G-930 RS-232/485/422 to wireless Zigbee



Similar documents
HAC-LM Series Low Power Data Radio Module

HAC-UM Series SHENZHEN HAC TECHNOLOGY CO., LTD. HAC-UM Series. Version 2.3C SHENZHEN HAC TELECOM TECHNOLOGY CO., LTD

Contents Chapter 1: Introduction... 3 Chapter 2: Ethernet (LAN)... 5 Chapter 3: ZigBee Wireless Connection Options... 7

Bluetooth to Serial Adapter

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2

1.1 Connection Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking

WIRELESS INSTRUMENTATION TECHNOLOGY

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

USB to RS-422/485 Serial Adapter

s!nus-elektrotechnikai bt. Industrial IT & Automation

Cisco Aironet Wireless Bridges FAQ

F2103 GPRS DTU USER MANUAL

Single channel data transceiver module WIZ2-434

Rev GSM base station. Installation instructions

TK800-Series Industrial GPRS / UMTS / LTE Router

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite:

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

Wireless DMX Connector

RJ45 Shielded (standard) port pinout. CS9000, Jetstream , Lanstream 2000, RTA8/RJX, RRC16, MTA8/RJX & SXDC8/RJX

MANUAL FOR RX700 LR and NR

M72. Quectel Cellular Engine. EVB User Guide M72_EVB_UGD_V1.0

Modbus Communications for PanelView Terminals

Wifi Web Server Module w TF Socket User s Guide

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

AC Wi-Fi Range Extender RE355. Highlights. Description

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

Communication Setup Application Note

Bluetooth HC-06 with serial port module Easy guide

Guangzhou HC Information Technology Co., Ltd. Product Data Sheet

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Software User Guide UG-461

Bluetooth UART/RS232 Module

Building a Basic Communication Network using XBee DigiMesh. Keywords: XBee, Networking, Zigbee, Digimesh, Mesh, Python, Smart Home

ACRS 2.0 User Manual 1

A RF18 Remote control receiver MODULE

LBNP RS-232/485/422 serial device server. User manual

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited

Introduction: Implementation of the MVI56-MCM module for modbus communications:

USER MANUAL V5.0 ST100

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

The Answer to the 14 Most Frequently Asked Modbus Questions

RN-XV-RD2 Evaluation Board

Using Xbee in Serial Communication

Disclaimers. Important Notice

TOSR0X-D. USB/Wireless Timer Relay Module. User Manual. Tinysine 2013 Version 1.0

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

AC 750. Wi-Fi Range Extender RE210. Highlights. Description

Rack mounted telephone- and leased line modem for industrial applications

Process Control and Automation using Modbus Protocol

Driver Pant 8 and antenna switcher Ant 8. User manual

How To Connect A Directsofl To A Powerpoint With An Acd With An Ctel With An Dm-Tel Modem On A Pc Or Ipad Or Ipa (Powerpoint) With A Powerline 2 (Powerline

Indoor / Outdoor Antenna

AC Wi-Fi Range Extender RE450. Highlights. Description

AP60. 9 Wireless. Wireless-b/g/n Long Range PoE Access Point. Wireless-b/g/n Long Range Radio. Passive PoE and 4-LAN Ports. IP Finder Management 4 LAN

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

Telephone- and leased line modem for industrial applications TD-36

GPRS M-Bus Master. User Manual. An Economical and Practical Solution For Remote Automactic M-Bus Smart Meter Reading by GPRS In The Worldwide!

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

RN-WIFLY-EVAL-UM. WiFly Evaluation Kit Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM Version 1.32r 10/9/2012 USER MANUAL

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS

xpico Wi-Fi Embedded Device Server Evaluation Kit Quick Start Guide

Bluetooth to serial HC-06 wireless module

Setting Up the ZigBee Ethernet Gateway

Application/Connection Examples

User Manual IC-485AI

Contents. 2 NP560-NP562 Installation Guide YML821 Rev1

PS 155 WIRELESS INTERCOM USER MANUAL

Serial over Ethernet Device Server. User s Manual

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

Guangzhou HC Information Technology Co., Ltd. Product Data Sheet

Guangzhou HC Information Technology Co., Ltd. Product Data Sheet

Hardware Reference. Linux Device Server IGW/922 with DIL/NetPC ADNP/9200

M2M I/O Modules. To view all of Advantech s M2M I/O Modules, please visit

ZC-24DO CANopen I/O Module: 24 Digital Outputs

RFID MODULE Mifare Reader / Writer SL031 User Manual Version 2.7 Nov 2012 StrongLink

5GHz 300Mbps 13dBi Outdoor CPE

(USR-TCP232-T, USR-TCP232-2) (USR-TCP232-S, USR-TCP232-D) (USR-TCP232-24, USR-TCP ) (USR-TCP , USR-TCP ) File version: V3.

User manual Compact Web PLC WP240 series IEC-line

SIM808 V2.2.5 user manual V1.2. Electrodragon.com

Master-Touch and ValuMass. Modbus Communications. INSTRUCTION MANUAL (Rev. 2.1)

RC2200DK Demonstration Kit User Manual

AC Wi-Fi Range Extender RE580D. Highlights

1-Port R422/485 Serial PCIe Card

Design and Implementation of Home Monitoring System Using RF Technology

The Foundation User Manual LED Battery Slim Par Fixture (RGBA, DMX 7Ch/4CH)

RDF1. RF Receiver Decoder. Features. Applications. Description. Ordering Information. Part Number Description Packages available

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide

USER MANUAL V5.0 VT300

Business/Home GSM Alarm System. Installation and User Manual

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

[WIR-1186] 865MHz-869MHz Wireless Module(version 3.0) (3.3V)

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Elettronica dei Sistemi Digitali Costantino Giaconia SERIAL I/O COMMON PROTOCOLS

3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T PIN6 T PIN7 R+ PIN8 R-

RS-232 COMMUNICATIONS

Microchip Technology. February 2008 Valerio Moretto Slide 1

Transcription:

G-930 RS-232/485/422 to wireless Zigbee I.Overview: G-930-ZIGBEE wireless communication module is strengthen ZIGBEE module, integrated according with ZIGBEE protocol RF transceiver and CPU,which has the far communication distance with the strong anti-interference ability making internet flexible etc., advantage and feature;to reach the data transparent transmit between the 1 point to multi-point and multi-point to multi-point;which can make the star and MESH type net network structure G-930-ZIGBEE communication module realizing serial port RS232/485/422 data transparent transmit,which can realize multipoints network communication except the common point to point data communication function G-930-ZIGBEE communication module divide into the core coordinator router and terminal nodes,which have the different network function,core coordinator is the core nodes of the network which is responsible for the network launch and organization network maintenance and managing functions;the router is in charge of the data transmit,and the terminal node is only in charge of this node data sending and receiving The core coordinator router and terminal node 3 types equipments are the same in the hardware structure except the equipment parameters different

II Product Features data interface:rs232/422/485 SMA female antenna interface. carrier frequency:2.4ghz ISM worldwide free frequency segment,frequency zone between 2400M-2485M modulation type:dsss wireless channel:16 channel check:csma/ca network:star type tree type link type net type single net capacity:65535 nodes sending type:the broadcast sending or the object address sending transmit speed:1200-115.2kbps adjustable working power:dc9v-30v 150mA(max) transmit distance:wireless 2.4GHz carrier 1000m(empty distance) RS-232 5m(1200bps-115200bps) RS-485/422 1200m(1200bps-115200bps). reception sensitivity:-105dbm. emitting rate:25dbm. antenna connecting:5dbm SMA male rubber antenna. protection grade:power supply interface RS232/422/485 interface with 2KA lightning protection. dimension:1 97mm 65mm 26mm(without antenna) weight: 120 g working environment:-40~85,relatively humidity 5% to 95%) III Dimension and electrical appliance interface G-930 with 2 sides female serial ports cables,rs-485/422 is cable terminals output RS-232C pin assignment DB9 Male/hole(PIN) RS-232C interface signal 2 Receiving data SIN(RXD) 3 Sending data SOUT(TXD) 5 GND 1,4,6,7,8,9 none

RS-485/RS-422 output signal and wire terminals pin assignment Wire post Output signal RS-422 full duplex RS-485 half duplex wire wire 1 T/R+ sending(a+) RS-485 (A+) 2 T/R- Sending (B-) RS-485 (B-) 3 RXD+ receiving(a+) none 4 RXD- receiving(b-) none IV Device assignment instruction 4.1 connect the equipment and the computer Connect the power supply to the power input to make sure its correct and stable, then switch the G-930 equipment interface to RS232 port and connect the computer to confirm the wires correct 4.2 open the serial port to adjust the software 1 open the computer disc to find a serial port adjust assistant,then select the right serial port, set its belonging:baud rate 38400 data bit 8 check NONE the stop position 1 flow control: none; 2 equipment on;press CFG assignment button3 seconds 3 alarm light and running light blink at the same time;the system enter assignment status 4.3 allocation parameters 1 equipment address allocation: option ID range Allocation instruction remarks MAC_ADDR 0000 FFFE The same network can not Core node address have the same address node Fix 0000 Each Z-Bee equipment has the sole address identification,the same network system can not have the same address node,the equipment address adopts 2 bytes address. 2 node type set: option Device type Allocation instruction remarks PAN_Coord Core node Data center ROUTER Relay router Also with terminal device function END_DEVICE Terminal device

3 network type set: option Network instruction Allocation instruction remarks MESH Net network Masterslave network STAR LINE PEER 4 network ID: Star network Link network Equal network must have the sole core node Non mastersalve network,no core The network type must set the same in the same network option ID range Allocation instruction remarks ID must be same in the NET_ID 0000 FFFF same network remarks:all devices ID must be same in the same communication network 5 frequency point allocation: option range remarks 0-F 1 : 2.410GHz 2 : 2.415GHz 3 : 2.420GHz 4 : 2.425GHz 5 : 2.430GHz 6 : 2.435GHz 7 : 2.440GHz 8 : 2.445GHz 9 : 2.450GHz A : 2.455GHz B : 2.460GHz C : 2.465GHz D : 2.470GHz E : 2.475GHz 0 : 2.405GHz Introduce using 4.9.E.F to avoid WIFI interference F : 2.480GHz remarks:all devices working frequency point must be same in the same communication network, and :don t set it to be automatic 6 address code: option Data type Allocation instruction ASCII ASCII code Both address type optional HEX 16 bytearray

7 sending type assign: option Sending mode Allocation instruction BROADCAST broadcast No need object address MASTER SLAVE masterslave Send data to the fixed object address device Core node needs the object address;no core node no POINT POINT Point to point needs object address, default sending to core node remarks Object address is 2 bytes MAC address,adding it before the data wrap. 8 baud rate set: Baud rate range Allocation instruction remarks 1200 115200 1200 115200 Select matching baud rate Default 9600 remarks:factory default 9600,this Baud rate is communication baud rate,which should be seperated from the above content mentioned entering allocation Baud rate 9 data check test: option Check type Allocation instruction NONE Non check EVEN Even check Selecting matching check type ODD Odd check 10 data bit set: option Data type Allocation instruction 7+1+1 7 bit data+1 bit check+1 bit stop Select according to the data check 8+0+1 8 bit data+no check+1 bit stop set combination 8+1+1 8 bit data+1 bit check+1bit stop 8+0+2 8 bit data+no check+2 bit stop 11 data source address: option Data source address Allocation instruction NOT OUTPUT No output source address HEX 16 Bytearray output Default to be no output ASCII ASCII output

V common allocation cases 5.1 allocation parameters attention Central main station address is fixed 0000,following station address 0001-FFFE can be set at random,but 2 relays address can not be the same,otherwise it can not communicate All devices frequency points and network ID must be the same at the same network;baud rate check data bit must match with the terminal device 5.2 some common allocation projects (1)transparent transmit Master station allocation:node type is core node,sending mode is broadcast Slave allocation:node type is relay router or terminal node, sending mode is master-slave (2)transmit as per the object address 1master-slave mode Master station allocation:node type is core node,sending mode is master-salve Slave allocation:node type is relay router or terminal node,sending mode is master-salve Under this mode,if master station sends data to the slave station,the object address before the data is needed;the address is not needed if sending data from salve station to the master station, which will send regularly 2point to point mode Only 2 devices communication under this mode with no core node,both object address are needed before the 2 devices sending data (remarks:separate his mode from the point to point communication) VI running instruction 6.1 indication light instruction G-930-ZBEE wireless communication device supply 4 working status LED indication interface,which are running network alarm and power supply,4 indication lights status and meaning: Indicator light Indicating status Indicating meaning Blink every 1 System running normally Running second off System no running,power off or system fault Network on Core node fault Normally on;entering to the network from the node off No link to network Alarm off Work normally Normally on System abnormally or entering special status Power supply Normally on Power on Off Power off

6.2 device connect instruction (1) G-930 as the core main station to connect the PC (2) G-930 as the relay router function(power on is ok),can set network to transmit (3) G-930 as the terminal node to terminally connect with the user (this node can be set to relay router with terminal function) 6.3 fault instruction Fault methods LED off Check the device power on or not 4 LED lights normally on Device main chipset damanged,contact the supplier to check Device smoking Power supply too high,damage probably,power off to check Device not setting Read the product operating instruction carefully,check and change network the relative parameter To check if entering the allocation status(power light normally on, running light and alarm light blink ); confirm super terminal Device no allocation belonging allocation correct and connect successfully;to confirm if the cable correct or not,no reverse connect;confirm the serial port no. selection correct VII attentions (1) is the power supply under the required voltage range,otherwise its module will be damaged easily (2) this module without water protection,to do the water protection work well (3) no reverse connection of the power supply +/- polarity,otherwise the module damange (4) the module mounting environment should try to avoid ESD,no contact between the antenna and the metal objects. VIII attached list name quantity(unit) G-930 4Pin wire terminals Rubber antenna DB9 Female serial port wire Color box Pearl wool Small DC Certificate Maintenance cared