GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS ~GSM SHELTER CONTAINERS ARE PROCUDED ACCORDING TO THE DEMANDED SIZE.~ (W x L x H) Page1
GENERAL FEAUTURES Environmental Conditions : Maximum outdoor temperature +55 C, Relative humidity 100%, Wind speed durable 175 km/h, Fully resistant against to dust, sand and rain, Corrosion- resistant against acid rain, salt, contamined industrial waste and weather conditions, Fully resistant against to plants, insects, rodent, micro-organisms and their compositions. Loading : Container roof able to carry loads, up to 6 meters vertically like transmission pole. Air conditioning unit will be put top of the roof where it is necessary. Cranes can be easily carry the containers with fully-load or not using by loading-holes top on the containers. Also, forklift pallet places can be manufactured according to the customer s demand. Operating Conditions : Inside of the GSM Shelter Container s equipment, working environment temperature would be +5 to +40 C and ambient relative humidity 85%. Main Structural Components : i) INSULATION Wall panels insulation will be B-class poly-urethane (PU), or EPS, roof and frame insulation will be B-class PU / EPS / Glass wool / Rock wool. According to the geographical conditions and technical specifications for the project with considering the related standards. GSM Shelter Container s average heat transfer coefficient value will not be bad 0.32 W / m² K. ii) WALL PANELS Wall panels will be PU / EPS / Glass wool / Rock wool sandwich panels according to the technical specifications. Sandwich panel's most important feature is used between the inner and outer plates, pu / eps production of material in a single piece (monoblock). Outer Layer : 0.50 mm thick, 5 micron primer + 20 micron polyester paint finish, polyethylene film coated galvanized sheet metal. Inner Surface : 0.50 mm thick, 5 micron primer + 20 micron polyester paint finish, polyethylene film coated galvanized sheet metal. Page2
PU and EPS panels are B-classed fire resistant material. Galvanized steel thickness 150-200gr/m² PU density 40-42 kg/m³ EPS density 28-30 kg/m³ iii) BASE CHASSIS Base Chassis : Special shaped and cold formed ready made steel profiles. It will be painted electrostatic powder paint or primer painted. Outer Surface : Galvanized trapezoidal unpainted steel sheet Insulation : PU/EPS/Glass wool/rock wool Interior Surface : Cement bonded particle-board/plywood/mdf etc. Floor Covering : Antistatic PVC flooring Note : Material thickness will be choosen according to the geographical conditions and technical specifications for the project with considering the related standards. iv) TOP CHASSIS (CEILING) Top Chassis : Special shaped and cold formed ready made steel profiles. It will be painted electrostatic powder paint or primer painted. Outer Surface : Galvanized trapezoidal unpainted steel sheet Insulation : PU/EPS/Glass wool/rock wool Inner Surface : Cement bonded particle-board/gypsum board/plywood/mdf etc. Note : Material thickness will be choosen according to the geographical conditions and technical specifications for the project with considering the related standards. Lifting : To able to lift or move entire load with lifting straps/eyebolts/iso edges/lifting corners. Rain (Water) Drainage System: With slope of the roof (free flow) or With roof drainage system and drinage channels Note : If demanded ice-shelter application will be used. v) CORNER COVERING Special shaped and cold formed ready made steel profiles. It will be painted electrostatic powder paint or primer painted. Page3
vi) DOORS & WINDOWS Windows & Doors Frame : Rebated application or cold-formed powder-coated galvanized steel sheet and frames are case sealing ribbed will be used. Windows: PVC Windows will be used (Windows are not recommended for use in GSM Shelter containers.) Outer Doors NOTE : If demanded; : Steel doors. Fly insect wire, Window shutters/blind, Hydraulic door trap, Vent above the door or panel, Rain dropper, Loophole etc. Supplying and installation of accessories according to the demand. vii) ELECTRICAL SPECIFICATIONS : 1st class electrical materials will be used according to the technical specifications for the project with considering and related Turkish and/or European standards. Cabling : Surface mounted (Easily facilitates operation to the cables.). Rigid PVC cable channels will be used. Lighting : Interior and outer armatures will be used according to the technical specifications for the project with considering and related Turkish and/or European standards. Note : If demanded, supplying and installation below materials; Socket and switch, Equipotential busbar, Earthing bar, Earth leakage relay (parafadur), Container compartment fuse panel etc. Page4
viii) ACCESSORIES : According to the technical specifications for the project with considering and related Turkish and/or European standards.; Container balance (adjustable) feet, Door grill, Door stoppers, Fire dedector, Motion dedector, Air conditioner unit, Air conditioner shelter (For outer unit), Air conditioner stand, Pol clamps etc. Supplying and installation of accessories according to the demand. Folding table, C-ray Roxtec unit, Exhaust fan unit, Insulator dropper, Folding stool, Folding table, Documentation box, Page5
Architectural Drawing : Images : Page6
GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS O R AY PR EF AB R IC AT ED : Page 7 The meeting point of effective solutions with professionalism HEADQUARTER OFFICE : Cevizlidere mah. 1243. Sk (Eski 7. Sk.) D. Palmiye İş Merkezi No:4/2 Balgat Ankara / TURKEY SHOWROOM : Hurdacılar Sitesi A/5 Blok No : 845 Yenimahalle Ankara / TURKEY FACTORY - I : ASO 2. Organize Sanayi 2005. Cad. No : 7 Temelli Ankara / TURKEY FACTORY - II : ASO 2. Organize Sanayi 2005. Cad. No : 3 Temelli Ankara / TURKEY