Geotechnic Parameters Analysis Obtained by Pencel Presuremeter Test on Clayey Soils in Resistencia City



Similar documents
c. Borehole Shear Test (BST): BST is performed according to the instructions published by Handy Geotechnical Instruments, Inc.

SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT

Soil behaviour type from the CPT: an update

Site Investigation. Some unsung heroes of Civil Engineering. buried right under your feet. 4. Need good knowledge of the soil conditions

Cone Penetration Testing in Geotechnical Practice. Tom Lunne Peter K. Robertson John J.M. Powell

NUMERICAL MODELLING OF PIEZOCONE PENETRATION IN CLAY

ON THE INTERPRETATION OF SEISMIC CONE PENETRATION TEST (SCPT) RESULTS

CONE PENETRATION TESTING AND SITE EXPLORATION IN EVALUATING THE LIQUEFACTION RESISTANCE OF SANDS AND SILTY SANDS ABSTRACT

Cone Penetration Testing (CPT) Michael Bailey, P.G. U.S. Army Corps of Engineers, Savannah District

Numerical Simulation of CPT Tip Resistance in Layered Soil

Ingeniería y Georiesgos Ingeniería Geotécnica Car 19 a Nº of 204 ; TEL : igr@ingeoriesgos.com

Soil Classification Through Penetration Tests

Eurocode 7 - Geotechnical design - Part 2 Ground investigation and testing

NOTES on the CONE PENETROMETER TEST

A case study of large screw pile groups behaviour

HAULBOWLINE, CORK STATIC CONE PENETRATION TESTS FACTUAL REPORT

A Ground Improvement Update from TerraSystems

International Journal of Scientific & Engineering Research, Volume 4, Issue 9, September ISSN

Module 1 : Site Exploration and Geotechnical Investigation. Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives

CHAPTER 1 INTRODUCTION

PREDICTING THE HYDRAULIC CONDUCTIVITY OF MAKASSAR MARINE CLAY USING FIELD PENETRATION TEST (CPTU) RESULTS

An Automatic Kunzelstab Penetration Test

ASSESSMENT OF SHEAR WAVE VELOCITY FROM INDIRECT INSITU TESTS

Improvement in physical properties for ground treated with rapid impact compaction

Anirudhan I.V. Geotechnical Solutions, Chennai

Measurement of Soil Parameters by Using Penetrometer Needle Apparatus

Penetration rate effects on cone resistance measured in a calibration chamber

By D. P. StewarP and M. F. Randolph z

Fundamentals of CONE PENETROMETER TEST (CPT) SOUNDINGS. J. David Rogers, Ph.D., P.E., R.G.

product manual HS-4210 HS-4210_MAN_09.08 Digital Static Cone Penetrometer

Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur

How To Design A Foundation

Using Combination of SPT, DMT and CPT to Estimate Geotechnical Model for a Special Project in Turkey

BEARING CAPACITY AND SETTLEMENT RESPONSE OF RAFT FOUNDATION ON SAND USING STANDARD PENETRATION TEST METHOD

APPENDIX A PRESSUREMETER TEST INTERPRETATION

SUGGESTION ABOUT DETERMINATION OF THE BEARING CAPACITY OF PILES ON THE BASIS OF CPT SOUNDING TESTS

Geotechnical Testing Methods II

CIVL451. Soil Exploration and Characterization

Standard Test Method for Mechanical Cone Penetration Tests of Soil 1

Numerical Analysis of Texas Cone Penetration Test

Characterization of an Artificially Prepared Cohesive Soil Bed

Statistical identification of homogeneous soil units for Venice lagoon soils

Penetrometer testing in residual soils from granitic rocks in the South of Portugal

Equivalent CPT Method for Calculating Shallow Foundation Settlements in the Piedmont Residual Soils Based on the DMT Constrained Modulus Approach.

Step 11 Static Load Testing

Effect of drainage conditions on cone penetration testing in silty soils

CPTic_CSM8. A spreadsheet tool for identifying soil types and layering from CPTU data using the I c method. USER S MANUAL. J. A.

CPT interpretation in marine soils less than 5m depth examples from the North Sea

TECHNICAL REPORT ON SCALA DYNAMIC CONE PENETROMETER IRREGULARITY

USE OF CONE PENETRATION TEST IN PILE DESIGN

Correlation of Standard and Cone Penetration Tests for Sandy and Silty Sand to Sandy Silt Soil

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 3, 2013

DYNAMIC CONE PENETRATION TEST INSTRUCTIONAL MANUAL GEOTECHANICAL

Instrumentations, Pile Group Load Testing, and Data Analysis Part II: Design & Analysis of Lateral Load Test. Murad Abu-Farsakh, Ph.D., P.E.

Multiple parameters with one Cone Penetration Test. by Mark Woollard

QUESTION TO AUDIENCE

Finite Element Modelling of Penetration Tests into Martian analogue Materials 27 June 1 July 2005, Anavyssos, Attica, Greece

Design of pile foundations following Eurocode 7-Section 7

Cone penetration testing, CPTu

Cone Penetration Test (CPT)

Subsoil investigation using integrated methods at Lagos, Nigeria

STABILITY ANALYSIS OF AN EARTH DAM FOUNDATION IN TUNISIA

2009 Japan-Russia Energy and Environment Dialogue in Niigata S2-6 TANAKA ERINA

CPTs EXECUTED IN DIFFICULT CONDITIONS USING CPTWD (CONE PENETRATION TEST WHILE DRILLING) AND ITS FUTURE DEVELOPMENTS

ODOT/OSU collaboration on the development of CPT Capabilities for use in Ohio Transportation Projects

A study on the Effect of Distorted Sampler Shoe on Standard Penetration Test Result in Cohesionless soil

Use of the Cone Penetration Test for Geotechnical Site Characterization in Clay-Mantled Karst. T. C. Siegel 1 and P. E. Cargill 2

COMPARISON OF THE CONE PENETRATION RESISTANCE OBTAINED IN STATIC AND DYNAMIC FIELD TESTS

Use and Application of Piezocone Penetration Testing in Presumpscot Formation

CARLOS FERNANDEZ TADEO & ASOCIADOS, S.L. Range of Services

Toe Bearing Capacity of Piles from Cone Penetration Test (CPT) Data

How To Prepare A Geotechnical Study For A Trunk Sewer Project In Lincoln, Nebraska

Determination of undrained shear strength parameters for buried pipeline stability in deltaic soft clays

Ground improvement using the vibro-stone column technique

EVALUATION OF TEXAS CONE PENETROMETER TEST TO PREDICT UNDRAINED SHEAR STRENGTH OF CLAYS HARIHARAN VASUDEVAN

Geotechnical Standards Eurocodes. An update

CIV SITE INVESTIGATION AND EXPLORATION TABLE OF CONTENTS

System. Stability. Security. Integrity. 150 Helical Anchor

CPTWD (Cone Penetration Test While Drilling) a new method for deep geotechnical surveys

INTERPRETATION OF CONE PENETRATION TESTS IN COHESIVE SOILS

GUIDE TO CONE PENETRATION TESTING

TECHNICAL Summary. TRB Subject Code:62-7 Soil Foundation Subgrades February 2003 Publication No.: FHWA/IN/JTRP-2002/30, SPR-2362

EVALUATION OF BEARING CAPACITY OF PILES FROM CONE PENETRATION TEST DATA

King Saud University College of Engineering Civil Engineering Department DEFORMATION OF PARTIALLY SATURATED SAND. Sultan Musaed Al-Ghamdi

Caltrans Geotechnical Manual

Optimised Design for Soil Nailed Walls 1

Module5: Site investigation using in situ testing

How To Model A Shallow Foundation

Using Miniature Cone Penetration Test (Mini-CPT) to determine engineering properties of sandy soils

Assessment of stress history in glacial soils on the basis of cone penetration tests

ENCE 4610 Foundation Analysis and Design

Soil Behavior Type using the DMT

ABSTRACT 2. TAILINGS TYPES AND TESTS 1. INTRODUCTION. the Ball Penetration Test (BPT) and the Field Vane Test (FVT).

CHAPTER 9 SOIL EXPLORATION 9.1 INTRODUCTION

How To Use The Static Cone Penetration Test

Instrumented Becker Penetration Test for Liquefaction Assessment in Gravelly Soils

Effect of grain size, gradation and relative density on shear strength and dynamic cone penetration index of Mahi, Sabarmati and Vatrak Sand

Ground water monitoring with the BAT-system

INSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:!

CEEN Geotechnical Engineering Laboratory Session 7 - Direct Shear and Unconfined Compression Tests

Transcription:

American Journal of Science and Technology 2015; 2(5): 237-242 Published online August 10, 2015 (http://www.aascit.org/journal/ajst) ISSN: 2375-3846 Geotechnic Parameters Analysis Obtained by Pencel Presuremeter Test on Clayey Soils in Resistencia City Dante René Bosch, Rubén Rafael Sotelo, Ricardo Daniel Caballero, Orlando Moran Applied Geosciences Centre, Faculty of Engineering, National Northeastern University (UNNE), Resistencia, Chaco, Argentina Keywords Pressuremeter, Pencel, Clay, CPT, Received: July 14, 2015 Revised: July 27, 2015 Accepted: July 28, 2015 Email address danterbosch@gmail.com (D. R. Bosch) Citation Dante René Bosch, Rubén Rafael Sotelo, Ricardo Daniel Caballero, Orlando Moran. Geotechnic Parameters Analysis Obtained by Pencel Presuremeter Test on Clayey Soils in Resistencia City. American Journal of Science and Technology. Vol. 2, No. 5, 2015, pp. 237-242. Abstract The Resistencia city has characteristic geomorphological environments of river valleys, mainly due to the influence of the Parana River and its tributaries. In many areas there is high heterogeneity of geotechnical profiles, sedimentary clayey, silt and sand soils, and water table near the ground surface. This brings many problems for designing and construction of engineering works, including low soil bearing capacity for the project of foundations and higher construction costs. To analyze the behavior under load of these soils, geotechnical engineering practice in the region commonly used field tests like the standard penetration test (SPT) and the cone penetration test (CPT). In order to improve the quality of the studies being conducted in the area, it is analyzed in this study the use of the pencel pressuremeter test (), which allows a stress-strain curve of soil in situ. It has been considered to use this test because the equipment and the test procedure are relatively inexpensive to incorporate into engineering practice. As the use of this type of pressuremeter test is relatively recent, this study has the objective to validate their results by comparing them with correlations available in the literature between CPT and traditional pressuremeter tests. The results indicate that the geotechnical parameters obtained through pencel pressuremeter test are consistent with the correlations available in the international literature. Although the universe of data analyzed is small and should be extended, preliminary results are favorable on the potential use of the pencel pressuremeter test for geotechnical studies in the region. 1. Background Metropolitan area of Great Resistencia has characteristic geomorphologic environment of river valleys, due mainly to the influence of Paraná River and its tributaries (Popolizio, 1986). In many areas there is high heterogeneity profiles, sedimentary clayey, silt and sand soils, and water table near the ground surface. This brings many problems for designing and construction of engineering works, including low soil bearing capacity for the project of foundations and higher construction costs. Upper strata are mainly clayey soils whose consistency varies from soft to very compact according the formation and history of tensions (Bosch et al 2008). Consequently, parameters that describe their stress-strain behaviour acquire primary importance for foundation projects of civil engineering works.

238 Dante René Bosch et al.: Geotechnic Parameters Analysis Obtained by Pencel Presuremeter Test on Clayey Soils in Resistencia City To determine these parameters local geotechnical engineering practice employs field test like Standard Penetration Test (SPT). In the past decade it was also used frequently for field tests the cone penetration test (CPT), which consists of driving a tip with electronic load cells allowing to estimate the resistance that the soil offers to penetration (Lunne et al, 1997). The most common practice consists of correlate directly results of SPT and CPT tests with geotechnical parameters of strength and deformation. There exists countless correlations, many of them international, which allow to estimate parameters of geotechnical behavior from the before mentioned tests (Lunne et al, 1997; Briaud, 1992). Considering that both the SPT and the CPT test performed measurements of soil resistance and no deformation under load, correlations available in the international literature related deformation parameters (Young's modulus for example) are less reliable. As every correlation present certain dispersión of results, it is common in practice to use conservatively lower limits of such correlations. As a result, many times the bearing capacity obtained are lower than that would be obtained if intermediate values were adopted in dispersion of values, a situation that is considered could be possible in many cases if there were geotechnical methods more reliable and economically applicable (Sotelo & Bosch, 2001). Although present situation could not seem a major problem because building seem to be safer, many times this situation forces to adopt deep foundations instead shallow foundations, becoming them significantly more expensive. In real estate projects this results in a higher final price of the property which has even caused the unviability of many projects in the area. As an alternative to improve this problem, the use of the pencel pressuremeter test is used in this work which consists of introducing a cylindrical probe into the soil which is then is radially expanded by water injection (Roctest Inc., 2005). It has been considered to employ this test because of the equipment and the test procedure are relatively low cost to be incorporated to the routine practice in geotechnical studies in the zone. During the expansion process of the cylinder probe applied pressure and radial deformations were registered, allowing to obtain a stress-strain curve in the field from which rupture and deformation parameters of soil can be obtained using formulations of a cylindrical expansion of a cavity (Mair & Wood, 1987). As the use of this type pressuremeter test is relatively recent, this work has the objective to validate its results comparing them with existing correlations in literature between the CPT and traditional pressuremeter tests. 2. The Pencel Pressuremeter Test The pencel pressuremeter test () was developed by Menard (Menard, 1956), from which arose different equipment up to the present. The pencel pressuremeter test is relatively new. It has a probe diameter of 1,35 inches which is connected to a pressure and volume control unit by means a plastic tube as shown in Figure 1. The probe is pushed into the soil statically or dynamically until it reaches the desired depth. The rotation of a handle by the operator moves a piston placed into the control unit which injects water through the system that produces a volume change in the probe and thus pressure may be measured. Before performing the test it is necessary to make two calibrations, one to measure resistance to the membrane and the other to determine expansion of system under pressure. Besides, a correction for the pressure is applied as a result of the hydraulic pressure generated by the depth in which the test is placed. The standard test is of controlled deformation, where the operator injects 5 cm 3 of water, waits for 30 seconds and registers the pressure that offers the soil to expansion. Then the process is repeated until maximum deformation of the equipment is reached. Alternatively, cycles of load and reload may be made during the process. Figure 1. The pencel pressuremeter test. (Roctest Inc., 2005). Once obtained data, corresponding corrections to stiffness of membrane are made, also to expansion of system out of the probe and to the initial hydraulic pressure. Figure 2 shows a typical result where the phases of elastic, plastic a load-reload behavior are observed. From this information the Pressuremeter Modulus (Eo), the Pressuremeter Rebound Modulus (Er) and the Limit Pressure (pl) are determined.

American Journal of Science and Technology 2015; 2(5): 237-242 239 3. The Cpt Correlations with Pressuremeter Test Figure 2. Geotechnical parameters obtained from corrected curve. (Roctest Inc., 2005). For determining Pressuremeter Modules, it will be used: P E = 2*(1 + ν ) *( Vo + Vm) * V Where ν: Poisson s ratio Vo: Initial Volume Vm: Average Volume P: Change in Pressure V: Change in Volume The cone penetration test CPT consists of driving a tip with electrically instrumented load cells allows the meassurement of the cone tip resistance (qc) and sleeve friction resistance (fs). The equipment used in the zone has a pushing unit with hydraulic pistons which guarantee a static driving to a standardized velocity, a system of reaction that attaches the equipment to the soil with helical anchorages, bars and a cone tip standardized according ASTM D3441-86 and acquisition data system that registers electronically and with great sensitivity the tip resistance and the sleeve friction. Resistance registers are made every 10 cm deep or less, obtaining a great detail of soil stratigraphy. Figure 3 presents a typical result of the CPT test (Meigh, 1987). One of the great advantages of this field test is its automation that makes it low sensitive to problems related to sample alterations or human errors during its performance. For this reason international correlations with other tests are reliable enough to extrapolate results. Table 1 shows correlations between the CPT and the Pressuremeter Test (PMT) (Briaud, 1992). Figure 3. Typical result of the CPT in study area.

240 Dante René Bosch et al.: Geotechnic Parameters Analysis Obtained by Pencel Presuremeter Test on Clayey Soils in Resistencia City Table 1. Correlation between PMT and CPT (Briaud, 1992). Soil Type PMT Parameter Correlation to CPT Clay Pl 0.20 qc Eo 2.50 qc Er 13.00 qc Sand Pl 0.11 qc Eo 1.15 qc Er 6.25 qc 4. Materials Y Methods indicated in Table 2. Also, relation between geotechnical parameters obtained and cone tip resistance in the CPT are presented here. In Figures 5, 6 and 7 are graphed relationship between parameters obtained in the (pl, Eo y Er) with cone tip resistance in the CPT. 0,0 qc (Kpa) 0 2000 4000 6000 This work has the objective to validate results obtained with the pencel pressuremeter test () in clayey soils in the Resistencia City. As a method of validation it has been adopted the criterion of comparing results obtained in this test with existing correlations in literature between traditional pressuremeter and CPT. The study place selected has clayey soils in the upper layer, very common in the city of Resistencia (Bosch et al, 2008). In this site three standard penetration tests (SPT), three cone penetration tests (CPT) and six pencel pressuremeter tests () were performed. The tests were made to 1,00 y 1,50 meter depth, which correlate to shallow foundation levels normally adopted in the engineering practice of the zone. 5. Results Obtained Depth (m) 0,5 1,0 1,5 Results of the SPT and CPT indicate that the study place is characterized for presenting in surface and approximately 2,50 m depth a silty clay stratum that classifies as CL in the Unified Soil Classification System (U.S.C.S.). This soil has an average SPT N value of 10 and approximately 3.000 tip resistance in the CPT. Afterwards, and up to 5,00 meters depth approximately there are silty soils that classify as ML in the U.S.C.S. From there and up to 10 meters depth there are silt sands that classify as SM in the U.S.C.S. Figure 4 shows cone tip resistance in the CPT tests at the interest depth for this analysis. Results obtained by pencel pressuremeter tests are 2,0 2,5 3,0 Figure 4. Cone tip resistance. CPT tests. Depth m pl Table 2. Results of tests and relationship with CPT. Eo Er qc pl/qc Eo/qc Er/qc 1 1.5 420 5801 30301 2717 0.15 2.14 11.2 2 1.0 376 6413 29261 2550 0.15 2.51 11.5 3 1.5 566 5219 50578 3900 0.15 1.34 13.0 4 1.0 568 7757 51820 3006 0.19 2.58 17.2 5 1.5 789 8614 55724 4257 0.19 2.02 13.1 6 1.0 582 6435 34561 3425 0.17 1.88 10.1 Average values 0.17 2.08 12.67

American Journal of Science and Technology 2015; 2(5): 237-242 241 0.20 0.18 0.16 0.14 pl / qc average value = 0.16 0.12 pl/qc 0.10 0.08 0.06 0.04 0.02 0.00 0 1 2 3 4 5 6 7 Figure 5. Relationship between limit pressure (pl) and cone tip resistance (qc). 3.00 2.50 2.00 Eo / qc average value = 2.14 Eo / qc 1.50 1.00 0.50 0.00 0 1 2 3 4 5 6 7 Figure 6. Relationship between pressuremeter modulus (Eo) and cone tip resistance (qc). 20.0 18.0 16.0 14.0 Er / qc 12.0 10.0 8.0 Er / qc average value = 12.70 6.0 4.0 2.0 0.0 0 1 2 3 4 5 6 7 Figure 7. Relationship between pressuremeter rebound modulus (Er) and cone tip resistance (qc).

242 Dante René Bosch et al.: Geotechnic Parameters Analysis Obtained by Pencel Presuremeter Test on Clayey Soils in Resistencia City As it may be observed in Table 2 and in Figures 5 to 7, relationship pl/qc varies from 0,15 to 0,19, with an average value of 0,17. For relationship Eo/qc values between 1,34 and 2,58 were obtained with an average of 2,08. Regarding relationship Er/qc value obtained vary between 10,10 y 17,20 and an average 12,67. Although exists certain dispersion in the results, these values agree with proposed correlations by Briaud (1992) for traditional pressuremeter tests according presented in Table 1. Although data universe is small and should be enlarged, preliminary results are favorable regarding the potential use of pencel pressuremeter in routine geotechnical studies in the zone. 6. Conclusions In this work it has been considered employing the pencel pressuremeter test to improve routine geotechnical studies due to equipment and test procedures are relatively low cost so as to incorporate to the engineering practice in the zone. In cases analyzed a good agreement was found between geotechnical parameters obtained by means the pencel pressure meter tests and available correlations in literature between resistance of toe CPT and geotechnical parameters in traditional pressuremeter tests. Although universe of data is small and should be enlarged, preliminary results are favorable related to the potential use of the pressuremeter test for routine geotechnical studies in the zone. References [1] POPOLIZIO, E.; 1986, Influencia del sistema geomorfológico en las crecientes e inundaciones del Nordeste Argentino, Geociencias XIV, n.14, pp.3-33. Centro de Geociencias Aplicadas, UNNE. [2] BOSCH, DANTE RENÉ; SOTELO, RUBÉN RAFAEL. 2008. Caracterización geotécnica del Area Metropolita-na del Gran Resistencia: tipos de suelo. XIX Congreso Argentino de Mecánica de Suelos e Ingeniería Geotécnica. [3] ROBERTSON, P.K.; POWELL, J.J.M., 1997. Cone penetration testing in geotechnical practice. 1.ed. London: Blackie Academic & Profesional. 312p. [4] BRIAUD, J. L.1992. THE PRESSUREMETER. A.A. BALKEMA/ ROTTERDAM/ BROOKFIELD [5] SOTELO, R.R; BOSCH, D.R., 2001. Determinación del módulo de elasticidad no drenado en arcillas saturadas de la región oriental del Chaco. Comunicaciones Científicas. Ciencia y Técnica de la UNNE. [6] ROCTEST, INC, 2005. PENCEL Pressuremeter Instruction Manual, Plattsburgh, N.Y.: Roctest, Inc. [7] MAIR, R.J.; WOOD, D.M.,1987. Pressuremeter Testing. Methods and interpretation. Butterworths. London. [8] MENARD, L. 1956. An Apparatus of Measuring the Strength of Soils in Place. Master s Thesis. University of Illinois, Illinois, USA. [9] MEIGH, A.C., 1987. Cone penetration testing: methods and interpretation. 1.ed. London: Butterworths. 141p. [10] AMERICAN SOCIETY FOR TESTING OF MATERIALS, 1987. Standard test method for cone penetration testing: D3441-86. Annual Book of ASTM Standards V.04.08. New York.