Similar documents
COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

Contents and Nomenclature

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

MAC-120HE-01 Air-Cooled Chiller

Mechanical Rooftop Custom Capabilities

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Local Dealer:

Element D Services Heating, Ventilating, and Air Conditioning

DESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System

How To Understand Evaporator

CODE NOTES. Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

MUELLER FALLING FILM CHILLERS

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

Quality is Our Strength You can count on Oasis Coils

Glossary of Heating, Ventilation and Air Conditioning Terms

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_ Products that provide lasting solutions.

Select Radiators Installation Guide

Dehumidification Frequently Asked Questions

What is LEED? Why pursue LEED accreditation? How does LEED accomplish these goals? Sustainable sites Water efficiency Energy and Atmosphere

DESIGN STANDARDS SECTION

Are these noise cancelling devices needed to make your chiller quiet??

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Chilled Water HVAC Systems

Air Conditioning Clinic

Cooling kw Heating kw

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Nirvana. Cycling Refrigerated Dryers

Commercial Semi-Instantaneous Water Heaters

Product Data. Features/Benefits. AquaForce 30XA Air-Cooled Liquid Chillers. 80 to 500 Nominal Tons (265 to 1740 Nominal kw)

Defining Quality. Building Comfort. Precision. Air Conditioning

HVAC Systems: Overview

How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

ECOCIAT. Domestic hot water heat recovery unit

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

High School Graduation years 2013, 2014, Unit/Standard Number

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

The Different Types of Air Conditioning Equipment for IT Environments

marine/bespoke split applications

HIGH EFFICIENCY RTU. HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

Calculating System Flow Requirements

INSTALLATION & OPERATION MANUAL MODULAR AIR COOLED CHILLER

Ductless Heat Pumps. Gary Nordeen January

Nordic Heat Pump Product Guide

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

1.2 Refrigerant Equipment. General

C26 Bulletin # November 1997 Supersedes January 1997 (Coil/Furnace Match Up Charts)

Characteristics of Evaporators

Steam Coil Installation, Operation and Maintenance

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR

A Comprehensive Laboratory Test to Analyze the Compatability of Leading Cleaners and Sanitizers on Today's Industrial Refrigeration Evaporator Coils.

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

Cased/Uncased Coils For Gas And Oil Furnaces

Test Code: 8297 / Version 1

Solar Hot Water Heaters

Low Profile Unit Cooler

Why Daikin? 2015 Houston, Texas USA

Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain Ship. Wt. Lbs.

CONTENTS. 1 cooling technology white paper

Rusty Walker, Corporate Trainer Hill PHOENIX

Controlled Environment Products & Commercial Refrigeration Price List

Versati Air to Water Heat Pump

Chilled Water Fan Coil Unit. Model:HFCA Size 03~14

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Cast-Iron Performance Meeting today s commercial demands with effi ciency, strength and intelligent controls.

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

6 MECHANICAL HVAC SYSTEMS

Refrigeration Basics 101. By: Eric Nelson

APPLICATION GUIDE. Comparison of Latent Cooling Performance of Various HVAC systems in a Classroom Application

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SMALL DUCT HIGH VELOCITY COMFORT SYSTEM

TWE+TTA TWE+TWA T.R.

A. Section includes air conditioning units, controls and control panels.

LSA LSE, LSR & LST LPA LPE, LPG & LPH LAA LAE, LAG & LAH COMMERCIAL WALK-IN COOLERS AND FREEZERS

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet

ice 3 FLUID TO FLUID HEAT PUMP

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

APC APPLICATION NOTE #112

VACUUM REFRIGERATION SYSTEMS

How To Buy A Lennox Power System

CRAC Precision climate control units for data centres

ASME Packaged Indirect Fired Water Heater

marine refrigeration and air conditioning

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS

Electric & Gas Water Heaters

How To Use A Water Source Heat Pump

SECTION AIR COOLED WATER CHILLERS

AIR-COOLED CONDENSERS Technical Guide

Automobile Air Conditioning Primer

AMERICAN SOLAR WATER HEATING SYSTEM The Best Water Heating Solution Under The Sun

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

Transcription:

Defining Quality. Building Comfort. Heating and Cooling Coils

Heating and Cooling Coils Heating and Cooling Coils For over 20 years, AAON has supplied the coil needs of industrial and commercial HVAC customers. Today, AAON offers a wide selection of chilled water, hot water, steam, and refrigerant fin and tube coil configurations. AAON coils can be easily configured with the AAON ECat selection software from an expansive list of features to meet your coil construction and performance specifications. All AAON coils follow a rigorous manufacturing process and testing routine to ensure they are free from leaks before shipment. Quick Ship Coils Available The AAON design expertise and manufacturing processes allow for emergency quick shipments with lead times as short as one business day. Contact your local AAON representative for further details on available quick shipments. Booster Coils Booster coil configurations are available that are sure to meet your exact needs for supplemental heating. The coil options include tube diameter, rows deep, finned height and length, fin thickness, fin material, fins per inch, tube wall, connection size and type, and casing configuration. Using the AAON ECat selection software, the critical criteria can be selected to ensure that the right AAON booster coil is selected to provide optimum performance in any application. Heating Coils Whether a job calls for steam distributing heat or hot water heat, AAON heating coils are designed to fit any application. All AAON heating coils are available with multiple tubing diameter options, a variety of tube wall thicknesses, and multiple rows deep. Hot water heating coils can be circuited in a full, half, or quarter serpentine circuiting to optimize heating performance. Steam coils are configured as tube-in-tube distributing to maximize performance at low entering air temperature conditions. Since AAON hot water coils are rated for entering water temperatures as high as 200 F and steam distributing coils rated for entering superheated steam as high as 15 psig, AAON heating coils can satisfy the rigorous demands of the HVAC marketplace.

Chilled Water Cooling Coils AAON offers an array of options to satisfy hydronic cooling coil requirements whether the application calls for chilled water only or a glycol solution for freeze protection. With multiple tubing diameter options, coil circuitry options and fin densities, and up to 12 rows deep for additional latent capacity for dehumidification applications, AAON cooling coils can maximize performance regardless of the job specification. Designed to save installation and maintenance time and money, all hydronic coils include factory installed manifolds designed to handle a wide range of water flow rates. World class leak testing equipment and manufacturing processes, and AHRI 410 certification, ensure AAON hydronic coils are the best. AAON chilled water and hot water coils are certified in accordance with AHRI Standard 410, Forced Circulation Air-Cooling and Air-Heating Coils. The AHRI Certification program is administered and governed by AHRI, which ensures that various types of heating, ventilation, air conditioning, refrigeration, and water heating products perform according to manufacturers published claims. Products that are certified through the AHRI Certification Program are continuously tested by an independent third-party laboratory, contracted by AHRI, to determine the product s ability to conform to one or more product rating standards or specifications. Specifying AHRI Certified AAON Coils instills confidence in coil performance. DX Evaporator or Condenser Coils For any system requiring direct expansion refrigerant coils, AAON can provide the evaporator or condenser coil to match the exact need. DX evaporator coils are available with multiple rows, multiple fins per inch options, and can be configured with interlaced or face split circuitry for capacity modulation and capitalize on valuable energy savings. DX condenser coils are available with multiple rows, up to 22 fins per inch, and can be configured with interlaced or face split circuitry. All DX evaporator coils and heat pump condenser coils include rifled tube enhancements and refrigerant distributors that ensure proper refrigerant distribution into the coil. AAON DX coils are designed to maximize performance no matter the specific job requirements. Drawn fin collars increase heat transfer and offer precise fin densities All fins have sine wave enhancements for greater heat transfer efficiency Fins available in either aluminum or copper with a number of different thicknesses to fit the specific application

Coil Leak Testing All AAON coils, whether they are for hydronic or DX systems, surpass all standard industry leak test specifications. Each coil has an individual barcode that is scanned as it follows a rigorous leak test routine including gross leak testing, vacuum decay testing, and final leak testing with trace gas where each outcome being stored electronically for data analysis. Every coil must pass each step of the leak test procedure before it receives final approval and ships to the customer or is installed in one of the world class AAON rooftop units, chillers, outdoor mechanical rooms, air handling units, self contained units, or condensing units. Using the test data, AAON is also able to continually improve the manufacturing processes to offer the best coils available. Condenser coil being scanned prior to leak testing. The results of this test, pass or fail, are stored electronically for further analysis to ensure quality control. Test interface for the leak test chamber. Operators are able to see real time results. Leak test chamber where coils go through gross leak and trace gas leak testing.

AAON Selection Software The AAON ECat software allows each coil selection to precisely match your application requirements. The coil can be configured based on the desired MBH, with the ECat software varying the rows, fins per inch, and circuitry to find the closest match. The coil can also be configured based on specific coil characteristics input with the ECat software providing a performance rating. The software calculates coil performance including sensible and latent capacity, airside pressure drop, leaving air conditions, and even glycol solution ratings. Coil options in the ECat software are nearly limitless with the flexibility to select specific fin densities, specific tube diameters and circuitry to optimize pressure drop through the coil. The AAON ECat selection software gives you the assurance that the designed coil will meet the exact needs of your job specifications. Coil Specific Performance Rating Sheet and Coil Specific Drawing Booster Coil Details Fin densities from 8 to 16 fins per inch to optimize performance and air side pressure drop Slip and Drive Coil Casing Coil inlet and outlet available with either sweat or threaded connections (MPT or FPT) Booster Coils Tube Material Fin Material Casing Material Casing Rows FPI Circuitry Tube Diameter (OD) Connection Optional Corrosion Protection Hot Water or Steam Aluminum or G90 Galvanized, Aluminum, or 304 Stainless Steel U-Flange, Slip and Drive or None Up to 12 Up to 16 Quarter to Double Serpentine, or Steam Distributing 1/2 or 5/8 Sweat, MPT, or FPT* Polymer E-Coating * MPT (Male Pipe Thread) and FPT (Female Pipe Thread)

Hydronic Coil Details Fin densities from 8 to 16 fins per inch to optimize performance and air side pressure drop Up to 12 rows circuited to optimize coil performance and water side pressure drop Standard coils are completely encased for structural integrity but can be manufactured without casing for a specific application. Manifolds designed to minimize water side pressure drop for a range of flow rates. Coil inlet and outlet available with either sweat (as shown) or threaded connections (MPT or FPT) Manifolds include drain plug, vent plug, and Schrader valves to allow verification of positive pressure and leak free coils Hydronic Coils Tube Material Fin Material Casing Material Casing Rows FPI Circuitry Tube Diameter (OD) Hot Water Quarter to Double 1/2 or 5/8 Coils G90 Galvanized, U-Flange, Slip Serpentine Aluminum or Steam Coils Aluminum, or 304 and Drive or Up to 12 Up to 16 Steam Distributing 5/8 Stainless Steel None 1/2 or 5/8 Chilled Water Coils Quarter to Double Serpentine * MPT (Male Pipe Thread) and FPT (Female Pipe Thread) Connection Sweat, MPT, or FPT* Optional Corrosion Protection Polymer E-Coating

DX Coil Details Fin densities from 8 to 20 fins per inch to optimize performance and air side pressure drop 6 row high capacity available for dehumidification applications and increased energy efficiency. Gas flux brazing on all distributors for a cleaner joint with less refrigerant leaks Every coil has a unique barcode that allows thorough analysis of every step of the manufacturing process Factory installed TXV equalizer line to ensure expansion valve functionality Coils are completely encased for structural integrity Interlaced or face split circuiting for capacity modulation Stepped suction manifold to prevent compressor liquid refrigerant returning to the compressor and therefore extend compressor life DX Coils Tube Material Fin Material Casing Material Casing Rows FPI Circuitry Tube Diameter (OD) Connection Optional Corrosion Protection Evaporator Coils Condenser Coils Aluminum or G90 Galvanized, Aluminum, or 304 Stainless Steel U-Flange, Slip and Drive or None Up to 12 Up to 20 Up to 24 Face Split or Interlaced 3/8 or 1/2 3/8 or 7mm Sweat, MPT, or FPT* Polymer E-Coating * MPT (Male Pipe Thread) and FPT (Female Pipe Thread)

Corrosion Protection All AAON coils can be selected in ECat with the industry leading corrosion protection of a 6,000-hour salt spray tested polymer e-coating of the entire coil, not just the fin pack. With less than a 1% reduction in heat transfer, the polymer e-coating allows coated coils to perform as designed. After two continuous years of simulated harsh coastal service, polymer e-coated coils saw no degradation in performance as compared to nearly a 60% reduction coil performance of a non-coated coil. Also available are AAON coils with copper tubes, copper fins and aluminum or 304 stainless steel coil casing. fin and tube construction helps to avoid galvanic corrosion in the fin pack, and aluminum or stainless steel casing helps to prevent corrosion of coil casing. Polymer E-coated Coils Coating Quality Test Procedure Coating Performance Dry Film Thickness ASTM D7091-05 0.8-1.2 mils Water Immersion ASTM D870-02 1,000+ hours Salt Spray ASTM B117-97 6,048+ hours Heat Transfer Reduction AHRI 410 <1 % Operaitng ph Range n/a 3-12 Tube and Fin Coil? Don t see the specific coil you need? AAON can meet your requirements with custom coils designed specifically for your exact application. Polymer E-Coated Coils For more information about AAON coils, contact your local AAON sales representative. Defining Quality. Building Comfort. 2425 S. Yukon Ave. Tulsa, OK 74107-2728 www.aaon.com It is the intent of AAON to provide accurate and current product information. However, in the interest of product improvement, AAON reserves the right to change pricing, specifications, and/or design of its product without notice, obligation or liability. Copyright AAON, all rights reserved throughout the world. AAON and AAONAIRE are registered trademarks of AAON, Inc., Tulsa, OK. Coils V13310 140219