Agilent 4338B Milliohm Meter



Similar documents
Agilent 4339B/4349B High Resistance Meters

The Next Generation in Automated Oscilloscope Test

Agilent 87421A/87422A Power Supply

Agilent Television Power Consumption Testing. Application Note

Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note

Agilent U2000 Series USB Power Sensors

Agilent 8762/3/4A,B,C Coaxial Switches

Agilent Automotive Power Window Regulator Testing. Application Note

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems

PCI Express 1.0 (2.5 GT/s) Protocol Test

Agilent U2000 Series USB Power Sensors

Agilent E5063A ENA Series Network Analyzer

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Agilent E6832A W-CDMA Calibration Application

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent P940xA/C Solid State PIN Diode Switches

Agilent U2000 Series USB Power Sensors

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

Agilent Mobile WiMAX R&D Test Set Solutions: Software and Technical Support Contract

Agilent N5970A Interactive Functional Test Software: Installation and Getting Started

PXI and AXIe Modular Instrumentation

PXI and AXIe Modular Instrumentation

Agilent E5100A Network Analyzer

1.5 GHz Active Probe TAP1500 Datasheet

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator

TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits

Agilent FieldFox Remote Viewer

Installation Guide E Dielectric Probe Kit 85071E Materials Measurement Software

Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide

Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers

Agilent E4980A Precision LCR Meter 20 Hz to 2 MHz

Multi-Range Programmable DC Power Supplies 9115 Series

U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes

1.44 kw Programmable DC Power Supplies XLN Series

802.11ac Power Measurement and Timing Analysis

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

SWITCH-MODE POWER SUPPLY CONTROLLER PULSE OUTPUT DC OUTPUT GROUND EXTERNAL FUNCTION SIMULATION ZERO CROSSING INPUT CONTROL EXTERNAL FUNCTION

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

Accuracy counts! SENSORS WITH ANALOG OUTPUT

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

Multi-Range Programmable DC Power Supplies 9115 Series

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz

Make Better RMS Measurements with Your DMM

Agilent 4284A/4285A Precision LCR Meter Family

DCS Series 1 kw, 1.2 kw, & 3 kw

Impedance 50 (75 connectors via adapters)

High Power Programmable DC Power Supplies PVS Series

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

TDA4605 CONTROL CIRCUIT FOR SWITCH MODE POWER SUPPLIES USING MOS TRANSISTORS

Agilent 8753ET/8753ES Network Analyzers

Agilent E5063A ENA Series Network Analyzer. 100 khz to 4.5/ 8.5/18 GHz

Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION

Agilent OSS access7 Signaling Meter

Physical Specifications (Custom design available.)

Building Hybrid Test Systems, Part 1

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

Agilent Technologies E8047B Analysis Probe System for the Intel Xeon Processor Family

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet

Keysight N6854A Geolocation System. Configuration Guide

TDA2822 DUAL POWER AMPLIFIER SUPPLY VOLTAGE DOWN TO 3 V LOW CROSSOVER DISTORSION LOW QUIESCENT CURRENT BRIDGE OR STEREO CONFIGURATION

E5061B-3L5 LF-RF Network Analyzer with Option 005 Impedance Analysis Function. Data Sheet

5320A Multifunction Electrical Tester Calibrator. Verify and calibrate electrical test tools with a single instrument

DC Electronic Loads 8500 series

L4940 series VERY LOW DROP 1.5 A REGULATORS

TORKEL 820 Battery Load Unit

Everything you need for protection scheme testing

HCF4056B BCD TO 7 SEGMENT DECODER /DRIVER WITH STROBED LATCH FUNCTION

Think SAFETY When Selecting a Handheld Multimeter

LF00AB/C SERIES VERY LOW DROP VOLTAGE REGULATORS WITH INHIBIT

Application Note. Double click System tray icon after service started. Click start/continue button

High-Speed Inter Connect (HSIC) Solution

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

L293B L293E PUSH-PULL FOUR CHANNEL DRIVERS. OUTPUT CURRENT 1A PER CHANNEL PEAK OUTPUT CURRENT 2A PER CHANNEL (non repetitive) INHIBIT FACILITY

Release Notes: PowerChute plus for Windows 95 and Windows 98

Agilent Infoline Web Services. Quick Reference Guide. Scan and use your phone to go to Infoline at

NI USB-6008/6009 OEM USER GUIDE

The Real Total Cost of Ownership of Your Test Equipment

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

Agilent OSS Wireless QoS Manager

LM134-LM234-LM334. Three terminal adjustable current sources. Features. Description

Agilent U1230 Series Handheld Digital Multimeters (DMMs)

Handheld portable appliance testers

Report on Government Information Requests

BTB04-600SL STANDARD 4A TRIAC MAIN FEATURES

TDA W Hi-Fi AUDIO POWER AMPLIFIER

W- Series. Features: WOB. Mechanical Data Case : Moulded plastic. Lead : Solder plated. Weight : 1.10 grams. Page <1> 15/07/08 V1.

DDR Memory Overview, Development Cycle, and Challenges

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

TN0023 Technical note

Agilent EEsof EDA.

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

NEW. EVEN MORE data acquisition and test stand automation

One Port Network Analyzer

LM833 LOW NOISE DUAL OPERATIONAL AMPLIFIER

.OPERATING SUPPLY VOLTAGE UP TO 46 V

Agilent OSS Customer-Centric Service Manager

Diode, Schottky SMB/DO-214AA. Page <1> 24/04/08 V1.1. Dimensions Inches (Millimeters)

Transcription:

Agilent 4338B Milliohm Meter 10 µω to 100 kω Technical Overview Introduction Ideal for precise measurements of extremely low resistances using an ac test signal, the Agilent Technologies 4338B suits bench-top applications that require flexible testing and reliable results. The milliohm meter satisfies system throughput demands for fast, high-quality measurements.

The Agilent 4338B Satisfy Your Needs for... High-quality testing Remove parasitics with error correction Achieve consistent results with 0.4% basic accuracy Verify test connections with contact check function Stabilize data with selectable measurement times and averaging Eliminate trigger timing errors with trigger delay Operating versatility Select from 5 impedance parameters Pick from 7 probes, test fixtures, and accessories Configure the instrument quickly with Save/Recall Reduce test complexity with automeasurement function Fast test throughput Get 34 ms/measurement speed Perform Pass/Fail testing with comparator function Operate remotely via the GPIB interface Use the built-in handler interface Key Parameters and Specifications Test frequency: 1 khz Impedance parameter sets: R, IZI-θ, R-L, R-X Basic accuracy: 0.4% Test current levels: 1 µa, 10 µa, 100 µa, 1 ma, 10 ma Error correction: Short compensation Display digits: 3, 4, or 5 digits (selectable) Save/recall: 10 instrument states Interfaces: GPIB and handler interface 2

Satisfy your need for high-quality testing Resolve data to 5 digits Make precise measurements with 0.4% basic accuracy Eliminate impedance calculations; select the parameter you need: R, IZI, θ, L, X Verify DUT performance under simulated operating conditions Perform dry contact testing with minimal test signal ( 20 mv) Obtain high-confidence testing with contact check function Test electromechanical devices Perform dry contact testing with low-level test signals Select from a variety of probes and test fixtures to fit your application Resolve measurements to 10 µω Test switches, cables, connectors, relays, and pc board traces Make precise ultra-low resistance measurements with the 4338B. Evaluate battery internal resistance Protect your investment with voltage protection on terminals (Max. 42 Vdc) Perform non-invasive testing with no effects on charge/discharge cycles Avoid polarization effects with an ac test signal System features for automation in manufacturing Maximize accuracy with error correction Automate testing with GPIB interface for computer control Reduce ground-loops with isolated handler interface Continue testing after ac power loss with non-volatile memory Perform pass/fail testing with comparator function (HIGH, IN, LOW) Use the milliohm meter for electromechanical contact testing. The 4338B is ideal for battery evaluation. 3

Agilent 4338B Specifications Measurement accuracy Table 1. Measurement accuracy (± % of reading) Measurement conditions The following test conditions apply for the data shown in Table 1: 1 1. Warm-up time: 30 minutes 2. Ambient temperature: 23 C ± 5 C 3. Test cable length: 0 meter 4. Short error correction performed. 5. Measurement time: LONG Measurement parameters/ranges Parameter Range R 10 µω to 100 kω X, IZI 10 µω to 100 kω (typical) L 10 nh to 10 H (typical) θ -180 to +180 1. Other test-condition data is available in the operation manual. 4

Measurement conditions and functions Test frequency: 1 khz ± 0.1% AC test signal level (rms current): 1 µa, 10 µa, 100 µa, 1 ma, 10 ma Maximum applied AC voltage: 20 mv peak Maximum DC voltage to BNC terminals: 42 V Ranging: Auto and hold Maximum cable length: 2 meters Trigger: Internal, manual, and external Delay time: 0 to 9999 ms in 1-ms steps Averaging: 1 to 256 Measurement time (typical): Short Medium Long 34 ms 70 ms 900 ms Other instrument functions Math functions: Deviation ( ) and percent deviation (% ). Short error correction: Eliminates measurement errors due to parasitic impedances in cables and test fixtures. Comparator: HIGH, IN, and LOW for primary and secondary parameters. Continuous memory: All instrument settings are automatically saved for up to 72 hours when power is lost or the instrument is turned off. Save/recall: 10 instrument states from non-volatile memory. Contact check: Detects contact failure. GPIB: Implementation of IEEE-488 for control and data. Handler interface: Negative logic and optically isolated; output signals: HIGH/IN/LOW, end-of-measurement, index, and alarm; input signals are keylock and external trigger. Physical characteristics Power: 90-132 Vac or 198-264 Vac. 47-66 Hz. 45 VA typical. Operating temperature: 0 C to 45 C Dimensions: 320(W) x 100(H) x 300(D) mm Weight: 4.5 kg 5

Test Fixtures/Accessories for the Agilent 4338B Milliohm Meter 16005-60011 Kelvin clip lead (large) Cable length, 0.4 meter. Jaws mate with large terminal devices. One lead supplied only. 16006-60001 pin-type probe lead Cable length, 0.4 meter. Spring-loaded probe tips for firm contact. Useful for manual contact measurements. One lead supplied only. 16005-60012 Kelvin IC clip lead (red clip) 16005-60014 Kelvin IC clip lead (black clip) Cable length, 0.4 meter. Small contacts for devices with fine leads. One lead supplied only. 16007-60001 alligator clip lead (red clip) 16007-60002 alligator clip lead (black clip) Alligator clip lead. Cable length, 0.4 meter. Each test lead has a separate alligator clip voltage and current terminal. One lead supplied only. 16143-60011 mating cable Interface between test leads and 4338B. Cable length, 0.5 meter. 16338A test lead kit Contains one each of the following: 16143-60011, 16005-60012/14, 16007-60001/2, carrying case. Contains two each of the following: 16005-60011 and 16006-60001. 6

Ordering information Agilent 4338B milliohm meter Furnished accessories: Power cable (Test fixtures are not furnished as standard.) Manual options 1 4338B-ABA U.S - English localization 4338B-ABJ Japan - Japanese localization 4338B-0BW Add service manual Cabinet options 4338B-1CM Rack mount kit 4338B-1CN Front handle kit (Rack flange handle kit is not compatible.) Calibration certificate option 4338B-1A7 ISO 17025 compliant calibration Test fixtures and accessories: 16005-60011 Kelvin clip lead (1 lead only) 16005-60012 Kelvin IC clip lead, red clip (1 lead only) 16005-60014 Kelvin IC clip lead, black clip (1 lead only) 16006-60001 pin-type probe lead (1 lead only) 16007-60001 alligator clip lead, red (1 lead only) 16007-60002 alligator clip lead, black (1 lead only) 16143-60011 mating cable (Requires 2 leads) 16338A test lead kit. Includes 16005-60011, 16005-60012/14, 16006-60001, 16007-60001/2 leads, 16143-60011 mating cable and carrying case. 1. Manual is not furnished as standard. 7

Web Resource www.agilent.com/find/lcrmeters Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Agilent Direct www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. Remove all doubt Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to www.agilent.com/find/removealldoubt www.agilent.com For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894-4414 Latin America 305 269 7500 United States (800) 829-4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Thailand 1 800 226 008 Europe & Middle East Austria 0820 87 44 11 Belgium 32 (0)2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0)10 855 2100 France 0825 010 700* *0.125 /minute Germany 01805 24 6333** **0.14 /minute Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0)20 547 2111 Spain 34 (91)631 3300 Sweden 0200-88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 (0)118 9276201 Other European Countries: www.agilent.com/find/contactus Revised: March 27, 2008 Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 1996, 2000, 2003, 2008 Printed in USA, April 10, 2008 5964-6183E