DICOM Conformance Statement CBS Images and Worklist Version 2.01



Similar documents
DICOM Conformance Statement FORUM

DICOM Conformance Statement. Version: 1.0

DOLPHIN DICOM IMAGING DICOM CONFORMANCE STATEMENT

DICOM 3.0 Conformance Statement

ONIS 2.0 DICOM CLIENT. DICOM 3 Conformance statement

Technical Publication. DICOM Conformance Statement. DICOM Proxy 2.0. Document Revision 3. October 20, Copyright Brainlab AG

HP Medical Archive Solutions DICOM Conformance Statement. January 2007 (Third Edition) Part Number T

Infinity Medical Image Server

AGFA MEDICAL IMAGING DICOM Conformance Statement

DigitizingStation. DICOM V3.0 Conformance Statement

Version 8 DICOM Conformance Statement. Version 3.04, September 2014

g GE Medical Systems Advantage Cluster Storage / Archive System Release 1 v Conformance Statement Direction number: Revision: 2

Medflow Imaging DICOM Server

MiPACS Storage Server Conformance Statement Version

DICOM Conformance Statement Merge Eye Care PACS v. 4.0

DICOM Conformance Statement

Candelis, Inc. DICOM Conformance Statement. ImageGrid Storage Server

DICOM Conformance Statement

DICOM Conformance Statement

Dx MM DICOM 3.0 Conformance Statement

Hologic Physician s Viewer 7.0 DICOM Conformance Statement

GE PACS Conformance Statement for DICOM v3.0

DICOM Conformance Statement For Diagnostic Review Workstation Software Version 5-x MAN-00546

DICOM Conformance Statement. GDxPRO

Technical Publications

DICOM Conformance Statement

AquariusNET DICOM Conformance Statement. DICOM Conformance Statement. AquariusNET 4.4. Rev B

Philips Medical Systems DICOM Conformance Statement

GENIE Acquisition R3.1 Conformance Statement for DICOM v3.0

ClearCanvas ImageServer DICOM Conformance Statement

Technical Publications

DICOM 3.0 Conformance Statement

Centricity TM RISi DICOM Conformance Statement

DICOM CONFORMANCE STATEMENT FOR ZIOSTATION 2.0

Technical Publications

Xeleris 2.0 Conformance Statement for DICOM V3.0

DICOM Conformance Statement

DICOM 3.0 CONFORMANCE STATEMENT

Technical Publications

MammoView 1.5. DICOM Conformance Statement 1.0. medigration GmbH All rights reserved

DICOM Conformance Statement

Technical Publications

Table of Contents. Version History

DICOM CONFORMANCE STATEMENT FOR ZIOCUBE 1.0

CARESTREAM PACS Suite (Client, Server, and CD Direct) Version DICOM Conformance Statement

Varian System Server. DICOM Conformance Statement

DICOM Conformance Statement

Digital Imaging and Communications in Medicine (DICOM) Supplement 119: Frame Level Retrieve SOP Classes

ConnectPro for CT/i 4.0 Systems Conformance Statement for DICOM v3.0

DICOM Conformance Statement

DICOM CONFORMANCE STATEMENT STORAGE SCU, Q/R SCP, PRINT SCU & STORAGE COMMITMENT SCU FOR TOSHIBA SUPERCONDUCTING MRI SYSTEMS (MIIMR0001EAB)

How To Connect Ifa Dicom To An Ophthalmology System

DICOM Conformance Statement

DICOM Conformance Statement

Printlink5-ID_IV. DICOM 3.0 Conformance Statement PRINT MANAGEMENT SYSTEM CODE NO Manufacturer:

AGFA HEALTHCARE DICOM Conformance Statement

HDI 4000 Ultrasound System

DICOM. Conformance Statement. Envisor Software Version C.0

Technical Publications

How To Write A Dicom Dicoma Dicomm Test Article

Digital Imaging and Communications in Medicine (DICOM) Part 4: Service Class Specifications

DICOM Conformance Statement

DICOM CONFORMANCE STATEMENT

Centricity Enterprise Web 3.0 DICOM Conformance Memo DOC

DICOM CONFORMANCE STATEMENT

SwissVision TR4000. DICOM Conformance Statement File Media Storage Services. Program Version 9.3 or later Document Revision 1.2.

JiveX Enterprise PACS Solutions. JiveX HL7 Gateway Conformance Statement - HL7. Version: As of

DICOM Conformance Statement. Veradius Unity

Implementation of DICOM Modality Worklist at Patient Registration Systems in Radiology Unit

Supplement 113 Transport

Tools for DICOM Implementation

OpenEMR: Achieving DICOM Interoperability using Mirth

Introduction CDR Dicom for Windows is designed as a fully functional DICOM (Digital Imaging Communications of Medicine) based client-server

DICOM Conformance Statement. DICOMscope 3.5. Software developed by: M. Eichelberg 1, K. Kleber 2, J. Riesmeier 1, A. Schröter 2, A.

MedDream SendToPACS USER S MANUAL (version 1.15)

QueryRetrieveSCU Queries image archives and controls remote retrieve of images to specified destination. (= SCU of Query/Retrieve SOP classes).

DICOM: Definitions and Testing

DICOM Correction Proposal

NEMA Standards Publication PS 3 Supplement 41. Digital Imaging and Communications in Medicine (DICOM) Digital Signatures

Liberate Your Image Data

DICOM Conformance Statement. CT Tomoscan M/EG/EG Compact Release 4.0. Document Number March 2000

Cenova Image Analytics Server DICOM Conformance Statement

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH

SIGNA PROFILE CONFORMANCE STATEMENT

Digital Imaging and Communications in Medicine (DICOM) Part 1: Introduction and Overview

PARCA Certified PACS Interface Analyst (CPIA) Requirements

NETWORK MANAGEMENT FOR PICTURE ARCHIVING AND COMMUNICATION SYSTEMS

DICOM Conformance Statement

DICOM Conformance Statement

Medical Imaging in IDL

DICOM Digital Imaging and Communications in Medicine

DICOM- an overview with an emphasis on Therapy

MiPACS Storage Server

Network Management for Picture Archiving and Communication Systems (PACS)

Digital Imaging and Communications in Medicine (DICOM) Part 1: Introduction and Overview

Workstation, Server Hosted

IHE Eye Care Technical Framework Supplement. Basic Eye Care Workflow (B-EYECARE) Trial Implementation

Digital Imaging and Communications in Medicine (DICOM) Part 10: Media Storage and File Format for Media Interchange

DICOM Conformance Statement Print Management Service Class FUJI NETWORK PRINT SERVER FN-PS551

Extracting, Storing And Viewing The Data From Dicom Files

Transcription:

DICOM Conformance Statement CBS Images and Worklist Version 2.01 Compulink Inc. 1100 Business Center Circle Thousand Oaks, CA 91320 Internal document number: 4226-000-000-001 rev 1 Creation Date: 20131101 Last Modificatin: 20150301 www.compulinkadvantage.com

1 CONFORMANCE STATEMENT OVERVIEW CBSIW is a DICOM Application Entity system used for receiving and sending of DICOM Images and Modality Worklist queries and results. The system conforms to the DICOM standard to allow the sharing of medical information with other digital imaging systems. Note: This document is intended for informational use only and is not intended as an obligation to provide services or guarantee interoperability with other software or hardware platforms. Document: DICOM Conformance Statement CBSIW 1.0.doc Page 2 of 19 Copyright: Compulink, Inc. SOP Classes User of Service (SCU) Provider of Service (SCP) Verification Verification No Yes Workflow Management Modality Worklist Information Model - FIND No Yes Image Transfer C-Move C-Store Yes Yes

2 TABLE OF CONTENTS 1 Conformance Statement Overview 2 Table of Contents 3 Introduction 4 Network Messaging 5 Media Interchange 6 Support Of Character Sets 7 Security

3 Introduction 3.1 Revision History Document Version Author Date Change 1.0 Robert Rosen 2010-09-25 Initial revision for CBSIW v1.0 3.2 Audience This document is intended for hospital staff, health system integrators, software designers or implementers. The reader should have a basic understanding of DICOM. 3.3 Remarks If another device matches this conformance statement based on the comparison with its own conformance statement, there is a chance, but no guarantee, that they interoperate. DICOM only deals with communication; it does not specify what is needed for certain applications to run on a device. 3.4 Definitions, Terms and Abbreviations Abbreviation AE AET DICOM CBS [EHR] EHR ILE IOD Definition Application Entity Application Entity Title Digital Imaging and Communications in Medicine Compulink EHR Electronic Health Record management system Implicit Little Endian Information Object Definition MWL NB PMS SCP SCU SOP SW TCP/IP UID Modality Work List Network Broker Practice Management System Service Class Provider Service Class User Service Object Pair, pair of user and provider. Software Transmission Control Protocol / Internet Protocol Unique Identifier 3.5 References Digital Imaging and Communications in Medicine (DICOM), NEMA PS 3.1-3.18, 2008

4 Network Messaging 4.1 Implementation Model SOP Class Name SOP Class UID SCU SCP Verification 1.2.840.10008.1.1 No Yes Modality Worklist Information Model - FIND 1.2.840.10008.5.1.4.31 No Yes C-Store *see below No (mainly) Yes (mainly) 4.1.1 Expected Work Flow

4.1.2. Worklist Data Flow 4.1.2 Functional Definition of AEs 4.1.2.1 Verification CBSIW will respond to a DICOM C-Echo request from a remote AE in order to verify communication. 4.1.2.2 Modality Worklist Assuming that a scenario exists where a patient has been registered at a medical clinical environment using CBS EHR and a device test has been scheduled using the CBS EHR for a known device (DICOM Worklist capable). CBSIW waits for a remote AE connection (Association). Once a connection has been established, device may send a C-Find request for a Worklist given a set of search criteria. The CBSIW will work with the CBS EHR to return any

matching worklist results to the device using the DICOM networking protocol. The Worklist results contain data including Patient Id, Name, Date and time of Scheduled Procedure. 4.2 AE Specifications 4.2.1 CBSIW Application Entity Specification 4.2.1.1 SOP Classes 4.2.1.2 Associations Policies 4.2.1.2.1 General DICOM standard Application Context Name is DICOM 3.0. Application Context Name 1.2.840.10008.3.1.1.1 4.2.1.2.2 Number of Associations The CBSIW SW can be configure to use one AE Worklist related activities. Maximum number of simultaneous associations Limited by host OS performance. Recommended 25. 4.2.1.2.3 Asynchronous Nature CBSIW supports asynchronous communication (multiple outstanding transactions over a single Association). 4.2.1.3 Association Initiation Policy 4.2.1.3.1 Activity Verification (SCP) 4.2.1.3.1.1 Description and Sequencing of Activities The CBSIW AE will respond to Verification requests to provide a remote SCU with the ability to determine if the respective AEs are able to receive and handle DICOM requests. 4.2.1.3.1.2 Accepted Presentation Contexts Presentation Context Table Abstract Syntax Transfer Syntax Role Name UID Name List U I D L i s t Verification 1.2.840.10008.1.1 ILE 1.2.840.10008.1.2 SCP

4.2.1.4.1.3 SOP Specific Conformance Verification The CBSIW provides standard conformance to the DICOM Verification Service Class as an SCP. One of the following status codes are returned: Service Status Further Meaning Error Code Behavior Success Success 0000 Operation performed properly. 4.2.1.4 Activity Query Modality Worklist (SCP) 4.2.1.4.1 Description and Sequencing of Activities The CBSIW MWL AE will respond to DICOM C-FIND requests in response to a remote AE querying for a Modality Worklist. Before the CBSIW AE can respond to a DICOM Modality Worklist query, the integrated PMS/EHR must contain MWL items in the form of scheduled procedures/tests. 4.2.1.4.2 Accepted Presentation Contexts Presentation Context Table Modality Worklist Information Model - FIND Abstract Syntax Transfer Syntax Role Name UID Name List UID List 1.2.840.10008.5. 1.4.31 ILE 1.2.840.10008.1. 2 SCP C-Find Extended Negotiation is supported: For the field "Date-time matching" the value 1 is returned, meaning that this is supported by the CBSIW AE. 4.2.1.4.3 SOP Specific Conformance MWL The CBSIW MWL AE provides standard conformance to the DICOM Basic Worklist Management Service Class. The CBSIW application can be configured to use only one AE for MWL and all the other described transactions The following table contains detailed information on matching and returned keys: Description Tag Matching Type Scheduled Station AE Title (0040,0001) U S Scheduled Procedure Step Start (0040,0002) U CDT Date Modality (0008,0060) U S Requested Procedure ID (0040,1001) U S Accession Number (0008,0050) U S Patient's Name (0010,0010) U S * Patient ID (0010,0020) U S

Patient's Birth Date (0010,0030) U S R Patient's Sex (0010,0040) U S The following table contains the supported return keys: Description Tag Scheduled Procedure Step Sequence (0040,0100) >Scheduled Station AE Title (0040,0001) >Scheduled Procedure Step Start Date (0040,0002) >Scheduled Procedure Step Start Time (0040,0003) >Modality (0008,0060) >Scheduled Performing Physician's Name (0040,0006) >Scheduled Procedure Step Description (0040,0007) > Scheduled Protocol Code Sequence (0040,0008) >> Code Meaning (0008,0104) >> Code Value (0008,0100) >> Coding Scheme Designator (0008,0102) >> Coding Scheme Version (0008,0103) >Scheduled Procedure Step ID (0040,0009) Requested Procedure ID (0040,1001) Requested Procedure Description (0032,1060) Study Instance UID (0020,000D) Study Date (=Scheduled Procedure Step Start Date) (0008,0020) Study Time (=Scheduled Procedure Step Start Time) (0008,0030) Accession Number (0008,0050) Requesting Physician (0032,1032) Requested Procedure Code Sequence (=Scheduled Protocol Code (0032,1064) Sequence) > Code Meaning (0008,0104) > Code Value (0008,0100) > Coding Scheme Designator (0008,0102) > Coding Scheme Version (0008,0103) Referring Physician s Name (0008,0090) Patient's Name (0010,0010) Patient ID (0010,0020) Patient's Birth Date (0010,0030) Patient's Sex (0010,0040) Other Patient IDs (0010,1000) Ethnic Group (0010,2160) Patient Comments (0010,4000) The CBSIW MWL AE returns one of the following status codes in a C-FIND response: Service Status Further Meaning Error Code Description Refused No Such SOP class 0118 If a SOP Class is used, which was not negotiated. Unrecognized Operation 0211 Unrecognized value in Command Filed Failed Processing Failure 0110 Unexpected internal errors. Unable To Process C000 Unexpected internal

errors. Cancel FE00 The original requester canceled this operation. Pending Pending FF00 All Optional Keys are supported in the same manner as Required Keys. Success Success 0000 Operation performed properly 4.2.1.5 Activity C-STORE (*Mainly SCP) 4.2.1.5.1 Description and Sequencing of Activities The CBSIW MWL AE will respond to the DICOM C-STORE command. The C-STORE command is used to send Dicom Objects from one AE to another. External AEs should ensure that the Patient Id contained in the Dicom Object is valid and recognizable by CBSIW. Even though the CBSIW May have capability to perform Dicom C-Stores as an SCU using utilities, its main function is to receive key images directly from another AE. Thereby making its profile mostly as a recipient of C-Store messages. 4.2.1.5.2 Accepted Presentation Contexts Presentation Context Table Abstract Syntax Transfer Syntax C-STORE ILE 1.2.840.10008.1.2 SCP STORAGE CLASSES Secondary Capture Image Storage JPEGProces s1transfer Syntax 1.2.840.1000 8.1.2.4.50 Computed Radiography Image Storage SOP Class CT Image Storage JPEGProces s2_4transf ersyntax 1.2.840.1000 8.1.2.4.51 Ophthalmic Photography 8- Bit Image Storage Ophthalmic Photography 16- Bit Image Storage RLELossles stransfers yntax 1.2.840.1000 8.1.2.5 VL ImageStorage VL MultiFrameImageStorage VL EndoscopicImageStorage VL MicroscopicImageStorage

EncapsulatedPDFStorage Ophthalmic Photography 8 Bit Image Storage Ophthalmic Tomography Image Storage *Not an exhaustive list. 4.2.1.5.3 SOP Specific Conformance C-STORE The CBSIW AE provides standard conformance to the DICOM C-STORE Service Class. A White list can be used to restrict peers from sending C-STORE commands when in the SCP Role. 4.2.1.6 Activity C-MOVE (Mostly SCP) and C-Store(SCU) 4.2.1.6.1 Description The CBSIW MWL is focused mainly as a MWL server and storage recipient for key images. But at times it may use the DICOM C-MOVE and C-STORE in the role of SCU using the same presentation contexts as noted above with C- STORE as an SCP. It may perform these functions using ancillary utilities.

4.3 Network Interfaces 4.3.1 Physical Network Interface The physical network interface is provided by the host hardware and Operating System. 4.4 CONFIGURATION 4.4.1 AE Title/Presentation Address Mapping 4.4.1.1 Local AE Titles The mapping from AE Title to TCP/IP addresses and ports is configurable and set in the configuration xml file by Installation Personnel. Initial set to Cbs_IMS 4.4.1.2 Remote AE Title/Presentation Address Mapping You may edit the file PeerAEs.dat to add external IPAddresses and AE titles.

5.0 MEDIA INTERCHANGE CBSIW Will Send and Receive Dicom Image Files. 6 SUPPORT OF EXTENDED CHARACTER SETS CBSIW supports the following: ISO_IR 100 (ISO 8859-1:1987 Latin Alphabet No. 1 supplementary set) 7 SECURITY CBSIW is intended to be used behind a firewall within a secure environment. It is not intended to be accessible via global Internet IP addresses.