2 Contents Directory VDE Testing and 1 Description of the cable under test (CUT) Method for determining the quality of cable glands for shielded enclosures Measurement procedure Test instrumentation Measurement procedure Transfer impedance Measurement results Cable gland M/EMVD with Data Cable Transfer impedance Shielding attenuation Cable gland 5.62 M/EMVD with Data Cable Transfer impedance Shielding attenuation Cable gland 5.62 M/EMVD with Servo Cable Transfer impedance Shielding attenuation Cable gland M/EMVD with Servo Cable Transfer impedance Shielding attenuation Cable gland 5.65 M/EMVD with Servo cable Transfer impedance Shielding attenuation Double-shielded reference cables for comparison Transfer impedance Shielding attenuation Interpretation of the measurement results Evaluation of the results...26 This test report contains only the results of a single investigation carried out on the product subwithted. It is not a generally valid judgement by the VDE Testing and regarding the properties of similar products taken from current production. It does not apply to all VDE specifications applicable to the tested products. It does not entitle the applicant to use the VDE certification mark and the mark "GS = geprüfte Sicherheit (approved safety)". This test report may only be passed to a third party in its complete wording including this preamble and the date of issue. Any publication or reproduction requires the prior written approval of the VDE Testing and. File number: / (Testreport-FG doc) Page 2 of 26
3 1 Description of the cable under test (CUT) Type: Cable gland Construction: PERFECT EMC-cable gland Serial number -- Technical data: File number: / (Testreport-FG doc) Page 3 of 26
4 Used cables: The measurements were done together with cables with a braided shield or with a combined braided/foil shield as they are usually being used for the tested cable glands. For the measurements, cables with a small outer diameter were chosen as they are assumed to represent the worst case concerning the contact quality. They were also chosen for practical reasons because smaller diameters are easier to mount inside the measurement tube. The measurements were done on combinations of cable glands and cables as described in the table below (No. 1-5). In addition, two double-shielded reference cables were measured for comparison (No. 6 and 7 in the table). 1 PERFECT EMC-cable gland, M16x1,5, Art.-No M/EMVD with CC-Datenleitung LiYCY-(TP)-24, Art.-No , Manufacturer ConCab 2 PERFECT EMC-cable gland, M2x1,5, Art.-No M/EMVD with CC-Datenleitung LiYCY-(TP)-24, Art.-No , Manufacturer ConCab 3 PERFECT EMC-cable gland, M2x1,5, Art.-No M/EMVD with CC-Servo 2Y-(St)-CY-587, Art.-No , Manufacturer ConCab 4 PERFECT EMC-cable gland, M25x1,5, Art.-No M/EMVD with CC-Servo 2Y-(St)-CY-587, Art.-No , Manufacturer ConCab 5 PERFECT EMC-cable gland, M5x1,5, Art.-No M/EMVD with CC-Servo 2Y-(St)-CY-587, Art.-No , Manufacturer ConCab 6 CC-Servo 2Y-(St)-CY-587, Art.-No , Manufacturer ConCab 7 CC-Servo 2Y-(St)-CY-587, Art.-No , Manufacturer ConCab File number: / (Testreport-FG doc) Page 4 of 26
5 2 Method for determining the quality of cable glands for shielded enclosures. For the valuation of the quality of cable entry into enclosures there are no civil standards available. Therefore a military standard has been used as base. Standard: VG Teil 4 Messverfahren für geschirmte Steckverbinder (Measuring method for screened connectors) The method is modified in a way that the connector is replaced by a cable entry. The cable entry is used as a termination of the screened cable inside. The cable with the cable entry is then measured in the triaxial tube (see picture), as it is described in the VG part 4. The general method is known as the mesurement method for the transfer impedance of cables. Valuation: The different cable entry systems are intended for the use with different cable shield qualities. Therefore the valuation of the cable entry system is done allways together with a certain shielding quality of the cable. The valuation is based on the minimum disturbance of the shielding quality of the cable. The less the shielding effect of the cable is disturbed, the better the cable entry system works. 2.1 Measurement procedure The measurement is done by the following steps: 1. Assembly of the cable. 2. Mesurement of the cable without cable gland in the triaxial tube. The result of this measurement gives the quality of the used cable/shield. 3. Assembly of the cable with the cable gland according to the manufacturer s specifications. 4. Measurement of the cable with cable gland in the triaxial tube. The result of this measurement gives the quality of the used cable/shield together with the cable gland. 5. Comparison of the measurement results in a diagram. For comparison two double shielded cables without cable gland are measured as well. If the cable is used with the cable gland there should be no significant degradation of the shielding performance. 2.2 Test instrumentation The mounting of the cable gland in the measurement tube is done using an adapter piece which adapts the thread of the cable gland under test to the connection piece of the measurement tube. This connection piece has a specific inner thread (M36 STG 4 x 1,5). File number: / (Testreport-FG doc) Page 5 of 26
6 File number: / (Testreport-FG doc) Page 6 of 26
7 3 Measurement procedure 3.1 Transfer impedance General information about the test: Tested by: Gerald Gossmann Test date: /15/16 Instruments: Inventory number Description Manufacturer Type Network Analyzer R&S ZVRE 1899 Triaxial measuremend tube, thick Bedea/Rosenberger -- Information concerning the test: Test set-up: The measurement is done in the triaxial tube connected to a network analyzer. The analyzer is controlled via PC and the software WinComet version 1.3 of Bedea. The inner system consists of the cable under test (CUT) resp. of the cable gland under test with a typical shielded cable usually used for this gland. The inner leads of the CUT are soldered together on both ends. The CUT is terminated at the inner end with a 5 Ohm resistor connected to the rear ground socket inside the Shielding tube. The open end is fitted with an N-Plug. The inner system is fed by port 1 of the network analyzer. Prior to the measurement, a feed-through calibration of the used measurement cables and adapters has to be done. Further test parameters: Measurement length:.82 m; Fequency range:.1 MHz to 1 MHz; Number of points: 81; IF-BW 1 Hz; Test diagram: Next pages File number: / (Testreport-FG doc) Page 7 of 26
8 4 Measurement results 4.1 Cable gland M/EMVD with Data Cable PERFECT EMV-Cable gland, M16x1,5, Art.-No M/EMVD mit CC-Datenleitung LiYCY-(TP)-24, Art.-No , Manufacturer ConCab File number: / (Testreport-FG doc) Page 8 of 26
9 4.1.1 Transfer impedance 2 Kopplungswiderstand / Transfer impedance Kopplungswid. / Transfer imp. (Ohm/m) 1,5 1, M/EMVD mit Kabel / with cable Kabel / Cable,2 Kopplungswiderstand /Transfer impedance Kopplungswid. / Transfer imp. (Ohm/m),15,1,5,1, M/EMVD mit Kabel / with cable Kabel alleine / Cable only The diagram shows only a partial frequency range up to 1 MHz with logarithmic scaling. File number: / (Testreport-FG doc) Page 9 of 26
10 4.1.2 Shielding attenuation 1 Schirmdämpfung / Shielding attenuation Schirmdämpfung / Shielding attenuation (db) M/EMVD mit Kabel / with cable Kabel alleine / Cable only 1 Schirmdämpfung / Shielding attenuation Schirmdämpfung / Shielding attenuation (db) ,1, M/EMVD mit Kabel / with cable Kabel alleine / Cable only The diagram shows only a partial frequency range up to 1 MHz with logarithmic scaling. File number: / (Testreport-FG doc) Page 1 of 26
11 4.2 Cable gland 5.62 M/EMVD with Data Cable PERFECT EMV-Cable gland, M2x1,5, Art.-No M/EMVD mit CC-Datenleitung LiYCY-(TP)-24, Art.-No , Manufacturer ConCab File number: / (Testreport-FG doc) Page 11 of 26
12 4.2.1 Transfer impedance 3,5 Kopplungswiderstand / Transfer impedance Kopplungswid. / Transfer imp. (Ohm/m) 3 2,5 2 1,5 1, M/EMVD mit Kabel / with cable Kabel / Cable,4 Kopplungswiderstand /Transfer impedance Kopplungswid. / Transfer imp. (Ohm/m),35,3,25,2,15,1,5,1, M/EMVD mit Kabel / with cable Kabel alleine / Cable only The diagram shows only a partial frequency range up to 1 MHz with logarithmic scaling. File number: / (Testreport-FG doc) Page 12 of 26
13 4.2.2 Shielding attenuation 12 Schirmdämpfung / Shielding attenuation Schirmdämpfung / Shielding attenuation (db) M/EMVD mit Kabel / with cable Kabel alleine / Cable only 1 Schirmdämpfung / Shielding attenuation Schirmdämpfung / Shielding attenuation (db) ,1, M/EMVD mit Kabel / with cable Kabel alleine / Cable only The diagram shows only a partial frequency range up to 1 MHz with logarithmic scaling. File number: / (Testreport-FG doc) Page 13 of 26
14 4.3 Cable gland 5.62 M/EMVD with Servo Cable PERFECT EMV-Cable gland, M2x1,5, Art.-No M/EMVD mit CC-Servo 2Y-(St)-CY-587, Art.-No , Manufacturer ConCab File number: / (Testreport-FG doc) Page 14 of 26
15 4.3.1 Transfer impedance 2 Kopplungswiderstand / Transfer impedance Kopplungswid. / Transfer imp. (Ohm/m) 1,5 1, M/EMVD mit Kabel / with cable Kabel / Cable,2 Kopplungswiderstand /Transfer impedance Kopplungswid. / Transfer imp. (Ohm/m),15,1,5,1, M/EMVD mit Kabel / with cable Kabel alleine / Cable only The diagram shows only a partial frequency range up to 1 MHz with logarithmic scaling. File number: / (Testreport-FG doc) Page 15 of 26
16 4.3.2 Shielding attenuation 12 Schirmdämpfung / Shielding attenuation Schirmdämpfung / Shielding attenuation (db) M/EMVD mit Kabel / with cable Kabel alleine / Cable only 1 Schirmdämpfung / Shielding attenuation Schirmdämpfung / Shielding attenuation (db) ,1, M/EMVD mit Kabel / with cable Kabel alleine / Cable only The diagram shows only a partial frequency range up to 1 MHz with logarithmic scaling. File number: / (Testreport-FG doc) Page 16 of 26
17 4.4 Cable gland M/EMVD with Servo Cable PERFECT EMV-Cable gland, M25x1,5, Art.-No M/EMVD mit CC-Servo 2Y-(St)-CY-587, Art.-No , Manufacturer ConCab File number: / (Testreport-FG doc) Page 17 of 26
18 4.4.1 Transfer impedance 2 Kopplungswiderstand / Transfer impedance Kopplungswid. / Transfer imp. (Ohm/m) 1,5 1, M/EMVD mit Kabel / with cable Kabel / Cable,2 Kopplungswiderstand /Transfer impedance Kopplungswid. / Transfer imp. (Ohm/m),15,1,5,1, M/EMVD mit Kabel / with cable Kabel alleine / Cable only The diagram shows only a partial frequency range up to 1 MHz with logarithmic scaling. File number: / (Testreport-FG doc) Page 18 of 26
19 4.4.2 Shielding attenuation 12 Schirmdämpfung / Shielding attenuation Schirmdämpfung / Shielding attenuation (db) M/EMVD mit Kabel / with cable Kabel alleine / Cable only 1 Schirmdämpfung / Shielding attenuation Schirmdämpfung / Shielding attenuation (db) ,1, M/EMVD mit Kabel / with cable Kabel alleine / Cable only The diagram shows only a partial frequency range up to 1 MHz with logarithmic scaling. File number: / (Testreport-FG doc) Page 19 of 26
20 4.5 Cable gland 5.65 M/EMVD with Servo cable PERFECT EMV-Cable gland, M5x1,5, Art.-No M/EMVD mit CC-Servo 2Y-(St)-CY-587, Art.-No , Manufacturer ConCab File number: / (Testreport-FG doc) Page 2 of 26
21 4.5.1 Transfer impedance 2 Kopplungswiderstand / Transfer impedance Kopplungswid. / Transfer imp. (Ohm/m) 1,5 1, M/EMVD mit Kabel / with cable Kabel / Cable,2 Kopplungswiderstand /Transfer impedance Kopplungswid. / Transfer imp. (Ohm/m),15,1,5,1, M/EMVD mit Kabel / with cable Kabel alleine / Cable only The diagram shows only a partial frequency range up to 1 MHz with logarithmic scaling. File number: / (Testreport-FG doc) Page 21 of 26
22 4.5.2 Shielding attenuation 12 Schirmdämpfung / Shielding attenuation 11 Schirmdämpfung / Shielding attenuation (db) M/EMVD mit Kabel / with cable Kabel alleine / Cable only 1 Schirmdämpfung / Shielding attenuation Schirmdämpfung / Shielding attenuation (db) ,1, M/EMVD mit Kabel / with cable Kabel alleine / Cable only The diagram shows only a partial frequency range up to 1 MHz with logarithmic scaling. File number: / (Testreport-FG doc) Page 22 of 26
23 4.6 Double-shielded reference cables for comparison CC-Servo 2Y-(St)-CY-587, Art.-No , Manufacturer ConCab CC-Servo 2Y-(St)-CY-587, Art.-No , ManufacturerConCab File number: / (Testreport-FG doc) Page 23 of 26
24 4.6.1 Transfer impedance 2 Kopplungswiderstand / Transfer impedance Kopplungswid. / Transfer imp. (Ohm/m) 1,5 1, Kabel / cable Kabel / Cable Kopplungswiderstand / Transfer impedance,1 Kopplungswid. / Transfer imp. (Ohm/m),5,1, Kabel / cable Kabel / Cable The diagram shows only a partial frequency range up to 1 MHz with logarithmic scaling. File number: / (Testreport-FG doc) Page 24 of 26
25 4.6.2 Shielding attenuation 12 Schirmdämpfung / Shielding attenuation Schirmdämpfung / Shielding attenuation (db) Kabel / cable Kabel / Cable 1 Schirmdämpfung / Shielding attenuation Schirmdämpfung / Shielding attenuation (db) ,1, Kabel /cable Kabel / Cable The diagram shows only a partial frequency range up to 1 MHz with logarithmic scaling. File number: / (Testreport-FG doc) Page 25 of 26
26 4.7 Interpretation of the measurement results The evaluations must be done like this: From 3 MHz on, only the maximal values of the transfer impedance and the shielding attenuation shall be evaluated. The Minima are created by the interference of the wave fronts in the triaxial tube. Therefore the minima are caused by the measurement method and should not be counted as characteristic of the shield or cable entry. 4.8 Evaluation of the results The evaluation of the test results is considered to be an additional information and not part of the test report. The mesured cable glands have shown no significant degradation of the quality of the used and similar cable types. Therefore the measured cable glands are assumed to be suitable to lead cables into enclosures without losing the performance of the cable shield. File number: / (Testreport-FG doc) Page 26 of 26
Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness
Shielding Effectiveness Test Method Harbour s LL, SB, and SS Coaxial Cables Designs for Improved Shielding Effectiveness Harbour Industries 4744 Shelburne Road Shelburne Vermont 05482 USA 802-985-3311
Coupling/Decoupling Networks (CDN)
Coupling/Decoupling Networks (CDN) For immunity testing according to IEC / EN 61000-4-6 Immunity testing CDNs are the preferred coupling and decoupling devices, for reasons of test reproducibility and
LOW LOSS CABLE PAG. 1
LOW LOSS CABLE PAG. 1 INTRODUCTION Following many requests we received regarding the need for low-loss custom cable assemblies, we have set up a special production of high performance coaxial cable assemblies
Coupling attenuation up to 2 GHz with virtual Balun
Coupling attenuation up to GHz with virtual Balun Multiport (four-port) respectively mixed-mode VNA Bernhard Mund, Berkenhoff&Drebes GmbH, Herborner trasse 00, 3564 Asslar, Germany, [email protected], www..com
Cable Analysis and Fault Detection using the Bode 100
Cable Analysis and Fault Detection using the Bode 100 By Stephan Synkule 2014 by OMICRON Lab V1.3 Visit www.omicron-lab.com for more information. Contact [email protected] for technical support.
Standex-Meder Electronics. Custom Engineered Solutions for Tomorrow
Standex-Meder Electronics Custom Engineered Solutions for Tomorrow RF Reed Relays Part II Product Training Copyright 2013 Standex-Meder Electronics. All rights reserved. Introduction Purpose Designing
DIGITAL PC SCOPE. Total solder points: 625 Difficulty level: beginner 1 2 3 4 5 advanced K8031 ILLUSTRATED ASSEMBLY MANUAL
DIGITAL PC SCOPE Digital storage oscilloscoop, using a computer and its monitor to display waveforms. All standard oscilloscope functions are available in the Windows program supplied. Total solder points:
Crosstalk effects of shielded twisted pairs
This article deals with the modeling and simulation of shielded twisted pairs with CST CABLE STUDIO. The quality of braided shields is investigated with respect to perfect solid shields. Crosstalk effects
Research RF Sputtering Packages
Research RF Sputtering Packages Shown with 3" Polaris Adjustable Position Source with Tilt and Shutter 300 or 600 Watt Low Cost Packages for Those With Limited Budgets Desiring Full Capability 13.56 MHz
Subject: Glenair MIL-PRF 24758 Conduit Surface Transfer Impedance Test
Lothar O. Hoeft, Ph.D. Consultant, Electromagnetic Effects 5012 San Pedro Ct., NE Albuquerque, New Mexico 87109-2515 Phone: (505)-889-9705 E-mail: [email protected] 1 February 24, 2006 Subject: Glenair
Digital Active Indoor Antenna SRT ANT 10 ECO
Digital Active Indoor Antenna SRT ANT 10 ECO Picture similar User Manual Table of contents 1.0 INTRODUCTION 1 2.0 PACKAGE CONTENT 1 3.0 SAFETY NOTES 2 4.0 CONNECTING THE ANTENNA 2 1.0 INTRODUCTION Thank
Current Probes. User Manual
Current Probes User Manual ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained herein shall
Industrial circular connectors
Industrial circular connectors M 16 M 58 010 CONINVERS - M16 to M58 circular connectors for industrial applications CONINVERS GmbH, an independent company, is the specialist for M16 to M58 circular connectors
Coupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC 61000-4 - 6 and CISPR 15 / CISPR 22 IEC 61000-4 - 6
Coupling- / Decoupling Network 150 khz 300 MHz IEC 61000-4 - 6 and CISPR 15 / CISPR 22 150 khz 230 MHz IEC 61000-4 - 6 10 khz 230 MHz IEC 61000-4 - 6 and IEC 61326-3 - 2 and NAMUR Coupling and decoupling
COAX Cables Radio Frequency Cables
COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions
2. The Vector Network Analyzer
ECE 584 Laboratory Experiments 2. The Vector Network Analyzer Introduction: In this experiment we will learn to use a Vector Network Analyzer to measure the magnitude and phase of reflection and transmission
2 Ohm Nominal Coaxial Speaker OWNER S MANUAL
2 Ohm Nominal Coaxial Speaker OWNER S MANUAL 1 page 1 SPL 65 Coaxial Speaker Congratulations on your purchase of the Soundstream SPL 65 Coaxial Speaker. When used with a high quality 2 ohm rated power
EMC Basics. Speaker : Alain Lafuente. [email protected]
EMC Basics Speaker : lain Lafuente [email protected] WHT IS EMC? 2 CE Marking With the formation of the single European market, standardization was required to remove technical barriers to trade.
ENGINEERING COMMITTEE
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 02 2006 Specification for F Port, Female, Indoor NOTICE The Society of Cable Telecommunications Engineers (SCTE)
WHITEPAPER. Cable and Connector for Hiperface dsl motor drive applications
WHITEPAPER Cable and Connector for Hiperface dsl motor drive applications information for cable manufacturers Version 02 Content Information for cable manufacturers...3 Communication...3 Crosstalk & shielding...3
Times Microwave Systems Hermetically Sealed Assemblies
SCOPE This Specification details the Electrical, Mechanical and Environmental Characteristics of Times Microwave Systems MILTECH 340.34 Diameter Hermetically Sealed Coaxial Transmission Lines. This product
USB 3.0 INTERNAL CONNECTOR AND CABLE SPECIFICATION
USB 3.0 INTERNAL CONNECTOR AND CABLE SPECIFICATION Revision 1.0 August 20, 2010 2007-2010 Intel Corporation All rights reserved. Legal Disclaimers THIS SPECIFICATION IS PROVIDED AS IS WITH NO WARRANTIES
Fibre Optic Solutions for your Test and Instrumentation needs
Fibre Optic Solutions for your Test and Instrumentation needs Aerospace Test EMC/EMP Military Industrial Control High Energy Physics Automotive Test Custom www.point2point.co.uk Fibre Optic Solutions for
F Male DBS Connector Dimensional and Performance Specification
SBCA Industry Standards Subcommittee Document: SBCA Connector Recommended Practices Date of Issue: F Male DBS Connector Dimensional and Performance Specification NOTICE The Satellite Broadcasting and Communications
Selecting Receiving Antennas for Radio Tracking
Selecting Receiving Antennas for Radio Tracking Larry B Kuechle, Advanced Telemetry Systems, Inc. Isanti, Minnesota 55040 [email protected] The receiving antenna is an integral part of any radio location
Application Guide to RF Coaxial Connectors and Cables
Application Guide to RF Coaxial Connectors and Cables By: Michael J. Hannon Product Applications Engineer and Pat Malloy, Sr. Applications Engineer There is a wide variety of coaxial connectors and cables
MEASUREMENT OF TRANSFER IMPEDANCE AND SCREENING ATTENUATION EFFECTS ON CABLES USING TRI-AXIAL METHOD
International Journal on Technical and Physical Problems of Engineering (IJTPE) Published by International Organization of IOTPE ISSN 077-358 IJTPE Journal www.iotpe.com [email protected] March 01 Issue
MEASUREMENT SET-UP FOR TRAPS
Completed on 26th of June, 2012 MEASUREMENT SET-UP FOR TRAPS AUTHOR: IW2FND Attolini Lucio Via XXV Aprile, 52/B 26037 San Giovanni in Croce (CR) - Italy [email protected] Trappole_01_EN 1 1 DESCRIPTION...3
Electromagnetic (EMI) shielding
Electromagnetic (EMI) shielding 1.1. The mechanism of Electromagnetic Interference (EMI) The definition of EMC The council of the European Union defines EMC in Article 4 of their "council directive on
Cabling Collection for Silicon Detectors
Cables, Feedthroughs, Detector Adapters for the mesytec MPR STM MSI Silicon Detector Electronics Series Datasheet V1.2 Cabling Collection for Silicon Detectors When using silicon (strip) detectors in an
HARTING Ethernet Cabling 4-poles Overview
Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] HARTING PushPull Connectors [on page 22] System cables [on page 24] Panel feed-throughs [on
Outdoor Carrier Class Shielded Ethernet Cable. Datasheet. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof
Datasheet Outdoor Carrier Class Shielded Ethernet Cable Models: PRO, CARRIER, Connectors Increase Performance Extreme Weatherproof ESD Damage Protection Extended Cable Support 1 2Datasheet Protect your
FN2001-A1 Network module (SAFEDLINK) Mounting Installation
FN00-A Network module (SAFEDLINK) Mounting Installation A6V050_f_en_-- 05-0-6 Building Technologies Division Legal notice Legal notice Technical specifications and availability subject to change without
Coaxial Cables for Medium-Frequency Applications
Coaxial Cables for Medium-Frequency Applications Coaxial Cables for Medium-Frequency Applications Introduction Telecommunications technology is moving forward rapidly and the need for fast and reliable
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 123 2011
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 123 2011 Specification for F Connector, Male, Feed-Through NOTICE The Society of Cable Telecommunications Engineers
LOXONE 12 Channel Amplifier
LOXONE 12 Channel Amplifier Item no.: 200110 Thank you for purchasing the Loxone Twelve Channel Amplifier. The versatility of the Amplifier makes it the perfect choice for almost every type of custom multi-room
SICK AG WHITEPAPER. Information for cable manufacturers Note-2_03
SICK AG WHITEPAPER Cable and connector for HIPERFACE DSL motor drive applications Information for cable manufacturers Note-2_03 Juergen Funkhaenel Application Engineer at SICK STEGMANN GmbH Donaueschingen
1394 locking cables. Your locking cables for AVT IEEE 1394 cameras
Your locking cables for AVT IEEE 1394 cameras AVT locking cables are ideal for connection of IEEE 1394 cameras in any industrial application. The high quality cables guarantee low damping and best signal
DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD OF INSERTION LOSS MEASUREMENT
INCH-POUND MIL-STD-220C 14 May 2009 SUPERSEDING MIL-STD-220B 24 January 2000 DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD OF INSERTION LOSS MEASUREMENT AMSC N/A FSC EMCS FOREWORD 1. This standard
SMA Connectors. RF Coax Connectors. Product Facts
SMA Connectors Product Facts Performance to 12.4 GHz and beyond Available in various base metal options, including stainless steel, brass and zinc diecast Uses industry standard crimp tools and processes
Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.
ACS-101 Amplified Broadband UHF Combiner-Splitter General Description The ACS-101 (Antenna Combiner Splitter 10 to 1) is an amplified and filtered broadband splitter-combiner. It allows up to 10 base stations
Section 2.0 : Construction and Measurement of a Simple Test Transmission Line
Section 2.0 : Construction and Measurement of a Simple Test Transmission Line After deciding to use a Focal 8V 4412 mid-bass driver for my first transmission line design, I started looking for a simple
PC FUNCTION GENERATOR
PC FUNCTION GENERATOR Create standard signal waves like e.g. sine, triangle and rectangle are available; other sine waves can be easily created with integrated software. Total solder points: 954 Difficulty
PicoScope 6000A/B Series
PicoScope 6000A/B Series PC Oscilloscopes User's Guide -1 PicoScope 6000A/B Series User's Guide I Contents 1 Welcome...1 2 Introduction...2 1 Using this guide 2 Safety symbols 3 Safety warnings 4 FCC
Balun Parameter Definitions & Measurement May 2004
Balun Parameter Definitions & Measurement May 2004 Differential circuits are becoming more widely used in RF circuits for the same reason that they have been used for years in lower frequency circuits.
TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD
Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall
Analysis of the G3LTF Dual Band Feed for 23cm and 13cm Paul Wade W1GHZ 2004 [email protected]
Analysis of the G3LTF Dual Band Feed for 23cm and 13cm Paul Wade W1GHZ 2004 [email protected] In the March 2004 edition of the RSGB Microwave Newsletter, G3LTF described 1 a dual band feed for the 23 cm and
Installing Cisco TelePresence MX200 G2 - Wheel Base
This installation guide covers MX200 G2 with a wheel base. Dimensions Height: 1480 mm / 58.3 in. Width: 995 mm / 39.2 in. Depth: 715 mm / 28.0 in. Weight total: 33 kg / 73 lb Weight monitor: 24 kg / 53
Installation instruction do88 Intercooler for Volvo S40 / V50 / C30
Installation instruction do88 Intercooler for Volvo S40 / V50 / C30 This instruction shows how to replace the OEM intercooler with our performance intercooler. 2. 3. 1. 4. 5. Part number: ICM-170 6. At
Vector Network Analyzer Techniques to Measure WR340 Waveguide Windows
LS-296 Vector Network Analyzer Techniques to Measure WR340 Waveguide Windows T. L. Smith ASD / RF Group Advanced Photon Source Argonne National Laboratory June 26, 2002 Table of Contents 1) Introduction
IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions
IMMS-CCC IMMS-CCC Hardwire Central Interface Installation Instructions TABLE OF CONTENTS... Choose a Location... 1 Connections... 2 Operations... 3 Software Configuration... 4 Troubleshooting... 5 Loopback
Required Supplies for Installing Check Tag Assembly
Check Tag Assembly and Antenna Installation Instructions 411922-004 05/10 This document explains how to install and connect the check tag assembly and check tag antenna. Required Supplies for Installing
Weekend Antennas No. 1 A Bobtail Curtain for 2m
Weekend Antennas No. 1 A Bobtail Curtain for 2m Welcome to the first installment of my new column, which I hope will become a regular feature in Radio ZS. Each installment will present a practical and
NATIONAL TYPE MB-40SL MULTI-BAND TANK 9/29/1953
NATIONAL TYPE MB-40SL MULTI-BAND TANK 9/29/1953 1. GENERAL The MB-40SL tanks is intended for use in grid circuits with approximately 20 Watts input and in final plate tank circuits of transmitters when
MACTek Corporation. USB HART Interface. Users Manual
MACTek Corporation USB HART Interface DM01003100AA February, 2003 LIMITED WARRANTY VIATOR Interface for HART MACTek Corporation warrants this Interface and all of its component against defects in materials
Differential Charge Amplifier
Electronics Differential Type 58A... The differential charge amplifier is used for signal conversion of piezoelectric sensors with differential output. Executions Aluminum die-cast enclosure (IP64) Plastic
PROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info
RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals
A Study of RF Absorber for Anechoic Chambers Used in the Frequency Range for Power Line Communication System
538 Progress In Electromagnetics Research Symposium 2006, Cambridge, USA, March 26-29 A Study of RF Absorber for Anechoic Chambers Used in the Frequency Range for Power Line Communication System K. Shimada
Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2 www.akitio.
Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.2 www.akitio.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 Technical Specifications...
SHEET 5 CABLE TELEVISION SYSTEM
SHEET 5 CABLE TELEVISION SYSTEM TRADITIONAL TELEVISION AND IPTV INTRODUCTION Access to full digital, as an inevitable technological development, clearly demonstrates the place of Digital Communication
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273
Bi-Directional Amplifier Systems
Bi-Directional Amplifier Systems Installation and Operation Manual Model Series 850622 EMR CORPORATION 17431 N. 25th Ave. Phoenix, AZ 85023 Emails: [email protected] Phone: (623) 581-2875 Toll-Free: (800)
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
BUILDING INSTRUCTIONS
etap2hw 38 mm I2C to LCD Interface BUILDING INSTRUCTIONS October 2013 P. Verbruggen Rev 1.01 15-Oct-13 Page 1 Table of Contents Chapter 1 General Information 1.1 ESD Precautions 1.2 Further Supplies 1.3
EH-20 20m antenna. By VE3RGW
EH-20 20m antenna By VE3RGW Equivalent circuit of EH-20 (prototype 2A) antenna system. Upper cylinder Lower cylinder Ground Counter pose Phasing coil Impedance transformer and tune circuit Tune coil Feed
14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. [email protected] - 800-843-9859 - www.powermation.
14 PHOENIX CONTACT PLUSCON circular is a circular connector for use in industrial automation. The range of design sizes available is varied, starting with the design sizes M5 to M8 and M1, for sensor/actuator
MRC High Resolution. MR-compatible digital HD video camera. User manual
MRC High Resolution MR-compatible digital HD video camera User manual page 1 of 12 Contents 1. Intended use...2 2. System components...3 3. Video camera and lens...4 4. Interface...4 5. Installation...5
HPM-5 Performance Testing
HPM-5 Performance Testing Test 234 JF Sawdy 7/3/02 Samples: Double-ended 2mm cable assemblies: 3, 6 and 8 meters end-to-end, using Meritec s 700219-01 28 awg twinax cable and Meritec s HPM-5 connectors
CCTV System Troubleshooting Guide
Wouldn t be nice to start and finish a CCTV System Project without running into any problems before, during and after the installation is completed. Well, in this article we will try and explain why we
Siemens Energy & Automation. structured. WIRING Product Training Series: Advanced Video Session 3
s structured WIRING Product Training Series: Advanced Video Session 3 1 Table of Contents This presentation will give you a closer look at Video in Structured Wiring applications. The following Areas will
Wideband Active Loop Antenna Amplifier with Passive Augmentation
Wideband Active Loop Antenna Amplifier with Passive Augmentation Transformer T1 is the inline transmission line current transformer, described on the next page. Transformers T2 and T3 are the augmentation
EVOline Multimedia Modules
243 EVOline VGA cable EVOline DVI-A cable EVOline DVI-D cable EVOline HDMI cable Cable properties Flame retardant self extinguishing VW-1 Halogen free yes yes yes Colour Black Black Outer diameter 7,2
CoaXPress White Paper WP-2: Cabling Solutions
White Paper Authors Chris Beynon, Active Silicon Ltd Jochem Hermann, Adimec Advanced Image Systems BV Edited By Chris Beynon, Active Silicon Ltd Revision 1.0 27 November 2009 White Paper 1 Introduction...
400 Series Buccaneer BUCCANEER POWER. bulgin
bulgin BUCCANEER FOR POWER Contact Retainer Sealing Gasket O Ring Contacts Locking Ring Retaining Nut Panel Body Contacts Contact Carrier O Ring Main Body Cable Gland Collet Gland Nut Sealed to IP68 when
PCIe XMC x8 Lane Adapter
Adapts PCI Express XMC to Desktop with P16 High Speed Communications Ports and JN4 Digital IO FEATURES Adapt one XMC PCI Express VITA 42.3 module to a desktop PCI Express slot Supports up to 8 lanes Transparent
Cond-IS RF Conducted Immunity System
Cond-IS RF Conducted Immunity System About RF Conducted Immunity In the global contest of EMC testing for residential and industrial EUTs (Equipments Under Test) RF Conducted Immunity compliance verification
Switch board datasheet EB007-00-1
Switch board datasheet EB007-00-1 Contents 1. About this document... 2 2. General information... 3 3. Board layout... 4 4. Testing this product... 5 5. Circuit description... 6 Appendix 1 Circuit diagram
Turbo X. www.smartwireless.co.uk. 594 channel UHF true diversity
Turbo X 594 channel UHF true diversity The new Turbo X series from Smart Wireless is the culmination of two years of research and development into advanced wireless technology. Using sophisticated RF design
Contents. Safety Warnings... 1
Contents Safety Warnings... 1 Unpacking the GQ600... 1 Introduction... 2 GQ600 Filter Characteristics... 2 1/3 Octave Centre Frequencies... 4 Front Panel Functions... 5 Rear Panel Functions... 6 Specifications...
SB-1000 Link-All-3.0 USB Radio interface Operating Manual CG Antenna Co. Ltd.
CG Antenna SB-1000 Link-All-3.0 USB Radio interface Operating Manual CG Antenna Co. Ltd. Shanghai, China - 1 - http://www.cgantenna.com FEATURES Connect your computer with USB port. No need serial or parallel
USB to RS-422/485 Serial Adapter
USB to RS-422/485 Serial Adapter User Manual Ver. 2.00 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction... 3 1.2
COAXICON Contacts. RF Coax Connectors. Product Facts
COXICON Contacts Product Facts Tyco Electronics provides a variety of contacts for coaxial connectors Contacts are available in a range of sizes that may be used with the various types of coaxial cable
Taurus - RAID. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. User Manual
Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives User Manual v1.0 August 23, 2007 EN Table of Contents CHAPTER 1 - INTRODUCTION 1 CHAPTER 3 - SYSTEM SET UP 9 ICON KEY 1 THE TAURUS RAID 1 AVAILABLE
TFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB
Type: TU6T60-JVB Dielectric 2nd Outer (w/optional Floodant) Series 6 Coaxial Cable Copper Clad Steel Foamed Polyethylene Dielectric Bonded AP Laminate Shield 60% Aluminum Braid "Life Time" compound AP
PERF10 Rubidium Atomic Clock
Owner s Manual Audio Stanford Research Systems Revision 1.0 February, 2011 2 Certification Stanford Research Systems certifies that this product met its published specifications at the time of shipment.
Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection
Cable Guide Cables, Connectors & Tools for installation of quality networks TRIAX - your ultimate connection A Selection of the best Triax TX Cable range optimised for digital reception Simplification
Flexible PCB Antenna with Cable Integration Application Note Version 2
Flexible PCB Antenna with Cable Integration Application Note Version 2 CONTENTS 1. BASICS 2. APPLICATIONS 3. SIZE 4. SHAPE 5. GROUND PLANE SIZE 6. IMPEDANCE 7. BANDWIDTH 8. VSWR 9. GAIN 10. EFFICIENCY
IF MATRIX SWITCH FOR THE 40 METER RADIO TELESCOPE
IF MATRIX SWITCH FOR THE 40 METER RADIO TELESCOPE David Cuadrado Calle, José Antonio López Pérez INFORME TÉCNICO - CAY 2012-8 Marzo 2012 INDEX 1. Introduction... 2 1.1 Current system... 2 1.2 Justification
R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements
R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements on telecommunications ports Test & Measurement Data Sheet 01.00 R&S ENY81-CA6 Coupling Network At a glance The R&S ENY81-CA6
EMC Test Chamber Solutions RF Cable Assemblies and Connectors
EMC Test Chamber Solutions RF Cable Assemblies and Connectors RF CABLE ASSEMBLY AND CONNECTOR SOLUTONS FOR EMC MMUNTY AND EMSSON COMPLANCE TESTNG E X T N T R A T E D E P T H --> POWER LEVEL: -40.00 dbm
Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W
14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar Network Analyzer combines a 90 db wide dynamic range with the accuracy and linearity
MABINDRA RAI THE INVESTIGATION OF MINIVNAPRO VECTOR NETWORK ANALYZER
MABINDRA RAI THE INVESTIGATION OF MINIVNAPRO VECTOR NETWORK ANALYZER Information Technology 2015 ACKNOWLEDGEMENTS I would like to thank M.Sc Jani Ahvonen, M.Sc Santiago Chavez and M.Sc Antti Virtanen for
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN
Uniprise Solutions COAX 101. White Paper. www.commscope.com
Uniprise Solutions COAX 101 White Paper www.commscope.com Structured cable systems have very thorough standards for fiber optic and twisted pair installations. The cabling components and installed systems
UCC 1 USB-CAN CONVERTER
Owner s Manual UCC 1 USB-CAN CONVERTER Contents 1. Description... 17 2. Controls and Connections... 18 3. Installation... 19 3.1 Unpacking... 19 3.2 Rack-Mounting... 19 4. Initial Operation... 20 4.1 PC
RF cables. Edition 2015
RF cables Edition 2015 Developed for highest expectations Your partner for system solutions HUBER+SUHNER is a leading international producer and supplier of electrical and optical interconnectivity components
Line Level Converter Box. S Class Signal Processors
Line Level Converter Box S Class Signal Processors Table Of Contents Introduction and Features 3 Front and Rear Panel Layout 4 Operating the S convert Using the LEVEL controls 5 Typical Set-up 6 Wiring