A and S Property Inspector



Similar documents
Vari Inspection Services

Georgia Home Inspection Services

PROPERTY INSPECTION REPORT

SWF Home Inspections

Inspection Tech. (330) Inspected By: Aaron Westerburg

Inspecton Report. Property Address:

Home Inspection Report

October 5, 2015 Dear Client,

COMPREHENSIVE PROPERTY INSPECTIONS

Self-Home Inspection Checklist

HOME INSPECTION CHECKLIST

CHRIS CURLES and ASSOCIATES INSPECTION SERVICES

A.C.E. Home Inspection Service St. Peters, MO (636)

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

PROPERTY INSPECTION REPORT Property Address:

Propery Inspection Report

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

Total Home Inspection Checklist

Home Inspection Report

Inspection Report. provided by: Delaware Property Inspection. Inspector: Richard Hiddemen (302)

Vision Home Inspection

Inspection Report Atlanta Strip Mall Commercial Building Property Address:

INSPECTION PROPERTY ADDRESS: Fort Bend County, Texas

SNS Home Inspections LLC

INVOICE. DATE: May 11, DESCRIPTION Inspection and report on a property located at OF SERVICES: Perfect Street, Sarasota, Fl.

Crawford Inspection Services C.C.B. #

South Carolina Home Inspector Standards of Practice

Open House and Home Tour Checklist

Quality Home Inspections, LLC 4433 Tennyson Street Denver, Colorado

COST OF WORK FORM. Abbreviations: ea = each, LF = linear feet, SF = square feet, HSF = square feet of living area (including garage conversion space)

Building Condition Assessment Report

Printed Monday, August 27, 2007 Inspected By: Michelle Teague. Client Information: Inspection, Condo City Lane Chicago, IL. Inspected 8/22/07 8:00 AM

Accurate Home Inspection of Illinois. Property Inspection Report For Steve & Jenny Hynek 210 W.Chicago Ave., Westmont, Illinois

HOMEOWNER S PERMIT GUIDE

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

Orlando Home Inspection Services

I NI NP R Inspected Items

#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check

Structure Survey Findings:

2. What building projects are exempted? (permit not required)

BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER

U.S. Department of Housing and Urban Development Office of Public and Indian Housing. A Good Place to Live!

Terry Jenkins, Owner Member, American Society of Home Inspectors Virginia Certified Home Inspector Certificate # , expires 1/2010

API America s Property Inspections

Real Estate Inspection Report

Arizona Health Care Association DISASTER PLANNING AND EMERGENCY MANAGEMENT GUIDE POST INCIDENT DAMAGE ASSESSMENT CHECKLIST

Inspection Report. Prepared For: Sampath Sample. Property Address: Waterside Drive. Alpharetta, GA Atlanta Home Inspections

Recommend that the dryer vent be cleaned annually to remove lint that may cause a fire.

Summit Series Single Section and Double Section Homes

License Requirements for Persons Engaging in the Business of Inspection Practice:

Code Enforcement Inspection Manual. City of Virginia Beach Department of Housing and Neighborhood Preservation Code Enforcement Division

Inspection Report. Dream Home Inspections Second Ave. Frisco CO (970)

A Seller s Guide to the Home Inspection By

Home Management Checklist: Spring

HOMEOWNER MAINTENANCE MANUAL

Inspection Report. Joe Smith. Property Address: 2222 SW 20 St Miramar FL Coast to Coast Property Inspections

INVENTORY AND CONDITION FORM CONCERNING THE PROPERTY AT

Final Walk-Through Checklist

Home Inspection Report

BUILDING ANALYSIS REPORT. John Doe 1234 Smith Road Atlanta, Georgia 30396

VIRGINIA HOME INSPECTIONS P.O.BOX 586 CHINCOTEAGUE ISLAND, VA PHONE

A TO Z HOME INSPECTIONS PROFESSIONAL HOME INSPECTION SERVICES FOR HOME BUYERS AND SELLERS

Inspecting to a higher standard.

GENERAL WIRING RULES FOR HOUSES

Building Permits: When are they required?

How To Insure Against Problems With Your Home Warranty

ROCK-SOLID Inspections

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: Inspection Date: Saturday, February XX, XXXX

OC Home Inspect. 333 S Crest Rd Orange, CA (714) guybrianadams@gmail.com Inspected By: Brian Adams

STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE:

Home Systems Data Inc E. Peakview Ave. Centennial CO

Inspection Report. Mr. Sample Sample. Property Address: 1234 USA Drive Indianapolis IN USA Drive. Morris Home Inspection Group, LLC

INSPECTION REPORT. Client Name Address From the inspection on: August XX, CHRIS LOWE

HOME INSPECTION REPORT

159 Morningside Avenue, Toronto

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

Schedule of Maintenance Fees

Estimating Database Checklist

Inspection Report. Prepared For: Atlanta Commercial Customer. Property Address: xxx Sandy Plains Road. Building 5 Marietta, GA 30066

Home Inspection Report

PROPERTY INSPECTION REPORT

Guaranteed Home Inspections HOME INSPECTION REPORT By Kurt Shafer Inspector of Properties

Pre-Drywall Inspection Report

EAST STROUDSBURG BOROUGH RESIDENTIAL RENTAL INSPECTION CHECK LIST

Building Condition Assessment Report

BUILDING INSPECTION REPORT

Simplify. Homeownership

Inspection Item COMMENTS

A Residential Owner s Guide to PERMITS. Elgin CITY OF PLANNING & NEIGHBORHOOD SERVICES

Transcription:

Cover Page A and S Property Inspector Property Inspection Report Inspection prepared for: xxxxx xxxxx Real Estate Agent:.. - Date of Inspection: 8/25/2014 Time: 10am Age of Home: 1999 Size: 1841 Weather: 86º sunny Inspector: Steven Montesano License # IOS.0001468-res 407 Park Way East 89106 Phone: 702-373-9519 Fax: 702-870-1293 Email: steve@aandsinspector.com www.aandsinspector.com

Report Summary Report Summary The summary below consists of potentially significant findings. These findings can be a safety hazard, a deficiency requiring a major expenses to correct or items I would like to draw extra attention to. The summary is not a complete listing of all the findings in the report, and reflects the opinion of the inspector. Please review all of the pages of the report as the summary alone does not explain all the issues. All repairs must be done by a licensed &bonded trade or profession. I recommend obtaining a copy of all receipts, warranties and permits for the work done. Page 1 of 34

We appreciate the opportunity to conduct this inspection for you! Please carefully read your entire Inspection Report. Call us after you have reviewed your report, so we can go over any questions you may have. Remember, when the inspection is completed and the report is delivered, we are still available to you for any questions you may have, throughout the entire closing process. Properties being inspected do not "Pass" or "Fail. - The following report is based on an inspection of the visible portion of the structure; inspection may be limited by vegetation and possessions. Depending upon the age of the property, some items like GFI outlets may not be installed; this report will focus on safety and function, not current code. This report identifies specific noncode, non-cosmetic concerns that the inspector feels may need further investigation or repair. For your safety and liability purposes, we recommend that licensed contractors evaluate and repair any critical concerns and defects. Note that this report is a snapshot in time. We recommend that you or your representative carry out a final walk-through inspection immediately before closing to check the condition of the property, using this report as a guide. Page 2 of 34

1. Attendance 2. Home Type 3. Occupancy Inspection Details In Attendance: None Present Client gave lock box code Home Type: Single Family Home Occupancy: Vacant Page 3 of 34

Grounds 1. Driveway and Walkway Condition Materials: Concrete driveway Concrete walkway Decretive block/ Brick walkway 2. Grading The home had areas of neutral or negative drainage at grade which will route runoff from precipitation to the foundation. The home had areas of neutral or negative drainage at grade which will route runoff from precipitation to the foundation. 3. Vegetation Observations Observed dead shrubs (Front) Observed excessive overgrowth from neighbors Observed excessive overgrowth from neighbors Page 4 of 34

4. Gate Condition Materials: Metal Wrought iron Gate requires adjustments 5. Patio and Porch Deck Observed uneven pavers this may be a potential TRIP HAZARD 6. Stairs & Handrail Observed uneven pavers this may be a potential TRIP HAZARD 7. Grounds Electrical Observed grounding rod not connected Some wires in ground not in conduit Observed grounding rod not connected Some wires in ground not in conduit Page 5 of 34

8. GFCI 9. Main Gas Valve Condition Materials: Main gas shut off located at outside meter 10. Plumbing 11. Water Pressure Materials: Undetermined 80 PSI 12. Pressure Regulator 13. Exterior Faucet Condition Location: Back of house Front of house Appears to be leaking at valve seal when in the open position, recommend repair for water conservation and to prevent possible water damage to structure/water intrusion if the hose is left on for extended period Appears to be leaking at valve seal when in the open position, recommend repair for water conservation and to prevent possible water damage to structure/water intrusion if the hose is left on for extended period 14. Balcony Page 6 of 34

15. Patio Enclosure 16. Patio and Porch Condition Materials: Some areas not visible from inspection level The porch roof is the same as main structure 17. Fence and wall Condition Materials: Block Observed efflorescence. This white powdery substance is left behind on the surface after water migrates through masonry Observed efflorescence. This white powdery substance is left behind on the surface after water migrates through masonry 18. Sprinklers Recommend a full evaluation of the system by a licensed technician Sprinkler lines leaking Observed sprinkler lines above grade Page 7 of 34

19. Grounds Condition Sprinkler lines leaking 20. Water Well Condition 21. Septic System Condition Page 8 of 34

1. Doors 2. Window Condition Exterior Areas Some window locks need adjustment. 3. Security Bars/Doors 4. Siding Condition Materials: Stucco veneer MAINTANCE TIP: Caulk and seal all gaps, cracks and openings Observed normal/ moderate cracks 5. Patio Doors MAINTANCE TIP: Caulk and seal all gaps, cracks and openings 6. Screen Doors 7. Satellite/Cable condition Observed cover to exterior main panel not installed Page 9 of 34

8. Exterior Conditions Observed cover to exterior main panel not installed Page 10 of 34

1. Slab Foundation Foundation 2. Foundation Perimeter 3. Foundation Walls 4. Cripple Walls 5. Foundation Plumbing 3/4 INCH 6. Sump Pump 7. Crawl Space Condition 8. Ventilation 9. Vent Screens 10. Access Panel 11. Post and Girders Page 11 of 34

1. Roof Condition Roof Materials: Inspected from ground level with binoculars. Some areas not visible from inspection level. Materials: Concrete tiles noted. Observed loose tiles. 2. Flashing Observed loose tiles. 3. Soffit/fascia Condition 4. Eaves & Facia 5. Penetration Condition 6. Ventilation 7. Vent Screens O Hagen vents Gable vents Page 12 of 34

8. Gutters 9. Spark Arrestor 10. Chimney Page 13 of 34

1. Electrical Panel 2. Main Amp Breaker Electrical Location: Exterior of structure Location: No Sub Panels located 225 amp 3. Breakers in off position 0 4. Cable Feeds 5. Breakers 6. Condition Materials: Romex Materials: Copper 7. Service Entrance Conditions 8. Fuses Materials: No fuses in this property. 9. General Condition Page 14 of 34

1. Walls Condition Garage 2. Floor Condition 3. Rafters & Ceiling Materials: Bare concrete Limited review due to finished ceiling 4. Electrical Condition 5. GFCI Suggest replacing GFIC in garage for better operation. 6. 240 Volt Suggest replacing GFIC in garage for better operation. 7. Exterior Door 8. Fire Door Page 15 of 34

9. Garage Door Condition Materials: Sectional door Dented in areas Door locked not inspected Dented in areas 10. Garage Door Parts Door locked not inspected Door locked not inspected 11. Garage Opener Status Door locked 12. Garage Door's Reverse Status Door locked 13. Ventilation 14. Vent Screens 15. Cabinets 16. Counters Page 16 of 34

17. Wash Basin 18. Car Port Condition Page 17 of 34

1. Base Water Heater Noted no overflow drain pan under unit, This is to protect base. 2. Heater Enclosure 3. Venting Noted no overflow drain pan under unit, This is to protect base. 4. Water Heater Condition Heater Type: Gas Location: The heater is located in the garage. 5. TPRV 6. Number Of Gallons 7. Gas Valve 50 gallons 8. Plumbing Materials: Copper Aluminum Page 18 of 34

9. Strapping The water heater is not strapped. By todays standards the water heater requires two 1 1/2" steel straps 16 gauge, 1/3 from the top and the bottom. The water heater is not strapped. By todays standards the water heater requires two 1 1/2" steel straps 16 gauge, 1/3 from the top and the bottom. 10. Electrical Condition Page 19 of 34

Interior Areas The Interior section covers areas of the house that are not considered part of the Bathrooms, Bedrooms, Kitchen or areas covered elsewhere in the report. Interior areas usually consist of hallways, foyer, and other open areas. Within these areas the inspector is performing a visual inspection and will report visible damage, wear and tear, and moisture problems if seen. Personal items in the structure may prevent the inspector from viewing all areas on the interior. The inspector does not usually test for mold or other hazardous materials. A qualified expert should be consulted if you would like further testing. 1. Bar 2. Cabinets 3. Ceiling Fans 4. Closets 5. Door Bell 6. Doors Some threshold missing/damaged. 7. Electrical 8. Security Bars 9. Smoke Detectors Smoke detector was chirping, this indicates the battery needs to be replaced. 10. Stairs & Handrail Page 20 of 34

11. Window/Wall AC/Heat 12. Ceiling Condition 13. Wall Condition 14. Fireplace 15. Floor Condition 16. Plumbing Materials: There are drywall ceilings Materials: Drywall Materials: Living Room Materials: Gas Not inspected, pilot not able to light Flooring Types: Tile Wood flooring Materials: Undetermined. Page 21 of 34

1. Locations 2. Cabinets 3. Counters 4. Dryer Vent 5. Electrical 6. GFCI 7. Exhaust Fan 8. Gas Valves 9. Wash Basin 10. Floor Condition 11. Plumbing Locations: Hall Materials: Tile Laundry 12. Wall Condition Materials: Drywall walls noted. Page 22 of 34

13. Ceiling Condition Materials: There are drywall ceilings noted. 14. Washer/Dryer condition Not tested/inspected Page 23 of 34

Heat/AC The heating, ventilation, and air conditioning and cooling system (often referred to as HVAC) is the climate control system for the structure. The goal of these systems is to keep the occupants at a comfortable level while maintaining indoor air quality, ventilation while keeping maintenance costs at a minimum. The HVAC system is usually powered by electricity and natural gas, but can also be powered by other sources such as butane, oil, propane, solar panels, or wood. The inspector will usually test the heating and air conditioner using the thermostat or other controls. If the air temperature out side is above 65 the testing of the heat may damage the unit therefore it will not be tested. If the temperature out side is below 65 the testing of the A/C may damage the unit therefore it will not be tested. For a more thorough investigation of the system please contact a licensed HVAC service person. 1. Heater Condition Materials: The furnace is located in the attic Materials: Gas fired forced hot air. Recommend heating-a/c contractor to evaluate. Observed furnace cover loose at unit 2. Heater Base Observed furnace cover loose at unit 3. Enclosure 4. Venting 5. Gas Valves Page 24 of 34

6. Refrigerant Lines 7. AC Compress Condition Compressor Type: 5 Ton Unit(s) Location: The compressor is located on the exterior grounds. 8. Air Supply 9. Registers 10. Filters 11. Thermostats Location: Located inside a filter grill in the hall ceiling. MAINTENANCE TIP: The air filter(s) should be inspected at least monthly and cleaned or replaced as required. There are two types of filters commonly used: (1) Washable filters, (constructed of aluminum mesh, foam, or reinforced fibers) these may be cleaned by soaking in mild detergent and rising with water. Or (2) Fiberglass disposable filters that must be REPLACED before they become clogged. Remember that dirty filters are the most common cause of inadequate heating or cooling performance. The furnace filter is dirty. Filters help clean the house air, making the environment more pleasant. Filters also clean the air before it passes through the blower and heat exchanger. This helps to keep these furnace components working efficiently. It is recommended to change the filter and then regular inspection & maintenance is advised. 12. Swamp Cooler Condition Page 25 of 34

Kitchen The kitchen is used for food preparation and often for entertainment. Kitchens typically include a stove, dishwasher, sink and other appliances. 1. Cabinets 2. Counters 3. Dishwasher Installation is incomplete. Not tested not plugged in 4. Garbage Disposal 5. Microwave Light under microwave not operational. 6. Cook top Condition 7. Oven Condition 8. Range Condition 9. Sinks 10. Vent Condition 11. Floor Condition Faucet loose at sink Materials: Part of Microwave Materials: Tile Page 26 of 34

12. Wall Condition Materials: Drywall walls noted. 13. Plumbing 14. Ceiling Condition Materials: There are drywall ceilings noted. 15. Electrical 16. GFCI 17. Refrigerator Condition 18. Trash Compactor Page 27 of 34

Bedrooms The main area of inspection in the bedrooms is the structural system. This means that all walls, ceilings and floors will be inspected. Doors and windows will also be investigated for damage and normal operation. Personal items in the bedroom may prevent all areas to be inspected as the inspector will not move personal items. 1. Locations Locations: Master bedroom#1 Bedroom 2 Bedroom 3 Optional room 2. Cabinets 3. Ceiling Fans 4. Closets 5. Electrical 6. Floor Condition 7. Wall Condition Flooring Types: Tile Wood flooring. Floor is not level. Suggest further evaluation by a licensed contractor Materials: Drywall walls noted. 8. Window-Wall AC or Heat 9. Ceiling Condition Materials: There are drywall ceilings 10. Doors Page 28 of 34

Bathroom Bathrooms can consist of many features from jacuzzi tubs and showers to toilets and bidets. Because of all the plumbing involved it is an important area of the house to look over. Moisture in the air and leaks can cause mildew, wallpaper and paint to peel, and other problems. The home inspector will identify as many issues as possible but some problems may be undetectable due to problems within the walls or under the flooring.. 1. Locations 2. Cabinets Locations: Master Bathroom Hall bathroom 3. Ceiling Condition 4. Counters Materials: There are drywall ceilings Granite/Corian Caulk backsplash to prevent water penetration. 5. Electrical 6. GFCI 7. Exhaust Fan 8. Floor Condition Exhaust fan is noisy. (master bath) Materials: Tile Base board damage Page 29 of 34

9. Heating 10. Plumbing 11. Showers Base board damage Visible leaking noted under the sink. We recommend contacting a licensed plumbing contractor for repair options. Maintenence Tip: Caulk and seal shower to floor area to prevent moisture penetration. Low water flow at shower heads. Regrout tub/shower area as required Regrout tub/shower area as required Page 30 of 34

12. Shower Walls 13. Bath Tubs Tile Regrout tub/shower area as required Caulk and seal tub and shower area to prevent moisture penetration. Loose tub fill spout. 14. Enclosure 15. Sinks Loose tub fill spout. Caulk and seal around enclosure as needed Recommend review for repair or replacement as necessary. Stopper is missing/inoperable. Drain line leaks under sink. Page 31 of 34

16. Toilets Drain line leaks under sink. The toilet tank is loose. (Hall bath) 17. Doors Page 32 of 34

1. Access Attic 2. Structure 3. Duct Work Air leaking at plenum. 4. Electrical Air leaking at plenum. 5. Attic Plumbing 6. Insulation Condition Materials: Blown in fiberglass insulation noted. Depth: Insulation averages about 8-10 inches in depth 7. Exhaust Vent Exhaust fan duct in attic bent Page 33 of 34

8. General Condition Exhaust fan duct in attic bent Page 34 of 34