Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters



Similar documents
TANKLESS DURABILITY Tankless Product Guide

SOLI TANKLESS PRODUCT GUIDE

NAVIEN AMERICA INC FITCH AVENUE

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Commercial Gas Water Heaters

SOLID. STATE. StateWaterHeaters.com

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Commercial Gas Water Heaters

Commercial Gas Water Heaters

SPIDERfire: Delivers high efficiency and real savings for today s businesses

Tankless water heaters

On-Demand Water Heater Installation Manual and Owner s Guide

Cooling Capacity CFM in. w.c. (125 Pa)

Better Boilers.

Commercial Gas Water Heater

Cooling Capacity CFM in. w.c. (125 Pa)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

DRAFT HOOD OUTLET GS6-30-YORT NG Select - Tall - C3 Technology 28 FIRST HOUR RATING BTU INPUT PER HOUR

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Navien Condensing 98% Tankless Water Heaters. Tankless Water Heaters. Navien Condensing. The Ultimate in Energy Efficiency with Hi-Tech Comfort

Cooling Capacity CFM in. w.c. (125 Pa)

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR

THERM Tankless Water Heaters. Applications Manual

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

G9MXE. Product Specifications

F9MXE. Product Specifications

HEAVY DUTY STORAGE GAS

XV 95. Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace PUB. NO.

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

2010 Residential Water Heater Replacement Check List

RECON WATER HEATER INSTALLATION FORM

Cast-Iron Performance Meeting today s commercial demands with effi ciency, strength and intelligent controls.

CONDENSING TANKLESS WATER HEATERS

G234X-55 Conventional Gas Boiler

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

Commercial Gas Furnace Upflow

Versatility ::::::::::::::::::::::::::::::::::::::: the best. mod/con Performance. and UP TO.

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

T-K3 Instantaneous Water Heater Installation Manual and Owner s Guide

Applications manual. For tankless and point-of-use water heaters

Please keep this manual for f uture reference.

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

MAC-120HE-01 Air-Cooled Chiller

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

Applications manual. For tankless and point-of-use water heaters

TECHNICAL MANUAL GDS8 & GHS8

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

ECOCIAT. Domestic hot water heat recovery unit

Congratulations! You've just purchased a new Marey Power Gas tankless water heater and will soon begin to enjoy the benefits of going tankless.

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

Eternal Hybrid: Engineered For How You Live. Award Winning Technology. Now Available in Canada.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

SECTION HEAT PUMPS

Water Heaters. Condensing Storage. In my 30-plus years as a plumbing contractor,

On-Demand Water Heater Installation Manual and Owner s Guide

T-KJr. Instantaneous Water Heater Installation Manual and Owner s Guide

GTS Gas-to-Steam Humidification System

Arapahoe County Residential Water Heater Installation and Inspection Guide

Commercial Semi-Instantaneous Water Heaters

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

RESIDENTIAL PRODUCT CATALOG

Service Manual. Condensing Boiler. Getting Service


ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

REGULATORS 175/153 Series

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Tempra / DHC-E. Simply the Best The Finest Tankless Electric Water Heater Available! Featuring Advanced Microprocessor Control

On-Demand Water Heater Installation Manual and Owner s Guide

On-Demand Water Heater Installation Manual and Owner s Guide

910 / 910 ASME (T-M50/T-M50 ASME) On-Demand Water Heater Installation Manual and Owner s Guide

Local Dealer:

Vitodens 200, B2HA / B2HB - Product Introduction

n NOTICE n WARNING Read and review this entire manual with special emphasis on the Venting and Operation Sections prior to any installation work.

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

STATE-RES-GAS-State Residential Gas Water Heaters RW List Prices - Page T-1

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Installing, Operating & Maintaining EVO HIGH EFFICIENCY WATER HEATERS AND HEATING BOILERS

Cased/Uncased Coils For Gas And Oil Furnaces

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Electric & Gas Water Heaters

High efficiency, cast-iron gas boiler

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

ASME Packaged Indirect Fired Water Heater

ASX7-4-IOM-7 J

Commercial Boiler Systems and Controls

Models: NRC111-SV NRC111-DV* * FOR USE IN RESIDENTIAL, COMMERCIAL, OR MANUFACTURED HOME APPLICATIONS.

Technical Data Manual

Tankless Water Heating Solutions Residential and Commercial Applications

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Transcription:

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger is constructed of HRS35 Commercial-Grade Copper which is more resilient against erosion Secondary Heat Exchanger is made of Type 316L Stainless Steel to protect against corrosion CONTINUOUS MAXIMUM FLOW RATES UP TO 10.0 GPM ENERGY STAR QUALIFIED AVAILABLE IN NATURAL GAS OR PROPANE (LP) T-H3-DV & T-H3-OS CAN BE USED IN BOTH RESIDENTIAL AND COMMERCIAL APPLICATIONS ELECTRONIC IGNITION - NO PILOT LIGHT INDOOR MODEL - INCLUDES A BUILT- IN TEMPERATURE CONTROLLER AND ADVANCED DIAGNOSTICS TO SIMPLIFY TROUBLESHOOTING OUTDOOR MODEL - INCLUDES A WALL MOUNT TEMPERATURE REMOTE CONTROLLER AND ADVANCED DIAGNOSTICS TO SIMPLIFY TROUBLESHOOTING FACTORY-INSTALLED POWER CORD INCLUDED FOR INDOOR MODELS EASY-LINK UP TO 4 UNITS (T-H3 MODELS ONLY) With no additional parts or accessories needed MULTI-LINK UP TO 20 UNITS (T-H3 MODELS ONLY) COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse INTERNAL FREEZE PROTECTION SYSTEM POWER DIRECT VENT DESIGN Exhaust, 3" PVC Venting up to 70 Feet or 4" PVC Venting up to 100 Feet Provides flexible venting with PVC, CPVC, or ABS Pipe for Intake and Exhaust (solid core only). Canadian Installations Require ULCS636 Listed PVC or CPVC Pipe for Venting. Category IV Stainless Steel venting can also be used ACCESSORIES Pipe Cover Neutralizer Kit Isolation Valve Kits Concentric Termination WARRANTY 12-year limited warranty on heat exchanger in residential applications 5-year limited warranty on heat exchanger in commercial applications 5-year limited warranty on all parts T-H3 model only INDOOR MODELS T-H3J-DV, T-H3S-DV, T-H3-DV OUTDOOR MODELS T-H3J-OS, T-H3S-OS, T-H3-OS ANSI Z21.10.3 CSA 4.3 Page 1 of 6 www.takagi.com TRGSS01512

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters TANKLESS HIGH EFFICIENCY CONDENSING MODELS MODEL NUMBER FUEL TYPE GAS CONSUMPTION INPUT MIN. BTU/H MAX. BTU/H INLET GAS PRESSURE MIN. W.C. ENERGY FACTOR (EF) All dimensions are in inches. 15-150 psi Water Pressure. 40 psi or above is recommended for maximum flow. *Current numbers based on factory testing; 0.4 GPM required for continuous fire after initial ignition. Indoor models are certified from sea level to 10,100 ft. elevations. In accordance with ANSI Z21.10.3, CO emission does not exceed 400 PPM for normal input. The manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligation. MAX. W.C. MAX GPM* HOT/COLD GAS CONN. A HEIGHT DIMENSIONS IN INCHES INDOOR T-H3J-DV-N Natural 15,000 160,000 10.5 0.95 6.6 3/4 NPT 22-1/2 17-3/4 10-3/4 58 T-H3J-DV-P Propane 13,000 160,000 1 0.95 6.6 3/4 NPT 22-1/2 17-3/4 10-3/4 58 T-H3S-DV-N Natural 15,000 180,000 10.5 0.95 3/4" NPT 22-1/2 17-3/4 10-3/4 58 T-H3S-DV-P Propane 13,000 180,000 1 0.95 3/4" NPT 22-1/2 17-3/4 10-3/4 58 T-H3-DV-N Natural 15,000 199,000 10.5 0.95 10.0 3/4" NPT 22-1/2 17-3/4 10-3/4 59 T-H3-DV-P Propane 13,000 199,000 1 0.95 10.0 3/4" NPT 22-1/2 17-3/4 10-3/4 59 OUTDOOR T-H3J-OS-N Natural 15,000 160,000 10.5 0.95 6.6 3/4 NPT 22-1/2 17-3/4 10-3/4 58 T-H3J-OS-P Propane 13,000 160,000 1 0.95 6.6 3/4 NPT 22-1/2 17-3/4 10-3/4 58 T-H3S-OS-N Natural 15,000 180,000 10.5 0.95 3/4" NPT 22-1/2 17-3/4 10-3/4 58 T-H3S-OS-P Propane 13,000 180,000 1 0.95 3/4" NPT 22-1/2 17-3/4 10-3/4 58 T-H3-OS-N Natural 15,000 199,000 10.5 0.95 10.0 3/4" NPT 22-1/2 17-3/4 10-3/4 59 T-H3-OS-P Propane 13,000 199,000 1 0.95 10.0 3/4" NPT 22-1/2 17-3/4 10-3/4 59 B WIDTH C DEPTH UNIT WEIGHT (LBS) Page 2 of 6 www.takagi.com TRGSS01512

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters INDOOR MODEL 4" (102 mm) Female 17-3/4" (450 mm) 7" (180 mm) 4" (101 mm) 4" (102 mm) Female 11-1/4" (285 mm) 5-3/4" (147 mm) 24-7/8" (631 mm) 23-5/8" (600 mm) 6-1/4" (159mm) 22-1/2" (570 mm) Exhaust 2-5/8" (65 mm) Intake 2-5/8" (68 mm) 10-3/4" (272mm) HOT 4-3/4" (120 mm) Drain port 6-3/4" (170 mm) COLD 5/8" (17 mm) 120 VAC 3" (77 mm) GAS 5-3/4" (147 mm) 7-1/2" (189 mm) 1/2 (13 mm) GAS 5-1/8" (131 mm) HOT 5-1/2" (140 mm) Drain port 6" (152 mm) COLD 6-3/4" (172 mm) 120 VAC 6-7/8" (174 mm) HOT 4-3/4" (120 mm) 7-1/2" (189 mm) GAS 5-7/8" (147 mm) 120 VAC 3" (77 mm) HOT 5-1/2" (140 mm) 120 VAC 6-7/8" (174 mm) GAS 5-1/8" (131 mm) COLD 6-3/4" (172 mm) 5-3/4" (147 mm) 17-5/8" (448 mm) COLD 5/8" (17 mm) 6-1/4" (159 mm) Page 3 of 6 www.takagi.com TRGSS01512

Residential/Commercial Gas Gas Condensing High High Efficiency Tankless Water Water Heaters OUTDOOR MODEL 17-3/4" 17-3/4" (450 (450 mm) mm) 7" (180 7" (180 mm) mm) 4-1/2" 4-1/2" (114 (114 mm) mm) 11-1/4" 11-1/4" (285 (285 mm) mm) 11" 11" (281 (281 mm) mm) 10-3/4" 10-3/4" (272 (272 mm) mm) HOT HOT 4-3/4" 4-3/4" (120 (120 mm) mm) 120 120 VAC VAC 6-1/4" 6-1/4" (159 (159 mm) mm) Drain Drain port port 6-3/4" 6-3/4" (170 (170 mm) mm) COLD COLD 5/8" 5/8" (17 (17 mm) mm) GAS GAS 5-3/4" 5-3/4" (147 (147 mm) mm) Condensate drain drain port port 7-1/2" 7-1/2" (189 (189 mm) mm) HOT HOT 4-3/4" 4-3/4" (120 (120 mm) mm) Condensate drain drain port port 7-1/2" 7-1/2" (189 (189 mm) mm) 17-5/8" 17-5/8" (448 (448 mm) mm) HOT 5-1/2" (140 mm) 120 HOT VAC 5-1/2" 3" (77 (140 mm) mm) 120 VAC 3" (77 mm) GAS 5-1/8" (131 mm) GAS COLD 5-1/8" 6-3/4" (131 (172 mm) mm) Condensate COLD 6-3/4" drain (172 mm) port 24-7/8" (631 mm) 24-7/8" (631 mm) 23-5/8" (600 mm) 23-5/8" (600 mm) 3-5/8" (92 mm) 3-5/8" (92 1-1/2" mm) (37 mm) 1-1/2" (37 mm) 22-1/2" (570 mm) 22-1/2" (570 mm) 1/2" 1/2" (13 (13 mm) mm) 120 120 VAC VAC 3" (77 3" (77 mm) mm) GAS GAS (131 (131 mm) mm) HOT HOT (140 (140 mm) mm) Drain Drain port port 6" (152 6" (152 mm) mm) COLD COLD 6-3/4" 6-3/4" (172 (172 mm) mm) Condensate drain drain port port 7-7/8" 7-7/8" (199 (199 mm) mm) 120 120 VAC VAC 6-1/4" 6-1/4" (159 (159 mm) mm) COLD COLD 5/8" 5/8" (17 (17 mm) mm) Page Page 4 of46 of 6 www.takagi.com TRGSS01512

Residential/Commercial Gas Gas Condensing High High Efficiency Tankless Water Water Heaters FLOW RATEvsvs TEMPERATURE RISE T-H3J-DV/OS Flow Flow Rate Rate vs. vs. Temperature Rise Rise 11.0 11.0 10.0 10.0 9.0 9.0 2.0 2.0 1.0 1.0 0.0 0.0 0 0 20 20 40 40 60 60 80 80 100 100 Temperature Rise Rise ( F) ( F) T-H3S-DV/OS Flow Flow Rate Rate vs. vs. Temperature Rise Rise 11.0 11.0 10.0 10.0 9.0 9.0 2.0 2.0 1.0 1.0 0.0 0.0 0 0 20 20 40 40 60 60 80 80 100 100 Temperature Rise Rise ( F) ( F) 9.0 T-H3-DV/OS Flow Flow Rate Rate vs. vs. Temperature Rise Rise 11.0 11.0 10.0 10.0 9.0 2.0 2.0 1.0 1.0 0.0 0.0 0 0 20 20 40 40 60 60 80 80 100 100 120 120 140 140 Temperature Rise Rise ( F) ( F)( F) Set temperature Set temperature 125 F 125 F (52 C) (52 C) or lower or lower Set temperature Set temperature 130 F 130 F (55 C) (55 C) or higher or higher Page Page 5 of56 of 6 www.takagi.com TRGSS01512

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters T-H3J-DV/OS PRESSURE LOSS T-H3-DV/OS T-H3S-DV/OS Specification Water heater(s) shall be Model as manufactured by Takagi Water Heaters, shall be a copper coil integral fin and tube construction with quick release brass or bronze waterways. Heater(s) will be factory assembled and tested. The heater shall be vented with 3 or 4 Schedule 40 PVC, CPVC, or ABS vent pipe, or stainless steel Category IV vent pipe at a distance not to exceed 70 (equivalent) for 3 vent or 100 (equivalent) for 4 vent, terminating vertically or horizontally as prescribed. Intake air pipe may be of such material as ABS, PVC, galvanized B-Vent, corrugated aluminum or stainless steel, or Category IV stainless steel not to exceed 70 (equivalent) for 3 vent or 100 (equivalent) for 4 vent. The heater(s) shall be controlled by an onboard solid-state printed circuit board monitoring incoming and outgoing temperatures with factory installed thermistors, sensing and controlling flow rate to set point temperature, controlling both air and gas mixture inputs to maintain thermal combustion efficiency. The heater(s) shall also consist of inline fusing, a spark ignition and sensor system, aluminized stainless steel burners, an air-fuel ratio sensor, a hi-limit temperature switch, modulating and proportional gas valves, a freeze protection sensor with ceramic heating blocks, and an overheat cutoff fuse. The water heater(s) shall be CSA listed, exceed the energy efficiency requirements of ASHRAE 90.1b-1992, and shall comply with SCAQMD Rule 1146.2 Ultra-Low NOx Standards. Copyright Takagi 2012 TAKAGI TANKLESS WATER HEATERS 500 Wald, Irvine, CA 92618 Toll Free: (888) 882-5244 Fax: (949) 770-3171 Printed in U.S.A. Page 6 of 6 www.takagi.com TRGSS01512