The Calibration Chain: Role of BIPM,



Similar documents
IAS CALIBRATION and TESTING LABORATORY ACCREDITATION PROGRAMS DEFINITIONS

ABSORBED DOSE DETERMINATION IN EXTERNAL BEAM RADIOTHERAPY

Worldwide Quality Assurance networks for radiotherapy dosimetry

RECOMMENDATION. on the Evaluation of Quality Management System of National Metrology Institutes

APMP/TCRI Key Comparison Report of Measurement of Air Kerma for Medium-energy X-Rays (APMP.RI(I)-K3)

Principles of dosimetry The ionization chamber

Case study Realistic and best uncertainties with humidity instruments

Radiation survey meters used for environmental monitoring

Chapter 9 CALIBRATION OF PHOTON AND ELECTRON BEAMS

Bonn Call-for-Action Joint Position Statement by the IAEA and WHO

Accreditation according to ISO/IEC in Europe. Historic EA Europeing Accreditation Assessment Experience from Technical assessment

EUROLAB 25 years. The role of metrology and testing to characterize materials and products. EUROLAB 25th Anniversary Seminar

CRITERIA FOR PERFORMING CALIBRATION AND INTERMEDIATE CHECKS ON EQUIPMENT USED IN ACCREDITED FACILITIES

International time scales Atomic standards

NRC Publications Archive Archives des publications du CNRC

OIML D 18 DOCUMENT. Edition 2008 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

Quality Assurance of Radiotherapy Equipment

1. Provide clinical training in radiation oncology physics within a structured clinical environment.

There must be an appropriate administrative structure for each residency program.

Certificate of Calibration No

Albany Medical Center Chief Medical Physicist Radiation Oncology Imaging and Related Services

The age of competence: an update on the international laboratory accreditation scene for veterinary testing laboratories

International Organization for Medical Physics Activities related to Radiological Protection of Patients

NIST HANDBOOK CHECKLIST CONSTRUCTION MATERIALS TESTING

AAPM s TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams

High-Energy Electron Beam Therapy Dosimetry with Ionisation Chambers

Ionizing Radiation, Czech Republic, CMI (Czech Metrology Institute)

International Organization for Standardization

ISO/IEC ACCREDITATION REQUIREMENTS FOR CALIBRATION LABORATORIES

Calibration Certificate

THERMAL INSULATION MATERIALS

American Association for Laboratory Accreditation

United States Office of Radiation and October 1998 Environmental Protection Indoor Air Agency. Radiation and Indoor Environments National Laboratory

INTRODUCTION. A. Purpose

AAPM protocol for kv x-ray beam dosimetry in radiotherapy and radiobiology

ROLE OF THE APEC SPECIALIST REGIONAL BODIES

ELECTRONIC MEDICAL RECORDS (EMR) STREAMLINE CH I PROCESS. Ping Xia, Ph.D. Head of Medical Physics Department of Radiation Oncology Cleveland Clinic

STATE OF NEVADA Department of Administration Division of Human Resource Management CLASS SPECIFICATION

Procedure for Equipment Calibration and Maintenance

The BIPM, the Time Department and UTC

The role, responsibilities and status of the clinical medical physicist in AFOMP

RADIATION PROTECTION CO-OPERATION. No. 8. Nordic dosimetric capabilities Resources, needs and plans

Calibration Service Selection Guide

Chapter 3: Radiation Dosimeters

IAEA Human Health Programme

NEW YORK STATE DEPARTMENT OF HEALTH BUREAU OF ENVIRONMENTAL RADIATION PROTECTION EXTERNAL BEAM & BRACHYTHERAPY QUALITY ASSURANCE PROGRAM AUDIT FORM

Physical Quantities, Symbols and Units

Introduction to EMC Antenna Calibration Methods:

American Association for Laboratory Accreditation

Quality Management Systems for Seed Testing Laboratories: Presented to the 2010 CSAAC Meeting. Valerie Martz Senior Laboratory Accreditation Officer

AUDIT PROTOCOL FOR THE VICTORIAN WATER QUALITY MONITORING NETWORK

RADIATION ONCOLOGY PRACTICE STANDARDS A TRIPARTITE INITIATIVE

International Laboratory Accreditation Cooperation. Laboratory Accreditation or ISO 9001 Certification? global trust. Testing Calibration Inspection

Solar Radiation Measurement. Bruce W Forgan, WMO RAV Metrology Workshop, Melbourne, Novemberr 2011

Measuring equipment in a laboratory.

Form and content of COOMET сertificate for reference materials for composition and properties of substances and materials

RADIATION THERAPY. Dosimetry Pioneers since 1922 NEW

Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators

SOP #: Revision #: Current Version Implementation Date: Page #: Page 1 of 10 Last Reviewed/Update Date: Expiration

Accreditation Is Coming

TITLE: Quality System Manual DOCUMENT NUMBER: QMS

Measuring Patient Exposure in Interventional Radiology

Portuguese Health Physics Society: Calibrating Pen Dosimeters with and without a Phantom

High Level Importance: ISO Microbiology compliance

ACCELERATORS AND MEDICAL PHYSICS 2

Enhancing of Regulatory Control in Georgia Main Trends and Current Developments

THE ROLE OF A PHYSICIST IN RADIATION ONCOLOGY

9. Quality Assurance 9.1 INTRODUCTION 9.2 FIELD SAMPLING QUALITY ASSURANCE 9.3 ANALYTICAL QUALITY ASSURANCE Internal Quality Control

GENERAL REQUIREMENTS FOR THE PROGRAMME OF REFERENCE MATERIAL CERTIFICATION IN SERIAL PRODUCTION

PERSONNEL MONITORING AND DOSIMETRY POLICIES

Directory of State and Local Government Laboratory Accreditation/Designation Programs

First Three Years After Project Proton Therapy Facility:

MEDICAL DOSIMETRY. COLLEGE OF APPLIED SCIENCES AND ARTS Graduate Faculty: therapy.

Check-list for auditors. Audit visit at candidate registered laboratories

Preface to Practice Standards

Canadian Partnership for Quality Radiotherapy. Quality Assurance Guidelines for Canadian Radiation Treatment Programs

QUALITY MANAGEMENT IN VETERINARY TESTING LABORATORIES

CHAPTER 9. CALIBRATION OF PHOTON AND ELECTRON BEAMS

An Alternative Method for Maintaining ISO 9001/2/3 Certification / Registration

Security Compliance: Making the Proper Decisions

NEW JERSEY RADIOLOGIC TECHNOLOGY BOARD OF EXAMINERS (BOARD) ACCREDITATION STANDARDS FOR SCHOOLS OF RADIATION THERAPY TECHNOLOGY

Basic Steps to Establish ISO/IEC Compliant Testing Laboratories

Professional Doctorate Program in Medical Physics (DMP) University of Cincinnati. Program Assessment. August 2014

Establishing a Patient Safety Program in Radiation Oncology

Production of X-rays and Interactions of X-rays with Matter

The feasibility of a QA program for ISIORT Trials

centre for radiation protection

Regulatory Requirements for Medical Device Calibration Programs

Calibration of Electronic Test Equipment: An Introduction to ISO & Accreditation

NIST HANDBOOK 150 CHECKLIST

PHYSICAL QUANTITIES AND UNITS

The IAEA/WHO TLD postal programme for radiotherapy hospitals

Great Lakes National Program Office and Office of Water Quality Management Training Modules

American Association for Laboratory Accreditation

ISO Accreditation for a Standing Start Finish (SSF) Primary Flow Stand with Coriolis Flowmeters as Reference Standards.

The International System of Units (SI)

Memorandum of Understanding

Calibration Laboratories

STANDARD OPERATING GUIDELINES: EVIDENTIAL BREATH ALCOHOL INSTRUMENT CALIBRATION

Proficiency testing schemes on determination of radioactivity in food and environmental samples organized by the NAEA, Poland

Transcription:

The Calibration Chain: Role of BIPM, PSDLs and ADCLs J. Seuntjens and M. McEwen McGill University & National Research Council CANADA Clinical Dosimetry for Radiotherapy, 2009 AAPM Summer School

PSDL ADCL NVLAP A2LA SSDL accreditation NIST a talk about jargon IAEA WHO ISO 17025 BIPM MRA CCRI

Rhetoric Question What is a Round Robin? a) An orange bellied bird with constipation issues b) A dosimetryintercomparison program carried out between ADCLs, in which the comparison is not made to a primary standard, but just between secondary standards laboratories c) A friendly, open minded Summer School ) y, p arrangement committee member

Radiotherapy Treatment Consistency Standardization and qualitycontrol Radiation therapy Diagnosisi Planning Radiation Delivery Post treatment evaluation In radiation therapy a standard can be a procedure and/or an artifact Dosimetry

Radiation Dosimetry Traceability Calibration Chain Verification, QA and audits

CALIBRATION CHAIN PSDL (NIST or NRCC) T N D,w ADCL SSDL or ADCL beam AAPM CLA Clinical beam Q Q N D,w clinic D w clinic RPC

What is a PSDL? Primary Standards Dosimetry Laboratory The national laboratory designated by the government for the purpose of developing, maintaining and improving primary radiation standards NIST (Gaithersburg) or NRCC (Ottawa) In some countries there are no PSDLs 7

Primary Dosimetry Standard Instrument t that atao allows sthe edetermination of absorbed dose according to its definition Preferably with a direct path to SI quantities not involved with ionizing radiation SI base unit: meter, kilogram, second, ampere, kelvin, mole, and candela SI derived units: J, Gy, etc. the path to base SI units is not always as direct as we would like

Ionizing Radiation Related Quantities SI derived Method SI base Unit quantities Absorbed dose Gy (J/kg) calorimetry Temperature, to water mass, length, time Exposure C/kg Free air or cavity ionization chamber current, mass, time Air kerma Gy Free air or cavity ionization chamber current, mass, time(*) (*) () requires the use of the product W/e (L/ (/ cair c,air

Water calorimeter Measurement of energy, mass and temperature energy = mass * length 2 / time 2 temperature No ionizing radiation needed to determine thisquantity Green: SI base unit orange: SI derived unit

Free air ionization chamber or cavity ionization chamber Measurement of current, time Length, density Density = mass / length 3 No ionizing radiation needed to dt determine the volume Green: SI base unit orange: SI derived unit

Does require the use of ionizing radiation Free air ionization chamber or cavity ionization chamber Measurement of current, time Length, density Density = mass / length 3 No ionizing radiation needed to dt determine the volume Green: SI base unit orange: SI derived unit

Absolute dosimetry Measurement of absorbed dose using a primary standard Absorbed dose measurement in absolute terms in clinical context (in reference field and at reference depth): clinical reference dosimetry

The Bureau International des Poids et Mesures (BIPM) BIPM = International laboratory created by the BIPM International laboratory created by the metre convention; has an Ionizing Radiation Division Role: development, maintenance of standards and intercomparison programs between primary standards laboratories Intercomparison programs involve the use of secondary standards, maintained at PSDLs www.bipm.org

The BIPM (cont d) Through thebipm intercomparison program the NMi can declare its calibration and measurement capabilities (CMCs) Key comparisons and database (http://kcdb.bipm.org) bipm Mutual recognition agreement (MRA) Mutual recognition arrangement (MRA) CCRI Meetings (in Paris, dans la ville des villes, with excellent wine)

Secondary Standards Dosimetry Laboratories (SSDLs) IAEA SSDL network SSDL= Laboratory designated by a competent national authorities to provide the necessary link in traceability of radiation dosimetry to national/international standards for users within that country

SSDL characteristics Must take part in comparisons organized by the SSDL network (IAEA WHO administered) Two types of SSDLs 1. SSDLs that fulfill a a national metrological function (oftentherethere is no PSDL) 2. SSDLs that serve a group of local clinical centres without formal national mandate

SSDL network

What is an ADCL? Accredited Dosimetry Calibration Laboratory (the SSDL equivalent in NA but different ) Accredited by the AAPM Provides calibrations lb to users for instruments and radioactive sources for dosimetry in radiotherapy and diagnostic imaging g Currently three ADCLs: University of Wisconsin (Madison) K&SAssociates (Nashville) MD Anderson Cancer Centre (Houston) http://uwrcl.medphysics.wisc.edu/ http://www.kslab.com http://rpc.mdanderson.org/adcl/ 19

The AAPM CLA subcommittee: what does it do? Oversee all activities regarding the operations of the ADCLs. The Subcommittee s task is to accredit, supervise and maintain the highest level of confidence in the quality of the ADCL system, with sufficient capacity in the system to prevent undue delays in satisfying the membership ss calibration needs while providing a choice of ADCLs. Main forum for discussion of issues relating to calibration of ion chambers and brachytherapy sources 20

Some history In 1971 the AAPM formed a task group to develop guidelines for the establishment of a system of secondary standard calibration laboratories. The laboratories would be accredited by the AAPM to provide highprecision dosimetrycalibrations calibrations. They would be outside of the National Institute of Standards and Technology (National Bureau of Standards as it was then) but traceable to NIST. Purpose: To reduce the time required for precision calibrations To create a system of secondary standard laboratories, To establish a technical resource for the membership of the AAPM 21

Time progresses A sub committee of the Radiation Therapy Committee of AAPM has overseen the development of the program to this day. Names have changed but the focus is still the same At the summer meeting of the AAPM in 1995, the Subcommittee initiated a major revision of the accreditation protocol which has resulted in the present criteria that now conform to ISO standard 17025:2005. 22

What does the CLA do? Develops criteria Accredits laboratories lb Carries out assessment visits Monitors performance Makes recommendations 23

What does the CLA not do? Does not set prices Does not recommend any one ADCL over another Does not distinguish between commercial and academic organizations Does not try to spread the business around 24

Accreditation Procedure by which an authoritative body gives formal recognition that a body or person is competent to carry out specific tasks 25

ADCL Accreditation Formal recognition that a testing laboratory is competent to carry out specific tests or types of tests Key Words: competent specific tests (scope of testing) Accreditation means having a Quality System and demonstrating competency. Requires assessment (audit) visits to the laboratory to verify competency. 26

Activities of ADCLs in the context of maintenance of accreditation Perform proficiency tests = inter comparisons with the PSDL (NIST) on a rigid schedule Perform round robins = inter comparisons amongst ADCLs on a rigid schedule Undergo site visits ii from the CLA Undergo surveillance visits from the CLA Report activities to the CLA

Radiological Physics Center See next presentation

Summary Clinical dosimetry in NA is traceable to national standards through a chain connecting clinics to ADCLs and PSDLs. National standards are declared equivalent through an MRA and key comparisons In NA, ADCLs are monitored by the CLA subcommittee of the AAPM ADCLs are accredited by CLA subcommittee by testing them against the AAPM criteria Proficiency tests Audits, Site visits ADCLs in NA are first class

Thank You