A Guide for Documenting the Management System for a Testing/Calibration Lab. May 2015



Similar documents
NABL NATIONAL ACCREDITATION

TITLE: Quality System Manual DOCUMENT NUMBER: QMS

American Association for Laboratory Accreditation

Quality Management System Policy Manual

THERMAL INSULATION MATERIALS

NIST HANDBOOK 150 CHECKLIST

EA IAF/ILAC Guidance. on the Application of ISO/IEC 17020:1998

Luminus Devices, Inc Luminus Testing Laboratory Quality Management Systems Manual

ISO/IEC QUALITY MANUAL

Non-Controlled Copy. Quality Manual Revision Log. Rev # Date Description

NIST HANDBOOK CHECKLIST CONSTRUCTION MATERIALS TESTING

State Meat and Poultry Inspection (MPI) Program Laboratory Quality Management System Checklist

Testing Facility Laboratory Manual

QUALITY MANUAL GREAT LAKES INSTITUTE FOR ENVIRONMENTAL RESEARCH ANALYTICAL LABORATORIES. October 2008 Revision 08

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

R103 - GENERAL REQUIREMENTS: PROFICIENCY TESTING FOR ISO/IEC LABORATORIES

1 For more information T: / E: DAP@ul.com / W: ul.com/dap

Gap Analysis of ISO 15189:2012 and ISO 15189:2007 in the field of Medical Testing

American Association for Laboratory Accreditation

Analytical Laboratories, Inc.

South Coast Air Quality Management District

OD-2017-Ed.1.5 CHECK LIST FOR TESTING AND CALIBRATION LABORATORIES

Recognition of my Product (Testing Laboratory) Why I need recognition, what is the effect?

EA-7/01. EA Guidelines. on the application. Of EN Publication Reference PURPOSE

Company Quality Manual Document No. QM Rev 0. 0 John Rickey Initial Release. Controlled Copy Stamp. authorized signature

NABL accreditation is a formal recognition of the technical competence of a medical testing laboratory

EPA NATIONAL LEAD LABORATORY ACCREDITATION PROGRAM. LABORATORY QUALITY SYSTEM REQUIREMENTS (LQSR) REVISION 3.0 (November 05, 2007)

Quality Procedures and Work Instructions Manual

Quality Manual ALABAMA RESEARCH & DEVELOPMENT. This Quality Manual complies with the Requirements of ISO 9001:2008.

CHECKLIST ISO/IEC 17021:2011 Conformity Assessment Requirements for Bodies Providing Audit and Certification of Management Systems

CORPORATE QUALITY MANUAL

Eagle Machining, Inc. Quality Management System

Quality Manual. This Quality Manual complies with the Requirements of ISO 9001:2008 and ISO/IEC , Explosive Atmospheres - Edition 1.

Steps to ISO/IEC Accreditation

IAS CALIBRATION and TESTING LABORATORY ACCREDITATION PROGRAMS DEFINITIONS

ISO 9001:2008 Quality Management System Requirements (Third Revision)

FSSC Q. Certification module for food quality in compliance with ISO 9001:2008. Quality module REQUIREMENTS

Quality Assurance (QA) & Quality Control (QC)

Quality Assurance Manual January 2008 Revision I Revision date of 01/17/13. Pi Tape Corporation. 344 North Vinewood St. Escondido CA USA

ISO 9001:2000 Gap Analysis Checklist

QUALITY OPERATING PROCEDURE QOP QUALITY ASSURANCE SYSTEM MANUAL

QUALITY MANAGEMENT SYSTEM REQUIREMENTS General Requirements. Documentation Requirements. General. Quality Manual. Control of Documents

Internal Audit Standards

Copyright, Language, and Version Notice The official language of this [Certification Protocol] is English. The current version of the [Certification

ISO 9001: 2008 Construction Quality Management System Sample - Selected pages (not a complete plan)

Quality Manual. UK Wide Security Solutions Ltd. 1 QM-001 Quality Manual Issue 1. January 1, 2011

Section i POLICY AND AUTHORITY STATEMENT

CP14 ISSUE 5 DATED 1 st OCTOBER 2015 BINDT Audit Procedure Conformity Assessment and Certification/Verification of Management Systems

ISO 9001:2008 Audit Checklist

National Information Assurance Partnership /Common Criteria Evaluation and Validation Scheme. Publication #2

P07 CALA Application of Requirements in ISO/IEC 17025:2005 Revision 3.4 April 9, 2014

QUALITY ASSURANCE MANUAL JPM OF MISSISSIPPI, INC.

Implementing an Energy Management System Using ISO 50001

ALACC Frequently Asked Questions (FAQs)

ISO-9001:2000 Quality Management Systems

Network Certification Body

Revision Date Author Description of change Jun13 Mark Benton Removed Admin. Manager from approval

EffiValidation 3.0 software basic training module

Checklist. Standard for Medical Laboratory

ED FAGAN INC. QUALITY SYSTEM MANUAL

CENTRIS CONSULTING. Quality Control Manual

Application of ISO/IEC for the Accreditation of Food Safety Management Systems (FSMS) Certification Bodies

Quality management systems

Surgi Manufacturing Quality Manual

GENERAL REQUIREMENTS FOR THE PROGRAMME OF REFERENCE MATERIAL CERTIFICATION IN SERIAL PRODUCTION

Control No: QQM-02 Title: Quality Management Systems Manual Revision 10 07/08/2010 ISO 9001:2008 Page: 1 of 22

The President of Inductors Inc. is the senior executive responsible for operations.

How DCMA Helps To Ensure Good Measurements

EDUCATION AND TRAINING OF THE LABORATORY STAFF AS A PART OF THE LABORATORY COMPETENCE

ISO 9001 : 2000 Quality Management Systems Requirements

ISO 9001:2000 AUDIT CHECKLIST

Quality Management System Manual

HONG KONG ENVIRONMENTAL ELECTRICAL APPLIANCE COMPANY. Environmental Procedure

Micro Plastics, Inc. Quality Manual

DHI DANETV Test Centre Quality Manual

NVLAP Assessor Training

Quality Management Systems Manual

ISO/IEC Inspection Standard Application Document

AEROSPACE STANDARD. Quality Management Systems - Requirements for Aviation, Space and Defense Organizations RATIONALE

rtech laboratories began working toward ISO 9002:1994 in ISO 17025: Practical Benefits of Implementing a Quality System STATISTICAL ANALYSIS

Document Control. White Paper By Galaxy Consulting. At Your Service Today Tomorrow We Appreciate The Privilege Of Serving You! Abstract.

CRITERIA FOR PERFORMING CALIBRATION AND INTERMEDIATE CHECKS ON EQUIPMENT USED IN ACCREDITED FACILITIES

ISO 9001 Quality Systems Manual

FSSC Certification scheme for food safety systems in compliance with ISO 22000: 2005 and technical specifications for sector PRPs PART II

Appendix 3 (normative) High level structure, identical core text, common terms and core definitions

Disclosure to Promote the Right To Information

Medical Cannabis Laboratory Approval Program

JOHN HART GENERATING STATION REPLACEMENT PROJECT. Schedule 9. Quality Management

Standard Practice for Quality Control Systems for Nondestructive Testing Agencies 1

NC SBI QUALITY ASSURANCE PROGRAM

P-01 Certification Procedure for QMS, EMS, EnMS & OHSAS. Procedure. Application, Audit and Certification

MP Plumbing & Heating Ltd Quality Policy Manual THE QUALITY POLICY STATEMENT OF:

INTERNATIONAL STANDARDS FOR THE PROFESSIONAL PRACTICE OF INTERNAL AUDITING (STANDARDS)

The Prophotonix (UK) Ltd Quality manual

COMPANY NAME. Environmental Management System Manual

REQUIREMENTS FOR AN ACCREDITED VETERINARY MEDICAL DIAGNOSTIC LABORATORY

Quality Assurance QUALITY ASSURANCE PLAN

Transcription:

A Guide for Documenting the Management System for a Testing/Calibration Lab May 2015 1. Introduction The following guide is to help testing/calibration laboratories create documentation to satisfy the requirements of ISO 17025. Such documentation is a necessity for accreditation by IAS and is the first step to be taken by a laboratory in its march towards public recognition of its competence in the testing/calibration disciplines. Accreditation by IAS, recognized the world over because of its Mutual Recognition Arrangements with APLAC/ILAC, helps laboratories enhance their business opportunities both inside and outside the U.S. 2. Structure of the Documentation A management system serves as a working document for the entire operation of a testing/calibration laboratory. Its application to day-to-day work results in uniformity, consistency and quality improvement in the operations of the laboratory. This document gives broad guidelines. The operational details will depend upon the size/activities of the laboratory. Generally, laboratories need two levels of documentation. A management system manual describing the laboratory s policies and objectives and a procedures manual, should be sufficient for a small or medium sized laboratory, although laboratories are free to adopt several levels of documentation if their operations are large enough to justify extensive documentation. 3. General Advice a) Make a start. Do not get scared. Do not procrastinate. Remember, even a thousand-mile journey starts with the first step. b) Go through the 17025 Standard. If you feel sleepy while reading, take a nap. But continue never give up. Much harder tasks have been completed in this world. c) As you go through the standard, concentrate on, contemplate and comprehend each clause. Try to understand what the standard requires for your operation. d) If your laboratory has been functioning for a while, some kind of management system must already be in place. Maybe just some modification, some reorientation, some refinement is needed. Try to fine-tune the system that you already have. e) The management system is generally written by a senior level person, and needs the approval of the quality manager. Sometimes, the same person will wear both hats. Either way is okay. Page 1 of 8

f) It is better if the procedural manuals are written by the personnel performing the actual technical procedures, then edited/fine-tuned by senior personnel and the quality manager. g) Write the manual in the present tense and do not use shall or will in the manual. Use is and are extensively. Never copy lines from the 17025 Standard into the manual. h) Use simple, concise and grammatically correct language. Get to the point of the 17025 clauses. Avoid wordiness and unnecessary language. i) As far as possible, set up your manual so that the clauses and subclauses follow the same sequence as the 17025 Standard. This is not mandatory but makes the manual more user-friendly. If, for some compelling reason, the sequence of clauses cannot be followed, provide a cross-reference table (listing all the clauses and subclauses) at the end of the manual. j) Address each clause/subclause of the standard briefly in the manual. If you need to spell out too much detail, make a separate numbered document and refer to the document number in the manual. k) Use double spacing. l) Make the following part of the management system manual: i. A title page giving both the physical and electronic addresses of your organization/laboratory. ii. An authorization from the CEO for a particular person, by name and designation, to function as the quality manager, having the overall responsibility for establishing, implementing and maintaining the laboratory s management system. iii. A page providing the issue details of the manual revision number, issue number, date of issue, copy number, copy holder, and status (controlled or uncontrolled), etc. iv. An amendment record providing, in tabular form, information on changes to the manual: clause number, date of the amendment, nature of the change, brief reason for the amendment, person approving the change, etc. m) Start each clause/subclause on a new page. This will be of great help, in the future, if you need to amend or add pages to address the clause/subclause. Also, in numbering pages, bunch together the pages for each clause/subclause, and number the pages in the fashion page of Leave a couple of pages blank at the end of each clause and mark the blank pages Intentionally Left Blank. Include these blank sheets in the numbering of the pages. These blank sheets will be of help, in future, if there is a need for some amendment requiring additional space. By paginating in this way, you will be able to amend individual clauses without changing the entire manual, and introducing amendments will be much easier and faster. This also makes document control easier. n) Use the same format for all pages of the manual. Text should appear on only one side of the page. The page format should include the company name, its logo (if there is one), the clause number which the page addresses, the manual revision number, issue number, the date of issue, the page number, and signatures of persons who prepared the manual and who approved the manual. A typical format is shown below: Page 2 of 8

Company Logo Management Manual Of Revision Number Issue No. & Date 4. Management System Page No. of Company s Name and Address Copy Status: Prepared by: Signature (Name) Approved by: Signature (Name) This manual is the property of ; No corrections/amendments are to be made except by the person authorized. The holder to return the manual when he leaves the organization or when he has no further use for it. Page 3 of 8

o) Once the manual is ready, make one Master Copy. The master copy must at all times be resident with the quality manager, who should make copies and distribute after stamping (for example) Controlled When in Red or Uncontrolled. Remember to send only uncontrolled copies to outside assessors or accrediting bodies. p) Any amendment should be made only on the Master Copy with copies then made for distribution to persons holding the manual. q) If manuals/documents are maintained electronically, they should be controlled through password, Read only means. 4. Now about the Actual Documentation Read and understand how the clauses apply to the activities in your organization. Get both macro and micro picture of the activities. Read the first clause. Understand what needs to be addressed. Close the standard. Ponder again and get a clear picture. Write down, in your own words, how you would address the clause. Come directly to the point (no unnecessary wording). Keep your organization s activities focused in your mind while you write. Continue in a similar way for other clauses. 5. Use the first three clauses of the manual to introduce your organization and its vision, and the activities of the laboratory in some detail. 6. Address each clause/subclause/sub-sub-clause, even if it does not apply to your laboratory s activities and give a reason for its nonrelevance. For example, if sampling (clause 5.7) does not apply to your laboratory (generally, it does not apply to calibration activities), make some statement such as this: Since the laboratory calibrates every instrument it receives and does not resort to sampling practice, this clause does not apply. In such a case, the subclauses would not need to be addressed. 7. Organization Provide a complete but brief description of the organization. Provide details of the laboratory organization down to the technician/operator level. Show the direct link of the Quality Manger to top management. Address impartiality, integrity, confidentiality and client s rights clauses. Include the responsibility of staff to follow documented policies and procedures. Make a statement that any deviation from documented policies and procedures should be first endorsed by the senior management in charge of quality before the deviation takes place. Assign deputies for the Quality Manager and key technical staff. Include duties and responsibilities of the Quality Manager and the technical staff of the laboratory. 8. Management System Briefly describe the management system and its aims and objectives. Quality Policy: This must be a statement from top management, endorsed by the CEO of the organization. Avoid use of superlatives in the statement. Include intended quality of Page 4 of 8

service, activities complying with 17025, staff familiarizing themselves with policy, commitment to staff training, and continuous improvement. Remember, every word of the policy statement is auditable. Carefully choose words and KISS (Keep It Short and Sharp). Preferably, the quality statement should not be more than a page. 9. Document Control Know the difference between documents and records. Documents are distributed/made known to the personnel of the laboratory, to be understood and followed. Records are data/information generated by the personnel during the course of following the instructions in a document. While quality manuals, procedure manuals, instructional manuals, normative standards, policy documents, test/calibration methods, etc., are documents, calibration/test results, nonconformance s observed and reported, audit findings, management review minutes, etc., are records. Make a document distribution list a part of the manual under this clause. A typical table would be as below: No. Copy No. Copy Holder Copy Status 1 Master Copy Quality Manager - 2 01 CEO Controlled 3 02 Quality Manager Controlled - 03 Lab-incharge/Supervisor Controlled - - - - - - - - n 06 Accreditation Body Assessor Uncontrolled Maintain an issue register with signatures of recipients. The Quality Manager can sign for the documents sent to accreditation bodies and assessors. Make the Quality Manager responsible for controlling and maintaining all the documents related to the management system. Control should include distribution, distribution of amendments, approval and incorporation of amendments, and removal of obsolete documents and their disposal. 10. Review of Requests, Tenders and Controls More popularly known as contract review, this clause is an important one. It aims at greatly reducing (or almost eliminating) any disputes that might arise between customers and the laboratory, after the test/calibration is over. It is intended to link what the customer expects the laboratory to do and what the lab actually does, so there is no discrepancy between customer-expectation and laboratory delivery. For example, if a customer submits a sample to be tested using a standardized procedure (say ASTM ), and the laboratory, for some reason, intends to deviate from the procedure, the customer must be informed of the deviation and his consent obtained, before the work is started. The deviation and the customer acceptance have to be documented. Page 5 of 8

Make statements about understanding the client s requirements, having available the required resources (personnel, equipment, reference standards, analysis capabilities, time, etc.) to handle the work, documentation of the contract review, etc. 11. Purchasing Address purchase of services for calibration of the laboratory s equipment from an NMI or another accredited laboratory. Address purchase of calibration equipment and critical consumables, if any. 12. Complaints Maintain a register of complaints. The register should provide information about the date the complaint was received, the nature of the complaint, how it was resolved, etc. Address working with the customer (to assure continued business) in the case of valid complaints. 13. Nonconformances, Corrective Actions, Cause Analysis Address stoppage of work when a nonconformance is observed. As regards the nonconformance, address evaluation of significance, cause analysis, development of corrective action, corrective action implementation, and resumption of work under authorization. Address the responsibility of the person authorizing resumption of work. 14. Internal Audits Address the frequency (at least once a year) and scope of audits. Address auditor selection (qualifications/experience/training), responsibility for auditor selection (usually Quality Manager), audit procedures, audit review, and corrective actions. 15. Management Reviews Address all ten elements of the clause. A management review meeting is to be held within a reasonable time after every internal/external audit. 16. Personnel State the minimum qualifications/experience of technical personnel handling testing/calibration work. Address supervision of work. Prepare an Authorized Signatories list of the persons who can approve release of reports. Address programs aimed at improving employees skills, such as education programs, training, hands-on training. Identify the responsibilities of technical personnel, supervisory personnel. For all personnel, keep records of academic qualifications, experience, professional qualifications, training programs attended, special skills, certificates acquired for special skills, etc. Address adequacy of supervision by stating the ratio of supervisors to technical personnel. 17. Accommodation and Environment State the environmental conditions maintained in the laboratory. [The environmental conditions are more stringent if yours is a dimensional calibration laboratory. For a Page 6 of 8

dimensional calibration laboratory, the base temperature should be 20 C (68 F) with a tolerance of 1 to 3 C (2 to 5.5 F) depending on the level of operation. Humidity should be around 50 ± 5% RH, and the room should be at a positive pressure.] Give layout of the lab in a sketch indicating the position of each piece of major equipment. Provide information about the area of the laboratory. Describe controls on access to the laboratory. Describe the procedures used to monitor and document environmental conditions. (If it is a dimensional calibration lab, state the frequency at which the temperature is monitored and recorded.) Address cleanliness and good housekeeping. 18. Test and Calibration Methods Refer to methods briefly in the management system manual and address in detail in procedures/work instructions. Write procedures for all the testing/calibration done by the laboratory. Include handling and preparation of materials for test/calibration. For nonstandard methods, address validation. 19. Uncertainty of Measurement Provide a procedure as a separate document, and briefly explain the procedure in the manual. In the procedure, provide information about all the factors considered for type B method adopted for type A values, and provide a step-by-step evaluation process. Provide an uncertainty evaluation format for each family of instruments. 20. Control of Data Address procedures for error-free data transfer. Address software access and control through passwords. Address software validation. 21. Equipment Provide a list of major equipment, including name, identification number, range, resolution, uncertainty, frequency of calibration, traceability. Address maintenance, availability of instruction manuals, history cards, etc. 22. Traceability State how the laboratory s measurements are traceable to the national level. 23. Calibration State usage of SI units and how work in non-si units is handled to provide traceability. 24. Reference Standards Provide a list of physical reference standards maintained by the laboratory (if applicable), and provide similar information to that listed under item 21 above. 25. Assuring Quality of Test and Calibration Results Address use of physical reference standards, calibration of standards by an NMI, calibration of standards by an accredited laboratory, traceability, periodic recalibration, proficiency testing, interlaboratory comparisons, replicate checking and reproducibility. Page 7 of 8

26. Reports State the contents of testing/calibration reports. Provide a format for each of them. Address how reporting is handled if testing/calibration is subcontracted. Provide a list of authorized signatories, including name, title and sample signature. Address amendments to a report. Address supplements to a report. In the format, provide for disclaimer clauses such as: (1) This report pertains to the item supplied and the stated conditions of testing/calibration; (2) This report should not be reproduced except in full. 27. Opinions and Interpretations Address the conditions under which opinions/interpretations are given, and also the basis on which they are given. 28. Results from Subcontractor State that the results from a subcontractor will be clearly identified in the test/calibration report. 29. Electronic Transmission of Results State that electronic transmission (by fax or e-mail) is provided when specifically requested by the customer. State that even if reports are electronically transmitted, a hard copy will eventually follow, and that any disputes should involve the values in the hard copy. 30. Conclusion State that all efforts will be made to provide the results of testing/calibration with honesty and integrity and without any bias. State that all efforts have been made to present the facts in the manual, and that any questionable items will be attended to as soon as they are noticed, by amendments or rewriting. Page 8 of 8