Redundancy in Adroit. Figure 1: Three level redundancy in Adroit. Client Workstations. Graphics Servers. I/O Servers.



Similar documents
FactoryTalk View Site Edition V5.0 (CPR9) Server Redundancy Guidelines

High Availability Essentials

DATAWORX32 V9.2 REDUNDANCY. An ICONICS Whitepaper

Industry White Paper. Ensuring system availability in RSView Supervisory Edition applications

White Paper ClearSCADA Architecture

14 Failover and Instant Failover

Support Guide: Managing the Subject machine s Firewall.

DataWorX32 Professional Getting Started with Redundancy

Web based training for field technicians can be arranged by calling These Documents are required for a successful install:

Network Load Balancing

Remote Desktop Services Overview. Prerequisites. Additional References

NetSpective Global Proxy Configuration Guide

Kepware Technologies KEPServerEX Client Connectivity Guide for GE's Proficy ifix

Home Station ADSL. You may also use the following address (regardless of whether you have changed the primary address or not):

Astaro Deployment Guide High Availability Options Clustering and Hot Standby

Microsoft Lync 2010 Deployment Guide

Multiple Public IPs (virtual service IPs) are supported either to cover multiple network segments or to increase network performance.

How To Connect To An Egrabit With A Vpn On A Pc Or Mac Or Ipad (For Pc Or Ipa) With A Pv (For Mac) Or Ipv (Femalese) With An Ipv Or Ip

Getting Started with Endurance FTvirtual Server

pcanywhere Advanced Configuration Guide

1 Installation. Note: In Windows operating systems, you must be logged in with administrator rights to install the printer driver.

Virtual SAN Design and Deployment Guide

Simple Software for a Business Continuity Plan and a Disaster Recovery Plan (BCP DRP) pdf ppt

Visualization SIMATIC. Visualization. Present sample project. HMI configuration. Insert HMI device from libraries 3. Configuring HMI connection 4

Vijeo Citect Architecture and Redundancy Study Guide

WhatsUp Event Alarm v10.x Listener Console User Guide

Getting started. Creating a Web Server support application

AP6511 First Time Configuration Procedure

Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)

White Paper. ThinRDP Load Balancing

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

Configuring the BIG-IP and Check Point VPN-1 /FireWall-1

Pulse Redundancy. User Guide

Software for Agilent Technologies Vector Series Network Analyzers

Overview of WebMux Load Balancer and Live Communications Server 2005

Administrator Guide VMware vcenter Server Heartbeat 6.3 Update 1

Introduction. What is a Remote Console? What is the Server Service? A Remote Control Enabled (RCE) Console

SyncLockStatus Evaluator s Guide

Option nv, Gaston Geenslaan 14, B-3001 Leuven Tel Fax Page 1 of 14

Beckhoff TwinCAT. Configuring the TwinCAT I/O System

SIMATIC. WinCC V7.0. Getting started. Getting started. Welcome 2. Icons 3. Creating a project 4. Configure communication 5

IntraVUE Plug Scanner/Recorder Installation and Start-Up

Where can I install GFI EventsManager on my network?

WHAT IS SCADA? A. Daneels, CERN, Geneva, Switzerland W.Salter, CERN, Geneva, Switzerland. Abstract 2 ARCHITECTURE. 2.1 Hardware Architecture

Expert Reference Series of White Papers. Planning for the Redeployment of Technical Personnel in the Modern Data Center

Evaluation of Dell PowerEdge VRTX Shared PERC8 in Failover Scenario

Guideline for setting up a functional VPN

WinCC. Configuration Manual. Manual Volume 3

Application Note 116: Gauntlet System High Availability Using Replication

Configuration Notes 0215

Configuring Health Monitoring Using Health Probes

EZ RMC Remote HMI App Application Guide for ios

SOFTWARE MANUAL UNIOPC

Application Note Connect to a Rockwell PLC over Netbiter Remote Access

Deploying Windows Streaming Media Servers NLB Cluster and metasan

Cisco Active Network Abstraction Gateway High Availability Solution

Copyright 2013 EMC Corporation. All Rights Reserved.

1. Central Monitoring System Software

Remote Application Server Version 14. Last updated:

WW HMI SCADA-08 Remote Desktop Services Best Practices

How to install and use CrossTec Remote Control or SchoolVue in a Virtual and or Terminal Service environment

DSX-HSCS Hot Swap Comm Server

LabTech Remote Tray. Overview. Accessing the Tray. LabTech

Redundancy for OPC. by Robert McIlvride and Andew Thomas Cogent Real-Time Systems Inc.

Step-by-Step Setup Guide Wireless File Transmitter

Syslog Server Configuration on Wireless LAN Controllers (WLCs)

DB2 Connect for NT and the Microsoft Windows NT Load Balancing Service

Step-by-Step Setup Guide Wireless File Transmitter FTP Mode

How to Create a Virtual Switch in VMware ESXi

Remote Application Server Version 14. Last updated:

Load-Balanced Merak Mail Server

NetSpective Logon Agent Guide for NetAuditor

Victoria Combo Remote Control

Step-by-Step Setup Guide Wireless File Transmitter

1Z Oracle Weblogic Server 11g: System Administration I. Version: Demo. Page <<1/7>>

T101 - Migrating your HMI System

FactoryTalk Gateway Getting Results Guide

Installing IDEA v8 Client Software on Citrix Server Environment

Oracle Exam 1z0-102 Oracle Weblogic Server 11g: System Administration I Version: 9.0 [ Total Questions: 111 ]

Network DK2 DESkey Installation Guide

Kramer Electronics, Ltd. Site-CTRL and Web Access Online User Guide (Documentation Revision 2)

Implementing Storage Concentrator FailOver Clusters

DIGIMobile V2 User Manual

Setting up RDP on your ipad

APPENDIX 8 EAZY NETWORKING

User Guide. Version R91. English

EZ RMC Remote HMI App Application Guide for Android Devices

C-more Remote Access, Data Log, FTP File Transfer, and Tutorial

Server Installation Manual 4.4.1

Implementing and using the NetSupport Connectivity Server

1. Central Monitoring System Software

Network Client. Troubleshooting Guide FREQUENTLY ASKED QUESTIONS

PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.

Chapter 4 Control Center

SURF Feed Connection Guide

Using Remote Web Workplace Version 1.01

GPS Tracking Solution GPS GSM Tracker

Cisco Application Networking Manager Version 2.0

Configuring Virtual Switches for Use with PVS. February 7, 2014 (Revision 1)

Transcription:

Redundancy in Adroit Very few SCADA HMI products offer genuine, true redundancy whereby operational integrity of the engineered solution can survive hardware failure in one of the system components. And those that do, require complex script programming and system engineering to achieve the requirement of a highlyavailable, resilient solution. One of Adroit s major features that translate directly into a key benefit for endusers and system integrators alike, is the ability to implement redundancy by simple point-and-click configuration at the time a solution is being engineered. Redundancy in Adroit is available at three distinct, and yet independent levels: PLC, I/O Server, and Graphics Server. By independent, we mean redundancy can be implemented at all, or any sub-set of the three levels, as shown in Figure 1 below Client Workstations Graphics Servers I/O Servers Dual-ported PLCs Figure 1: Three level redundancy in Adroit PLC Redundancy To implement PLC-level redundancy, either dual-ported PLCs are required, or alternatively completely redundant PLCs can be used. Figure 1 shows single, nonredundant PLCs, each with a primary and secondary communication channel.

To configure PLC level redundancy, all you need do is check the Enable Secondary option in the PLC driver configuration as shown below. The screenshots show a PLC(s) having two different IP addresses. It is also possible with some PLC models to use the same IP address but connect to different PLC ports. I/O Server clustering With reference to Figure 1, the central blue rectangles represent different physical (or virtual) machines forming a dual-redundant pair. Inside each machine are two server processes an I/O server (Agent Server) and a Graphics server (VIP Server), represented by the light grey rectangles. Although not represented in Figure 1, it is possible to run the I/O server and Graphics server processes in different machines. The I/O servers are responsible for performing the usual range of SCADA functions: scanning the PLCs, maintaining a real-time and historical database of process values, checking for and managing alarm conditions in process values, etc. An I/O Server is also responsible for making real-time and historical values available to the Graphics servers for onward transmission to Client Workstations or HMIs, as well as receiving process value updates originating in the HMIs, e.g. controls and set-point changes, etc. In a dual-redundant configuration, an I/O server needs to communicate in peer-to-peer fashion with its partner I/O server on the other machine. This is represented by the horizontal arrow in Figure 1, linking the I/O servers. A number of options are possible when configuring this peer-to-peer I/O Server communication. These are shown on the configuration form below: Server Type Select Cluster Server to enable the dual-redundant I/O server functionality Cluster Name Make sure the cluster name for the two I/O servers is the same Enable client runtime transaction shadowing Check this option if you want control and set-point value changes shadowed across to the partner server Shadowed scanning This means PLC values acquired by the duty master server are shadowed across to the partner standby server

Parallel scanning This means PLCs are scanned in parallel by both master and standby server. You also have the option of deciding whether to write out control and set-point values when in standby mode Manual master mode assignment At start up, I/O Servers initially take on the standby role, and if the Manual master mode assignment option is selected, then the server will stay in standby until something explicitly changes it to master Automatic master mode assignment This is the usual option, and means that after a configurable post-startup delay, a standby server will automatically promote itself to master if a partner server cannot be found that is already in master mode Project Name This is a way of allowing I/O Servers running on the same LAN to be independent, i.e. by having different project names. In other words to ensure that a pair of servers participate in a dual-redundant cluster, you need to make sure that their project name settings are the same Server Name Every I/O server running on a given LAN must have a unique agent server name. If not you will encounter an error starting up your server if it finds another server with the same name The implication so far, in all the discussions of I/O server redundancy, is that servers exist on the same LAN. But it is also possible for I/O Servers to run on different geographically separate network domains. In this case a separate set of configuration options exist.

These are shown below, and are accessed by clicking the Options button next to the Server Project Name setting Working up from the bottom of the screenshot above Enable remote servers to automatically detect this server This is the default setting (checked) and assumes servers exist on the same LAN and can see each other by exchanging UDP broadcast messages Explicit connections (broadcasts not visible) Essentially, this option allows you to specify your cluster partner by explicitly defining its physical details like machine name and server name. This is because UDP broadcast messages cannot travel between different network domains Additional Connections (using visible broadcasts) It is also possible to connect to servers on the same LAN, but running with different project names. The reason for this option has do with Adroit s distributed tag database capability, whereby all servers with the same project name interconnect and share their tag databases. If there are a large number of such servers, then the total number of network interconnections can become very large. To prevent this, we stop servers from automatically connecting, by having differing project names. By then explicitly listing the projects/servers to connect to, we can control exactly which servers connect to each other

Graphics Server clustering Clustering at the Graphics server level provides two benefits: Redundancy - which, like I/O Server clustering, provides for high-availability and resilience Load-balancing - which improves performance by allowing multiple Graphics servers to share their workloads The first configuration aspect to be considered is the I/O server connections, assuming dual redundant I/O servers have been configured. As the screenshot below shows, this is done via the SmartUI Designer s Enterprise Manager, where the Adroit datasource is specified to be of type Redundant, and the machine and agent server names are explicitly configured. This results in the Adroit datasource icon showing up bright green, and is represented in Figure 1 by the diagonal arrows For the purpose of clustering the Graphics servers themselves to allow redundancy and loadbalancing, the only thing you need do is change the ServerName setting in the Server/Service Advanced section in Config Editor to a common name, something like Cluster1, as shown below

The final consideration under Graphics server clustering has to do with letting the Client HMI Operator applications know that they are to connect in to a cluster of Graphics servers. This is done under Operator Cluster settings as shown below. Firstly you need to check the option specifying clustering and then choose the cluster name that the Graphics servers are running under, e.g. Cluster1. Next you need to provide a list of machine names running the Graphic server processes, of which there will be two in a dual-redundant configuration In Conclusion Carrying out all of the aforementioned dual-redundant configuration options will provide resilience, high-availability, and optimum performance from a pair of physical or virtual server machines. By virtue of load-balancing, assuming both servers are operational, the graphics processing load applied to the servers by the client HMI connections will be evenly distributed across the two machines. If the duty master server should fail for whatever reason, the active and fully in-sync standby machine will detect this and promote itself to master mode. Client HMI workstations running the SmartUI Operator application will see the change in master machine and bumplessly reconnect to the newly promoted master. Finally with PLC redundancy configured at the driver level, if any of the PLC connections should fail the driver will automatically switch to the secondary channel. All changes like this in the twin system state are fully monitored, and can be alarmed and logged, etc., just as process values would be alarmed and logged. This results in a manageable, highly available, resilient solution, ideally suited to industries demanding this kind of integrity. Solutions of this type have been successfully deployed on several mission critical applications in the defence, marine, power and nuclear sectors.