final corrected draft



Similar documents
EVALUATING ASTIGMATISM

JRS Standard for Reporting Astigmatism Outcomes of Refractive Surgery

Standardized Analyses of Correction of Astigmatism With the Visian Toric Phakic Implantable Collamer Lens

Incision along Steep Axis

KERATOCONUS IS A BILATERAL, ASYMMETRIC, CHRONIC,

Phacoemulsification: Considerations for Astigmatism Management Jason P. Brinton, MD and Thomas A. Oetting, MS, MD June 10, 2011

What is the main target for all phaco surgeons?

IOL Calculation After LASIK. Chapter (3)


AcrySof IQ Toric IOL (SN6ATT) Surgeon Keys for Success & Acknowledgement

Keratoconus Detection Using Corneal Topography

What are your options for correcting astigmatism?

Management of Astigmatism in Cataract Surgery

A STUDY ON SURGICALLY INDUCED ASTIGMATISM FOLLOWING SMALL INCISION CATARACT SURGERY

Astigmatism and vision: Should all astigmatism always be corrected? 1 Ophthalmic Research Group, Aston University, Birmingham, UK

Posterior Corneal Astigmatism: Is It Important? MP Weikert, MD Baylor College of Medicine October 23, 2011

Customized corneal ablation can be designed. Slit Skiascopic-guided Ablation Using the Nidek Laser. Scott MacRae, MD; Masanao Fujieda

Clinical Study Minimizing Surgically Induced Astigmatism at the Time of Cataract Surgery Using a Square Posterior Limbal Incision

Management of Corneal Astigmatism by Limbal Relaxing Incisions during Cataract Surgery

Bitoric Laser In Situ Keratomileusis for the Correction of Simple Myopic and Mixed Astigmatism

FIRST EXPERIENCE WITH THE ZEISS FEMTOSECOND SYSTEM IN CONJUNC- TION WITH THE MEL 80 IN THE US

Lasik Xtra in: Hyperopia AK Xtra Clear cornea cataract surgery

EUROPEAN JOURNAL OF PHARMACEUTICAL AND MEDICAL RESEARCH

CORNEAL TOPOGRAPHY. Refractive power of the eye

ABrand New Refraction Meas urement Instrument

Calculation of intraocular lens (IOL) power for

Uncorrected astigmatism can cause visual

Kerry D. Solomon, MD, is Director of the Carolina Eyecare Research Institute at Carolina Eyecare Physicians in Charleston, S.C.

Refractive Surgery. Common Refractive Errors

Simple regression formula for intraocular lens power adjustment in eyes requiring cataract surgery after excimer laser photoablation

Residents Research Forum

NEW HORIZONS IN CORNEAL SURGERY VERSATILE FEMTOSECOND LASER WORKSTATION WE FOCUS ON PERFECTION

Pseudophakic Residual Astigmatism

INTRODUCTION. Trans Am Ophthalmol Soc 2006;104:

Case Reports Post-LASIK ectasia treated with intrastromal corneal ring segments and corneal crosslinking

Active Cyclotorsion Error Correction During LASIK for Myopia and Myopic Astigmatism With the NIDEK EC-5000 CX III Laser

Optimizing outcomes with toric IOLs

Course # Intra Corneal Ring Segments Contact Lens Management of Irregular Astigmatism

Curtin G. Kelley, M.D. Director of Vision Correction Surgery Arena Eye Surgeons Associate Clinical Professor of Ophthalmology The Ohio State

OMNI EYE SPECIALISTS. The Intraocular Lens

Wavefront technology has been used in our

To date, several million patients have been treated worldwide. So why not discover the benefits The Eye Hospital can bring to your life.

IOL Power Calculation After Myopic LASIK. Hany Helaly, Lecturer of Ophthalmology, Faculty of Medicine, Alexandria University.

IBRA Professional. Leading Technology for Refractive Outcome Analysis. Brochure 2015

Managing Astigmatism in your Cataract Practice

Comparison of Corneal Power and Intraocular Lens Power Calculation Methods after LASIK for Myopia. Abstract

Total Corneal Power Estimation: Ray Tracing Method versus Gaussian Optics Formula PATIENTS AND METHODS

Quality Control in Refractive Surgery

The future of laser refractive surgery is exciting

Our Commitment To You

IOL Power Calculations for Postrefractive Surgery Eyes

COMPARISON OF INTRAOCULAR LENS POWER CALCULATION METHODS IN EYES THAT HAVE UNDERGONE LASER-ASSISTED IN-SITU KERATOMILEUSIS

Refractive Errors. Refractive Surgery. Eye Care In Modern Life. Structure of the Eye. Structure of the Eye. Structure of the Eye. Structure of the Eye

Eye Care In Modern Life

Supplement to October Master Your Toric Planning and Improve Refractive Outcomes With the LENSTAR LS 900. Sponsored by

Laser refractive surgery is becoming increasingly

Refractive Surgery. Evolution of Refractive Error Correction

Optimizing refractive outcomes

5/24/2013 ESOIRS Moderator: Alaa Ghaith, MD. Faculty: Ahmed El Masri, MD Mohamed Shafik, MD Mohamed El Kateb, MD

Topographically-guided Laser In Situ Keratomileusis to Treat Corneal Irregularities

How To Implant A Keraring

articles Intraocular lens power calculation after corneal refractive surgery: Double-K method Jaime Aramberri, MD

Life Science Journal 2014;11(9) Cross cylinder Challenging cases and their resultswith Nidek Quest (EC-5000)

OCT-based IOL power calculation for eyes with previous myopic and hyperopic laser vision correction

refractive surgery a closer look

Physics 1230: Light and Color

How do we use the Galilei for cataract and refractive surgery?

Corneal Power Measurements Using Scheimpflug Imaging in Eyes With Prior Corneal Refractive Surgery

Providing Optimal Optics For Your Astigmatic Cataract Patients. While the cornea remains relatively stable and prolate throughout life

THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening

Excimer Laser Photorefractive Keratectomy for Keratoconus

The Toric Solution: Exceeding Expectations in Patients with Astigmatism. Saturday 5 October XXXI Congress of the ESCRS Amsterdam, The Netherlands

Femtolaser and ocular surgery

Wavefront Analysis in Post-LASIK Eyes and Its Correlation with Visual Symptoms, Refraction, and Topography

Astigmatism in cataract surgery

Customized corneal ablation and super vision. Customized Corneal Ablation and Super Vision

LASER VISION C ORRECTION REFRACTIVE SURGERY CENTER

the corneal incision s role in the apparition of

Comparison Combined LASIK Procedure for Ametropic Presbyopes and Planned Dual Interface for Post-LASIK Presbyopes Using Small Aperture Corneal Inlay

VISX Wavefront-Guided LASIK for Correction of Myopic Astigmatism, Hyperopic Astigmatism and Mixed Astigmatism (CustomVue LASIK Laser Treatment)

SCHWIND CAM Perfect Planning wide range of applications

Insert to October 2013 THE COMPLETE PICTURE. Experiences with the ALADDIN system. Sponsored by Topcon

Dr. Booth received his medical degree from the University of California: San Diego and his bachelor of science from Stanford University.

Cataract Surgery after Myopic Refractive Procedures. Ray Guard Eye Center Huang Wei-Jen, MD

Transcription:

Archived at the Flinders Academic Commons http://dspace.flinders.edu.au/dspace/ This is the author s final corrected draft of this article. It has undergone peer review. Citation for the publisher s version: Publisher s website: http://www.elsevier.com/wps/find/journaldescription.cws_home/620025/description#description Citation: Goggin M. Pesudovs K. Assessment of surgically induced astigmatism: toward an international standard. Journal of Cataract & Refractive Surgery. 24(12):1548-50, 1998 Dec.

Astigmatism reporting standard 1 Assessment of surgically induced astigmatism: toward an international standard Michael Goggin FRCSI(Ophth) Konrad Pesudovs FAAO. Adelaide, Australia. Address for Correspondence Konrad Pesudovs, Flinders University Dept. of Ophthalmology, Flinders Medical Centre, Bedford Park, South Australia 5042. Australia.

Astigmatism reporting standard 2 Central regular corneal astigmatism can be described, in empirical topographical terms, as a dome with an elliptical base. By definition, the elliptical base has a long axis and a short axis at right angles to each other. Astigmatism is commonly described by the difference between the curve of the dome on the long axis and on the short axis and the direction of one axis. Surgery for astigmatism alters the dome by changing the elliptical base or alters the dome, itself. This is a simple concept so why is it so difficult to describe the changes brought about by surgery in terms of optical astigmatism? Some of the difficulties arise due to historical ways of describing astigmatism and others from the assumptions of first order optics. These difficulties can be characterised in the following way: 1. The description of astigmatism on the basis of the hemimeridia of the superior cornea, i.e. the 0 0 to 180 0 description of axis. This assumes that the two hemimeridia on each axis are symmetrical while providing a duplication of descriptive terms for the horizontal meridian. 2. Astigmatism can be legitimately described in refractive, conventional keratometric and videokeratoscopic terms. Furthermore, some authors describe refractive astigmatism in terms of spectacle correction and others make corrections to the corneal plane. 3. Differing cylinder sign conventions describe the same shape. 4. The derivation of corneal curvature values from keratometry relies on assumptions of paraxial optics that are not applicable in the mid and far-periphery of the cornea. 5. Since the outcome of astigmatic correction depends on the axis as well as the magnitude of the toric change, and magnitude can be effected by axis variation and vice versa, vector analysis is necessary to examine the changes that take place in the cornea with surgery.

Astigmatism reporting standard 3 For ease of reporting and comparability of results we should pick, where possible, standard values from those parameters that have alternate descriptors or at least state clearly the conventions being used. For example, to facilitate comparison between refractive and corneal measures of astigmatism, refractive errors should be analysed at the corneal plane. However, imposing standard methods of recording data like this, or insisting on one cylinder sign convention (another example where practices are entrenched) may prove difficult and is, perhaps, less pressing than standardisation of methods of analysis of data. So, in response to the standard for assessment and reporting of data on surgically induced astigmatism (SIA) suggested by Naeser, (1) we would like to propose a simpler approach. It would appear that there are two types of analysis of SIA. Firstly, analysis of a particular intervention with regard to its effect on astigmatism, but where the intervention is not necessarily intended to reduce cylinder power. Examples of this would be the SIA of cataract wound incisions or spherical PRK. The second is analysis of SIA where the specific intent of the surgery is to alter (usually reduce) astigmatism in a predictable manner with regard to axis and cylinder power, e.g. toric excimer treatments or arcuate keratotomy. The methods of analysis, as Naeser pointed out, need to be sufficiently robust to allow for analysis of individual cases and aggregate data. (1) The important features of the analysis depend on the outcome measure of interest. For instance, if visual outcome, alone, is of interest, then the absolute magnitude of the remaining cylinder is more important than its axis. Simple data on remaining astigmatism or cylinder subtraction analysis may be enough to describe the outcome for that purpose. Alternatively, if the impact of surgery on

Astigmatism reporting standard 4 corneal shape is of interest then vector analysis is required. Additionally, if one has a specific aim for the intervention, then measurement of success or failure and analysis of how to improve outcome require the setting of a target as described by Alpins. (2) Analysis of SIA where the intent is not necessarily to reduce cylinder power. For this form of analysis, three things need to be elucidated. 1. (e.g. cataract surgery). In the simplest terms, this requires measurements before and after surgery on that axis and simple comparison of magnitude or power. Aggregate data could be analysed by mean, standard deviation and comparisons made by whatever tests of significance were appropriate. As an alternative to direct measurement, these data can be derived by vector analysis from pre- and post-operative corneal astigmatism values, and the surgical axis. Alpins has described such techniques. (3) Curvature change at any meridian in the cornea can be derived by vector analysis to give the flattening, steepening and torque (or axis shift, free of magnitude change) that has taken place. 2. Magnitude and direction can be derived by whatever method is felt most appropriate. (2,4) This kind of analysis is necessary to examine the change in astigmatism brought about by treatments that effect all axes simultaneously (if not equally), like spherical PRK. Alternatively, comparison of direction with a surgical meridian, e.g. a cataract wound, can be undertaken by assigning a plus or minus sign to the direction of misalignment of the SIA with the meridian where the surgery was performed. Usually, this would involve assigning a plus for SIA placed anticlockwise to the site of surgery and a minus for that placed clockwise. Subtracting the

Astigmatism reporting standard 5 surgical axis from the SIA axis, using the 180 0 axis convention and zero rather than 180 0 to describe the horizontal meridian, will yield such signs. A measure of the accuracy of alignment would then be the standard deviation of a mean of a number of observations. 3.. Of course, this form of analysis gives us no information on surgical events in the cornea; vector analysis is necessary for that. However, since, for higher cylinder powers, the effect on the patient s vision is governed more by the power of the astigmatism than the axis, this kind of analysis is important in terms of visual outcome These methods could also be used to describe corneal curvature changes induced by disease or injury. Analysis of SIA where the intent is to alter (usually reduce) cylinder power. The crucial elements in this sort of analysis are the setting of a target and analysis of how the SIA fits with the targeted induced astigmatism (TIA). (2) This step allows measurement of degrees of success and modification of subsequent surgery to improve results. Without a target we have no method of assessing whether we have achieved the desired result. The standard for reporting proposed by Naeser lacks such a target. (1) Even if the target remaining astigmatism is always zero, the change required in each case to achieve this must be given a numerical value to allow analysis of degrees of over-treatment, under-treatment or misalignment. For a sample of eyes, the mean SIA, where each eye has a different pre-operative and post-operative

Astigmatism reporting standard 6 astigmatism, has little meaning. However, the proportion of the astigmatic target achieved (Alpins Correction Index (SIA/TIA) or its inverse, the Co-efficient of Adjustment) facilitates modification of subsequent treatments. (2,5) To accomplish this, obviously a SIA and a TIA need to be derived, each with direction and magnitude. The question as to how well these derived values coincide can then be addressed in individuals and in aggregate data. Alpins suggests a number of indices of accuracy and outcome based on the SIA, TIA and torque vectors. (2,3,5,6,7) Analysis of aggregate direction data, comparing SIA with TIA, using the sign method described above, deriving means and standard deviations, allows us to assess the accuracy of axis placement of treatment, Alpins Angle of Error. (2) Well placed treatments will have differences between SIA orientation and TIA orientation near zero and small standard deviations on the mean. The minimum data that should be reported, to allow most of these analyses, are the SIA and TIA vector magnitudes and orientations. For this kind of surgery, where residual surgical astigmatism power should approach zero (i.e. where SIA should equal TIA), the axis of remaining astigmatism becomes more important. In fact, it may be desirable to leave, in selected cases, with-the-rule myopic astigmatism for its putative benefits for near visual acuity. In these circumstances, cylinder subtraction analysis becomes less meaningful. However, where large cylinder power may remain after surgery (for example, following refractive surgery for post-keratoplasty astigmatism) it is probably worth reporting remaining astigmatism because of the impact on visual outcome.

Astigmatism reporting standard 7 We would argue that, in using vector analysis, we combine the numerical descriptors of astigmatism (cylinder power and axis) in a unified mathematical expression (a vector with magnitude and direction), allowing us to calculate astigmatic change in terms of power / magnitude and axis / direction, where these two values vary in an inter-dependent way. This then allows us to look at each of the two values independently. The key to analysis of aggregate data lies, then, in the comparison of achieved surgical effect to a target since, as Naeser points out, (1) analysis of surgical effect alone is often meaningless. In summary, the following minimum data set should be reported in studies of the changes in astigmatism brought about by surgery. For analysis of astigmatic change where the intent is not necessarily to reduce cylinder power: 1. Pre-operative refractive or keratometric measurements. 2. The surgical axis, where one exists. 3. Pre-operative corneal curvature on that surgical axis. 4. Post-operative corneal curvature on that surgical axis. 5. Post-operative refractive or keratometric measurements. 6. SIA, magnitude and direction. For analysis of SIA where the intent is to alter cylinder power and /or axis: 1. Pre-operative refractive or keratometric measurements. 2. The surgical axis. 3. The target astigmatism to remain after surgery (axis and magnitude).

Astigmatism reporting standard 8 4. Post-operative refractive or keratometric measurements. 5. SIA magnitude and orientation. 6. TIA magnitude and orientation. From this data set, various indices of outcome can be derived. For more comprehensive reporting, Alpins has described methods for vector analysis appropriate for almost all forms of astigmatic change. (2,3,5)

Astigmatism reporting standard 9 References. 1. Naeser K. Assessment of surgically induced astigmatism; call for an international standard. J Cataract Refract Surg 1997; 23: 1278-1280 2. Alpins NA. A new method of analyzing vectors for changes in astigmatism. J Cataract Refract Surg 1993; 19: 524-533. 3. Alpins NA. Vector analysis of astigmatism changes by flattening, steepening and torque. J Cataract Refract Surg 1997; 23: 1503-1514 4. Holladay JT, Cravy TV, Koch DD. Calculating the surgically induced refractive change following ocular surgery. J Cataract Refract Surg 1992; 18: 429-443. 5. Alpins NA. A new method of targeting vectors to treat astigmatism. J Cataract Refract Surg 1997; 23: 65-75. 6. Goggin M, Kenna P, Lavery F. Photoastigmatic refractive keratectomy for compound myopic astigmatism. J Refract Surg 1997, 13: 162-166. 7. Danjoux JP, Fraenkel G, Lawless MA, Rodgers C. Treatment of myopic astigmatism with the Summit Apex Plus excimer laser. J Cataract Refract Surg 1997; 23: 1472-1479. The authors have no proprietary interest in the subject matter.