How To Use An Ams 5812 Pressure Sensor With A Usb Starter Kit



Similar documents
Installing the Gerber P2C Plotter USB Driver

ISK 200 Driver Installation

DS2438EVKIT+ Smart Battery Monitor Evaluation Kit

ic-mq EVAL MQ1D EVALUATION BOARD DESCRIPTION

Ash Capture Control User Guide

The following items are trademarks or registered trademarks of Kaba Mas in the United States and/or other countries. GITCON

MAX6683 Evaluation System/Evaluation Kit

Using the Communication Ports on the DG-700 and DG-500 Digital Pressure Gauges

ZMD31050 Advanced Differential Sensor Signal Conditioner

JVC Monitor Calibration 2 User's Guide

INDEX. Trademarks All name and product s trademarks mentioned below are the property of their respective companies.

RC2200DK Demonstration Kit User Manual

ISP Engineering Kit Model 300

WinLIN Setup and Operation:

EVAL-UFDC-1/UFDC-1M-16

HP-1000 Powerline USB Adapter

HP-1000 Powerline Ethernet Adapter

Real Time Clock USB Evaluation Board V3.0

DeviceNet Bus Software Help for Programming an Allen Bradley Control System

Installation Guide. Wyse C Class Conversion to WES7. Wyse USB Firmware Tool TM Release Issue: PN: L Rev. B

Keep it Simple Timing

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

STIM202 Evaluation Kit

User Guide Reflow Toaster Oven Controller

Installing S500 Power Monitor Software and LabVIEW Run-time Engine

USBSPYDER08 Discovery Kit for Freescale MC9RS08KA, MC9S08QD and MC9S08QG Microcontrollers User s Manual

Fiber Optic Monitor and Control Evaluation Kit

GSM Interfacing Board

PCAN-USB CAN Interface for USB. User Manual. Document version ( )

Transmitter Interface Program

MPLAB IDE 64-Bit USB Device Drivers Installation

Configure Inverter output for two utility settings, (1)120V/60Hz, (2)220V/50Hz

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

EPSON Stylus. Start Here

PHD User Manual. Table of Contents

Bluetooth HC-06 with serial port module Easy guide

Config software for D2 systems USER S MANUAL

Introducing AVR Dragon

Digital Photo Bank / Portable HDD Pan Ocean E350 User Manual

Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts

Guide to Installing BBL Crystal MIND on Windows 7

SOFTWARE INSTALLATION INSTRUCTIONS

PCAN-MicroMod Universal I/O Module with CAN Interface. User Manual. Document version ( )

USB External Hard Disk Drive

Health Monitoring Demo for ice40 Ultra Wearable Development Platform User Guide. UG103 Version 1.0, September 2015

M68EVB908QL4 Development Board for Motorola MC68HC908QL4

2013 CNS Geiger Kit Instructions read me Page 1 of 5

Lab Experiment 1: The LPC 2148 Education Board

Table of Contents. 1. Overview Materials Required System Requirements User Mode Installation Instructions..

PM1122 INT DIGITAL INTERFACE REMOTE

SKP16C62P Tutorial 1 Software Development Process using HEW. Renesas Technology America Inc.

CANON FAX L360 SOFTWARE MANUAL

Installation of the USB to RS 485 Converter

Product information and manual for SensLab BT-Adapter (Model type: BT060721) for wireless data transfer of measurement data of Lactate Scout-handheld

Capacitive Touch Lab. Renesas Capacitive Touch Lab R8C/36T-A Family

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Programming the On-Chip Flash on a phycore-xc161 phycore-xc167

Iridium Extreme TM Satellite Phone. Data Services Manual

Blastmate III and Minimate Plus USB to PC Cable (Part No. 716A3401)

USB Driver Installation for Windows XP

MARTECH SPI Tools. MARTECH SPI Tools User Manual v1.0. User Manual

DRV8312-C2-KIT How to Run Guide

Page 1 S5.5 Monitoring Software Manual Rev 1.2 for Software Ver 1.0

JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP

COMBOGARDPRO. 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS

PCAN-MicroMod Evaluation Test and Development Environment for the PCAN-MicroMod. User Manual. Document version ( )

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

PN L, Revision B, October Epic 950 TM. Master Programmer User s Guide

GE Healthcare Life Sciences UNICORN Administration and Technical Manual

User Guide. F912 Rev

TFA. KlimaLogg Pro. User Manual. Revision: 0.1

OMEGA STUDIO SOFTWARE INSTALLATION GUIDE

BIODEX. ATOMLAB 500/WIPE TEST COUNTER DATA MANAGER SOFTWARE Version 1.10 (and higher). OPERATION MANUAL

Bidirectional wireless communication using EmbedRF

Quick Start Guide. MRB-KW01 Development Platform Radio Utility Application Demo MODULAR REFERENCE BOARD

Quick Start Guide for High Voltage Solar Inverter DC-AC Board EVM. Version 1.3

SAFEPATH 4 Telephone Zone Controller

ABB solar inverters. Installation and setup instruction Aurora Manager TL software and ABB PVI-USB-RS232_485 adapter

8 Channel Status Input Panel model SIP-8

Software User Guide UG-461

Basic Use of the SPC Feature on 1100R+/H+ Testers

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

PCAN-ISA. CAN Interface for ISA. User Manual

LPR for Windows 95/98/Me/2000/XP TCP/IP Printing User s Guide. Rev. 03 (November, 2001)

Tutorial for MPLAB Starter Kit for PIC18F

T0118 T2118 T3118. Instruction Manual

3. USB DRIVER Installation of USB driver Driver for Infinity SD Data Logger. INFINITY Series Acquisition Tools Manual

An Introduction to MPLAB Integrated Development Environment

EDK 350 (868 MHz) EDK 350U (902 MHz) EnOcean Developer Kit

SA-9600 Surface Area Software Manual

SP8 Programmers 硕 飞 科 技. User's Guide. TEL: FAX: WEB:

Midland BT Updater BTUpdater Program Program file (x86) ), Midland

User Manual. Thermo Scientific Orion

Operating Instructions for the Software Fingerprint Access System FP530

ezsystem elab16m Project 1F: Alarm System (Full Project description)

Welcome to the tutorial for the MPLAB Starter Kit for dspic DSCs

3-Port FireWire 800/400 PCI Host Card

TPG MOBILE BROADBAND QUICK SETUP GUIDE

Centurion PLUS CPC4 Download Guide

User Manual DMD Configurator

Transcription:

User Guide USB Starter Kit AMS 5812 Phone:+49 (0)6131/91 0730-0 Fax: +49 (0)6131/91 073-30 Internet: E Mail: info@analogmicro.de Analog Microelectronics GmbH An der Fahrt 13, D 55124 Mainz May 2012 - Rev. 1.0

CONTENTS INTRODUCTION 3 HARDWARE 3 SOFTWARE CS5812 5 Installation 5 CS5812 user interface 5 INITIAL OPERATION 9 IMPORTANT NOTES: 10 ADDITIONAL EQUIPMENT 10 ADDITIONAL DOCUMENTS 10 May 2012 - Rev. 1.0 Page 2/10

INTRODUCTION The USB Starter Kit AMS 5812 is designed for quick and easy initial operation of AMS 5812 pressure sensors with I2C interface. Together with a standard PC with Windows operating system and the relevant software, the kit enables current digital pressure and temperature values to be read out via the AMS 5812 I2C sensor interface and to be displayed on the PC. In addition the starter kit can be used to program a second individual I2C address into each AMS 5812 pressure sensor. This customized I2C address is prerequisite for the operation of several AMS 5812 pressure sensors together on one I2C bus. This address is valid in addition to the default I2C address 78 hex. The starter kit consists of two printed circuit boards and the relevant communication software package CS5812 distributed on the starter kit CD. A Windows PC with an USB port and with operating system XP SP3 or above is required for operation. The kit will be supplied by the USB port, an external supply isn t necessary. NB: We recommend that you read the AMS 5812 sensor datasheet before putting the starter kit into operation. Hardware The starter kit hardware consists of two printed circuit boards: the communication board CB-I2C and the adapter board BB5812 with a ZIF-socket to connect one AMS 5812 sensor. Figure 1 shows the assembled kit with mounted sensor. Figure 1: USB Starter Kit AMS 5812 with connected sensor. The kit consists of a communication board CB-I2C and an adapter board BB5812, connected by a 34-pin connector. May 2012 - Rev. 1.0 Page 3/10

The CB-I2C printing circuit board provides the hardware which enables a PC with USB 2.0 port to communicate with a pressure sensor with I2C interface. The BB5812 printed circuit board provides an easy way to connect an AMS 5812 pressure sensor with the CB-I2C. The two printed circuit boards are connected by a 34 pin connector. Using a standard USB cable the USB jack on the CB-I2C is connected to a free USB-port at the PC. The PCs USB-port is used for communication and for power supply of the starter kit and the sensor; an additional supply isn t required. The connection between CB-I2C and BB5812 is realised by a 34 pin connector. A zero injection force (ZIF) socket on the BB5812 allows easy mounting and exchanging of an AMS 5812 pressure sensor. Pin 1 of the sensor is at the upper left edge of the ZIF-Socket (see Figure 1). For the internal power supply of the connected AMS 5812 by the USB Port, JP 2 on board BB5812 has to connect to position intern. Additionally the sensors supply voltage has to be chosen by the jumper JP1 on board CB-I2C (see Figure 1); for standard products of AMS 5812 series connect JP1 to 5V. For external supply of the connected AMS 5812, remove jumper JP1 and connect jumper JP2 to position extern. Subsequent the external power supply can be connected to the screw terminal block external supply connector on board BB5812. Further, for exchanging the mounted AMS5812 the sensor voltage supply can be turned off by removing JP1 and JP2. The jumper positions are summarised in table1. At the 5 pin plug connector on the BB5812 the sensor voltage supply VCC, GND, the analog output and the I2C-bus lines are connected. This plug can be used for monitoring the sensor supply voltage and further for connecting and testing sensors, which are already assembled. For safety in cause of failure an electrical isolation between the sensor and the PC was realised on the CB- IC. This avoids effectively an energy flow into the connected PC. Table 1: Jumper configuration of JP1 on CB-I2C and JP2 on BB5812 Sensor voltage Jumper position JP1 Jumper position JP2 internal supply 3.3 V central pin together with pin 3.3V central pin together with pin intern internal supply 5 V central pin together with pin 5V central pin together with pin intern external supply removed central pin together with pin extern turned off removed removed Important: If JP1 isn t removed in case of an external sensor power supply at pin VCC, the starter kit can be damaged! May 2012 - Rev. 1.0 Page 4/10

Software CS5812 The communication between the PC and the AMS 5812 pressure sensor mounted onto the starter kit is realised by means of the software package CS5812. This software is provided on the starter kit CD and runs under Windows operating systems (XP SP3 or above). Installation Before installation of the software package CS5812, please disconnect the starter kit. By executing the file CS5812_Setup.exe on the CD-ROM (must be run as an administrator), an installer is started which guides through the installation process. After the installation process is finished, the necessary files for operating the starter kit are copied to the target directory and the needed drivers are installed, too. The starter kit is now ready to use and can be connected to the PC. CS5812 user interface The software CS5812 can be run via the AMS 5812 icon in the program group AMS 5812 in the folder programs in the windows start menu. The user interface (menu) is shown in Figure 2. The menu is divided in three submenus: Communication Check, Measurement und Second I2C Address which are designed as index sheets. They will be described in detail below. Figure 2: CS5812 user interface May 2012 - Rev. 1.0 Page 5/10

Submenu Communication Check In the submenu Communication Check (see Figure 3) the type of the AMS5812, which is connected to the starter kit, has to be defined and the communication between the PC and the AMS5812 can be established and tested. Figure 3: Overview of submenu Communication Check By pushing the button Search Starter Kit (in the upper third of the submenu) the link connection between the PC and the starter kit will be initiated. If it is successful (message: Found Starter Kit ), the starter kit will be ready to use. If no starter kit was found please follow the tips given in section Initial Operation in paragraph 5. In the next step, the connected sensor type has to be selected in the drop down menu with its exact ordering code (e.g.: AMS 5812-0150-D) (see middle part in Figure 3 and Figure 4 left). To the right side the physical pressure unit can be selected by a drop down menu. The units PSI, kpa, mbar and bar are available. The pressure range of the sensor type will be shown below. In case of a custom specific version or a sensor which is not listed in the menu, the sensor type customised has to be selected and the specified minimal and maximal pressure values p min and p max have to be filled into the adequate fields below (see Figure 4 right). Figure 4: Selection of the sensor type. Left: sensor type AMS 5812-0150-D with a measuring range of 0-15 PSI Right: custom specific sensor with manually adjusted measuring rage of -5 50 PSI. NB: If the wrong sensor type is selected, sensor measurement data cannot be accurately evaluated and the displayed pressure value in physical units is wrong! May 2012 - Rev. 1.0 Page 6/10

Now, a connection to the AMS 5812 pressure sensor (mounted onto the starter kit) can be established. In the lower third of the submenu, the sensor I2C address has to be filled into the field I2C Sensor Address (standard I2C address: 78 hex ) and the Button Search Sensor has to be pushed. A message follows, whether a corresponding sensor was found or not. In case of the error message No Sensor found (after pushing the button Search Sensor ) please check the following: the connection of the two PCBs, the position of JP1, the position of the AMS 5812 in the ZIF socket and the locking of the ZIF-socket. Submenu Measurement Within the submenu Measurement (see Figure 5) it is possible to display the AMS 5812 digital pressure and temperature values. Figure 5: View on submenu Measurement. The field Sensor Type (upper third part of the submenu) displays the selected senor type with its pressure range, which was stipulated in the submenu Communication Check. With the buttons Single Shot and Continuous Measurement respectively (in the middle part of this submenu) the user can start a single measurement or a continuous measurement. In case of a continuous measurement, the time interval between the discrete measurements can be selected by the drop down menu Loop Time. The continuous measurement can be stopped by pushing the button Continuous Measurement again. By pushing the button Log Value at the right side, the readout digital values can be saved in a file. At the first time values have to be written, a windows dialog appears to assign the file name and the folder to save in. The file includes only the digital values In the lower third of the submenu the measurement data for pressure and temperature are displayed as digital (decimal) values and also as values in physical units. For a single measurement Single Shot the current measurement data available at the AMS 5812 output register is one-time read and continuously May 2012 - Rev. 1.0 Page 7/10

displayed. In case of the continuous measurement the measurement data is repeatedly read out and displayed. Submenu Second I2C Address The submenu Second I2C Address is divided into an upper and a lower part (see Figure 6): In the upper part an individual second I2C address can be programmed into the connected AMS 5812 pressure sensor 1. The second I2C address (between 00 hex and 7F hex ) has to be written in the box New I2C Address as a hexadecimal value. By pushing the button Set 2nd Address, the I2C address will be programmed to the AMS 5812 EEPROM. If the operation was successfully the field OK lights up green for a few seconds. The sensor corresponds now to the second I2C address and the standard address, too. By pushing the button Read 2nd I2C Address the user can read out the second I2C address. Figure 6 shows an example with a sensor address 33 hex. NB: If several AMS 5812 sensors are to be operated together on one I2C bus, each sensor must first be allocated its own individual second I2C address. Figure 6: View on submenu Second I2C Address The second I2C address can be programmed in the upper part. The optionally programmed second I2C address can be read out in the lower part. 1 The second I2C is additionally valid to the standard I2C address 78 hex May 2012 - Rev. 1.0 Page 8/10

INITIAL OPERATION The following steps are necessary for the starter kit initial operation setup: 1. Installation of the Software CS5812 (for details see section software) 2. Assembly starter kit First, the adapter board BB5812 for AMS 5812 sensor and the communication board CB-I2C are connected together by the 34 pin connector. Then, the sensor AMS 5812 has to be connected into the ZIF-socket on BB5812 (orientation of pin 1: see Figure 1). 3. Select sensor voltage supply (for details see section hardware): For internal power supply (AMS 5812 is supplied by the USB Port) JP 2 on board BB5812 has to be connected to position intern. Additionally the sensor supply voltage has to be chosen by the jumper JP1 on board CB-I2C to 5V. For external power supply (with additional power supply) remove jumper JP1 on board CB-I2C. Connect the external power supply to the screw terminal block external supply connector on board BB5812 and set jumper JP2 to position extern. 4. Connect the starter kit to a free USB-port at the PC by an USB cable. 5. The green LED on the communication board flashes up, when the board is detected by the PC and the drivers are loaded successfully (see Figure 1). If the green LED remains dark, the user has to look in the device manager for a new device called USB Serial Converter in the device group USB-Controller. If this doesn t exist, the user has to disconnect the starter kit from the PC by removing the USB-cable. At a reconnection, the device USB Serial Converter should appear. If not, the problem could be solved by manually executing the file Treiber_Setup.exe in the program folder of the AMS 5812 Software (e.g.: C:\program files\ams 5812). If the led remains still dark and the starter kit wasn t found, contact Analog Microelectronics GmbH for further support. 6. A voltmeter can be connected up to the 5 pin plug connector on the BB5812 if the AMS 5812 analog output signal is to be read. May 2012 - Rev. 1.0 Page 9/10

IMPORTANT NOTES 1. For changing an AMS 5812 pressure sensor while the communication board is connected to the PC, we recommend to remove the jumpers JP1 and JP2. It prevents sensor damage. 2. If JP1 won t be removed in case of external supply, the starter kit could be damaged 3. As there is no protective circuitry safeguarding against reverse polarity and overvoltage, the polarity and voltage of the external voltage supply of +5 V must be checked before voltage is applied. 4. The Communication Board CB-I2C can be used for read out pressure sensors of the series AMS 5105 and AMS 5915, too. For starting up, only the corresponding adapter boards BB5105 respectively BB5912 and the according software CS5105 respectively CS5915 are necessary. 5. The analog output signal is ratiometric to the supply voltage. If AMS 5812's specifications are to be tested, the supply voltage must be exactly 5.000 V. Any deviation in percent must be accounted for accordingly.in case of internal power supply the sensor voltage can be adjusted by the potentiometer on the CB-I2C (see Figure 1) exactly. ADDITIONAL EQUIPMENT USB-Cable 2.0, FullSpeed A-St to B-St. ADDITIONAL DOCUMENTS Data Sheet of AMS 5812 Pressure Sensor Series Analog Microelectronics GmbH reserves the right to amend any dimensions, technical data or other information contained herein without prior notification. May 2012 - Rev. 1.0 Page 10/10