FAQ SHEET - LAYERS OF PROTECTION ANALYSIS (LOPA)



Similar documents
FAQ SHEET - OSHA REVISED HAZARD COMMUNICATION STANDARD (HCS) (29 CFR , MARCH 26, 2012)

CYBER SECURITY RISK ANALYSIS FOR PROCESS CONTROL SYSTEMS USING RINGS OF PROTECTION ANALYSIS (ROPA)

by Paul Baybutt and Remigio Agraz-Boeneker Primatech Inc. 50 Northwoods Blvd. Columbus, Ohio, USA

Designing an Effective Risk Matrix

USING INSTRUMENTED SYSTEMS FOR OVERPRESSURE PROTECTION. Dr. Angela E. Summers, PE. SIS-TECH Solutions, LLC Houston, TX

What is CFSE? What is a CFSE Endorsement?

Safety Integrity Level (SIL) Assessment as key element within the plant design

Basic Fundamentals Of Safety Instrumented Systems

Safety controls, alarms, and interlocks as IPLs

Guide to Selecting the Right PHA Documenting Software

Powerful information management services and software for the oil, gas, and chemical industries

SAFETY LIFE-CYCLE HOW TO IMPLEMENT A

A PROGRESSIVE RISK ASSESSMENT PROCESS FOR A TYPICAL CHEMICAL COMPANY: HOW TO AVOID THE RUSH TO QRA

Performance Based Gas Detection System Design for Hydrocarbon Storage Tank Systems

Singapore s Approach to Process Safety Management

SAFETY LIFECYCLE WORKBOOK FOR THE PROCESS INDUSTRY SECTOR

Process Safety Training (Shanghai)

On-Site Risk Management Audit Checklist for Program Level 3 Process

Process Safety Management Training

1997 CCPS Conference and Workshop Proceedings Layer of Protection Analysis: A New PHA Tool After HAZOP, Before Fault Tree Analysis

Alarm Management Standards Are You Taking Them Seriously?

Brochure. Hazard identification and risk assessment For the hazardous process industries

Controlling Risks Risk Assessment

Obsolescence Management for Industrial Assets. Don Ogwude President Creative Systems International

Understanding Safety Integrity Levels (SIL) and its Effects for Field Instruments

Risk Matrix as a Tool for Risk Assessment in the Chemical Process Industry

TÜV Rheinland Functional Safety Engineer Certificate (Process Hazard & Risk Analysis)

The Locomotive. Risk-Informed Fire Protection

A PROCESS ENGINEERING VIEW OF SAFE AUTOMATION

SCREENING FACILITIES FOR CYBER SECURITY RISK ANALYSIS. by Paul Baybutt Primatech Inc

Safety Assessment for a major hazard facility

July 30, AcuTech Group, Inc. Washington DC Houston Philadelphia San Francisco Dubai Shanghai

Practical Implementation of Safety Management Systems at Unregulated Upstream Oil & Gas Facilities

U.S. Chemical Safety and Hazard Investigation Board

TÜV FS Engineer Certification Course Being able to demonstrate competency is now an IEC requirement:

Defining and operationalizing the barrier concept

Alarm Philosophy Document Template. Prepared for: Customer Company Name

Occupational safety risk management in Australian mining

Guidance on Process Safety Performance Indicators

Planning Your Safety Instrumented System

Methods of Determining Safety Integrity Level (SIL) Requirements - Pros and Cons

GUIDELINES FOR THE CONDUCT OF OIL, GAS & PETROCHEMICAL RISK ENGINEERING SURVEYS

Roberts & Roberts Tel: (619) Adams Avenue Fax: (619) San Diego, CA 92115

AN ASSET-BASED APPROACH FOR INDUSTRIAL CYBER SECURITY VULNERABILITY ANALYSIS

Hazard Identification and Risk Assessment in Foundry

Guidance note. Risk Assessment. Core concepts. N GN0165 Revision 4 December 2012

The SPE Foundation through member donations and a contribution from Offshore Europe

Mitigating safety risk and maintaining operational reliability

Process Safety Management of Highly Hazardous & Explosive Chemicals. Management of Change

ARE YOU IN COMPLIANCE WITH THE OSHA COMBUSTIBLE DUST DIRECTIVE? Revised March 18, 2009

Double Jeopardy for $1000 Alex - What It Is and How to Apply It

Controlling fire and explosion risks in the workplace

Consequence Analysis: Comparison of Methodologies under API Standard and Commercial Software

Emergency Preparedness Guidelines

DEVELOPMENT OF A RISK ASSESSMENT PROGRAM AGAINST TERRORISM IN REPUBLIC KOREA

Is your current safety system compliant to today's safety standard?

Control measures for a major hazard facility

Static Spark Ignites Flammable Liquid during Portable Tank Filling Operation

Frost & Sullivan. Publisher Sample

Integrated Fire and Gas Solution - Improves Plant Safety and Business Performance

Safety Requirements Specification Guideline

TÜV Rheinland Functional Safety Program Functional Safety Engineer Certification

WELLHEAD FLOWLINE PRESSURE PROTECTION USING HIGH INTEGRITY PROTECTIVE SYSTEMS (HIPS)

Process Safety & Barrier Management. Lessons from major hazard industries

School of Engineering

PROCESS SAFETY CENTER

PTP-Global. Alarm Management An Introduction

EPA RISK MANAGEMENT PROGRAM RULE TO IMPACT DISTRIBUTORS AND MANUFACTURERS

ISMS Implementation Guide

To Mary Kay O'Connor Process Safety Center Home Page To Program details for Day 1 To Program details for Day 2

Gas Standards and Safety. Guidance Note GAS INSTALLATIONS SUPPLIED FROM BIOGAS FACILITIES - ACCEPTANCE REQUIREMENTS GAS ACT 2000

Failure Analysis Methods What, Why and How. MEEG 466 Special Topics in Design Jim Glancey Spring, 2006

EMP OF VIDYUT NAGAR GRAHA NIRMAN SAHAKARI SAMITI MARYADIT, GWALIOR

1 What is the purpose of this document?

TRAINING COURSE BROCHURE 2013

Version: 1.0 Last Edited: Guideline

Why Process Safety Management Audits Fail?

How To Improve Process Safety In Singapore

While determined risk is generally well understood, tolerable risk can be the missing link to complete risk assessments

Sample RMP/PSM Filing And Document Control/Circulation Policy

Hazard and Risk Assessment

FIRE RISK ASSESSMENT IN GERMANY - PROCEDURE, DATA, RESULTS -

Practical Examples of Fire Protection Engineering Practices and Technology for PSM

3.0 Risk Assessment and Analysis Techniques and Tools

DEVELOPING KPIS THAT DRIVE PROCESS SAFETY IMPROVEMENT

Vishesh Diagnostics Pvt. Ltd. EMP

Prescriptive and risk based SIL allocation methods used together

Alarm Management What, Why, Who and How?

Process Safety Management

Do you speak SAFETY?

IMPLEMENTATION OF PROCESS SAFETY MANAGEMENT (PSM) IN CAPITAL PROJECTS

DeltaV SIS for Burner Management Systems

Risktec Training Catalogue 2016

The Unintentional Insider Risk in United States and German Organizations

Electrical Safety in the Marine Environment

Our Know-How. Your Peace of Mind. Innovative Sealing and Gasket Solutions

All Oil and Gas Companies under the Jurisdiction of the National Energy Board (the Board or NEB) and All Interested Parties

Workplace Injuries and Illnesses Safety (WIIS) Report

Transcription:

FAQ SHEET - LAYERS OF PROTETION ANALYSIS (LOPA) Acronyms and Abbreviations Used ANSI - American National Standards Institute IPL - Independent Protection Layer ISA - The Instrumentation, Systems and Automation Society LOPA - Layers of Protection Analysis PHA - Process Hazard Analysis QRA - Quantitative Risk Analysis SIS - Safety Instrumented System What is LOPA? It is a simplified risk assessment method. It provides a method for evaluating the risk of hazard scenarios and comparing it with risk tolerance criteria to decide if existing safeguards are adequate, and whether additional safeguards are needed. Various LOPA methods are available. LOPA does not suggest which safeguards to add or which design to choose but it does assist in deciding between alternatives. LOPA can be viewed as an extension of Process Hazard Analysis (PHA). Typically, it is applied after a PHA has been performed. LOPA builds on the information developed in the PHA. Why was LOPA developed? Subjective engineering judgement is used to identify the need for additional safeguards in process hazard analysis. This can lead to disagreements and possibly the implementation of inappropriate measures to reduce risk. It was recognized that a more rational and objective approach was needed. an you tell me more about layers of protection? Process designers use a variety of protection layers, or safeguards, to provide a defense in depth against catastrophic accidents. They are devices, systems or actions that are capable of preventing a scenario from proceeding to an undesired consequence. For example, they may be: 1 opyright 2005, Primatech Inc. All rights reserved

Inherently safe design features Physical protection such as relief devices Post-release physical protection such as fire suppression systems Plant and community emergency response Safety Instrumented Systems (SIS) Ideally such protection layers should be independent from one another so that any one will perform its function regardless of the action or failure of any other protection layer or the initiating event. When they meet this criterion they are called Independent Protection Layers (IPL). Not all safeguards meet the independence requirements to be classified as an IPL, although all IPLs are safeguards. For example, two standby pumps that are both electrically powered do not fail independently in the event of loss of power. LOPA addresses safeguards that are IPLs. Such safeguards include SIS, also called interlocks and emergency shutdown systems. SIS are addressed by the standard ANSI/ISA S84.00.01-2004, Functional Safety: Safety Instrumented Systems for the Process Industry Sector, called S84 herein, which can include the use of LOPA. What is involved in LOPA? Individual hazard scenarios defined by cause-consequence pairs are analyzed. Scenario risk is determined by combining scenario frequency and consequence severity. Individual protection layers are analyzed for their effectiveness and the combined effects of the protection layers are compared against risk tolerance criteria to determine if additional risk reduction is required to reach a tolerable level. Scenario frequency is determined by combining initiating event frequency, IPL failure probabilities and the probabilities of enabling events/conditions and conditional modifiers. Enabling events or conditions do not directly cause the scenario but must be present or active for the scenario to proceed, for example, the process being in a particular mode or phase. ommonly considered conditional modifiers are the probability that released flammable/explosive material will ignite, the probability that an individual will be present to be exposed to a hazard, and the probability than an exposed individual will actually be impacted. Order of magnitude estimates are used for frequencies, probabilities and consequence severity. 2 opyright 2005, Primatech Inc. All rights reserved

How do risk tolerance criteria help? Without risk tolerance criteria, there is a tendency to keep adding safeguards in the belief that the more added, the safer the process. This can be a false assumption. Eventually safeguards will be added that are unnecessary. This reduces the focus on safeguards that are critical to achieving tolerable risk. Unnecessary safeguards also add complexity that may result in new, unidentified hazard scenarios. LOPA helps focus limited resources on the most critical safeguards. How does LOPA relate to Quantitative Risk Analysis (QRA)? LOPA adds simplifying assumptions for the numerical information used. The simplifications are intended to be conservative so that QRA would show less risk for a scenario than LOPA. How should I conduct PHA s to facilitate LOPA? LOPA studies will be easier to conduct if the following issues are addressed during the PHA: larify initiating events, i.e. causes of hazard scenarios Provide sufficient scenario detail Express consequences in a form compatible with LOPA Record and identify candidate IPLs, i.e. safeguards List all safeguards before deciding if they are IPLs onsider identifying enabling events/conditions and conditional events Rank hazard scenarios so they can be screened for LOPA Flag recommendations for additional IPLs 3 opyright 2005, Primatech Inc. All rights reserved

Are there other applications of LOPA? Yes. It can be extended to many situations involving risk-informed decision making including: Design apital improvement planning Management of change Evaluating facility siting risk Mechanical integrity programs Identifying operator roles Incident investigation Emergency response planning Bypassing a safety system Determining the design basis for over-pressure protection Determining the need for emergency isolation valves Screening tool for QRA an you summarize what LOPA does and doesn t do? There are three issues for protection layers: How safe is safe enough? How many protection layers are needed? How much risk reduction should each layer provide? Risk tolerance criteria must be established for LOPA and they address the first issue. LOPA helps decide how much risk reduction is needed and how many protection layers should be used. It does not help decide what specific IPLs should be used. 4 opyright 2005, Primatech Inc. All rights reserved

Why should I perform LOPA? Provides an objective, rational and defensible basis for recommendations to install or not install safeguards after a PHA has been performed. Meets the requirements of the S84 standard for SIS. Note that OSHA expects compliance with S84. Provides the basis for a clear, functional specification for safety instrumented systems. How can I get more information? ontact Primatech at: 50 Northwoods Blvd. olumbus, OH 43235 Tel 614-841-9800 Fax 614-841-9805 5 opyright 2005, Primatech Inc. All rights reserved

About Primatech Primatech specializes in Process Safety, Security and Risk Management. We offer consulting, training and software (e.g., HAZOP Software - PHAWorks and tracking software - Tracker) to assist our clients in identifying and reducing the risks posed by hazardous materials. ompanies in a variety of industries choose Primatech to help them manage their risks. We help companies reduce the likelihood and consequences of releases, which helps protect employees and the public and prevent damage to equipment and the environment. Reducing these risks also improves productivity and quality. We help companies comply with the OSHA Process Safety Management (PSM) standard, EPA Risk Management Program (RMP), and other industry guidelines and requirements. Our capabilities include: Process Hazard Analysis (PHA), e.g., HAZOP Studies Security Vulnerability Analysis for Deliberate Acts Including Terrorism ompliance Audits and Program Assessments PSM Program Development and Implementation RMP Program Development and Implementation yber Security Management Release and Spill Assessment Process Security Management S84 - Safety Instrumented Systems Layers of Protection Analysis (LOPA) Operating and Maintenance Procedures Development Mechanical Integrity Program Development and Implementation Guidance Human Factors and Human Error Analysis Facility Siting Analysis Dispersion and onsequence Modeling Probability Modeling Quantitative Risk Assessment Emergency Response Program Development and Implementation Guidance Expert Witness Testimony and Litigation Support Primatech clients are often Fortune 500 companies but also include medium and smaller sized companies. We specialize in serving the process industries, and have served hundreds of industrial facilities throughout the world. Primatech projects have spanned a wide range of industries including: Aerospace Agricultural hemicals Bulk ommodity hemicals old Storage Warehousing Electronics Food Processing Hazardous Waste Treatment Inorganic hemicals Mining Oil & Gas Production and Distribution Oil & Gas Pipelines and Terminals Organic hemicals Paints, oatings, Resins & Adhesives Petroleum Refining Pharmaceuticals Polymers and Resins Propane Storage & Distribution Pulp & Paper Rubber and Plastics Semiconductors Steel Water & Wastewater Treatment Our services and products enable our clients to achieve their risk, safety and security objectives faster and easier. Primatech is an independent company with no vested interests and is seen, therefore, to deliver work recognized as objective and unbiased. opyright 2005, Primatech Inc. All rights reserved