Nearly real-time monitoring system of TABOO seismic network activity.



Similar documents
ERMES. Monitoring of radon in geogas at the Gran Sasso National Laboratory

Network of European Research Infrastructures for Earthquake Risk Assessment and Mitigation. Report

Automated control procedures and first results from the temporary seismic monitoring of the 2012 Emilia Sequence

Sismalog S t a n d - a l o n e S e i s m o g r a p h

Integrated Data Storage and Database

SNMP-NET Client Shutdown Management Software for Windows 2000/XP/2003 User s Manual

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

Deliberant.com, Technology review

GE Security. FHSD Monitor / Web Server user manual

UPSentry Smart User s Manual. Shutdown Management Software. for Mac OS X 10.2

Procedure Automa-che e Modulari di Analisi dei Da- Sismici. Is#tuto Nazionale di Geofisica e Vulcanologia


APC series overview. Copyright 2014 Deliberant LLC

Automated control procedures and first results from the temporary seismic monitoring of the 2012 Emilia sequence

FT-1000/GPS-N. System of remote monitoring and control of physical

Instrumentation and Real Time Monitoring of a Landslide on Highway No. 302 Near Prince Albert, Saskatchewan

Continuous, remote monitoring and logging of electromagnetic fields

InsightPower Client. Shutdown Management Software for Windows 2000/XP/2003. User s Manual

Bandwidth-dependent transformation of noise data from frequency into time domain and vice versa

The new services in nagios: network bandwidth utility, notification and sms alert in improving the network performance

communication over wireless link handling mobile user who changes point of attachment to network

EDM Cloud Remote Monitoring Solutions. Crystal Instruments, January 2014

Seismic Networks in Canada

Environmental Monitoring: Guide to Selecting Wireless Communication Solutions

NMS300 Network Management System

Technical Manual. (TLT-2H GPS/GSM Vehicle Tracker) V1.5

Controller Automation, Model II+

Climate Ready Shade Operating Systems for residential applications.

Woods Hole Group, Inc. Oceanography and Measurement Systems Division INTEGRATED REAL-TIME MONITORING SYSTEM

Frequency selective monitoring and logging of environmental electromagnetic fields

Early Warning Book. Dipartimento di Scienze Fisiche - Università degli Studi di Napoli, Federico II, Napoli, Italy

Energy Communication Unit (ECU)

Remote Monitoring and Satellite Communications

An Innovative Concept to Manage GPS Reference Stations Network and RTK Data Distribution Globally

PD Monitor GIS. 24/7 Partial Discharge (PD) monitoring system for Gas Insulated Switchgear. Benefits NEW PRODUCT

Using the UPSMON-Plus Monitoring Software

- 1 - SmartStor Cloud Web Admin Manual

Station Notes for B001, golbeck01bwa2005

Quick Start Guide: Iridium GO! Advanced Portal

MOBILE ALERT MONITORING SERVICE TUTORIAL

Introducing Tripp Lite s PowerAlert Network Management Software

Datasheet. Powerful 2x2 MIMO airmax BaseStation. Models: M5, RM5-Ti, M3, M365, M2, RM2-Ti, M900. Advanced Software Technology to Maximize Performance

SyAM Software Management Utilities. Creating Templates

Radiological Assessment Display and Control System

STRUCTURAL HEALTH MONITORING AT ROME UNDERGROUND, ROMA, ITALY

Chapter 2 Dispatch Server

New technologies applied to Carrier Monitoring Software Systems. Juan Carlos Sánchez Integrasys S.A.

CARLETON UNIVERSITY Department of Systems and Computer Engineering. SYSC4700 Telecommunications Engineering Winter Term Exam 13 February 2014

Basic Wireless Configuration and Security

POSITION TRACKING SYSTEMS, INC. Product Summary

Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)

Solar Powered Wireless Sensors & Instrumentation: Energy Harvesting Technology Reduces Operating Cost at Remote Sites

m Antenna Subnet Telecommunications Interfaces

Title Page Web/SNMP Management SmartSlot Card

Pandora FMS 3.0 Quick User's Guide: Network Monitoring. Pandora FMS 3.0 Quick User's Guide

Mobile Network Performance Assessment Report Salalah Khareef Season 2015

Kokii BatteryDAQ. BMS Software Manual. Battery Analyzer Battery DAS

Wireless N 300 Mini USB Adapter. Model # AWLL6086 User s Manual. Rev. 1.0

Interactive Logging with FlukeView Forms

Configure Cisco Emergency Responder Disaster Recovery System

User Manual (UDTTV01 V 1.6

LB Sky Global. 92 Lobachevskogo St, Bld 92, Office 5, Moscow, Russia Tel/Fax 7(495) , Site:

Aeroqual Connect and Cloud

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Wireless Data Logger Monitoring Systems

GSM home alarm system s manual

Tube-U(G) Long-Range Outdoor IEEE g USB Adapter User s Guide

Continuous, remote monitoring and logging of electromagnetic fields

Tektronix RSA306 USB Spectrum Analyzer

D-RATS Training. D-RATS Lesson schedule

DLB 5-20 Outdoor Wireless Device DATASHEET. COPYRIGHT 2014 LigoWave

USB-500 Series Stand-Alone, Low-Cost Data Loggers

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

16 February Connected Worker

User Guide for the Volvo On Call mobile application

Impedance 50 (75 connectors via adapters)

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

An Overview of the National Earthquake Information Center Acquisition Software System, Edge/Continuous Waveform Buffer

Mapping the Tyrrhenian and Adriatic Mohos across the northern and central Apennine chain through teleseismic receiver functions

How To Check If Your Router Is Working Properly

Satellite technology delivers dependability for disaster crisis management

Logging of RF Power Measurements

High Power Programmable DC Power Supplies PVS Series

BONEMA TECHNOLOGIES PRODUCT FEATURES. The following training provides information on the Bonema product features.

OPENUPS. 6-30V Intelligent Uninterruptible Power Supply. Installation Guide. Version 1.0f P/N OPENUPS-06

Proactive Monitoring of Friction Management Systems Reduces Costs and Downtime

BiPAC 7800NL. Wireless-N ADSL2+ Firewall Router. Quick Start Guide

SNMP INTERFACES AND SOFTWARE FOR SINGLE-PHASE UPS

Quarterly Report to the Harry Reid Center NSHE-DOE Cooperative Agreement. Task ORD-FY04-006: Seismic Monitoring PI: John Anderson

SERVIZIO NEWS SPOTTER. e MOBILE TOOWAY 2. per informazioni numero verde

Product Description... 1 Internal Management Features... 3 Front Panel... 5 Watchdog Features... 7

Telemetry system for cathodic protection equipment of underground metal pipelines

Data Services and Web Applications

User s Manual Network Management Card

Measurement, analysis, and monitoring of RF signals

Coslight Hybrid Power System with Solar

Provide network RTK Services in a few simple steps

Network Management Card. User Manual

TAS (Tecnosoft Alarm System)

Networks, instruments and data centres: what does your seismic (meta-) data really mean? Joachim Wassermann (LMU Munich)

Transcription:

Nearly real-time monitoring system of TABOO seismic network activity. Marzorati S.* and TABOO working group * National Earthquake Centre, Ancona Istituto Nazionale di Geofisica e Vulcanologia

Nearly real-time monitoring system of TABOO: seismic network activity. Seismic Network Maintenance, Monitoring, Data quality check, Data analysis, site characterisation INGV-CNT Ancona staff: -Monachesi Giancarlo -Cattaneo Marco -D Alema Ezio -Frapiccini Massimo -Carannante Simona -Ladina Chiara -Marzorati Simone Earthquake National Center (INGV-CNT) Ancona staff TABOO GROUP 0 / 10

Data Transmission and Acquisition Ancona-INGV Acquisition Data Center Ancona INGV Acquisition Data Center - Wi-Fi networks and UMTS routers transmit continous seismic data in real time - The Data Acquisition is managed by Seiscomp3 server - Data Archive: MiniSEED TELECOMMUNICATION NETWORKS TABOO INGV Alto Tiberina Wi-Fi Hiperlan Local Radiolink seismic stations seismic stations MARCHE WAY Wi-Fi Radiolink 6.4 GHz SDH (155 Mbps) 1 / 10

REAL TIME Telemetry and Station STATUS Backbone node Real Time monitor -Netscout -Seiscomp3 Radiolink Seismic Station Telemetry Status NETSCOUT is a product of Ars Comm engineering company (www.arscomm.it) The software monitors the parameters and alarms of telecommunication networks in real time. Active No communication 2 / 10

REAL TIME Telemetry and Station STATUS Real Time monitor -Netscout -Seiscomp3 Seiscomp3 SCQCV client Seismometer status and a detailed view of Quality Control (QC) parameters: Delay, Latency, Offset, RMS, Gap,Timing of real time signals 2 / 10

Reboot by Remote Controls -Netscout-UC34a -Health Control UC34 -Seedlink GAIA2 -SMS UMTS router Netscout shows power station levels (voltage, power, temperature on site). If a radiolink backbone node doesn t work, we can try to stop and start the power station by a remote control push button Power Station Check at RadioLink backbone node backbone UC34a 3 / 10

Reboot by Remote Controls -Netscout-UC34a -Health Control UC34 H-UC34 GAIA2 ping -Seedlink GAIA2 -SMS UMTS router UC34 is a Control Unit of Ars Comm engineering company, devoted to check the connectivity between remote seismic station and backbone radiolink. A modified version communicates with INGV-GAIA2 data logger to monitor acquisition processes status Automatic Check of Connectivity and Acquisition at remote sites backbone Backbone node Radiolink 3 / 10

Reboot by Remote Controls -Netscout-UC34a -Health Control UC34 -Seedlink GAIA2 -SMS UMTS router Telnet connection with Linux O.S. in the GAIA2: Reset of the seismic station acquisition system -Stop and Restart of seedlink processes -Linux O.S. shutdown and reboot 3 / 10

Reboot by Remote Controls -Netscout-UC34a -Health Control UC34 -Seedlink GAIA2 -SMS UMTS router UR5 UMTS router used on seismic stations out of the WiFi network. The SMS service is available to reboot the UMTS router by Configuration Menu Text of the SMS from mobile phone: «reboot» UR5 UMTS router Reboot 3 / 10

Three-day monitor Nearly Real Time Status History -Power Supply -Tracked GPS Satellites -Gaps The last day The last week An automatic process on the Linux O.S. creates a file with power supply value registered by GAIA2 seismic data logger. By Crontab & SCP connection we extract and archive power supply values every 10 minutes. The power supply values are shown on three-day Monitor (updated every hour) to check the functionalities of the different power supply systems. Constant supply: Electrical Power Line on site Gradient supply: (methanol) fuel cell The last month All data Impulsive supply: Solar panels Power Supply Trends on each seismic station 4 / 10

Three-day monitor Nearly Real Time Status History -Power Supply -Tracked GPS Satellites -Gaps An automatic process on the Linux O.S. creates a file with tracked satellites value on the GPS system of the GAIA2 seismic data logger. By Crontab & SCP connection we extract and archive tracked satellites values every 10 minutes. The tracked satellite values are shown on three-day Monitor to check the functionalities of the seismic station GPS system. Seismic station GPS check 4 / 10

Yesterday monitor Nearly Real Time Status History -Power Supply -Tracked GPS Satellites -Gaps We apply «qmerge» Passcall software on each seismic channel to monitor the gap trends. The number of gaps are shown on «yesterday» monitor, but the whole gap history is archived. Gap trends check Satellite links in bad weather conditions (snow) 4 / 10

Seismometer Performance and Site Quality - Seismic Noise Probability Density Function (PDF) Evaluation of seismic noise over a long time by PQLX software (*McNamara and Buland, 2004) : trace statistics, Power Spectral Densities (PSD) and Probability Density Functions (PDF). PQLX server writes the results to a MySQL database for quick access Implementation at INGV-Ancona acquisition center: - PQLX server starts every day by crontab process - Data extraction tools allow to evaluate noise levels and statistics about subset of data (in ex., diurnal and nightly data) The stationary background noise is characterized by the highest probability of occurrence (mode) Mode: stable noise model for each station *McNamara, D.E. and R.P. Buland Ambient Noise Levels in the Continental United States Bull. Seism. Soc. Am., 94, 4, 1517-1527, 2004 5 / 10

Nearly Real Time Network Performance Nightly - Earthquake Magnitude Detection Map - Extraction of diurnal and nightly PSD every day by «expsdhour» PQLX tool - Evaluation of diurnal and nightly seismic noise mode at each station - Calculation of Earthquake Magnitude Detection Map from noise modes TABOO network: - Excellent detection threshold (negative magnitude) - Cultural seismic noise affects detection thresholds in daytime but << 1 for the whole network Diurnal Depth Z = 5 Km 6 / 10

Network Performance - 2 years Noise PDF stack and modes PQLX Data set: - TABOO area - Surface seismic station - 2 years of data at least Noise level Probability in TABOO area The distribution of seismic noise spans over 30-40 db but higher probability values range within 10 db Anomalous low frequency response for ATMC and ATLO station 7 / 10

Network Performance - TABOO 2 years Mode Low Noise Model (TB2yMLNM) PQLX Data set: - TABOO area - Surface seismic station - 2 years of data at least TB2yMLNM represents the minimum of the most occurring noise levels in TABOO area Model: The minimum of all the modes at each period (*McNamara and Buland, 2004) Diurnal and Nightly Models from diurnal and nightly modes: Diurnal Nightly Difference 5.0 ± 2.1 db between 1 and 25 Hz 8 / 10

Noisy Network Performance - Noisy and quiet stations The minimum noise model is reference to assess the quality of each station Quiet Station diurnal mode Station nightly mode Area between 10th and 90th percentile of PDF 9 / 10

Network Performance - Borehole seismic stations Winter local microseisms BAT3 borehole setup: Vertical array of seismic (2Hz) sensors Depth: 0, 50, 150, 250 m 250 m deep sensor BAT3 borehole performance (3 month statistic): the BAT3 mode values are smaller than TB2yMLNM at high frequency Good launch, Lauro! 10 / 10