PURE TONE AUDIOMETER



Similar documents
HEARING MEASUREMENT 8.1. INTRODUCTION (RATIONALE FOR AUDIOMETRY)

PURE TONE AUDIOMETRY Andrew P. McGrath, AuD

COMPREHENSIVE MATLAB TOOL FOR HRTF MEASUREMENT AND VIRTUAL AUDITORY SPACE TESTING

Manual Pure-Tone Threshold Audiometry

1000+ AUDIOMETER OPERATING INSTRUCTIONS

SPEECH Biswajeet Sarangi, B.Sc.(Audiology & speech Language pathology)

Dr. Abdel Aziz Hussein Lecturer of Physiology Mansoura Faculty of Medicine

GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER. Setting The Clinical Standard

Testing FM Systems on the FP35 Hearing Aid Analyzer -1-

AUDIO POINTER V2 JOYSTICK & CAMERA IN MATLAB

Audiometry and Hearing Loss Examples

Instructions for the use of E-A-RTONE 3A. Insert Earphones. Revised 1997 per ANSI S and ISO 389-2: /99

Hearing Tests And Your Child

Recommended Procedure. Pure-tone air-conduction and bone-conduction threshold audiometry with and without masking

Convention Paper Presented at the 112th Convention 2002 May Munich, Germany

Hearing Screening Protocol for School Aged Children

MA 25 Operating Manual

Hearing Tests And Your Child

Early vs. Late Onset Hearing Loss: How Children Differ from Adults. Andrea Pittman, PhD Arizona State University

PROFESSIONAL BOARD FOR SPEECH, LANGUAGE AND HEARING PROFESSIONS STANDARDS OF PRACTICE IN AUDIOLOGY

AN-007 APPLICATION NOTE MEASURING MAXIMUM SUBWOOFER OUTPUT ACCORDING ANSI/CEA-2010 STANDARD INTRODUCTION CEA-2010 (ANSI) TEST PROCEDURE

Matlab GUI for WFB spectral analysis

DAILY BIOLOGIC CHECK OF AUDIOMETERS

Tonal Detection in Noise: An Auditory Neuroscience Insight

Guidelines for Manual Pure-Tone Threshold Audiometry

HEARING SCREENING (May 2006)

HEARING SCREENING FOR CHILDREN

Welcome to the United States Patent and TradeMark Office

GUIDELINES ON THE ACOUSTICS OF SOUND FIELD AUDIOMETRY IN CLINICAL AUDIOLOGICAL APPLICATIONS

The Accuracy of 0 db HL as an Assumption of Normal Hearing

FREQUENCY RESPONSE OF AN AUDIO AMPLIFIER

SPEECH INTELLIGIBILITY and Fire Alarm Voice Communication Systems

The NAL Percentage Loss of Hearing Scale

Operating Instructions MAICO MA 52

Pediatric Whitepaper. Electrophysiological Threshold Estimation and Infant Hearing Instrument Fitting

MATLAB-based Applications for Image Processing and Image Quality Assessment Part II: Experimental Results

Pure Tone Hearing Screening in Schools: Revised Notes on Main Video. IMPORTANT: A hearing screening does not diagnose a hearing loss.

Interference to Hearing Aids by Digital Mobile Telephones Operating in the 1800 MHz Band.

Practice Standards for Hearing Service Providers

Audio Examination. Place of Exam:

Main features * : Internal database > 1000 tests. Suprathreshold tests. High frequency. Musical frequencies. Automatic masking.

MA33 & MA55. PC Based Audiometers. The ideal choice for health care professionals on the go. by Maico Diagnostics

Air Conduction Audiometer Series. MA 27 with headphones and built-in carrying case. MA1, MA25 & MA27.

GSI AUDIOSTAR PRO. Free Call: CLINICAL TWO-CHANNEL AUDIOMETER. Australian Distributer:

What Audio Engineers Should Know About Human Sound Perception. Part 2. Binaural Effects and Spatial Hearing

Noise: Impact on Hearing; Regulation

OPEN ACCESS GUIDE TO AUDIOLOGY AND HEARING AIDS FOR OTOLARYNGOLOGISTS

By Michael Block, PhD

Using Your Fitting Software This guide provides comprehensive, task-based information about all the fitting software features.

REGULATIONS FOR THE DEGREE OF MASTER OF SCIENCE IN AUDIOLOGY (MSc[Audiology])

Tuning Subwoofers - Calibrating Subwoofers

5th Congress of Alps-Adria Acoustics Association NOISE-INDUCED HEARING LOSS

Auditory evoked response, clicks, notch noise bandwidth, frequency

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

Guideline for diagnosing occupational noise-induced hearing loss. Part 3: Audiometric standards

Noise. CIH Review PDC March 2012

3M E-A-RTONE 3A and 5A Audiometric Insert Earphones

Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds.

Your Hearing ILLUMINATED

HEARING SCREENING: PURE TONE AUDIOMETRY

Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

California State University, Fresno Department of Communicative Disorders and Deaf Studies CDDS 128. Observations in Audiology

CONVENTIONAL AND DIGITAL HEARING AIDS

Computer Networks and Internets, 5e Chapter 6 Information Sources and Signals. Introduction

ACOUSTICAL CONSIDERATIONS FOR EFFECTIVE EMERGENCY ALARM SYSTEMS IN AN INDUSTRIAL SETTING

Aircraft cabin noise synthesis for noise subjective analysis

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

Equinox 2.0 PC-based audiometer. Not just an audiometer - A full counseling and reporting solution

Product Line for Hearing Screening & Diagnostics

On frequency characteristics of bone conduction actuators by measuring loudness, acceleration and otoacoustic emission

Prescriptive Fitting Algorithms: New and Improved! Michelle Mattingly, Au.D. and Lisa Perhacs, Au.D.

The impact of using real ear measures to calculate prescriptive targets on hearing aid follow-up visits

UCSC HEARING CONSERVATION PROGRAM Environment, Health & Safety (EH&S) August 2007

Experiment #11: LRC Circuit (Power Amplifier, Voltage Sensor)

Understanding SWR by Example

Generic - Hearing Loop - (AFILS) U.S. System Specification

Effects of Noise Attenuation Devices on Screening Distortion Product Otoacoustic Emissions in Different Levels of Background Noise

A New Concept of PTP Vector Network Analyzer

Accessibility-MiVoice-Business.docx Page 1

Hearing Devices Policy and Administration Manual

INTERFERENCE OF SOUND WAVES

RF System Design and Analysis Software Enhances RF Architectural Planning

User's Guide. Digital Sound Level Meter. Model

UC Santa Barbara Hearing Conservation Program Manual

INTERFERENCE OF SOUND WAVES

IEC Algorithmic Alert Tone Demo

THE MYTHICAL X CURVE

Sound Pressure Measurement

Case Study THE IMPORTANCE OF ACCURATE BEHAVIOURAL TESTING IN INFANT HEARING AID FITTINGS

Functional Communication for Soft or Inaudible Voices: A New Paradigm

Understanding Hearing Loss

Trigonometric functions and sound

Transcription:

PURE TONE AUDIOMETER V. Vencovský, F. Rund Department of Radioelectronics, Faculty of Electrical Engineering, Czech Technical University in Prague, Czech Republic Abstract Estimation of pure tone hearing threshold is a part of hearing tests conducted in order to know the sensitivity of the human auditory system. This paper presents manual audiometer implemented in Matlab which can be used to conduct such measurements. Audiometer was calibrated by means of an artificial ear and pistonphone. Modified Hughson-Westlake method [1] usually used in manual audiometry is described. 1 Introduction Pure tone threshold audiogram is a graph of the lowest signal intensity as a function of signal frequency which can the person under test hear during certain measurement conditions. The level is usually drawn as the amount of deviation from the standard threshold value (for airconducted signals presented via earphones the threshold was published in ISO 389-8:2004 and ISO 389-5:2006 standard) and thus it is easily visible if the person s hearing is in normal range. Audiometer is the calibrated clinical device which is used for the audiogram measurement. This paper presents software version of audiometer developed in Matlab environment. The audiometer was developed in order to conduct hearing assessment tests of subjects who will serve in psychophysical hearing tests conducted for research purposes at the Department of Radioelectronics, CTU in Prague. 2 Audiometer 2.1 GUI and Implementation Graphical user interface of the Matlab audiometer is in the Fig. 1. This interface is controlled by a test conductor. It allows to choose the ear which is being investigated (hearing threshold is measured separately for each ear), set the pure tone frequency and level, play the sound signal, save the threshold values and save the final measured data to the file. Graphical user interface is very simple and it was not written in GUIDE. The main body is the function called audiometer.m. Calling the function without parameter builds the main audiometer GUI. Pressing the play button plays the sound signal via earphones. Duration of the pure tone is 2 seconds and it is generated by means of Matlab function sin. Onset and offset of the signal is ramped by 50 ms raised-cosine ramps. The signal is presented to the sound card by means of Matlab function sound. Sample frequency is 48 khz. The frequency and level of the signal can be set in the editable fields. Since it is convenient to quickly change the level values, two control elements (the button down and up) were placed under the level editable field. Pressing the button down and up will cause decrease and increase of the level by 5 db respectively. The value 5 db was chosen because it is the lowest step size which is used in the modified Hughson-Westlake method (see Fig. 3). The signal level is in db re absolute threshold values according to ISO 389-8:2004 and ISO 389-5:2006 standard. Audiogram will thus show deviations in db from normal hearing sensitivity to pure tones.

Figure 1: Graphical user interface of the pure tone audiometer The save button will store the currently measured value of threshold. It is visualized for the right and left ear as a cross and circle mark in the graph respectively. After the measurement is done, all values can be saved to the file by pressing the button save all. 2.2 Calibration Measurement system consists of a computer with Matlab, sound card and earphones. It is necessary to know the amplitude transfer characteristics of earphones and to know the sound pressure level of signal entering the ear. Calibration of the earphones can be done by means of an artificial ear. Microphone of the artificial ear can be calibrated by pistonphone. Authors of this paper used sweep sine tone generated in Matlab (function chirp) for the earphones calibration. This signal was played via earphones and recorded to Matlab. Microphone of the artificial ear was then connected to pistonphone which generates the known value of sound pressure level at the microphone membrane. The output signal of microphone was again recorded to Matlab. Sound pressure level of the signal generated by the earphones can be easily calculated by this relationship L earphones = L p 20 log(a p /A earphones ), (1) where L p is the known sound pressure level of pistonphone, A p is the amplitude of pistonphone signal recorded to Matlab and A earphones is the amplitude of earphones signal recorded to Matlab. This amplitude is generally frequency dependent (see calibration curve in the Fig.2). It is supposed that the recorded signals (both the pistonphone and earphones) were measured with the same setting of a microphone amplifier and sound card mixer. If the amplifier sensitivity was changed, the corresponding values of amplitudes in Eq. 1 must be scaled. Since we know the parameters of input sweep signal used for the earphones calibration and the values of sound pressure level as a function of signal frequency, we know how to generate a pure tone signal in Matlab which will cause desired sound pressure level at the earphones output. This is essential for the proper function of the audiometer.

60 55 50 amplitude (db SPL) 45 40 35 30 25 20 15 100 1000 10000 frequency (Hz) Figure 2: Calibration curve of the left earphone Sennheiser HD 280 Pro. 3 Audiogram measurement 3.1 Modified Hughson-Westlake method This section explains methods of audiogram measurement. The procedure description was taken from the source [1] and [2]. Different procedures can be used to obtain an audiogram. Three basic groups of procedures are the method of constant stimuli, method of adjustment and method of limits. In the method of constant stimuli the series of tones of certain frequency and level is presented to the listener who s task is to respond if he perceives the signal. If the number of responses is equal to half of the signal presentations, the signal level is set as threshold. This method is the most accurate but also the most time consuming In the method of adjustment, the listener can control level of the signal and is instructed to set it to the just-barely heard value. If it were set to lower level, the listener would not be able to hear it at all. This just-barely heard value is taken as threshold. This method is the most inaccurate and least time consuming. In the method of limits, the signal of certain frequency and level is presented to the listener and his response is recorded. The signal level is changed and the response is again recorded. The threshold is the lowest level where the response was at least in 50 % of the presentations. Since the accuracy of this method somewhere in the middle between the accuracy of two other methods and it is less time consuming then the method of constant stimuli, it is suitable for manual audiometry. There are various versions of the method of limits. The mostly used procedure which will be explained here is the modified Hughson-Westlake method [1]. Flow chart of the method is in the Fig. 3. First, the signal of certain frequency is presented to the subject with clearly perceived level. In case of normal hearing it should be 40 db above standard threshold. Subject is instructed to respond if he perceives the signal. The value of signal level is then decreased by 15 db after each response until he stops responding. The level is then increased by 5 until the listener starts to respond again and then again decreased by 10 db when when he stops responding. The threshold is the signal level for which the listener responds two out of three times after the level started to be incremented.

Figure 3: Modified Hughson-Westlake flow chart (adapted from [2]). Testing for clinical purposes is done for octave frequencies from 125 Hz to 8 khz. Halfoctave frequencies 750 Hz, 1.5 khz, 3 khz and 6 khz can be included too. As it was mentioned above, testing is done for each ear separately. It is convenient to start with better ear. If the better ear is not known, then the right ear is the default starting ear. The recommendation is to start with the 1 khz tone and then measure lower frequencies. After the measurement of lower frequencies is done, set the frequency again to 1 khz and measure the threshold again. If the both thresholds for 1 khz agree within 5 db, testing can continue for higher frequencies. If not, it is necessary to stop testing, re-fit the earphones and re-instruct the listener. The same sequence of testing frequencies should be used for the worse (left) ear. It is just not necessary to retest 1 khz frequency again because the listener already showed consistency in his answers for the better (right) ear. Normal hearing range is within 20 db re normal absolute threshold. 4 Conclusion Software version of pure tone manual audiometer was implemented in Matlab. It allows to estimate the hearing threshold for pure tones. The device was realized in order to conduct hearing tests on persons who are willing to serve as subjects in psychophysical hearing tests conducted at the Department of Radioelectronics, CTU in Prague. Calibration of the audiometer (Matlab implementation, sound card, earphones) was done by means of an artificial ear and pistonphone. Modified Hughson-Westlake method which is used during pure tone audiometry was described.

Acknowledgements This work was supported by the Grant Agency of the Czech Technical University in Prague, grant No. SGS11/159/OHK3/3T/13 References [1] R. Carhart and J. Jerger. Preferred Methods for Clinical Determination of Pure-Tone Thresholds. J. Speech Hear. Res., 24:330 345, 1959. [2] J.R. Franks. Hearing measurement. http://www.who.int/entity/occupational_health/ publications/noise8.pdf, Jun 2006. V. Vencovský Department of Radioelectronics, FEE, CTU in Prague, Technická 2, 166 27 Praha 6, Czech Republic, email: vencovac@fel.cvut.cz F. Rund Department of Radioelectronics, FEE, CTU in Prague, Technická 2, 166 27 Praha 6, Czech Republic, email: xrund@fel.cvut.cz