CASED & UNCASED UPFLOW & DOWNFLOW EVAPORATOR COILS

Similar documents
Cased/Uncased Coils For Gas And Oil Furnaces

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

DESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO

ARMSTRONG AIR HEAT PUMPS

Evaporator Coil Installation Instructions

Cooling/Heat Pump Convertible Air Handlers

Cooling Capacity CFM in. w.c. (125 Pa)

How To Install An Evaporator Coil

OIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.

C26 Bulletin # November 1997 Supersedes January 1997 (Coil/Furnace Match Up Charts)

Installation Instructions

Greensource iseries HY Model Unitary Air Handler/Fan Coil

Local Dealer:

Evaporator Coils. Upflow/Downflow Vertical N-Coil Transition Upflow/Downflow N-Coil Horizontal N-coil. Upflow/Downflow Uncased Vertical N-Coil

Commercial Gas Furnace Upflow

AIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency

TECHNICAL MANUAL GDS8 & GHS8

SECTION MORTUARY REFRIGERATORS

ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features

Evaporator Coil. Installation Instructions GENERAL

HA HE Series. Solutions for Your needs. fl exible and confi gure-to-order coils. Healthy Solutions coils

Installer s Guide 18-AH39D1-13

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

G9MXE. Product Specifications

2/4CXC, 2/4CXA, 2/4TXC 2/4TXFH

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

F9MXE. Product Specifications

Using the Aspen Catalog is very simple. Go to Bookmarks on the left side of your screen

CEILING CASSETTE FAN COIL UNIT

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Split System Heat Pump Product Data

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

PRODUCT CATALOG. Aspen Manufacturing - Evaporator coils - Air Handlers - Manufactured Home Products - Light Commercial Coils

CB29M Bulletin # February 1996

Split System Cooling Product & Performance Data

Split System Heat Pump Product Data

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler

Split System Cooling Product Data

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

RHEEM RESIDENTIAL AIR CONDITIONING

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

CE6500 Energy Recovery Ventilator

Split System Cooling Product Data

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV Comfortnet Compatible 1½ to 5 Tons. Contents.

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Split System Cooling Product Data

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

GCS16 GCS20 WARNING CAUTION

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

Below are detailed instructions for using the EMS load calculator.

WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1

XV 95. Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace PUB. NO.

DUCT SYSTEM DESIGN CONSIDERATIONS Part 1

How To Install A Perfect 16 Id Series Filter System

Split System Cooling Product Data

INSTALLATION INSTRUCTIONS

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

OIL FURNACES. Clean, Comfortable Oil Heat From

RHF High Efficiency Remote Heat Pumps and Matching Blower Coils

SECTION HEAT PUMPS

Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain Ship. Wt. Lbs.

Single Package Vertical Air Conditioners. Vert-I-Pak

Split System Heat Pump Product Data

Ceiling Mount Air Handler Manual

Geothermal Comfort Systems

TWE+TTA TWE+TWA T.R.

MAC-120HE-01 Air-Cooled Chiller

SPLIT-SYSTEM CONDENSING UNITS SEER HRA018 thru 060 (1.5 thru 5 Nominal Tons) DESCRIPTION FEATURES

E2 Series Electric Furnaces

Split System Heat Pump Product Data

Installation Instructions

Glossary of Heating, Ventilation and Air Conditioning Terms

The Embassy of the United States of America invites you to submit an offer for supply and install the following A/Cs:

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

LPM-06 CONVERSION KIT

GCS

TAMPERS Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.

ASME Packaged Indirect Fired Water Heater

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

Product Data. Split System Cooling F-EN. March 2015

HV AC CODE CHECKLISTS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Think Green Think Renewable Think

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

APPENDIX 7.2. DECODING OF MANUFACTURER MODEL NUMBERS LIST OF TABLES

Element D Services Heating, Ventilating, and Air Conditioning

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

Model 1210C Battery Powered Pump Shown. Description

Why Daikin? 2015 Houston, Texas USA

Evaporator Coils INSTALLATION INSTRUCTIONS WARNING WARNING WARNING WARNING * * Save these instructions for future reference

Type D3 PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description

AVPTC**14** AIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS

Dehumidification Frequently Asked Questions

Transcription:

CASED & UNCASED UPFLOW & DOWNFLOW EVAPORATOR COILS Description / Application Compact, versatile, right or left horizontal position May be used in closet, utility room, or basement Standard Finish Fully insulated cabinet on cased coils Equipped with a check flowrator for heat pump and cooling unit operation No rust high temperature thermoplastic drain pans for upflow and downflow application with secondary drain Construction Insulated steel cabinet Cabinet Finish No rust galvanized stucco finish SS-208D Rev. M Accessories Downflow kit (DFK) used for all multi-position furnaces for downflow applications Made in the USA by: Goodman Manufacturing Company, L.P. 2550 North Loop West, Suite 400 Houston, TX 77092 www.goodmanmfg.com 1 U/UC SERIES 02/03

UNCASED UPFLOW EVAPORATOR COILS UC-18 THRU UC-42, UC-47, UC-49, UC-59, & UC-62 A SHAPED SLAB SUCTION 3/4 FEMALE NPT PRIMARY & SECONDARY DRAIN S (IMPORTANT: HAND TIGHTEN) UC-60 & UC-61 SUCTION 3/4 FEMALE NPT PRIMARY & SECONDARY DRAIN S (IMPORTANT: HAND TIGHTEN) DIMENSIONS (INCHES) SPECIFICATIONS STATIC NO. SUCTION SHIP A B C PRESSURE MODEL TONS CFM ROWS CONN. CONN. WT. WET COIL UC-18 1 1/2 13 14 1/4 20 1/8 650 0.20 2 3/8 5/8 14 UC-29 *2-21/2 13 14 20 1/8 900 0.20 2 3/8 3/4 16 UC-32 2 1/2 13 17 7/8 20 1/8 1000 0.30 3 3/8 3/4 24 UC-35 3 13 18 1/4 20 1/8 1200 0.30 2 3/8 3/4 18 UC-36 3 17 17 1/2 20 1/8 1200 0.25 2 3/8 3/4 19 UC-42 3 1/2 17 17 3/4 20 1/8 1400 0.30 3 3/8 3/4 34 UC-47 4 17 22 1/8 20 1/8 1600 0.30 3 3/8 7/8 31 UC-49 4 19 3/4 21 7/8 20 1/8 1600 0.30 3 3/8 7/8 33 UC-59 5 19 3/4 25 7/8 20 1/8 2000 0.30 3 3/8 7/8 36 UC-60 5 20 1/4 21 1/4 23 2000 0.30 3 3/8 7/8 42 UC-61 5 20 1/4 22 23 2000 0.30 4 3/8 7/8 44 UC-62 5 19 3/4 26 1/8 20 1/8 2000 0.30 4 3/8 7/8 47 NOTES: 1) SEE BACK SHEET FOR INSTALLATION TIPS. 2) DO NOT USE THIS COIL ON OIL FURNACES OR ANY APPLICATIONS WHERE THE TEMPERATURE ON DRAIN PAN MAY EXCEED 300 F. USE THE FOLLOWING METAL DRAIN PANS: 15236-18 (U-18 THRU U-32), 15236-19 (U-36 THRU U-47), 15236-20 (U/UC-60 THRU U-61), AND FIELD FABRICATED METAL PAN FOR (U/UC-49, U/UC-59, AND U/UC-62). 3) * UC-29 COMES WITH 2 TON FLOWRATER B13134-59. IF 2-1/2 TON MATCHING IS REQUIRED, INSTALL PROVIDED PISTON KIT B17898-65. 2

CASED UPFLOW EVAPORATOR COILS U-18 THRU U-42, U-47, U-49, U-59, & U-62 SUCTION LINE CONN. 3/4 FEMALE NPT PRIMARY & SECONDARY DRAIN S (IMPORTANT: HAND TIGHTEN) U-60 & U-61 20 1/4 23 3/8 D F SUCTION LINE LINE 3/4 FEMALE NPT PRIMARY & SECONDARY DRAIN S IMPORTANT:HAND TIGHTEN 20 3/8 21 1/8 DIMENSIONS (INCHES) SPECIFICATIONS STATIC NO. SUCTION SHIP A B C D E F PRESSURE MODEL TONS CFM ROWS CONN. CONN. WT. WET COIL U-18 1 1/2 14 1/4 12 3/4 14 1/2 13 1/4-650 0.20 2 3/8 5/8 24 U-29 *2-21/2 14 1/4 12 3/4 14 1/2 13 1/4-900 0.20 2 3/8 3/4 26 U-30 2 1/2 18 1/4 17 1/4 16 1/2 17 1/4-1000 0.30 2 3/8 3/4 33 U-31 2 1/2 14 1/4 12 3/4 14 1/2 13 1/4-1000 0.30 3 3/8 3/4 30 U-32 2 1/2 18 1/4 17 1/4 16 1/2 17 1/4 2 1000 0.25 3 3/8 3/4 41 U-35 3 14 1/4 12 1/4 14 1/2 13 1/4 4 1/8 1200 0.30 2 3/8 3/4 29 U-36 3 18 1/4 17 1/4 16 1/2 17 1/4 1 3/4 1200 0.30 2 3/8 3/4 40 U-42 3 1/2 18 1/4 17 1/4 16 1/2 17 1/4 2 1400 0.30 3 3/8 3/4 48 U-47 4 18 1/4 17 1/4 16 1/2 17 1/4 6 1600 0.30 3 3/8 7/8 50 U-49 4 21 1/8 20 1/8 27 1/2 20-1600 0.30 3 3/8 7/8 51 U-59 5 21 1/8 20 1/8 27 1/2 20-2000 0.30 3 3/8 7/8 54 U-60 5 24 1/4 23 1/8 20 1/2 1/2 20 1/8 1 2000 0.30 3 3/8 7/8 60 U-61 5 24 1/4 23 1/8 20 1/2 1/2 20 1/8 1 5/8 2000 0.30 4 3/8 7/8 62 U-62 5 21 1/8 20 1/8 27 1/2 20-2000 0.30 4 3/8 7/8 68 NOTE: FOR DRAIN PAN SPECIFICATIONS, REFER TO NOTE 2 ON PAGE 2. 1) * U-29 COMES WITH 2 TON FLOWRATOR B13134-59. IF 2 1/2 MATCHING IS REQUIRED, INSTALL PROVIDED PISTON KIT B17898-65. 3

STATIC PRESSURE DROP ACROSS COIL Air Flow Data - Static Pressure Drop Across Coil - Upflow Application COIL MODEL AIR QUANTITY (CFM) CFM 400 500 600 700 800 900.00 1000 1100 U18/UC18 WET 0.10 0.12 0.18 0.25 DRY 0.08 0.10 0.12 0.19 U29/UC29 CFM 600 700 800 900 1000 1100 1200 1300 /30 WET 0.12 0.16 0.20 0.25 0.30 DRY 0.08 0.10 0.13 0.16 0.21 U32/UC32 CFM 700 800 900 1000 1100 1200 1300 1400 U31 WET 0.16 0.22 0.24 0.28 0.34 DRY 0.10 0.16 0.18 0.24 0.27 U36/UC36 CFM 800 900 1000 1100 1200 1300 1400 1500 U35/UC35 WET 0.13 0.16 0.20 0.24 0.28 0.30 DRY 0.10 0.12 0.14 0.18 0.24 0.28 U42/UC42 CFM 900 1000 1100 1200 1300 1400 1500 1600 U47/UC47 WET 0.12 0.16 0.20 0.24 0.27 0.30 0.34 DRY 0.10 0.13 0.15 0.18 0.20 0.22 0.26 CFM 1200 1300 1400 1500 1600 1700 1800 1900 U49/UC49 WET 0.14 0.18 0.22 0.26 0.30 0.34 DRY 0.12 0.14 0.17 0.19 0.22 0.26 U59/UC59 CFM 1600 1700 1800 1900 2000 2100 2200 2300 U60/UC60 WET 0.17 0.21 0.24 0.27 0.30 0.33 0.36 0.40 DRY 0.13 0.14 0.19 0.22 0.25 0.29 0.32 0.36 U61/UC61 CFM 1600 1700 1800 1900 2000 2100 2200 2300 U62/UC62 WET 0.19 0.22 0.26 0.29 0.32 0.36 0.40 0.45 DRY 0.15 0.17 0.21 0.25 0.28 0.32 0.35 0.39 UC COIL INSTALLATION RECOMMENDATIONS MINIMUM DISTANCE BETWEEN FURNACE AND COIL PAN = 2 DOWNFLOW APPLICATIONS NOTE: A. Do not use this coil on oil furnaces or any applications where the temperature on drain pan may exceed 300 F. Use the following metal drain pans: 15236-18 (U-18 thru U-32), 15236-19 (U-36 thru U-47), and 15236-20 (U/UC-60 thru U-61). B. Due to the rating mix/match of various coils with outdoor units it is important to match the furnace air flow for the total system capacity. (Refer to furnace spec. sheet & condenser/heat pump spec. sheet.) 4

CASED (U) COIL APPLICATION OPTIONS GMP050-3 GDT045-3 GMP075-3 GDT090-4 GMP100-5 GDT115-5 GMP150-5 GMP050-32(C) GDT070-3 GMP100-3 GMNT080-4 GMP125-4 GMNT100-4 GMP150-52(C) GMP075-3 GMNT040-3 GMP100-4 GPD100-4 GMP125-5 GPD125-4 GMPH120-5 GMP075-32(C) GMNT060-3 GMP100-42(C) GMP125-52(C) GMPN120-5 GMPH050-3 GPD050-3 GMPE075-3 GMPE100-4 GMT140-5 (ND) GMPN040-3 GPD075-3 GMPH075-4 GMPE125-5 FURNACE GMPN060-3 GMPN080-4 GMPH080-5 MODEL GMNT120-5 NO. GMT045-3 (ND) GMT070-4 (ND) GMPN100-4 GMT070-3 (ND) GMT090-3 (ND) GMT090-5 (ND) GMTH045-3 (ND) GMT090-4 (ND) GMT115-5 (ND) GSM060-3 (ND) GMTH070-4 (ND) GMTH115-5 (ND) GSMS060-3 (ND) GSM080-4 (ND) GSM100-4 (ND) GSU060-3 (*) GSMS080-4 (ND) GSMS100-4 (ND) GSU080-4 (*) GSU100-4 (*) FURNACE WIDTH 14 14 17 1/2 17 1/2 21 21 24 1/2 24 1/2 DFK DFKT-17 DFK - 14 DFKT-14 DFK - 17 MODEL NO. (3) DFK - 21 DFKT - 21 DFK 24 DFKT 24 MODEL COIL NO. WIDTH U-18 14 X X U-29 14 X X U-30 17 1/2 X(1) X(1) X(2) X(2) U-31 14 X X U-32 17 1/2 X(1) X(1) X(2) X(2) U-35 14 X X U-36 17 1/2 X(1) X(1) X(2) X(2) U-42 17 1/2 X(1) X(1) X(2) X(2) U-47 17 1/2 X X U-49 21 X(1) X(1) X(2) X(2) U-59 21 X(1) X(1) X(2) X(2) U-60 24 1/2 X(1) X(1) X(2) X(2) U-61 24 1/2 X(1) X(1) X(2) X(2) U-62 21 X(1) X(1) X(2) X(2) (1) Utilizing factory installed bottom cabinet filler plates. (2) Discard bottom cabinet filler plates (3) Downflow Coil Adapter Kit allows use of U coils in downflow applications. (*) Upflow Application only (ND) Not for Downflow NOTE: SPECIFICATIONS AND PERFORMANCE DATA LISTED HEREIN ARE SUBJECT TO CHANGE WITHOUT NOTICE Quality Makes the Difference! All of our systems are designed and manufactured with the same high quality standards regardless of size of efficiency. Our designs virtually eliminate the most frequent causes of product failure. They are simple to service and forgiving to operate. We use the highest quality materials and components available because if a part fails then the unit fails. Finally, every unit is run tested before it leaves the factory. That s why we know... There s No Better Quality. Visit our website at www.goodmanmfg.com for information on: Goodman Products Warranties Customer Services Parts Contractor Programs and Training Financing Options 5