ORAY PREFABRICATED GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS



Similar documents
BROWACOM PRODUCTS. Our web-pages can be found from:

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

LOW COST PREFABRICATED CONSTRUCTION SYSTEM

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

SECTION TABLE OF CONTENTS. H Proposed Material, Product or Equipment Substitution Request

All Weather Hall. Efficient, multipurpose & quick to build

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

RPV - RP - RA air handling units

MTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Asphalt Shingle Application Requirements

CHAPTER 7: Building Systems ROOFING SYSTEMS

Morgue refrigeration unit

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

55 OUTODOOR TOTEM Floorstanding professional Display Enclosure

CLASSIFICATION OF REACTION TO FIRE IN ACCORDANCE WITH EN :2007

Networking Cabinets > Part No Capacity Available Colors Height(mm) Width(mm) Depth(mm)

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Manual lifting and handling

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Screen Enclosure Protect your Screen against: rain, temperature, vandalism damage and theft

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Master Panel 1000 R5 Roof

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape

Preventing Ice Dams on Roofs

Company DUOL. Dušan Olaj CEO

Master Panel 1000 W Wall

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

DENVER MODEL 30 X 30 SPECIFICATIONS

Harness Your Energy NOW AVAILABLE! the new. ASW-58A-22/30 Solar Thermal Collector

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

TAS ITA. DA1, dual csatlakozásfor thermostat. For control of 2 heaters on 1 thermostat. * * * * * * * * Thermostat for CH 12/18

ABSeam Panel Overview and Installation Instructions

Assessing Curtain Walls

BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping.

Composite Panel Firewall Systems

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

Fiera di Vicenza S.p.A. offers fitted booth areas in compliance with fire Safety measures. (Features and dimensions are purely indicative) 70 /sqm

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad

INSTRUCTION FOR ASSEMBLY. 150x180 v Traditional sauna cabin

COLORADO MODEL. 35 x 65 SPECIFICATIONS

Nominal Life Expectancy for Building Components

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

LAYING BLOCK AND BRICK

TPM 006/99 Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER

8 EXTRA LIGHT GRC SANDWICH ELEMENTS FOR ROOFING IN INDUSTRIAL BUILDINGS

Building Owners Guide to a Duro-Last System!

Linkeo 19" freestanding cabinets

Coldrooms designed for your application

PAAM COMMERCIAL PRIVATE LIMITED

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Cable Trays Technical Instructions & Specifications

QUICK BUILD DEMOUNTABLE CONTAINERS & WAREHOUSES. Construct the Quick-Build Container in under 5 minutes!

Installation Instructions

SECTION MORTUARY REFRIGERATORS

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Roof Curbs, Extensions and Equipment Supports

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SEM Model 23/5 GREEN VALUE KIT Medium / Heavy Duty Disintegrator & Briquettor System

COMMONLY USED RESIDENTIAL BUILDING CODES

SERVER ROOM CABINET INSTALLATION CONCEPTS

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

Confort 26. Sliding Systems. Sapa Building System

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Mechanical arms, belts and sheets

19 DYNAmax Free Standing Server C A B I N E T s

Switchboard system. NorLine 800

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

Optiffuser. High-performance, high bandwidth lightweight 1D diffuser.

September 3, Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

CHANNEL LETTERING INDOOR & OUTDOOR TRADE SHOW DISPLAYS CONSTRUCTION SIGNAGE VEHICLE GRAPHICS REAL ESTATE / DISPLAYS WINDOW GRAPHICS POSTERS

Rockwool Flexi Insulation Application Guide

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

MONDOATHENS BASKETBALL SET (Reference PK110)

air water oil antifreeze grease diesel fuel kerosene oxygen-acetylene lpg-methane electricity Hose & cable reel

SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN Phone (260) Sales Fax (260)

FAQs-Main switchboard design criteria

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Operators manual Basic water heater

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Modular Access Floor for Data Center. From Rack to Row to Room to Building

BETONYP building boards. The modern way of living.

SPILL CONTAINMENT PALLETS

understanding medium frequency induction melting furnace and its components

Dock Hardware & Accessory Products Catalog

Transcription:

GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS ~GSM SHELTER CONTAINERS ARE PROCUDED ACCORDING TO THE DEMANDED SIZE.~ (W x L x H) Page1

GENERAL FEAUTURES Environmental Conditions : Maximum outdoor temperature +55 C, Relative humidity 100%, Wind speed durable 175 km/h, Fully resistant against to dust, sand and rain, Corrosion- resistant against acid rain, salt, contamined industrial waste and weather conditions, Fully resistant against to plants, insects, rodent, micro-organisms and their compositions. Loading : Container roof able to carry loads, up to 6 meters vertically like transmission pole. Air conditioning unit will be put top of the roof where it is necessary. Cranes can be easily carry the containers with fully-load or not using by loading-holes top on the containers. Also, forklift pallet places can be manufactured according to the customer s demand. Operating Conditions : Inside of the GSM Shelter Container s equipment, working environment temperature would be +5 to +40 C and ambient relative humidity 85%. Main Structural Components : i) INSULATION Wall panels insulation will be B-class poly-urethane (PU), or EPS, roof and frame insulation will be B-class PU / EPS / Glass wool / Rock wool. According to the geographical conditions and technical specifications for the project with considering the related standards. GSM Shelter Container s average heat transfer coefficient value will not be bad 0.32 W / m² K. ii) WALL PANELS Wall panels will be PU / EPS / Glass wool / Rock wool sandwich panels according to the technical specifications. Sandwich panel's most important feature is used between the inner and outer plates, pu / eps production of material in a single piece (monoblock). Outer Layer : 0.50 mm thick, 5 micron primer + 20 micron polyester paint finish, polyethylene film coated galvanized sheet metal. Inner Surface : 0.50 mm thick, 5 micron primer + 20 micron polyester paint finish, polyethylene film coated galvanized sheet metal. Page2

PU and EPS panels are B-classed fire resistant material. Galvanized steel thickness 150-200gr/m² PU density 40-42 kg/m³ EPS density 28-30 kg/m³ iii) BASE CHASSIS Base Chassis : Special shaped and cold formed ready made steel profiles. It will be painted electrostatic powder paint or primer painted. Outer Surface : Galvanized trapezoidal unpainted steel sheet Insulation : PU/EPS/Glass wool/rock wool Interior Surface : Cement bonded particle-board/plywood/mdf etc. Floor Covering : Antistatic PVC flooring Note : Material thickness will be choosen according to the geographical conditions and technical specifications for the project with considering the related standards. iv) TOP CHASSIS (CEILING) Top Chassis : Special shaped and cold formed ready made steel profiles. It will be painted electrostatic powder paint or primer painted. Outer Surface : Galvanized trapezoidal unpainted steel sheet Insulation : PU/EPS/Glass wool/rock wool Inner Surface : Cement bonded particle-board/gypsum board/plywood/mdf etc. Note : Material thickness will be choosen according to the geographical conditions and technical specifications for the project with considering the related standards. Lifting : To able to lift or move entire load with lifting straps/eyebolts/iso edges/lifting corners. Rain (Water) Drainage System: With slope of the roof (free flow) or With roof drainage system and drinage channels Note : If demanded ice-shelter application will be used. v) CORNER COVERING Special shaped and cold formed ready made steel profiles. It will be painted electrostatic powder paint or primer painted. Page3

vi) DOORS & WINDOWS Windows & Doors Frame : Rebated application or cold-formed powder-coated galvanized steel sheet and frames are case sealing ribbed will be used. Windows: PVC Windows will be used (Windows are not recommended for use in GSM Shelter containers.) Outer Doors NOTE : If demanded; : Steel doors. Fly insect wire, Window shutters/blind, Hydraulic door trap, Vent above the door or panel, Rain dropper, Loophole etc. Supplying and installation of accessories according to the demand. vii) ELECTRICAL SPECIFICATIONS : 1st class electrical materials will be used according to the technical specifications for the project with considering and related Turkish and/or European standards. Cabling : Surface mounted (Easily facilitates operation to the cables.). Rigid PVC cable channels will be used. Lighting : Interior and outer armatures will be used according to the technical specifications for the project with considering and related Turkish and/or European standards. Note : If demanded, supplying and installation below materials; Socket and switch, Equipotential busbar, Earthing bar, Earth leakage relay (parafadur), Container compartment fuse panel etc. Page4

viii) ACCESSORIES : According to the technical specifications for the project with considering and related Turkish and/or European standards.; Container balance (adjustable) feet, Door grill, Door stoppers, Fire dedector, Motion dedector, Air conditioner unit, Air conditioner shelter (For outer unit), Air conditioner stand, Pol clamps etc. Supplying and installation of accessories according to the demand. Folding table, C-ray Roxtec unit, Exhaust fan unit, Insulator dropper, Folding stool, Folding table, Documentation box, Page5

Architectural Drawing : Images : Page6

GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS O R AY PR EF AB R IC AT ED : Page 7 The meeting point of effective solutions with professionalism HEADQUARTER OFFICE : Cevizlidere mah. 1243. Sk (Eski 7. Sk.) D. Palmiye İş Merkezi No:4/2 Balgat Ankara / TURKEY SHOWROOM : Hurdacılar Sitesi A/5 Blok No : 845 Yenimahalle Ankara / TURKEY FACTORY - I : ASO 2. Organize Sanayi 2005. Cad. No : 7 Temelli Ankara / TURKEY FACTORY - II : ASO 2. Organize Sanayi 2005. Cad. No : 3 Temelli Ankara / TURKEY