IOL Power Calculations for Postrefractive Surgery Eyes
|
|
|
- Coral Dawson
- 10 years ago
- Views:
Transcription
1 eyetube.net The Creator s Forum: IOL Power Calculations for Postrefractive Surgery Eyes Olsen Formula By Thomas Olsen, MD, PhD The calculation of IOL power in an eye that has undergone corneal refractive surgery is not a straightforward task. However, if you understand why the calculation may go wrong, you will have a fair chance of getting a good result using modern technology. It is important to understand that the calculation errors of post-lasik eyes are the sum of the traditional errors plus the errors associated with the abnormal corneal shape. The post-lasik eye exposes some of the weaknesses of the traditional IOL power calculation formulas. ERRORS OF TRADITIONAL FORMULAS Many of the old thin-lens IOL power calculation formulas, such as the Binkhorst, Hoffer Q, Holladay 1, and SRK/T use only the K reading and the AL as input. 1 When these formulas are used in post-lasik cases, two problems occur. Problem No. 1. The flatness of the K reading makes the formula believe the ELP is more anterior than it really is. With a shallow ELP, the formula will predict a low IOL power, causing a hyperopic surprise. Figure 1 explains Fyodorov s concept of the corneal height, which is the ELP principle of the SRK/T and the Holladay 1 formulas. Problem No. 2. A simple K reading measures only the curvature of the anterior surface of the cornea. However, most keratometers calculate the power according to the formula K = ( )/r, where r is the anterior radius in meters and is the fictitious refractive index of the cornea, as if the cornea were a thin lens. Therefore, in order for the anterior curvature measurement to be translated into the true power of the cornea, the following must be calculated: the curvature of the posterior surface, the corneal thickness, and the true refractive index of the cornea (1.376). In normal corneas, it is reasonable to assume that there is a constant ratio (called the Gullstrand ratio from the Gullstrand exact schematic eye) between the anterior and posterior curvatures. For the post-lasik cornea, however, the Gullstrand ratio is reduced, and the keratometerreported K reading will overestimate the true corneal power. Again, the formula will think the IOL power should be reduced, and the patient ends up with a hyperopic error. Modern Scheimpflug imaging and other tomography techniques provide more insight into the variation of the Gullstrand ratio in normal and post-lasik eyes. Figure 2 shows the results of Pentacam (Oculus Optikgeräte GmbH) measurement of the anterior and posterior corneal curvatures, giving the distribution of the Gullstrand ratio in a normal population and in a post-lasik population (average ablation, D). The reduction of the Gullstrand ratio is dependent on the amount of laser ablation (Figures 3 and 4). For example, if the Gullstrand ratio is 0.7 (ie, as a result of a 7.00 D ablation; Figure 3), the difference between the true corneal power and the K reading is approximately 2.00 D. However, for the normal cornea (Gullstrand ratio, 0.83), the difference is not nil. This is because the conventional K reading carries an inborn overestimation of the corneal power of approximately 1.00 D. The effect of the two sources of error on IOL power prediction with the SRK/T formula is shown in Figure 5. The K reading error and the ELP error are the same magnitude, and both tend to give a hyperopic error. The total MAY 2012 CATARACT & REFRACTIVE SURGERY TODAY EUROPE 1
2 Figure 1. The Fyodorov concept predicts the IOL position as a function of the corneal height (H), which is calculated from the corneal curvature and diameter. This model is used by the SRK/T formula and the Holladay formula (surgeon s factor [SF] is calculated as an addition to H). Figure 2. Distribution of the Gullstrand ratio in normal and post-lasik populations, as measured by Pentacam. Figure 3. Calculated change of the Gullstrand ratio as a function of the amount of excimer laser myopic ablation on a standard cornea. This figure also includes a regression equation stating the average change per diopter ablation. prediction error is about one-third the amount of the excimer laser ablation if not corrected for. MY PREFERRED METHOD If available, pre-lasik K readings and amount of laser correction should be recorded. The historic method is not regarded as reliable, and therefore we use these data only to check whether our measurements are consistent. As with any other case, the patient should have optical biometry; I prefer the Lenstar LS900 biometer because this instrument measures all intraocular distances (corneal thickness, ACD, lens thickness, and AL) with the accuracy of laser biometry. Additionally, the pupil diameter is also measured. Next, the patient is examined with the Pentacam to determine the anterior and posterior curvatures of the Figure 4. The difference between conventional K reading of the anterior surface and the true corneal power as a function of the Gullstrand ratio. cornea. I like to inspect the readings of the central cornea to check what the effective central reading might be. Useful tools of the Pentacam are its power distribution (Figure 6) and Fourier transformation (Figure 7) functions. These tools allow the surgeon to extract the effective radius in the pupillary area of the cornea. COMMENT Difficulties with reading the effective central part of the cornea add error to any formula. Keratometers usually measure the cornea in a noncentral ring of about 3 mm (about 2.5 mm with the IOLMaster). This is not adequate for a cornea with central flattening, and, in fact, all keratometers and topographers are blind to the central, most significant area of the cornea. Again, the potential error on the IOL power calculation is hyperopic. When information on the effective central anterior curvature of the cornea and the posterior curvature 2 CATARACT & REFRACTIVE SURGERY TODAY EUROPE MAY 2012
3 Figure 5. The prediction error with the SRK/T formula divided into two sources of error: K reading error and ELP error (postoperative ACD) as a function of the amount of laser ablation. Figure 6. Power distribution tool of the Pentacam. Figure 7. Fourier transformation of the central area, showing the spherical component. Figure 8. IOL power prediction error in 24 post-lasik cases plotted against the Gullstrand ratio. are available, we enter these values directly in the PhacoOptics software (PhacoOptics.com) using the Olsen formula for IOL power calculation. 2 The advantage of the Olsen formula is that equivalent K readings are not needed, as the program accepts direct input of front and back corneal curvature. Moreover, the Olsen formula uses an improved algorithm for the prediction of the IOL position, making it possible to base the ELP on the anterior segment anatomy only (ie, preoperative ACD and lens thickness) and avoiding troublesome K reading dependence (eyetube.net/?v=fuhal). In 24 eyes of 19 post-lasik patients for which the Olsen formula was used to calculate IOL power, we found a mean refractive prediction error of 0.41 ±0.68 D (range, to 1.63 D; Figure 8). There was no correlation with the Gullstrand ratio. The one patient with the highest error (1.63 D) was later reexamined and found to have a central cornea that was flatter than was measured at the preoperative visit, possibly caused by wearing a contact lens a few days before. The overall prediction accuracy is not as accurate as in normal eyes (and will never be), but we think the results are encouraging for our approach to be a feasible one. NEW DEVELOPMENTS: RAY TRACING As described above, much of the inaccuracy of IOL power calculations in post-lasik eyes is due to the problem of getting reliable information on the effective refractive power of the cornea. To this end, various models are often used to fit the corneal measurement to certain well-defined shapes, such as ellipsoids, MAY 2012 CATARACT & REFRACTIVE SURGERY TODAY EUROPE 3
4 Figure 9. Pentacam data of front and back surface of the cornea transformed into a polygonal shape and imported by the Zemax software. The individual measurements can be found as points in a meshwork of miniature triangles, suitable for exact ray tracing. Ray tracing is performed directly on the raw physical shape without further model fitting. Zernike polynomials, and Fourier transformations. In physical optics, ray tracing is widely used and recognized as the most effective tool in optical design. The eye is an optical device, so why isn t ray tracing the method of choice in our hands? The answer, perhaps, is because this technology is still evolving. We have recently begun a study to import the Pentacam raw height data into the Zemax software (Radiant Zemax, LLC) for optical engineering. 3 To import the data, we had to transform the matrix array of individual measurement points into a polygonal WATCH IT NOW ON EYETUBE.NET Using your smartphone, photograph the QR codes to watch the videos on Eyetube.net. If you do not have a QR reader on your phone, you can download one at eyetube.net/?v=fuhal Figure 10. The optical system of a pseudophakic eye imported into Zemax software, in this case to solve for the optimal optical properties of the IOL giving the best image at the retinal plane. Insert shows the simulated quality of a Snellen letter projected on the retina. shape that could then be imported by Zemax. When the data are successfully transformed, it is possible to construct the cornea as a meshwork of miniature triangles, suitable for exact ray tracing (Figure 9). The fascinating thing about Zemax and other ray tracing software programs is that it is possible to compose and analyze the entire optical system and ask for optimal performance of any element. For example, how should the IOL be designed to fit the optical properties of the cornea (Figure 10)? For the post-lasik cornea, it might be possible to solve for the higher-order aberrations of the selected IOL needed to correct for the HOA of the cornea. We expect this technology to be further elaborated in the future. n Thomas Olsen, MD, PhD, is a Professor of Ophthalmology at the University Eye Clinic, Aarhus Hospital, in Denmark. Dr. Olsen states that he is a shareholder of IOL Innovations, manufacturer of the PhacoOptics program. He may be reached at tel: ; fax: ; [email protected]. 1. Olsen T. Calculation of intraocular lens power: a review. Acta Ophthalmol Scand. 2007;85(5): Olsen T. Prediction of the effective postoperative (intraocular lens) anterior chamber depth. J Cataract Refract Surg. 2006;32(3): Olsen T, Funding M. Ray tracing analysis of the IOL power in situ. J Cataract Refract Surg. 2012;38: CATARACT & REFRACTIVE SURGERY TODAY EUROPE MAY 2012
5 THE BESSt AND BMR-BHR FORMULAS These formulas are useful for eyes that have previously undergone myopic or hyperopic laser treatments. By Edmondo Borasio, MD, MedCBQ Ophth, FEBO Using standard keratometry and raw data taken from corneal topography to calculate refractive corneal power in postrefractive surgery eyes can result in an inaccurate representation of the true corneal power. In these cases, instead of using a pseudophakic IOL power calculation that incorporates preoperative data, which can result in refractive surprises, I prefer to use direct corneal measurements. I use two approaches to calculate IOL power following laser refractive surgery, the first of which, the Borasio Edmondo Smith and Stevens formulas (BESSt and BESSt 2), is based on direct anterior and posterior corneal surface measurements and requires the Pentacam (Oculus Optikgeräte GmbH). 1 The second approach, the more recently developed Borasio Myopic Regression and Borasio Hyperopic Regression (BMR-BHR) formula, requires direct measurements from the IOLMaster (Carl Zeiss Meditec). These formulas can be used for eyes that have previously undergone myopic or hyperopic excimer laser treatments, even if there is a lack of prerefractive surgery information. BESSt AND BESST 2 Based on direct anterior and posterior corneal curvature and corneal thickness measurements using the Pentacam and a modified Gaussian optics formula, the BESSt algorithm estimates corneal power in eyes after laser refractive surgery for myopia or hyperopia. It is not possible to use values obtained from the Gaussian optics formula in most current IOL power formulas because they are calibrated using a standard keratometric index of , which does not take true posterior corneal curvature into account. This can therefore yield inaccurate results, especially in postrefractive surgery eyes where the relationship between the anterior and posterior corneal radii is no longer constant. BESSt starts from the true net corneal power as calculated with the Gaussian optics formula, but then it makes crucial adjustments based on the actual measured postoperative corneal radii and the altered anterior/posterior radius relationship. We have found that the BESSt 2, a second iteration of the formula, results in greater prediction accuracy and less risk of refractive surprise after hyperopic treatments (unpublished data). BESSt 2 incorporates the following improvements compared with its predecessor: (1) automatic prediction of the preoperative anterior corneal radius from postoperative posterior corneal radius measurement, thus allowing automatic application of Aramberri s double-k adjustment for a more accurate prediction of the estimated IOL position, (2) two separate algorithms based on the results of regression analyses, one for myopic and one for hyperopic treatments, (3) automatic application of the BESSt 2-derived corneal power to a modified third-generation formula for the purpose of IOL power calculation, and (4) an error-limitation algorithm to prevent serious errors in eyes with extreme axial lengths. BMR-BHR The latest formulas I have developed for postrefractive surgery eyes, the BMR and BHR, require the use of the IOLMaster to measure K values and axial length. 2-4 From the measured postrefractive surgery K value, a new corneal power value is obtained by using one of these regression formulas. The resulting corneal power values are then automatically entered into the SRK/T formula, yielding a suggested IOL power. The BMR-BHR formulas are based on linear, logarithmic, and polynomial regression analyses and give similar results in most cases, with no greater than 0.25 D difference between the analyses with the exception of eyes with very steep or very flat corneas, where differences can be more substantial. Further studies are needed to determine which formula is the most accurate, but I tend to use linear regression. Polynomial regression has a smaller error in the majority of cases, but it can also have more serious outliers than linear regression; logarithmic regression lies in between the other two. It is best to use polynomial regression only when the suggested IOL power value is neither too low nor too high. BMR-BHR is currently available only as part of Eye Pro 2012 for the iphone/ipad. A desktop version will soon be available as an upgrade to the BESSt 2 IOL Power Calculator. CONSIDERATIONS AND RESULTS The same considerations apply to the BESSt, BESSt 2, and BMR-BHR formulas; they should not be used in the presence of significant corneal haze or scarring or after incisional refractive surgery such as radial keratotomy. Additionally, these formulas should be used with caution in eyes that have undergone astigmatic keratotomy; in eyes that have previously undergone myopic or hyperopic treatments for severe refractive errors; or in eyes that were operated on a long time ago using small optical zones. Other considerations include the following: The BMR-BHR requires K values specifically mea- MAY 2012 CATARACT & REFRACTIVE SURGERY TODAY EUROPE 5
6 Figure 1. Screenshots taken from Eye Pro 2012: (From left to right) BMR-BHR for IOLMaster, mobile version of BESSt 2 myopia, double-angle polar plot showing the average surgically induced astigmatism in a group of eyes, standard biometry on the go, and IOL power matrix. sured by the IOLMaster; I recommended comparing BESSt 2 with BMR- BHR. If the BESSt 2 formula suggests a very low (or very high) IOL power, I either use the BMR-BHR formula instead or the average of the two. It is always advisable to compare with other methods before proceeding with surgery. Whenever in the doubt, opt for a stronger IOL to target myopia; Be suspicious of very low or very high IOL powers resulting from BMR-BHR or BESSt in eyes with very steep or very flat corneas. These cases are at the extreme edges of any regression analysis, and the risk of a refractive surprise is high; and The BESSt 2 and the Eye Pro have not been approved by the US Food and Drug Administration (FDA) or received the Conformiteé Europeénne (CE) Mark. I recently conducted a study in 62 eyes, of which 38 received a myopic treatment and 24 a hyperopic, to compare the accuracy of the BESSt, BESSt 2, and BMR- BHR formulas. In the myopic group, BESSt and BESSt 2 performed similarly (mean error, ±0.78 D and ±0.81 D, respectively; P>.05), but in the hyperopic group BESSt 2 performed statistically significantly better (-1.10 ±0.90 D and 0.02 ±1.00 D, respectively; P<.05). The proportion of eyes within ±0.50 D of the intended target changed negligibly (from 37% to 38%) in the myopic group but improved significantly (from 13% to 38%) in the hyperopic group. The proportion of eyes within ±1.00 D of the target changed from 73% to 76% in the myopic group and from 38% to 75% in the hyperopic group. Comparing the results with BESSt 2 to those with BMR and BHR, in the myopic group, the mean error was ±0.81 D with BESSt 2 and 0.00 ±0.75 D with BMR (P>.05). In the hyperopic group, the mean error was 0.02 ±1.00 D for BESSt 2 and 0.01 ±0.75 D for BHR (P>.05). Although these differences were not statistically significant, 31% more eyes were ±0.50 D or less from the target refraction with BMR compared with BESSt 1 and 30% more compared with BESSt 2. Similarly, with BHR 50% more eyes were ±0.50 D or less from the target compared with BESSt 1 and 13% more compared with BESSt 2. We believe this represents an improvement. PC VERSION FOR THE PENTACAM The BESSt 2 IOL Power Calculator (EB Eye Ltd, UK; besstformula.com) is available as an optional software add-on for the Pentacam. The main advantage of this calculator is that it can be installed on the same computer as the Pentacam. Therefore, calculations can be done directly from the Pentacam program by clicking on the BESSt 2 button, which will export all the required data (anterior and posterior corneal curvature and central pachymetry) to the program for the calculations. The program also keeps a database of calculations for future reference and for recalculation. A standalone version for research purposes is also available and can be used on a laptop not physically connected to the Pentacam hardware. Another feature of the BESSt 2 IOL Power Calculator for PC is real-time IOL power plotting to show the behavior of different biometry formulas when parameters are modified for any given axial length. This allows immediate identification of potential biometry artifacts that affect any given formula. Examples include the SRK/T negative square root and cusp phenomena that occur for certain combinations of axial length and K values (most frequently for steep corneas). When not identified, these artifacts can lead to inaccurate IOL power calculations. 6 CATARACT & REFRACTIVE SURGERY TODAY EUROPE MAY 2012
7 WATCH IT NOW ON EYETUBE.NET Using your smartphone, photograph the QR codes to watch the videos on Eyetube.net. If you do not have a QR reader on your phone, you can download one at Direct Link eyetube.net/?v=fireb The BESSt IOL Power Calculator also allows the practitioner to compare the results with the historical method with or without the double-k adjustment, and using refractions at the spectacle or at the corneal plane for eyes for which prerefractive surgery information is available. A video presentation on BESSt and BMR-BHR is available at eyetube.net/?v=fireb. MOBILE VERSION AND APP A mobile version of the program, Eye Pro 2012 (Figure 1), is more suited for quick calculations. It includes not only BESSt 2 and BMR-BHR algorithms but also many other functions such as standard biometry and surgically induced astigmatism calculations. Our smartphone application (app) is a suite of ophthalmic calculators that includes the following advanced functions: Standard biometry (SRK/T, Hoffer Q formulas); BESSt 1 combined with third-generation formulas with double-k adjustment for biometry after refractive surgery; Toric IOL calculator that also accounts for surgically induced astigmatism (SIA); SIA calculator for K values or refractions; SIA plotter for group analysis showing both the vector and the arithmetic means; Visual acuity converter between Snellen/decimal/ logmar notation; Refraction converter between corneal/spectacle plane; Astigmatism converter between cartesian/polar notation; and Optical formulas including thin lens equation, Gaussian optics formula, and calculations using customized keratometric refractive indexes. Eye Pro 2012 is available for the iphone and ioscompatible devices and can be downloaded directly from the Apple store. A free trial version, Eye Pro Lite, is available at the Apple store and shows all the functions available in the 2012 version. n Edmondo Borasio, MD, MedCBQ Ophth, FEBO, is a Corneal Specialist and Consultant Ophthalmic Surgeon at Moorfields Eye Hospital Dubai. Dr. Borasio states that he is owner of and shareholder in EB Eye, Ltd. He may be reached at [email protected]. 1. Borasio E, Stevens J, Smith GT. Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula. J Cataract Refract Surg. 2006;32(12): Borasio E. BESSt and beyond: The Borasio regression. Paper presented at the: 6th IOL Power Club Meeting; September 2010; Venice, Italy. 3. Borasio E. IOL power calculation accuracy in post-myopic and hyperopic ablations using the Borasio Regression formula. Paper presented at: the American Society of Cataract and Refractive Surgery Annual Meeting; March 2011; San Diego. 4. Borasio E. Post-LASIK IOL power calculation with Pentacam without pre-refractive surgery information. Paper presented at: the World Ophthalmology Congress; June 2010; Berlin. This article is reprinted with permission from Cataract & Refractive Surgery Today Europe. MAY 2012 CATARACT & REFRACTIVE SURGERY TODAY EUROPE 7
8
IOL Power Calculations for Postrefractive Surgery Eyes
eyetube.net The Creator s Forum: IOL Power Calculations for Postrefractive Surgery Eyes The minds behind today s commonly used formulas provide overviews and pearls for use. By Wolfgang Haigis, Ms, PhD;
IOL Power Calculation After Myopic LASIK. Hany Helaly, Lecturer of Ophthalmology, Faculty of Medicine, Alexandria University.
IOL Power Calculation After Myopic LASIK Hany Helaly, Lecturer of Ophthalmology, Faculty of Medicine, Alexandria University. SUPERVISORS Prof. Dr. Mohammad El-Hifnawy Professor of Ophthalmology Faculty
Insert to. January 2011. Comfort and confidence for all IOL calculations
Insert to January 2011 Comfort and confidence for all IOL calculations Advanced Optical Biometry and Keratometry with LENSTAR LS 900 CONTENTS Lenstar and Ray-Tracing Calculations...3 By Jaime Aramberri,
IOL Calculation After LASIK. Chapter (3)
the cornea (P) may be considered as the sum of the power of the anterior (Pa) and posterior (Pp) corneal surfaces, as shown in the formula: P = Pa + Pp = (n2 n1)/r1 + (n3 n2)/r2, where n1 is the refractive
No-history method of intraocular lens power calculation for cataract surgery after myopic laser in situ keratomileusis
J CATARACT REFRACT SURG - VOL 33, JANUARY 2007 No-history method of intraocular lens power calculation for cataract surgery after myopic laser in situ keratomileusis H. John Shammas, MD, Maya C. Shammas,
Total Corneal Power Estimation: Ray Tracing Method versus Gaussian Optics Formula PATIENTS AND METHODS
Cornea Total Corneal Power Estimation: Ray Tracing Method versus Gaussian Optics Formula Li Wang, 1 Ashraf M. Mahmoud, 2 Betty Lise Anderson, 3 Douglas D. Koch, 1 and Cynthia J. Roberts 2 PURPOSE. To evaluate
Simple regression formula for intraocular lens power adjustment in eyes requiring cataract surgery after excimer laser photoablation
J CATARACT REFRACT SURG - VOL 32, MARCH 26 Simple regression formula for intraocular lens power adjustment in eyes requiring cataract surgery after excimer laser photoablation Samuel Masket, MD, Seth Everett
BESSt 2.0 IOL Power Calculator - REFERENCE GUIDE
BESSt 2.0 IOL Power Calculator - REFERENCE GUIDE Introduction BESSt 2.0 IOL Power Calculator was designed to allow more accurate corneal and IOL power estimation in eyes needing either cataract or clear
Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula
J CATARACT REFRACT SURG - VOL 32, DECEMBER 2006 ARTICLES Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula Edmondo Borasio, MedCBQ Ophth,
ALL-IN-ONE Optical Biometry, Dual Scheimpflug Tomography and Placido Topography
ALL-IN-ONE Optical Biometry, Dual Scheimpflug Tomography and Placido Topography GALILEI G6 Clinical Applications High confidence premium IOL selection The GALILEI G6 offers a link to the ray-tracing software
THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening
THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening GALILEI G4 Clinical Applications Corneal Implant Planning The comes with a licensable corneal inlay software
Update on Post- Refractive Surgery IOL Calculations
Update on Post- Refractive Surgery IOL Calculations Hawaiian Eye 2014 Kauai Rhonda G Waldron MMSc, COMT, CRA, ROUB, RDMS Diagnostic Echographer, Senior Associate in Ophthalmology Emory Eye Center Atlanta,GA
Supplement to October 2014. Master Your Toric Planning and Improve Refractive Outcomes With the LENSTAR LS 900. Sponsored by
Supplement to October 2014 Master Your Toric Planning and Improve Refractive Outcomes With the LENSTAR LS 900 Sponsored by Contents Lenstar and the T-Cone Toric Platform... xx Offering sophisticated planning
Insert to October 2013 THE COMPLETE PICTURE. Experiences with the ALADDIN system. Sponsored by Topcon
Insert to October 2013 THE COMPLETE PICTURE Experiences with the ALADDIN system Sponsored by Topcon THE COMPLETE PICTURE Advantages of The Aladdin How this all-in-one optical biometer edged out the IOLMaster
Intraocular lens power calculation after corneal refractive surgery Sachin D. Kalyani, Alisa Kim and John G. Ladas
Intraocular lens power calculation after corneal refractive surgery Sachin D. Kalyani, Alisa Kim and John G. Ladas Department of Ophthalmology, Wilmer Ophthalmologic Institute, Johns Hopkins School of
Comparison of Corneal Power and Intraocular Lens Power Calculation Methods after LASIK for Myopia. Abstract
Comparison of Corneal Power and Intraocular Lens Power Calculation Methods after LASIK for Myopia Seyed Mohammad Reza Taheri, MD 1 Azita Kheiltash, MD, MPH 2 Hassan Hashemi, MD 1,3 Abstract Purpose: To
Technicians & Nurses Program
ASCRS ASOA Symposium & Congress Technicians & Nurses Program April 17-21, 2015 San Diego, California Update on Post-Refractive Surgery IOL Calculations ASCRS Technicians and Nurses Program April 18 th,
Corneal Refractive Power Estimation and Intraocular Lens Calculation after Hyperopic LASIK
Corneal Refractive Power Estimation and Intraocular Lens Calculation after Hyperopic LASIK Shady T. Awwad, MD, 1,2 Patrick S. Kelley, MD, 1 R. Wayne Bowman, MD, 1 H. Dwight Cavanagh, MD, PhD, 1 James P.
OCT-based IOL power calculation for eyes with previous myopic and hyperopic laser vision correction
American Academy of Ophthalmology Annual Meeting Orlando, Florida, 21-25 October 2011 OCT-based IOL power calculation for eyes with previous myopic and hyperopic laser vision correction Weeks Professor
Corneal Power Measurements Using Scheimpflug Imaging in Eyes With Prior Corneal Refractive Surgery
Corneal Power Measurements Using Scheimpflug Imaging in Eyes With Prior Corneal Refractive Surgery Jack T. Holladay, MD, MSEE, FACS; Warren E. Hill, MD, FACS; Andreas Steinmueller, MSc ABSTRACT PURPOSE:
articles Intraocular lens power calculation after corneal refractive surgery: Double-K method Jaime Aramberri, MD
articles Intraocular lens power calculation after corneal refractive surgery: Double-K method Jaime Aramberri, MD Purpose: To determine the accuracy of a method of calculating intraocular lens (IOL) power
Incision along Steep Axis
Toric IOL An option or a must? ~ 15% cataract surgical patients >1.5 D Options: spectacles, CLs, Incision along steep axis, LRI, AK, toric IOL, Excimer Laser or a combination Walter J. Stark, MD Professor
COMPARISON OF INTRAOCULAR LENS POWER CALCULATION METHODS IN EYES THAT HAVE UNDERGONE LASER-ASSISTED IN-SITU KERATOMILEUSIS
COMPARISON OF INTRAOCULAR LENS POWER CALCULATION METHODS IN EYES THAT HAVE UNDERGONE LASER-ASSISTED IN-SITU KERATOMILEUSIS BY Li Wang MD PhD, Marc A. Booth MD, AND Douglas D. Koch MD* ABSTRACT Purpose:
Premium Lenses in Problematic Patients
Premium Lenses in Problematic Patients How to be successful with presbyopic lenses in eyes that have already had LASIK surgery. Walter Bethke, Managing Editor If implanting a monofocal intraocular lens
Keratoconus Detection Using Corneal Topography
Keratoconus Detection Using Corneal Topography Jack T. Holladay, MD, MSEE, FACS ABSTRACT PURPOSE: To review the topographic patterns associated with keratoconus suspects and provide criteria for keratoconus
INTRODUCTION. Trans Am Ophthalmol Soc 2006;104:402-413
ORBSCAN II ASSISTED INTRAOCULAR LENS POWER CALCULATION FOR CATARACT SURGERY FOLLOWING MYOPIC LASER IN SITU KERATOMILEUSIS (AN AMERICAN OPHTHALMOLOGICAL SOCIETY THESIS) BY Henry Gelender MD ABSTRACT Purpose:
How do we use the Galilei for cataract and refractive surgery?
How do we use the Galilei for cataract and refractive surgery? Douglas D. Koch, MD Mariko Shirayama, MD* Li Wang, MD, PhD* Mitchell P. Weikert, MD Cullen Eye Institute Baylor College of Medicine Houston,
IOLMaster 500. Excellence in Biometry. Precision. Simplicity. Outcomes.
IOLMaster 500 Excellence in Biometry. Precision. Simplicity. Outcomes. 2 IOLMaster 500 The gold standard in biometry is evolving to meet today s challenges Mastery is achieved through continuous practice
Refractive Surgery. Evolution of Refractive Error Correction
Refractive Surgery Techniques that correct for refractive error in the eye have undergone dramatic evolution. The cornea is the easiest place to place a correction, so most techniques have focused on modifying
final corrected draft
Archived at the Flinders Academic Commons http://dspace.flinders.edu.au/dspace/ This is the author s final corrected draft of this article. It has undergone peer review. Citation for the publisher s version:
Wavefront technology has been used in our
Wavefront Customized Ablations With the WASCA Asclepion Workstation Sophia I. Panagopoulou, BSc; Ioannis G. Pallikaris, MD ABSTRACT PURPOSE: WASCA (Wavefront Aberration Supported Cornea Ablation) is a
Premium IOL Implantation Calculations in Post-LASIK Cataract Eyes Using ASCRS IOL Calculator
Premium IOL Implantation Calculations in Post-LASIK Cataract Eyes Using ASCRS IOL Calculator Sahiba K Chailertborisuth, Saneha K. C. Borisuth, Navaneet S.C. Borisuth, MD, PhD Virdi Eye Clinic & Laser Vision
Cataract Testing. What a Patient undergoes prior to surgery
Cataract Testing What a Patient undergoes prior to surgery FINANCIAL DISCLOSURE I have no financial interest or relationships to disclose What do most Technicians find to be the most mundane yet very important
IBRA Professional. Leading Technology for Refractive Outcome Analysis. Brochure 2015
IBRA Professional Leading Technology for Refractive Outcome Analysis Brochure 2015 Introduction IBRA is the leading all-in-one system for refractive laser and lens surgery outcomes, allowing eye surgeons
Customized corneal ablation and super vision. Customized Corneal Ablation and Super Vision
Customized Corneal Ablation and Super Vision Scott M. MacRae, MD; James Schwiegerling, PhD; Robert Snyder, MD, PhD ABSTRACT PURPOSE: To review the early development of new technologies that are becoming
The Pentacam: Precision, Confidence, Results, and Accurate Ks!
The Pentacam: Precision, Confidence, Results, and Accurate Ks! Produced under an unrestricted educational grant from Oculus, Inc. This monograph is based on an informational symposium presented at the
Physics 1230: Light and Color
Physics 1230: Light and Color The Eye: Vision variants and Correction http://www.colorado.edu/physics/phys1230 What does 20/20 vision mean? Visual acuity is usually measured with a Snellen chart Snellen
Rediscover quality of life thanks to vision correction with technology from Carl Zeiss. Patient Information
Rediscover quality of life thanks to vision correction with technology from Carl Zeiss Patient Information 5 2 It was really w Vision defects: Light that goes astray For clear vision the eyes, cornea and
Posterior Corneal Astigmatism: Is It Important? MP Weikert, MD Baylor College of Medicine October 23, 2011
: Is It Important? MP Weikert, MD Baylor College of Medicine October 23, 2011 Corneal Imaging What major challenge do we face when imaging the cornea? Measuring the curvature & refractive power of the
Cataract Surgery in Small Eyes Richard S. Hoffman, MD Clinical Associate Professor of Ophthalmology Oregon Health & Science University No Financial Interests Anatomic Classification Short AC depth with
ADVANCED IOL POWER CALCULATIONS. Jack T. Holladay, MD, MSEE, FACS
Jack T. Holladay, M.D., M.S.E.E., F.A.C.S. ADVANCED IOL POWER CALCULATIONS Jack T. Holladay, MD, MSEE, FACS I. Formulas and Measurements A. Variables Used to Predict ACD 1. Binkhorst 2-1981 - AL 2. Holladay
Robert A. Latkany, MD, Amit R. Chokshi, MD, Mark G. Speaker, MD, PhD, Jodi Abramson, MD, Barrie D. Soloway, MD, Guopei Yu, MD, MPH
Intraocular lens calculations after refractive surgery Robert A. Latkany, MD, Amit R. Chokshi, MD, Mark G. Speaker, MD, PhD, Jodi Abramson, MD, Barrie D. Soloway, MD, Guopei Yu, MD, MPH Purpose: To evaluate
Curtin G. Kelley, M.D. Director of Vision Correction Surgery Arena Eye Surgeons Associate Clinical Professor of Ophthalmology The Ohio State
Curtin G. Kelley, M.D. Director of Vision Correction Surgery Arena Eye Surgeons Associate Clinical Professor of Ophthalmology The Ohio State University Columbus, Ohio Refractive Errors Myopia (nearsightedness)
Optimizing refractive outcomes
APACRS The news magazine of the Asia-Pacific Association of Cataract & Refractive Surgeons Supplement to EyeWorld Asia-Pacific Winter 2014 Asia-Pacific Surgical management of astigmatism Sponsored by Abbott
EUROPEAN JOURNAL OF PHARMACEUTICAL AND MEDICAL RESEARCH www.ejpmr.com
ejpmr, 2015,2(3), 436-440 EUROPEAN JOURNAL OF PHARMACEUTICAL AND MEDICAL RESEARCH www.ejpmr.com Tumram et al. SJIF Impact Factor 2.026 Research Article ISSN 3294-3211 EJPMR CLINICAL OUTCOME OF TORIC IOL
KERATOCONUS IS A BILATERAL, ASYMMETRIC, CHRONIC,
Comparison of and Intacs for Keratoconus and Post-LASIK Ectasia MUNISH SHARMA, MD, AND BRIAN S. BOXER WACHLER, MD PURPOSE: To evaluate the efficacy of single-segment Intacs and compare with double-segment
Staying on Target With Better Biometry
Insert to Sponsored by an educational grant from Haag-Streit USA January 2010 Staying on Target With Better Biometry A roundtable discussion about the new LENSTAR LS900, the first biometer of the entire
Insert to October 2014. Sponsored by OCULUS Optikgeräte GmbH EXPERT STRATEGIES FOR YOUR DAILY PRACTICE. Pentacam Take a closer look.
Insert to October 2014 Sponsored by OCULUS Optikgeräte GmbH EXPERT STRATEGIES FOR YOUR DAILY PRACTICE Pentacam Take a closer look. Contents Improving Quality of Vision After Cataract Surgery... 3 BY H.
Excimer Laser Refractive Surgery
Excimer Laser Refractive Surgery In the field of ophthalmology has achieved great technological advances and, undoubtedly, the most representative have focused on refractive surgery, which aims to eliminate
ADVANCED IOL POWER CALCULATIONS. Jack T. Holladay, MD, MSEE, FACS
Jack T. Holladay, M.D., M.S.E.E., F.A.C.S. ADVANCED IOL POWER CALCULATIONS Jack T. Holladay, MD, MSEE, FACS I. Formulas and Measurements A. Variables Used to Predict ACD 1. Binkhorst 2-1981 - AL 2. Holladay
Customized corneal ablation can be designed. Slit Skiascopic-guided Ablation Using the Nidek Laser. Scott MacRae, MD; Masanao Fujieda
Slit Skiascopic-guided Ablation Using the Nidek Laser Scott MacRae, MD; Masanao Fujieda ABSTRACT PURPOSE: To present the approach of using a scanning slit refractometer (the ARK 10000) in conjunction with
Making the Most of High-tech Biometry
4/2/2014 Making the Most of High-tech Biometry Today s advanced technology calls for a well-informed user in order to optimize results. Here s help. By Christopher Kent Senior Editor As cataract surgery
Looking for Keratoconus
07.31.06 Screening for LASIK: Tips and Techniques Surgeons share helpful strategies for identifying which patients are good candidates and which could be trouble. Christopher Kent, Senior Editor Screening
Surgical Advances in Keratoconus. Keratoconus. Innovations in Ophthalmology. New Surgical Advances. Diagnosis of Keratoconus. Scheimpflug imaging
Surgical Advances in Keratoconus Keratoconus Ectatic disorder 1 in 1,000 individuals Starts in adolescence & early adulthood Uncertain cause 20% require corneal transplant Innovations in Ophthalmology
Calculation of intraocular lens (IOL) power for
A New Method of Calculating Intraocular Lens Power After Photorefractive Keratectomy Nicola Rosa, MD; Luigi Capasso, MD; Antonio Romano, MD ABSTRACT PURPOSE: To find a method of calculating intraocular
OCULUS PENTACAM BASIC CLASSIC HR
OCULUS PENTACAM BASIC CLASSIC We focus on progress Many Patients have Apprehensions before an Examination. > The eye is an extremely sensitive area Loss or impairment of sight always produces anxiety.
Cataract Surgery after Myopic Refractive Procedures. Ray Guard Eye Center Huang Wei-Jen, MD
Cataract Surgery after Myopic Refractive Procedures Ray Guard Eye Center Huang Wei-Jen, MD Financial Disclosures : * No financial interest on products mentioned Cataract Surgery after Myopic Refractive
The Calhoun adjustable IOL breaks new ground
Page 1 of 5 Article Date: 3/1/2014 Focus on Cornea The Calhoun adjustable IOL breaks new ground Chemical technology allows the lens reshape itself to produce precise outcomes after implantation. BY JERRY
Overview of Refractive Surgery
Overview of Refractive Surgery Michael N. Wiggins, MD Assistant Professor, College of Health Related Professions and College of Medicine, Department of Ophthalmology Jones Eye Institute University of Arkansas
Seeing Better: Optimizing Surgically Induced Astigmatism Correction Factors for Cataract Surgery * Erin Milne and Nelson Winkler Erin Milne is a Senior in Genomics and Molecular Genetics. After graduation
Dr. Booth received his medical degree from the University of California: San Diego and his bachelor of science from Stanford University.
We've developed this handbook to help our patients become better informed about the entire process of laser vision correction. We hope you find it helpful and informative. Dr. Booth received his medical
Irregular astigmatism:
Irregular astigmatism: definition, classification, topographic and clinical presentation Ming X. Wang, MD, PhD Clinical Associate Professor of Ophthalmology of University of Tennessee Director, Wang Vision
Laser Refractive Cataract Surgery with the LenSx Laser
Laser Refractive Cataract Surgery with the LenSx Laser a Novartis company LenSx Laser 2 3 An Evolving Definition of Cataract Average Age of US Cataract Patient is Projected to Decline Today: earlier diagnosis
ReLEx smile Minimally invasive vision correction Information for patients
ReLEx smile Minimally invasive vision correction Information for patients Seeing is living Our eyes are our most important sensory organ. The human brain obtains over 80 % of its information via the sense
Cornea and Refractive Surgery Update
Cornea and Refractive Surgery Update Fall 2015 Optometric Education Dinner Sebastian Lesniak MD Matossian Eye Associates Disclosures: None Bio: Anterior Segment and Cornea Surgery Fellowship Wills Eye
The Evolution of the Optical Zone in Corneal Refractive Surgery. Bruce Drum, Ph.D.
The Evolution of the Optical Zone in Corneal Refractive Surgery. Bruce Drum, Ph.D. FDA, Division of Ophthalmic and ENT Devices, Rockville, MD Disclaimer This presentation represents the professional opinion
Phacoemulsification: Considerations for Astigmatism Management Jason P. Brinton, MD and Thomas A. Oetting, MS, MD June 10, 2011
Phacoemulsification: Considerations for Astigmatism Management Jason P. Brinton, MD and Thomas A. Oetting, MS, MD June 10, 2011 Introduction Patient expectations for cataract surgery have increased significantly
Intraocular lens (IOL) power calculations for cataract
Intraocular lens power calculation after incisional and thermal keratorefractive surgery Mark Packer, MD, Laurie K. Brown, COMT, COE, Richard S. Hoffman, MD, I. Howard Fine, MD Purpose: To evaluate the
Refractive Errors. Refractive Surgery. Eye Care In Modern Life. Structure of the Eye. Structure of the Eye. Structure of the Eye. Structure of the Eye
Structure of the Eye Eye Care In Modern Life Dr. Dorothy Fan Department of Ophthalmology & Visual Sciences September 2007 Information age > 90% of sensory input Blindness is one of the most fearful disabilities
Eye Care In Modern Life
Eye Care In Modern Life Dr. Dorothy Fan Department of Ophthalmology & Visual Sciences November 2009 [email protected] Structure of the Eye Information age > 90% of sensory input Blindness is one of
Refractive Surgery. Common Refractive Errors
Refractive Surgery Over the last 25 years developments in medical technology and Refractive Surgery allow almost all need for glasses and contact lenses to be eliminated. Currently there are a number of
INTRACOR. An excerpt from the presentations by Dr Luis Ruiz and Dr Mike Holzer and the Round Table discussion moderated by Dr Wing-Kwong Chan in the
INTRACOR An excerpt from the presentations by Dr Luis Ruiz and Dr Mike Holzer and the Round Table discussion moderated by Dr Wing-Kwong Chan in the 1 Dr Luis Ruiz Presbyopia treatment with INTRACOR Luis
OCULUS Pentacam Pentacam HR
OCULUS Pentacam Pentacam HR The Gold Standard in Anterior Segment Tomography We focus on progress Providing the best care to your patients > The eye is extremely sensitive. Loss or impairment of sight
Role of Galilei in IOL power calculations in post-lasik/prk and post-rk eyes
Role of Galilei in IOL power calculations in post-lasik/prk and post-rk eyes Li Wang, M.D., Ph.D, Mariko Shirayama, M.D. Christopher M. Pruet, Mitchell M Weikert, M.D. Douglas D. Koch, M.D. Cullen Eye
The Pentacam: Offering a Clearer View
Supplement to Sponsored by an educational grant from Oculus, Inc. February 2008 The Pentacam: Offering a Clearer View Densitometry software for cataracts Topography for premium-channel cataract surgery
Standardized Analyses of Correction of Astigmatism With the Visian Toric Phakic Implantable Collamer Lens
Standardized Analyses of Correction of Astigmatism With the Visian Toric Phakic Implantable Collamer Lens Donald R. Sanders, MD, PhD; Edwin J. Sarver, PhD ABSTRACT PURPOSE: To demonstrate the methodology
Informed Consent for Refractive Lens Exchange (Clear Lens Extraction)
Informed Consent for Refractive Lens Exchange (Clear Lens Extraction) This form is designed to ensure that you have all the information you need to make a decision about whether or not you wish to undergo
Informed Consent for Refractive Lens Exchange (Clear Lens Replacement)
Mark Packer, M.D. Informed Consent for Refractive Lens Exchange (Clear Lens Replacement) This surgery involves the removal of the natural lens of my eye, even though it is not a cataract. The natural lens
By Dr Waleed Al-Tuwairqi, MD Dr Omnia Sherif, MD Ophthalmology Consultants, Elite Medical & Surgical Center Riyadh -KSA.
By Dr Waleed Al-Tuwairqi, MD Dr Omnia Sherif, MD Ophthalmology Consultants, Elite Medical & Surgical Center Riyadh -KSA Rome, Italy 2013 بسم الرحمن الرحيم In the name of Allah, Most Gracious, Most Merciful
refractive surgery a closer look
2011-2012 refractive surgery a closer look How the eye works Light rays enter the eye through the clear cornea, pupil and lens. These light rays are focused directly onto the retina, the light-sensitive
Page: 1 of 6. Corneal Topography/Computer-Assisted Corneal Topography/ Photokeratoscopy
Section: Surgery Effective Date: July 15, 2015 Last Review Status/Date: June 2015 Page: 1 of 6 Corneal Topography/ Photokeratoscopy Description Computer-assisted topography/photokeratoscopy provides a
FIRST EXPERIENCE WITH THE ZEISS FEMTOSECOND SYSTEM IN CONJUNC- TION WITH THE MEL 80 IN THE US
FIRST EXPERIENCE WITH THE ZEISS FEMTOSECOND SYSTEM IN CONJUNC- TION WITH THE MEL 80 IN THE US JON DISHLER, MD DENVER, COLORADO, USA INTRODUCTION AND STUDY OBJECTIVES This article summarizes the first US
AcrySof IQ Toric IOL (SN6ATT) Surgeon Keys for Success & Acknowledgement
AcrySof IQ Toric IOL (SN6ATT) Surgeon Keys for Success & Acknowledgement Alcon Laboratories, Inc is pleased to announce the availability of the AcrySof IQ Toric intraocular lens, and delighted that you
SCHWIND CAM Perfect Planning wide range of applications
SCHWIND CAM Perfect Planning wide range of applications ORK-CAM PresbyMAX PALK-CAM PTK-CAM 2 SCHWIND CAM the system solution The latest version of the modular SCHWIND CAM represents an even more efficient
Corneal intrastromal implantation surgery for the treatment of moderate and high myopia
TECHNIQUE Corneal intrastromal implantation surgery for the treatment of moderate and high myopia Albert Daxer, MD, PhD I describe a corneal intrastromal implantation technique that uses a new type of
Vision Glossary of Terms
Vision Glossary of Terms EYE EXAMINATION PROCEDURES Eyeglass Examinations: The standard examination procedure for a patient who wants to wear eyeglasses includes at least the following: Case history; reason
Keratorefractive Surgery for Post-Cataract Refractive Surprise. Moataz El Sawy
Keratorefractive Surgery for Post-Cataract Refractive Surprise Moataz El Sawy Departmentof Ophthalmology, Faculty of Medicine,MenoufiyaUniversity, Egypt [email protected] Abstract: Purpose: To evaluate
Validation of a New Scoring System for the Detection of Early Forme of Keratoconus
10.5005/jp-journals-10025-1019 Alain Saad, Damien Gatinel ORIGINAL ARTICLE Validation of a New Scoring System for the Detection of Early Forme of Keratoconus Alain Saad, Damien Gatinel ABSTRACT Purpose:
