Atlas Event Logging Explanation



Similar documents
Chapter 4 T1 Interface Card

For T1 / E1, an NT NeTwork device must be connected to a TE Terminal Equipment device; NT must connect to TE.

LifeSize Networker Installation Guide

RADview/TDM. Element Management System for TDM Applications Optimux-T RAD Data Communications Publication 06/05

Mediatrix 4404 Step by Step Configuration Guide June 22, 2011

SNMP Network Node Manager (NNM) Setup Guide

Installation and setup guide V 1.0

Information Note Connecting a BRI - checklist

Deployment Guide for Maximum Security Environments Polycom HDX Systems, Version 3.0.5

F453. TiF453. User guide 10/11-01 PC

T3 Module USER MANUAL. Part Number L1 / L1

How To Configure An African Atlas

Trinity Feature: T1/E1 Configuration

Configuring the ADTRAN ATLAS for a Rabbit-Hole Application

T3 Mux M13 Multiplexer

Configuration Notes 283

ISDN Diagnostic Codes

LifeSize Gateway User Guide

BRI to PRI Connection Using Data Over Voice

Troubleshooting for Yamaha router

HighPoint RAID Management User s Guide

Figure 1 - T1/E1 Internet Access

elprolog MONITOR Operation Manual

ECcom. Signal Monitor Communications Software Operations Manual

Date Rev. Details Author

Vega 100G and Vega 200G Gamma Config Guide

Network Management System and ICB Management System Software for T1 User s Guide

Product Guide CM-Relay

Network Management System and ICB Management System Software User s Guide

FrontDesk Installation And Configuration

Configuring E1 and T1 Interfaces

TX3 Series TELEPHONE ACCESS SYSTEMS. Configurator Quick Start. Version 2.2 Mircom Copyright 2014 LT-973

Configuring E1 and T1 Interfaces

Loop-V4300 MINI DACS E1/ T1 CONVERTER

Type Message Description Probable Cause Suggested Action. Fan in the system is not functioning or room temperature

Technical Overview CM-16 Climate Monitor. Get yours direct at:

WRE2205. User s Guide. Quick Start Guide. Wireless N300 Range Extender. Default Login Details. Version 1.00 Edition 1, 06/2012

Chapter 4 Managing Your Network

Benefits Of Upgrading To The Latest CIX Processor

Authenticating a Lucent Portmaster 3 with Microsoft IAS and Active Directory

Link Gate SIP. (Firmware version 1.20)

Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation

Norstar/Companion Alarm & Event Code Manual

Troubleshooting Tools to Diagnose or Report a Problem February 23, 2012

Quick Start Guide. Vpacket 5100/6100 Voice/Data Router SIP with PRI/ISDN Procedure Release 2.1.1

Release Notes for SIP Enablement Services Release Service Pack 2

PBX DIGITAL TELEPHONE EXCHANGE MAINTENANCE GUIDE

VOICE RECORDING SYSTEM ISDN PRI / BRI

Before You Start 1 Overview 2 Supported Devices 4 Public (User LAN) and Private (APC LAN) Networks 5. Initial Configuration Requirements 6

BroadCloud Adtran Total Access Quick Start Guide

4. H.323 Components. VOIP, Version 1.6e T.O.P. BusinessInteractive GmbH Page 1 of 19

Technical Overview CM-2 Climate Monitor. Get yours direct at:

DDM Distributed Database Manager for SQL and ODBC. Installation and User Guide Version 5.27.xx

One Port Serial Server Users Manual Model ESP901, ESP901E

VoIP Services User Guide

5100 Spreader Control Event Logging Installation, Calibration and Operation Manual

Remote Supervisor Adapter II. User s Guide

CAMPUS-RS CSU/DS-1 INTERFACE CARDS

A More Secure and Cost-Effective Replacement for Modems

Optimum Business SIP Trunk Set-up Guide

Chapter 9 Monitoring System Performance

DRO-210i LOAD BALANCING ROUTER. Review Package Contents

Title Page Web/SNMP Management SmartSlot Card

CipherLab 5100 Time Attendance Utility Manual

Calrec SoundGrid I/O. User Guide

MAGIC TH6. System Configuration SW Version 2.000

Troubleshooting Remote Viewing on the. Combo DVR/Monitor System

AT-S99 and AT-S102 Version Management Software for the Converteon Media Converter Products. Software Release Notes

BabyWare Imperial PC Software

Nokia E61i Configuring connection settings

Setup Reference guide

Quick Installation Guide

T3 E3 and T1 E1 Controller Commands on Cisco IOS XR Software

Linksys WAP300N. User Guide

Symantec Database Security and Audit 3100 Series Appliance. Getting Started Guide

L1-31B February NetVanta 7100 Administrator s Guide

Chapter 3 Management. Remote Management

Vehicle Monitoring Quick Reference Guide

Software User Guide UG-461

WiFi Phone WP589 User Guide

Chapter 4 Management. Viewing the Activity Log

Note: these functions are available if service provider supports them.

Chapter 6 Using Network Monitoring Tools

IP Touch 4088 EE/4018 EE SIP Phone installation manual

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

Using Advanced Phone Features

IP Phone Configuration and Troubleshooting Guide

System i and System p. Customer service, support, and troubleshooting

ADMINISTRATION GUIDE Cisco Small Business

5 Setting up a Contact Center

Troubleshooting Guide

Understanding DRAC/MC Alerts

enetworks TM Using the Syslog Feature C.1 Configuring the Syslog Feature

Debugging Network Communications. 1 Check the Network Cabling

Voice Traffic over SIP Trunks

1. Central Monitoring System Software

TestNav Common Error Codes

Transcription:

1 of 10 8/30/2006 4:35 PM Atlas Event Logging Explanation Introduction The Atlas Event Log is used to log various message types at settable threshold levels. This section describes the entries that may be logged by the system event log. The Event Log s CATEGORY is particularly important this is the minimum severity level that must be set in order that the event be logged. The Event Log is a useful tool for troubleshooting switchboard (or call connection) activities including the viewing of digits received, digits transferred, and ISDN Messages. Since most of the events viewed in the following tables are used primarily during troubleshooting, they should be turned off in normal operation. Setting the Event Log Category The following steps outline the procedure for setting up the event category thresholds for the Event Log. These settings are very useful for low level debugging as well as notification of critical system events. 1. From the main menu, go to the System Config menu and press the right-arrow key to enter the right-pane menus. The System Config menu is shown in Figure 1 below: 2. Figure 1 Select the Event Logging field and press <Enter>. Once in the Event Logging menus, press the right-arrow key to access the right-pane menus (Note: All thresholds are set to Minor by default). Figure 2 below shows the Event Logging menu:

2 of 10 8/30/2006 4:35 PM Figure 2 3. Refer to the tables under System Events below to determine the desired category thresholds. 4. To change the category, select the appropriate field and press <Enter>. This will provide a list of available options. Highlight the desired threshold and press <Enter> to select it. Whenever a system event occurs, that event will be logged if the event's severity level is equal to or more severe than the event type's current threshold setting. Figure 3 shows the available threshold options: Figure 3 Note: Use caution when changing category values from their default levels. If too many sources have their category values set too low, the number of messages being logged in a given period can be very large. If too many messages are being logged too rapidly, system performance can be adversely affected. Viewing the Events The following steps outline the procedure for viewing Event Log messages. 1. From the Main Menu, go to the System Status menu and press the right arrow key to enter the right-pane menus.

3 of 10 8/30/2006 4:35 PM Figure 4 2. Select the Event Log field and press <Enter>. Once in the Event Log, press the right arrow key to access the actual messages. Figure 5 Note: The Event Log messages are stored in a first-in/first-out table. Therefore, the most recent log entry is found at the top of the log. Note: The Event Log within the Atlas can only hold 349 entries with the oldest getting removed first. Therefore, it may be necessary to setup and external Syslog server for storage of Event Log messages. Refer to the document Using the Adtran Utility Syslog with the Atlas for more details. System Events Table 1 through Table 8 provides a listing of Atlas system events, including tables of events for each category, according to the order they appear in the Event Log setup screen. Table 1. System Controller Events CRITICAL AC Power Supply has recovered AC power supply is functioning normal again

4 of 10 8/30/2006 4:35 PM AC Power Supply has failed CRITICAL AC power supply is not operating properly AC Power Supply has Exceeded Temperature Limit CRITICAL Internal system temperature has exceeded safe operating limit AC Power Supply is Under Temperature Limit CRITICAL Internal temperature has cooled to safe operating limit DC Power Supply has recovered CRITICAL DC power supply is functioning normal again DC Power Supply has failed CRITICAL DC power supply is not operating properly DC Power Supply has Exceeded Temperature Limit CRITICAL Internal system temperature has exceeded safe operating limit DC Power Supply is Under Temperature Limit CRITICAL Internal temperature has cooled to safe operating limit Firmware invalid CRITICAL Corrupted firmware Firmware update failed CRITICAL Flash download failed System Configuration Uploaded CRITICAL Atlas configuration files loaded into the system and activated -24 V Power Failure Cleared CRITICAL -24 V power supply is functioning normally again -24 V Power Failure CRITICAL -24 V power supply is not operating properly -58 V Power Failure Cleared CRITICAL -58 V power supply is functioning normally again -58 V Power Failure CRITICAL -58 V power supply is not operating properly >70 Internal Temperature Warning Cleared CRITICAL Internal system temperature has cooled below 70 C >70C Internal Temperature Warning CRITICAL Internal system temperature is greater than 70 C >85 Internal Temperature Warning Cleared CRITICAL Internal system temperature has cooled below 85 C >85C Internal Temperature Warning CRITICAL Internal system temperature is greater than 85 C ACO Switch pressed MINOR ACO switch pressed Login Failure MINOR Console Login Failure 1 Timing source changed to Internal MINOR Neither the primary nor the backup are valid Timing source changed to Backup MINOR The primary source is invalid; backup source valid and selected Timing source changed to MINOR The timing source changed to primary Primary Not responding to MINOR Unable to program module programming External Alarm Cleared MINOR External alarm cleared External Alarm Detected MINOR Alarm detected on External Alarm Monitor Module Not Responding WARNING Module removed or not responding Cold NORMAL System cold start 2 Firmware update completed INFO Flash download successful Module Found INFO Module found SNMP Authentication Failure INFO SNMP Authentication failure 3 1 Three Consecutive logins were attempted and failed 2 Generated five seconds after the completion of system initialization

5 of 10 8/30/2006 4:35 PM 3 Generated if the Atlas receives an SNMP request from and SNMP manager defined in the Atlas SNMP communities list but with a community name that does not match the community name defined in the SNMP communities list Table 2. Switchboard Events <number> rejected: No such number WARNING Call rejected 1 <number> rejected: Outgoing reject list NORMAL Call rejected 2 <number> rejected: Busy NORMAL Call rejected 3 <number> accepted: <slot><port> NORMAL Call successfully routed 1 No such number in dial plan 2 Number is on outgoing reject list 3 All endpoints busy Table 3. Nx56/64 Events Nx56/64 Clock Slip Alarm MAJOR Clock Slip Alarm Active Active Nx56/64 Clock Slip Alarm MAJOR Clock Slip Alarm Cleared Cleared Nx56/64 External Clock MAJOR External Clock Alarm Alarm Active Nx56/64 External Clock MAJOR External Clock Alarm Cleared Alarm Cleared Nx56/64 PLL Alarm Active MAJOR PLL Alarm Active Nx56/64 PLL Alarm Cleared MAJOR PLL Alarm Cleared Nx56/64 511 Test Pattern WARNING 511 Test Pattern Activated Active Nx56/64 511 Test Pattern WARNING 511 Test Pattern Deactivated Cleared Nx56/64 Bilateral Loopback WARNING Bilateral Loopback Activated Active Nx56/64 Bilateral Loopback Cleared WARNING Bilateral Loopback Deactivated Nx56/64 Excessive Zeros WARNING Excessive Zeros from DTE Alarm Nx56/64 Excessive Zeros Alarm Cleared WARNING Excessive Zeros condition cleared Nx56/64 CTS Asserted INFO CTS Asserted Nx56/64 CTS Dropped INFO CTS Dropped Nx56/64 DCD Asserted INFO DCD Asserted Nx56/64 DCD Dropped INFO DCD Dropped Nx56/64 DTR Asserted INFO DTR Asserted Nx56/64 DTR Dropped INFO DTR Dropped Nx56/64 RTS Asserted INFO RTS Asserted Nx56/64 RTS Dropped INFO RTS Dropped Table 4. T1 Events T1 Blue Alarm Cleared MAJOR Blue Alarm Cleared T1 Blue Alarm Active MAJOR Blue Alarm Set

6 of 10 8/30/2006 4:35 PM T1 D Channel Alarm Cleared MAJOR D Channel Alarm Cleared T1 D Channel Alarm Active MAJOR D Channel Alarm Set T1 LOS Cleared MAJOR LOS Alarm Cleared T1 LOS Active MAJOR LOS Alarm Set T1 Red Alarm Cleared MAJOR Red Alarm Cleared T1 Red Alarm Active MAJOR Red Alarm Set T1 Tx Blue Alarm Cleared MAJOR Tx Blue Alarm Cleared T1 Tx Blue Alarm Active MAJOR Tx Blue Alarm Set T1 Tx Yellow Alarm Cleared MAJOR Tx Yellow Alarm Cleared T1 Tx Yellow Alarm Active MAJOR Tx Yellow Alarm Set T1 Yellow Alarm Cleared MAJOR Yellow Alarm Cleared T1 Yellow Alarm Active MAJOR Yellow Alarm Set T1 Curr CSS Thrs Exceeded WARNING Current T1 Controlled Slip Seconds T1 Curr ES Thrs Exceeded WARNING Current T1 Errored Seconds Threshold Exceeded T1 Curr LCV Thrs Exceeded WARNING Current T1 Line Code Violations T1 Curr LES Thrs Exceeded WARNING Current T1 Line Errored Seconds T1 Curr PCV Thrs Exceeded WARNING Current T1 Path Code Violations T1 Curr SEFS Thrs Exceeded WARNING Current T1 Severely Errored Framing Seconds T1 Curr SES Thrs Exceeded WARNING Current T1 Severely Errored Seconds T1 Curr UAS Thrs Exceeded WARNING Current T1 Unavailable Seconds T1 Line Loopback Active WARNING Line Loopback Active T1 Loopback Cleared WARNING Loopback Cleared T1 Payload Loopback Active WARNING Payload Loopback Active T1 Total CSS Thrs Exceeded WARNING Total T1 Controlled Slip Seconds T1 Total ES Thrs Exceeded WARNING Total T1 Errored Seconds Threshold Exceeded T1 Total LCV Thrs Exceeded WARNING Total T1 Line Code Violations T1 Total LES Thrs Exceeded WARNING Total T1 Line Errored Seconds T1 Total PCV Thrs Exceeded WARNING Total T1 Path Code Violations T1 Total SEFS Thrs Exceeded WARNING Total T1 Severely Errored Framing Seconds T1 Total SES Thrs Exceeded WARNING Total T1 Severely Errored Seconds T1 Total UAS Thrs Exceeded WARNING Total T1 Unavailable Seconds Table 5. Ethernet Events Out of Memory CRITICAL Not enough memory for Ethernet driver Table 6. ISDN Events

7 of 10 8/30/2006 4:35 PM BRI configuration failed: No ISDN CRITICAL NO BRI resources available resources are available PRI configuration failed: No ISDN CRITICAL NO PRI resources available resources are available <message>: Incorrectly MAJOR Incorrectly formatted IE formatted cause IE D channel is DOWN MAJOR D Channel Down BRI NT: SPID <spid> was MAJOR SPID Failed rejected BRI NT: SPID Negotiations failed MAJOR SPID Negotiation failed resetting the link BRI LT: SPID <spid> received MAJOR Unknown SPID received NOT IN LIST BRI NT: SPID Negotiations failed MINOR SPID Retry in progress Retrying No SPID matches the call profile: WARNING No matching SPID found <called number><call type> No SPID with free B channels WARNING No Matching SPID found matches call type: <call type> LT: Tried to call unregistered SPID WARNING SPID Unregistration attempted <spid> Configured BRI as LT NORMAL BRI LT configuration successful Configured BRI as NT NORMAL BRI NT configuration successful Rejected an incoming call for an NORMAL Call Rejected unregistered SPID D channel is UP NORMAL D Channel UP Released: No longer an ISDN line NORMAL ISDN line released No outgoing B channel available NORMAL No B channels for call for call to <number> Configured PRI as central office NORMAL PRI CO configuration successful emulator Configured PRI as CPE NORMAL PRI CPE configuration successful BRI NT: Spid <spid> registered NORMAL SPID registered BRI LT: All SPIDs registered NORMAL SPID Registration complete BRI NT: All SPIDs registered NORMAL SPID Registration complete BRI LT: Registering SPID <spid> NORMAL SPID Registration in progress BRI NT: Registering SPID <spid> NORMAL SPID Registration in progress Call to <called number> declared INFO Call busy busy after leaving Atlas Call to <called number> refused: INFO Call busy Busy Call to <called number> cleared INFO Call cleared from Atlas end Call to <called number> INFO Call connected connected Call to <called number> INFO Call disconnected disconnected by far end Call not accepted to <called INFO Call not accepted number>: No channel available Call to Atlas: <called number> INFO Call received received Call to <called number> ringing INFO Call ringing Dialing <called number> INFO Dialing number Incoming call to <called number> accepted INFO Incoming call accepted

8 of 10 8/30/2006 4:35 PM Incoming call to <called number> refused INFO Incoming call refused Table 7. Circuit Backup Events Circuit Backup Attempt MAJOR Outgoing backup call was unsuccessful Failed Circuit Backup Test Call Failed MAJOR Outgoing backup test call was unsuccessful Attempting Circuit Backup MINOR Circuit Backup call attempted to restore data circuit Circuit Backup Active MINOR Port is currently in backup Circuit Backup Deactivated, Primary Restored MINOR Port was in backup, but primary data function was restored Circuit Backup Data Alarm Active MINOR Inband keep alive messages were disrupted or corrupted Circuit Backup Data Alarm Cleared MINOR Inband keep alive messages are functioning properly Circuit Backup Test Call Originated INFO Circuit Backup test call was attempted by the unit Circuit Backup Test Call Connected INFO Circuit Backup test call was successfully connected to backup site Circuit Backup Test Call Passed INFO Circuit Backup test call was successfully maintained for test period Table 8. DP Outgoing Signaling Events TX Set Rx ABCP <> Tx ABCD <> 1 INFO Atlas changed signal bits on port RX Change Rx ABCD <> Tx ABCD <> INFO Equipment connected to port changed signal bits 1 The Atlas series uses only AB signaling bits. The CD signaling bits are a copy of the AB values. These values are shown in hexadecimal notation. For example, if AB signal bits are 01, then the total signal bits would be 01 01. Putting that in hexadecimal notation results in an event of Tx set Rx ABCD 0x05. ISDN Cause Codes In addition to the above events, certain recognized ISDN cause codes are sent to the Event Log from the ISDN message facility during ISDN Events, L2 Messages, and L2 Formatted event categories. Table 9 lists the codes applicable to the Atlas Series and the minimum category required for logging the cause code event. Table 9. ISDN Cause Code Events Cause Code Event Category Code ACCESS_INFO_DISCARDED WARNING 43 BAD_INFO_ELEM MAJOR 99 BEAR_CAP_NOT_AVAIL MINOR 58 CALL_REJECTED INFO 21 CAP_NOT_IMPLEMENTED MINOR 65 CHAN_NOT_IMPLEMENTED MINOR 66 CHANNEL_UNACCEPTABLE INFO 6

9 of 10 8/30/2006 4:35 PM DEST_OUT_OF_ORDER INFO 27 FACILITY_NOT_IMPLEMENTED MAJOR 69 FACILITY_NOT_SUBSCRIBED MNOR 50 FACILITY_REJECTED INFO 29 INCOMING_CALL_BARRED MINOR 54 INCOMPATIBLE_DEST MAJOR 88 INTERWORKING_UNSPEC WARNING 127 INVALID_CALL_REF MAJOR 81 INVALID_ELEM_CONTENTS MAJOR 100 INVALID_MSG_UNSPEC MAJOR 95 INVALID_NUMBER_FORMAT INFO 28 MANDATORY_IE_LEN_ERR MAJOR 103 MADATORY_IE_MISSING MAJOR 96 NETWORK_CONGESTION WARNING 42 NETWORK_OUT_OF_ORDER WARNING 38 NO_CIRCUIT_AVAILABLE WARNING 34 NO_ROUTE INFO 2 NO_USER_RESPONDING INFO 18 NONEXISTENT_MSG MAJOR 97 NORMAL_CLEARING INFO 16 NUMBER_CHANGED INFO 22 OUTGOING_CALL_BARRED MINOR 52 PRE_EMPTED WARNING 45 PROTOCOL_ERROR MAJOR 111 REQ_CHANNEL_NOT_AVAIL WARNING 44 RESP_TO_STAT_ENQ INFO 30 SERVICE_NOT_AVAIL MINOR 63 TEMPORARY_FAILURE WARNING 41 TIMER_EXPIRY MAJOR 102 UNASSIGNED_NUMBER INFO 1 UNSPECIFIED_CAUSE INFO 31 USER_BUSY INFO 17 WRONG_MESSAGE INFO 98 WRONG_MSD_FOR_STATE MAJOR 101 Cause Code Log Entries Cause Code IEs that are non-q.931 (i.e., the Coding Standard field is not 0) are logged with the following format: <message> : <coding standard> code <cause code> The coding standard field is one of the following: Reserved, National, or Local. Each Cause Code IE log entry ends with a location designation. Table 10 shows these designations. Tables 11 through Table 13 provide listings of system events. Table 10. Cause Code Log Entry Location Designations INTL INWK LN LPN RLN RPN Code Location International network Network beyond internetworking point Public network serving the local user Private network serving the local user Public network serving the remote user Private network serving the remote user

10 of 10 8/30/2006 4:35 PM TN U Transit network User Table 11. ISDN L2 Messages <message contents> INFO ISDN Layer 2 (LAPD) Message 1 1 Provides a hex dump of the entire LAPD frame. Table 12. ISDN Call Control Messages Host> > CC <tag><call ID> <message> INFO ISDN Call Control Messages CC> > Host <tag><call ID> <message> INFO ISDN Call Control Messages Table 13. Source: ISDN Information Elements <message contents> INFO ISDN Information Element 1 1 Provides a hex dump of the ISDN IE sent with a call control message.