Cabling Collection for Silicon Detectors



Similar documents
Van den Hul Audio and Video Cable/Connector Wiring Diagrams for DIY purposes

maxon motor maxon motor control EPOS Positioning Controller Cable Starting Set Edition June 2006 part number Positioning Controller

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

Directory chapter 04

Gold Eagle HV Gold Eagle HV Cable Kit (EtherCAT and CAN)

Connectors and Cables

Cables KEITHLEY (U.S. only) ACCESSORIES

AudioJoG (TM) Pro 8 Connector PIN LABEL LED Connector PIN LABEL LED. Operations Manual 3.5mm & 6.35mm Mono/Stereo Jacks

Cable Specifications. T3 Trunk Cabling APPENDIX

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

Single Channel Loop Detector

Chapter 1 // Computer Cables THE WORLD OF CABLES. delivery of stock goods in 24 hours. certified quality

ARDUINO SEVERINO SERIAL SINGLE SIDED VERSION 3 S3v3 (REVISION 2) USER MANUAL

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

Contents. Safety Warnings... 1

Cabling Specifications

Connectors, Adapters, and Tools

Tech Info Document: PIC16F84A LCD Satellite Antenna Tracking Interface

G4HUP Panoramic Adaptor Installation FT847

Termination Procedure for No. 12 Series Soldertacts Contacts for Coaxial Cable: D , D

BMD16N-SD. version 1.2

Standard LIGO Electrical Interfaces

Connecting Your Receiver to the Antenna

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

LocoNet, the Digitrax Difference

Cumbria Designs T-1. SSB/CW Filter kit (4.9152MHz) User Manual

TELIKOU Intercom System. TM-200 Main Station. Instruction Manual

Combi B Alarm box. Mounting instructions

Instruction Manual. Cable Splicing. Models , HDF1, HDF SS1

How To Check A Multicore Cable

PERSONAL MONITOR MIXER/HEADPHONE AMP. S Class Signal Processors

K-Type Thermocouple Sensor User s Guide

THE MclNTOSH MC 2100 SOLID STATE STEREO POWER AMPLIFIER

Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness

Silicon Drift Detector Product Brochure Update 2013

Research RF Sputtering Packages

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

revolution Contents: Introduction Power 28-pin Project Board with input/output cables

1993 ACCESSORIES & EQUIPMENT Volkswagen Instrument Panels. Volkswagen; EuroVan, Passat

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

EH-20 20m antenna. By VE3RGW

10/100BASE-T Copper Transceiver Small Form Pluggable (SFP), 3.3V 100 Mbps Fast Ethernet. Features. Application

OVERVIEW NETWORK INTERFACE MODULES

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

LDG DTS-4/4R Desktop Coaxial Switch / Remote

A&C Solutions: please contact us.

F(t) Forssell Technologies Inc

PSC RF Multi SR Six Pack

Assembly Instruction CAI- Connector with universal Endbell

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Build A Video Switcher. Reprinted with permission from Electronics Now Magazine September 1997 issue

Informe Técnico IT - CDT

RC HELICOPTER INSTRUCTION MANUAL

LOXONE 12 Channel Amplifier

The UlTimaTe in PremiUm ConneCTion

Crosstalk effects of shielded twisted pairs

CW46S GPS Sensor P R O D U C T B R I E F. Description. Features. Applications. Block Diagram

Quick Connect Boxes Inside Gloveboxes

CAN - Wiring Notes on the Wiring of CAN-Bus Systems and the Cable Selection

400 Series Buccaneer BUCCANEER POWER. bulgin

Power Supply and Cabling Options. SmartTrak 100/101/140

TG24 / 48 LIGHTING CONTROLLER

Description of the cable under test (CUT)...3

Design Tips for Low Noise Readout PCBs Or: How black magic can lead to success

PSP3. Stereo M/S preamplifier. User manual

What ensures easy and fast wiring?

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

Electronic Circuit Construction:

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

MoTeC USA GPS. Part # M GPS BL Available in 10 Hz or 20 Hz. USER MANUAL Version 1.4

Accelerating Light. Copper Cabling Solutions. Category 6A

R&S ZVA-Z75, -Z110, -Z140, -Z170, -Z220, -Z325, -Z500 Converters Quick Start Guide

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

XRS-4 X-RAY SOURCE OPERATOR S MANUAL

Total solder points: 167 Difficulty level: beginner advanced DMX CONTROLLED RELAY K8072 ILLUSTRATED ASSEMBLY MANUAL

Neo-Neon. LED Vision Mesh Screen Operation Manual. LED Vision Mesh Screen. Neo-Neon International Ltd He Shan Decorative Lighting Company Limited

Multi-Protocol decoder with Load regulation

An Ethernet Cable Discharge Event (CDE) Test and Measurement System

MICRO SFP+ CONNECTOR & CABLE ASSEMBLY

MGL Avionics CAN bus interface for Trig Avionics TT21/TT22 transponders

User s Manual. BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide ( )

Measurement setup for differential-mode and common-mode channels

BUILD YOUR OWN RC SWITCH (Issue 3)

Fibre Optic Solutions for your Test and Instrumentation needs

400 Series - Mini USB Buccaneer

Modifying the Yaesu FT-847 External MHz Reference Input

Product Information. HMC 6 Hybrid Motor Cable

MASTERSOUND. M a s t e r E m o t i o n. PF 100 Limited. Made in Italy

Siemens Energy & Automation. structured. WIRING Product Training Series: Advanced Video Session 3

R O A D M A S T E R, I N C.

A full spectrum of custom cables

Coaxial Cables for Medium-Frequency Applications

Connector and Cable Specifications

We hope that every customer sets up CC-Link system easily by reading this documentation.

You motor now is ready to run. Wires Connection: Installing the Controller: Normal start up:

TS510 & TS500. Installation & User Guide. Compatible Equipment

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

MISE - STEREO ENCODER

Transcription:

Cables, Feedthroughs, Detector Adapters for the mesytec MPR STM MSI Silicon Detector Electronics Series Datasheet V1.2 Cabling Collection for Silicon Detectors When using silicon (strip) detectors in an accelerator environment, a sophisticated cabling system is necessary to achieve minimum noise and optimum signal quality. Therefore the mesytec cabling collection for silicon (strip) detectors consists of three main components: - Shielded multipole cables for in- and outside the vacuum vessel - Several types of selected vacuum feedthroughs - Individually designed detector adapters Fig. 1 shows a typical setup using components from the cabling collection: Fig.1: Example for a typical setup using parts of the mesytec cabling collection for silicon detectors. 1/8

Multipole shielded cables: Outside the vacuum vesssel, excellent shielding and ground connections are of high importance for signal qualitiy. We offer a cable specially designed for the MPR preamplifier series and selected LEMO vacuum feedthroughs. Both connectors and the cable are fully shielded. Typical capacity is 30pF for 30cm total length (including connectors). The shielding is completely separated from signal ground (see figure 2 below). Fig 2: MPR-16 to feedthrough cable Fig 3: connector with feedthrough (socket-solder type) 2/8

Inside the vacuum vesssel, shielding and ground connections are also important but not as critical as outside. Vacuum compatibility and connectivity to various detector types are further issues. We offer a cable designed for the MPR preamplifier series and selected LEMO vacuum feedthroughs. The Lemo connector and the cable are shielded. To avoid large virtual leakage, shielding is only a copper mesh that s tight coupled to the connector on one side and has a ground connector on the other side. The connector on detector side is a 20 pole flat ribbon connector that can easily be matched with our individually designed detector adapters. Typical capacity is 60pF for 40cm total length (including connectors). The shielding is completely separated from signal ground and might be connected to the detector hold structure. Fig. 4 shows a cable of this type: Fig. 4: Cable for connecting detector (adapter) and vacuum feedthrough Although our standard cables are designed for the LEMO feedthroughs, we can also offer other designs on request. So please don t hesitate to contact us if you need cabling for another feedthrough. 3/8

Detector adapters: Nearly each detector brings its own specialized connector. To reuse the same standard cable for various detectors, we offer individually designed detector adapters fitting your detector and the above mentioned cable. Examples for SSDs and single pad detectors are shown in Fig. 5 and 6 below. Fig.5: Adapter for a single pad detector. Fig. 6: Adapter for a 16 strip silicon detector Adapter for Detector: Micron design "W", a 16x16 strip double sided detector. It is read out with two cable sets, and two pairs of MPR16 and STM16. Detector adapter for Micron Design "W". Right side seen on the rear side of detector (the 2 connectors to MPR16 cables visible) 1 n-side 16 Strip numbering of design "W"at STM16-output 4/8

Feedthroughs: As preferable vacuum feedthroughs we selected vacuum tight models from LEMO: For the multipole cables we selected a socket socket version (Fig. 7) for use with a plug-equipped cable on both sides and a socket solder version (Fig. 8) for use e.g. with your own cables: Fig. 7: socket-socket vacuum tight feedthrough LEMO SWH.3S.318.CLLSV Fig. 8: socket-solder version LEMO HGP.3S.318.CLLSV Pinouts: There is no pin marking on the vacuum side. Connect cable to the feedthrough and check with an Ohm meter for ground connection. 5/8

The LEMO plug connector name is FFA.3S.318.CLAC10ZN Feedthrough socket solder is HGP.3S.318.CLLSV, The feedthrough for socket-socket is SWH.3S.318.CLLSV Feedthroughs are vacuum tested, leakage rate < 10-8 mb*l/s Connection for 18 pole signal cables with vacuum feedthroughs Function MPR connector 20pole connector (until 8/2003) MPR connector Dsub25 (from 8/2003) Flat wire inside vacuum (20 pole) Signal ground 19,20 1, 7, 14,13 2,19,20 15 Channel 1 18 11 18 16 Channel 2 17 23 17 17 Channel 3 16 10 16 18 Channel 4 15 22 15 14 Channel 5 14 9 14 13 Channel 6 13 21 13 12 Channel 7 12 8 12 11 Channel 8 11 20 11 10 Channel 9 10 19 10 5 Channel 10 9 6 9 6 Channel 11 8 18 8 7 Channel 12 7 5 7 8 Channel 13 6 17 6 9 Channel 14 5 4 5 4 Channel 15 4 16 4 3 Channel 16 3 3 3 2 Signal ground 1,2 - - - guardring - 24 1 (option: NC)** 1 Lemo feedthrough ** For old mesytec design W detector adapter V1.0 wire 1 is not connected at vacuum side. 6/8

New cable type: Due to new developments, a smaller plug, socket and feeedthrough type was introduced in 2006. The cross section is reduces opening the possibility to use smaller flanges or get signals more densely packed. The LEMO plug connector is FGG.2B.319.CLAD92ZN for the outer signal cable and FGJ.2B.319.CLLD92 for the inner (vacuum suitable) signal cable. The feedthroughs are: SGJ.2B.319.CLLSV for the socket-socket type and HGG.2B.319.CLLSVfor the socket-solder type. Connection for 19 pole signal cables with vacuum feedthroughs Function MPR connector Dsub25 (from 8/2003) Flat wire inside vacuum (20 pole) Signal ground 1, 7 2 1 Channel 1 11 18 2 Channel 2 23 17 3 Channel 3 10 16 4 Channel 4 22 15 5 Channel 5 9 14 6 Channel 6 21 13 7 Channel 7 8 12 8 Channel 8 20 11 9 Channel 9 19 10 10 Channel 10 6 9 11 Channel 11 18 8 12 Channel 12 5 7 13 Channel 13 17 6 14 Channel 14 4 5 15 Channel 15 16 4 16 Channel 16 3 3 17 Signal ground 14,13 19, 20 18 guardring 24 1 19 Lemo feedthrough 7/8

How to connect the detector Sensitive lines are marked in red. Connection instructions for Micron BB7WS: 8/8