Unmatched Metal Hardness Testing



Similar documents
Portable Hardness Tester

Portable Hardness Testing Leeb Rockwell UCI

How To Test A Rockwell Type Hardness Tester

VERZUS 750CCD Universal Hardness Tester

LEEB HARDNESS TESTER TH130/132/134

Mobile Hardness Testing

HR-200/300/400/500 Series

Using Equotip Hardness Test Blocks Abstract 1. Introduction 2. Verification of Leeb hardness testers according to standards

MENG 302L Lab 1: Hardness Testing

VICKERS HARDNESS TESTER. HBS HBW Kc

Description of mechanical properties

Multifunction HVAC and IAQ Meter

MT90 Series MicroHardness Traverse Testing System

Highly efficient flue gas analyzer

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

SERIE NEMESIS 9000 TM

DMS 680. Universal length measuring system gauge inspection for»iso 9000«requirements

MEASURING AND LEVELING TOOLS

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

86 C Freezer Accessories. More Choices. Choose from a Wide Selection of Racks, Monitoring Systems and Other New Brunswick Freezer Accessories

Wind Direction Smart Sensor (S-WDA-M003)

Hand-held thermometer Model CTH7000

CYMAQ Marking System AS200 + DS7050 N-14

Measuring electric and magnetic fields

Hardness Testing at Elevated Temperatures. SJ Shaffer, Ph.D. Bruker-TMT

VeMet, Utrecht, NL «Solution in Wear Protection» Dipl.-Ing. Wolfgang Leichnitz. Quit

Handheld portable appliance testers

Current Monitoring Kit QUICK START GUIDE

COMBIMASS. Technical Data COMBIMASS eco-bio +

Comparison of results and test methods using the Micro IRHD and the Micro Shore rubber hardness measurement instruments

Current Monitoring Kit

-86 C Freezer Accessories. New Brunswick Freezer Accessories. A wide selection of racks, monitoring systems and more!

Precision Lightmeters Made in Germany

Items Supplied. Frequency. Designation Description / Delivery Unit Order Number

Guideline Laser Series

BB-18 Black Body High Vacuum System Technical Description

Nardalert S3 Non-Ionizing Radiation Monitor

TR Series Surface Roughness Tester for workshop and laboratory

SCS Directory Accreditation number: SCS 0115

How To Use A Ds340 (Dsp)

Product Specification instalert Rapid Messenger Variable Message Sign

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

ME 354, MECHANICS OF MATERIALS LABORATORY

Quality Assured. NEWAGE MT90 Series Microhardness Traverse Testing System. Newage Hardness Testing

PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES

Understanding the IRHD and Shore Methods used in Rubber Hardness Testing

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

User's Guide. Integrating Sound Level Datalogger. Model Introduction

PORTABLE FLOW METER KITS TDS-100H

Pipe Cutting and Beveling Clamshells

DRO Function guide: Zero setting 1/2 calculation mm/inch conversion INC/ABS conversion

MANUAL TR-110 TR-110

Lithium Ion Battery Specifications

ULTRASONIC THICKNESS GAUGE TT100/110/120/130

Penetration Testing for Material Hardness

Nikon s DigiMicro Position Encoders Nanometer Resolution with Sub-Micron Accuracy

HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP ver.1.0

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Test equipment for temperature and its reduction

Understanding the Wire EDM Process

USB-500 Series Low-Cost Data Loggers and Accessories

SJ-201P/M PORTABLE SURFACE ROUGHNESS TESTER

Digital Dental X-ray. Midmark Animal Health Products

Torque Transducers MEASURING ELECTRONIC

USB-500/600 Series Low-Cost Data Loggers and Accessories

IR-PRO IR-PRO. Operation Guide. Professional Infrared Code Capture System

Computerized Electronic Univesal Testing Machine WDW-20Y

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Physical Specifications (Custom design available.)

MTR X-SERIES bench hardness tester

Key Features. Product Overview. Threaded Joint Rate Simulator

The measuring of the hardness

A-307. Mobile Data Terminal. Android OS Platform Datasheet

Multi-Function Ground

Pipeline External Corrosion Analysis Using a 3D Laser Scanner

SHAFT ALIGNMENT. Quick, simple and effective! PC SOFTWARE INCLUDED PRINTER CONNECTION EXPANDABLE MEASUREMENT VALUE FILTER COMPENSATION THERMAL GROWTH

PreciTrack3D GmbH. PRECI 3D TRACK PRECI 3D GUN PRECI 3D SCAN PRECI 3D ROBOGUN PRECI 3D CONFOCAL PRECI 3D REF Tube Inspection & Measurements PRODUCTS

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Real-Time Car GPS Tracker (Portable, Weatherproof, Magnet, More)

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Adapter Catalog MOBILE METAL ANALYZER. SPECTRO isort and SPECTROTEST

iva Cable & Antenna Analyzer

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

PRACTICAL HARDNESS TESTING MADE SIMPLE. Table of Contents 1. GENERAL 1 2. INTRODUCTION 3 3. BRINELL HARDNESS TESTING 9 4. VICKERS HARDNESS TESTING 14

Typical Aluminum GFM Mass Flow Meter

Tubing Data. Contents. Tubing Selection. Tubing Handling. Tubing Material. Tubing Outside Diameter Hardness. Tubing Wall Thickness

Digital inductive conductivity transmitter

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Thickness Gauges. convex R 15 or R 40, flat 10 mm Ø, spherical

EMR-300 Broadband RF Survey Meter

Product Information Sheet UH28CS-12kV Hi Pot Tester

R E P O R T N U M B E R QI

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

Company and Product Presentation

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

Transcription:

Unmatched Metal Hardness Testing The Equostat 3 hardness tester can be connected both to the portable Equotip 3 platform and directly to a PC, with graphic user guidance Hardness Measurements made easy Stationary hardness testers can only accomodate test pieces of limited size. Moreover, transportation of the test pieces is often impractical. The Equostat 3 works well in outdoor, factory and lab environments, and has only very few requirements on test piece geometries. The Equostat 3 probe can be connected directly to a laptop or PC, on which live user guidance dialogs as well as the hardness readings are displayed. Alternatively, the probe plugs into the Equotip 3 indicating device to combine the Rockwell principle of Equostat 3 with the Leeb rebound principle of Equotip to become the most versatile hardness tester. Stable Measurements according to DIN 50157 and ASTM B724 In contrast to other portable hardness test methods, such as UCI, Equostat 3 generates (via penetration depth measurements) true hardness readings rather than a comparative value. Compared to stationary testers, Equostat 3 uses a sharper indenter and smaller loads. The test method is standardized both according to DIN 50157 (metals) and ASTM B724 (aluminum). The conversions from Rockwell hardness to many other scales follow the ISO 18265 and the ASTM E140 tables. The Equostat 3 displays the signal curve as well as operating instructions in real time. This enables users to achieve the most repeatable measurements of any commercially available hardness tester. Benefits to the Customer Standards conformance: True hardness reading rather than comparative value; conforms to DIN 50157 and ASTM B724 with ISO 18265 or ASTM E140 conversions. Uniqueness: The first hardness tester that connects directly to a PC and to the portable Equotip 3 testing platform. User guidance: The user is instructed precisely when to apply and release the test loads; the displayed signal curve enables the user to judge the quality of the measurement. Repeatability: Unmatched by the competition. Robustness: The new Equostat 3 indenter is extremely durable; the probe features a protective rubber sleeve. Versatility: Measuring clamp, magnetic feet, and special feet adapt to most sample shapes. Software: The included PC software package Equolink 3 addresses professional data management needs.

The Portable Rockwell Principle The hardness testing principle in Equostat 3 follows the Rockwell stationary test. During measurements with the Equostat 3 probe, a diamond indenter is forced into the test piece to be measured and then released back out of the material. The indentation depth of the diamond is continuously measured while the load is applied and released. From the indentation depths d 1 and d 2 recorded at two defined loads, the difference is calculated: Δ = d 2 d 1. The difference Δ is a direct measure of the hardness of the material, and is independent of the test direction. There are three main differences to traditional stationary Rockwell tests: 1. The test loads are lower. 2. The Equostat 3 indenter is sharper. 3. The dwell times during a test are shorter. Functionality that fits your Needs Measurement on Basis of DIN 50157 Both depth measurements d 1 and d 2 are taken at preload, first during application (d 1 ) and then after release of the total load (d 2 ). The difference between the depths d 1 and d 2 originates from the deformation response of the material to penetration. Measurement on Basis of ASTM B724 The depth measurements are taken at preload (d 1 ) and at the total load (d 2 ), respectively. This method is applicable to aluminum samples only. User guidance dialogs The measurement signal is displayed in real-time on a PC screen or the Equotip 3 indicating device. This allows the user to judge the quality of the ongoing measurement through evaluation of the signal curve. Measurements are Non-Destructive Due to the low test loads, Equostat 3 only penetrates a few micrometers of the test piece, making the test particularly suitable for: Scratch-sensitive and polished surfaces Thin parts, profiles and pipes with a wall thickness 2 mm Hardness profiles in heat-affected zone of welds Equostat 3 probe connected to PC

Key Advantages to other Hardness Testing Methods The Equostat 3 has a great number of advantages compared to other hardness testing techniques: Compared to: Equostat 3 s key advantages are as follows: stationary Rockwell Equostat 3 has lower loads permitting to test surface layers stationary Brinell Equostat 3 indentations are much smaller Poldi hammer Equostat 3 is a direct measurement, as opposed to a comparative test stationary Vickers No optical readout necessary in Equostat 3 micro Vickers Equostat 3 can be used also in dirty environments Leeb rebound Equostat 3 has no requirements on the sample weight Shore scleroscope Equostat 3 measurements are independent of the test direction UCI Equostat 3 achieves more repeatable testing with less user dependence, and is a direct measurement, as opposed to a comparative test TIV Equostat 3 has very rugged diamond indenters electrical penetration depth Also non-conductive samples can be tested with Equostat 3 Test Piece Requirements Probe setup Minimum test piece thickness Maximum test piece thickness Test piece surface condition Surface curvature Maximum test piece hardness Minimum spacing 50 N probe with clamp 40 mm 50 N probe with round standard foot (ø = 42 mm) 50 N probe with tripod 50 N probe with long foot 1 mm at ~20 HB 130 μm at ~70 HRC N/A recommended mean surface roughness R a < 2 μm to minimize data scatter foot to be used for plane surfaces very small curvatures acceptable very small curvatures acceptable 70 HRC recommended < 60 HRC three times the diameter of a test indentation 50 N probe with special feet 18-70 mm radius of curvature or 70 mm - 70 HRC The Right Measuring Setup for the Application To access various test locations and to accommodate user preferences, the Equostat 3 offers a range of adaptors. The measuring clamp can easily be adjusted to the sample thickness. Additional adaptors for bolts, wires and thin tubes further allow measurements on different sample geometries. Equostat 3 can be automated with third-party remote one-axis test setups and the Equotip 3 Automation Package. Adaptors for different applications Measuring clamp Magnetic foot

Equostat 3 Freehand probe feet: Standard round foot Ideal for flat parts, and test locations more than 10 mm from an edge. Tripod foot Designed for tests that require accurate positioning (welds, heat-affected zones) Long probe foot Optimal solution for restricted and narrow geometries, where high aiming accuracy is required (welds, heataffected zones) Special feet RZ 18-70 and RZ 70- Designed for curved test pieces such as cylindrical parts, tubes, pipes Part no. 354 01 127 (included) Part no. 354 01 130 Part no. 354 01 141 Part no. 354 01 250 354 01 253 Equostat 3 Clamp adapters: The Equostat 3 measuring clamp (part no. 354 01 200) is designed for small parts, pipes, and difficult geometries. Standard flat support Z1 V-notch support Z2 Pipe support Z4+28 Pipe support Z4 (included) Part no. 354 01 243 Part no. 354 01 229 Part no. 354 01 228

Measuring Thin Samples and Layers DIN 50157, like other hardness testing standards, specifies the minimum thickness of the sample or layer under test to be at least 10 times the penetration depth of the indenter during the measurement. Thanks to its unique design, the penetration depth of Equostat 3 is very shallow, resulting in the unrivalled capability to measure thin samples and layers. The below chart provides a guideline regarding penetration depth and minimum sample thickness. Technical Information Equostat 3 Equostat 3 Probe Measuring range 19-70 HRC; 19-70 HMMRC; 67-638 HB; 35-950 HV; 60-86 HRA; 29-107 HRB; 225-2250 MPa; 69-94 HR15N; 88-96 HR15T Resolution 0.1 μm; 0.1 HRA; 0.1 HRB; 0.1 HRC; 0.1 HRE; 0.1 HRH; 0.1 HR15N; 0.1 HR15T; 1 HB; 1 HV; 0.1 HS; 1 MPa Measuring accuracy ~ ± 1.5 HRC according to DIN 50157 Maximum test hardness 70 HRC Test direction any direction (no correction required) Test loads 10 N / 50 N Diamond indenter angle 100.0 ± 0.5 Equotip 3 Indicating Device Dimensions 170 x 200 x 45 mm (6.7 x 7.9 x 1.8 inches) Weight 780 g (27.5 oz) plus battery pack 120 g (4.2 oz) Display 4.7 QVGA LCD with adjustable contrast and backlight Internal data storage 100'000-1 000 000 values (depending on data type) Interface Ethernet, USB 1.1, RS 232 Battery type rechargeable Li ion or 3 standard size C cells Battery max. charge voltage 4.2 V Battery operation period typically 10 hours Operating temperature 0 to + 50 C (32 to 122 F) Humidity non-condensing, 90% max

Ordering Information Part No. Description Picture 354 01 000 Equostat 3 Hardness Tester - Clamp Unit Consisting of: Indicating device with stand, AC adapter, Equostat 3 probe 50 N (with 2.0m 4-pole/ USB cable, indenter, round standard foot, protective rubber sleeve), measuring clamp, Equostat 3 test block (~62 HRC), USB cable, Equotip CD with Equolink 3 software and product documentation, operating instructions, product certificates, carrying case 354 01 001 Equostat 3 Hardness Tester - Freehand Measuring Unit Consisting of: Indicating device with stand, AC adapter, Equostat 3 probe 50 N (with 2.0m 4-pole/ USB cable, indenter, round standard foot, protective rubber sleeve), Equostat 3 test block (~62 HRC), USB cable, Equotip CD with Equolink 3 software and product documentation, operating instructions, product certificates, carrying case 354 01 002 Equostat 3 Hardness Tester - PC Unit Consisting of: Equostat 3 probe 50 N (with 2.0m 4-pole/USB cable, indenter, round standard foot, protective rubber sleeve), Equostat 3 test block (~62 HRC), Equotip CD with Equolink 3 software and product documentation, operating instructions, product certificates, carrying case 353 10 050 Equotip 3 Hardness Tester - Basic Unit Consisting of: Indicating device with stand, AC adapter, USB cable, Equotip CD with Equolink 3 software and product documentation, operating instructions, product certificates, carrying case 353 00 091 Equotip 3 Automation Package Consisting of: Activation code, 2.0m 4-pole cable with automation branch connector, Equotip CD with automation libraries, Equolink 3 software and product documentation, operating instructions Accessories Part No. 354 01 200 354 01 127 354 01 130 354 01 141 354 01 250 354 01 253 Description Equostat 3 measuring clamp Equostat 3 round standard foot Equostat 3 tripod Equostat 3 long probe foot Equostat 3 special foot RZ 18-70 Equostat 3 special foot RZ 70-354 01 137 Equostat 3 protective rubber sleeve Part No. 357 41 100 357 42 100 357 44 100 357 90 918 357 90 928 357 90 938 Description Equostat 3 test blocks Equostat 3 test block calibrated by Proceq (~20 HRC) Equostat 3 test block calibrated by Proceq (~45 HRC) Equostat 3 test block calibrated by Proceq (~62 HRC) Test block calibrations by accredited institute Additional calibration in HB (ISO 6506-3) Additional calibration in HV (ISO 6507-3) Additional calibration in HR (ISO 6508-3) Applicable Standards DIN 50157 (2007) ISO 18265 (2003) ASTM B724 ASTM E140 (2007) DGZfP Guideline MC 1 (2008) VDI / VDE Guideline 2616 Paper 1 (2010) Service and Warranty Information Proceq is committed to providing complete support for the Equostat 3 by means of our global service and support facilities. Furthermore, each instrument is backed by the standard Proceq warranty and extended warranty options. Subject to change without notice. All information contained in this documentation is presented in good faith and believed to be correct. Proceq SA makes no warranties and excludes all liability as to the completeness and/or accuracy of the information. For the use and application of any product manufactured and/or sold by Proceq SA explicit reference is made to the particular applicable operating instructions. Head Office Proceq SA Ringstrasse 2 CH-8603 Schwerzenbach Switzerland Phone: +41 (0)43 355 38 00 Fax: +41 (0)43 355 38 12 info@proceq.com www.proceq.com 810 354 01 E ver. 11 2011 Proceq SA, Switzerland. All rights reserved.