DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com



Similar documents
GPRS M-Bus Master. User Manual. An Economical and Practical Solution For Remote Automactic M-Bus Smart Meter Reading by GPRS In The Worldwide!

GSM Gate Opener GSM Remote Switch RTU5015. User Manual. Ver 1.3 Date Issued: All rights reserved by King Pigeon Hi-Tech. Co., Ltd.

Application/Connection Examples

GSM Gate Opener GSM Remote Switch RTU5015 User Manual

ZC-24DO CANopen I/O Module: 24 Digital Outputs

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Solarcheck string monitoring. User manual

GSM SMS Controller GSM SMS Alarm Unit S130 S140 S150. User Manual

s!nus-elektrotechnikai bt. Industrial IT & Automation

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

Rack mounted telephone- and leased line modem for industrial applications

GSM SMS IR CONTROLLER

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

WEB log. Device connection plans

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

HAC-LM Series Low Power Data Radio Module

Quick Connect. quick - simple - efficient.

Telephone- and leased line modem for industrial applications TD-36

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Temp. & humidity Transmitter Instructions

2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode:

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

TX2123 RS485 TO ETHERNET ADAPTOR

Electronic Control Devices The European Product Catalogue 2007

Model: DC-A2IO Advanced HVAC Controller

Electronic Control Devices The European Product Catalogue 2007

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Modular I/O System Analog and Digital Interface Modules

s!nus-elektrotechnikai bt. Industrial IT & Automation

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

UniPi technical documentation REV 1.1

Multifunction devices

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

USER MANUAL V5.0 ST100

NC-12 Modbus Application

EDI Distributor Control Interface Wiring and Setup Instructions

RS232/422/485 BEST SOLUTION

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

DK40 Datasheet & Hardware manual Version 2

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

HAC-UM Series SHENZHEN HAC TECHNOLOGY CO., LTD. HAC-UM Series. Version 2.3C SHENZHEN HAC TELECOM TECHNOLOGY CO., LTD

Alcalde # 1822 Col. Miraflores C.P Guadalajara, Jal. Mexico MX 01 (33) y USA 001 (619) (San Diego, CA.

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Universal Serial Bus (USB) to DH-485 Interface Converter

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

WEB log. Device connection plans

IntesisBox Modbus Server SAMSUNG Air Conditioners

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

1. SAFETY INFORMATION

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

SMS GSM Alarm Messenger

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

Documentation. M-Bus 130-mbx

Intelligent RS-485 I/O expansion unit: RU-87Pn Series

GPS NTP Time Server for Intranet Networks DIN RAIL Version

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Modbus Server SAMSUNG Air Conditioners

Vibration analysis and monitoring Compact. Powerful. Modern technology.

ADM1TE 5/30A DIN rail single phase two wire energy meter

RFID MODULE Mifare Reader / Writer SL031 User Manual Version 2.7 Nov 2012 StrongLink

NX safety stand-alone

Serial over Ethernet Device Server. User s Manual

Operating Temperature: 0 o to 70 o C mm (0.89 inches) ... Incremental Front View

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. Version 3.0

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

KOM200. Industrial Serial to Fiber Media Converter. User s Manual

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

USB to serial chip CH340

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

Fieldbus slave modules with I/Os, DIO

Indoor / Outdoor Antenna

CMC-DN01 DeviceNet Slave Communication Card Operation Manual

Vibration Monitoring System Adash 3600

Industrial Bar Code Scanners

IntesisBox Modbus Server Fidelio IP

TPM Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal

DMX2PWM 9 Channel Dimmer Setup Manual

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

7.7 Ethernet Communication (AFPX-COM5)

KSH-3000-MI. Swipe Card Reader. ( Magnetic / IC Card two in One Reader ) Revision Reason Date V

Table of Contents. Creating a VC1000 Network... 3

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

GTS-4E Hardware User Manual. Version: V1.1.0 Date:

CPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output

38 Series - Relay interface modules A

Transcription:

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com This handbook has been designed as a guide to the installation and operation of King Pigeon Hi-Tech.Co.,Ltd DAM series. Statements contained in the handbook are general guidelines only and in no way are designed to supersede the instructions contained with other products. We recommend that the advice of a registered electrician be sought before any Installation work commences. King Pigeon Hi-Tech.Co., Ltd, its employees and distributors, accept no liability for any loss or damage including consequential damage due to reliance on any material contained in this handbook. King Pigeon Hi-Tech.Co., Ltd, its employees and distributors, accept no liability for GSM Network upgrading or SIMCard upgrading due to the technology specifications contained in this handbook.

1. Brief instruction The DAM124 is for monitoring 4 digital inputs(can be used as pulse counter), 8 analog inputs, controlling 4 triode drivable digital output(50v/100ma, can be TTL or Pulse output). It supports Modbus RTU Protocol over RS485 serial port. Powered up by 10~30VDC. The DAM124 is used widely in industrial automation control systems. E.g.: Base Transceiver Station, diesel generator rooms, engine room, transformer substations, telecommunication equipment rooms, power supply systems and so on. The DAM124 is an industrial class, high reliability, low-power consumption, high stability and high precision data acquisition module. The DAM124 with fire retardant shell, standard 35mm DIN rail makes it easy to install in fields. Tips: King Pigeon Hi-Tech.Co.,Ltd not only provides competitive prices, excellent quality but also helps customers to solve technical problems, improve quality, reduce extra costs, and assist customers to become more competitive. If our existing modules cannot meet your requirements, we also design and manufacture new models / products according to buyer's request. Any of your requirements is always welcome! 2. Mainly Features 16-bit resolution high precision AD acquisition and data processing techniques; 4 digital input, Dry contact or Wet contact(logic:0~0.5v or NC=0, +3~30V or NO=1, input voltage range: 0~30V, Input Max. voltage range: -10~40V), can be used as pulse counter input: counter sampling frequency:1khz, impulse width of high or low level must >1mS, Max. counter value is 4 bytes: FFFFFFFFH; 8 analog input, can be 0~20mA,4~20mA,0~5V,0~10V; 4 drivable digital output(triode, not relay inside, 50V/100mA), can be setup as TTL output or Pulse output(impulse width 0.1~20S); Wide range power supply with reverse polarity connection protection; Modbus RTU Protocol; ESD Protection circuit for RS485 serial port; Using industrial-grade chips; Built-in watchdog ensure it reliability; Lightning protection ensure it stability; LEDs for status indication makes it easy to program in filed. 3. Specifications Items Specifications Rated Power Input 10~30VDC(Peak Voltage must 40V) Power Consumption Typically 3W Communication Protocol Modbus RTU Modbus Address 1~247 Data Format n,8,1; e,8,1; o,8,1 or n,8,2 Communication Interface RS485 Baud Rate 1200, 2400, 4800, 9600, 19200, 38400Bps K i n g P i g e o n H i - T e c h. C o. L t d. w w w. G S M - M 2 M. c o m 2 / 6

4. Installation A Professional Industrial Automation & Digital Input 8 digital input, Dry contact or Wet contact Drivable Output 4 drivable digital output(triode, not relay inside,50v/100ma) Analog Input Default: 4~20mA, optional: 0~20mA, 0~5V, 0~10V Update Period 0.25~2S Measurement Precision ±0.1%FS Input Resistance Analog channel: Voltage:>1KΩ, current 150Ω Overload Capacity 1.2 times can sustained,3 times voltage can last 1 second. Isolated Type Digital Input / power / RS485 Serial port / drivable output use the same GND, no isolated. Withstand Tests Input /Output /Shell: 2000VAC/min.; 500VDC>100 MΩ Installation Type 35mm DIN Rail Operation Temperature -20~70 ; Storage Temperature -40~85 ; Relative Humidity 5~95%RH.;(at -40, non condensate) Altitude 0~3000m Temperature Drift 100ppm/ Dimension 118 72 59mm mm(hxwxd) Net Weight 160g. 4.1 Physical Outlet of the DAM124 4.1.1 Install The DAM124 Please install the DAM124 to the DIN Rail 35mm, then connect the wires. Wiring Tips: 1) Connecting the block terminal to the DAM124; 2) Using the 0.2~3.3mm²wires to connection, please remove the insulator from each wire end about 6mm; 3) Using the screw to fix the wires to the block terminal, the force is 0.56~0.79N m. 4.1.2 Definition of the PINs PIN Definition Description PIN Definition Description 1 V+ Power positive 24 GND Analog Negative (GND) 2 GND Power Negative 23 AI8 8 th Analog input positive K i n g P i g e o n H i - T e c h. C o. L t d. w w w. G S M - M 2 M. c o m 3 / 6

3 NC Useless 22 AI7 7 th Analog input positive 4 A+ RS485 A+ 21 AI6 6 th Analog input positive 5 B- RS485 B- 20 AI5 5 th Analog input positive 6 GND Communication GND 19 AI4 4 th Analog input positive 7 DI1 1 st Digital input positive 18 AI3 3 rd Analog input positive 8 DI2 2 nd Digital input positive 17 AI2 2 nd Analog input positive 9 DI3 3 rd Digital input positive 16 AI1 1 st Analog input positive 10 DI4 4 th Digital input positive 15 DO4 4 th Digital Output Positive 11 DO1 1 st Digital output positive 14 DO3 3 rd Digital Output Positive 12 GND Digital Input output GND 13 DO2 2 nd Digital Output Positive 4.1.3 Wiring Diagram Typically Wiring Current Analog Input Voltage Analog input Digital Input Digital Output 4.1.4 Testing the DAM124 1. Please reference the abovementioned wiring connection to finished the connection. Please only switch on the DAM124 before you re sure the connections are correct. After connected the power, the RUN LED indicator will flick according to refresh time that you set. Default is Address 1, baud rate 9600bps, data format: n,8,1, refresh time:720ms. K i n g P i g e o n H i - T e c h. C o. L t d. w w w. G S M - M 2 M. c o m 4 / 6

The user can change the settings by our configurator. 2. Connect to RS485 network The host should provide the RS485 interface, if no RS485 port, please use the RS232 to RS485 converter. We recommend the user use the isolated RS485 to improve the reliability. In the RS485 network, all of the A+ should connect together, and the B- connect together,too. Also, the GND should connect together then connect to the Communication GND. The RS-485 network usually allow to connect maximum 32 device.if the device more than 32, then please use the RS485 repeater to extend it. The RS-485 network should use the shield twist cable, the shield should connect to GND independently. The RS485 network communication distance maximum is 1200m, when the communication baud rate is high will cause the communication distance short, in this case, please use the RS485 repeater. At the end of the RS485 network, if the communication quality is not good then usually should connect a 120~300Ω/0.25W termination resistors. If the communication quality is good then no need to connect this resistor. 3. Refresh the data The user can setup the analog input refresh time, default is 0.72S, the range is 0.12S~2.4S, the refresh time longer then the reliability of the data is better. Recommend refresh time is 0.6~1.2S. 5.Modbus register tables The register is used for the Modbus RTU protocol. Table 1:Digital output definition, function code 01/05/0F 0000H DO1 1 st digital output:=1 triode close,=0 open. 0001H DO2 2 nd digital output:=1 triode close,=0 open. 0002H DO3 3 rd digital output:=1 triode close,=0 open. 0003H DO4 4 th digital output:=1 triode close,=0 open. Table 2: Digital Input definition, function code 02 0000H DI1 1 st digital input,=0 short or close,=1 Open or no signal. 0001H DI2 2 nd digital input,=0 short or close,=1 Open or no signal. 0003H DI3 3 rd digital input,=0 short or close,=1 Open or no signal. 0004H DI4 4 th digital input,=0 short or close,=1 Open or no signal. Table 3: Input register, function code 04,RD Remark 0000H AI1 1 st Analog input Analog input, no symbol. 0001H AI2 2 nd Analog input 0~10000 correspond to 0~full range; 0002H AI3 3 rd Analog input Real valve=data/10000*range AI0 0003H AI4 4 th Analog input Unit: ma or V. 0004H AI5 5 th Analog input 0005H AI6 6 th Analog input 0006H AI7 7 th Analog input 0007H AI8 8 th Analog input 0008H K i n g P i g e o n H i - T e c h. C o. L t d. w w w. G S M - M 2 M. c o m 5 / 6

0010H DI DI input status Low 4 bit is the digital input status: BIT3~0 correspond to DI4~DI1. 0011H DO DO output status Low 4 bit is the digital output status: BIT3~0 correspond to DO4~DO1. Table 4: Holding register definition, function code:03/06/10h 0000H Mod Device Model 0001H Ver Version 0002H AI0 Analog input range,20 correspond to 20mA. 0003H 0008H Abovementioned only can read, below mentioned can read and write. 000BH ADDR Device Address; 1~247;0 is the broadcast address. 000CH COM1 Com setting: high-order 8 bytes reserved. The highest 2 bytes in the low-order bytes is data format: 00 stands for 10bits,equal to n,8,1; 01 stands for 11bits, equal to parity is even e,8,1; 10 stands for 11bits,parity is odd, o,8,1; 11stands for 11 bits, non parity, 2 is stop bit,n,8,2; The low 4 bytes is baud rate: 03~08 stands for 1200~38400BPS; default is 6, equal to 9600bps. 000DH 0013H Ts The low 8 bytes is the refresh time: 0.12S~2.4S correspond to 1~20, default is 10 equal to 0.72S, 1 equal to 0.12S. 0014H DO1-PUL DO1 Digital output type,bit15=1stands for pulse output,=0stands for level output; low 8 bytes is pulse duration time:1~250 correspond to 0.1~25.0S; default is 10. 0015H DO2-PUL DO2 Digital output type, definition is the same as D01. 0016H DO3-PUL DO3 Digital output type, definition is the same as D01. 0017H DO4-PUL DO4 Digital output type, definition is the same as D01. 0018H Table 5: Counter Holding register definition, function code: 03/06/10H 0030H DI1_CntH 1 st Digital input 32bit counter high 16 bit. 0031H DI1_CntL 1 st Digital input 32bit counter low 16 bit. 0032H DI2_CntH 2 nd Digital input 32bit counter high 16 bit. 0033H DI2_CntL 2 nd Digital input 32bit counter low 16 bit. 0034H DI3_CntH 3 rd Digital input 32bit counter high 16 bit. 0035H DI3_CntL 3 rd Digital input 32bit counter low 16 bit. 0036H DI4_CntH 4 th Digital input 32bit counter high 16 bit. 0037H DI4_CntL 4 th Digital input 32bit counter low 16 bit. More about Modbus RTU protocol please reference to other documents. The End! Any questions please help to contact us feel free. K i n g P i g e o n H i - T e c h. C o. L t d. w w w. G S M - M 2 M. c o m 6 / 6