MicroScanner 2. Cable Verifier. Getting Started Guide



Similar documents
MICROMAPPER. Users Manual. LAN Wiremap Checker

MicroScanner 2. Users Manual. Cable Verifier

How To Use The Visifault Visual Fault Locator

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.


CableIQTM. Users Manual. Qualification Tester

CableIQTM. Users Manual. Qualification Tester

K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)

INSTRUCTION MANUAL. NC-500 NETcat Pro Wiring Tester

i410/i1010 AC/DC Current Clamp

Temperature Humidity Meter

Dolphin 9900 Mobile Computers

QUICK INSTALLATION. 8-Port Telephony Gateway. Model: SPA8000

AXIS T81B22 DC 30W Midspan

CO-220 Carbon Monoxide Meter

Multi Media Cable Tester TM-901N/TM-902/TM-903

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

User manual. Your best protection against theft and loss. (Android) Made for

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

DTX Series. Users Manual. CableAnalyzer

LinkRunner Pro TM. Network MultiMeter Quick Reference Guide. Welcome. What s in the box?

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

HVAC Clamp Meter. Users Manual

PagePac PAGEPAL V

KVM - DVI, USB 2.0, Cat 5 Extender

16-Port and 24-Port 10/100 Switches

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

Automatic Phone-Out Home Monitoring Systems

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

80PK-27 SureGrip TM Industrial Surface Temperature Probe

User s Manual. Bluetooth Calculator Keypad. Page

Installation Guide for. 10/100 to Triple-speed Port Aggregator. Model TPA-CU Doc. PUBTPACUU Rev. 1, 12/08. In-Line

Regulatory Compliance. IC Certification. FCC Certification. Declaration of Conformity

Alarm Clock USER GUIDE

Installation Guide for Gig Zero Delay Tap and 10/100/1000BaseT Tap

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Installation Guide for. 10/100BaseT Port Aggregator Tap with Active Response. Models PA-CU-AR, PAD-CU-AR. Doc. PUBPACUARU Rev.

DTX Series. Technical Reference Handbook. CableAnalyzer TM

USB/VGA Cat 5 UTP Console Extender

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

USB to IDE or SATA Adapter

Dolphin 6500 Mobile Computer. with Windows CE 5.0. Quick Start Guide

Crow Limited Warranty. Print Version 017

ReadyNet Easy Jack 2 Voice/Data and Data Only Owner s Manual PX-211d and PX-211v

Ultrasonic Distance Meter. Operation Manual

HANDS-FREE BLUETOOTH CONTROLLER for SMART READY TABLETS AND COMPUTERS

Dock-N-Talk U S E R S G U I D E. Forming a New World of Communication. SM

CM100. Carbon Monoxide Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso Användarhandbok

User Manual (English)

Start Here Series. All-in-One Printer. Print Copy Scan. Includes Information on the: ESP 3250 All-in-One Printer ESP 3260 All-in-One Printer

TRIPLETT TDR. Cable Fault Finder. Instruction Manual

Quick Start Guide. Model #s: / / / / Lit# /02-10

Installation Guide E Dielectric Probe Kit 85071E Materials Measurement Software

CABLE MODEM QUICK START

SignalTEK II. Save money by using a single multifunction device in place of separate copper, fiber and Power over Ethernet (PoE) testers

Copyright. Trademarks

Powerware Relay-Serial Card User s Guide

Terminal and Dimension

Copyright. Trademarks

15 Digital Photo Frame Instructional Manual

User Manual. Humidity-Temperature Chart Recorder. Model RH520

How To Use An Imclean Dad (Dvd) With A Car Or Car (Dcd) On A Computer Or Car

VDSL Ethernet LAN Extender

323/324/325. Calibration Manual. Clamp Meter

for DNE-K07 Reference and Installation Manual

Conference Phone UserÕs Manual. Part No R1 Printed in Korea Bogen Communications, Inc.

AVerMedia AVerKey imicro User s Manual

AN SMSC Design Guide for Power Over Ethernet Applications. 1 Introduction. 1.1 Power Over Ethernet

Targus Wireless RF Mouse USER S GUIDE. Making Your Mobile Life Easier.

TerraWave Solutions MIMO Site Survey Battery Pack (Part # TW-SSBP-007) Instructions For Use

User Manual PT-E-HIP

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

10/100 Power over Ethernet Kit 48V Injector and 5V/ 12V Splitter

hello. welcome to smart watering.

Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports

USB Rover port USB m Cat 5 Extender. User Guide

USB Port Extender Kit

Terayon DOCSIS Modem Installation. Guide

LCD5500Z / PKP-LCD v3.x Installation Instructions

User's Guide. Integrating Sound Level Datalogger. Model Introduction

NaviTEK II. idealnwd.co.uk. Save money through using a single multifunction device for testing copper and fibre networks

Limited Warranty. CAUTION: Federal law restricts this device to sale, distribution and use by or on the order of a physician.

Caller-ID on your TV!

5006 Centrex AuxBox. Call Recording for Meridian Digital Centrex Telephones. Hardware & Installation Guide

4 Port PCI Express Gigabit Ethernet PoE PSE Network Card

Advantium 2 Plus Alarm

3800 Linear Series. Quick Start Guide

Network Design. Yiannos Mylonas

VIBRATION WATCH with: Vibration Alarm (won't disturb others). Beep Alarm (optional) Electro-Luminescent (EL) back light (for viewing display at

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

Laptop Power Adapter for home/office User Manual

Transcription:

MicroScanner 2 TM Cable Verifier Getting Started Guide PN 2739668 (English) January 2007 2007 Fluke Corporation. All rights reserved. Printed in China. All product names are trademarks of their respective companies.

LIMITED WARRANTY AND LIMITATION OF LIABILITY Fluke Networks guarantees this product to be free from defects in material and workmanship for one year from the date of purchase. Parts, accessories, product repairs and services are warranted for 90 days, unless otherwise stated. Ni-Cad, Ni-MH and Li-Ion batteries, cables or other peripherals are all considered parts or accessories. This warranty does not cover damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke Networks behalf. To obtain service during the warranty period, contact your nearest Fluke Networks authorized service center to obtain return authorization information, then send your defective product to that Service Center with a description of the problem. THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE NETWORKS IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. 4/04 Fluke Networks PO Box 777 Everett, WA 98206-0777 USA

MicroScanner 2 Cable Verifier Accessing the Users Manual This guide provides basic information to help you get started using the tester. For additional information, see the MicroScanner 2 Cable Verifier Users Manual on the Product CD. Safety WWarningX To avoid possible fire, electric shock, personal injury, damage to equipment, or inaccurate test results, read the safety information in the MicroScanner 2 Cable Verifier Users Manual before using the tester. Keys Combinations of keys provide additional functions. See the Users Manual. Selects the active port (RJ45 or coaxial Navigation and toner song selection Selects the test mode Power key 1

MicroScanner 2 Getting Started Guide Display Features O A Tester icon P egs02.eps B Detail screen indicator. To see detail screens, press E or Dduring a cable test; then press E or D. C Indicates which port is active, the RJ45 port (U) or the coaxial port (T) D Tone mode indicator E Power over Ethernet mode indicator F Numeric display with feet/meters indicator G Test activity indicator H Appears when the toner is in IntelliTone mode I Indicates a short on the cable 2

Changing the Length Units J Telephone voltage indicator. P and N appear in the wiremap diagram over the positive (tip) and negative (ring) wires. K Indicates a wiremap adapter is connected to the far end of the cable L Low battery indicator M Indicates an ID locator is connected to the far end of the cable and shows the locator s number N Ethernet port indicator O Wiremap diagram. The rightmost segments indicate the shield. P The Windicates a fault or high voltage on the cable. SPLIT appears when the fault is a split pair. Changing the Length Units 1 Hold down Y and E while turning on the tester. 2 Press M to switch between meters and feet. Auto Shutoff The tester turns off after 10 minutes if no keys are pressed and nothing changes at the tester s connectors. 3

MicroScanner 2 Getting Started Guide Testing Cabling Note A wiremap adapter or remote ID locator must be connected to the end of the cabling for the wiremap to be completely verified. 1 Press X to turn on the tester. 2 Press Y to switch between twisted pair (U) and coaxial (T) modes. 3 Connect as shown in the following figures. Note If the PoE indicator appears, see page 7. Connecting to Twisted Pair Network Cabling Patch panel RJ45 patch cords Wall outlet Wiremap adapter egs03.eps 4

Testing Cabling Connecting to a Bus Topology Distribution center Connection to bus Wiremap adapter RJ11 patch cord Note: Locations of the tester and wiremap adapter may be swapped. egs17.eps Connecting to a Star Topology Distribution center Common connection to bridge tap Wiremap adapter RJ11 patch cords Note: For a correct length reading, connect the tester and wiremap adapter as shown. See the Users Manual for details. egs16.eps 5

MicroScanner 2 Getting Started Guide Connecting to Coaxial Cabling Connection to service Coaxial patch cords Wiremap adapter egs19.eps Using the Toner 1 Press Y to select twisted pair (U) or coaxial (T) cable. 2 Connect the tester to the cable. 3 Press M until L appears on the display. 4 To cycle through the IntelliTone and analog toner songs, press E or D. 5 Use an optional IntelliTone probe or an analog probe to locate the cable. Notes If the PoE indicator appears, see page 7. Auto shutoff is disabled in toner mode. 6

Detecting Power Over Ethernet Detecting Power Over Ethernet The tester can detect PoE voltages from active 802.3af sources. To select PoE mode, press Muntil PoE appears on the display. In PoE mode, the tester solicits PoE power on pairs 1,2-3,6 and 4,5-7,8. The tester may activate a PoE source and will not be damaged by PoE power. If PoE power is detected, Poeappears above the powered pairs. The Poemay blink as the PoE source turns the power on and off. In twisted pair test mode, a flashing PoE mode indicator means that PoE power may be available. To verify the presence of a PoE source, switch the tester to PoE mode. 7

MicroScanner 2 Getting Started Guide Replacing the Batteries The batteries last for about 20 hours of typical use. egs28.eps Contacting Fluke Networks www.flukenetworks.com support@flukenetworks.com +1-425-446-4519 Australia: 61 (2) 8850-3333 or 61 (3) 9329 0244 Beijing: 86 (10) 6512-3435 Brazil: 11 3044 1277 Canada: 1-800-363-5853 Europe: +44-(0)1923 281 300 Hong Kong: 852 2721-3228 Japan: 03-3434-0510 Korea: 82 2 539-6311 Singapore: +65-6799-5566 Taiwan: (886) 2-227-83199 USA: 1-800-283-5853 Visit our website for a complete list of phone numbers. 8