P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Dual wall sub-base fuel tanks-ibc Certified kw DGHCA/CB/CC/DA/DB (4BT3.3G5) DSFAA/B/C/D/E (QSB5G3) DSGAA/B/C/D/E (QSB7G5) DSHAA/B/C/D (QSL9G2)

Magnum Mobile Generator MMG55 Specifications

Explosion-Proof Electric Unit Heaters

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

ECOCIAT. Domestic hot water heat recovery unit

The kva RAnge

CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT kva / ekw

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

Element D Services Plumbing

FAIRBANKS NIJHUIS PACKAGED FIRE PUMP SYSTEMS.

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

DIESEL GENERATOR SETS

SECTION MORTUARY REFRIGERATORS

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Fire Pump Plan Review March 2010

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Commercial Gas Furnace Upflow

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

Decision-Maker Paralleling System. Power Distribution Switchboards and Circuit Breakers. Standard Features

HEAVY DUTY STORAGE GAS

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

2010 Residential Water Heater Replacement Check List

HP switch LP switch Discharge thermo Comp. Surface thermo

CADB and CADT-D / DI / DC Series

NFPA31FuelOilPiping 1 Revised

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

Name Of Occupancy Date. Yes No Describe

MAC-120HE-01 Air-Cooled Chiller

Cooling Capacity CFM in. w.c. (125 Pa)

FOXAIR 60/50 ALL MODELS

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

Cooling Capacity CFM in. w.c. (125 Pa)

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 10 kw 12.

Midwest Industrial Tanks

Sample - No Commercial Use

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

Building Permit Application

Diesel Engine Driven Generators Page 1 of 6

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

PAINT BOOTH LIGHTING

Cubetainer. The competition can t stack up to Snyder! Stackable Tanks, Stands and Containments

Cooling Capacity CFM in. w.c. (125 Pa)

Utility Distribution Systems

Split System Cooling Product Data

ASCO SERIES 185 Power Transfer Switches

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

DRYER VENTING SPECIFICATIONS DRYER SAFETY

Commercial Gas Water Heaters

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

COMMISSIONING OF HVAC SYSTEMS

PLAN REVIEW SERVICES CONSTRUCTION DOCUMENTS NECESSARY FOR A THOROUGH PLAN REVIEW

Advantium 2 Plus Alarm

Frequently Asked Questions Generators

Split System Heat Pump Product Data

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

USER S MANUAL HSC-24A

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

SECTION GENERAL PROVISIONS FOR HVAC WORK

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Installation Manual CLIFC Fan & Coil Variable Speed

Technical Specification. Generating Set with Waukesha engine burning natural gas

NSN

Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.

CITY OF FAIRFAX CODE ADMINISTRATION / FAX

Morrison Bros. Co. General Product Specifications

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

ARMSTRONG AIR HEAT PUMPS

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Installation Instructions for Alarm Module Kit A043F059

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Cooktop Low-Profile Ventilation Hoods

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

Transcription:

Industrial Generator Set Accessories Weather/Sound and Subbase Package Applicable to the following: 700-1000REOZDE 750-1000REOZMD Weather Standard Features D Internal-mounted, exhaust silencer with rain cap. D Lift base or tank-mounted, steel or aluminum construction with hinged and removable doors. Aluminum enclosures recommended for high humidity and/or high salt/coastal regions. D Fade-, scratch-, and corrosion-resistant Kohlerr Power Armort cream beige automotive-grade textured finish. D has six large access doors which allow for easy maintenance. D Lockable, flush-mounted door latches. D Air inlet louvers reduce rain and snow entry. D High wind bracing, 241 kph (150 mph). Weather (Shown with Lift Base) Sound (Shown with Subbase ) Available Approvals and Listings - UL 2200 Listing - CSA Approval - IBC Seismic Certification - California OSHPD Approval (750--1000REOZMD models only) - cul Listing (fuel tanks only) - Florida Dept. of Environmental Protection (FDEP) compliance Sound Standard Features D Includes all of the weather enclosure features with the addition of acoustic insulation material. D Louvered air inlet and vertical outlet hood with 90 degree angles to redirect air and reduce noise. D Acoustic insulation that meets UL 94 HF1 flammability classification. D Sound attenuated enclosure that offers an average of 75 db(a) sound level at 7 m (23 ft.) using acoustic insulation, acoustic-lined air inlets and an acoustic-lined air discharge. Subbase Features D The fuel tank has a Power Armor Plust textured epoxy-based rubberized coating. D The above-ground rectangular secondary containment tank mounts directly to the generator set, below the generator set skid (subbase). D Both the inner and outer tanks have UL-listed relief vents. D Flexible fuel lines are provided with subbase fuel tank selection. D The containment tank s construction protects against fuel leaks or ruptures. The inner (primary) tank is sealed inside the outer (secondary) tank. The outer tank contains the fuel if the inner tank leaks or ruptures. D The above ground secondary containment subbase fuel tank meets UL 142 requirements. G6-118 11/13d Page 1

Weather Air inlet louvers Automatic door holders provide positive door positions during wind gusts Enclosed exhaust silencer for improved safety and noise reduction Fade-, scratch-, and corrosion-resistant powder-baked finish Horizontal air discharge through a removable air outlet grille ADV-7630- Hinged and removable doors for ease of servicing Lockable, flushmounted door latches prevent tampering Oil drain and radiator drains Rodent guards and skid end caps prevent unwanted animal entry ships assembled on subbase fuel tank or lifting base. Weather Features D Available in steel (14 gauge) or aluminum (3 mm [0.125 in.]) formed panel, solid construction. Preassembled package offering corrosion resistant (aluminum), dent resilient structure mounting directly to lift base or fuel tank. D Power Armort automotive-grade finish resulting in advanced corrosion and abrasion protection as well as enhanced edge coverage and color retention. D Internal exhaust silencer. Offers maximum component life, operator safety, and includes rain shield and cap. NOTE: Installing an additional length of exhaust tail pipe may increase backpressure levels. Please refer to the generator set spec sheet for the maximum backpressure value. D Service access. Multi-personnel doors for easy access to generator set control and servicing of the fuel fill, fuel gauge, oil fill, and battery. D Cooling/Combustion Air Intake d Weather protective designs using fixed air inlet louvers. Sized for maximum cooling airflow. D Cooling Air Discharge d Weather protective design featuring horizontal air discharge. Exhausts air through a removable punched air outlet grille. G6-118 11/13d Page 2

Sound Louvered air openings at the generator end supply ample cooling air flow Automatic door holders provide positive door positions during wind gusts Enclosed insulated exhaust silencer for improved safety and noise reduction Fade-, scratch-, and corrosion-resistant powder-baked finish Vertical outlet hood with 90_ angles to redirect air and reduce noise ADV-7630- Hinged and removable doors for ease of servicing Lockable, flushmounted door latches prevent tampering Acoustic insulation repels moisture absorption Oil and radiator drains Acoustic insulation meetingul94hf1 flammability classification Rodent guards and skid end caps prevent unwanted animal entry ships assembled on subbase fuel tank or lifting base. Sound Features D Available in steel (14 gauge) or aluminum (3 mm [0.125 in.]) formed panel, solid construction. Preassembled package offering corrosion resistant (aluminum), dent resilient structure mounting directly to lift base or fuel tank. D Power Armort automotive-grade finish resulting in advanced corrosion and abrasion protection as well as enhanced edge coverage and color retention. D Interchangeable modular panel construction. Allows complete serviceability or replacement without compromising enclosure design. D Internal exhaust silencer offering maximum component life and operator safety. D Attenuated design. Acoustic insulation UL 94 HF1 listed for flame resistance. D Service access. Multi-personnel doors for easy access to generator set control and servicing of the fuel fill, fuel gauge, oil fill, and battery. D Cooling/combustion air intake. Attenuated models offering fixed air inlet louvers. The 75 db(a) models include acoustic insulation lining with urethane film. D Cooling air discharge. Attenuated models offering a 90 vertical air outlet. Redirects cooling air up and above enclosures to reduce noise ambient; 75 db(a) models include acoustic insulation with urethane film. NOTE: Installing an additional length of exhaust tail pipe may increase backpressure levels. Please refer to the generator set spec sheet for the maximum backpressure value. G6-118 11/13d Page 3

Weather and Sound Options Distribution panel heater External emergency stop switch DC lights Incandescent lights Ventilation fan ADV-7630- Relay for motorized dampers Battery charger TImer for DC lights 3-way switch with GFCI Motorized discharge damper wiring Buttress kit (900--3600 gallon tanks only) Design Options - Weather - Sound - Aluminum Construction - Steel Construction - IBC Seismic Certified Basic Electrical Package (BEP) Distribution Panel/Load Center. Prewired AC power distribution of all factory-installed features including block heater, two GFCI-protected internal 120-volt service receptacles, internal lighting, and commercial grade wall switch. The load center is powered by building source power and protected by a main circuit breaker and circuit positions for future expansion. AC power distribution installed in accordance with NEC and all wiring within EMT thin wall conduit. Incandescent lights located within UL-listed fixtures designed for wet locations and two 3-way switches. - BEP available with single-phase, 100 amp. load center 120/240 VAC. - BEP available with three-phase, 125 amp. load center 120/208/ 240 VAC. Heater Heater, 5 kw Ceiling Mounted. Electrical utility heater prewired to load center inside the enclosure. Rated at 17100 Btu includes adjustable louvers offering down flow and horizontal air tuning, built-in thermostat with automatic fan delay controls. - Heater available in single phase at 240 VAC. - Heater available in three phase at 208 or 240 VAC. DC Light Package - DC Light Package (DLP). Prewired DC light package offering an economical alternative light source within the enclosure, as a complement to the BEP or a source of light when AC power is not available. Battery drain limited with fuse protection and controlled through a 0--60 minute, spring-wound, no-hold timer. - External Emergency Stop Switch. Externally mounted, recessed emergency stop switch. Motorized Variable Damper and Ventilation Ventilation Fan, 22.6 m 3 /min. (800 cfm) Wall Mount. Direct drive 3-blade 305 mm (12 in.) aluminum propeller fan with automatic shutters, driven by a totally enclosed air-over motor housed within a corrosion-resistant housing. Remote thermostatically controlled over a temperature range of 27 C to 54 C (80 F to 130 F). All components are prewired and installed. - Aluminum construction - Galvanized steel construction Motorized Air Inlets - Aluminum construction - Galvanized steel construction Motorized Air Outlets - Aluminum construction - Galvanized steel construction - Gravity Air Outlet Louver. Louvers closed when unit is not running. After the unit starts, the forced cooling air opens the outlet louvers. Miscellaneous Package Options - Battery Charger, Mounted. Mounting, prewiring of DC output and AC input when optional BEP is selected. Battery charger located inside the enclosure and accessible through an access door. Block Heater Wiring. Factory-supplied block heater prewired to a junction box providing a convenient location for the customer wiring of the block heater. - Heater available in single phase at 240 VAC. - Heater available in three phase at 208 or 240 VAC. - Panic Bar for each latching door. Provides additional safety for individuals working on the generator set while in the enclosure. Selection - Lifting base for enclosure (no fuel tank selected) - Fuel tank (see the following pages for features and options) G6-118 11/13d Page 4

Subbase Emergency outer tank relief vent Emergency inner tank relief vent Fuel leak detection switch Fuel level sender Removable engine supply diptube Removable fuel return diptube Additional fitting for optional accessory Additional fitting for optional accessory Normal vent Fuel fill with lockable cap and 203 mm (8 in.) riser Fuel level mechanical gauge Electrical stub-up area open to bottom Additional fitting for optional accessory Removable engine supply diptube Removable fuel return diptube GM82006-1A Standard Subbase Features D Extended operation. Usable tank capacity offers full load standby operation of up to 72 hours. D PowerArmorPlust textured epoxy-based rubberized coating that creates an ultra-thick barrier between the tank and harsh environmental conditions like humidity, saltwater, and extreme temperatures, and provides advanced corrosion and abrasion protection. D UL listed. Secondary containment generator set base tank meeting UL 142 tank requirements. D NFPA compliant. Designed to comply with the installation standards of NFPA 30 and NFPA 37. D Integral external lift lugs. Enables crane with spreader-bar lifting of the complete package (empty tank, mounted generator set, and enclosure) to ensure safety. D Emergency pressure relief vents. Meets UL requirements; ensures adequate venting of inner and outer tank under extreme pressure and/or emergency conditions. D Normal vent with cap. Vent is raised above lockable fuel fill. D Fuel level sender with fuel level and low and high fuel warning annunciated through the generator set controller. D Leak detection switch. Annunciates a contained primary tank fuel leak condition at generator set control. D Electrical stub-up area. D State tank designed to comply with the Florida Dept. of Environmental Protection (FDEP) File No. EQ-634 installation standards. G6-118 11/13d Page 5

State Code Subbase Options Bottom Clearance - I-beams, provides 106 mm (4.2 in.) of ground clearance Fuel in Basin Options - Fuel in basin switch, Florida Dept. of Environmental Protection (FDEP) File No. EQ-682 approved Fuel Fill Options - Fill pipe extension to within 152 mm (6 in.) of bottom of fuel tank - 18.9 L (5 gallon) spill containment with 95% shutoff - 18.9 L (5 gallon) spill containment - 18.9 L (5 gallon) spill containment fill to within 152 mm (6 in.) of bottom of fuel tank - 28.4 L (7.5 gallon) spill containment, Florida Dept. of Environmental Protection (FDEP) File No. EQ-226 approved - 28.4 L (7.5 gallon) spill containment with 95% shutoff, Florida Dept. of Environmental Protection (FDEP) File No. EQ-226 approved Fuel Supply Options - Fire safety valve (installed on fuel supply line) - Ball valve (installed on fuel supply line) Engine Fluid Containment - Removable engine fluid containment High Fuel Level Switch - High fuel level switch - High fuel level switch, Florida Dept. of Environmental Protection (FDEP) File No. EQ-682 approved - Three alarm panel - Three alarm panel, Florida Dept. of Environmental Protection (FDEP) approved Inner Tank Vent Options - 3.7 m (12 ft.) above grade (without spill containment) normal vent - 3.7 m (12 ft.) above grade (with spill containment) normal vent - 1.4 m (5 ft.) emergency vent Tank Marking Options - Decal, Combustible Liquids -- Keep Fire Away (qty. 2) - Decal, NFPA 704 identification (qty. 2) - Decal, tank number and safe fuel fill height (qty. 2) Freestanding Stairs - Stairs only - Stairs with platform - Stairs with catwalk G6-118 11/13d Page 6

and Subbase Specifications Capacity, L (gal.) Est. Fuel Supply Hours at 60 Hz w/full Load Weather and Subbase Max. Dimensions, mm (in.) Max. Weight, kg (lb.) * Length Width Height With Steel With Aluminum Height, mm (in.) 700/800REOZDE Lifting Base 0 7226 (284) 3250 (128) 9680 (21340) 9498 (20940) 254 (10) 3301 (130) 12330 (27183) 12148 (26783) 305 (12) 6679 (1791) 24 3504 (138) 12756 (28121) 12574 (27721) 508 (20) 7994 (315) 2645 (104) 8215 (2170) 36 3606 (142) 12957 (28565) 12775 (28165) 610 (24) 10824 (2859) 48 13318 (29360) 13136 (28960) 3910 (154) 16193 (4278) 72 9567 (377) 14316 (31560) 14134 (31160) 914 (36) 900/1000REOZDE Lifting Base 0 7226 (284) 3250 (128) 11204 (24700) 11022 (24300) 254 (10) 3301 (130) 13854 (30543) 13672 (30143) 305 (12) 6679 (1791) 24 3504 (138) 14280 (31481) 14098 (31081) 508 (20) 7994 (315) 2645 (104) 14842 (32720) 14660 (32320) 13970 (3690) 48 3910 (154) 15174 (33453) 14992 (33053) 914 (36) 20914 (5525) 72 11430 (450) 16664 (36738) 16482 (36338) Sound Pressure with Full Load at 7 m (23 ft.), db(a) 90 89 Capacity, L (gal.) Est. Fuel Supply Hours at 60 Hz w/full Load Sound and Subbase Max. Dimensions, mm (in.) Length Width Height Max. Weight, kg (lb.) With Steel With Aluminum Height, mm (in.) 700/800REOZDE Lifting Base 0 8826 (347) 3253 (128) 9915 (21860) 9688 (21360) 254 (10) 3304 (130) 12493 (27543) 12266 (27043) 305 (12) 6679 (1791) 24 3507 (138) 12919 (28481) 12692 (27981) 508 (20) 2645 (104) 8215 (2170) 36 9594 (378) 3609 (142) 13120 (28925) 12893 (28425) 610 (24) 10824 (2859) 48 13481 (29720) 13254 (29220) 3913 (154) 16193 (4278) 72 14479 (31920) 14252 (31420) 914 (36) 900/1000REOZDE Lifting Base 0 8826 (347) 3253 (128) 11457 (25260) 11231 (24760) 254 (10) 3304 (130) 14035 (30943) 13809 (30443) 305 (12) 6679 (1791) 24 3507 (138) 14461 (31881) 14235 (31381) 508 (20) 9594 (378) 2645 (104) 15023 (33120) 14797 (32620) 13970 (3690) 48 3913 (154) 15355 (33853) 15129 (33353) 914 (36) 20914 (5525) 72 11430 (450) 16845 (37138) 16619 (36638) Sound Pressure with Full Load at 7 m (23 ft.), db(a) 75 76 (900 kw) 77 (1000 kw) Note: Data in table is for reference only, refer to the respective ADV drawings for details. Note: Refer to TIB-114 for generator set sound data. * Max. weight includes the generator set (wet) with largest alternator option, enclosure, silencer, and tank (no fuel). G6-118 11/13d Page 7

KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-457-4441, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KOHLERPower.com Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65) 6264-6422, Fax (65) 6264-6455 and Subbase Specifications Capacity, L (gal.) Est. Fuel Supply Hours at 60 Hz w/full Load Weather and Subbase Max. Dimensions, mm (in.) Max. Weight, kg (lb.) * Length Width Height With Steel With Aluminum Height, mm (in.) 750/800REOZMD Lifting Base 0 7226 (284) 3250 (128) 10143 (22360) 9961 (21960) 254 (10) 3301 (130) 12793 (28203) 12611 (27803) 305 (12) 6679 (1791) 24 3504 (138) 13219 (29141) 13037 (28741) 508 (20) 7994 (315) 2645 (104) 13781 (30380) 13599 (29980) 13970 (3690) 48 3910 (154) 14113 (31113) 13931 (30713) 914 (36) 20914 (5525) 72 11430 (450) 15603 (34398) 15421 (33998) 900/1000REOZMD Lifting Base 0 7226 (284) 3250 (128) 13363 (29460) 13182 (29060) 254 (10) 3301 (130) 16013 (35303) 15832 (34903) 305 (12) 8215 (2170) 24 3606 (142) 16640 (36685) 16459 (36285) 610 (24) 7994 (315) 2645 (104) 17001 (37480) 16820 (37080) 13970 (3690) 48 3910 (154) 17333 (38213) 17152 (37813) 914 (36) 20914 (5525) 72 11430 (450) 18823 (41498) 18642 (41098) Sound Pressure with Full Load at 7 m (23 ft.), db(a) Capacity, L (gal.) Est. Fuel Supply Hours at 60 Hz w/full Load Sound and Subbase Max. Dimensions, mm (in.) Length Width Height Max. Weight, kg (lb.) With Steel With Aluminum Height, mm (in.) 750/800REOZMD Lifting Base 0 8826 (347) 3253 (128) 10369 (22860) 10142 (22360) 254 (10) 3304 (130) 12947 (28543) 12720 (28043) 305 (12) 6679 (1791) 24 3507 (138) 13373 (29481) 13146 (28981) 508 (20) 9594 (378) 2645 (104) 13935 (30720) 13708 (30220) 13970 (3690) 48 3913 (154) 14267 (31453) 14040 (30953) 914 (36) 20914 (5525) 72 11430 (450) 15757 (34738) 15530 (34238) 900/1000REOZMD Lifting Base 0 8826 (347) 3253 (128) 13589 (29960) 13362 (29460) 254 (10) 3304 (130) 16167 (35643) 15940 (35143) 305 (12) 8215 (2170) 24 3609 (142) 16794 (37025) 16567 (36525) 610 (24) 9594 (378) 2645 (104) 17155 (37820) 16928 (37320) 13970 (3690) 48 3913 (154) 17487 (38553) 17260 (38053) 914 (36) 20914 (5525) 72 11430 (450) 18977 (41838) 18750 (41338) Sound Pressure with Full Load at 7 m (23 ft.), db(a) 75 75 Note: Data in table is for reference only, refer to the respective ADV drawings for details. Note: Refer to TIB-114 for generator set sound data. * Max. weight includes the generator set (wet) with largest alternator option, enclosure, silencer, and tank (no fuel). DISTRIBUTED BY: Availability is subject to change without notice. Kohler Co. reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohlerr generator set distributor for availability. 2011, 2012, 2013 by Kohler Co. All rights reserved. G6-118 11/13d Page 8