How To Use Lead Block



Similar documents
09990 MOLD REMEDIATION, LEAD-BASED PAINT ABATEMENT AND ENCASEMENT OF ASBESTOS

Product Information/Specifications

Acrylic Enamel Topcoat

Essential Maintenance For a Lead-Safe Home

Getting Started Different Ways of Deleading Other Options and Resources

General Surface Preparation

BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION

Minor Cracks in Horizontal Surfaces

Tractor Painting Tips

BLACK JACK ALL WEATHER ROOF COATING

Carpet Seam Sealer 8200

Colorado State University. Durrell Center Roof Repair

State of Illinois Illinois Department of Public Health OUT. Homeowner s Lead-based Paint Abatement Guide

Primer-Sealers Solutions

Standard Method for Sampling and Analysis of. of Chlorine Containing Bleaches. Soap Products

Successful Painting Jobs Start Here.

Document Library TS Data Sheet

METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES

TECHNICAL DATA RS European Clear EZ N. Webster Street Dayton, OH Phone Toll Free Fax

family of products is really Reichhold s answer to the growing need to meet more stringent regulations and performance requirements.

Specifications. PermaTone, Inc. Manufacturer s Long Form Specifications Interior Finish Coatings PF-405

RECOATING AND RENEWING SPF ROOFING SYSTEMS

Newfoundland and Labrador Paint Recycling Program Guidelines

T R A N S F E R A B L E F U L LY

Asbestos WHAT TO DO? Studies of people who were exposed to high levels of asbestos in factories and shipyards, are at increased risk of:

RockSolid Deck Restoration Application

The Minnesota Lath and Plaster Bureau Repairing Cracks in Stucco

Application of Exterior Wood Finishes

GENERAL PROVISIONS

A. Work on this project shall consist of, but is not limited to, the following:

RAPTOR TRUCK BED LINER - BLACK

WARRANTY VINYL SIDING CERTAINTEED CORPORATION LIFETIME LIMITED

SMOOTHMOVE INSTRUCTIONS FURNITURE VAN EPOXY FLOOR FINISH KIT VOC-FREE - NO SOLVENT GENERAL INFORMATION KEY 87269AB

HOMEOWNER MAINTENANCE MANUAL

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

SC2000 CEMENT BONDING PROCEDURES

DuPont ChromaOne Acrylic Urethane Single Stage

Stucco Repair and Maintenance No. 1.01

Cleaning guide for senior living facilities

Product Information/Specifications

ASBESTOS SCIENCE TECHNOLOGIES, INC.

Contents. Introduction...3. Determine the Type of Floor Finishing Project...4. Things to Think About Before You Start...5. Assemble Materials...

PHOENIX Product Data Sheet (Updated on 14-Jan-2012)

MARTIN TESTING LABORATORIES (MTL) PAINTS AND COATINGS TESTING CAPABILITIES

Lead Exposure Management Plan

Dow Corning AllGuard Silicone Elastomeric Coating. Application and Maintenance Guide

Aspect Metal Peel & Stick Tile Installation Guide

[Note: This guide specification may be used for Polomyx All-Acrylic, Polomyx Waterbase and Zolatone Waterbase multicolor finishes.

BRIDGE FIELD PAINTING, REPAINTING, 412 AND PAINT RESIDUE CONTAINMENT. A. Field Painting, Bridge Repainting and Residue Containment:

Asbestos. from the Home. Removing. Read this booklet for:

CENTER FOR ENVIRONMENTAL HEALTH Emergency Response/Indoor Air Quality Program

Technical Data MasterFormat TexSton IMPASTO

Bathroom Installation Guide

Sto Specification No. RC100 Guideline Specifications for Cleaning Wall Surfaces

Surface Information and Preparation Data Sheet (SIPDS) SIPDS No. 1 Interior Wallboards - walls and ceilings

THERMOTEK SELF ADHESIVE MEMBRANE +G2 OVER WOOD SYSTEM DESCRIPTION SELF ADHESIVE OVER WOOD (8YR) BS-SA/CS

Cleaning Guidelines Range Refrigerators Dishwasher Kitchen Exhaust Fans Cabinets and Drawers Plumbing Fixtures Light Fixtures

CONDITION OF QUALITY ITEMS

bout your HOUSE before you start Repairing And Replacing Materials Exterior Walls

The Rehab Inspector and LBP

DUST AND DEBRIS MANAGEMENT PROCEDURES HPD HOUSING REHABILITATION PROGRAMS

Joseph Laquatra Cornell University

VINYL SIDING CERTAINTEED CORPORATION L I M I T E D

BENTLEY ELEMENTS COLLECTION LVT

Hardwood Maintenance. WORKBOOK and TIPS of the TRADE

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method F (100 C) calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Cleaning up after sewage backup

INDUSTRIAL FLOORING INSTALLATION CHALLENGES. James C. Ziegler, ArmorSeal Product Manager Sherwin Williams Cincinnati, Ohio, USA

LEAD-BASED PAINT HAZARD POLICY

LACAVA. Table of Contents. Owner s Manual. Wall-mounted & Vessel Sinks PS#:

SECTION PAINTS AND COATINGS. Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text".

TECHNICAL DATA SHEET HAMMERITE METAL PAINT. Smooth Hammered Satin Aerosol

Mold. Clean Up, Removal, Safety Concerns

3M Scotchkote Urethane Coating 165HB

POLYURETHANE LINING AND COATING ON PIPE RAW WATER

SCHWARTZ WATER-BASE WOOD FLOOR SEALER AND WATER-BASE PREMIIUM WOOD FLOOR FINISH

GigaCrete Specification PlasterMax

THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER

Sun Windows General Information Sun New Construction Window Installation Instructions

Technical Data SeaQueen

Barewood Octagon and Elongated Windows Installation Instructions

Basement Window Installation Guide Hopper and Sliding

Bath Fixtures. Mirrors. Showers. Care and Maintenance. General Care Guidelines. Bathtubs

SCENIC VIEW SV 10 SECTION SOLAR CONTROL FILMS

1bathrooms. bathrooms PulteGroup, Inc. All Rights Reserved.

3.8 HSP (High Solids Polyurethane)

TRUWOOD REVERSIBLE TRIM

Former National Guard Armory Cherokee, Oklahoma Remediation Final Report

Mold and Mildew Mold and mildew can be detected by sight, smell and touch.

GUIDE SPECIFICATION COMBINATION SURFACE SYSTEM FOR NEW HOT MIX ASPHALT TENNIS COURTS I. PART 1 - GENERAL

Acrylic Coatings: The Perfect Stucco Finish

Metal Rescue Rust Remover Technical Data

UNILIC ACRYLIC EMULSION

PROPOSED SCOPE OF WORK Repair Building 1005 Exterior & Interior, New Post Chapel 25 April 2005

AUTO COLLISION REPAIR CERTIFICATE I COURSE DESCRIPTIONS. Total: 18 Credit Hours

Asbestos Work Permit Procedures

REPAIR MANUAL MATERIALS

Cold trichloroethylene degreasing Film Thickness 70± 10 µm 10 minutes at 170 C (PZ 770 alone) 5 minutes 30 sec. at 220 C (maximum curing conditions)

GENERAL MAINTENANCE MANUAL

Transcription:

Commonwealth of Massachusetts -Department of Public Health Childhood Lead Poisoning Prevention Program Donovan Health Building, 1st floor Randolph St. Canton Ma 02021 REGISTER OF APPROVED ENCAPSULANT PRODUCTS PAGE 1 Encapsulants are coatings applied in liquid forms that are made to be long-lasting barriers over lead paint. Conventional paint is not an encapsulant. Only the products listed on this Register are approved for use in Massachusetts, pursuant to the regulations for Lead Poisoning Prevention and Control, 105 CMR 460.000. Each approved encapsulant product will bear the D/L Laboratories seal of approval. The products listed on this Register have Massachusetts approval for lead paint abatement on interior surfaces with wooden, plaster, metal or masonry substrates. Encapsulant use is prohibited on floors, stair treads, thresholds, any exterior surface, as well as the sashes, parting beads, window wells, and the interior/exterior or header stops of moveable windows for regulatory compliance. Product Name Manufacturer Not Recommend for use on: Required Dry Film Thickness Respiratory Protection Required Occupancy During Application L-B-C Lead Barrier Compound Type III also known as Childguard Fiberlock Technologies, Inc. 150 Dascomb Road Andover, MA 01810 (978) 623-9987 (800) 342-3755 www.fiberlock.com Walls with chalking or calcimine Ceilings with calicmine Working radiators which exceed 240 0 F. Friction and Impact surfaces of doors and windows. 7 mils minimum For spray application, use molded polymesh shell dust and mist respirator- MSHA, NIOSH Approval No. TC- 21C-287 or equivalent Occupants must be out during the day for spray application only. Occupants may be in residence but not in room or work area undergoing encapsulation if brush or roller is used. Use adequate ventilation during the first 24 hours after application. Lead Block Complementary Coatings Corp. 101 Paragon Dr., Montvale, NJ 07645 800-225-5554 Walls with chalking or calcimine Door jambs Window sills Ceilings with calcimine Working radiators If not top coated with alkyd or latex enamel, handrails, railing caps, cabinets and drawers Friction surfaces 14 to 16 mils minimum SAME AS ABOVE SAME AS ABOVE Insl-Cap Lead Encapsulating Compound Complementary Coatings Corp. 101 Paragon Dr., Montvale, NJ 07645 800-225-5554 Walls with chalking or calcimine Door jambs Ceilings with calcimine Working radiators Friction surfaces 7 mils minimum SAME AS ABOVE SAME AS ABOVE REFERENCES: Deciding Whether to Encapsulate by Childhood Lead Poisoning Prevention Program Care and Maintenance of Encapsulants by Childhood Lead Poisoning Prevention Program Encapsulants: Guidelines for Tenants and Property Owners by Childhood Lead Poisoning Prevention Program Massachusetts General Law MGL c. 111, 189A through 199B (the Lead Law) Regulations for Lead Poisoning Prevention and Control (105 CMR 460.000) FOR MORE INFORMATION: Please call the Childhood Lead Poisoning Prevention Program at 1 (800) 532-9571 or 781-774-6611 (out of state); www.mass.gov/dph/clppp

Commonwealth of Massachusetts -Department of Public Health Childhood Lead Poisoning Prevention Program Donovan Health Building, 1st floor Randolph St. Canton Ma 02021 REGISTER OF APPROVED ENCAPSULANT PRODUCTS PAGE 2 Encapsulants are coatings applied in liquid form, which are made to be long-lasting barriers over lead paint. Conventional paint is not an encapsulant. Only the products listed on this Register are approved for use in Massachusetts, pursuant to the regulations for Lead Poisoning Prevention and Control, 105 CMR 460.000. Each approved encapsulant product will bear the D/L Laboratories seal of approval. The products listed on this Register have Massachusetts approval for lead paint abatement on interior surfaces with wooden, plaster, metal or masonry substrates. Encapsulant use is prohibited on floors, stair treads, thresholds, any exterior surface, as well as the sashes, parting beads, window wells, and the interior/exterior or header stops of moveable windows for regulatory compliance. Product Name Manufacturer Not Recommended for use on: Required Dry Film Thickness Respiratory Protection Required Occupancy During Application LEADSTOP L-B-C Lead Barrier Compound Type I Complementary Coatings Corp. 101 Paragon Dr., Montvale, NJ 07645 800-225-5554 Fiberlock Technologies, Inc. 150 Dascomb Road Andover, MA 01810 (978) 623-9987 (800) 342-3755 www.fiberlock.com Walls with chalking or calcimine Door jambs Window sills Ceilings with calcimine Working radiators If not top coated with alkyd or latex enamel, handrails, railing caps, cabinets and drawers Friction surfaces Walls with chalking or caclimine Ceilings with calicmine Working radiators which exceed 240 o F. Friction and impact surfaces of doors and windows. 14 to 16 mils minimum 7 mils minimum SAME AS ABOVE SAME AS ABOVE SAME AS ABOVE SAME AS ABOVE SE-110 MS (multi-purpose primer) Penetrating- Stabilizer and SE-120 (top coat) Protective- Skin. Contact the manufacturer regarding availability through approved distributors and contractors. SAFE Encasement Systems 4344 San Cascina St. Las Vegas, NV 89145 (888) 277-8834 www.safeencasement. com Walls with chalking or calcimine Ceilings with calcimine Friction and impact surfaces SE-110-5 mills SE-120-7 mills minimum SAME AS ABOVE SAME AS ABOVE Revised 6/16/2000 for SAFE Encasement Systems Revised 11/22/2010

Commonwealth of Massachusetts - Department of Public Health Childhood Lead Poisoning Prevention Program (CLPPP) Donovan Health Bldg, 1 st flr. Randolph at Canton, MA 02021 ENCAPSULANT PRODUCT FACT SHEET Encapsulants are coatings applied in liquid form that are made to be long-lasting barriers over lead paint. Conventional paint is not an encapsulant. The Regulations for lead poisoning prevention require a lead inspection and a surface assessment be performed before encapsulants are applied. The Regulations allow encapsulants to be applied by a Licensed Deleading Contractor, a homeowner or a homeowner s agent. If a homeowner or his/her agent will be applying the encapsulant, they must first be authorized by CLPPP by reading a training booklet taking a quiz, and mailing or faxing the quiz to CLPPP (781.774. 6700). Contact CLPPP for more information at 1-800-532-9571 or www.mass.gov/dph/clppp The use of properly applied encapsulant products with the D/L Laboratories seal of approval can satisfy Massachusetts requirements for lead paint abatement. The product named on this Fact Sheet has Massachusetts approval for deleading. NAME: LBC Lead Barrier Compound Type III or Childguard REQUEST MSDS FROM: www.fiberlock.com Fiberlock Technologies, Inc. 150 Dascomb Road, Andover, MA 01810 PRODUCT DESCRIPTION: DL-12362 Type: elastomeric-thermoplastic water-based copolymer Finish: Architectural Matte Color(s): white, antique linen, black Tintable: Yes - contact manufacturer Dilutable: no Mixable with Another Product: no Paintable: yes Sizes: 1, 5, 55 U.S. gallon containers Disposal: in accordance with local, state and federal regulations Application Equipment: airless spray (best), brush, roller Mixing: ready to use, mix thoroughly Dry Time: 2-4 hrs (to touch) Full Cure: 30 days Type of Cure: coalescence Flash Point: none VOC: 88 grams per liter Clean-Up: warm, soapy water Spreading Rate to Achieve Required 7 Mils Dry Film Thickness No.Coats Thickness Per Wet Coat Thickness Per Dry Coat Spreading Rate Per Wet Coat Brush or Roller 2 7 mils 3-4 mils 240 sq.ft./gal Airless Spray 1 14 mils 7-8 mils 120 sq.ft./gal Spreading Rate to Achieve Required Dry Film Thickness - 120 sq.ft./gal Note: Spreading rate does not include any loss during application process. RECOMMENDED USES: WALLS: walls, chair rails, baseboards DOORS: doors, casings WINDOWS: sills, aprons, casings CEILINGS: ceilings without calcimine STAIRS: risers, railing caps, handrails, balusters, newel posts, stringers OTHER: curved wooden surfaces CABINETS: nonfriction surfaces DRAWERS: nonfriction surfaces USES NOT RECOMMENDED: WALLS: walls with chalking or calcimine DOORS: door jambs WINDOWS: (see prohibited list) CEILINGS: ceilings with calcimine OTHER: radiators over 180 F, friction surfaces CABINETS: friction surfaces DRAWERS: friction surfaces PROHIBITED: floors, stair treads, thresholds, any exterior surface, as well as the sashes, parting beads, window wells, and the interior/exterior or header stops of moveable windows.

SURFACE PREPARATION: Prior to application of LBC Lead Barrier Compound Type III/ChildGuard, inspect all surfaces to insure that they are clean, dry and free of all foreign matter including dust, rust, grease, oil, mildew, glue size, calcimine, wax, soap, loose paint, etc. Patch and repair irregularities in surfaces with prepared vinyl patch or appropriate patching compound. Use Fiberlock Technologies, Inc. Power Block or any other stain-blocking primer for surfaces which have been water-damaged or discolored. For high-gloss or newly painted surfaces, wet scour with a strong detergent or surface preparation treatment, using a course scouring pad to eliminate any gloss. Thoroughly remove by washing any residual scouring material, detergent or other surface preparation material, and dry completely prior to application. Wear gloves and protective eye wear if using caustics. See manufacturers specifications for information on other surface conditions (e.g. rust, efflorescence, etc.) ENCAPSULANT APPLICATION: Apply with airless spray equipment for best results. Adjust G.P.M. and P.S.I. setting and tip size according to the production and control requirements of the job and the skill of the applicator. Smaller pumps using smaller tips at higher P.S.I. settings are better suited for jobs requiring higher accuracy and greater control. Larger pumps using larger tips at lower P.S.I. settings produce higher production application for large, open jobs, but require a higher level of application skill. Apply by brush or roller at 240 sq ft/gal for 7 mils (wet) and 3-4 mils (dry) per coat. Apply liberally and uniformly with a polyester or polyester/nylon brush to woodwork and trim. Use a wet mil gauge to control thickness (a wet mil gauge is available from the manufacturer). Multiple coats may be necessary to achieve required 7 mils dry thickness. Allow each coat to dry before applying additional coats. Use a trim brush to achieve a smooth finish on trim work. OCCUPANCY DURING APPLICATION: Occupancy is permitted during brush or roller application, but not in room or interior space being encapsulated. For spray application, occupancy is prohibited during the day for worksite safety reasons. Occupants may return at the end of the workday. OCCUPANCY AFTER APPLICATION: Yes. Use adequate ventilation for first 24 hours after application. CAUTIONS: Use with adequate ventilation. If respiratory irritation develops, increase ventilation or wear respiratory protection. Use molded polymesh shell dust and mist respirator - MSHA, NIOSH Approval No. TC-21C-287 or equivalent - during spray application. Avoid contact with eyes and skin. Wash hands thoroughly with soap and water after using. During application, wear gloves and safety glasses or goggles. WARRANTY: LBC Lead Barrier Compound Type III/ChildGuard has a 20-year minimum warranty with certain limitations. (See product label.) Notify Fiberlock Technologies, Inc. within 45 days of purchase to advise of any suspected manufacturing defects. CARE AND MAINTENANCE: LBC Lead Barrier Compound Type III/ChildGuard will not prevent exposure to the encapsulated leadbased paint if surface is damaged, broken or abraded. Surfaces coated with L-B-C Lead Barrier Compound Type III/ChildGuard must be inspected routinely for holes, cracks, dents, peeling surfaces, bubbles, and any other defect, including water damage. Damaged surfaces should be repaired and re-encapsulated immediately to prevent exposure to the lead hazard. REFERENCES: Deciding Whether to Encapsulate by Childhood Lead Poisoning Prevention Program Register of Approved Encapsulants by Childhood Lead Poisoning Prevention Program Care and Maintenance of Encapsulants by Childhood Lead Poisoning Prevention Program Material Safety Data Sheet (MSDS) for LBC Lead Barrier Compound Type III/ChildGuard by Fiberlock Technologies, Inc. LBC Lead Barrier Compoun/ChildGuard Label from Container by Fiberlock Technologies, Inc. Massachusetts General Law (MGL) c. 111, Sect. 189A-199B (the Lead Law) Regulations for Lead Poisoning Prevention and Control (105 CMR 460.000) FOR MORE INFORMATION OR PROBLEM RESOLUTION, CALL OR EMAIL: Fiberlock Technologies, Inc. at 800-342-3755 or 978.623.9987 or info@fiberlock.com Childhood Lead Poisoning Prevention Program at 1-800-532-9571 or 781-774-6711 (out of state) The Licensed Deleader, who applied the encapsulant. If homeowner or agent applied product, you may wish to call a Licensed Deleader for advice or assistance. Rev 7/25/96 Revised 11/22/2010

Commonwealth of Massachusetts - Department of Public Health Childhood Lead Poisoning Prevention Program (CLPPP) Donovan Health Bldg, 1 st floor, Randolph at Canton, MA 02021 ENCAPSULANT PRODUCT FACT SHEET Encapsulants are coatings applied in liquid form that are made to be long-lasting barriers over lead paint. Conventional paint is not an encapsulant. The Regulations for Lead Poisoning Prevention and Control require a lead inspection and a surface assessment be performed before encapsulants are applied. The Regulations allow encapsulants to be applied by a Licensed Deleading Contractor, a homeowner or a homeowner s agent. If a homeowner or his/her agent will be applying the encapsulant, they must first be authorized by CLPPP by reading a training booklet taking a quiz, and mailing or faxing the quiz to CLPPP (781.774. 6700). Contact CLPPP for more information at 1-800-532-9571 or www.mass.gov/dph/clppp The use of properly applied encapsulant products with the D/L Laboratories seal of approval can satisfy Massachusetts requirements for lead paint abatement. The product named on this Fact Sheet has Massachusetts approval for deleading. NAME: Lead Block REQUEST MSDS FROM: www.msds.com 101 Paragon Dr., Montvale, NJ 07645 / 800-225-5554 PRODUCT DESCRIPTION: DL-10019 Type: modified acrylic elastomeric resin Mixing: ready to use, mix thoroughly Finish: eggshell Color(s): decorator white, colors Dry Time: 4-12 hrs (to touch) Tintable: yes - contact manufacturer Dilutable: no Full Cure: 14 days Mixable with Other Products: no Paintable: yes (with alkyd or latex enamel) Type of Cure: coalescence/crosslinking Sizes: 1 and 5 U.S. gallon containers Flash Point: none Disposal: same as latex paint (follow local ordinances) VOC: < 100 grams per liter Application Equipment: airless spray (best), brush, roller Clean-Up: warm, soapy water Spreading Rate to Achieve Required 14-16 Mils Dry Film Thickness Premier Coatings, Inc. No.Coats Thickness Per Wet Coat Thickness Per Dry Coat Spreading Rate Per Wet Coat Brush or Roller 3-4 8-10 mils 4-5 mils 200 sq.ft./gal Airless Spray 2 14-16 mils 7-8 mils 100 sq.ft./gal Spreading Rate to Achieve Required Dry Film Thickness - 50 sq.ft./gal Note: Spreading rate does not include any loss during application process. RECOMMENDED USES: WALLS: walls, chair rails, baseboards DOORS: doors, casings WINDOWS: aprons, casings CEILINGS: ceilings without calcimine STAIRS: balusters, newel posts, stringers. Topcoat of alkyd or latex enamel required for railing caps, handrails OTHER: curved wooden surfaces, nonworking radiators CABINETS: nonfriction surfaces, topcoat of alkyd or latex enamel required DRAWERS: nonfriction surfaces, topcoat of alkyd or latex enamel required USES NOT RECOMMENDED: WALLS: walls with chalking or calcimine DOORS: jambs WINDOWS: (see prohibited list) CEILINGS: ceilings with calcimine OTHER: working radiators, friction surfaces CABINETS: friction surfaces DRAWERS: friction surfaces PROHIBITED: floors, stair treads, thresholds, any exterior surface, as well as the sashes, parting beads, window wells, and the interior/exterior or header stops of moveable windows.

SURFACE PREPARATION: Comply fully with product specifications. All surfaces must be clean, sound, dry and free of dust, rust, grease, oil, mildew and loose particles before application. A licensed deleader must remove all flaking and peeling paint down to a sound surface. Repair damage with a joint compound and smooth over with a damp sponge to remove excess compound and blend into surrounding wall surface. Remove all oil, grease, wax, smoke residues and other contaminants by washing with a suitable cleaner and rinsing with clean water. Remove mildew by washing with a solution of TSP (tri-sodium phosphate) in one gallon of water and add one quart of commercial bleach. Wear gloves and protective eye wear if using bleach solutions. For high-gloss surfaces, wet scour with TSP or a strong detergent substitute and water solution using coarse steel wool to eliminate any gloss. Thoroughly remove by washing any residual scouring material, detergent or other surface preparation material, and dry completely prior to application. Although no special primers are required, there may be occasions where a primer would be beneficial in the overall performance of the coating: prime water stains with stain blocking primer; prime chalking with penetrating chalk primer; prime bare wood with an enamel undercoater; prime drywall with a quality acrylic primer and sealer. ENCAPSULANT APPLICATION: Apply in multiple coats. Achieve total thickness of 32-36 mils (wet), but do not exceed 36 mils. Use wet mil gauge when applying product. Do not apply if ambient temperature is below 45 F. Airless spray application in two coats (each 14-16 mils) is recommended for best results, including a smoother dry film. Use.017 to.019 inch orifice and a 60 mesh screen. If applied with a brush or roller, multiple coats are required to achieve required thickness. Expect 6-8 wet mils/coat by brush and 8-12 wet mils/coat by roller. Use a polyester or polyester/nylon brush. Use a high quality tapered trim brush with a filament density to achieve a smooth finish on all trim work. Application to a large smooth or any size rough area should be performed with a quality roller cover with a 1/2 to 3/4 inch nap. Regular paint topcoats may be applied over surfaces that have been sprayed, rolled or brushed with Lead Stop OCCUPANCY DURING APPLICATION: Occupancy is permitted during brush or roller application, but not in room or interior area being encapsulated. For spray application, occupancy is prohibited during the day for worksite safety reasons only. Occupants may return at the end of the workday. OCCUPANCY AFTER APPLICATION: Yes. Use adequate ventilation for first 24 hours after application. CAUTIONS: Use with adequate ventilation. If respiratory irritation develops, increase ventilation or wear respiratory protection. Use molded polymesh shell dust and mist respirator - MSHA, NIOSH Approval No. TC-21C-287 or equivalent - during spray application. Avoid contact with eyes and skin. Wash hands thoroughly with soap and water after using. During application wear gloves and safety goggles. WARRANTY: Lead Block has limited product liability for 20 years. The purchaser shall notify Complementary Coatings Corp. within 30 days after any damage arising out of any defect in manufacturing. CARE AND MAINTENANCE: Lead Block will not protect occupants from ingestion of the encapsulated lead-based paint if surface is damaged, broken, or abraded. Surfaces coated with Lead Block must be inspected routinely for holes, cracks, dents, peeling surfaces, bubbles, and any other defect, including water damage. Damaged surfaces should be repaired and re-encapsulated immediately to prevent exposure to the lead hazard. REFERENCES: Deciding Whether to Encapsulate by Childhood Lead Poisoning Prevention Program Register of Approved Encapsulants by Childhood Lead Poisoning Prevention Program Care and Maintenance of Encapsulants by Childhood Lead Poisoning Prevention Program Material Safety Data Sheet (MSDS) for Lead Block by Complementary Coatings Corp Lead Block from Container by Complementary Coatings Corp. Massachusetts General Law (MGL) c. 111, 189A-199B (the Lead Law) Regulations for Lead Poisoning Prevention and Control 105 CMR 460.000 FOR MORE INFORMATION OR PROBLEM RESOLUTION, CALL: Complementary Coatings Corp. at 1-800-225-5554 Childhood Lead Poisoning Prevention Program at 1-800-532-9571 or 781-774-6711 (out of state) The Licensed Deleader, who applied the encapsulant. If homeowner or agent applied product, you may wish to call a Licensed Deleader for advice or assistance. Rev 6-7/25/96, 9/29/98; Revised 11/22/2010

Commonwealth of Massachusetts - Department of Public Health Childhood Lead Poisoning Prevention Program (CLPPP) Donovan Health Bldg, 5 Randolph St, 1 st floor, Canton, MA 02021 ENCAPSULANT PRODUCT FACT SHEET Encapsulants are coatings applied in liquid form that are made to be long-lasting barriers over lead paint. Conventional paint is not an encapsulant. The Regulations for Lead Poisoning Prevention and Control require a lead inspection and a surface assessment be performed before encapsulants are applied. The Regulations allow encapsulants to be applied by a Licensed Deleading Contractor, a homeowner or a homeowner s agent. If a homeowner or his/her agent will be applying the encapsulant, they must first be authorized by CLPPP by reading a training booklet taking a quiz, and mailing or faxing the quiz to CLPPP (781.774. 6700). Contact CLPPP for more information at 1-800-532-9571 or www.mass.gov/dph/clppp The use of properly applied encapsulant products with the D/L Laboratories seal of approval can satisfy Massachusetts requirements for lead paint abatement. The product named on this Fact Sheet has Massachusetts approval for deleading. NAME: Insl-Cap Lead Encapsulating Compound REQUEST MSDS FROM: Complementary Coatings Corp. 101 Paragon Dr., Montvale, NJ 07645 / 800-225-5554 PRODUCT DESCRIPTION: DL-10019 Type: elastomeric-thermoplastic water-based copolymer Mixing: ready to use, mix thoroughly Finish: eggshell Colors: white Dry Time: 2 to 4 hrs (to touch) Tintable: Yes, contact manufacturer Dilutable: no Full Cure: 12 to 24 days Mixable with Another Product: no Paintable: yes Type of Cure: coalescence Sizes: 1, 5, US gallon containers Flash Point: none Disposal: in accordance with local, state and federal regulations VOC: 44 grams per liter Application Equipment: airless spray (best), brush, roller Clean-Up: soapy water Spreading Rate to Achieve Required 7 Mils Dry Film Thickness No. Coats Thickness Per Wet Coat Thickness Per Dry Coat Spreading Rate Per Wet Coat Brush or Roller 2 9 mils 3 to 5 mils 180 sq. ft./gal Airless Spray 1 18 mils 7 mils 90 sq. ft./gal Spreading Rate to Achieve Required Dry Film Thickness: 100 sq. ft/gal Note: Spreading rate does not include any loss during application process. RECOMMENDED USES: WALLS: walls, chair rails, baseboards DOORS: doors, casings WINDOWS: sills, aprons, casings CEILINGS: ceilings without calcimine STAIRS: risers, railing caps, handrails, balusters, newel posts, stringers OTHER: curved wooden surfaces CABINETS: nonfriction surfaces DRAWERS: nonfriction surfaces USES NOT RECOMMENDED: WALLS: walls with chalking or calcimine DOORS: door jambs WINDOWS: (see prohibited list) CEILINGS: ceilings with calcimine OTHER: working radiators, friction surfaces CABINETS: friction surfaces DRAWERS: friction surfaces PROHIBITED: floors, stair treads, thresholds, any exterior surface, as well as the sashes, parting beads, window wells, and the interior/exterior or header stops of moveable windows.

SURFACE PREPARATION: Massachusetts regulations require, and the manufacturer recommends, that a surface assessment, including an inspection and adhesion test (ASTM D3359), be performed on the surface to be coated before applying Insl-Cap Apply Insl-Cap to a clean, dry surface. Surfaces to be encapsulated must be free of all blistered, peeling or loose paint. Clean and remove grease, wax, oil, smoke residues, and other contaminants by washing with detergent and rinsing with plenty of clean water. Prime bare metal with Insl-X Checkrust Primer for Insl-Cap. Apply Insl-X PS-8000 PrimeLock Low VOC Primer to water stains or other discolored areas. ENCAPSULANT APPLICATION: Apply in multiple coats, if necessary, to achieve desired 7 mils dry film thickness. Airless spray, roller or brush may be used. OCCUPANCY DURING APPLICATION: Occupancy permitted in general area during brush or roller application, but not in interior space being encapsulated. For spray application, occupancy is prohibited during the time of application for worksite safety reasons only. Occupants may return when application is done. OCCUPANCY AFTER APPLICATION: Make sure adequate ventilation is available for the first 24 hours after application. CAUTIONS: Use with adequate ventilation. If respiratory irritation develops, increase ventilation or wear respiratory protection. Use NIOSH approved TC-21C-287 or equivalent during spray application. Avoid contact with eyes and skin. Wash hands after using. Wear impervious gloves and safety goggles or glasses for maximum protection. WARRANTY: Insl-Cap has limited product liability for 20 years. The purchaser shall notify Complementary Coatings Corp. or distributor where purchased to advise of any suspected manufacturing defects. CARE AND MAINTENANCE: Insl-Cap cannot prevent exposure to the encapsulated lead based paint if surface film is damaged, broken or abraded. Routine inspection for holes, cracks, dents, bubbles, peeling, or any other defect including water damage is important to maintain maximum efficiency of this coating. Damaged surfaces should be repaired and re-encapsulated immediately. REFERENCES: Deciding Whether to Encapsulate by Childhood Lead Poisoning Prevention Program Register of Approved Encapsulants by Childhood Lead Poisoning Prevention Program Care and Maintenance of Encapsulants by Childhood Lead Poisoning Prevention Program Material Safety Data Sheet (MSDS) for Insl-Cap Lead Encapsulating Compound by Complementary Coatings Corp. Insl-Cap Lead Encapsulating Compound Label from Container by Complementary Coatings Corp Massachusetts General Law (MGL) c. 111, 189A through 199B (the Lead Law) Regulations for Lead Poisoning Prevention and Control 105 CMR 460.000 FOR MORE INFORMATION OR PROBLEM RESOLUTION, CALL: Complementary Coatings Corp at (800) 225-5554 (or contact by fax at (888) 248-2143) Childhood Lead Poisoning Prevention Program at (617) 753-8400 or 1 (800) 532-9571 Licensed Deleader, if one applied encapsulant. If homeowner or agent applied product, you may wish to call a Licensed Deleader for advice or assistance rev 7/25/96 Revised 11/22/2010

Commonwealth of Massachusetts - Department of Public Health Childhood Lead Poisoning Prevention Program (CLPPP) Donovan Health Bldg, 1 st floor, Randolph at Canton, MA 02021 ENCAPSULANT PRODUCT FACT SHEET Encapsulants are coatings applied in liquid form that are made to be long-lasting barriers over lead paint. Conventional paint is not an encapsulant. The Regulations for Lead Poisoning Prevention and Control require a lead inspection and a surface assessment be performed before encapsulants are applied. The Regulations allow encapsulants to be applied by a Licensed Deleading Contractor, a homeowner or a homeowner s agent. If a homeowner or his/her agent will be applying the encapsulant, they must first be authorized by CLPPP by reading a training booklet taking a quiz, and mailing or faxing the quiz to CLPPP (781.774. 6700). Contact CLPPP for more information at 1-800-532-9571 or www.mass.gov/dph/clppp The use of properly applied encapsulant products with the D/L Laboratories seal of approval can satisfy Massachusetts requirements for lead paint abatement. The product named on this Fact Sheet has Massachusetts approval for deleading. NAME: Lead Stop Dumond Chemical REQUEST MSDS FROM: www.msds.com 101 Paragon Dr., Montvale, NJ 07645 / 800-225-5554 PRODUCT DESCRIPTION: DL-10019 Type: modified acrylic elastomeric resin Mixing: ready to use, mix thoroughly Finish: eggshell Color(s): decorator white, colors Dry Time: 4-12 hrs (to touch) Tintable: yes - contact manufacturer Dilutable: no Full Cure: 14 days Mixable with Other Products: no Paintable: yes (with alkyd or latex enamel) Type of Cure: coalescence/crosslinking Sizes: 1 and 5 U.S. gallon containers Flash Point: none Disposal: same as latex paint (follow local ordinances) VOC: < 100 grams per liter Application Equipment: airless spray (best), brush, roller Clean-Up: warm, soapy water Spreading Rate to Achieve Required 14-16 Mils Dry Film Thickness Premier Coatings, Inc. No.Coats Thickness Per Wet Coat Thickness Per Dry Coat Spreading Rate Per Wet Coat Brush or Roller 3-4 8-10 mils 4-5 mils 200 sq.ft./gal Airless Spray 2 14-16 mils 7-8 mils 100 sq.ft./gal Spreading Rate to Achieve Required Dry Film Thickness - 50 sq.ft./gal Note: Spreading rate does not include any loss during application process. RECOMMENDED USES: WALLS: walls, chair rails, baseboards DOORS: doors, casings WINDOWS: aprons, casings CEILINGS: ceilings without calcimine STAIRS: balusters, newel posts, stringers. Topcoat of alkyd or latex enamel required for railing caps, handrails OTHER: curved wooden surfaces, nonworking radiators CABINETS: nonfriction surfaces, topcoat of alkyd or latex enamel required DRAWERS: nonfriction surfaces, topcoat of alkyd or latex enamel required USES NOT RECOMMENDED: WALLS: walls with chalking or calcimine DOORS: jambs WINDOWS: (see prohibited list) CEILINGS: ceilings with calcimine OTHER: working radiators, friction surfaces CABINETS: friction surfaces DRAWERS: friction surfaces PROHIBITED: floors, stair treads, thresholds, any exterior surface, as well as the sashes, parting beads, window wells, and the interior/exterior or header stops of moveable windows.

SURFACE PREPARATION: Comply fully with product specifications. All surfaces must be clean, sound, dry and free of dust, rust, grease, oil, mildew and loose particles before application. A licensed deleader must remove all flaking and peeling paint down to a sound surface. Repair damage with a joint compound and smooth over with a damp sponge to remove excess compound and blend into surrounding wall surface. Remove all oil, grease, wax, smoke residues and other contaminants by washing with a suitable cleaner and rinsing with clean water. Remove mildew by washing with a solution of TSP (tri-sodium phosphate) in one gallon of water and add one quart of commercial bleach. Wear gloves and protective eye wear if using bleach solutions. For high-gloss surfaces, wet scour with TSP or a strong detergent substitute and water solution using coarse steel wool to eliminate any gloss. Thoroughly remove by washing any residual scouring material, detergent or other surface preparation material, and dry completely prior to application. Although no special primers are required, there may be occasions where a primer would be beneficial in the overall performance of the coating: prime water stains with stain blocking primer; prime chalking with penetrating chalk primer; prime bare wood with an enamel undercoater; prime drywall with a quality acrylic primer and sealer. ENCAPSULANT APPLICATION: Apply in multiple coats. Achieve total thickness of 32-36 mils (wet), but do not exceed 36 mils. Use wet mil gauge when applying product. Do not apply if ambient temperature is below 45 F. Airless spray application in two coats (each 14-16 mils) is recommended for best results, including a smoother dry film. Use.017 to.019 inch orifice and a 60 mesh screen. If applied with a brush or roller, multiple coats are required to achieve required thickness. Expect 6-8 wet mils/coat by brush and 8-12 wet mils/coat by roller. Use a polyester or polyester/nylon brush. Use a high quality tapered trim brush with a filament density to achieve a smooth finish on all trim work. Application to a large smooth or any size rough area should be performed with a quality roller cover with a 1/2 to 3/4 inch nap. Regular paint topcoats may be applied over surfaces that have been sprayed, rolled or brushed with Lead Stop OCCUPANCY DURING APPLICATION: Occupancy is permitted during brush or roller application, but not in room or interior area being encapsulated. For spray application, occupancy is prohibited during the day for worksite safety reasons only. Occupants may return at the end of the workday. OCCUPANCY AFTER APPLICATION: Yes. Use adequate ventilation for first 24 hours after application. CAUTIONS: Use with adequate ventilation. If respiratory irritation develops, increase ventilation or wear respiratory protection. Use molded polymesh shell dust and mist respirator - MSHA, NIOSH Approval No. TC-21C-287 or equivalent - during spray application. Avoid contact with eyes and skin. Wash hands thoroughly with soap and water after using. During application wear gloves and safety goggles. WARRANTY: Lead Stop has limited product liability for 20 years. The purchaser shall notify Dumond Chemical within 30 days after any damage arising out of any defect in manufacturing. CARE AND MAINTENANCE: Lead Stop will not protect occupants from ingestion of the encapsulated lead-based paint if surface is damaged, broken, or abraded. Surfaces coated with Lead Stop must be inspected routinely for holes, cracks, dents, peeling surfaces, bubbles, and any other defect, including water damage. Damaged surfaces should be repaired and re-encapsulated immediately to prevent exposure to the lead hazard. REFERENCES: Deciding Whether to Encapsulate by Childhood Lead Poisoning Prevention Program Register of Approved Encapsulants by Childhood Lead Poisoning Prevention Program Care and Maintenance of Encapsulants by Childhood Lead Poisoning Prevention Program Material Safety Data Sheet (MSDS) for Lead Block by Complementary Coatings Corp Lead Stop from Container by Complementary Coatings Corp. Massachusetts General Law (MGL) c. 111, 189A-199B (the Lead Law) Regulations for Lead Poisoning Prevention and Control 105 CMR 460.000 FOR MORE INFORMATION OR PROBLEM RESOLUTION, CALL: Complementary Coatings Corp. at 1-800-225-5554 Childhood Lead Poisoning Prevention Program at 1-800-532-9571 or 781-774-6711 (out of state) The Licensed Deleader, who applied the encapsulant. If homeowner or agent applied product, you may wish to call a Licensed Deleader for advice or assistance. Rev 6-7/25/96, 9/29/98 Revised 11/22/2010

Commonwealth of Massachusetts - Department of Public Health Childhood Lead Poisoning Prevention Program (CLPPP) Donovan Health Bldg, 1 st flr. Randolph at Canton, MA 02021 ENCAPSULANT PRODUCT FACT SHEET Encapsulants are coatings applied in liquid form that are made to be long-lasting barriers over lead paint. Conventional paint is not an encapsulant. The Regulations for lead poisoning prevention require a lead inspection and a surface assessment be performed before encapsulants are applied. The Regulations allow encapsulants to be applied by a Licensed Deleading Contractor, a homeowner or a homeowner s agent. If a homeowner or his/her agent will be applying the encapsulant, they must first be authorized by CLPPP by reading a training booklet taking a quiz, and mailing or faxing the quiz to CLPPP (781.774. 6700). Contact CLPPP for more information at 1-800-532-9571 or www.mass.gov/dph/clppp The use of properly applied encapsulant products with the D/L Laboratories seal of approval can satisfy Massachusetts requirements for lead paint abatement. The product named on this Fact Sheet has Massachusetts approval for deleading. NAME: LBC Lead Barrier Type I REQUEST MSDS FROM: www.msds.com Fiberlock Technologies, Inc. 150 Dascomb Road, Andover, MA 01810 PRODUCT DESCRIPTION: DL-9977 Type: elastomeric-thermoplastic water-based copolymer Mixing: ready to use, mix thoroughly Finish: eggshell Color(s): antique linen Dry Time: 2-4 hrs (to touch) Tintable: no - contact manufacturer Dilutable: no Full Cure: 12-24 days Mixable with Another Product: no Paintable: yes Type of Cure: coalescence Sizes: 1, 5, 55 U.S. gallon containers Flash Point: none Disposal: in accordance with local, state and federal regulations VOC: 209 grams per liter Application Equipment: airless spray (best), brush, roller Clean-Up: warm, soapy water Spreading Rate to Achieve Required 7 Mils Dry Film Thickness No.Coats Thickness Per Wet Coat Thickness Per Dry Coat Spreading Rate Per Wet Coat Brush or Roller 2 7-8 mils 3-4 mils 240 sq.ft./gal Airless Spray 1 17 mils 7-8 mils 120 sq.ft./gal Spreading Rate to Achieve Required Dry Film Thickness - 120 sq.ft./gal Note: Spreading rate does not include any loss during application process. RECOMMENDED USES: WALLS: walls, chair rails, baseboards DOORS: doors, casings WINDOWS: sills, aprons, casings CEILINGS: ceilings without calcimine STAIRS: risers, railing caps, handrails, balusters, newel posts, stringers OTHER: curved wooden surfaces CABINETS: nonfriction surfaces DRAWERS: nonfriction surfaces USES NOT RECOMMENDED: WALLS: walls with chalking or calcimine DOORS: door jambs WINDOWS: (see prohibited list) CEILINGS: ceilings with calcimine OTHER: working radiators, friction surfaces CABINETS: friction surfaces DRAWERS: friction surfaces PROHIBITED: floors, stair treads, thresholds, any exterior surface, as well as the sashes, parting beads, window wells, and the interior/exterior or header stops of moveable windows.

SURFACE PREPARATION: Prior to application of LBC Lead Barrier Compound Type I, inspect all surfaces to insure that they are clean, dry and free of all foreign matter including dust, rust, grease, oil, mildew, glue size, calcimine, wax, soap, loose paint, etc. Patch and repair irregularities in surfaces with prepared vinyl patch or appropriate patching compound. Use Fiberlock Technologies, Inc. Power Block or any other stain-blocking primer for surfaces which have been water-damaged or discolored. For high-gloss or newly painted surfaces, wet scour with a strong detergent or surface preparation treatment, using a course scouring pad to eliminate any gloss. Thoroughly remove by washing any residual scouring material, detergent or other surface preparation material, and dry completely prior to application. Wear gloves and protective eye wear if using caustics. ENCAPSULANT APPLICATION: Apply with airless spray equipment for best results. Adjust G.P.M. and P.S.I. setting and tip size according to the production and control requirements of the job and the skill of the applicator. Smaller pumps using smaller tips at higher P.S.I. settings are better suited for jobs requiring higher accuracy and greater control. Larger pumps using larger tips at lower P.S.I. settings produce higher production application for large, open jobs, but require a higher level of application skill. Apply by brush or roller at 200 sq ft/gal for 7-8 mils (wet) and 3-4 mils (dry) per coat. Apply liberally and uniformly with a polyester or polyester/nylon brush to woodwork and trim. Use a wet mil gauge to control thickness. Multiple coats may be necessary to achieve required 7 mils dry thickness. Allow each coat to dry before applying additional coats. Use a trim brush to achieve a smooth finish on trim work. OCCUPANCY DURING APPLICATION: Occupancy is permitted during brush or roller application, but not in room or interior space being encapsulated. For spray application, occupancy is prohibited during the day for for worksite safety reasons. Occupants may return at the end of the workday. OCCUPANCY AFTER APPLICATION: Yes. Use adequate ventilation for first 24 hours after application. CAUTIONS: Use with adequate ventilation. If respiratory irritation develops, increase ventilation or wear respiratory protection. Use molded polymesh shell dust and mist respirator - MSHA, NIOSH Approval No. TC-21C-287 or equivalent - during spray application. Avoid contact with eyes and skin. Wash hands thoroughly with soap and water after using. During application, wear gloves and safety glasses or goggles. WARRANTY: LBC Lead Barrier Compound Type I has a 20-year minimum warranty with certain limitations. (See product label.) Notify Fiberlock Technologies, Inc. within 45 days of purchase to advise of any suspected manufacturing defects. CARE AND MAINTENANCE: LBC Lead Barrier Compound Type I will not prevent exposure to the encapsulated lead-based paint if surface is damaged, broken or abraded. Surfaces coated with L-B-C Lead Barrier Compound Type I must be inspected routinely for holes, cracks, dents, peeling surfaces, bubbles, and any other defect, including water damage. Damaged surfaces should be repaired and reencapsulated immediately to prevent exposure to the lead hazard. REFERENCES: Deciding Whether to Encapsulate by Childhood Lead Poisoning Prevention Program Register of Approved Encapsulants by Childhood Lead Poisoning Prevention Program Care and Maintenance of Encapsulants by Childhood Lead Poisoning Prevention Program Material Safety Data Sheet (MSDS) for LBC Lead Barrier Compound Type I by Fiberlock Technologies, Inc. LBC Lead Barrier Compound Label from Container by Fiberlock Technologies, Inc. Massachusetts General Law (MGL) c. 111, Sect. 189A-199B (the Lead Law) Regulations for Lead Poisoning Prevention and Control (105 CMR 460.000) FOR MORE INFORMATION OR PROBLEM RESOLUTION, CALL: Fiberlock Technologies, Inc. at 800-342-3755 or 978.623.9987 Childhood Lead Poisoning Prevention Program at 1-800-532-9571 or 781-774-6711 (out of state) The Licensed Deleader, who applied the encapsulant. If homeowner or agent applied product, you may wish to call a Licensed Deleader for advice or assistance. Rev 7/25/96; Revised 11/22/2010