OpenVMS Support for c-class Blades



Similar documents
QuickSpecs. What's New. At A Glance. Models. HP StorageWorks SB40c storage blade. Overview

How To Write An Article On An Hp Appsystem For Spera Hana

HP Direct-Connect External SAS Storage for HP BladeSystem Solutions Deployment Guide

HP ProLiant BL460c Gen9 Server Blade User Guide

QuickSpecs. HP Integrity cx2620 Server. Overview

HP BladeSystem - die neue c-class Generation

CUTTING-EDGE SOLUTIONS FOR TODAY AND TOMORROW. Dell PowerEdge M-Series Blade Servers

HP recommended configuration for Microsoft Exchange Server 2010: HP LeftHand P4000 SAN

DD670, DD860, and DD890 Hardware Overview

HP BladeSystem c7000 Enclosure

HUAWEI Tecal E6000 Blade Server

HP ProLiant BL660c Gen9 Server Blade User Guide

HP BladeSystem Onboard Administrator User Guide

HP ProLiant Server Booklet. Virtualization Reliability Efficiency Agility

Pioneer DreamMicro. Blade Server S75 Series

QuickSpecs. What's New Support for HP MSA 2040 Storage. Models. HP Smart Array P712m Controller. Overview

Windows Server 2008 R2 for Itanium-Based Systems offers the following high-end features and capabilities:

HP StoreEasy 1000 Storage Administrator Guide

VTrak SATA RAID Storage System

Cisco NAC Appliance Hardware Platforms

Cisco Unified Computing System Hardware

HP Virtual Connect Ethernet Cookbook: Single and Multi Enclosure Domain (Stacked) Scenarios

HP StoreVirtual 4630 Storage Maintenance Guide

HP Virtual Connect. Get Connected! Name: Matthias Aschenbrenner Title: Technical Consultant

Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server

HP ProLiant BL660c Gen9 and Microsoft SQL Server 2014 technical brief

HP Virtual Connect. Tarass Vercešuks / 3 rd of October, 2013

QUESTIONS & ANSWERS. ItB tender 72-09: IT Equipment. Elections Project

HP ProLiant BL685c G6 Server Blade User Guide

The Future of Computing Cisco Unified Computing System. Markus Kunstmann Channels Systems Engineer

How To Buy An Fujitsu Primergy Bx400 S1 Blade Server

HP ProLiant BL660c Gen8 Server Blade User Guide

BLADESYSTEM FIRMWARE UPDATES BEST PRACTICES

HP StoreEasy 1000 Storage Administrator Guide

Highly Scalable Server for Many Possible Uses. MAXDATA PLATINUM Server 3200 I

Fujitsu PRIMERGY Servers Portfolio

Data Sheet Fujitsu PRIMERGY BX900 S1 Blade Server

Lessons. What's a blade infrastructure? HP BladeSystem

SPEED your path to virtualization.

DD160 and DD620 Hardware Overview

PCI Express Impact on Storage Architectures and Future Data Centers. Ron Emerick, Oracle Corporation

Power Redundancy. I/O Connectivity Blade Compatibility KVM Support

Chapter 5 Cubix XP4 Blade Server

HP ProLiant BL460c Server Blade User Guide

Evaluation Report: HP Blade Server and HP MSA 16GFC Storage Evaluation

HP ProLiant WS460c Gen8 Workstation Blade User Guide

Introducing logical servers: Making data center infrastructures more adaptive

Cisco UCS Architecture Comparison

Servers, Clients. Displaying max. 60 cameras at the same time Recording max. 80 cameras Server-side VCA Desktop or rackmount form factor

The Advantages of Multi-Port Network Adapters in an SWsoft Virtual Environment

HP BladeSystem c7000 Enclosure Setup and Installation Guide

Redundancy in enterprise storage networks using dual-domain SAS configurations

FUJITSU Enterprise Product & Solution Facts

QuickSpecs. What's New Boot from Tape. Models HP Smart Array P411 Controller

System x3650 Type 7979

Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server

Certification: HP ATA Servers & Storage

How to configure Failover Clustering for Hyper-V hosts on HP ProLiant c-class server blades with All-in-One SB600c storage blade

5520UR 00UR 00UR 625UR 625URSAS 00UR URBRP 600URLX 625URLX

HP ConvergedSystem 900 for SAP HANA Scale-up solution architecture

Copyright 2013, Oracle and/or its affiliates. All rights reserved.

QuickSpecs. HP Smart Array 5312 Controller. Overview

Sun Microsystems Special Promotions for Education and Research January 9, 2007

QuickSpecs. Models. HP StorageWorks Modular Smart Array 50 Enclosure. HP StorageWorks Modular Smart Array 50 Enclosure. Overview

HP BladeSystem. Family guide

Microsoft Exchange Server 2007 and Hyper-V high availability configuration on HP ProLiant BL680c G5 server blades

NEC EXPRESS5800/R320c-E4 Configuration Guide

SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION

QuickSpecs. HP Integrity Virtual Machines (Integrity VM) Overview. Currently shipping versions:

HP Systems Insight Manager 7.0 and HP Agentless Management overview

Annex 1: Hardware and Software Details

How To Configure Your Computer With A Microsoft X86 V3.2 (X86) And X86 (Xo) (Xos) (Powerbook) (For Microsoft) (Microsoft) And Zilog (X

Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server

HP PCIe IO Accelerator For Proliant Rackmount Servers And BladeSystems

HP Integrity BL860c i4, BL870c i4 & BL890c i4 Server Blade User Service Guide

Fujitsu PRIMERGY BX600 S3 Blade Server

Cisco MCS 7845-I2 Unified Communications Manager Appliance

U.S. Product Specifications Reference PSREF. Version 483, December ThinkServer Servers. Visit for the latest version

Fujitsu PRIMERGY Servers Portfolio

integrated lights-out in the ProLiant BL p-class system

EDUCATION. PCI Express, InfiniBand and Storage Ron Emerick, Sun Microsystems Paul Millard, Xyratex Corporation

Arrow ECS sp. z o.o. Oracle Partner Academy training environment with Oracle Virtualization. Oracle Partner HUB

HP BladeSystem p-class System Overview and Planning

PCI Express Impact on Storage Architectures and Future Data Centers. Ron Emerick, Oracle Corporation

29/07/2010. Copyright 2010 Hewlett-Packard Development Company, L.P.

HP reference configuration for entry-level SAS Grid Manager solutions

Support a New Class of Applications with Cisco UCS M-Series Modular Servers

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure

UCS M-Series Modular Servers

HP Cloudline Overview

HP ProLiant DL380 G5 High Availability Storage Server

Data Sheet Fujitsu PRIMERGY BX600 S3 Blade Server

Private cloud computing advances

Optimized dual-use server and high-end workstation performance

IBM BladeCenter H with Cisco VFrame Software A Comparison with HP Virtual Connect

QuickSpecs. What's New. Models. HP ProLiant Essentials Performance Management Pack version 4.4. Overview

HP VMware ESXi 5.0 and Updates Getting Started Guide

Transcription:

OpenVMS Support for c-class Blades John Shortt HP OpenVMS Engineering 27-Sep-2007 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice

Topics Features of HP c-class Blade systems What makes up a c-class Blade system OpenVMS Plans Using c-class Blade systems Configuring Hardware Firmware Updates Provisioning (Installation) Management October 11, 2007 2

Features of HP c- Class Blade Systems? October 11, 2007 3

Why c-class Blades High cost of IT infrastructure Cost of acquisition vs. cost of ownership Inflexible IT infrastructure Speed in introducing IT change Space savings more compute power in a smaller footprint compared to equivalent number of processors in racked servers Cable management and fewer cables to connect servers to LAN/SAN October 11, 2007 4

Why c-class Blades (cont) Power/cooling efficiencies Reduce Cost! Ease of management more consistency across OS/architecture Flexibility easy to change Fewer spare parts All of the above translate into lower cost of acquisition and cost of ownership compared to discrete servers October 11, 2007 5

A cross-hp solution platform HP Onboard Administrator: HP printer and copier LCD meet datacenter control HP StorageWorks storage blades StorageWorks inside the enclosure. A new storage solution paradigms for modular storage HP Integrity and ProLiant server blades Scale-Out meets Scale-Up creating new blade paradigms for modular computing solutions Workstation and client blades Extending the blading impact to more of IT Infrastructure automation Policy-based management solutions automate common and labor intensive tasks HP Active Cool fans and HP Dynamic Power Saver: HP Cool Team meets high density power/cooling problems head-on October 11, 2007 6

BL860c Server Blade October 11, 2007 7

BL860c Server Blade 2 Processor Sockets Single or Dual-core Itanium Processor 1.6GHz/6MB cache 1.4GHz/12MB cache 1.6GHz/18MB cache 12 DIMM slots DDR2 in 512MB to 4GB modules Configured in pairs or quads, 1GB to 48GB Fast Core or Integrated IO LSI 1068 Serial Attach SCSI (SAS) controller One channel for each on-board SAS drive Drives are Hot Plug 2 Broadcom BC5704S Gigabit Ethernet controllers 2-port controller Both are routed to the Interconnect Module in Row 0 3 PCI Express (PCIe) Mezzanine card slots Slot 1 is a Type I slot (x4) Slots 2 and 3 are Type II slots (x8) October 11, 2007 8

BL860c Management Logic Management Processor (MP) USB 2.0 controller ATI RN50 Graphics chip 10/100MB internal LAN connection Serial/USB/Video (SUV) connector ilo2 interface vmedia Virtual keyboard/video/mouse (vkvm) support Windows today Other OS support in future FW releases October 11, 2007 9

BL860c Mezzanine Cards Type I cards 15W max power x4 or x8 data lanes Can go in Type I or Type II slots Type II cards 25W max power x8 Type II slots only 4GB Fibre Channel Compatible with Integrity server FC PCIe pass-thru Supports Storage Blade SB40c Expect to see others NIC, Raid, FC October 11, 2007 10

Integrity BL860c Internal View 2 hot-plug SAS drive bays Front SAS backplane 2 cells, 12 DDR2 DIMM slots zx2 ASIC Mezzanine sockets: #2 (x8) #1 (x4) #3 (x8) Front panel TPM CPU 0 CPU 1 Processor/heatsink assembly CPU power pods October 11, 2007 11

The Enclosure October 11, 2007 12

c7000 Enclosure 10U form factor Fits in a standard 19 rack, 32 deep Capacity 8 full-height or 16 half-height Blade slots 8 Switch Module (SWM) slots 2 On-board Administrator (OA) slots 6 Hot pluggable power supplies 10 Hyperjet Coolers October 11, 2007 13

c7000 Enclosure Half-Height Blade Server Up to 16 per enclosure Full-Height Blade Server Up to 8 per enclosure 10U Onboard Administrator HP Insight Display, set-up simplification Integrated power Simplified configuration and greater efficiency Same flexibility, capacity and redundancy October 11, 2007 14

c7000 Enclosure fully redundant Active Cool fans Interconnect bays Onboard Administrator Power management October 11, 2007 15

c7000 HP c-class C-Class Signal midplane C-Class Power backplane Separate signal and power midplanes Passive signal midplane with 1 active component that is not in the signal path Solid copper plates make up power backplane 24-layer PCB which provides over 1600 high quality copper traces October 11, 2007 16

Interconnect/Switch Modules Rear of the enclosure contains 8 slots for SWMs Configured as 4 rows of 2 slots or bays (R0-R3) Row 0 dedicated to integrated Network connections 2 NICs per Blade, 2 ports each, 32 max ports Each SWM handles 16 ports Three types today Pass-thru Vendor switch Virtual Connect October 11, 2007 17

c7000 Interconnect Routing Server IO Interconnect Bay Comments NIC1 and NIC2 1 and 2 Integrated Ports Mezz Slot 1 3 and 4 Type I slot Mezz Slot 2 5 and 6 (Primary) 7 and 8 (Secondary) Type II slot Mezz Slot 3 7 and 8 (Primary) 5 and 6 (Secondary) Type II slot October 11, 2007 18

Virtual Connect Network and Fibre Channel SWMs plus Virtual Connect Manager (VCM) VCM runs on Network SWM in bay 1 or bay 2 (at least one Network VC switch is required for VC support) With 2 network switches you get redundant network paths and VCM failover highly recommended Create VCM domain that describes your VC environment Blade profiles Networks SANs Virtual Connect provides a wire once infrastructure VCM adds no overhead to Network and FC transfers! October 11, 2007 20

HP Virtual Connect Ethernet Module MidPlane 16x 1Gb Ethernet Connects to one NIC in each HH blade server bay 1x 10Gb Cross-link between adjacent VC-Enet modules Mgmt Interfaces to Onboard Administrator (Enet & I2C) 2x 10Gb Ethernet (CX4) Usable as data center links or as stacking links. Recessed module reset button 8x 1Gb Ethernet (RJ45) Usable as data center links or as stacking links. Port Number & Status Indicators Indicates whether a data center link (green), stacking link (amber), or highlighted port (blue). Next button (unused in initial release firmware) October 11, 2007 21

On-board Administrator (OA) Manages all enclosure related items thermal, power, Switch Modules, Blades 2 Slots in the rear of the enclosure Interfaces HTML-based GUI via HTTPS CLI interface via RS-232 (Local connector), SSH, or Telnet Management Protocols SNMP today October 11, 2007 23

OA IPMI via ilo on local 10/100 link ekey to link Mezzanine card with SWM Power on control for Blade Dynamic Power and Cooling control Enclosure Profile setup once Real time monitoring data Firmware updates SWM console interface October 11, 2007 24

c3000 Enclosure 6U Form Factor New Midplane and Power Supply Capacity 4 full height/8 half-height slots 6 Power Supplies 6 Fans 4 Interconnect bays 1 OA DVD October 11, 2007 25

C3000 October 11, 2007 26

c3000 Midplane Routing Server IO Interconnect Bay Comments NIC1 and NIC2 1 Integrated Ports Mezz Slot 1 2 Type I slot Mezz Slot 2 3 and 4 Type II slot Mezz Slot 3 3 and 4 Type II slot October 11, 2007 27

Other Blades October 11, 2007 28

SB40c Storage Blade Direct Attach storage Smart Array raid controller Support for up to 6 SAS drives Connects to adjacent Processor Blade with PCIe pass-thru mezzanine card Half-height Blades put module in mezz slot 2 Full height Blades put module in mezz slot 3 Can go in either slot of a partition (left or right of the pair) October 11, 2007 29

October 11, 2007 30

Ultrium 448c Tape Blade LTO Ultrium 2 400GB capacity Requires PCIe Pass-thru module in mezzanine slot 3 of adjacent Server Blade Supported on Proliant today, Integrity around the end of the year October 11, 2007 31

PCI Sidecar IO Blade for PCIx or PCIe stand up modules Comes with a backplane for each Install the desired flavor Each has 2 available slots Support for 3 rd party modules only no HP modules are supported Released for Proliant Blades today, Integrity end of the year October 11, 2007 32

OpenVMS Plan October 11, 2007 33

OpenVMS Plan Base c-class support June 1, 2007 V8.3 with update/patch kits SB40c (added support in July) Virtual Connect (added support in Sept) Additional features in release V8.3-1H1Nov 2007 Provisioning Web Based Enterprise Management (WBEM Providers) vmedia Montvale c3000 Enclosure October 11, 2007 34

Using c-class Blade Systems October 11, 2007 35

Configuring the c-class Blade System Questions Mixed Integrity and Proliant Server Blades? Storage Blades? Redundant Network connections? Redundant FC connections? Redundant airflow? Redundant power? Virtual Connect? October 11, 2007 36

Adding c-class Blades General rule is left to right installation Half-height Blades can be stacked, as well as halfheight Blades on top of Storage Blades There is no requirement that empty slots are to be avoided Blades can be added or removed without powering off anything Remember, all server slots are routed to each interconnect slot Mezzanine cards must be configured based on Interconnect module requirements October 11, 2007 37

Adding Interconnect Modules Network modules must be placed in Bay 1 and/or Bay 2 Both for redundancy For VC, both for VCM failover Bays 3-8 depend on mezzanine cards Bays 3 and 4 relate to mezz slot 1 Bays 5 and 6 (7 and 8) to mezz slot 2 Bays 7 and 8 (5 and 6) to mezz slot 3 October 11, 2007 38

c7000 Interconnect Model (Half-Height Server Blade) PCIe x4 NIC 2 1 N Inter. Bay 1 N Inter. Bay 2 PCIe x4 PCIe x8 Mezz-1 Mezz-2 4 3 2 1 4 3 2 1 X X Half-Height Server Blade N (N= 1. 16) Up to 160 Gb/s per direction. 16 Lanes per connector Up to up to 10Gb/s per lane N Inter. Bay 3 N Inter. Bay 5 N N Inter. Bay 4 N Inter. Bay 6 N Inter. Bay 7 Inter. Bay 8 Inter. Bay 1 Inter. Bay 3 Inter. Bay 5 Inter. Bay 7 Inter. Bay 2 Inter. Bay 4 Inter. Bay 6 Inter. Bay 8 October 11, 2007 39

c7000 Interconnect Model (Full-Height Server Blade) PCIe x4 N PCIe x4 PCIe x8 NIC 2 1 4 3 2 1 4 3 2 1 Mezz-1 Mezz-2 Up to 320 Gb/s per direction. Inter. Bay 1 Inter. Bay 3 Inter. Bay 5 Inter. Bay 2 Inter. Bay 4 Inter. Bay 6 N + 8 PCIe x4 PCIe x8 NIC 2 1 Mezz-3 4 3 2 1 Full-Height Server Blade N (N= 1. 8) 32 Lanes per FH Inter. Bay 7 Inter. Bay 8 Inter. Bay 1 Inter. Bay 3 Inter. Bay 5 Inter. Bay 7 Inter. Bay 2 Inter. Bay 4 Inter. Bay 6 Inter. Bay 8 October 11, 2007 40

c-class Power and Airflow Power Supplies Minimum Slot 1 and Slot 4 4 to 6 supplies provide redundancy select AC or DC Fans Minimum of 4 Fans 2 left and 2 right 8-10 for redundancy (middle empty with 8) Install everything and turn on standby power, the OA will go through its startup script OA will ask for power redundancy scheme If the fan quantity and/or power supply number is inadequate the OA will let you know October 11, 2007 41

Enclosure Module Access On-board Administrator Get IP address from OA display Browse to the ilo TELNET to the CLI Serial Connection Use tag for OA name and password Configure IP, name, password, etc. Interconnect Modules Local CLI Browse via OA Look for tag October 11, 2007 42

Management Processor Access TELNET to the Management Processor on each individual Blade Traditional method of console access Browse to the MP (ilo2) SUV cable for serial/usb/vga connection to each Blade Use Tag for login information Future support for Virtual KVM (vkvm) October 11, 2007 43

Management Console Access SUV BL860c SWM1 1Gb Network 1Gb Network BL860c SWM2 1Gb Network 1Gb Network BL860c SWM3 4Gb FC 4Gb FC Storage Blade Midplane SM4 4Gb FC 4Gb FC Empty Slot SWM5 SUV BL860c SWM6 Empty Slot SWM7 BL860c SM8 ` 10/100 Network On-board Administrator Serial October 11, 2007 44

Check Firmware Update OA first Interconnect Modules Server Blade Baseboard Management Controller (BMC) Management Processor (MP) System Firmware (SFW) Integrated IO (FRU EEPROMs for example) Mezzanine Cards Storage Blades October 11, 2007 45

HP BladeSystem usage scenarios End-to-end provisioning 01010011001010110 11101000100011101 01110010101101001 01011101001010101 Provision solutions across compute, network, and storage in minutes Dynamic scaling Automated server recovery production spare Deliver economical high availability via resource pooling and auto-recovery Rapid IT consolidation Scheduled re-provisioning Improve system utilization through scheduled reprovisioning Patch and vulnerability Dynamically scale infrastructure based on performance needs Consolidate legacy compute nodes on high performance platforms Quickly assess and respond to potential security vulnerabilities October 11, 2007 46