Oscilloscope System Recovery Tools and Procedures



Similar documents
Getting Started User s Guide

Microsoft Windows 7 Ultimate 64 Bit SP1 Operating System Recovery Media for 300 GB Solid State Drives Instructions

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 16 Fixing Windows Problems

Acronis Backup & Recovery 11.5 Quick Start Guide

Vess A2000 Series. NVR Storage Appliance. Windows Recovery Instructions. Version PROMISE Technology, Inc. All Rights Reserved.

Time Stamp. Instruction Booklet

4 Backing Up and Restoring System Software

Q: How to use MSI BurnRecovey on Windows 10 preloaded system?

Dual-boot Windows 10 alongside Windows 8

Acronis Backup & Recovery 11

Motorola Phone Tools. Quick Start

Secure Perfect RAID Recovery Instructions

VERITAS Backup Exec 9.1 for Windows Servers Quick Installation Guide

3M Occupational Health and Environmental Safety 3M E-A-Rfit Validation System. Version 4.2 Software Installation Guide (Upgrade) 1 P age

Chapter 4. Backup / Restore

Windows 7. Tips and Tricks. Scott Sekinger

Boot Camp Installation & Setup Guide

Image Backup and Recovery Procedures

Yamaha 01V96 Version2 Upgrade Guide

Intel Data Migration Software

Centurion PLUS CPC4 Download Guide

Q1. What are the differences between Data Backup, System Restore, Disk Image, System Recovery Disc and System Repair Disk?

Lab: Data Backup and Recovery in Windows XP

Acer erecovery Management


Image Assistant. User Guide. Image Assistant. Laplink Software, Inc. User Guide. The ONLY Way to Restore an Old Image to a New PC!

Iridium Extreme TM Satellite Phone. Data Services Manual

VERITAS Backup Exec TM 10.0 for Windows Servers

Image Backup and Recovery Procedures

PC Angel. Recovery. Page 1

Guide to Installing BBL Crystal MIND on Windows 7

Boot Camp Installation & Setup Guide

Symantec Backup Exec TM 11d for Windows Servers. Quick Installation Guide

VirtualXP Users Guide

Intel Data Migration Software

SOS Suite Installation Guide

User Guide. Windows 8 Upgrade Assistant. Laplink Software, Inc. MN-PCM-UpgdAssist-EN-08 (REV. 10/2012)

2.6.1 Creating an Acronis account Subscription to Acronis Cloud Creating bootable rescue media... 12

Lab - Data Backup and Recovery in Windows XP

FAQ No Q: What should we know before we start Windows 10 upgrade?

C6 Easy Imaging Total Computer Backup. User Guide

Acronis Backup & Recovery 10 Server for Windows. Installation Guide

QBalance.com. We make QuickBooks work for you. Call Toll-Free: (800) Congratulations! You are using the best accounting software available!

Getting Started with WebEx Access Anywhere

Instrument Software Update Instructions. Keysight X-Series Signal Analyzers (PXA/MXA/EXA/CXA) Upgrading an older version to A.12.

Also you need the C-MOR ISO file. This file you will find following this link:

Computer Backup Issues For Windows 8

Transferring AIS to a different computer

Microsoft BackOffice Small Business Server 4.5 Installation Instructions for Compaq Prosignia and ProLiant Servers

Acronis Backup & Recovery 10 Server for Windows. Workstation. Quick Start Guide

Cleaning your Windows 7, Windows XP and Macintosh OSX Computers

Infiniium Upgrade and Recovery Guide

XTreme Files OS & Data Backup/Restore User Manual Please read the Instruction manual before using the XTreme Files (F Series) 1.

2.5" XTreme Files OS & Data Backup/Restore User Manual Please read the Instruction manual before using the XTreme Files (X Series) 1.

Accounts Production Installation Guide

C6 Easy Imaging Total Computer Backup. User Guide

Driver Updater Manual

Printer Driver Installation Guide

NetBak Replicator 4.0 User Manual Version 1.0

XConsole GUI setup communication manual September 2010.

Updates Click to check for a newer version of the CD Press next and confirm the disc burner selection before pressing finish.

SmartSync Monitor Help

1. System Requirements

Colorfly Tablet Upgrade Guide

A+ Guide to Software: Managing, Maintaining, and Troubleshooting, 5e. Chapter 3 Installing Windows

Installing Global Logger USB Drivers

Operating System Installation Guide

Introduction. This white paper provides technical information on how to approach these steps with Symantec Antivirus Corporate edition.

Acronis Backup & Recovery 10 Workstation. Installation Guide

Nexio Backup and Recovery

USB External Hard Disk Drive

Hi-Speed USB Flash Disk User s Manual Guide

Juniper NetScreen IPSec Dial Client. Installation Guide for Windows 2000 Windows XP Windows Vista

Elo 1725L 17 Touch Screen Monitor Installation Guide. Product Name: Elo 1725L 17- inch Monitor

Drive Vaccine PC Restore

CASPER SECURE DRIVE BACKUP

Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.

Using Acronis True Image

SOFTWARE INSTALLATION INSTRUCTIONS

CLEARONE DOCUMENT (REVISION 1.0) October, with Converge Pro Units

Contents. Hardware Configuration Uninstalling Shortcuts Black...29

Enterprise Site Manager (ESM) & Administrator Console Installation / Uninstall

ScanShell.Net Install Guide

Use Remote Desktop capabilities to Access your Work PC from home over VPN

USB DRIVER INSTALLATION GUIDE

HP RDX Continuous Data Protection Software Quickstart Guide

Preparations for and making a system back-up V2.8

Intel Rapid Storage Technology

STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER

Windows 8 Backup, Restore & Recovery By John Allen

Getting Started. rp5800, rp5700 and rp3000 Models

Motion Computing Tablet PC

Acronis Backup & Recovery 10 Server for Windows. Installation Guide

Classroom Management, part of Intel Education User Manual

Windows 7 Upgrade information

InventoryControl for use with QuoteWerks Quick Start Guide

Boot Camp Installation & Setup Guide

Symantec File Share Encryption Quick Start Guide Version 10.3

Using AORUS Notebook for the First Time

User's Guide. RecoveryExpert. Compute with confidence

Transcription:

Oscilloscope System Recovery Tools and Procedures Oscilloscope System Recovery Tools and Procedures Your oscilloscope is designed to operate reliably for many years. The application software operating the instrument runs on a Windows platform. The loading or incomplete removal of additional Windows applications can cause problems in the stability of the operating system. Severe cases may require a reloading of the base operating system and oscilloscope application. LeCroy provides you with an Acronis recovery application (Phoenix application on earlier models) and a backup image in an extra partition on the instrument s hard drive. PLEASE NOTE THE FOLLOWING: Recovery application software varies on different LeCroy instruments. Recent models use Acronis software while previous oscilloscopes used a Phoenix recovery utility. The recovery process produces a replica of the operating system and oscilloscope application software at the current revision levels when the oscilloscope was manufactured. Any further revisions of the application software, Windows operating system, and virus scan definition files are not automatically upgraded. Therefore, after completion of the disk image recovery, it is highly recommended to search vendor Web sites and upgrade the individual components to current revision levels. After the recovery procedure is completed, you must activate Windows, either by Internet connection to Microsoft s Web site or by telephone. Have your Windows Product Key number (located on the rear of the oscilloscope) handy during Widows reactivation. The current oscilloscope application software can be downloaded directly from the LeCroy website at www.lecroy.com. Since the calibration data for the oscilloscope is stored in the D: drive, current calibration constants are not overwritten during the recovery process. Which Recovery Application is on My Instrument? Find out which recovery application is on your instrument by minimizing the oscilloscope application using File Minimize from the menu bar. Now, from the instrument desktop go to Start All Programs and look for either an Acronis or Phoenix folder. PLEASE NOTE THE FOLLOWING: If the message includes the word Acronis during a boot attempt, use the Acronis resources and procedures. If you see no message to any effect of Acronis or otherwise, but then see the LeCroy logo on the screen, you should press F4 and follow the Phoenix resources and procedures. Since third-party recovery software is used, our instructions certainly may not be the most definitive or current. We advise you to take advantage of resources available on the Acronis or Phoenix websites - both companies maintain versions of their product manuals from the following locations: Acronis True Image Home http://www.acronis.com/homecomputing/download/docs/ Acronis True Image Echo Workstation http://www.acronis.com/backup-recovery/advanced-workstation/index.html Phoenix cme PC Edition http://www.phoenix.com/pages/support--3 Note: The following procedures cover basic steps for running the True Image Echo Workstation and Phoenix cme PC Edition applications, respectively. For more definitive documentation refer to their aforementioned documentation resources. 919020 RevA 1

Instructions Running the Acronis True Image Echo Workstation Recovery Application 1. Connect a network cable to the LAN port on the rear of the oscilloscope if you intend to activate windows through the Internet. 2. Connect a keyboard and a mouse to the oscilloscope. 3. Apply power to the oscilloscope. 4. As soon as the Starting Acronis Loader... Press F11 for Acronis Startup Recovery Manager message appears on the screen, press the F11 key until the recovery software logo appears momentarily. The Acronis True Image Echo Workstation main window is displayed. Note: Do not press F11 before you see the Starting Acronis Loader message or you will enter the MB boot sequence selection. 5. Select Recovery from the Main Menu. The Restore Data Wizard opens. 6. Click Next on the Welcome page. 7. On the Backup Archive Selection page, you choose the zone where the recovery partition is located. Choose Acronis Secure Zone (this is where the recovery data is located on your oscilloscope) and click Next. 8. On the Backup Date Selection page, choose the date when the backup was created and to which state you want to revert your system and click Next. 9. On the Restoration Type Selection page, select Restore disks or partitions and click Next. 10. On the Partition or Disk to Restore page, select SYSTEM (C:) as the source and click Next. 11. On the Restored Partition Type page, select Active and click Next. Note: If a window appears asking if you want to buy Acronis products, click Do not show this message again and click OK. 12. The Restored Partition Size page displays the Partition size for the restoration. Nothing needs to be changed, simply click Next. 13. On the Next Selection page, you will be asked if you want to restore another partition or hard disk drive. Select No, I do not and click Next. 14. The Restoration Options page displays additional options, such as what to do after the restoration is complete and error handling. Simply click Next to use the default selections. 15. A summary window is displayed indicating that Acronis True Image is ready to proceed with the recovery of the C: partition. Click Proceed to start the recovery process. Note: This takes approximately 4 to 15 minutes depending on the version of Operating system that is being restored. The progress is displayed on the screen 16. Once the restoration is complete, an Information window is displayed indicating that the Data was successfully restored. Click OK. 17. Click Operations Exit. The oscilloscope will restart and begin installing the required software. A message is displayed asking if you want to install Microsoft Office PowerPoint Viewer. 18. Click Yes to install PowerPoint Viewer. The InsallShield Wizard for Adobe Flash Player opens. 19. To install Adobe Flash Player, click Install and then Finish. The X-Stream software installer screen appears. 20. Click Next to continue. The License Agreement page is displayed. 21. Click I Agree. The Choose Components page is displayed. 22. Select all X-Stream components and click Install. Note: A Windows Security window may be displayed indicating that Windows can't verify the publisher of this driver software. Choose Install this driver software anyway and then click Install. 2 919020 RevA

23. When the X-Stream installation is completed, reboot the oscilloscope. Oscilloscope System Recovery Tools and Procedures Note: Now you must activate Windows using an Internet connection to the Microsoft Web site or by telephone. When activating, have the Windows Product Key number handy (it is affixed to the rear of the oscilloscope). At this point, proceed to the Restarting the Application section at the end of this topic. Running the Phoenix Recovery Application 1. Connect a network cable to the LAN port on the rear of the oscilloscope if you intend to activate windows through the Internet. 2. Connect a keyboard and a mouse to the oscilloscope. 3. Apply power to the oscilloscope. 4. As soon as the LeCroy logo appears on the screen, press and hold down the F4 key until the recovery software logo appears momentarily: 5. Then, the cme console End User License Agreement is shown. Read the agreement, and click Accept: 919020 RevA 3

Instructions 6. The Phoenix cme Console main page is displayed. Click the section of the screen labeled Click here to start recover. 7. The FirstWare Recover splash screen is shown momentarily: 4 919020 RevA

Oscilloscope System Recovery Tools and Procedures 8. The recovery starts, and the FirstWare Progress screen is displayed. No further selections are required. The recovery takes about 10 minutes. Note: The screen goes blank on occasion for prolonged periods. This is normal and is not an indication of any malfunctioning of the recovery process. 9. After the recovery is completed, the X-Stream software installer screen appears. Click Next to continue: 10. When the X-Stream installation is completed, reboot the oscilloscope (as follows). 919020 RevA 5

Instructions Windows Activation after System Recovery Note: After system recovery, you must now activate Windows by Internet connection to Microsoft s Web site or by telephone. When activating, have the Windows Product Key number handy (it is affixed to either the rear or side panel of your instrument). Restarting the Application Upon initial power-up, the oscilloscope automatically loads the instrument application software. If you exit the application and want to reload it, touch the shortcut icon on the desktop: When the application is minimized, you can maximize it by touching the appropriate task bar or desktop icon (the following icons are for WaveMaster, WavePro, and WaveSurfer, respectively): Restarting the Operating System If you need to restart the Windows operating system, reboot the oscilloscope by pressing and holding in the power switch for 10 seconds, then turning the power on again. 6 919020 RevA

Oscilloscope System Recovery Tools and Procedures LeCroy Corporation 700 Chestnut Ridge Road Chestnut Ridge, NY, 10977-6499 Tel: (845) 578-6020, Fax: (845) 578 5985 Internet: www.lecroy.com 2010 by LeCroy Corporation. All rights reserved. LeCroy and other product or brand names are trademarks or requested trademarks of their respective holders. Information in this publication supersedes all earlier versions. Specifications are subject to change without notice. 919020 RevA 919020 RevA 7