Pioneer DreamMicro. Blade Server S75 Series



Similar documents
Optimized dual-use server and high-end workstation performance

Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server

Fujitsu PRIMERGY BX600 S3 Blade Server

Cisco Unified Computing System Hardware

Primergy Blade Server

A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing.

APACHE HADOOP PLATFORM HARDWARE INFRASTRUCTURE SOLUTIONS

New levels of efficiency and optimized design. The latest Intel CPUs. 2+1 expandability in UP 1U

High Performance 1U Server. High Performance 1U Storage Server. Front Parallel CPU Design features better cooling

High Performance 2U Storage Server. Mass Storage Capacity in a 2U Chassis

Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server

5520UR 00UR 00UR 625UR 625URSAS 00UR URBRP 600URLX 625URLX

MESOS CB220. Cluster-in-a-Box. Network Storage Appliance. A Simple and Smart Way to Converged Storage with QCT MESOS CB220

Data Sheet Fujitsu PRIMERGY BX900 S1 Blade Server

OpenVMS Support for c-class Blades

Data Sheet Fujitsu PRIMERGY BX600 S3 Blade Server

FUJITSU Enterprise Product & Solution Facts

How To Configure Your Computer With A Microsoft X86 V3.2 (X86) And X86 (Xo) (Xos) (Powerbook) (For Microsoft) (Microsoft) And Zilog (X

Fujitsu PRIMERGY Servers Portfolio

Fujitsu PRIMERGY Servers Portfolio

PCI Express Impact on Storage Architectures and Future Data Centers. Ron Emerick, Oracle Corporation

NEC EXPRESS5800/R320c-E4 Configuration Guide

Application Server Platform Architecture. IEI Application Server Platform for Communication Appliance

Servers, Clients. Displaying max. 60 cameras at the same time Recording max. 80 cameras Server-side VCA Desktop or rackmount form factor

TS500-E5. Configuration Guide

Highly Scalable Server for Many Possible Uses. MAXDATA PLATINUM Server 3200 I

EDUCATION. PCI Express, InfiniBand and Storage Ron Emerick, Sun Microsystems Paul Millard, Xyratex Corporation

How To Buy An Fujitsu Primergy Bx400 S1 Blade Server

Network Security Appliance. Overview Performance Platform Mainstream Platform Desktop Platform Industrial Firewall

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure

HP Cloudline Overview

VTrak SATA RAID Storage System

Power Redundancy. I/O Connectivity Blade Compatibility KVM Support

Form release date 2007/01/02

SUN/Oracle WSCA Price List. Please call (877) SUN-LATG (877) (504) Or Fax (504) Or

HP BladeSystem - die neue c-class Generation

Data Sheet Fujitsu PRIMERGY CX122 S1 Cloud server unit for PRIMERGY CX1000

PCI Express and Storage. Ron Emerick, Sun Microsystems

Arrow ECS sp. z o.o. Oracle Partner Academy training environment with Oracle Virtualization. Oracle Partner HUB

NEC Express5800/R120f-2M System Configuration Guide

U.S. Product Specifications Reference PSREF. Version 483, December ThinkServer Servers. Visit for the latest version

UCS M-Series Modular Servers

The BENEFITS of a Storage Bridge Bay Solution

Scout 1U Rackmount Computer

HUAWEI Tecal E6000 Blade Server

1. Specifiers may alternately wish to include this specification in the following sections:

1U µtca.4 Chassis with 2 AMC Slots, PCIe Gen 3 VT816

Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server

Appendix 3. Specifications for e-portal

Grid on Blades. Basil Smith 7/2/ IBM Corporation

LaCie 12big Rack Network

power rid B ge C o m p u t e r

Intel Server Chassis P4304XXSHCN/P4304XXSFCN/P4000XXSFDR

The Future of Computing Cisco Unified Computing System. Markus Kunstmann Channels Systems Engineer

System x3650 Type 7979

HPC Update: Engagement Model

» Communication Rack Mount Servers «

PCI Express Impact on Storage Architectures. Ron Emerick, Sun Microsystems

Headline in Arial Bold 30pt. The Need For Speed. Rick Reid Principal Engineer SGI

Terms of Reference Microsoft Exchange and Domain Controller/ AD implementation

Data Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade

Up to 4 PCI-E SSDs Four or Two Hot-Pluggable Nodes in 2U

SUN FIRE X4150, X4250, AND X4450 SERVER ARCHITECTURE. Breakthrough Density Using Sun and Intel Technology

QuickSpecs. HP Integrity cx2620 Server. Overview

Easily Upgrade to the Quad Core CPU without Additional Mechanism Rebuilding Costs

Cisco MCS 7845-I2 Unified Communications Manager Appliance

Server Bandwidth Scenarios Signposts for 40G/100G Server Connections

SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION

C460 M4 Flexible Compute for SAP HANA Landscapes. Judy Lee Released: April, 2015

Data Sheet FUJITSU Server PRIMEQUEST 2400E Mission Critical

Chapter 5 Cubix XP4 Blade Server

Intel Xeon Processor E5-2600

CG2100 Carrier Grade Server. Document Revision 1.2

PCI Express Impact on Storage Architectures and Future Data Centers. Ron Emerick, Oracle Corporation

Cisco Unified Communications on the Cisco Unified Computing System

Tipos de Máquinas. 1. Overview x3550 M2. Features X550M2

System Configuration and Order-information Guide ECONEL 100 S2. March 2009

Data Sheet FUJITSU Server PRIMERGY RX100 S8 Mono socket 1U rack server

Data Sheet FUJITSU Server PRIMERGY TX100 S3p Tower Server

præsentation oktober 2011

HUAWEI TECHNOLOGIES CO., LTD. HUAWEI FusionServer X6800 Data Center Server

Data Sheet PRIMERGY TX200 S4. Dual Socket Quad-Core Intel Xeon Server - Cost-efficient expansion options and failsafe operation

Sun Microsystems Special Promotions for Education and Research January 9, 2007

Data Sheet FUJITSU Server PRIMEQUEST 2800B Business Critical

PRICE LIST Euros: CY 2011 Q4 IT PLATFORM SOLUTIONS

Acer AN1600 F1 Network Storage System Specifications. Product Front view

NEC EXPRESS5800/R320d-E4 Configuration Guide

Data Sheet FUJITSU Server PRIMERGY RX1330 M1 rack server

Video Monitoring and Log System

PCIE High performance dual core Pentium D with SATAII Raid 0,1,5,10 function support!

HUAWEI Tecal E9000 Converged Infrastructure Blade Server

NEC Express5800/T110f-E System Configuration Guide

Fujitsu PRIMERGY BX920 S2 Dual-Socket Server

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

NEC Micro Modular Server Introduction. NEC November 18,2014

Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure

DCS Data and communication server

Personal Systems Reference

Cisco UCS C24 M3 Server

AP480-S Motherboard layout reference Contents

Transcription:

Pioneer DreamMicro Blade Server S75 Series

Advantage of Blade Server? Easy Maintenance Hot Swappable High Availability Redundant Architecture Space Saving Cableless Rack Mount Server Blade Server

Pioneer Blade Server 7U chassis 10 Server Blades Intel Server Blade No Single Point Failure Redundant Power, Cooling, CMM, I/O, etc Multiple I/O Technologies Support GbE, FC, SAS Expander Switch and Pass-Through Solutions Storage Solutions SAN, NAS, DAS Integrated KVM Switch Entry KVM, Adv KVM (G01) KVM over-ip Out-Of-Band Chassis Management Power Supply Unit: N+1 (2100W for each) Mid-plane: 100% Passive

Front View 12.07 H 28.93 D 17.56 W One System Supports Up to 10 Server Blades

Rear View Fabric 2, Daughter Board Fabric 1, Onboard I/O 1 I/O 0 Switch Switch FC/GbE 10GbE I/O 3 I/O 2 FC/GbE 10GbE MMB Slave KVM Basic/Adv. PSU 2100W N+1 Redundant MMB Master

Structure The View of Chassis Side Handle Use two rear handle to remove rear module for maintain Middle plane

Structure The View of Inside Board Connecting FAN BD X2 GbE Switch Module X2 GbE Pass-Through Module X2 FC Pass-Through Module X2 PDB X2 Power Supply N+1 (2100W) MGMT Module X2 KVM BD

Mid-plane Placement

S75A/B Server Blade FBDIMM Socket 2.5 HDD CPU 2.5 HDD NIC with TOE iscsi Storage board options (next page for the details) Daughter Board Socket

S75A CPU Blade Specification Description CPU Chipset PCI Slots Daughter Card MB Form Factor VGA System Memory I/O Port (to Mid-Plane) I/O Port (Front) GbE LOM Drive Controller BMC Controller Power Supply Intel Xeon Dempsey, Woodcrest, Clovertown LGA771 Intel 5000P (Blackford +ESB2) One PCI-E (x4) or One PCI-X on front side Two PCI-E (x4) or One PCI-X 13.1 inches X 10.5 inches, 10 Layers ATI RN50 w/ VRAM 16MB 8 x DDR2-533/667 FBD (Up to 32GB) Two Serdes LAN, VGA, COM, One USB, Two PS2 Two USB2.0, One VGA, Four LED(NIC, Power, Event, ID), Two SW (Power, ID) Two BCM5708S Two SATAII Ports by ESB2 or Two SAS Ports by SAS board (LSI1068) H8 (HD64F2168) From Rear side Redundancy Power Supply (Max 420W/Per Blade) HDD Two SAS/SATA 3.0G RoHS Compliance Yes

S75A/B CPU Blade Block Diagram

S75A/B CPU Blade Placement

Redundancy MMB and KVM Module 10 x server blades Blade Server 9 Blade Server 10 BMC BMC Blade Server 1 BMC 1 3 MMB-Slave A SCSI Dummy Master/Salve MMB Modules 0 2 MMB A-KVMB MMB-Master KVM Passive Mid-plane

MMB1/2 Interconnect Master Manager Slave Manager Switch A HB HB_P2S HB Monitor HB_S2P Monitor Switch B Switch C Switch D Isolations RX/TX Isolations Remote KVM I 2 C Bus TX/RX Middle Plane BMC BMC BMC BMC Fan Module x 2 Redundant Power supply Module x 4 CPU Blade 1 CPU Blade 2 CPU Blade 9 CPU Blade 10

Architecture for Low Speed Interconnect Master Manager Slave Manager HB Monitor HB_P2S HB_S2P HB Monitor Switch 1 Switch 4 KVM Board Isolatio ns RX/TX Isolatio ns Middle Plane I 2 C 2 Chassis FRU SW RX/TX Blade RX/TX Local Bus I 2 C 1 Remote KVM Board KVM signal System Temperature USB 2.0 USB 2.0 Rear Fan FC Pass 1 FC Pass 2 CPU Temperature and Voltage on Blade Module H8 H8 Slave I 2 C Channel on CPU Blade CPU Blade 1... CPU Blade 10

Block Diagram of I 2 C Channel 1 Master Manager Slave Manager Zircon I 2 C_1 Zircon I 2 C_1 I 2 C HUB I 2 C HUB Isolations Isolations Middle Plane I 2 C_H4 I 2 C_H3 Remote KVM board I 2 C_H1 I 2 C_H2 CPU Blade Switch Blade 1 2 3 4 5 1 6 7 8 9 10 2 3 4

Block Diagram of I 2 C Channel 2 Master Manager Master Manager Zircon I 2 C_2 Isolations Server MGM EEPROM Middle Plane Zircon I 2 C_2 Isolations Server MGM EEPROM Middle Plane I 2 C_PWR0,1 Rear Fan 0 I 2 C_PWR2,3 Rear Fan 1 I 2 C_Chassis Ambient Temperature Sensor Chassis FRU PDB PDB FC Pass 0 FC Pass 1 PWR0,1 Rear Fan Module 0 PWR2,3 Rear Fan Module 1

Dual Redundant Fabrics Fabric 1 : From On-Board to I/O 0 and I/O 1 Slots Fabric 2 : From Optional Daughter Card to I/O 2 and I/O 3 Slots 10 x blades... Blade 1 0 2 3 4 I/O 0 I/O4 I/O2 Fabric 1 Uplink Fabric 2 Uplink Blade 8 Blade 9 0 0 2 I/O1 Fabric 1 Uplink Blade 10 On Board 0 1 2 2 3 4 3 4 I/O3 Fabric 2 Uplink PCI Adaptor 3 Passive Mid-plane

Front I/O Modules (optional) SAS Base Board SATA Bridge Board SAS Base Board MB SATA Bridge Board MB SAS Base Board + PCI-X Riser SAS Base Board + PCI-E Riser PCI-X Riser Card PCI Tray Bracket Assy SAS Base Board PCI-X Riser Card SAS Base Board

Rear I/O Modules (Optional) Management Blade (MMB) Support Out-f-band Management Function External Interface Through 10/100 LAN or RS232 Basic KVM Module(K01) KVM Direct Interface Through Y-cable Advance KVM Module (G01) KVM over IP (10/100 LAN) Interface

Rear I/O Modules (Optional) GbE Pass-Through Module 10-Channel Internal SerDes Interface 10-Channel External RJ45 Interface FC Pass-Through Module 10-Channel Internal Interface 10 External SFP Interface 10Gb Lan port Switch 10-Channel Internal SerDes Interface 6-Channel External RJ45 Interface CX4 & XFP External 10GbE Interface

PCI Daughter Card (Optional) Installed on Server board Host Interface One PCI-X 64-bit/133MHz bus One PCI-E (x8) or two PCI-E (x4) buses PCI-E Support 2.5Gb/s I/O interface Two I/O channels I/O channel supports 3.125Gb/s

Why Pioneer Blade Server? Benefit Good Cooling and Power System Scalability High MTBF - 100% Passive Mid-plane Lower Cost and High Quality KVM over IP Supported No Interoperability Issue