GENERAL ELECTRICAL REQUIREMENTS



Similar documents
GENERAL WIRING RULES FOR HOUSES

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

A TO Z HOME INSPECTIONS PROFESSIONAL HOME INSPECTION SERVICES FOR HOME BUYERS AND SELLERS

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

Electrical Code Regulation

ELECTRICAL REQUIREMENTS Specific Information for Electrical Work Installers

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

Residential Electrical Inspection. Checklist

Residential Electrical Inspection Checklist

Residential Electrical Inspection. Checklist

INSPECTION GUDELINES

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Electrical Installations A homeowner guide to the Winnipeg Electrical By-law requirements for a Single Family Dwelling, Detached Garage or Shed.

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/20/2009)

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

Electrical Wiring Guide

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

2. What building projects are exempted? (permit not required)

HomeOwner Wiring. Please remember you are required to contact your inspector for inspections

CITY OF FAIRFAX CODE ADMINISTRATION / FAX

SWF Home Inspections

ADOPTION OF THE NATIONAL ELECTRICAL CODE, 2005

Typical Finished Basement Details

Questions and Answers for Heating and A/C Contractors

Uniform Construction Code (UCC) Building Permit Application Package

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

Inspecton Report. Property Address:

Residential Wiring Guide 12th Edition

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

Home Inspection Report

How To Build A Basement House

BUILDING PERMIT SPECIFICATIONS

Development Services City of Lawrence, KS

FINISHED BASEMENT REQUIREMENT GUIDE

CERTIFICATE OF COMPLIANCE

**ATTENTION** WE DO NOT PROMOTE OR ENCOURAGE YOU TO DO YOUR OWN ELECTRICAL WIRING!!! IT IS BY FAR THE MOST DANGEROUS THING YOU CAN ATTEMPT

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

Typical Finished Basement Details

Homeowner Information Guide Electrical Safety. British Columbia Safety Authority

Vari Inspection Services

EXPRESS PERMITS (No Plan Check Required)

Inspection Report Atlanta Strip Mall Commercial Building Property Address:

Georgia Association of Home Inspectors

How To Make A House Safe

FINISHED BASEMENT SUBMITTAL GUIDE

COMPREHENSIVE PROPERTY INSPECTIONS

October 5, 2015 Dear Client,

City of St. Charles Basement Finish or Remodel

Direct Inspections - Tel: (941) Michael@DirectInspections.com -

Residential Code Requirements

Propery Inspection Report

Ref NFPA 501 reference 3280 reference as shown with changes Current wording of

PALM BEACH COUNTY AMENDMENTS TO THE NATIONAL ELECTRICAL CODE, 1999 EDITION

SPECIAL GUIDELINES FOR ELECTRICAL INSTALLATION

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

City of Riverside Building & Safety Division Residential Electric Vehicle (EV) Charger Guidelines

Inspection Tech. (330) Inspected By: Aaron Westerburg

ELECTRICAL INFORMATION

Building Condition Assessment Report

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

Quality Home Inspections, LLC 4433 Tennyson Street Denver, Colorado

Irvinton Village Apartments 2901 Fulton Houston, Texas Houston Housing Authority J. Allen Management Managing Agent

2 electrical. electrical PulteGroup, Inc. All Rights Reserved.

Pre-Drywall Inspection Report

Inspection Report. Prepared for: William Smith 2700 New Street Plano, TX 75025

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS

RHODE ISLAND DIVISION OF STATE FIRE MARSHAL

DEPARTMENT OF ECONOMIC AND COMMUNITY DEVELOPMENT, BUILDING DIVISION TH Street Daly City CA (650)

I NI NP R Inspected Items

HV AC CODE CHECKLISTS

HOMEOWNER S PERMIT GUIDE

Holz Choices & Specifications

Electrical Contractors. and the. New Jersey. Rehabilitation Code

County of Riverside Building and Safety Department

CHRIS CURLES and ASSOCIATES INSPECTION SERVICES

Johnson County Kansas Unincorporated

The purpose of this document is to provide standards for persons requesting or subject to County building inspections.

COST OF WORK FORM. Abbreviations: ea = each, LF = linear feet, SF = square feet, HSF = square feet of living area (including garage conversion space)

Chapter 9. Bonding and Grounding

Single Family Residential Basement Finish

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Electrical Safety Plugs What are the different types of plugs? Extension Cords What are some potential hazards involving extension cords?

Code Enforcement Inspection Manual. City of Virginia Beach Department of Housing and Neighborhood Preservation Code Enforcement Division

City of Riverside Building & Safety Division Phone: (951)

MONTGOMERY COUNTY EXECUTIVE REGULATION Offices of the County Executive. 101 Monroe Street. Rockville, Maryland 20850

EAST STROUDSBURG BOROUGH RESIDENTIAL RENTAL INSPECTION CHECK LIST

INSIDE TELEPHONE WIRING FOR Business

Crawford Inspection Services C.C.B. #

RRIO Checklist. Use of checklist: Definitions: Limitations

Smoke & Carbon Monoxide

Schedule of Maintenance Fees

Building Permits: When are they required?

Inspection Report. Prepared For: Sampath Sample. Property Address: Waterside Drive. Alpharetta, GA Atlanta Home Inspections

Entrances to and from Electrical Equipment Rooms

Orlando Home Inspection Services

Significant Changes in the 2011 NEC Prepared by Bryan Holland City of North Port

BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER

Transcription:

GENERAL ELECTRICAL REQUIREMENTS RECEPTACLE SPACING Within 6-feet of the edge of any door HABITABLE Not more than 12-feet apart along wall ROOMS: At all wall spaces 24 or more wide Within 24 of edge of sink, range, refrigerator, and end of counter Not more than 4-feet apart along counter top At all counter spaces 12 or more wide KITCHEN: At all kitchen island counter spaces At all kitchen peninsula countertops Not more than 20 above countertops BATHROOM: Within 3-feet of each basin GARAGE: A minimum of 1 receptacle required in garage HALLWAY: 1 receptacle required for hallways 10-feet or more in length 1 receptacle required at the front and back of dwelling, located less than OUTDOOR: 6-1/2 feet above grade H. V. A. C. 1 receptacle within 25-feet on air conditioning unit. KITCHEN: OUTDOOR: GARAGE: BATHROOM: WET BAR SINK: WORKSHOP: BEDROOM: AMPERAGE: DEDICATED: SIZE: DEDICATED: G. F. C. I. RECEPTACLES All kitchen countertop receptacles must be GFCI protected All outdoor receptacles must be GFCI protected All general purpose garage receptacle must be GFCI protected All bathroom receptacles must GFCI protected Receptacles within 6-feet of sink must be GFCI protected Receptacles in grade level workshop/storage buildings must be GFCI protected A. F. C. I. (ARC-FAULT) OUTLETS All bedroom/sleeping area outlets must be AFCI protected BATHROOM CIRCUIT Minimum of 1 20 amp circuit Circuit supplying more than one bathroom cannot supply any fan, light, or receptacle, other than the bathroom receptacle(s) WASHING MACHINE CIRCUIT 20-amp circuit Circuit cannot supply any light, receptacle, etc. other than washing machine receptacle KITCHEN CIRCUITS SIZE: 20-amp rating for all kitchen receptacle circuits. # OF CIRCUITS: Minimum of 2 20 amp circuits to supply kitchen

WIRE AND BREAKER SIZES RECEPTACLES / APPLIANCES CIRCUIT TYPE WIRE SIZE BREAKER SIZE General Purpose Outlets 12-2 with ground romex 20-amp 1-pole 14-2 with ground romex 15-amp 1-pole Kitchen Outlets 12-2 with ground romex 20-amp 1-pole Washing Machine 12-2 with ground romex 20-amp 1-pole Water Heater (4500 Watt) 10-2 with ground romex 30-amp 2-pole Water Heater (< 4500 Watt) 12-2 with ground romex 20-amp 1-pole Range 6-3 with ground romex 50-amp 2-pole Dryer 10-3 with ground romex 30-amp 2 pole HEAT / AIR CONDITIONING TYPE RATING WIRE SIZE BREAKER SIZE AIR HANDLER 7.5 KW 6-2 with ground romex 50-amp 2-pole AIR HANDLER 10 KW 6-2 with ground romex 60-amp 2-pole AIR HANDLER 15 KW 6-2 with ground romex 60-amp 2-pole 10-2 with ground romex 30-amp 2-pole AIR COND 3-TON 10-2 with ground romex 30-amp 2-pole AIR COND 3-1/2 TON 8-2 with ground romex 40-amp 2-pole AIR COND 4-TON 6-2 with ground romex 40-amp 2 pole AIR COND 5-TON 6-2 with ground romex 50-amp 2 pole WATER PUMP (COPPER WIRE) H. P. VOLTS WIRE LENGTH WIRE SIZE BREAKER 120 VOLT < 100 feet 10-2 with ground UF 20-amp 1/2 H. P. 3/4 H. P. 1 H. P. 120 VOLT 100 to 200 feet 8-2 with ground UF 20-amp 120 VOLT 200 to 300 feet 6-2 with ground UF 20-amp 240 VOLT < 100 feet 12-2 with ground UF 15-amp 240 VOLT 100 to 200 feet 12-2 with ground UF 15-amp 240 VOLT 200 to 300 feet 10-2 with ground UF 15-amp 120 VOLT < 100 feet 10-2 with ground UF 30-amp 120 VOLT 100 to 200 feet 6-2 with ground UF 30-amp 120 VOLT 200 to 300 feet #4 copper 30-amp 240 VOLT < 100 feet 12-2 with ground UF 20-amp 240 VOLT 100 to 200 feet 10-2 with ground UF 20-amp 240 VOLT 200 to 300 feet 8-2 with ground UF 20-amp 120 VOLT < 100 feet 8-2 with ground UF 30-amp 120 VOLT 100 to 200 feet 6-2 with ground UF 30-amp 120 VOLT 200 to 300 feet #4 copper 30-amp 240 VOLT < 100 feet 12-2 with ground UF 20-amp 240 VOLT 100 to 200 feet 10-2 with ground UF 20-amp 240 VOLT 200 to 300 feet 8-2 with ground UF 20-amp

NAIL PLATES HOLES: Required where edge of hole is less than 1-1/4 inch from face of stud. NOTCHES: Nail plates required over all notches for wiring. P. V. C. Required where PVC piping is less than 1-1/4 inch from face of stud. STAPLES ATTICS SCUTTLE HOLE: Wiring stapled to sides of rafters/ joists within 6-ft of the attic entrance. SPACING: Attic wiring must be stapled not more than 4-1/2 feet apart. BOXES: Wiring must be stapled within 12-inches of each box. WALLS PLASTIC BOXES: Wiring must be stapled within 8-inches of plastic wall boxes. METAL BOXES: Wiring must be stapled within 12-inches of metal wall boxes. STUDS: Wiring must be stapled 1-1/4 inch from the face of the stud. SPACING: Wiring must be stapled not more than 4-1/2 feet apart along studs. WALLS: ATTIC: OUTSIDE: EXPOSED WIRING Exposed wires in wall must be protected with PVC or EMT up to 8-ft above floor Protection required within 6-feet of scuttle hole (unless run on side of joist). Exterior wiring must be protected up to 8-feet above grade. UNDERGROUND WIRING UNDER SLAB: Must be in conduit (PVC) until outside of building. BELOW GRADE: Must be protected by conduit to a depth of 18-inches minimum. ABOVE GRADE: Must be protected by conduit up to 8-feet above grade. BURIAL DEPTH SERVICE CABLE: 24-inches deep to top of cable U. F. ROMEX 24-inches deep to top of romex P. V. C. 18-inches deep to top of conduit RIGID CONDUIT: 6-inches deep to top of conduit DRIVEWAYS: All wiring under driveways must be 24-inches deep minimum. CORROSION: SPLICES: WHERE REQUIRED: POWER: WIRING: ALUMINUM WIRING All aluminum wires must have oxidation inhibitor at terminations. Copper & aluminum can only be spliced with split bolt connectors rated for that use. SMOKE DETECTORS 1. In each sleeping room. 2. Outside each sleeping area (in immediate vicinity). 3. Each story of the dwelling unit. Smoke detectors must be hardwired and have battery backup Smoke detectors must be interconnected to activate all detectors at once

COLOR: REBAR: P. V. C. All electrical PVC must be gray in color and UL listed for electrical use. FOOTER GROUND #4 ground wire must be connected to 20-foot length of rebar in footer and extended to the outside for connection to the ground rod. LIGHTING CLOTHES CLOSETS OPEN BULB: Open bulb incandescent fixtures are not allowed in clothes closets. INCANDESCENT: Enclosed incandescent fixtures must be at least 12 from storage areas. RECESSED: Recessed fixtures must be at least 6 from storage areas. FLUORESCENT: Fluorescent fixtures must be at least 6 from storage areas (shelves). ATTICS: LIGHTS: A switched light must be installed in all attics used for storage. HVAC: A receptacle and light is required in all attics containing HVAC equipment. REQUIRED LIGHTING BATROOMS: KITCHENS: STAIRWAYS: Light fixture required switched at top and bottom of stairs. HALLWAYS: GARAGES: DOORWAYS: Light fixture required at each exterior doorway. OTHER: Bedroom, living rooms, etc. may have switched receptacle instead of light. RANGE: DRYER: SUB PANEL: LENGTH: GALVANIZED: COPPER: PIPE: CLAMP: DEPTH: 4-WIRE CIRCUITS Ranges require a 4-wire circuit, 4-wire receptacle, and 4-wire cord. Ranges require a 4-wire circuit, 4-wire receptacle, and 4-wire cord Sub panels require a 4-wire supply with a separate ground buss at sub panel. GROUND ROD 8-feet long minimum. Galvanized ground rods must be 5/8 minimum diameter. Copper ground rods must be 1/2 minimum diameter. Galvanized pipe ground rods must be 3/4 minimum diameter. Ground clamps at, or below grade, must rated for below ground use. Ground rods must be driven full depth into earth.

120 VOLT COPPER VOLTAGE DROP TABLE Maximum Wire Length (Feet) Current Wire Size Draw 14 12 10 8 6 4 5-amp 115 182 290 461 732 1165 10-amp 57 91 145 230 366 582 12-amp 48 76 121 192 305 485 15-amp 38 61 97 154 244 388 17-amp - 54 85 136 215 343 20-amp - 46 72 115 183 291 25-amp - - 58 92 146 233 30-amp - - 48 77 122 194 40-amp - - - 58 92 146 50-amp - - - 46 73 116 240 VOLT COPPER VOLTAGE DROP TABLE Maximum Wire Length (Feet) Current Wire Size Draw 14 12 10 8 6 4 5-amp 229 364 579 921 1465 2330 10-amp 115 182 290 461 732 1165 12-amp 96 152 241 384 610 971 15-amp 76 121 193 307 488 777 17-amp - 107 170 271 431 685 20-amp - 91 145 230 366 582 25-amp - - 116 184 293 466 30-amp - - 97 154 244 388 40-amp - - - 115 183 291 50-amp - - - 92 146 233