SC8108-A. NetWork Cable Tester. User Operation Manual. Taking Its Source At Sanling Science & Technology Good helper to network



Similar documents
Multipurpose LCD Display Cable Test & Inspection Instrument

Multi Media Cable Tester TM-901N/TM-902/TM-903

INSTRUCTION MANUAL. NC-500 NETcat Pro Wiring Tester

Chapter 4 Connecting to the Internet through an ISP

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

MicroScanner 2. Users Manual. Cable Verifier

SignalTEK II. Save money by using a single multifunction device in place of separate copper, fiber and Power over Ethernet (PoE) testers

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Transmission of High-Speed Serial Signals Over Common Cable Media

Index. ROPIX P18 Hardware ROPIX P18 Software ROPIX P18

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

This paper will explain some of the more important factors on how UTP wires work; specifically it will cover the following:

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

CCNA Discovery Chapter Four

LDG DTS-4/4R Desktop Coaxial Switch / Remote

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

CAT5 KVM Extender User Manual

Advanced Systems Tester 900AST

5 in 1 Cable Tester RTK-T05 User Manual

CableIQTM. Users Manual. Qualification Tester

CableIQTM. Users Manual. Qualification Tester

Model CFA-24 Transparent Cable Farm Automation Switch

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

MicroScanner 2. Cable Verifier. Getting Started Guide

Communication Setup Application Note

Balun Bulletin- CCTV Systems- Termination

Network Design. Yiannos Mylonas

Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer

Cisco T1 Layer 1 Troubleshooting

NC-12 Modbus Application

Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems)

Terminating 25-Pair Cable and 4-Pair Cross Connects

Ⅱ Function Characteristics

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

SMART SENSOR COLLECTION

GSM Voice Auto Dialer & SMS Sender JC-999

GSM HOME SECURITY SYSTEM

HomePNA PCI Adapter. User s Manual

8-Port PoE Network Switch

Optional Lab: Install, Configure, and Partition a Second Hard Drive in Windows Vista

4-Channel Thermometer / Datalogger

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Technical Guide for Installation and Maintenance

User Manual of Grid Tie Inverter with Limiter

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

If you are unable to set up your Linksys Router by using one of the above options, use the steps below to manually configure your router.

User Manual Color video door phone

Light Meter (Foot Candles)

DISSOLVED OXYGEN METER Model : DO-5509

User Manual. Humidity-Temperature Chart Recorder. Model RH520

SVPRIBOR ALFA DSL. Users Manual

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

DPH-50U VoIP USB Phone Adapter Quick User Guide

Perle 10/100 Ethernet Media Converters

MANUAL FOR RX700 LR and NR

Arista 40G Cabling and Transceivers: Q&A

12 Volt 30 Amp Digital Solar Charge Controller

Ethernet Adapter Owner's Manual

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

CONSOLE REMOTE I /O AC 9V

User Manual GSM Alarm System. All rights reserved by Delta Security Co., Ltd

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

T3 Mux M13 Multiplexer

MCT-7 Multiple Cable Test System

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Ground Resistance Clamp On Tester

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

Infrared Digital Scouting Camera. User s Manual Pocket Camera

8 Channel Status Input Panel model SIP-8

Network & Internet Installation & Information Guide Fall 2004 Edition. Campus Ethernet For PCs using Windows 2000 & XP

Cisco Unified IP Conference Phone 8831 Installation

Setting Up the ZigBee Ethernet Gateway

10/100/1000 Base-T to Gigabit Fiber Media Converter

FlexPoint T1/E1 Copper to Fiber Line Driver

Jabra MOTION OFFICE. User Manual. jabra.com/motionoffice

GSM Alarm System User Manual

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Contents Contents Contents Overview Charging your headset Wearing the headset Powering on the headset Connecting your headset for dictation

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

2100 Series VoIP Phone

DC-8706K Auto Dial Alarm System

Notice. Reverse engineering and disassembly are prohibited.

Model: Manual DC: WIRELESS COLOR FORECAST STATION

RACEAIR REMOTE PAGER SYSTEM

DSB-100 Portable Premium Bluetooth Speaker Owner s Manual

SolarEdge. RS485 Expansion Kit Installation Guide. Version 1.0

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

USB to RS-422/485 Serial Adapter (ID-SC0911-S1/SC0A11-S1) User s Manual

PCI/PXI ETHERNET ADAPTERS

User's Manual. Model Laser Photo / Contact Tachometer. Introduction

GSM Door Phone System

Transcription:

SC8108-A NetWork Cable Tester User Operation Manual Taking Its Source At Sanling Science & Technology Good helper to network

1. The tester uses 6V DC as the power supply only. 2. Never attempt to connect and start the tester with any power supply other than the tester itself. 3. For an economic use of battery, the tester will shut off automatically if it does not work for 30 minutes in succession.

CONTENTS PREFACE ----------------------------------------------- 2 FUNCTION & FEATURES --------------------------- 3 TECHNICAL SPECIFICATION ----------------------- 4 INTERFACE & KEY DESCRIPTION ----------------- 5 OPERATION PROCEDURES ------------------------ 6 WIRING DIAGRAM (WIREMAP) TEST ------------------ 7 PAIR & LENGTH TEST ------------------------------------ 10 COAXIAL CABLE & TELEPHONE LINE TEST --------- 12 LENGTH UNIT SETUP ------------------------------------ 13 DYNAMIC CALIBRATION-------------------------------- 14

Preface NetWork Cable Tester is a powerful special tool to prevent and solve cable installation problem. NetWork Cable Tester is the best choice to verify any speech and data cable installation procedure. The tester is capable to have a number of tests such as cable connection sequence, length, user jumper and cable connection continuity and determine any open circuit, short circuit, jumper or cross-talk interference. It is a useful tool to reduce cable installation cost and save cable installation time. 02

Function & Features =One person enough to complete cable continuity check. =Check wiring error in 5E, 6E, coaxial cable and telephone line =such as open circuit, short circuit, jumper wire, reverse connection or cross-talk interference. =Locate the wiring or connection error. =Measure cable length and determine the distance of open circuit and short circuit. =Dynamically calibrate cable length and make length measurement as accurate as 97%. =Simple and easy use. Big screen to display test result clear. =Portable unit with long battery life (wait-case 50 hours). =Automatically time-delay shut off. =Measure length and pair with or without far-end recognizer. =Locate cable and there are 8 far-end passive test jacks (ID No. ID1-ID 8). =Far-end recognizer with prompting voice. =Self-checking function and automatically compensate any change in battery capacity or ambient temperature. =Single board computer software watchdog design and reliable operation. 03

Technical Specification (1). Overall Dimension 180 x 80 x 40 mm (2). Power Supply 4 x 1.5V Size AA batteries with power consumption 16 ma (3). Display Special 4 x 16 character big screen LCD lattice (valid visual field 61.6 x 25.2 mm) (4). Type of Test Cable STP/UTP twin twisted cable, coaxial cable, telephone line (5). Working Ambient Temperature -10= +60 (6). Tester Port Tester RJ45 master port (M), tester LOOPBACK RJ45 port (L), far-end recognizer RJ45 port (R). The extra BNC and RJ11 converters are used to measure and check the continuity of coaxial cable and telephone line. (7). Length Measurement of Twin Twisted Cable Scope: 1 350 M ( 3 1,200 ft) Calibration accuracy: 3% (+/- 0.5M or +/- 1.5 ft) (calibrating cable > 5 M) Shipment accuracy: 5% (+/- 0.5 M or +/- 1.5 ft). (AMP, AT&T Class 5 cable) Display: M or ft. (8). Length Calibration: User can set calibration factor by himself with a given length cable. The length of calibrating cable is more than 5 M. (9). Wire Sequence and Locating Cable Error: Check errors such as open circuit, short circuit, reverse connection, crossover or cross-talk interference. (10). Locating Cable 8 far-end passive test jacks (ID 1 ID 8). (11). Automatic Time-delay Shut Off Time: The tester does not operate for 30 minutes. 04

Interface and Key Description Power Supply The tester uses 4 x 1.5V Size AA alkaline batteries with power consumption 16 ma. The batteries should be taken out if the tester does not use for a long time to prevent the battery rack from leaking electrolyte corrosion. Tester Panel and Port SC8108-A LOOPBACK port MAIN port LCD display screen power switch function key confirmation/return key function key 05

Operation Procedures Start and display: Carry out self-checking at the same time (The dotted line dynamically displays the course of self-checking from left to right): 5 seconds or push any arbitrary key to display main menu. Main menu display: There are four functions to be chosen on main menu. 1. WireMap --- Wiring diagram measurement to check end-to-end continuity of cables M, L, R and locate error. 2. Pair & Length --- Pair and measure length to verify cable length, open circuit distance, pairing and cross-talk interference. 3. Coax/Tel --- Coaxial cable and telephone line measurement to check continuity and indicate open circuit and short circuit. 4. SETUP --- Calibrate and set up the tester (Refer to description hereinafter). With main menu display, push ===== key to move cursor J[indicator up and down to desired item and then push PAIR&L key to enter related test function accordingly. 06

Wiring diagram (WIREMAP) test function: After entering the wiring diagram (WIREMAP) test function, the tester shall carry out wiring diagram (WIREMAP) test and displays as follows while checking is being undertaken: Test Result 1: Short circuit (SHORT) It displays as follows if there is any short circuit in cable or terminal: (e.g. 12 short circuit in the sample) At the moment, push ======key to restart testing or push PAIR&L key to return main menu. Always correct short circuit error first and then start further measurement. Test Result 2: Neither far-end matcher (ID) is found nor cable inserts local port (L) The tester will automatically detect far-end matcher (ID) or local port (L) cable and it will display as follows if the far-end of cable to be checked does not insert into the far-end matcher (ID) or if the cable does not insert into the local port (L) in local test: At the moment, push == key to restart testing or push PAIR&L key to return main menu. 07

Test Result 3: Normal wiring diagram (WIREMAP) display The tester will automatically detect far-end matcher (ID) or local port (L) cable and it will display wiring diagram (WIREMAP) as follows if it is found the far-end matcher (ID) or the local port (L) on the far-end of cable to be checked: "R:" line shows RJ45 jack pin number of far-end port and "ID1"is the farend matcher number. " " line shows the connecting line between far-end port and master port. "M:" line shows the RJ45 jack pin number of master port. At the moment, push ==== key to restart testing or push PAIR&L key to return main menu. Test Result 4: Wiring diagram (WIREMAP) display when there is an open circuit at the far-end of cable. "R:" line "3" and "6" pins location display "x", it indicates an open circuit in far-end plug "3" and "6" pins and the open circuit is located nearby the far-end plug.(the open circuit should be located within 10% cable length if it is measured from the far-end plug) Note: If you use far-end matcher (ID) to measure wiring diagram (WIREMAP), because the test is made via the paired two cable cores, the open circuit at the far-end always displays in pair as shown above where there is one open circuit or all are open circuits in the far-end "3" and "6"pins. For identification, it is simple to move the tester to the far-end to have the measurement. 08

Test Result 5: Wiring diagram (WIREMAP) display when there is an open circuit at the near-end of cable. It will display wiring diagram (WIREMAP) as follows if there is an open circuit at the near-end plug of the cable: "M:" line "3" pin location displays "x", it indicates an open circuit at nearend plug "3" pin and the open circuit is located nearby the near-end plug. (The open circuit should be located within 10% cable length if it is measured from the near-end plug) Test Result 6: Wiring diagram (WIREMAP) display when there is an open circuit in the middle of the cable. It will display wiring diagram (WIREMAP) as follows if there is an open circuit in the middle of the cable: " " line "3" pin location displays "x", it indicates an open circuit in the middle of "3" pin cable. (The open circuit should be located within 10% - 90% cable length if it is measured from the near-end plug.) For further locating open circuit, the pair and length function (PAIR & LENGTH) of the tester could used as detailed hereinafter. 09

Pair and length measurement (PAIR & LENGTH) function: No matter whether there is a far-end recognizer (ID) at the far-end of the cable, the tester is capable to have pair and length (PAIR & LENGTH) measurement. Therefore, the far-end recognizer (ID) can keep connected in the course of wiring diagram (WIREMAP) and pair and length (PAIR & LENGTH) measurement to avoid repeated insertion and pulling out. After entering into pair and length (PAIR & LENGTH) measurement function, the tester shall have pair and length (PAIR & LENGTH) test and it will display as follows to indicate the measurement is being undertaken: Note: In view of different technical parameters in various brand cables, the user should apply the tester dynamic calibration function before length measurement (Refer to the details herein). Test Result 1: Short circuit (SHORT) It will display as follows if there is any short circuit in cable or terminal: ( 12 short circuit in the sample) (The tester is incapable to know the exact location of short circuit.) At the moment, push =====key to restart test or push PAIR&L key to return the main menu. Always correct short circuit error first and then start further measurement. 10

Test Result 2: Normal pair and length (PAIR & LENGTH) display It will display as follows if pair and length (PAIR & LENGTH) measurement is in normal condition: In which, the figure (e.g. 12) after the pair is the pair line number and it is the length after the line number. At the moment, push ==== key to restart test or push PAIR&L key to return the main menu. Test Result 3: Abnormal pair and length (PAIR & LENGTH) display It will display the paired lines first if there is unpaired lines in the pair and length (PAIR & LENGTH) measurement: In which, the last line (78 ) indicates there is no pair is found in lines 7 and 8, at the moment, it will display the length of unpaired line number (as shown below): if you push the key: ( Or push PAIR&L key to return the main menu) It will display "X" to indicate an open circuit if the length is less than 90% of other line pair length and the open circuit is located at around 89.7 M from the tester. (The open circuit line number could be rechecked by WIREMAP function.) At the moment, push = key to go back previous picture and éìëü âéó=íç=ëüçï=ñìêíüéê=ìåé~áêéç=äáåé=åìãäéê=äéåöíük=elê=éìëü=m^foci âéó=íç=êéíìêå=íüé=ã~áå=ãéåìf 11

Coaxial cable and telephone line measurement function: After entering into coaxial cable and telephone line measurement (Coax/ Tel) function, the tester shall have test and show the test result as follows: It shall displayopen if there is any open circuit or the coaxial cable and telephone line is not connected. It shall display SHORT= if there is any short circuit. At the moment, push ===key to repeat the measurement or push PAIR&L key to return the main menu. The far-end recognizer will have beep prompt sound if the connection is in normal condition. Note: For coaxial cable measurement, it needs accessories: two (2) BNC matchers. One is used to connect M port RJ45 and the cable to be checked and the another is used to connect the far-end matcher R port and the cable to be checked. For telephone line measurement, it needs accessories: two (2) RJ11 matchers. One is used to connect M port RJ45 and the cable to be checked and the another is used to connect the far-end matcher R port and the cable to be checked. 12

Calibration and setup (SETUP) function: After entering into calibration and setup (SETUP) function, the tester shall display as follows: Push === key to move cursor=j[indicator up and down to the desired item and then push PAIR&L key to enter related setup function accordingly. UNIT: It is used to set up length unit and shifts between meter (Meter) and feet (FT). CALIBRATION is calibration function. (Detailed as related chapters hereinafter) QUIT is used to return the main menu. 13

Dynamic calibration (CALIBRATION) function: (Another way to quickly enter into dynamic calibration: hold PAIR&L key while start the tester) For an accurate measurement of cable length, the calibration operation should be done as follows. After entering into dynamic calibration function, the tester shall display as follows: Push key (No) to exit calibration function. Insert same type cable of given length into M port, do not need insert far-end recognizer, push = key (Yes) to undertake measurement and display the measured length (as shown below): At the moment, hold and key (-/+) to display the length to be adjusted to actual given length and then push PAIR&L key to reserve calibration factor and exit calibration function. 14

It will display as follows if the cable length being measured is too short ( < 5M) to remind the user to change a longer cable for calibration: At the moment, push key (No) to exit calibration function. Push key (Yes) to repeat the measurement. It will display as follows if there is an open circuit in the measuring cable length to remind the user to change a normal cable for calibration: At the moment, push (Yes) to repeat the measurement. key (No) to exit calibration function. Push key Note: If the tester is restarted after it shuts off, the tester will recover the standard calibration factor of Class UTP5 cable as setup before shipment. 15

SC8108-A NetWork Cable Tester