CyTOF2. Mass cytometry system. Unveil new cell types and function with high-parameter protein detection



Similar documents
Single-Cell Whole Genome Sequencing on the C1 System: a Performance Evaluation

SEQUENCING. From Sample to Sequence-Ready

FCAP Array v3.0 Software: A New Tool to Analyze BD Cytometric Bead Array (CBA) Data. Monisha Sundarrajan, PhD BD Biosciences

Using CyTOF Data with FlowJo Version Revised 2/3/14

Single-Cell DNA Sequencing with the C 1. Single-Cell Auto Prep System. Reveal hidden populations and genetic diversity within complex samples

Uses of Flow Cytometry

Multiple Myeloma and Colorectal Cancer

Cell Discovery 360: Explore more possibilities.

How To Get A Cell Print

Introduction to flow cytometry

ArC Amine Reactive Compensation Bead Kit

Standardization, Calibration and Quality Control

APPLICATION INFORMATION

Introduction to Flow Cytometry

A Novel Bioconjugation Technology

Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy.

KMS-Specialist & Customized Biosimilar Service

Cytell Cell Imaging System

ab Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis

DELPHI 27 V 2016 CYTOMETRY STRATEGIES IN THE DIAGNOSIS OF HEMATOLOGICAL DISEASES

ELITE Custom Antibody Services

Introduction To Real Time Quantitative PCR (qpcr)

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer

Immunophenotyping peripheral blood cells

ab Protein Sumoylation Assay Ultra Kit

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

Deep profiling of multitube flow cytometry data Supplemental information

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

International Beryllium Conference, Montreal, Canada March 10, 2005

FULLY AUTOMATED PARALLEL DUAL STAINING DETECTION SYSTEM. ChromoPlex 1 Dual Detection for BOND

Introduction to Flow Cytometry

Signaling monitoring and flow cytometry

Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

Notes on titering antibodies

use. 3,5 Apoptosis Viability Titration Assays

Web-Based Analysis and Publication of Flow Cytometry Experiments

PROTOCOL. Immunostaining for Flow Cytometry. Background. Materials and equipment required.

Cell Cycle Phase Determination Kit

Application Note. Selecting Reagents for Multicolor Flow Cytometry. Holden Maecker and Joe Trotter BD Biosciences, San Jose

LIVE/DEAD Fixable Dead Cell Stain Kits

BBSRC TECHNOLOGY STRATEGY: TECHNOLOGIES NEEDED BY RESEARCH KNOWLEDGE PROVIDERS

Automating Cell Biology Annual general meeting, September 7, Phase Holographic Imaging

Automated Quadratic Characterization of Flow Cytometer Instrument Sensitivity (flowqb Package: Introductory Processing Using Data NIH))

RPCI 004 v.002 Staining Procedure For all Directly Conjugated Reagents (Whole Blood Method)

Manufacturing CUSTOM CHEMICALS AND SERVICES, SUPPORTING SCIENTIFIC ADVANCES FOR HUMAN HEALTH

Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T

2) Macrophages function to engulf and present antigen to other immune cells.

ab FITC Conjugation Kit Protocol

> Semantic Web Use Cases and Case Studies

Reconsideration Code Reconsideration Code Description Nuclear Matrix Protein 22 (NMP22), qualitative

Identification of rheumatoid arthritis and osteoarthritis patients by transcriptome-based rule set generation

Support Program for Improving Graduate School Education Advanced Education Program for Integrated Clinical, Basic and Social Medicine

exactly. The need for efficiency in developing effective new therapeutics has never been greater.

Designing Assays for the TaqMan Protein Assay

Preparation "Clinical Laboratory Technologist and Technician Overview"

Too Many B Cells: Chronic Lymphocytic Leukemia and the Role of Flow Cytometry

Custom Antibody Services

Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer

Annexin V-EGFP Apoptosis Detection Kit

HuCAL Custom Monoclonal Antibodies

Medical Device Solutions. Battelle. Applied Research Device Development Clinical Research Sustaining Engineering

OpenMedicine Foundation (OMF)

Analysis of the adaptive immune response to West Nile virus

SNPbrowser Software v3.5

ab StayBlue/AP Plus Stain Kit Instructions for Use An immunohistochemical chromogen substrate for staining tissue sections

Three Rules for Compensation Controls

Supplemental Information. McBrayer et al. Supplemental Data

123count ebeads Catalog Number: Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.

The National Centre for Biomedical Engineering Science

a measurable difference

Superior TrueMAB TM monoclonal antibodies for the recognition of proteins native epitopes

Flow cytometric analysis of stem cells derived from umbilical cord blood CD34+/CD45+ enumeration and viability

CONTENT. Chapter 1 Review of Literature. List of figures. List of tables

If you were diagnosed with cancer today, what would your chances of survival be?

Principles of Flowcytometry

Automation of Cell Staining Technical Information Bulletin

ProteinPilot Report for ProteinPilot Software

THE His Tag Antibody, mab, Mouse

Annexin V-FITC Apoptosis Detection Kit

COMPENSATION MIT Flow Cytometry Core Facility

AST Transplantation and Immunology Research Network (TIRN) 2016 Allied Health Professional Research Grant

LOAD & GO and make flow cytometry simplicity itself. the full spectrum of Flow Cytometry

TruSeq Custom Amplicon v1.5

Analyzing Samples for CD34 Enumeration Using the BD Stem Cell Enumeration Kit

Essentials of Real Time PCR. About Sequence Detection Chemistries

Multicolor Bead Flow Cytometry Standardization Heba Degheidy MD, PhD, QCYM DB/OSEL/CDRH/FDA Manager of MCM Flow Cytometry Facility

MEASURABLE PARAMETERS: Flow cytometers are capable of measuring a variety of cellular characteristics such as:

University of Medicine and Dentistry of New Jersey (UMDNJ)

Stem Cells Market Trends based on Primary Industry Analysis

RT 2 Profiler PCR Array: Web-Based Data Analysis Tutorial

Compensation Controls Data Visualization Panel Development Gating Quantum Dots

a Beckman Coulter Life Sciences: White Paper

MI Software. Innovation with Integrity. High Performance Image Analysis and Publication Tools. Preclinical Imaging

Transcription:

CyTOF2 Mass cytometry system Unveil new cell types and function with high-parameter protein detection

DISCOVER MORE. IMAGINE MORE. MASS CYTOMETRY. THE FUTURE OF CYTOMETRY TODAY. Mass cytometry resolves multiple metal probes per cell with minimal signal overlap, maximizing the information obtained from a single sample. With over 120 detector channels and over 35 isotopic probes, mass cytometry provides researchers with an unparalleled ability to phenotypically and functionally profile cells from normal and diseased states. The Fluidigm line of reagents, instrumentation, and data analysis tools provides everything you need for novel discovery applications using mass cytometry, including: The state-of-the-art CyTOF 2 mass cytometer The Maxpar line of metal-conjugated probes, panel kits and labeling reagents High-dimensional analysis tools from Fluidigm Cytobank

CyTOF APPLICATIONS Powerful. Proven Research. Mass cytometry enables comprehensive profiling of cellular phenotype, signaling state, cytokine/ chemokine expression and viability. It has also been used in transformative high-dimensional studies in diverse disciplines including immunology, cancer research, stem cell biology and drug profiling. Recent examples from the published literature include: 10 4 10 3 10 2 10 1 Cytokine and surface profiling Simultaneous analysis of 34 phenotypic and functional markers defined a continuum of cells connecting naïve and memory CD8+ T cell subsets. Along the continuum, cells were functionally distinguishable based on the unique array of cytokines they express, allowing for an unappreciated flexibility in orchestrating pathogen responses. 0 0 10 1 10 2 10 3 10 4 Deep phenotypic and functional profiling of CD8+ T cells Newell. E.W. et. al. Immunity 36, 142. Cell signaling Mass cytometry analysis provided a systemwide view of immune signaling responses of the human hematopoietic system. Analysis of the phenotyping-signaling 31-marker panel for 24 treatment conditions provided simultaneous characterization of all major bone marrow subsets, against which drug action and disease can be compared for mechanistic studies and pharmacologic intervention. Comprehensive analysis of hematopoietic system signaling responses Bendall SC, Simonds EF, et. al. Science 332, 687

CyTOF 2 Discover more per sample. The CyTOF 2 mass cytometer simultaneously resolves multiple parameters with minimal signal overlap, providing unprecedented insights into the functional and phenotypic complexity of biological systems at the single-cell level. The CyTOF 2 analyzes cells labeled with a panel of reagents conjugated to stable metal isotopes using cutting-edge time-of-flight mass cytometry technology. With over 120 detection channels and 35 Maxpar metal probes, CyTOF 2 simplifies panel design and unlocks the biological complexity inherent in cellular heterogeneity.

MAXPAR REAGENTS Simply more. Fluidigm offers a full line of reagents for high dimensional panel design, including metal-conjugated antibodies, application specific panel kits, as well as reagents for custom antibody labeling and nucleic acid staining. Maxpar metal-conjugated antibodies Fluidigm offers a large selection of Maxpar metal conjugated antibodies. Pre-conjugated and quality controlled for optimal experimental results Wide selection of human and mouse targets to cover a variety of applications Antibodies are sourced from the most reliable antibody vendors Maxpar Panel Kits Getting started with mass cytometry is now easier than ever. Maxpar Panel Kits provide all the necessary reagents for profiling human and mouse systems by mass cytometry. The kits contain: Sample prep staining buffers and detailed protocol optimized for mass cytometry Nucleic acid intercalator for cell identification A panel of up to 17 pre-titrated metal-conjugated phenotypic antibodies, which can be combined with additional Maxpar antibodies to deeply profile your system of interest Maxpar Metal Labeling Kits Maxpar labeling kits for over 35 different metals are available from Fluidigm for conjugating metals to antibodies or intracellular proteins. The labeling kits utilize a traditional approach of adding a metal polymer tag to the Fc region of the antibody using a maleimide linker and disulfide reduction chemistry. Nucleic Acid Intercalators Fluidigm provides two nucleic acid intercalators, one containing natural-abundance Iridium and the other containing 103Rh, for live-dead discrimination and cell identification in routine mass cytometry.

DATA ANALYSIS Powerful analysis options. Mass cytometry experiments routinely measure dozens of functional and phenotypic parameters in millions of single cells, output as.txt and.fcs files. Analysis of such high-dimensional datasets is performed using a tool kit that includes not only traditional histograms and bivariate plots, but also novel clustering algorithms, neural networks, and dimensionality reduction methods. Fluidigm has partnered with Cytobank to provide Fluidigm Cytobank, a cloud-based platform that offers an extensive suite of powerful tools for analysis of mass cytometry data, including: Bivariate plot The SPADE clustering algorithm for highdimensional panel analysis Histograms, bivariate plots, gating tools and statistics for traditional cytometric analysis Heat maps and dose response curves for comprehensive summarization of experimental data Intuitive management of files and analysis results, with secure storage and backup SPADE Web-based tools for sharing data and analysis with collaborators Heat map

CORPORATE HEADQUARTERS 7000 Shoreline Court, Suite 100 South San Francisco, CA 94080 USA Toll-free: 866 359 4354 Fax: 650 871 7152 fluidigm.com SALES North America: +1 650 266 6170 info-us@fluidigm.com Europe/EMEA: +33 (0)1 60 92 42 40 info-europe@fluidigm.com Japan: +81 (0)3 3662 2150 info-japan@fluidigm.com China (excluding Hong Kong): +86 (0)21 3255 8368 info-china@fluidigm.com Asia: +1 650 266 6170 info-asia@fluidigm.com Latin America: +1 650 266 6170 info-latinamerica@fluidigm.com 2014 Fluidigm Corporation. All rights reserved. Fluidigm, the Fluidigm logo, CyTOF, and Maxpar are trademarks or registered trademarks of Fluidigm Corporation in the U.S. and/or other countries. All other trademarks are the property of their respective owners. PN 100-7874 B1 For Research Use Only. Not for use in diagnostic procedures.