NETWORK ENABLED EQUIPMENT MONITOR



Similar documents
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

Temperature & Humidity SMS Alert Controller

Simplify Data Acquisition with a Built-in LXI Web Server

USB-500/600 Series Low-Cost Data Loggers and Accessories

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

NetScanner System. Toronto: , Montreal: , Toll Free: ,

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: Version 1.0

USB-500 Series Stand-Alone, Low-Cost Data Loggers

USB-500 Series Low-Cost Data Loggers and Accessories

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

1.44 kw Programmable DC Power Supplies XLN Series

The Universal DAQ Device. Connect and measure immediately!

NAFEM Gateway User s Manual For Watlow part numbers NGW , NGW , NGWC , NGWC

NEW. EVEN MORE data acquisition and test stand automation

O C M III. Open Channel Flow Monitor

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

Current Monitoring Kit QUICK START GUIDE

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

NortechCommander Software Operating Manual MAN R6

Current Monitoring Kit

PowerCommand iwatch 100

vyacht Wifi Router vyacht yacht automation About this manual

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

GV-Data Capture V3 Series User's Manual

EVAL-UFDC-1/UFDC-1M-16

CMS Central Monitoring System

GE Security. FHSD Monitor / Web Server user manual

High Power Programmable DC Power Supplies PVS Series

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

WISE-4000 Series. WISE IoT Wireless I/O Modules

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

ECONseries Low Cost USB DAQ

PLC GPRS NET Data Logger

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

TX2123 RS485 TO ETHERNET ADAPTOR

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Wireless Router Setup Manual

I2C PRESSURE MONITORING THROUGH USB PROTOCOL.

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

3.5 EXTERNAL NETWORK HDD. User s Manual

Application/Connection Examples

Product Description. Model VM 500 series [ VM508/VM508E ] Water Alarm. Telephone/Pager Alert Calls. Power Alarm. Maximum Number of Sensors

BiPAC 7404V series. VoIP/(802.11g) ADSL2+ (VPN) Firewall Router. Quick Start Guide

Technical Information POWER PLANT CONTROLLER

WIRELESS INSTRUMENTATION TECHNOLOGY

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Fax Server. Fax Server PRI. Blue Line. Fax Server for ISDN30 line bundles

Temperature Alert. LAN-based Temperature and Humidity Data Logger

ORION TELECOM NETWORKS INC. T1

How To Set Up An Andsl Modem Router For Internet Access

DCS Series 1 kw, 1.2 kw, & 3 kw

Data Loggers for Real Time Temperature Monitoring - WiFi

M2M I/O Modules. To view all of Advantech s M2M I/O Modules, please visit

Access control designed simply for you

MH - Gesellschaft für Hardware/Software mbh

GPS NTP Time Server for Intranet Networks DIN RAIL Version

Application Note: Monitoring Branch Circuit Loads in Critical Facilities

Tracer Summit Web Server

Starting a Management Session

SNMP Web Management. User s Manual For SNMP Web Card/Box

Disturbance Recoder SPCR 8C27. Product Guide

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

USB-500/600 Series Low-Cost Data Loggers and Accessories

Gigabyte Content Management System Console User s Guide. Version: 0.1

SecureLinx Spider Duo Quick Start Guide

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

Medical Vacuum Systems-PXMI

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Energy Storage System Performance Testing

Web-Based Remote Monitoring & Datalogging

Innovative Electronics for a Changing World INDEX

sat-nms SMU Signal Management Unit

Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)

Olson Electronics Remote Power Monitoring Meter

Radiological Assessment Display and Control System

User Manual. EtherUSB

Orbit PCI Mk 2 Network Card. User Manual. Part No Issue 4

Measuring Temperature withthermistors a Tutorial David Potter

F453. TiF453. User guide 10/11-01 PC

Rosemount Analytical s X-STREAM XE Web-Browser Interface Takes Process Analysis to the Next Level

Unidirectional Transmitter/ Receiver Units Introduction

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

USB-AD16f Data acquisition system (USB)

Table of Contents. Chapter1. Introduction Before Installation System Requirements... 1

WiFi Edition

Waveguide Access Point WGA631. Product Guide

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Zoom Network camera, PoE 802.3af, IR LEDs, 2-Megapixel, Day & Night, Outdoor

H.264 Internet Video Server

Internet-bridge XPort

Products Range Overview. Products Range Overview. The ZigBee Plug & Play wireless Network for Building and Industrial Applications

USING THE XPERT2 / 9210B ON A TCP/IP NETWORK

Ovation Operator Workstation for Microsoft Windows Operating System Data Sheet

Cryogenic Temperature Monitors Model 12 and Model 14 Two or four input channels with Ethernet connectivity

Electronic Control Devices The European Product Catalogue 2007

Transcription:

NETWORK ENABLED EQUIPMENT MONITOR Remotely Monitor Sensors over the Internet Connect Sensors to the Web to Remotely Monitor Equipment, Processes or Other Applications A Complete, Easy to Deploy, Stand-Alone Solution Compatible with Many Different Types of Sensors and Other Signal Generating Devices Low Cost Monitor is Independent of Existing Equipment Control Electronics, Does Not Require a Dedicated Data Acquisition PC, & Does Not Require Any Subscriptions Quick Set-Up, Virtually No Learning Curve - Just Follow the Screen Prompts - within 30 Minute View Your Data on the Internet with your Browser 112 Product Description The Sensor Synergy Network Enabled Equipment Monitor (NEEM) brings simplicity and affordability to remote sensor monitoring. It continuously measures sensors connected to the target equipment and records this information for later web-browser or Data Logger viewing. The measured and stored data can be viewed by an Internet connected web browser as either a continuously updated, live data Web page or as a review of past equipment performance. Past measurements are displayed in a tabular or graphical form and can review data from virtually any time period during prior year. Depending on the user s needs and the user s network resources, the NEEM can deliver data to a single connected computer, a local area network only, or to the Internet. 1110 W. Lake Cook Rd. Suite #340 Buffalo Grove, IL 60089 847 353-8200 FAX 847 353-8232 www.sensorsynergy.com

Network Enabled Equipment Monitor Equipment or Process to be Monitored Sensor Interface & Data Acquisition Tools A Complete Solution The network-connected user only needs to start their standard, off-the-shelf web browser or the supplied open-source Data Logger program and enter the IP address previously entered into the NEEM unit during configuration. If the password feature is enabled during the NEEM set-up, the network-based user will need to enter the password and then select which web data page they would like to view. Internet NEEM MicroWeb Server Send HTML & Java Applets to Client Computers Connected to NEEM IP Address Sensor Monitor Module Scheduler, Data Processing, Configuration Tools, Percent Utilization Calculator Data Storage & Retrieval Sensor/Actuator Engine IEEE-1451.2 Electronic Data Sheet, Smart Transducer Interface Module, & Transducer Interface Electronics No additional hardware or software is required to view the status of your equipment. No monthly subscriptions of any kind are required. The entire configuration and set-up process generally requires less than 30 minutes from opening the shipping carton to viewing data from the network. NEEM arrives with support for nine types of sensors including sensor that generate the following types of signals: 0-to-5 volt single ended analog signal +/- 10 volt single ended analog signals +/- 2.5 volt differential analog signals 4-20 ma analog current signals digital voltage signals at 5 volts or ground switch closure signals 0-to-5 volts pulses in which the measured quantity is related to the number of pulses per second, Type K Thermocouple Internal Temperature Sensor monitors and reports the temperature of the NEEM unit s environment internal enclosure temperature. During the NEEM-112 unit configuration, the user selects a primary sensor channel. Sensor data acquired from the primary sensor channel will be sampled every 20 seconds and stored for 1-year. The user gets to select 4 primary sensors channels for the NEEM-115. All sensor channels include an optional threshold and comparison operator. The comparison operator allows the user to which type of sensor signal will be used to indicate the utilization status of the equipment to be monitored. The user then sets the threshold value so that all sensor measurements above the threshold contribute to the in-use condition. All sensor measurements below the threshold contribute to the not-in-use condition. The NEEM can be viewed as a miniature data acquisition system with an integrated micro-web server. NEEM provides the data acquisition, data interpretation, and display customization for the specific equipment being monitored. The micro-web server is pre-loaded with software to deliver and display live Web pages with real time data updates. This software can also be used to review previously recorded data. NEEM utilizes Electronic Data Sheets that contain configuration, calibration and identification information about each connected sensor. The NEEM unit is compatible with a subset of the IEEE 1451.2 transducer interface standard and utilizes the standard s command set, transducer electronic data sheet (TEDS), and data formats. NEEM is able to convert many types of standard analog data signals into digital information, which is then formatted and included in Web-page displays. These live-data Web pages are served by a micro- Web server contained within the Network Enabled Equipment Monitor unit. The data is formatted in a graphical form or a tabular form for display on most popular web browser programs as shown below. The same programs used to surf-the-net can be used to view data from sensors, or to control actuators with special optional features installed. Sensor Synergy, Inc 1110 W. Lake Cook Rd. Suite #340 Buffalo Grove, IL 60089 847 353-8200 FAX 847 353-8232 www.sensorsynergy.com - 2 -

All of these features are included within the standard NEEM product, in the 6.8 (172mm) x 8.2 (208) x 2.3 (58mm) enclosure. Sensor Input Specifications 0 to 5 Volt Single Ended Input High Accuracy, 12-Bit Successive Approximation Register type Analog-to-Digital Converter 1.2 millivolt measurement resolution (Optional - Up to 4 Single-Ended Inputs Input Impedance >10 MO Input Offset Voltage less than 1.0 millivolt Typical Input Current < 1.0 na In addition, a separate data-logging program is provided that will run on remote, network-connected computers and can be used for long-term collection and storage of data on local hard drives. 4 to 20 ma Current Loop Receiver Measurement Resolution 5uA Optically Isolated Interface Inputs Isolated with UL1577 Recognized components (5KV rms/1 min) Compliant with input signals driven by voltage levels from 9 to 50 volts Event Counter Minimum Counting Interval Configurable from 0.001 seconds Maximum Count Rate 50,000 events/second Timing Calibration Accuracy +/- 0.005% Maximum Count Value in Excess of 4 billion Standard CMOS logic level inputs o Logic Low Input less than 0.8 volts Logic High Input greater than 2.4 volts o Maximum 5 volt input The NEEM unit is configured and the data display format is selected when the unit is installed at the site of the user s sensor. A network connection must be provided by the user via a standard 10-base-T, RJ-45 connection. If the network connection has a gateway to the Internet and the user elects to share the gateway information with the NEEM unit, then the connected sensor s analog information and equipment percent utilization data will be available to all Internet users empowered with the correct password and IP address. Thermocouple Measurements Includes Type K (Chromel-Alumel) Thermocouple Input Standard for User Supplied Type K Thermocouple Probes 1 o C Measurement Resolution for measurements greater than 40 o C Approximately 2 o C Measurement Accuracy o Absolute Measurement Accuracy Limits Due to Errors that Depend on the Composition Variations in User Supplied Type K Thermocouple Probe -Typically greater of 2.2 o C or 0.75% for measurements above 0 o C Measurements over Entire Useful Range of Type K Thermocouple Measure Temperatures Below -200 o C to Greater than +1200 o C o Actual Upper and Lower Measurement Limit Will Depend on the Construction Details of the User Supplied Type K Thermocouple Universal Type K Thermocouple Connector o Combination Standard/Miniature Type K Front Panel Connector Sensor Synergy, Inc 1110 W. Lake Cook Rd. Suite #340 Buffalo Grove, IL 60089 847 353-8200 FAX 847 353-8232 www.sensorsynergy.com - 3 -

Other types of thermocouples (J & E) available upon request On-Board Real Time Clock Real Time Clock Information Available including Year, Month, Day, Date, Hours, Minutes, Seconds Battery Back-Up for Clock, Nominal Battery Lifetime Exceeds 10 years Typical Accuracy +/- 2 seconds/day Optional Sensor/Actuator Features Analog Actuator/Control Signal Output (Optional) 2 Digital-to-Analog Converter (DAC) Channels 0 to 5 volts buffered output, 1.2 mv increments Source or Sink greater than 10 ma Digital Input/Output Signal Interface (Optional) 8 Digital Input/Output Signals Available Programmable, 8-Bit Parallel Interface Digital Input High > 2.4 volts referenced to NEEM Ground Digital Input Low < 0.8 Volts referenced to NEEM Ground Digital Input Current < 250 microamps Optical Isolation for Digital Inputs Available on Request Data Display Features Data from sensors attached to the NEEM unit is available through network connected client computers. The term client computer refers to a PC, a workstation, or other computer connected to a network and capable of receiving information from a server. If the NEEM is connected to a 10 Base-T Ethernet type Local Area Network (LAN) that is also connected to an Internet gateway, then the client computer can access sensor data through any Internet connection. If the NEEM unit is connected to a LAN that is not connected to the Internet, then the client computer must be connected to the same LAN as the NEEM for the client computer to access the transducer data. The micro-web server included with the NEEM unit serves HTML formatted files to attached client computers. The resulting live data screens use HTML assisted by Java applets to display sensor and actuator data in graphical or tabular form. Both the HTML and Java applets reside on the micro-web server and are included with the NEEM product. The client computer can use standard Web browsers (such as Microsoft s Internet Explorer and Netscape s Navigator) to display live data from sensors attached to the NEEM. The Client computer can also use other programs to request and receive sensor data through the TCP/IP stack with HTTP or Telnet protocols. Connectors RJ-45 10Base T Ethernet Connector 9-pin D-type Subminiature Connector to connect to a Serial (RS-232) port on a Windows PC (cable included with NEEM unit) 16-Connection, Pluggable, Screw-type Terminal Block Two-Tiers of 8 contacts to connect Sensor Signal Wires to NEEM Type-K Thermocouple Universal Connector for Standard and Miniature Male Thermocouple Connectors Support for other types of thermocouples is available as an option 10-Connection, Pluggable, Screw-type Terminal Block Two-Tiers of 8 contacts to connect Auxiliary Digital Signal Wires to NEEM Power Supply Connection - 2.1mm power jack matched to included power supply output connector. Data Storage in NEEM Several different types of information are captured and stored within the Network Enabled Equipment Monitor unit. The stored data includes the raw sensor data, the average sensor data during a 15-minute period, the utilization data for a 15- minute period, and the utilization data averaged for the day. The NEEM model number and selection table can be used to determine the number of sensors supported and the length of time that the data is stored. The current family of NEEM products store different types of data for different lengths of time from 2-days to 10 years. Archival Storage of Sensor Data 112 115 120 # of Sensors 1 4 6 Daily Equipment In-Use (Percentage) 10 years 10 years 10 years Average Equipment In-Use (Percentage Determined on 15 minute period) 4 years 4 years 6 years Average Sensor Data (Value for 15 minute interval) Detailed Sensor Data (Measurement every 20 seconds) 4 years 4 years 6 years 1 year 6 months for 4 sensors or 1 year for 2 sensors 8 months Including the sensor used to indicate the in-use condition, from 1 to 6 sensors are supported by different models in the NEEM family. Other Power Supply Requirements Included AC Adapter provides NEEM unit with required 1 amp at 7 Volts DC AC Adapter uses 115 230 Volts to supply the NEEM unit. UL Listed AC Adapter Sensor Synergy, Inc 1110 W. Lake Cook Rd. Suite #340 Buffalo Grove, IL 60089 847 353-8200 FAX 847 353-8232 www.sensorsynergy.com - 4 -

NEEM Recommended Operating Temperature Range 0 o C to + 70 o C Enclosure Standard NEEM product is available in a 6.8 (172mm) x 8.2 (208mm) x 2.3 (58mm) enclosure. Extruded Aluminum Enclosure with an anodized finish NEEM Open Source Data Logger Included with the NEEM-112 is the source code and an executable form of the Open Source Data Logger program. This program, written in Microsoft Visual Basic 6 includes a wealth of features. This program will allow users to remotely log data to on-screen tables and charts and also provides users the capabilities to store NEEM-112 acquired data in hard disk files from any of the available NEEM-112 sensor channels. About Sensor Synergy Inc. Sensor Synergy develops complete solutions for interfacing sensors to networks using smart technologies. Established in 1999, Sensor Synergy combines interface electronics, networking, and software technologies with recent IEEE/NIST standards to innovate solutions for smart transducer interfaces. The company specializes in smart transducer interface products that include complete solutions to putting sensor data and actuator controls on the Internet in a userfriendly small package at a cost-effective price. The Sensor Synergy staff includes several experienced professionals with continuous involvement in standard setting bodies (IEEE) as well as participate in various technical conferences related to sensor and sensor interface topics. During the past 4 years Sensor Synergy professionals have chaired technical sessions on sensor interface technologies. Additional Information This program also includes alert capabilities that will launch windows messages, play sound files, or launch e-mail messages when an alert condition has occurred. NEEM Software Development Kit Included with the NEEM-112 is a software development kit that contains an Active X Control and documentation. These utility programs and manuals will allow software programmers to embed NEEM-112 data directly into other, Active-X compatible software applications. This includes the Microsoft Office suite programs Excel, Word, PowerPoint, Access and other programs that allow the use of Active-X controls. Many programs written in Microsoft programming languages are compatible with Active-X Controls including applications written in Visual C++, Visual Basic 6, Visual Basic Net, Visual C#, and many other languages. For additional information about the use of this product, contact Sensor Synergy via phone: 847-353-8200, FAX: 847-353-8232 or e-mail a request for information to info@sensorsynergy.com. Sensor Synergy, Inc assumes no responsibility for any errors, which may appear in this document and reserves the right to make changes to our products or this document at any time without prior notice. Sensor Synergy is a registered trademark of Sensor Synergy, Inc. This product is not authorized for use as a critical component or sub-system in life support systems. Copyright 2002-2004 Sensor Synergy, Inc. Sensor Synergy, Inc 1110 W. Lake Cook Rd. Suite #340 Buffalo Grove, IL 60089 847 353-8200 FAX 847 353-8232 www.sensorsynergy.com - 5 -