAS2240 system with a stand-alone controller can be connected to an FC SAN and FC disk shelves. FC SAN e 1a 1b DS14mk2/mk4 DS14mk2/mk4 DS14mk2/mk4 The blue cables are FC disk shelf connections. The black cables connect to the FC SAN.

Example 15: Stand-alone controller connected to an FC SAN with FC disk shelves 35 Configuration details Storage protocol Mezzanine card Controller resiliency External storage Disk shelf and host connection redundancy Backup device Configuration used FC SAN FC Stand-alone controller External FC disk shelves Single path None

36 Configuration Examples for FAS2240 Systems Example 16: Stand-alone controller with FC disk shelves The FAS2240 system with a stand-alone controller can be connected to FC disk shelves. e 1a 1b DS14mk2/mk4 DS14mk2/mk4 DS14mk2/mk4 The blue cables are FC disk shelf connections. Configuration details Storage protocol Mezzanine card Controller resiliency External storage Disk shelf connection redundancy Backup device Configuration used NFS, CIFS, and/or iscsi FC Stand-alone controller FC disk shelves Dual-path None

37 Copyright information Copyright 1994 2013 NetApp, c. All rights reserved. Printed in the U.S. No part of this document covered by copyright may be reproduced in any form or by any means graphic, electronic, or mechanical, including photocopying, recording, taping, or storage in an electronic retrieval system without prior written permission of the copyright owner. Software derived from copyrighted NetApp material is subject to the following license and disclaimer: THIS SOFTWARE IS PROVIDED BY NETAPP "AS IS" AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY DISCLAIMED. IN NO EVENT SHALL NETAPP BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. NetApp reserves the right to change any products described herein at any time, and without notice. NetApp assumes no responsibility or liability arising from the use of products described herein, except as expressly agreed to in writing by NetApp. The use or purchase of this product does not convey a license under any patent rights, trademark rights, or any other intellectual property rights of NetApp. The product described in this manual may be protected by one or more U.S. patents, foreign patents, or pending applications. RESTRICTED RIGHTS LEGEND: Use, duplication, or disclosure by the government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.277-7103 (October 1988) and FAR 52-227-19 (June 1987).

38 Configuration Examples for FAS2240 Systems Trademark information NetApp, the NetApp logo, Network Appliance, the Network Appliance logo, Akorri, ApplianceWatch, ASUP, AutoSupport, BalancePoint, BalancePoint Predictor, Bycast, Campaign Express, ComplianceClock, Cryptainer, CryptoShred, CyberSnap, Data Center Fitness, Data ONTAP, DataFabric, DataFort, Decru, Decru DataFort, DenseStak, Engenio, Engenio logo, E-Stack, ExpressPod, FAServer, FastStak, FilerView, Flash Accel, Flash Cache, Flash Pool, FlashRay, FlexCache, FlexClone, FlexPod, FlexScale, FlexShare, FlexSuite, FlexVol, FPolicy, GetSuccessful, gfiler, Go further, faster, Imagine Virtually Anything, Lifetime Key Management, LockVault, Mars, Manage ONTAP, MetroCluster, MultiStore, NearStore, NetCache, NOW (NetApp on the Web), Onaro, OnCommand, ONTAPI, OpenKey, PerformanceStak, RAID-DP, ReplicatorX, SANscreen, SANshare, SANtricity, SecureAdmin, SecureShare, Select, Service Builder, Shadow Tape, Simplicity, Simulate ONTAP, SnapCopy, Snap Creator, SnapDirector, SnapDrive, SnapFilter, Snaptegrator, SnapLock, SnapManager, SnapMigrator, SnapMirror, SnapMover, SnapProtect, SnapRestore, Snapshot, SnapSuite, SnapValidator, SnapVault, StorageGRID, StoreVault, the StoreVault logo, SyncMirror, Tech OnTap, The evolution of storage, Topio, VelocityStak, vfiler, VFM, Virtual File Manager, VPolicy, WAFL, Web Filer, and XBB are trademarks or registered trademarks of NetApp, c. in the United States, other countries, or both. IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of ternational Business Machines Corporation in the United States, other countries, or both. A complete and current list of other IBM trademarks is available on the web at www.ibm.com/legal/copytrade.shtml. Apple is a registered trademark and QuickTime is a trademark of Apple, c. in the United States and/or other countries. Microsoft is a registered trademark and Windows Media is a trademark of Microsoft Corporation in the United States and/or other countries. RealAudio, RealNetworks, RealPlayer, RealSystem, RealText, and RealVideo are registered trademarks and RealMedia, RealProxy, and SureStream are trademarks of RealNetworks, c. in the United States and/or other countries. All other brands or products are trademarks or registered trademarks of their respective holders and should be treated as such. NetApp, c. is a licensee of the CompactFlash and CF Logo trademarks. NetApp, c. NetCache is certified RealSystem compatible.

39 How to send your comments You can help us to improve the quality of our documentation by sending us your feedback. Your feedback is important in helping us to provide the most accurate and high-quality information. If you have suggestions for improving this document, send us your comments by email to doccomments@netapp.com. To help us direct your comments to the correct division, include in the subject line the product name, version, and operating system. You can also contact us in the following ways: NetApp, c., 495 East Java Drive, Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277

40 Configuration Examples for FAS2240 Systems dex F FAS2240 hardware configuration options 4 FAS2240 configuration for clustered Data ONTAP 6