Call for Mechanical Engineering, Electrical Engineering, and Computer Engineering Senior Design Project Proposals



Similar documents
USB-500 Series Stand-Alone, Low-Cost Data Loggers

USB-500/600 Series Low-Cost Data Loggers and Accessories

Project Plan. Project Plan. May Logging DC Wattmeter. Team Member: Advisor : Ailing Mei. Collin Christy. Andrew Kom. Client: Chongli Cai

USB-500 Series Low-Cost Data Loggers and Accessories

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

SECTION DETECTION AND ALARM

WEATHER STATION FOR SOLAR FARM MONITORING

USB-500/600 Series Low-Cost Data Loggers and Accessories

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

TruPower-Portable-500W. Solar Starter kit

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Wireless Soil Moisture and Weather Monitoring System Caipos

O C M III. Open Channel Flow Monitor

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

PD 100A. Printing data system

Electronic Control Devices The European Product Catalogue 2007

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Uninterruptible Power Supply

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

SDI Multi Sensor Module with Charger Enclosure Station Support

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Current Monitoring Kit QUICK START GUIDE

1000 Series Data Loggers PRODUCT MANUAL

Current Monitoring Kit

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since automated production systems

Wireless Data Logger Monitoring Systems

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

ACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Repeaters and Mimics Data Sheet

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

TrueAlarm Fire Alarm Systems

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Temperature & Humidity SMS Alert Controller

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Telemetry system for cathodic protection equipment of underground metal pipelines

PIEZOMETER AIRFLOW MEASURING RING

Changers Kalhuohfummi User Manual

Typical Aluminum GFM Mass Flow Meter

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Quick Start Guide RRL Radio Telemetry

Advantium 2 Plus Alarm

New XUY roller sensors

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

OWNERS MANUAL. WattsVIEW. Power Monitor Model: DC WattsVIEWTM. Models: DC Serial DC-1000 USB DC-25000

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

User manual Rev 1.3 Contents

Regards from the Team at Rheology Solutions.

PhidgetInterfaceKit 8/8/8

How To Use An Ams 5812 Pressure Sensor With A Usb Starter Kit

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

ODOT ITB Section 4: Flashers, Timers, & Software Systems Item 4-1

PRODUCT SHEET OUT1 SPECIFICATIONS

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Fanuc 0 M/T Model C Serial (RS232) Connection Guide

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

8 Channel Status Input Panel model SIP-8

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Model Number Electrical Compatibility Module Connector Type. M LL-S22 60 cell PV module MC-4 Type 2 Locking

MTII4200 level Transmitter Installation, Operation & Maintenance Instructions

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

bba - Balboa Bluetooth Audio (AMP) Installation & User Guide

IC 1101 Basic Electronic Practice for Electronics and Information Engineering

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

REMOTE MONITORING AND CONTROL SYSTEM

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

LDG DTS-4/4R Desktop Coaxial Switch / Remote

WeatherLink for Alarm Output. Introduction. Hardware Installation and Requirements. Addendum

Power Commander Power Distribution Units from Wiremold/Legrand offer

Sense. 3D Scanner. User Guide. See inside for use and safety information.

How To Sell A Talan

Product Description. Model VM 500 series [ VM508/VM508E ] Water Alarm. Telephone/Pager Alert Calls. Power Alarm. Maximum Number of Sensors

Multifunction HVAC and IAQ Meter

In-Sight Hardware specifications

WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS. John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar

Controller board and power supply for vivimat III systems

NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER

Remote Monitoring and REC 501 Control Unit Product Guide

TS93 EMR T/PT/TDE. Surface applied door closer

Loop-V4300 MINI DACS E1/ T1 CONVERTER

SMART SENSOR COLLECTION

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

MechoNet TM Network Interface (MNI) Specification Submittal

The Design of a Low-Cost and Robust Linkage Position Sensor

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Spectrum Analyzer Two models available: OGR-24 (24 GHz) and OGR-8 (8 GHz)

USB Plus+ RFID Reader Setup Guide


Solar Powered Smart Irrigation System

Product Overview. Features CHAPTER

DataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

Transcription:

Call for Mechanical Engineering, Electrical Engineering, and Computer Engineering Senior Design Project Proposals Objectives: The intent of the senior design course sequence is to teach students how to apply their math, science, and engineering knowledge to solve open-ended problems in response to needs of an external customer. These projects give students an opportunity to learn design philosophies, develop team-based designing skills, gain hands-on experience budgeting time and finances, and become proficient in oral and written communication. Student teams solve meaningful technical problems that require more time and talent than any one individual can contribute. Interdisciplinary projects can be accommodated by a common course structure. Interdisciplinary Projects: The University of Idaho encourages projects that span engineering disciplines. This gives the students an opportunity to experience the kind of multidisciplinary teamwork that they are likely to encounter in industry. This solicitation is the combined effort of Mechanical Engineering, Electrical Engineering, and Computer Engineering faculty. Some project teams will include students from two or more of these disciplines. Expectation for Students: The students are expected to have necessary technical knowledge from classes, or be able to acquire it with reasonable effort. Students starting the senior design sequence have just completed their junior classes, and most and have little or no professional industrial experience, although some may have had summer internships. Students can be expected to work on projects from 10 to 15 hours per week. Besides in-class activities, this time includes generating progress reports, preparing for design reviews, and completing formal reports. A common basis will be used to evaluate student performance across all engineering disciplines. Expectation for Sponsors: Sponsors of senior design projects should have a welldefined product in mind with well-defined requirements and constraints. The scope of projects should be suitable for teams of 3-5 students working steadily for approximately a half-year (21 weeks). Sponsors are expected to provide parts and/or financial support for material consumed in the completing the project, off-campus travel, and a contribution to upkeep of the engineering shop/laboratory infrastructure at the University of Idaho. Sponsors should also provide regular guidance and encouragement to the team so that important design issues can be resolved satisfactorily. Sponsors should not expect students to use personal funds (travel, long distance calls, etc.) to complete the project. Expectation for Projects: Every effort will be made on the part of our instructional and professional staff to insure a return on investment that meets expectations of sponsoring organizations. However, advising faculty and course instructors will not micro-manage projects, depriving student teams of ownership of project outcomes. In the event that projects are incomplete and customer satisfaction is an issue, student grades will be withheld until an acceptable solution can be produced. In the past this has required some student teams to work into the summer term, deferring start of employment.

Characteristics of a good project 1. Projects have realistic mechanical, electrical, and/or computer-based solutions involving proven technologies. 2. Projects contain multiple components, allowing concurrent design and subsequent integration into a final product with ample time for testing. 3. Projects have multiple solutions that are acceptable to the customer. Building a preexisting design does not make for a good project. 4. Projects do not require development tools or instrumentation that the College of Engineering does not possess and that the students can access easily. 5. Projects should be comparable to those given to an entry-level engineer. Projects that involve excessive proprietary material or that are in the critical path of the sponsor s business plan are to be avoided. Process for Sponsoring ME, EE and COE Senior Design Projects: 1. Submit a brief description to one of the senior design instructors listed below. For mechanical projects: Steve Beyerlein, sbeyer@uidaho.edu For electrical/computer projects: Greg Donohoe, gdonohoe@uidaho.edu 1. The instructors may iterate with sponsors for clarification or redefinition. 2. The instructors review the projects together, select the most appropriate projects, select project teams and orient teams to projects. A typical team has two to four students, and may include some students from two or more of the three participating engineering disciplines. 3. Students submit a design proposal, with work plan and schedule, to the sponsor. This may be iterative until the sponsor, instructor and design team agree on the project outcomes, work plan, and testing requirements. 4. Sponsor agrees to support the proposal and supplies necessary resources. 5. Project work begins a. Students submit regular progress reports to sponsor. b. Sponsor participates in design reviews and evaluates progress/test results. c. Students generate appropriate hardware and documentation. d. Students present their completed work at the Design Expo at the end of the spring semester. e. Students are done when project deliverables are accepted by the sponsor. Attachments: Example Project descriptions and specifications

University Of Idaho Senior Design Project For Argonne National Laboratory HEPA Filter Disassembly Station June 1, 2004 XXXX Scope Design, fabricate, and test a station capable of disassembling HEPA filters and separating the filter media from the filter frames. This activity must be performed in a remote, hot cell environment. Background The HEPA Filter Preparation Station will be located in the Remote Treatment facility processing hot cell. The Station will be used to separate the filter media from the filter frames. The radioactively contaminated HEPA filters are approximately 2 ft X 2 ft X 6 inches or1 ft thick. The frames are either steel or wood, and the media consists of aluminum separators and fiberglass paper. The HEPA Filter Preparation Station consists of a staging area table, and could consist of such equipment as a punch press and die assembly, a size-reducing device, and a receiver-can positioning assembly. A Radioactively contaminated HEPA filter would be brought into the hot cell, and any external packaging removed. The mechanism such as a punch press assembly would be used to separate the media from the frame. If the filter media contained aluminum separators, the aluminum would be separated from the media, using an automated method to be developed. A size reducing device would then be used to prepare the media for continued processing. The separated HEPA filter frames (and aluminum separators) would be re-sized and placed in the appropriate waste containers. Design Requirements The disassembly process should be designed to minimize dust generation and spread of particulate contamination on the filter media. The disassembly station must be designed to be used in a remote hot cell environment. The media sizing device must create pieces no larger than 1 x1. The process should incorporate automated separation of aluminum separators from the media.

Agriculture Field Sensor Unit Proposal Agriculture Field Sensor Unit Proposal Project Description Project An Description instrumentation package is needed to provide soil and crop data for closed loop An control instrumentation of a spatially package variable is needed center to pivot provide irrigation soil and system. crop data The for instrumentation closed loop package control is of to a be spatially solar powered variable and center radio pivot linked irrigation to a remote system. receiver The instrumentation for data acquisition and package display. is to An be alternate solar powered infrared and (IR) radio link linked for communication to a remote receiver with a palm-top for data acquisition or laptop computer and display. optional. An alternate The system infrared must (IR) be link able for to communication store 12 weeks of with environmental a palm-top or data laptop including computer a time is optional. stamp that The is system Y2K compliant. must be able All to data store is sampled 12 weeks and of environmental stored at a rate data of two including samples a per time hour. stamp Fig. that 1 illustrates is Y2K compliant. one possible All data concept is sampled of the instrumentation and stored a rate of needed two samples for this per system. hour. Fig. 1 illustrates one possible concept of the instrumentation needed for this system. Fig. 1. Block diagram of Agriculture Field Instrument Fig. 1. Block diagram of Agriculture Field Instrument System Specifications Environmental: System Operating Specifications temperature: -10 to +45 degrees C Storage temperature: -40 to +85 degrees C Environmental: Humidity: 0-100% RH Operating temperature: -10 to +45 degrees C Power: Storage temperature: -40 to +85 degrees C Solar Humidity: powered from a 1 watt, 17.5 volt 0 - solar 100% panel. RH Battery storage with capacity for seven days of normal operation without recharging. Power: Instrumentation: Solar powered from a 1 watt, 17.5 volt solar panel. Soil moisture: Battery storage with capacity for seven days of normal operation 1 to 4 without time domain recharging. reflectometry (TDR) soil moisture probes model number CS615. Frequency range: 400hz to 900hz corresponds to 45% to 5 % volumetric water content

Soil moisture probe impedance: 10K minimum Soil moisture probe power: 12VDC @ 75ma minimum Ambient temperature: -20 to +40 degrees C ± 1 degree C. Ground temperature: 0 to +40 degrees C ± 1 degree C. Relative Humidity: 10% - 90% rh ± 5% Rain gauge: Tipping bucket input for dry relay contact with 100ma max contact rating. Communications: Radiometrix RPC UHF radio link Protocol TBD - proprietary Daughter board component on instrument PCB IRDa serial interface @ 9600 BAUD Protocol TBD WIN95/98 compatible User interface: Manual Control Menu select control, no numeric input Push button control mounted directly on PCB Operation TBD Computer control Same level of control as manual controls Ability to acquire logged data Ability to set system operational parameters LCD display Daughter board component on instrument PCB Menu displays TBD Data acquisition: All measured variables stored at 15-minute intervals 90 day data storage capacity Zero power NV memory Measurements time stamp for month-day-year-hour-minute Real time clock with Y2K compliance Expansion: Four 0-10 volt analog input ports with input impedance 10K ohm or greater. Packaging (printed circuit board): Dimensions: 6x4x3 in. (excluding battery and solar panel) Locking keyed connectors LCD and RPC plug directly onto PCB