STM-1 Synchronous Digital Multiplexer and Multiservice Access Node



Similar documents
DXC Family. Multiservice Access Node FEATURES

DXC-8R/10A/30 Multiservice Access Nodes

Megaplex-2100/2104 Modules ML-1/2E1/T1, MLF-1/2E1/T1

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3

Kilomux-2100/2104. Modular integrating access multiplexer for data, voice, fax and LAN. Data Sheet. The Access Company

High-density rack with SNMP management provides E1/T1 and Ethernet services over copper and fiber. Data Sheet

Optimux-1553 Fiber Multiplexers for 3 E3/T3 over STM-1/OC-3

Optimux-34, Optimux-25

Optimux-134, Optimux-125

FCD-IP E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

FCD-E1E Managed E1 and Fractional E1 Access Device

Optimux-1551 Fiber Multiplexer for 63E1/84T1 over STM-1/OC-3

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

Optimux-134, Optimux-125

E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

FCD-IP E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

Where to buy > See the product page > Data Sheet. E1/T1 or Fractional E1/T1 Modular Access Device with Integrated Router

WEB RANger-II Internet Access Router

IPmux-1E TDM Pseudowire Access Gateway

Loop Telecom. Total Access Solutions for Enterprise Network, Cellular & Gateway Operator.

White Paper. OPCOM3500 Multi-Service Access Platform INTRODUCTION CHARACTERISTICS

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

VCL-MX Version 6 DXC 80 T1, 120Mbps Digital Access Cross Connect Switch. System Guide. VCL-MX Version 6 - T1 120Mbps Voice & Data Multiplexer

VALIANT COMMUNICATIONS LIMITED

SOLUTIONS FOR AN EVOLVING WORLD IMUX T1/E1 Multiplexer. with common logic redundancy IMUX 2000 T1/E1 1

FALCO. Broadband Groomer. F-330 Series. Applications. Access system for:

TDMoEthernet. Description

Public Network. 1. Relatively long physical distance 2. Requiring a service provider (carrier) Branch Office. Home. Private Network.

SOLUTIONS FOR AN EVOLVING WORLD IMUX 2000 T1/E1 MDACS. Cross-Connect Switch IMUX 2000 T1/E1 1

DataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs

2-port STM-1/OC-3 Channelized E1/T1 Line Card for Cisco Series Internet Routers

How To Connect A G.711 To A G711 Network With A Gbnet (G.723) (Gbnet) (Geo) (Ipnet) And Gb Net (G723.1)

F2400 FOM II Series Fiber Optic Modem Technical Manual

Loop-IP6700 TDMoEthernet

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

ANT-20, ANT-20E Advanced Network Tester PDH MUX/DEMUX

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

INTRODUCTION TO MEDIA CONVERSION

Loop-IP6700 TDMoEthernet

TrueAlarm Fire Alarm Systems

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

ORION TELECOM NETWORKS INC. T1

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

24-Port Channelized E1/T1 Line Card Overview

Updated March 2013 UCC Ensuring the Reliability of the Electric Power Grid. T1/E1 Multiplexer with Common Logic Redundancy

8-Port E3/DS3 ATM Line Card Overview

Xpress2500 Access System

Loop-V4300 MINI DACS E1/ T1 CONVERTER

T3 Mux M13 Multiplexer

Power network telecommunication

Intraplex T1 CrossConnect System & Server Installation and Operation Manual Issue 1.1, December 2001

FlexDSL MiniFlex. SHDSL.bis Up to 30Mbps Ddd. Ethernet. Features. Possible Applications

Product Overview. Features CHAPTER

Cisco 8-Port Channelized T1/E1 Shared Port Adapter

FlexPoint T1/E1 Copper to Fiber Line Driver

BROADBAND AND HIGH SPEED NETWORKS

IP Express Multi-Service IP DSLAM

DataSMART 681, 696 and 698

SDH and WDM A look at the physical layer

T1 Networking Made Easy

1. Overview. 2. F-bit Utilization

Course 12 Synchronous transmission multiplexing systems used in digital telephone networks

FlexDSL MiniFlex. SHDSL.bis and Optical Mini DSLAM. SHDSL.bis and Fiber Up to 300Mbps Ddd. Ethernet. Features

WANic 800 & or 2 HSSI ports Up to 52 Mbps/port. WANic 850 & or 2 T3 or E3 ports Full-speed CSU/DSU. WANic 880.

Optical Product Families

Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers

Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers

Business Access. Universal Line Access Family

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card for Cisco 2821, 2851, and 3800 Series Integrated Services Routers

Tellabs 1000 Multiservice Access Platform (MSAP) Secure high revenue TDM services with low cost integrated MSAP

TACTICAL FIBER OPTIC MODEMS U.S. Army and ANSI Standards

BridgeWay Fixed Base Radio Telecom VoIP Gateway

cpci cfxo3120 FXO/FXS VoIP Gateway

Octal T1-10/100 RIOP Installation Guide

Appendix D T1 Overview

Cisco Channelized T1/E1 and ISDN PRI Modules

SDH and WDM: a look at the physical layer

FlexGain Platform. Universal Access Platform. SHDSL.bis and Fiber Access Platform Ddd & Management. Features

T1 Backhaul Connectivity Solution All Products :: Application Note

FlexDSL MiniFlex. SHDSL.bis and Optical Mini DSLAM. SHDSL.bis and Fiber Up to 300Mbps Ddd. Ethernet. Features

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card

CTC Union Technologies Co.,Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St., Neihu, Taipei 114, Taiwan

Loop-IP6702 TDMoEthernet

SOHOware Long Reach Ethernet (LRE) Solution

E2-E3 E&WS MLLN. For internal circulation of BSNLonly

CERAGON. Broadband Wireless Network Solutions GHz Mbps SONET/SDH IP ATM Fast Ethernet Built-in ADM

Cisco 3600 Series Multiservice Platforms

Network+ Guide to Networks 6 th Edition. Chapter 7 Wide Area Networks

Cisco CCNA Optional Semester 4 Labs Wide Area Networking LAB 1 T1 TSU WAN LINK OVERVIEW - Instructor Guide (Estimated time: 30 minutes)

FlexDSL MiniFlex. SHDSL.bis and Optical Mini DSLAM. SHDSL.bis and Fiber Up to 300Mbps Ddd. Ethernet. Features

TECHNICAL SPECIFICATION TSPE 2084 U 0 INTERFACE FOR ISDN BASIC ACCESS

OPERATION MANUAL INSTALLATION AND DXC-4. E1/T1 Grooming Device. Version 1.0. Innovative Access Solutions

Alcatel-Lucent 1645 AMC Access Mutiplexer Compact. Cost-effective and compact STM-1/4 multiservice metro access

Product Information D23m Digital I/O System

Starlink 9003T1 T1/E1 Dig i tal Trans mis sion Sys tem

WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor

BridgeWay Fixed Base Radio Telecom VoIP Gateway

Transcription:

STM-1 Synchronous Digital Multiplexer and Multiservice Access Node FEATURES SDH transmission solution for access networks, expanding Local Loops to 60 km/37 miles Digital cross-connection for up to 960 timeslots on copper, fiber or HDSL links Programmable DS0 non-blocking cross-connection E1/T1 conversion supports A-law/µ-law and signaling conversion Transmission of T1 traffic over E1. Complies with ITU-T G.802 Broadcast support Flexible configuration as an STM-1 terminal or an add&drop multiplexer (ADM) with full cross-connectivity and PDH interfaces Supports centralized management, including configuration, service, performance, security and fault management Integrated management system supporting RAD s Multiservice Access Platform (MAP) equipment Telnet support (DXC subsystem only) Separate dial-in/dial-out port (DXC subsystem only) Accurate timing transfer to access equipment Optional redundancy for common logic and power supply 1:1 tributary protection switching Traffic grooming into E3/DS3 uplinks Inverse multiplexing module supports up to 8 E1/T1 trunks RADview management system on PC or UNIX (HP OpenView) platform Local Loop access solution with LTU or CSU options for extended range, built-in fiber optic or HDSL modems TFTP support for common logic software upgrade Test and monitoring at any port

GENERAL DESCRIPTION DXC-STM-1 is a hybrid version of the R-STM-1E multiplexer and the DXC-30 digital cross-connect, assembled in a single integrated chassis. The system features both DXC 1/0 cross-connect and SDH ADM capabilities. DXC-STM-1 can be deployed in access nodes as a terminal multiplexer (TM) or add&drop multiplexer (ADM). It enables expansion of the Local Loop up to 60 km/37 miles, creating a transmission layer fully compatible with regional and national SDH networks. DXC-STM-1 is available with standard G.703 coaxial or optical short/long haul aggregates. APPLICATION SDH transmission supports a full range of access systems, including Remote Subscriber Units (RSUs), Digital Line Carriers (DLCs), Digital Cross-Connect (DACS) and service multiplexers. DXC-STM-1 is fully compatible with 34 Mbps and 45 Mbps PDH signals, SDH microwave radio relays and existing SDH infrastructure. DXC-STM-1 supports the whole range of SDH network topologies: Point-to-Point Chain STM-1 ring / folded ring STM-4/16 ring / STM-1 structured ring-star and ring-ring. DXC-STM-1 facilitates centralized management of the access network. Centralized management combines the powerful RADview network management application in the SDH transmission layer with the access equipment manager of a specific application. The access equipment manager uses embedded management channels for communication with remote access equipment. Centralized management enables the building of flexible, responsive and optimized SDH access networks to fit any customer needs. The 2 Mbps output signals of DXC-STM-1 can be resynchronized by the multiplexer clock. In addition, pointer justification events can be filtered out, eliminating phase hits. This creates an accurate signal, clear of phase hits and suitable for synchronization of access equipment. Since the SDH network is usually synchronized by the national synchronization network, this accurate timing is transferred to the access equipment. Network Management Station PSTN/ISDN Network Other Service Network Megaplex-2200 DXC-30 Business Customers SDH Network STM-n Residential Customers STM-1 PABX STM-1 STM-1 DXC-STM-1 FCD-IP ISDN POTS ISDN DXC-STM-1 DXC-STM-1 n x 64 kbps Megaplex-2200 Megaplex-2100

STM-1 Synchronous Digital Multiplexer and Multiservice Access Node EXTENSION MODULES ADM SECTION The interface capacity of DXC-STM-1 can be expanded from its basic 21x2 Mbps configuration of the ADM section, by adding the following extension modules (ordering options): R-STM-1E-EXT42 expands the ADM capacity from 21x2 Mbps (21 E1) to 63x2 Mbps (63 E1) tributary R-STM-1E-EXT34 provides three E3 (3x34 Mbps) tributary R-STM-1E-EXT45 provides three T3 (3x45 Mbps) tributary I/O MODULES CROSS-CONNECT SECTION DXC-STM-1 supports the following plug-in interface modules supporting n x 56/64 kbps, T1, E1, T3 or E3 transmission over copper, fiber or HDSL (see enclosed data sheets for detailed specifications): DT1 and DT1B, the two-port T1 interface modules, support both D4 or ESF framing formats. For long-range applications, a CSU option is available. The DT1B version provides BERT, loopback per timeslot, and 1:1 redundancy. DT1 and DT1B are available with both copper and fiber optic DE1 and DE1B, the two-port E1 interface modules, support both 2 and 16 frames per multiframe with CRC-4 and HDB3 line code. For long range applications, a CSU option is available. The DE1B version provides BERT, loopback per timeslot, and 1:1 redundancy. DE1 and DE1B are available with both copper and fiber optic DT3, the single-port T3 interface module, supports multiplexing of up to 28 T1 channels into a T3 frame with C-bit parity or M13. DT3 is available with either copper or fiber optic interface. DT3/747, the single-port T3 interface module (DCL.2 only) supports submultiplexing of 21 E1s into a single DS3 data stream. Mixed (E1 and T1) traffic applications are also available. The DT3/747 module is available with either copper or fiber optic interface. DE3, the single-port E3 interface module, supports multiplexing of up to 16 E1 channels into an E3 frame. DE3 is available with either copper or fiber optic interface. DHS, the two-port n x 56/64 kbps data module, provides two high speed synchronous data channels. Each channel can be independently ordered as V.35, V.11/RS-422 or X.21 interface. ETH bridge and IP router versions are also available. Synchronous channels support data rates of n x 56 kbps, or n x 64 kbps, where n is 1 to 24 for T1 and 1 to 31 for E1. DIM, the Digital Inverse Multiplexer module, working in conjunction with DE1, DE1B, DT1, DT1B, DE3, DT3, D8E1, D8T1 or DFSTM-1 interface modules, enables transmission of high speed signals over up to eight E1/T1 lines. This is achieved by breaking down the high speed (RS-530, V.35, X.21, HSSI, E1 and ETH) signals over the multiple E1/T1 lines and routing these signals over different paths or facilities, while ensuring transmission integrity. DHL/E1, the two-port HDSL module, uses HDSL technology to extend the range of DXC up to 4.0 km (2.5 miles) over 24 AWG (0.5 mm), 4-wire copper cables. It works opposite other RAD products with HDSL technology. DHL/E1/2W, the two-port HDSL module, uses HDSL technology to extend the range of DXC up to 3.0 km (1.9 miles) over 24 AWG (0.5 mm), 2-wire copper cables. It can work in conjunction with HCD-E1/2W, to extend the range of the traditional subscriber loop while saving on the copper infrastructure. DHL/T1, the two-port HDSL module, uses HDSL technology to extend the range of DXC up to 4.0 km (2.5 miles) over 24 AWG (0.5 mm), 4-wire copper cables. It works opposite other RAD products with HDSL technology. D4E1 and D8E1, the 4- or 8-port E1 interface modules, provide 4 or 8 E1 links over copper cables, supporting E1 or Fractional E1 rates. D4T1 and D8T1, the 4- or 8-port T1 interface modules, provide 4 or 8 T1 links over copper cables, supporting T1 or Fractional T1 rates. D8U, the eight-port ISDN "U" interface module, provides independent ISDN "U" ports, each supporting 2B + D channels, for total payload data rate up to 128 kbps per port. DFSTM-1, the fractional STM-1 module, provides direct access to the Synchronous Digital Hierarchy (SDH) transmission cores, at the STM-1 level (155.520 Mbps). SPECIFICATIONS SDH Level STM-1 (155.520 Mbps) Multiplexing Structure Complies with Figure 1.1 in G.709 standard Cross-Connect Level VC-12 or multiples (ADM) 960 TS (1/0) Error Performance Complies with G.826 High grade Jitter Aggregate line: complies with G.783, G.823, G.958 Tributary line: complies with G.783, G.823

Table 1. DXC I/O Modules Module Technology Description DE1 Copper / Fiber optic Two-port E1 interface module DE1B Copper / Fiber optic Two-port E1 interface module with BERT DT1 Copper / Fiber optic Two-port T1 interface module DT1B Copper / Fiber optic Two-port T1 interface module with BERT DE3 Copper / Fiber optic One-port E3 interface module DT3 Copper / Fiber optic One-port T3 interface module DT3/747 Copper / Fiber optic One-port T3 interface module with G.747 submultiplexing (DCL.2 only) DHS Copper Two-port n x 56/64 kbps data module DIM Digital inverse multiplexer module DHL/E1 HDSL 4-wire Two-port link 2.048 Mbps HDSL module, extended range DHL/T1 HDSL 4-wire Two-port link 1.544 Mbps HDSL module, extended range DHL/E1/2W HDSL 2-wire Two-port link 2.048 Mbps 2-wire HDSL module, for up to 3.0 km D4E1, D8E1 Copper Four- or eight-port E1 interface modules D4T1, D8T1 Copper Four- or eight-port T1 interface modules D8U Copper Eight-port ISDN "U" interface module DFSTM-1 Copper / Fiber optic Fractional STM-1 module (DCL.3 only) DXC-STM-1 Rear View

STM-1 Synchronous Digital Multiplexer and Multiservice Access Node Indicators ADM subsystem: ACT normal operation FLT malfunction detected or software downloading PRG management accesses NVM card ALM transmission alarm ACK current alarms acknowledged LASER ON optical aggregate is transmitting DXC subsystem: MAJOR ALARM MINOR ALARM TEST test activated ON-LINE on the power supply and common logic modules DXC I/O module indicators (see separate data sheets) Power Supply ADM subsystem: Input voltage: -35 VDC to -75 VDC Nominal power source: -48 VDC to -60 VDC Typical power consumption: See Table 1. DXC subsystem: 100 to 240 VAC, 47 to 63 Hz -48 VDC nominal Diagnostics Performance monitoring according to G.826, G.784 External alarms Physical Compatible with ETSI rack Height: 32 cm/12.2 in (7U) Width: 43.8 cm/17 in Depth: 25.5 cm/10 in Weight: less than 18.0 kg/40 lb ELECTRICAL AGGREGATE G.703, paragraph 12 CMI 155.520 Mbps BNC OPTICAL AGGREGATE G.957, Table 2 optical aggregate Transmission Line Dual fiber optic cable Operating Wavelength As per G.707, G.958, see Table 2. 155.520 Mbps ± 4.6 ppm FC/PC TRIBUTARIES 2 Mbps G.703, paragraph 6 2.048 Mbps HDB3 Frame Unframed DB-25 Optical Transmit/Receive Characteristics See Table 2. 34 Mbps G.703, paragraph 8 34.368 Mbps HDB3 Frame Complies with G.751 DIN 1.6 45 Mbps ANSI T1.105.03-1994 44.736 Mbps B3ZS DIN 1.6 MANAGEMENT CONFIGURATIONS Intergrated Network Management RADview software on dedicated SUN workstation Network Element Monitoring Element Manager software on PC or laptop for ADM subsystem configuration and RADview element management on PC or UNIX for DXC subsystem configuration (UNIX only for DCL.3) Note: For both UNIX and PC management a minimum of the RV-EEM-SW/1 is required for initial IP address assignment. Table 1. Power Consumption of Aggregates and Extension Modules R-STM-1/1E Aggregate/Extension Module Typical Power Consumption Typical Power Dissipation Optical modular ADM with 21x2 Mbps Channels Electrical modular ADM with 21x2 Mbps Channels Extension module 42x2 Mbps Extension module 3x34 Mbps 38W 42W 14W 11W 35W 39W 20W 20W Extension module 3x45 Mbps 16W 20W Optical non-modular ADM with 21x2 Mbps Channels 38W 35W Optical Interface Table 2. Optical Transmit/Receive Characteristics Wavelength [nm] Receiver Sensitivity [dbm] Output Power [dbm] FC13L 1310-30.0-14.0 to -9.0 FC15L 1550-35.0-4.5 to -0.5

STM-1 Synchronous Digital Multiplexer and Multiservice Access Node ORDERING DXC-STM-1/?/*/~/+ Basic unit includes DXC-30 chassis, one power supply, one DCL.2 common logic module and R-STM-1E (no DXC I/O modules and no R-STM-1 extension modules) DXC-STM-1-3/?/*/~/+ Basic unit same as above, but with DCL.3 common logic module R-STM-1E-EXT/42 42 x E1 extension module R-STM-1E-EXT/34 3 x E3 extension module R-STM-1E-EXT/45 3 x T3 extension module CBL-R-STM-1 R-STM-1E splitter cable (splits the DB-25 tributaries connector into 11 x RJ-45). Cable length is 2m (6 ft). Note: One cable is included with each R-STM-1E unit. Two cables are included with each EXT/42 module. CBL-R-STM-1/ALM Alarm cable for R-STM-1E. Note: One CBL-R-STM-1/ALM cable is included in R-BASIC-INST-KIT. CBL-R-STM-1E/DIN/10 Open-ended coaxial cable with DIN 1.6/5.6 MS connector. Cable length is 10m (33 ft) CBL-R-STM-1E/DIN/20 Open-ended coaxial cable with DIN 1.6/5.6 MS connector. Cable length is 20m (66 ft) Note: Two CBL-R-STM-1E/DIN cables are required per port on EXT/34 and EXT/45 expansion modules. R-BASIC-INST-KIT Includes RAP, circuit breakers, alarm and power cables and mounting kit for rack and subracks R-STM-1/a/b Adapter shelf for up to three AC-DC converters RV-EEM-SW/c Element Manager for Win 95/98 PC and small networks of up to 10 network elements 2001 2002 RAD Data Communications Ltd. All other trademarks are the property of their respective holders. RV-EINM-SW/d Integrated Network & Element Manager for UNIX platform, supporting MAP products and unlimited network elements. Note: When ordering RV-EINM-SW, please note that you must also purchase the adequate RV-IN-HW, RV-EEM-SW/1 for IP address configuration and HPOV license. RV-IN-HW/$ UNIX workstation (mandatory for RV-EINM-SW) I/O MODULES See separate data sheets SYSTEM MODULES DXC-30M-CL.2/? DCL.2 Common Logic No.2 Module with enhanced management, FLASH EPROM for upgrade DXC-30M-CL.3/? DCL.3 Common Logic No.3 Module with enhanced management, FLASH EPROM for upgrade DXC-30M-PS/~ Power supply module ORDERING OPTIONS? Specify management port interface: UTP for Ethernet 10BaseT (DCL.2) or Ethernet 10/100BaseT (DCL.3) BNC for Ethernet 10Base2 (DCL.2) V24 for V.24/RS-232 dial port * Specify R for power supply and common logic redundancy ~ Specify DXC section power supply: AC for 100 to 240 VAC operation 48 for -48 VDC operation + Specify ADM section interface CX for electrical interface with coaxial BNC connectors FC13L for 1310 nm, single mode, laser diode with FC/PC connectors FC15L for 1550 nm, single mode, laser diode with FC/PC connectors a Specify ADM section power supply 115 for 100 VAC to 120 VAC operation 230 for 200 VAC to 240 VAC operation b Specify number of power supplies on shelf: b=1, 2, or 3. c Specify number of network elements for RV-EEM to be managed: 1,2,, 10 d Specify number of network elements for RV-EINM to be managed: 1,2, e Specify Integrated Network Workstation configuration 1 for Ultra 5, 256MB, 1 CPU, 2 ETH cards, RAID, UPS, modem, 21 monitor (up to 50 NEs) 2 for Ultra 2/60, 512MB, 1 CPU, 21 monitor (up to 100 NEs) 21 for Ultra 80, 1GB, 1 CPU, 21 monitor (up to 100 NEs) 3 for Ultra 60, 1GB, 2 CPU, 21 monitor (up to 250 NEs) 31 for Ultra 80, 1GB, 2 CPU, 21 monitor (up to 250 NEs) 4 for Ultra 80, 1GB, 4 CPU, 21 monitor (up to 500 NEs) 41 for Enterprise 3500, 2GB, 4 CPU, 5 ETH cards, RAID, UPS, modem, 21 monitor (up to 500 NEs) 772-112-02/02 Specifications are subject to change without prior notice.