Diesel Generating Set



Similar documents
P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Spark-ignited generator set

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

Atlas Copco Generators

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

Diesel Engine Driven Generators Page 1 of 6

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

DIESEL GENERATOR SETS

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

Annex-A TECHNICAL SPECIFICATION

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

Magnum Mobile Generator MMG55 Specifications

Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption

Technical Specification. Generating Set with Waukesha engine burning natural gas

How To Use A Cat Diesel Engine

Phase Modular Finally the benefits of Modular ups are for all

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

HFW-100 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

STANDBY 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts

1100 Series 1104C-44TAG2 Diesel Engine ElectropaK rpm

Specifications for Volkswagen Industrial Engine

Marine Generating Sets 3.7 to 50 kva

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption

Diesel Generator Set Model DFHC 60 Hz

APS100 Rental Generator Set Specification

Diesel Generator Set Model DGDK 60 Hz

The kva RAnge

Diesel Generator Set Model DFMB 60 Hz

How To Control A Power Command Powerplant

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

C18 ACERT Fire Pump Tier bkw/ rpm

C18 Diesel Oilfield Generator Set

Micro cogeneration. Affordable, efficient and innovative

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

Thyristor-controlled power supplies and battery chargers

OPTIONAL FEATURES 30

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

TECHNICAL SPECIFICATION TYPE ATESO ALFA

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

Electric Flow Boiler

A Single Source for all Power System Solutions

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

HEAVY DUTY STORAGE GAS

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) rpm

Stroom voor elke toepassing

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

POWER PORTABLE GENERATORS POWER. WHEN YOU NEED IT.

IGSA POWER GENERATION SYSTEMS

Vectra Caravan kW/122hp 5-speed station wagon 5 doors 1

Rental. C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES

SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction

4KVA/5KVA Parallel Installation Guide

Power Generation. Power Control PCL System Generator Set Control

CUKUROVA GENERATOR SYSTEMS

CADB and CADT-D / DI / DC Series

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

NATURAL GAS CONTINUOUS 1000 ekw 1250 kva 50 HZ 1500 RPM 400 Volts

14. Troubleshooting Guide

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

Split Controller. User Manual SM-SS-F 2009/01/04

PowerCommand iwatch 100 Remote Network Monitoring

CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual

CUKUROVA GENERATOR SYSTEMS

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

The State Fire Marshal's Office and the VDH/Office of Licensure and Certification. Generator Testing in Nursing Facilities

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

Commercial Marine Generators

Quick Connect. quick - simple - efficient.

MAJORSINE Power Inverter

CREATING POWER SOLUTIONS. 2L41C 3L41C 3L43C 4L41C 4L42C 4L43C. Hatz Diesel.

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

Exel. 715kVA kVA 700kWe kWe

BB800 Off-Grid Solar System

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

NATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Transcription:

MODEL Standby Power(50Hz) Prime Power(50Hz) 44KW /55KVA 40KW /50KVA Standard Features General Features: Engine( DCEC Cummins 4BTA3.9 -G) Radiator 40 O C max,fans are driven by belt, with safety guard 24V charge alternator Alternator(STAMFORD UCI224D), single bearing alternator IP22,insulation class H/H Absorber Dry type air filter, double fuel filter, oil filter, coolant filter Main line circuit breaker Standard control panel Two12V batteries, rack and cable Ripple flex exhaust pipe, exhaust siphone, flange, muffler User manual Generator Ratings Voltage HZ Phase P.F (COS ) Standby Amps Standby Ratings (KW/KVA ) Prime Ratings (KW/KVA) 440/254 50 3 0.8 72 44/55 40/50 415/240 50 3 0.8 76.3 44/55 40/50 400/230 50 3 0.8 79.2 44/55 40/50 380/220 50 3 0.8 83.4 44/55 40/50 Prime Power (PRP): Prime power is available for an unlimited number of annual hours in variable load application, in accordance with GB/T2820-97(eqvISO8528); A 10% overload capability is available for a period of 1 hou r within a 12-hour period of operation. Standby Power Rating (ESP): The standby power rating is applicable for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating. Sales Promises SDEC Power provides a full line of brand new and high quality products. Each and every unit is strictly factory tested. Warranty is according to our standard conditions: 12 months or 1,000 running hours, subject to the earlier one. Service and parts are available from SDEC Power or distributors in your location. Specifications may change without notice 1/5

ENGINE DATA Manufacturer / Model: Air Intake System: Fuel System: Cylinder Arrangement: DCEC Cummins 4BTA3.9-G,4-cycle Turbo, Water/Air DC AD type fuel pump 4 in line Displacement: 3.9L Bore and Stroke: 102 120(mm) Compression Ratio: 16.5 Rated RPM: Max. Standby Power at Rated RPM: Governor Type: Frequency Regulation, Steady State: Exhaust System 1500rpm 55KW/74.8HP GAC Electronic Speed Control System 1.5% Exhaust Gas Flow: 14.8m 3 /min Exhaust Temperature: 497 Max Back Pressure: Air Intake System Max Intake Restriction: Burning Capacity: Intake Flow: Fuel System 10kPa 6.2kPa 5.9m 3 /min 136m 3 /min 110%(Standby Power) Load: 9.5L/h 100%(Prime Power) Load: 8.6L/h Total Fuel Flow: Oil System 17.1L/h Total Oil Capacity: 16.4L Oil Consumption: 4g/kwh Engine Oil Tank Capacity: 14.3L Oil Pressure at Rated RPM: Cooling System Total Coolant Capacity: Thermostat: Max Water Temperature: Emissions NOx : CO: Soor : HC : 350kPa 21L 83-95 100 Specifications may change without notice 2/5

ALTERNATOR SPECIFICATION GENERAL DATA Compliance with GB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359 standards. Alternator Data Manufacturer / Type: STAMFORD / UCI224D Number of Phase: 3 Connecting Type: 3 Phase and 4 Wires, Y type connecting Number of Bearing: 1 Power Factor: 0.8 Protection Grade: IP22 Altitude: 1000m Exciter Type: Brushless, self-exciting Insulation Cl ass, Temperature Rise: H/H Telephone Influence Factor (TIF): <50 THF: <2% Voltage Regulation, Steady State: ±1% Alternator Capacity: 50 KVA Alternator Efficiencies: 88.2% Air Cooling Flow: 0.216m 3 /s GENERATING SET DATA Voltage Regulation: Voltage Regulation, Stead State: Sudden Voltage Warp (100% Sudden Reduce): Sudden Voltage Warp (100% Sudden Increase): Voltage Stable Time (100% Sudden Reduce): Voltage Stable Time (100% Sudden Increase) Frequency Reduce: Frequency Regulation, Stead State: Frequency Waving: Sudden Frequency Warp (100% Sudden Reduce): Sudden Frequency Warp (100% Sudden Increase): Frequency Recovery Time (100% Sudden Reduce) : Frequency Recovery Time (100% Sudden Increase): Noise Level: Emission Level: ±5% ±1% +25% -20% 6S 6S 5% Adjustable 1.5% 0.5% +12% -10% 5S 5S 104dB EuroⅠ Specifications may change without notice 3/5

Options Engine Fuel System Control System Heater Daily Fuel Tank Auto Control Panel Battery Charger Base Fuel Tank Remote Control Panel Water Separator Auto Transfer Switch (ATS) Control Panel Paralleling System Electricity Output Cabinet Alternator Others Data Anti Condensation Heater Rainproof Type Engine Parts Drawing List Permanent Magnet Soundproof Type Spare Parts Generator(PMG) Drop CT(For Paralleling) Trailer Type Dimension & Weight Standard Configuration (Open Type) Overall Size: 1950(mm) 750(mm) 1500(mm) Weight: 820kg With Base Fuel Tank Overall Size: 1950(mm) 750(mm) 1500(mm) Weight: 920kg Soundproof Type Overall Size: 2600(mm) 1100(mm) 1850(mm) Weight: 1445kg Specifications may change without notice 4/5

Standard Control Panel SDEC Standard Control Panel is the basic configuration for normal operation and usage, it is of some advantages such as easy to operate, various function and well protection. Operative buttons such as Turn On, Per-heat, Starting, Stop (Emergency Stop) on the panel. While malfunction occurs, control panel will stop the generator and also alarm with light or buzz. Auto Module Control Panel Automatic Control Panel is the basic configuration for nobody on duty controlling generators. This kind of panel can accept the remote start/stop signals. (Controlled by ATS) Features: adopted Czech Comap Brand auto control system, with large LCD display in English (or Chinese) to show the menu. With Auto Control Panel, generator are of various functions such as auto/manual stop (emergency stop), programmable plugs for input and output, detected data, symbols, diagram will show in the LCD, etc. Auto Remote Control Panel Automatic Remote Control Panel is based on the Auto Control Panel and add the standard communication plugs: RS232 (Modbus Communication Agreement). With Auto Remote Control Panel, it can realize remote control, remote detective, remote report by user using communicative net or center inspect and control system. Specifications may change without notice 5/5