Kap.04-01 20.02.2006 12:35 Uhr Seite 1 Fire Pump mps 04



Similar documents
N/NH Truck-mounted fire pump series

IVECO CHASSIS DAILY 70C21D (4x2)

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

Unit 24: Applications of Pneumatics and Hydraulics

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

Unit 24: Applications of Pneumatics and Hydraulics

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

SUPERYACHT SPARES. Nozzles and portable monitors. / info@superyachtspares.com /

Fire Pump Plan Review March 2010

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

1300 MAXTRAK SPECIFICATION

SunMaxx Solar Filling Station Operating Instructions

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

WANJET. Sprayers. Wanjet sprayers has been produced since 1978.

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

Fuel Injection Pump, Rotary ( )

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Signature and ISX CM870 Fuel System

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Designed for multi-injector endurance testing, the

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

ECOCIAT. Domestic hot water heat recovery unit

Rail Canvas, folding top Rear panel Stip in window, left dto. right

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

Buy Karcher Parts Online: Need Technical Help? Call: Requests to:

INTERNATIONAL FIRE TRAINING CENTRE FIREFIGHTER INITIAL PUMPS AND PRIMERS. Throughout this note he means he/she and his means his/hers.

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Unit 24: Applications of Pneumatics and Hydraulics

HERZ-Thermal Actuators

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

Hydraulic Control Solutions

HVAC SYSTEM (HEATER, VENTILATOR, AND A/C)

COUNTERBALANCE VALVES

Number Wheeler P/N Description Set Rex P/N Notes Base 1 J Support, Right 1 J Support, Left 1 J Nut (M8)

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

Vertical selfpriming Side-Channel Pumps Type WPV

1013 E. The engine for agricultural equipment.

APPLIED PNEUMATICS AND HYDRAULICS H TUTORIAL HYDRAULIC AND PNEUMATIC CYLINDERS. This work covers part of outcome 2 of the standard Edexcel module.

Diesel Engine Driven Generators Page 1 of 6

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Product catalogue, pipe and sewer cleaning systems

MANTA Piston Distributor for Oil and Fluid Grease

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

Introduction to and Operation of Compressed Air Foam Systems (CAFS)

Evaporative emissions system

Automatic Fire Fighting Monitors

Horizontal Split Case Fire Pumpset Diesel Engine Driven

Electro-Pneumatic Bus Door Control Mechanism

Please keep these operating instructions in a safe place.

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

PARTS MANUAL EH12-2 ENGINE. Model. PUB-EP5713 Rev. 7/99

Condensate water pump with neutralisation system

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

Rexroth Hydraulic Pump A10VO Series User Manual

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Cooking at the Speed of light!

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Class A Foam Mixing and Application Equipment

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

912. The engine for construction equipment.

4" SUBMERSIBLE PUMPS

HEATER, AIR CONDITIONING AND VENTILATION

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Pneumatic control for robotics and industrial automation Author: Naresh Raghavan

Signature and ISX CM870 Electronics

Conlift1, Conlift2, Conlift2 ph+

FLSmidth ball mill for cement grinding

net flywheel power 74 kw - 99 hp max operating weight kg PAT DOZER BLADE CAPACITY 2.19 m 3

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

PART 2 FORKLIFT HYDRAULIC SYSTEM

Specifications for Volkswagen Industrial Engine

E - THEORY/OPERATION

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

Series TMM Axial Piston Motor. Technical Information

MEMBRANE VACUUM MINI PUMPS

Suction assembly for l IBC and 205 l drums mm suction tube Suction assembly for tanks mm suction tube.

TOYOTA ELECTRONIC CONTROL TRANSMISSION

Adjustment Data MAZDA Comprex D - RF-CX

S KID S TEER L OADER SK818-5 SK818-5 SK NET POWER SAE J ,7 kw. OPERATING WEIGHT kg. OPERATING CAPACITY 870 kg

Oil and Coolant Circulating Heating System. Model - OCSM

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Electric Rotary Actuator - On/Off or programmable control actuator

PC1130 Electric Air Compressor

Radial piston pumps type R and RG

Rules for Classification and Construction Additional Rules and Guidelines

REMOVAL AND INSTALLATION

Manual piston sampler...m 11

Power consumption (kw)

The Secret of Hydraulic Schematics. BTPHydraulics

Kompressoren. Adsorption Dryer AD

Cooling system components, removing and installing

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

1 Air-to-Air AfterCooling. 2 Engine Only. Capacity will vary with radiator size and use. of cab heater.

PC1131 Electric Air Compressor

Transcription:

Fire Pumps

FIRE PUMPS ZIEGLER fire fighting centrifugal pumps - proven high quality ZIEGLER fire pumps are powerful and wear-resistant centrifugal pumps, single or dual stage types, rugged, designed for dirty water, safe to operate and require very low maintenance. The simple functional construction, the easily legible gauges and the automatic engagement, priming and pressure control systems make the pump operation easy. Due to their design characteristics the ZIEGLER fire pumps can be adapted to foreign standards without problems. ZIEGLER fire pumps are made of highquality materials. The pump casing, diffusor, impellers and pump cover are of sea-water resistant light alloy. The pump shaft and split rings are made of stainless steel. Shaft sealing is by means of radial shaft sealing rings in an exchangeable sealing sleeve. The delivery outlets feature self-closing globe valves and ball valves in compliance with DIN-standard. The capacity of a built-in vehicle pump depends on the rpm and power of the vehicle engine, arrangement of the pump unit as well as the conditions under which water is fed to the pump. The pump charts on the following pages show performance curves measured under DIN requirements. ZIEGLER rear mounted pumps - rugged, powerful, extensible and of matured construction ZIEGLER fire pumps for rear or midship mounting are available with performances of 75 up to l/min, suited for the power of the various vehicle engines. The rugged and neat construction makes our pumps reliable and permits an unobstructed and functional design of the vehicle pump bay, also in cases when complicated wiring and ducting systems are necessary, e.g. when a proportioning system or monitors are fitted. ZIEGLER fire fighting centrifugal pumps are powerful: they have a high water performance at pressures of bar and higher and through the connectable high-pressure pump a pressure of up to bar can be reached. ZIEGLER fire fighting centrifugal pumps are uncomplicated and easy to operate: The fully automatic priming system TROKOMAT PLUS simplifies the operation of the pump enormously. On engaging the pump, priming takes place by operating the throttle only. A button is pushed and the ZIEGLER ANS-system provides automatic engagement of the PTO. Our automatic constant pressure governor TOURMAT D facilitates the work of the operator. Any change of pressure is instantly sensed and the pump performance is adjusted accordingly within fractions of a second. Our flow-controlled foam concentrate proportioning system PROFOMAT delivers exactly the desired concentration and provides simultaneous delivery of water or foam at the outlets. Our modular operation and control system is designed and constructed for a modern extensive pump unit. The performances of the pumps comply with DIN EN table 3. The max. performance figures are values that are reached under optimum conditions on our pump test floor with the most simple water duct on suction and delivery side. The pictures on the following pages may show details/versions that are available at additional costs. The art. Nos. refer to the basic version of the various pumps only. DIRECTION OF ROTATION: All ZIEGLER fire pumps are available with clockwise or anticlockwise rotation. Terms: HL: Pump with anticlockwise rotation when looking at the pump cover. HR: Pump with clockwise rotation when looking at the pump cover. Pumps without gear multiplication: the pump direction of rotation and the rotation of the PTO flange are identical. Pumps with gear multiplication: the pump direction of rotation is opposite to the direction the PTO flange. Please note that all dimensions and weights noted in our catalogue are approximate values. For orders please contact our local agent.

VEHICLE MOUNTED PUMPS MODULAR SYSTEM ZIEGLER fire pumps - modular system The renowned ZIEGLER pumps are not only available with various performance data. The fire pumps described on the following pages can be provided with various types of delivery outlets, with automatic engagement system and constant pressure control system as well as with various foam agent proportional systems. The ever increasing number of modern high-tech electronic plants increases the need for a fire fighting technology that keeps the secondary water damage as low as possible. To this effect we deliver our fire pumps already equipped for retrofitting a high-pressure pump. The well-proven and continuously improved ZIEGLER 3-stage highpressure pump is connected to the running normal-pressure pump via an electromagnetic clutch. The impellers of the HP-pump are not coupled to the shaft of the normal-pressure pump, i.e. they are not running when the normal-pressure pump is in operation. This reduces the wear to a minimum and permits a relatively easy retrofit. The operation of the high-pressure pump is simple: When the connection line between normal-pressure pump and highpressure pump is opened, the electromagnetic clutch is actuated. Now open the delivery outlet to highpressure reel. A thermal relief line to the tank prevents overheating in case the water delivery is interrupted. The unit can be operated in the following ways: Normal-pressure pump operation (HP-pump is not running) High-pressure pump operation (normal-pressure pump in circuit) Combined pump operation (both pumps are running) 3

1 17 1 17 1 17 x VDO x VDO MODULAR OPERATION AND CONTROL PANEL BKT BKT modular operation and control panel Modules: 7 5 3 1 max. bar max. 1 l/min 1/ 1/ Inhalt content 3/ 1/1 1/ 1/ Inhalt content 3/ 1/1 bar bar 1 1 1 3 5 bar -, -, -, -, -1 5 15 bar 5 15 5 bar 5 bar 3 RPM 5 I I I I I Module (control panel) Function 1 Main switch e.g. main switch, rpm counter Pump e.g. delivery pressure gauge, inlet pressure gauge, compr.-air gauge, pump switch ON/OFF, rpm +/- 3 High pressure e.g. high pressure gauge, pilot lamp, switch for rapid intervention Tourmat D e.g. automatic constant pressure governor 5 Water e.g. water tank level gauge, tank fill pressure gauge, switch for level adjustment Foam/light mast e.g. foam tank level gauge/tumbler switch, spotlight adjustment 7 Loudspeaker e.g. switch ON/OFF, hour counter N 3 RPM 5 bar 3 5 bar 1/ 1/ Inhalt content 3/ 1/1 15 5 bar 5 -, -, -, -, -1 5 15 bar 5 1 1 I I I bar 1 3 1 Module (control panel) Function 1 Main switch/ e.g. main switch, rpm-counter, Tourmat D Tourmat D, tank level gauge Pump e.g. delivery pressure gauge, inlet pressure gauge, compr.-air gauge, pump switch ON/OFF, rpm +/-, loudspeaker 3 High pressure/ e.g. high pressure gauge, pilot lamp, switch for foam rapid intervention, hour counter, foam OPEN/CLOSED A few basic functions are described here. Further additional functions are available on request.

PRIMING SYSTEM TROKOMAT PLUS TROKOMAT PLUS the automatic priming system that sets standards. Design and mode of operation: The ZIEGLER TROKOMAT PLUS is a modern reciprocating priming pump that carries out the priming action fully automatically, thus simplifying the pump operation to a minimum. The TROKOMAT PLUS operates without any auxiliary fluids such as water or oil. The TROKOMAT PLUS is switched on and off hydraulically by means of water pressure and no other control is required. The automatic process is carried out by very few parts (pic. 1): this makes the TROKOMAT PLUS reliable and increases its durability. Even at low engine rpm the TROKOMAT PLUS starts the suction action. This reduces wear on the engine, especially when starting from cold. The fully automatic priming system TROKOMAT PLUS consists of two completely separately working short-stroke reciprocating pumps. The pistons are pressed by a spring against an eccentric pump shaft. If the pump is engaged, the rotating eccentric pump shaft presses the pistons alternatively outwards. During this action air is drawn in from the suction line and housing. The springs press the pistons back towards the eccentric shaft. At the same time the intake air is compressed and routed to the atmosphere (pic. ). The water entering into the primed pump overcomes the spring pressure and thus disengages the pistons from the eccentric shaft. TROKOMAT PLUS switches off (pic. 3). If the pump pressure drops, the springs press the pistons against the eccentric shaft again and the priming resumes. The pump operator simply has to engage the pump and open the throttle. A further essential advantage: We install the ZIEGLER TROKOMAT PLUS in all vehicle fire pumps and in all portable pumps from type TS 5/ onwards, i.e. in all these types of pumps TROKOMAT PLUS parts and functions are identical. Picture 1 Picture Venting stroke Picture 3 3 7 1 Bearing flange Piston complete 3 Pressure spring Cylinder cap 5 Hexagon screw Inlet membrane 7 Outlet membrane Leaking water bore 9 Reengagement valve 3 7 1 Working position Eccentric 1 7 1 9 9 1 Stand-by position 1 3 5 Eccentric TROKOMAT PLUS is patented, patent No.: P 19 1.1. 7 3 3 Suction stroke 5

I I I 1/ 1/ Inhalt content 1 17 3/ 1/1 1/ 1/ Inhalt content 1 17 3/ 1/1 max. bar max. 1 l/min I bar bar 1 1 1 bar I bar bar bar 3 RPM 5 x VDO AUTOMATIC PTO ENGAGEMENT SYSTEM ANS AUTOMATIC PRESSURE GOVERNOR TOURMAT D 3 5 -, -, -, -, -1 5 15 5 5 15 5 7 1 5 Control module chassis Control module ZIEGLER 1 11 9 3 1. Control module TOURMAT D. Control module chassis 3. Fire pump. BKT control panel 5. Push button - main switch. Push button - pump ON/OFF 7. Push button - automatic TOURMAT D. Rotary knob - pump pressure 9. Pressure sensor. Rpm sensor 11. Chassis engine 1. Push button Gas +/- (manual adjustment) ANS/TOURMAT D with electronic injection EDC The pressure governor TOURMAT D (1) is an automatic pump pressure control for ZIEGLER centrifugal fire pumps (3). Pressure fluctuations which may occur due to different water delivery, e.g. when connecting or disconnecting nozzles, are instantly sensed and immediately corrected. The desired pump pressure is set by means of a rotary knob (). The max. possible quantity of water is shown in the pump performance diagram. All controls are clearly arranged on the BKT (operation and control panel) (). Mode of operation: When the main switch (5) (option) and the pump ON button () are pressed, the PTO is engaged via the fully automatic ZIEGLER ANS system. Now the TOURMAT D electronic system can be activated by pressing the button Automatic (7). The preset pressure (rotary knob) () is compared with the pressure measured at the pump (9). If the pump pressure is less than 3 bar and the water head is not built-up or raptured respectively, suction is started. The electronic system switches over to rpm control and the optimum pump rpm for suction is set. The rpm sensor mounted on the pump flange () shows the actual value of the pump rpm. If the pressure of 3 bar is exceeded, the control circuit acts as pressure governor. If the pump pressure is lower or higher than the set pressure, the control circuit directly acts on the electronic speed adjustment of the vehicle () until the desired pressure is reached. If the automatic system (7) or the pump is switched off (), the rpm is automatically adjusted to idling. If the automatic system is in operation and one of the buttons rpm+/- (1) is pressed, the TOURMAT D (automatic) is switched off. The pressure adjustment is now done manually. To avoid operating errors the pump rpm can be changed only if the pump is engaged and the handbrake is actuated. This is also the case in emergency operations. Advantages: Due to the electronic system of TOURMAT D the pump operator does not need to check or adjust controls. The pressure is constant even if water delivery is changed.

AUTOMATIC PTO ENGAGEMENT SYSTEM ANS FREQUENCY GOVERNING SYSTEM TOURMAT F ANS system This is an electronic system for switching on the generator. By means of a push button all processes for switching on and off the generator run automatically. Irrespective of the standard PTO engagement system in the driver s cab the generator can be engaged in the generator box. Description of the PTO engagement system ANS: 3 EIN/AUS ANS and TOURMAT F with electronic injection pump TOURMAT F (1) is a fully automatic frequency governing system with a constant frequency - usually 5 Hz - for use with a built-in generator (7). The controls are mounted in the generator box (3). The push button () generator ON/OFF activates the electronic system, which automatically engages the PTO. The rpm sensor (5) in the PTO flange signals to the control that the generator is in operating condition. The frequency governor is now activated via the electronic rpm adjustment () of the vehicle. In this way a constant power supply is ensured even if the consuming devices are changed. In case of an emergency an alteration of the generator frequency can take place in the driver s cab in vehicles with electronic speed adjustment. When the generator is switched off the rpm is automatically adjusted to idling and the PTO is disengaged. Control module chassis 1. Control module TOURMAT F. Control module chassis 3. Generator box. Push button - generator ON/OFF 5. Rpm sensor. Chassis engine 7. Built-in generator Control module ZIEGLER 5 1 7 7

FOAM PROPORTIONING SYSTEM ZZ ZIEGLER foam proportioning units - the most modern and extensive range on the market! ZZ ZIEGLER ejector pump proportioner for the feed water line A decrease of the pipe diameter causes a negative pressure that draws in the foam agent. Advantages: +simultaneous delivery of water or foam at the outlets +independent of source of water supply to the pump +foam can be drawn also from external sources Disadvantages: -pressure loss of 3% -the throughput of the proportioner must be identical with the consumption of the consuming devices -sensitive to counter-pressure resulting from friction % % 7 % % 5 3 1 1. Water tank. Foam tank 3. Suction line water tank. Suction line foam tank 5. Fire pump. Delivery outlets 7. Z proportioner. Pressure hose

FOAM PROPORTIONING SYSTEM ZPV ZPV ZIEGLER pump proportioner ZPV is a proportioning unit that works on the ejector pump principle. The foam concentrate is drawn in and added to the water on the suction side of the pump. The quantity of foam concentrate is set by means of a dosage lever. ZIEGLER PVs are available in the following sizes: 5, 75,, 15,, 3,, 5 and l/min. Advantages (ejector pump principle): +thorough mixing +independent of counter-pressure +simple, reliable and low-priced proportioning system Disadvantages (ejector pump principle): -changes in volume of flow require manual resetting -when using water from a hydrant the delivery pressure must be.5 times higher -complete pump unit must be flushed -decrease of delivery performance due to by-pass line 9 5 15 l/min 1. Water tank. Foam tank 3. Suction line water tank. Suction line foam tank 5. Fire pump. Delivery outlets 7. Pump proportioner. By-pass line 9. Dosage regulating device 5 7 3 1 9

FOAM PROPORTIONING SYSTEM ZPV MAD ZPV MAD ZIEGLER pump proportioner with a mechanic-automatic dosage unit The unit consists of a flow controlled proportioning governor and a proportioner. With this unit an automatic control of the quantity of foam concentrate is achieved. 3 different proportioning rates between 1 and % can be set. MAD reacts quickly on changes of flow and always delivers exactly the required quantity of foam concentrate to the ejector pump for maintaining the selected percentage of foam. ZPV MAD is available in two sizes: - ZPV MAD 3 for flow rates of - 3 l/min - ZPV MAD 5 for flow rates of - 5 l/min, (even up to l/min if rate is reduced to %) 9 1% 3% % Sp 5 7 3 1 1. Water tank. Foam tank 3. Suction line water tank. Suction line foam tank 5. Fire pump. Delivery outlets 7. Pump proportioner. By-pass line 9. Mechanic-automatic dosage unit MAD. Proportioning rate setting lever

FOAM PROPORTIONING SYSTEM ZPV EAD ZPV EAD ZIEGLER pump proportioner with an electronic-automatic dosage unit The unit consists of a magneticinductive flow meter in the pressure line of the fire pump, a further magnetic-inductive flow meter as well as an electrically controlled dosage unit in the foam suction line of the pump proportioner. The foam concentrate is aspirated via a pump proportioner and fed into the suction line of the fire pump. A SPS controlling device evaluates the signals from the flow meters and adjusts the dosage unit in accordance with the preset proportioning rate. Range of water flow: - - l/min Range of foam flow: - 1-7 l/min Proportioning rates: - 1% - % 3 % % 1 % SP 9 SPS M 11 1. Water tank. Foam tank 3. Suction line water tank. Suction line foam tank 5. Fire pump. Delivery outlets 7. Pump proportioner. By-pass line 9. Flow meter water/foam mixture. Dosage unit 11. Flow meter foam concentrate 5 7 3 1 11

FOAM PROPORTIONING SYSTEM PROFOMAT PROFOMAT The self-regulating pressure proportioning system The PROFOMAT pressure proportioning system is used for automatic and exact proportioning of foam concentrate over the full range of outgoing flows and pressures of water delivery by fire pumps. The PROFOMAT system consists of one or several proportioners, dosage unit with setting dial, pressure regulator, non-return valve to the foam tank and a foam concentrate pump. The proportioner/s is/are mounted on the delivery side of the pump. The delivery water flows through the proportioner/s. By means of the dosage unit the desired proportioning rate for the foam concentrate can be set manually or by remote control. The foam concentrate is pumped to the proportioner by the foam concentrate pump via a pressure regulator. The pressure of the foam concentrate must be at least bar higher than the corresponding delivery pressure. In the pressure regulator the difference between the water pressure and the foam concentrate pressure is mechanically controlled by means of a membrane. The foam concentrate flowing through the pressure regulator and the dosage unit is mixed to the delivery water via the proportioners at a preselected rate. Advantages/characteristics: a) Irrespective of the flow and pressure of the water delivered by the fire pump the proportioning rate remains constant as long as the pressure of the foam concentrate is at least bar higher than the water pressure. The performance of the fire pump and the foam concentrate pump must only meet the requirements of the largest consuming device (monitor). b) If necessary, a proportioner can be provided for each consuming device (delivery outlets, monitors, body/ ground protection unit etc.). In such cases the proportioner is designed for the max. delivery required. c) If individual proportioners are provided for each consuming device, they can, independed of each other, be fed with water or foam concentrate solution at variable proportioning rates, suitable for each consuming device. d) Continuous adjustment of the proportioning rate is possible. e) As no moving parts are used the system is resistant to wear and almost maintenance-free. Applications: - water/foam vehicles for refineries and for protection of industrial plants - decentralized proportioning in stationary foam systems in refineries and tank farms 11 9 9 9 7 5 1 3 1. Water tank. Foam tank 3. Suction line water tank. Suction line foam tank 5. Fire pump. Delivery outlets 7. Foam concentrate pump. Proportioning system PROFOMAT 5 9. Proportioning system PROFOMAT 1. Water delivery line 11. Foam delivery line 1

COMPRESSED AIR PROPORTIONING SYSTEMS AND COMPRESSED AIR FOAM SYSTEMS ZIEGLER FOAM SYSTEM (Class A) ZIEGLER POWER FOAM BASIC NA (Class A and Class B as required) ZIEGLER POWER FOAM PRO (Class A and Class B as required) Max. Foam agent Max. Compressor Remarks ZIEGLER unit flow pump adjustable delivery new delivery delivery proportioning air standard water/foam max. foam rate (nominal output) DIN V 13 Foam System 1 E 1 l/min 9, l/min % without DZA /. -. Foam System E 1 l/min l/min % without DZA /. - 3. DZA 1 /. - 1.5 Power Foam 1 l/min 9, l/min % 1 l/min DLS Basic NA 7 bar Power Foam 1 l/min 19 l/min % 5 l/min DLS Pro 1 bar Power Foam l/min 19 l/min % 5 l/min DLS 1 Pro bar 13

Kap.-1 9.3.5 :5 Uhr Seite 1 FOAM SYSTEM 1 E COMPRESSED AIR PROPORTIONING SYSTEM DZA /. -. Foam can be generated with use of foam nozzles (S - S and M - M respectively) and universal or class B foam agent. The system can be used in all types of vehicle with a FPN or portable pump. We recommend vehicles with FPN and integrated tank. The system can be used with: TSF-W with TS /, vehicles with FPN - (e.g. LF /) up to FPN - (e.g. LF /1 or TLF 1). Foam delivery can take place via one or more hoses or a monitor. Fog nozzles have turned out to be the most advantageous nozzles when using class A foam. The use of fog nozzles supports the generating of small drops. ZIEGLER FOAM SYSTEM 1 E consists of: Foam pump (9. l/min) Foam supply from cans, from onechamber foam agent tank (e.g. l) or from two-chamber tank (e.g. 5 l/ l) Flow meter water Flow meter foam Operating elements (display and emergency operation) Display indicating: - Water flow - Foam flow - Proportioning rate adjustable during action in % - Total water consumption - Total foam consumption tting! i f o r t e rr also fo FULFILLS EVEN THE REQUIREMENTS OF A DZA /, - 1, (NOMINAL PERFORMANCE l/min) Manual emergency operation for foam via rotary button Connection of the foam unit to the pump pressure line Electric wiring Special foam can lid with connections for ventilation and with foam filter Inlet and outlet via 1 size B Storz Operating elements on pump operating panel with tank change-over in case of a zwo-chamber tank Technical data: Foam pump: 9. l/min Nominal performance: l/min at a proportioning rate of. -.% Volume flow: up to 1 l/min (max. proportioning rate =.%) Proportioning rate:. up to % (max. volume flow reduction at % = 1 l/min) DZA /.-. Capacity foam pump Proportioning rate % ZIEGLER FOAM SYSTEM 1 E for generating class A foam with class A foam agent and nozzles (CM nozzles, fog nozzles etc.) with a nominal performance of l/min at a proportioning rate of. -.%. A delivery of up to 1 l/min water/ foam mixture is possible. The proportioning rate is adjustable irrespective of the amount of water delivered. 7.. 5.. 3. l/min -. %. 1. 3 5 7 9 1 1 13 Qw (l/min) 1

Kap.-15 9.3.5 :51 Uhr Seite 15 FOAM SYSTEM E COMPRESSED AIR PROPORTIONING SYSTEM DZA /. - 3. ZIEGLER - FOAM SYSTEM E for generating class A foam with class A foam agent and nozzles (e.g. CM nozzles, fog nozzles etc.) with a nominal performance of l/min at a proportioning rate of. - 3.%. A delivery of up to 1 l/min water/ foam mixture is possible. The proportioning rate is adjustable irrespective of the amount of water delivered. Foam can be generated with the use of foam nozzles (S - S and M - M respectively) and universal or class B foam agents. The unit is suitable for use in any type of vehicle with a FPN. The system can be used in vehicles with FPN - (e.g. LF /) up to FPN - (e.g. LF /1 or TLF 1). Display indicating: - Water flow - Foam flow - Proportioning rate adjustable during action in % - Total water consumption - Total foam consumption Manual emergency operation for foam via rotary button Electric wiring outlets size B Storz Operating elements on pump operating panel Either up to nozzles (C, M, S) or a monitor can be used. Fog nozzles have turned out to be the most advantageous nozzles for use with class A foam. They support the generating of small drops. ZIEGLER FOAM SYSTEM E consists of: Foam pump ( l/min) Foam supply from two-chamber foam agent tank (e.g. 5/ l) Flow meter water Flow meter foam Connection of the foam unit to the pump pressure line Operating elements (display and emergency operation) Technical data: Foam pump: l/min Nominal performance: l/min at a proportioning rate of. - 3.% Volume flow: up to 1 l/min (max. proportioning rate = 1.5% Proportioning rate:. - % (max. volume flow reduction at % = l/min) 7.. 5.. l/min - 3. % 3.. Qw (l/min) 15 17 15 1 1 13 1 1 9 7 5 3 1. FULFILLS EVEN THE REQUIREMENTS OF A DZA 1 /. - 1.5 (NOMINAL PERFORMANCE 1 l/min) Proportioning rate % DZA /.-3. Capacity foam pump

content 1/ content bar POWER FOAM BASIC NA B A POWER FOAM BASIC NA 1/ 1/ 3/ Inhalt 1/1 Inhalt 1/ 3/ 1/1 ON OFF ZIEGLER POWER FOAM BASIC NA With ZIEGLER units with CAFS a throw of up to 3-5 m is possible. The performance of the compressor is 1 l/min at 7 bar. The volume flow is up to 1 l/min water/foam mixture at a proportioning rate of. - % and compr.-air foam with additionally up to 1 l/min compr.-air. Foam quality adjustable: Volume ratio water/foam mixture to air wet: 3 Vv dry: < Vv 15 The unit is operated with a working pressure of up to max. 7 bar. The proportioning is adjustable from. to % via a push button and adjusts automatically to the varying volume flows. The system is very clear and easy to operate. By pushing a button the unit, also during operation, can be switched over from water to CAFS action or the other way round. Simultaneous use of 3 size B nozzles with class A foam or 3 size C nozzles with compr.-air foam and the use of a monitor respectively is possible without problems. Other combinations such as water delivery via delivery outlets with size C hoses and simultaneous CAFS action with one outlet are also possible. All CAFS components are found in one and the same equipment locker. The system requires very little maintenance. In case of service the complete BKT (operating and control panel) can be swung to the side and all important parts are clearly shown. The unit is of such a low weight that it can be installed in every ZIEGLER LF /. The ZIEGLER Power Foam Basic NA can, from the performance spectrum point of view, be used in every vehicle with a FPN - or a FPN -. COMPRESSED AIR FOAM DLS/CAFS DLS COMPRESSED AIR PROPORTIONING SYSTEM DLS (DIN V 13) Performance: - l/min water/foam mixture - Proportioning rate =. -.% - 1 l/min compressed air at 7 bar - Volume ratio air/foam = 3-15 1

DLS COMPRESSED AIR FOAM DLS/CAFS Water line 1 Foam pump 3 Fire pump Foam line Compressor 5 Control technique wet/dry 9 7 Air line Air regulating valve Pump operation panel with POWER FOAM BASIC NA Water/foam/air mixture Schematic picture DLS/CAFS for POWER FOAM BASIC NA Technical data: Foam pump: max. 9. l/min at 17 bar Compressor performance: max. 1 l/min at 7 bar Working pressure of system: 7 bar Flow meter - Measuring range: -1 l/min Drive of compressor: PTO, via belt drive with magneto coupling Power required by compressor: max. 9 kw Other configurations of ZIEGLER class A foam systems and DLS units with ZIEGLER centrifugal fire pumps are possible! We will be pleased to give you further information. POWER FOAM BASIC NA 17

Auslastung Max Fluß l/min % Wasser Schaum Auswahl Achtung! Betriebsanleitung lesen und beachten. Schaummittel muß zur Luftzumischung gefördert werden! Schaumzumischung am ARC regeln. HVC TEMP Öltemperatur Luft bereit HVC HOURS Betriebsstunden Keine Blindkupplungen an den CAFS-Abgängen anbringen! POWER FOAM PRO 1 POWER FOAM PRO + - 1/ 1/ Inhalt content B 3/ 1/1 1/ 1/ Inhalt content A 3/ 1/1 ON Total Auswahl % SCHAUM ZUMISCHUNG Achtung! Betriebsanleitung lesen und beachten. Luftmengenanzeige ON LUFT- ZUMISCHUNG 15 5 bar 5 3 AIR / LUFT WATER / WASSER ZIEGLER POWER FOAM PRO 1 for the generation of class A foam up to 1 l/min at a proportioning rate of.1 -% and compr.-air foam with additionally up to 5 l/min compr.-air. Foam quality adjustable for PRO 1 and PRO : Volume ratio water/foam mixture to air wet: 3 Vv dry: < Vv 15 The set proportioning rates automatically adjust to the varying volume flows. ZIEGLER POWER FOAM PRO 1unit is suitable for installing in every vehicle with a FPN - or a FPN -. Simultaneous use of size C nozzles with class A foam or compr.-air foam and the use of a monitor respectively is possible. ZIEGLER POWER FOAM PRO 1 system consists of: ZIEGLER centrifugal fire pump for delivery of the necessary extinguishing water Foam proportioning system with foam pump, flow meter, foam tanks, foam agent injection nozzle, electropneumatic selector valve for choice of foam agent with flush adjustment, foam agent filter and non-return valves Operating panel with indicator for current volume flow, proportioning rate, water and foam agent consumption as well as utilization HVC compressor with separator tank and oil cooler Compr.-air control valve with manual emergency control Automatic measuring and control unit for the air volume with air volume indicator ARC control unit for foaming control (wet/dry) Technical data: Geared foam pump: 19 l/min at 17 bar Compressor performance: 5 l/min at bar Compressor drive: PTO, via belt drive with magneto coupling Flow meter measuring range: -1 l/min Foam pump engine: V,.5 kw Power required for compressor: max. 37 kw COMPRESSED AIR FOAM DLS/CAFS COMPRESSED AIR PROPORTIONING SYSTEM DLS (DIN V 13) Performance: - l/min water/foam mixture - Proportioning rate =.3 -% - 5 l/min compr.-air at bar - Volume ratio air/foam = 3-15 1

POWER FOAM PRO Water line 1 Foam pump 3 Fire pump Foam line Compressor 5 Control technique wet/dry 9 7 Air line Air regulating valve Pump operation panel with POWER FOAM PRO Water/foam/air mixture Schematic picture DLS/CAFS for POWER FOAM PRO ZIEGLER POWER FOAM PRO for the generation of class A foam up to l/min at a proportioning rate of.1 -% and compr.-air foam with additionally up to 5 l/min compr.-air. Foam quality adjustable for PRO 1 and PRO : Volume ratio water/foam mixture to air wet: 3 Vv dry: < Vv 15 The set proportioning rates adjust automatically to the varying volume flows. ZIEGLER POWER FOAM PRO system is suitable for installation in every vehicle with a FPN - or a FPN -. Simultaneous use of size C nozzles with class A foam or compr.-air foam and additionally use of a monitor is possible. ZIEGLER POWER FOAM PRO system consists of the same components as the POWER FOAM PRO 1system, but with the following deviating performance figures: Compressor performance: 5 l/min at bar Flow meter.5 measuring range: - 5 l/min Please contact us for further information! COMPRESSED AIR PROPORTIONING SYSTEM DLS (DIN V 13) Performance: - 1 l/min water/foam mixture - Proportioning rate =.3-1% - 5 l/min compr.-air at bar - Volume ratio air/foam = 3-15 19

HIGH PRESSURE EXTINGUISHING UNITS The principle Efficient fire fighting with optimum use of the extinguishing power of water. Through the fine atomization an almost complete vaporization of the water is reached. The oxygen concentration and the oxygen supply respectively is obstructed and an optimum cooling effect is obtained. Range of application The high pressure extinguishing device HDL is used when fighting fires of class A and B. For fires of class A (hard substances fires) the classical extinguishing agent water is predominantly used. Depending on requirement and situation a changeover to foam can take place through admixing of foam agent and the quick and easy engagement of the rapid intervention unit. Foam is an excellent medium for extinguishing fires of combustible liquids (fire class B) and prevents possible backfires at hard substances fires. Advantages: - Compact rapid intervention unit - Optimum use of the cooling effect of water - Suffocating effect through water vaporization - Minimum water consumption, max. 5 l/min - Reduction of water damage - Admixing of foam agent only when necessary - Multifunctional in connection with further components ( Ölblitz road cleaner, mud collector, etc.) High pressure extinguishing device HDL 5 Mobile unit with tank of 15 l with rugged steel pipe frame/chassis, canister holder and push bar. Drive by -cyl. V petrol engine, 13. kw (1 HP). Oil pressure control, vibrationresistant starter battery 1 V/ Ah, electric starter, emergency pull starter. Exchangeable canister tank of 5 l for standard petrol. Power transmission through oil bath lubricated reduction gear 3:15 rpm, 3-cyl. piston pump, oil bath lubricated, with wearresistant ceramic plungers, stainless steel valves, chem. nickel-plated, corrosion-resistant brass cylinder head. Water filter with stainless steel sieve. High pressure control valve with pressure relief for closed extinguishing pistol. Overheating protection through a thermovalve 5 C. Glycerol damped manometer - bar (class 1.). Hose drum, rotating under full pressure, for m of armored hose ( bar) with crank, hose reel window and brake. Foam agent suction device 3% with shut-off valve. With 5 m of armored hose ( bar), hose detwisting joint, self-closing lockable extinguishing pistol. Combination extinguishing adaptor (corrosionresistant) adjustable from high pressure fog to low-expansion foam. Water delivery: max. l/min Working pressure: bar Extinguishing water pressure: 5 bar Dim. (LxWxH): 1x7x1 mm Weight (empty): 177 kg...5931 5931 593 High pressure extinguishing device HDL 5 Portable pump version with tank of 15 l * as art. No. 5931, but without chassis, canister holder and push bar. With frame for portable pump rail. Carrying handles and battery charging socket complying with DIN 19. Dim. (LxWxH): 115x5x5 mm Weight (empty): 13 kg...593 High pressure extinguishing device HDL 17 S Built-in version without tank with rugged mounting platform and metal rubber buffers for permanent mounting. Drive by 1-cyl. petrol engine 9. kw. Oil pressure control, vibrationresistant pull starter. Tank of 5 l for standard petrol. 3-cyl. piston pump, oil-bath lubricated, with wear-resistant ceramic plungers, stainless steel valves. Chem. nickel-plated, corrosionresistant brass cylinder head. Water filter with stainless steel sieve. High pressure control valve with pressure relief for closed extinguishing pistol. Glycerol damped manometer - 5 bar (class 1.). Hose drum, rotating under full pressure, with 5 m of high pressure hose (3 bar) with crank and brake. Foam agent suction device 3% with shut-off valve. With hose detwisting joint, self-closing lockable extinguishing pistol. Combination extinguishing adaptor (corrosion-resistant) adjustable from high pressure fog to low-expansion foam. Water delivery: max. 1 l/min Working pressure: 1 bar Extinguishing water pressure: 17 bar Dim. (LxWxH): x55x5 mm Weight (empty): 75 kg...593 Long-throw high pressure nozzle for high pressure extinguishing device * screw-on nozzle for effective throws of up to 7 m....593 Further high pressure extinguishing devices on request! * not illustrated

AUTOMATIC WATER SUPPLY SYSTEM AWZ 7 3 1 5 1. Non-return valve. Non-return valve 3. Tank. Suction inlet 5. Hydrant inlet. Butterfly valve 7. Fire pump AWZ automatic water supply system Purpose: The purpose of the AWZ system is to supply the pump with water from a hydrant. It automatically feeds the pump with hydrant water, stopping the flow from the tank. A collecting head or transition piece at the suction inlet is not needed. Contraction of the hose when the throughput of water is too high is also prevented. Function: The system consists of two springloaded non-return valves. The valve (1) is placed in the tank suction line and has a very low opening pressure. The valve () is placed in a branch to the tank suction line, that ends between valve (1) and the pump. The valve () has a strong spring and is therefore not opened until the difference in pressure is 1 bar. Water supply from the tank: When water is supplied from the tank the valve (1) in the tank suction line opens. The valve () in the feed line from the hydrant remains closed due to the high spring tension. In this way no air is drawn in via the valve (). Water supply from hydrant: When the feed line from the hydrant is pressurized so that the water pressure in front of the valve () increases to 1.5 bar or above, the valve () opens and water flows from the hydrant into the tank suction line. Through this water flow excess pressure is built up in the tank suction line and the valve (1) closes. In this way there is an automatic switch-over from supply from the water tank to supply from the hydrant. Performance: The quantity of water fed via the AWZ system depends mainly on the capacity of the hydrant. The decisive factors are the nominal width and the existing water pressure. At a flow pressure of 1.5 bar to. bar in front of the valve () up to 1 l/min can be reached. 1

CENTRIFUGAL FIRE PUMP FPN - 75 - H FPN - 75 - H Approv. No. AZ 73 ZIEGLER fire pump (rear-mounted) for vehicle PTO of kw (5 HP) onwards 1 1 1 1 75 1 1 1 1 points of guarantee: geod. 3 m geod. 7.5 m FPN - 75 - H and FPH - 5-3 All FPN can be retrofitted with a HP-pump. Please see page 3, HP-pump. (Test floor performance complying with DIN EN ) geod. = 7.5 m geod. =. m geod. =.5 m geod. = 3. m geod. = 1.5 m Nominal pump output: 75 l/min at bar and 3 m geod. Max. pump output: (test floor performance complying with DIN EN ) 19 l/min at bar and 3 m geod. l/min at bar and 1.5 m geod. Drive: Via joint shafts from the PTO of the vehicle Basic fittings: Dual stage centrifugal fire pump, clockwise or anticlockwise rotation, with 1 size A suction inlet, size B delivery outlets, 1 connection for rapid intervention line, 1 connection for tank fill line, 1 connection for tank suction line (lockable by means of a butterfly valve) TROKOMAT PLUS, fully automatic Gauges and controls: Modular operation and control panel BKT, please see page Colour: Silver RAL 9 Dim. (LxWxH): 75x75x mm Weight: 7 kg Additional fittings (options): more delivery outlets, connection for another rapid intervention line, monitor connection, fitting of a pump proportioner Additional systems (options): ANS, TOURMAT D, AWZ system, TROKOMAT shut-off, draining device Anticlockwise FPN - 75 - HL...1935 Clockwise FPN - 75 - HR...195 Anticlockwise FPN - 75 - HHL...155 Clockwise FPN - 75 - HHR...155

CENTRIFUGAL FIRE PUMP FPN - - H FPN - - H Approv. No. AZ 3 ZIEGLER fire pump (rear-mounted) for vehicle PTO of kw (5 HP) onwards Nominal pump output: l/min at bar and 3 m geod. Max. pump output: (test floor performance complying with DIN EN ) 19 l/min at bar and 3 m geod. l/min at bar and 1.5 m geod. Drive: Via joint shafts from the PTO of the vehicle Basic fittings: Dual stage centrifugal fire pump, clockwise or anticlockwise rotation, with 1 size A suction inlet, size B pressure outlets, 1 connection for rapid intervention line, 1 connection for tank fill line, 1 connection for tank suction line (lockable by means of a butterfly valve) TROKOMAT PLUS, fully automatic Gauges and controls: Modular operation and control panel BKT, please see page Colour: Silver RAL 9 Dim. (LxWxH): 75x75x mm Weight: 7 kg Additional fittings (options): more delivery outlets, connection for another rapid intervention line, monitor connection, fitting of a pump proportioner Additional systems (options): ANS, TOURMAT D, AWZ system, TROKOMAT shut-off, draining device Anticlockwise FPN - - HL... 1935 Clockwise FPN - - HR... 195 Anticlockwise FPN - - HHL... 155 Clockwise FPN - - HHR... 155 1 1 1 1 1 1 1 1 points of guarantee: geod. 3 m geod. 7.5 m (Test floor performance complying with DIN EN ) geod. = 7.5 m geod. =. m geod. =.5 m geod. = 3. m geod. = 1.5 m FPN - - H and FPH - 5-3 All FPN can be retrofitted with a HP-pump. Please see page 3, HP-pump. 3

CENTRIFUGAL FIRE PUMP FPN - 15-1 H FPN - 15-1 H Approv. No. AZ 153 ZIEGLER fire pump (rear-mounted) for vehicle PTO of 1 kw (15 HP) onwards total delivery pressure p ges (bar) 1 1 1 1 3 9 geod. = 7.5 m 1 15 geod. =. m geod. =.5 m geod. = 3. m geod. = 1.5 m 1 7 3 Nominal pump output: 15 l/min at bar and 3 m geod. Max. pump output: (test floor performance complying with DIN EN ) 5 l/min at bar and 3 m geod. l/min at bar and 1.5 m geod. Drive: Via joint shafts from the PTO of the vehicle Basic fittings: Single stage centrifugal fire pump, clockwise or anticlockwise rotation, with 1 size A suction inlet, size B delivery outlets, 1 connection for rapid intervention line, 1 connection for tank fill line, 1 connection for tank suction line (lockable by means of a butterfly valve) TROKOMAT PLUS, fully automatic Gauges and controls: Modular operation and control panel BKT, please see page Colour: Silver RAL 9 Dim. (LxWxH): x9x5 mm Weight: 9 kg points of guarantee: geod. 3 m geod. 7.5 m (Test floor performance complying with DIN EN ) Additional fittings (options): more delivery outlets, connection for another rapid intervention line, monitor connection, fitting of a pump proportioner FPN - 15-1 H and FPH - 5-3 All FPN can be retrofitted with a HP-pump. Please see page 3, HP-pump. Additional systems (options): ANS, TOURMAT D, AWZ system, TROKOMAT shut-off, MAD 3, draining device Anticlockwise FPN - 15-1 HL...197 Clockwise FPN - 15-1 HR...19 Anticlockwise FPN - 15-1 HHL...155 Clockwise FPN - 15-1 HHR (rotation, please see )...155

CENTRIFUGAL FIRE PUMP FPN - 15 - H FPN - 15 - H Approv. No. AZ 153 ZIEGLER fire pump (rear-mounted) for vehicle PTO of kw (1 HP) onwards Nominal pump output: 15 l/min at bar and 3 m geod. Max. pump output: (test floor performance complying with DIN EN ) l/min at bar and 3 m geod. 5 l/min at bar and 1.5 m geod. Drive: Via joint shafts from the PTO of the vehicle Basic fittings: Dual stage centrifugal fire pump, clockwise or anticlockwise rotation, with 1 size A suction inlet, size B delivery outlets, 1 connection for rapid intervention line, 1 connection for tank fill line, 1 connection for tank suction line (lockable by means of a butterfly valve) TROKOMAT PLUS, fully automatic Gauges and controls: Modular operation and control panel BKT, please see page Colour: Silver RAL 9 Dim. (LxWxH): x9x5 mm Weight: 115 kg Additional fittings (options): more delivery outlets, connection for another rapid intervention line, monitor connection, fitting of a pump proportioner 1 1 1 1 3 9 1 15 1 7 3 points of guarantee: geod. 3 m geod. 7.5 m (Test floor performance complying with DIN EN ) geod. = 7.5 m geod. =. m geod. =.5 m geod. = 3. m geod. = 1.5 m Additional systems (options): ANS, TOURMAT D, AWZ system, TROKOMAT shut-off, MAD 3, draining device Anticlockwise FPN - 15 - HL... 199 Clockwise FPN - 15 - HR... 197 Anticlockwise FPN - 15 - HHL... 1559 Clockwise FPN - 15 - HHR... 1555 FPN - 15 - H and FPH - 5-3 All FPN can be retrofitted with a HP-pump. Please see page 3, HP-pump. 5

CENTRIFUGAL FIRE PUMP FPN - - 1 H FPN - - 1 H Approv. No. AZ 3 ZIEGLER fire pump (rear mounted) for vehicle PTO of 1 kw (15 HP) onwards 1 1 1 1 3 9 geod. = 7.5 m geod. =. m geod. =.5 m geod. = 3. m geod. = 1.5 m 1 15 1 7 3 Nominal pump output: l/min at bar and 3 m geod. Max. pump output: (test floor performance complying with DIN EN ) 5 l/min at bar and 3 m geod. l/min at bar and 1.5 m geod. Drive: Via joint shafts from the PTO of the vehicle Basic fittings: Single stage centrifugal fire pump, clockwise or anticlockwise rotation, with 1 size A suction inlet, size B delivery outlets, 1 connection for rapid intervention line, 1 connection for tank fill line, 1 connection for tank suction line (lockable by means of a butterfly valve) TROKOMAT PLUS, fully automatic Gauges and controls: Modular operation and control panel BKT, please see page Colour: Silver RAL 9 Dim. (LxWxH): x9x5 mm Weight: 9 kg points of guarantee: geod. 3 m geod. 7.5 m (Test floor performance complying with DIN EN ) Additional fittings (options): more delivery outlets, connection for another rapid intervention line, monitor connection, fitting of a pump proportioner FPN - - 1 H and FPH - 5-3 All FPN can be retrofitted with a HP-pump. Please see page 3, HP-pump. Additional systems (options): ANS, TOURMAT D, AWZ system, TROKOMAT shut-off, MAD 3, draining device Anticlockwise FPN - - 1 HL...197 Clockwise FPN - - 1 HR...19 Anticlockwise FPN - - 1 HHL...155 Clockwise FPN - - 1 HHR...155

CENTRIFUGAL FIRE PUMP FPN - - H FPN - - H Approv. No. AZ 3 ZIEGLER fire pump (rear-mounted) for vehicle PTO of kw (1 HP) onwards Nominal pump output: l/min at bar and 3 m geod. Max. pump output: (test floor performance complying with DIN EN ) l/min at bar and 3 m geod. 5 l/min at bar and 1.5 m geod. Drive: Via joint shafts from the PTO of the vehicle Basic fittings: Dual stage centrifugal fire pump, clockwise or anticlockwise rotation, with 1 size A suction inlet, size B delivery outlets, 1 connection for rapid intervention line, 1 connection for tank fill line, 1 connection for tank suction line (lockable by means of a butterfly valve) 1 1 TROKOMAT PLUS, fully automatic Gauges and controls: Modular operation and control panel BKT, please see page Colour: Silver RAL 9 Dim. (LxWxH): x9x5 mm Weight: 115 kg 1 1 3 9 geod. = 7.5 m 1 15 geod. =. m geod. =.5 m geod. = 3. m geod. = 1.5 m 1 7 3 Additional fittings (options): more delivery outlets, connection for another rapid intervention line, monitor connection, fitting of a pump proportioner points of guarantee: geod. 3 m geod. 7,5 m (Test floor performance complying with DIN EN ) Additional systems (options): ANS, TOURMAT D, AWZ system, TROKOMAT shut-off, MAD 3, draining device Anticlockwise FPN - - HL... 199 Clockwise FPN - - HR... 197 Anticlockwise FPN - - HHL... 1559 Clockwise FPN - - HHR... 1555 FPN - - H and FPH - 5-3 All FPN can be retrofitted with a HP-pump. Please see page 3, HP-pump. 7

CENTRIFUGAL FIRE PUMP FPN - 3-1 H FPN - 3-1 H Approv. No. AZ 33 ZIEGLER fire pump (rear-mounted) for vehicle PTO of 1 kw (19 HP) onwards 1 1 1 1 geod. = 7.5 m geod. =. m 3 geod. =.5 m geod. = 3. m geod. = 1.5 m 1 1 3 3 Nominal pump output: 3 l/min at bar and 3 m geod. Max. pump output: (test floor performance complying with DIN EN ) 3 l/min at bar and 3 m geod. l/min at bar and 1.5 m geod. Drive: Via joint shafts from the PTO of the vehicle Basic fittings: Single stage centrifugal fire pump, clockwise or anticlockwise rotation, with 1 size DN 15 suction inlet, 3 size B delivery outlets, 1 connection for rapid intervention line, 1 connection for tank fill line, 1 connection for tank suction line (lockable by means of a butterfly valve) TROKOMAT PLUS, fully automatic Gauges and controls: Modular operation and control panel BKT, please see page Colour: Silver RAL 9 Dim. (LxWxH): x9x5 mm Weight: 9 kg points of guarantee: geod. 3 m geod. 7.5 m (Test floor performance complying with DIN EN ) Additional fittings (options): size A suction inlets, another delivery outlet, connection for another rapid intervention line, monitor connection, fitting of a pump proportioner FPN - 3-1 H and FPH - 5-3 All FPN can be retrofitted with a HP-pump. Please see page 3, HP-pump. Additional systems (options): ANS, TOURMAT D, AWZ system, TROKOMAT shut-off, MAD 3, draining device Anticlockwise FPN - 3-1 HL...197 Clockwise FPN - 3-1 HR...19 Anticlockwise FPN - 3-1 HHL...155 Clockwise FPN - 3-1 HHR...155

CENTRIFUGAL FIRE PUMP FPN - 3 - H FPN - 3 - H Approv. No. AZ 33 ZIEGLER fire pump (rear-mounted) for vehicle PTO of 5 kw (13 HP) onwards Nominal pump output: 3 l/min at bar and 3 m geod. Max. pump output: (test floor performance complying with DIN EN ) 35 l/min at bar and 3 m geod. 35 l/min at bar and 1.5 m geod. Drive: Via joint shafts from the PTO of the vehicle Basic fittings: Dual stage centrifugal fire pump, clockwise or anticlockwise rotation, with 1 size DN 15 suction inlet, 3 size B delivery outlets, 1 connection for rapid intervention line, 1 connection for tank fill line, 1 connection for tank suction line (lockable by means of a butterfly valve) TROKOMAT PLUS, fully automatic Gauges and controls: Modular operation and control panel BKT, please see page Colour: Silver RAL 9 Dim. (LxWxH): x9x5 mm Weight: 115 kg 1 1 1 1 geod. = 7.5 m 1 1 3 3 geod. =. m 3 geod. =.5 m geod. = 3. m = 1.5 m Additional fittings (options): size A suction inlets, another delivery outlet, connection for another rapid intervention line, monitor connection, fitting of a pump proportioner points of guarantee: geod. 3 m geod. 7.5 m (Test floor performance complying with DIN EN ) Additional systems (options): ANS, TOURMAT D, AWZ system, TROKOMAT shut-off, MAD 3, draining device Anticlockwise FPN - 3 - HL... 199 Clockwise FPN - 3 - HR... 197 Anticlockwise FPN - 3 - HHL... 1559 Clockwise FPN - 3 - HHR... 1555 FPN - 3 - H and FPH - 5-3 All FPN can be retrofitted with a HP-pump. Please see page 3, HP-pump. 9

CENTRIFUGAL FIRE PUMP FPN - - H FPN - - H Approv. No. AZ 3 ZIEGLER fire pump (rear-mounted) for vehicle PTO of 13 kw (1 HP) onwards 1 1 1 1 geod. = 7.5 m geod. =. m geod. =.5 m geod. = 3. m geod. = 1.5 m 5 15 5 3 35 5 5 55 points of guarantee: geod. 3 m geod. 7.5 m (Test floor performance complying with DIN EN ) Nominal pump output: l/min at bar and 3 m geod. Max. pump output: (test floor performance complying with DIN EN ) 7 l/min at bar and 3 m geod. 5 l/min at bar and 1.5 m geod. Drive: Via joint shafts from the PTO of the vehicle Basic fittings: Dual stage centrifugal fire pump, clockwise or anticlockwise rotation, with flange for suction inlet and flange for delivery outlet TROKOMAT PLUS, fully automatic Gauges and controls: Modular operation and control panel BKT, please see page Colour: Silver RAL 9 Dim. (LxWxH): 1x1x97 mm Weight: 97 kg (basic pump) Additional fittings (options): size Storz A suction inlets, alternatively 1 size Storz 15 suction inlet, tank suction connection size DN 15, up to size B delivery outlets, 1 monitor outlet, delivery outlets to rapid intervention units, 1 outlet for tank fill line, fitting of a pump proportioner FPN - - H and FPH - 5-3 All FPN can be retrofitted with a HP-pump. Please see page 3, HP-pump. Additional systems (options): ANS, TOURMAT D, draining device, TROKOMAT shut-off, MAD 5 Anticlockwise FPN - - HL...155 Clockwise FPN - - HR...1555 Anticlockwise FPN - - HHL...155 Clockwise FPN - - HHR...1557 3

CENTRIFUGAL FIRE PUMP FPN - - H FPN - - H Approv. No. AZ 3 ZIEGLER fire pump (rear-mounted) for vehicle PTO of kw (7 HP) onwards Nominal pump output: l/min at bar and 3 m geod. Max. pump output: (test floor performance complying with DIN EN ) 7 l/min at bar and 3 m geod. l/min at bar and 1.5 m geod. Drive: Via joint shafts from the PTO of the vehicle Basic fittings: Dual stage centrifugal fire pump, clockwise or anticlockwise rotation, with flange for suction inlet and flange for delivery outlet TROKOMAT PLUS, fully automatic Gauges and controls: Modular operation and control panel BKT, please see page Colour: Silver RAL 9 Dim. (LxWxH): 13xx75 mm Weight: 1 kg (basic pump) Additional fittings (options): size Storz 15 suction inlets, alternatively 1 size DN suction inlet, size DN 15 tank suction connections, up to size B delivery outlets or size A delivery outlets (lockable by means of an intermediate valve), monitor outlets, delivery outlets to rapid intervention units, 1 outlet for tank fill line, fitting of a pump proportioner Additional systems (options): ANS, TOURMAT D, draining device, TROKOMAT shut-off, EAD Anticlockwise FPN - - HL... 15 Clockwise FPN - - HR... 157 Anticlockwise FPN - - HHL... 15 Clockwise FPN - - HHR (rotation, please see page)... 159 1 1 1 1 geod. = 7.5 m 3 5 7 9 points of guarantee: geod. 3 m, geod. 7.5 m (Test floor performance complying with DIN EN ) geod. =. m geod. =.5 m geod. = 3. m geod. = 1.5 m FPN - - H and FPH - 5-3 All FPN can be retrofitted with a HP-pump. Please see page 3, HP-pump. 31

CENTRIFUGAL FIRE PUMPS FPN - - 1 H AND FPN - - 1 HH Picture with HP-pump FPN - - 1 H and FPN - - 1 HH ZIEGLER centrifugal fire pump (rear-mounted) for vehicle PTO or aggregate of 7 kw (H), 3 kw (HH) onwards Pump output in separate operation: Normal pressure pump (H): l/min at bar and 3 m geod. High pressure pump (HH): 5 l/min at bar Max. pump output:, l/min at bar and 1.5 m geod. Drive: Via joint shafts from the PTO of the vehicle or pump aggregate 1 1 Basic fittings: Single stage centrifugal fire pump with flange for suction inlet and flange for delivery outlet. The high pressure pump is attached, with a high pressure outlet to the rapid intervention unit. TROKOMAT PLUS, fully automatic 1 1 15 3 5 75 9 5 1 135 Additional systems (options): ANS, TOURMAT D, AWZ system, draining device, foam agent proportioning system Gauges and controls: Normal pressure pump: 1 manometer and 1 mano-vacuummeter, 1 running hour meter High pressure pump: 1 high pressure manometer, switch and control lamp Colour: Silver RAL 9 Dim. (LxWxH): FPN - - 1 H: 73x7x77 mm FPN - - 1 HH: 7x7x5 mm Weight: FPN - - 1 H: kg (basic pump) FPN - - 1 HH: 5 kg with HP-pump Anticlockwise FPN - - 1 HL...19913 Clockwise FPN - - 1 HR...1991 Anticlockwise FPN - - 1 HHL...19915 Clockwise FPN - - 1 HHR...1991 Additional fittings (options): 1 size DN 5 central suction inlet (to water tank) or 3 size F suction inlets DN 5, connected by means of a collecting head. Up to size B or size A delivery outlets (lockable by means of an intermediate valve). Up to delivery outlets to rapid intervention units. 1 outlet for tank fill line. Up to monitor outlets. Outlet for another high pressure rapid intervention line for the high pressure pump. 3

CENTRIFUGAL FIRE PUMP FPN 15 - - H FPN 15 - - H Approv. No. AZ 153 ZIEGLER fire pump (rear-mounted) for vehicle PTO of 75 kw ( HP) onwards Nominal pump output: l/min at bar and 3 m geod. Max. pump output: (test floor performance complying with DIN EN ) 19 l/min at bar and 3 m geod. l/min at bar and 1.5 m geod. Drive: Via joint shafts from the PTO of the vehicle Basic fittings: Dual stage centrifugal fire pump, clockwise or anticlockwise rotation, with 1 size A suction inlet, size B delivery outlets, 1 connection for rapid intervention line, 1 connection for tank fill line, 1 connection for tank suction line (lockable by means of a butterfly valve) TROKOMAT PLUS, fully automatic Gauges and controls: Modular operation and control panel BKT, please see page Colour: Silver RAL 9 Dim. (LxWxH): 75x75x mm Weight: 7 kg Additional fittings (options): more delivery outlets, connection for a second rapid intervention line, monitor connection, fitting of a pump proportioner Additional systems (options): ANS, TOURMAT D, AWZ system, TROKOMAT shut-off, draining device Anticlockwise FPN 15 - - HL... 1935 Clockwise FPN 15 - - HR... 195 Anticlockwise FPN 15 - - HHL... 155 Clockwise FPN 15 - - HHR... 155 1 1 15 1 1 geod. = 7.5 m 1 1 1 1 points of guarantee: geod. 3 m geod. 7.5 m (Test floor performance complying with DIN EN ) geod. =. m geod. =.5 m geod. = 3. m geod. = 1.5 m FPN 15 - - H and FPH - 5-3 All FPN can be retrofitted with a HP-pump. Please see page 3, HP-pump. 33

CENTRIFUGAL FIRE PUMP FPN 15 - - 1 H FPN 15 - - 1 H Approv. No. AZ 153 ZIEGLER fire pump (rear-mounted) for vehicle PTO of 15 kw (17 HP) onwards Nominal pump output: l/min at 15 bar and 3 m geod. Max. pump output: (test floor performance complying with DIN EN ) 5 l/min at bar and 3 m geod. l/min at bar and 1.5 m geod. Drive: Via joint shafts from the PTO of the vehicle 1 1 15 1 1 3 9 geod. = 7.5 m geod. =. m geod. =.5 m geod. = 3. m geod. = 1.5 m 1 15 1 7 3 points of guarantee: geod. 3 m geod. 7.5 m (Test floor performance complying with DIN EN ) Basic fittings: Single stage centrifugal fire pump, clockwise or anticlockwise rotation, with 1 size A suction inlet, size B delivery outlets, 1 connection for rapid intervention line, 1 connection for tank fill line, 1 connection for tank suction line (lockable by means of a butterfly valve) TROKOMAT PLUS, fully automatic Gauges and controls: Modular operation and control panel BKT, please see page Colour: Silver RAL 9 Dim. (LxWxH): x9x5 mm Weight: 9 kg Additional fittings (options): more delivery outlets, connection for a second rapid intervention line, connection for monitor, fitting of a pump proportioner FPN 15 - - 1 H and FPH - 5-3 All FPN can be retrofitted with HP-pump. Please see page 3, HP-pump. Additional systems (options): ANS, TOURMAT D, AWZ system, TROKOMAT shut-off, MAD 3, draining device Anticlockwise FPN 15 - - 1 HL...197 Clockwise FPN 15 - - 1 HR...19 Anticlockwise FPN 15 - - 1 HHL...155 Clockwise FPN 15 - - 1 HHR...155 3

CENTRIFUGAL FIRE PUMP FPN 15 - - H FPN 15 - - H Approv. No. AZ 153 ZIEGLER fire pump (rear-mounted) for vehicle PTO of kw (17 HP) onwards Nominal pump output: l/min at bar and 3 m geod. Max. pump output: (test floor performance complying with DIN EN ) 5 l/min at bar and 3 m geod. 9 l/min at bar and 1.5 m geod. Drive: Via joint shafts from the PTO of the vehicle Basic fittings: Dual stage centrifugal fire pump, clockwise or anticlockwise rotation, with 1 size A suction inlet, size B delivery outlets, 1 connection for rapid intervention line, 1 connection for tank fill line, 1 connection for tank suction line (lockable by means of a butterfly valve) TROKOMAT PLUS, fully automatic Gauges and controls: Modular operation and control panel BKT, please see page Colour: Silver RAL 9 Dim. (LxWxH): x9x5 mm Weight: 115 kg Additional fittings (options): more delivery outlets, connection for a second rapid intervention line, connection for monitor, fitting of a pump proportioner 1 1 15 1 1 3 geod. = 7.5 m 9 1 15 1 7 3 points of guarantee: geod. 3 m geod. 7.5 m geod. =. m (Test floor performance complying with DIN EN ) geod. =.5 m geod. = 3. m geod. = 1.5 m Additional systems (options): ANS, TOURMAT D, AWZ system, TROKOMAT shut-off, MAD 3, draining device Anticlockwise FPN 15 - - HL... 199 Clockwise FPN 15 - - HR... 197 Anticlockwise FPN 15 - - HHL... 1559 Clockwise FPN 15 - - HHR... 1555 FPN 15 - - H and FPH - 5-3 All FPN can be retrofitted with a HP-pump. Please see page 3, HP-pump. 35

CENTRIFUGAL FIRE PUMP FPN 15-3 - 1 H FPN 15-3 - 1 H Approv. No. AZ 1533 ZIEGLER fire pump (rear-mounted) for vehicle PTO of 15 kw (5 HP) onwards 1 1 15 1 1 FPN 15-3 - 1 H and FPH - 5-3 All FPN can be retrofitted with a HP-pump. Please see page 3, HP-pump. geod. = 7.5 m points of guarantee: geod. 3 m geod. 7.5 m geod. =. m 3 1 1 3 3 (Test floor performance complying with DIN EN ) geod. =.5 m geod. = 3. m geod. = 1.5 m Nominal pump output: 3 l/min at 15 bar and 3 m geod. Max. pump output: (test floor performance complying with DIN EN ) 37 l/min at bar and 3 m geod. l/min at bar and 1.5 m geod. Drive: Via joint shafts from the PTO of the vehicle Basic fittings: Single stage centrifugal fire pump, clockwise or anticlockwise rotation, with size DN 15 suction inlet, 3 size B delivery outlets, 1 connection for rapid intervention line, 1 connection for tank fill line, 1 connection for tank suction line (lockable by means of a butterfly valve) TROKOMAT PLUS, fully automatic Gauges and controls: Modular operation and control panel BKT, please see page Colour: Silver RAL 9 Dim. (LxWxH): x9x5 mm Weight: 9 kg Additional fittings (options): Another delivery outlet, connection for a second rapid intervention line, connection for monitor, fitting of a pump proportioner Additional systems (options): ANS, TOURMAT D, AWZ system, TROKOMAT shut-off, MAD 3, draining device Anticlockwise FPN 15-3 - 1 HL...197 Clockwise FPN 15-3 - 1 HR...19 Anticlockwise FPN 15-3 - 1 HHL...155 Clockwise FPN 15-3 - 1 HHR...155 3

CENTRIFUGAL FIRE PUMP FPN 15-3 - H FPN 15-3 - H Approv. No. AZ 1533 ZIEGLER fire pump (rear-mounted) for vehicle PTO of 17 kw (3 HP) onwards Nominal pump output: l/min at bar and 3 m geod. Max. pump output: (test floor performance complying with DIN EN ) l/min at bar and 3 m geod. 5 l/min at bar and 1.5 m geod. Drive: Via joint shafts from the PTO of the vehicle Basic fittings: Dual stage centrifugal fire pump, clockwise or anticlockwise rotation, with flange for suction inlet and flange for delivery outlet TROKOMAT PLUS, fully automatic Gauges and controls: Modular operation and control panel BKT, please see page Colour: Silver RAL 9 Dim. (LxWxH): 1x1x97 mm Weight: 97 kg (basic pump) Additional fittings (options): size Storz A suction inlets, alternatively 1 size Storz 15 suction inlet, tank suction connection DN 15, up to size B delivery outlets, 1 monitor outlet, outlets to rapid intervention units, 1 outlet for tank fill line, fitting of a pump proportioner Additional systems (options): ANS, TOURMAT D, draining device, TROKOMAT shut-off, MAD 5 Anticlockwise FPN 15-3 - HL... 155 Clockwise FPN 15-3 - HR... 1555 Anticlockwise FPN 15-3 - HHL... 155 Clockwise FPN 15-3 - HHR... 1557 1 1 15 1 1 geod. Saughöhe = 7.5 m 5 15 5 3 35 5 5 55 points of guarantee: geod. 3 m geod. 7.5 m (Test floor performance complying with DIN EN ) geod. Saughöhe =. m geod. Saughöhe =.5 m geod. Saughöhe = 3. m geod. Saughöhe = 1.5 m FPN 15-3 - H and FPH - 5-3 All FPN can be retrofitted with a HP-pump. Please see page 3, HP-pump. 37

Kap.-3 9.3.5 1:5 Uhr Seite 3 CENTRIFUGAL FIRE PUMP FPH - 5-3 FPH - 5-3 Approv. No. AZ 33 ZIEGLER fire pump Attachable pump for all normal pressure pumps Power required: 5-9 kw The required high pressure power must be added to the figures of the respective normal pressure pump! Nominal pump output: 5 l/min at bar Max. pump output: (test floor performance complying with DIN EN ) 59 l/min at bar Drive: The pump is put into circuit via gear drive and electromagnetic clutch. Basic fittings: 3-stage centrifugal fire pump, clockwise or anticlockwise rotation, with normal pressure inlets, left or right, with feed line. 1 high pressure outlet with distributor and 1 or hand-operated high pressure outlets, drain valve, thermal discharge line. 5 3 5 3 5 points of guarantee: 15 l/min bar 5 l/min 7 bar (Test floor performance complying with DIN EN ) Example: FPN - 75 - H and FPH - 5-3 All FPN can be retrofitted with a HP-pump. 3 Gauges and controls: High pressure indicator or possibly button high pressure ON/OFF on the modular operation and control panel BKT, please see page Colour: Silver RAL 9 Dim. (LxWxH): 3x3x mm Weight: 5 kg Additional fittings (options): Another high pressure outlet, all high pressure outlets remote controlled, electronic pressure limitation, audible overheating warning device, electronic overheating protection with automatic water exchange

PUMP UNIT FP 1/- A 1 1 1 point of guarantee: 1,5 m and 3 m geod. suction height 7,5 m geod. m geod. suction height 1 1 1 1 3 m geod. FP 1/- A ZIEGLER fire pump unit FP 1/- A on mounting frame Max. pump output: 1 l/min at bar and 3 m geod. Engine: VW industrial Diesel engine type H ADG, -cyl. in-line engine, water-cooled, 1 kw (55 HP); with electric starter, battery 1 V/ Ah, generator 1 V/5 A, fuel tank l Basic fittings: Pump Dual stage centrifugal fire pump FP 1/-, with 1 size A suction inlet, size B delivery outlets with selfclosing globe valves complying with DIN-standard, suction inlet and delivery outlets with blank caps TROKOMAT PLUS, fully automatic Pump gauges: 1 manometer and 1 mano-vacuummeter mounted on the pump Controls: All instruments and switches necessary for the operation of the engine are found in a control box at the front side of the unit. Illumination: 1 telescopic halogen spotlight, illuminated control panel Colour: Frame: black Cover and pump: red (RAL 3) Dim. (LxWxH): 13x7x99 mm Weight: 31 kg...13 39

PUMP UNIT FP /-1 A FP /-1 A ZIEGLER fire pump unit FP /-1 A on mounting frame or for mounting on a truck or on chassis trailer Pump output: l/min at bar and 3 m geod. Max. pump output: 3 l/min at bar and 1.5 m geod. Engine: Mercedes-Benz Diesel engine (EURO ) type OM 9 LA, -cyl. in-line engine, turbocharger and boost intercooling, water-cooled, kw (13 HP), with electric starter. Power transmission to the pump by means of electromagnetic clutch and joint shaft, batteries 1 V/ Ah, fuel tank l. Basic fittings: Pump Single stage centrifugal fire pump FP /-1, with 1 size A suction inlet, size B delivery outlets with selfclosing globe valves complying with DIN-standard, suction inlet and delivery outlets with blank caps 1 1 1 TROKOMAT PLUS fully automatic Gauges: 1 manometer and 1 mano-vacuummeter installed together with the engine controls on the control panel Colour: Basic framerame: black Cover: red (RAL 3) Pump: silver (RAL 9) Dim. (LxWxH): x9x175 mm Weight: 5 kg 7,5 m geod. point of guarantee: Additional fittings (options): additional delivery outlets, fitting of a pump proportioner, spotlight...195 3 m geod. 1 1 3 3 3 m geod. 1,5 m geod. Single axle platform trailer for FP /-1 A and fire fighting accessories. With rubber-cushioned axle, overrunning brake, towbar adjustable in height and supporting wheel, with positioning supports, illumination complying with StVZO (German road regulations). Colour: Frame, wheels and towbar: black Mudguards: white Dim. (LxWxH): x1955x1 mm Weight: kg G.V.W.: 1 kg...17

PUMP UNIT FP /- A 1 1 1 1 FP /- A 1 1 3 3 5 point of guarantee: 7,5 m geod. 3 m geod. ZIEGLER fire pump unit FP /- A on mounting frame or for mounting on a track or on chassis trailer Pump output: l/min at bar and 3 m geod. Engine: Mercedes-Benz Diesel engine (EURO ) type OM 9 LA, -cyl. in-line engine, turbo-charger and boost intercooling, water-cooled, 15 kw (17 HP), with electric starter. Power transmission to the pump by means of electromagnetic clutch and joint shaft, fuel tank 5 l. 3 m geod. 1,5 m geod. Basic fittings: Pump Dual stage centrifugal fire pump FP /-, with size A suction inlets, size B delivery outlets with selfclosing globe valves complying with DIN-standard, suction inlets and delivery outlets with blank caps TROKOMAT PLUS, fully automatic Gauges: 1 manometer and 1 mano-vacuummeter installed together with the engine controls on the control panel Colour: Basic frame: black Cover: red (RAL 3) Pump: silver (RAL 9) Dim. (LxWxH): xx15 mm Weight: 11 kg Additional fittings (options): Fitting of a pump proportioner, spotlight...199 Single axle platform trailer for FP /- A and fire fighting accessories. With rubber-cushioned axle, overrunning brake, towbar adjustable in height and supporting wheel, with positioning supports, illumination complying with StVZO (German road regulations). Colour: Frame, wheels and towbar: black Mudguards: white Dim. (LxWxH): 5xx1 mm Weight: 5 kg G.V.W.: 5 kg...179 1

PUMP UNIT FP /- A 1 1 1 1 7,5 m geod. 3 m geod. 1,5 m geod. 3 5 7 9 point of guarantee: 3 m geod. FP /- A ZIEGLER fire pump unit FP /- A on mounting frame or for mounting on a truck or on chassis trailer Pump output: l/min at bar and 3 m geod. Engine: Mercedes-Benz Diesel engine (EURO ) type OM 9 LA, -cyl. in-line engine, turbo-charger and boost intercooling, water-cooled, 5 kw (7 HP), with electric starter. Power transmission to the pump by means of electromagnetic clutch and joint shaft, fuel tank 1 l. Basic fittings: Pump Dual stage centrifugal fire pump FP /-, with size Storz 15 suction inlets, size B delivery outlets with self-closing globe valves complying with DIN-standard. Alternatively size A delivery outlets with shut-off valve and size B delivery outlets. Suction inlets and delivery outlets with blank caps. TROKOMAT PLUS, fully automatic Gauges: 1 manometer and 1 mano-vacuummeter installed together with the engine controls on the control panel Colour: Basic frame: black Cover: red (RAL 3) Pump: silver (RAL 9) Dim. (LxWxH): 3x1x1 mm Weight: 195 kg Additional fittings (options): Fitting of a pump proportioner, spotlight...1951 Single axle platform trailer for FP /- A and fire fighting accessories. With rubber-cushioned axle, overrunning brake, towbar adjustable in height and supporting wheel, with positioning supports, illumination complying with StVZO (German road regulations). Colour: Frame, wheels and towbar: black Mudguards: white Dim. (LxWxH): xx1 mm Weight: kg G.V.W.: 35 kg...395

PORTABLE PUMP TS / ULTRA-POWER 1 1 1 7,5 m geod. 1 point of guarantee: 3 m geod. 7,5 m geod. TS / Ultra-Power PVR 3//97 The TS portable pump complying with DIN-standard with the highest output»the environment-friendly one«high performance: 1 l/min at bar and 3 m geod. Reliable VW Polo -stroke aluminium engine (worldwide VW service facilities) Low pollution, low vibration and low noise Performance as draining pump l/min at 3 m geod. suction height Nominal output: l/min at bar and 3 m geod. Pump output (approx.): at 3 m geod. : 195 l/min at bar 1 l/min at bar 15 l/min at bar at 1.5 m geod. : 15 l/min at bar at 7.5 m geod. : 5 l/min at bar Pump: Single stage centrifugal fire pump, high efficiency - approx. 7%. Watercarrying parts made of sea-water resistant light metal alloy or stainless steel. Sealing of pump shaft by means of radial seals. With size A suction inlet and size B delivery outlets with selfclosing globe valves, all with couplings and blank caps. Power transmission from engine via single-plate dry clutch. 3 m geod. 1 1,5 m geod. TROKOMAT PLUS, fully automatic Engine: VW Polo -cyl. -stroke aluminium engine with electronic fuel injection and lambda control, type ATE. Power: 37 kw (5 HP) at 5 rpm, 999 cc. Cooling through closed cooling water circuit with heat exchanger and additional cooling system (patented). Electronic -stage rpm-limiter for suction and max. rpm acting on the injection unit. Contactless battery ignition, maintenance-free hydraulic valve lift system. Starter: Electric starter. Emergency start by means of pull starter. Engine cowling of plastic. Fuel tank: 1 l for unleaded premium petrol (RON 95) sufficient for hours at nominal performance. Gauges and controls: Functional and clear arrangement of all gauges and controls on the pump. Manometer, mano-vacuummeter, running hour meter as well as all engine controls: Ignition switch, rotary knob for throttle (easy operation without choke), control lamps for oil pressure, water temperature, battery charge and suction rpmlimitation. Clutch lever between pump and engine cowling. Lighting system: 1 halogen spotlight, extensible Carrying frame: High-strength light metal frame with foldable handles adjustable to 9º with cold-protective covering of rubber Dim. (LxWxH): 5x7x3 mm Weight: 19 kg (ready for use) ZIEGLER portable pump TS / single stage, with automatic priming system TROKOMAT PLUS...9 ZIEGLER portable pump TS / single stage, with automatic priming system TROKOMAT PLUS and automatic pressure governor Tourmat D...1 Tourmat D The automatic pressure governor Tourmat D takes some of the load off the operator during action. In case of change in water delivery, e.g. when nozzles are opened and closed, the pressure is adjusted within fractions of a second and is kept constant. This is particularly advantageous if several pumps are connected in series. 3

PORTABLE PUMP TS / ULTRA-LIGHT 1 1 TS / Ultra-Light PVR 357/7/9 The TS portable pump complying with DIN-standard with the lowest weight The pump that sets standards Low weight: 1 kg High performance: 1 l/min at bar and 3 m geod. Easy-to-start ZIEGLER/Hirth -cyl. engine, 3 kw (9 HP), aircooled, with auto-lube system Performance as draining pump: l/min at 3 m geod. suction height Nominal output: l/min at bar and 3 m geod. Pump output (approx.): at 3 m geod. : 19 l/min at bar 1 l/min at bar 13 l/min at bar at 1.5 m geod. : 15 l/min at bar at 7.5 m geod. : 95 l/min at bar 1 Pump: Single stage centrifugal fire pump, high efficiency - approx. 7%. Watercarrying parts made of sea-water resistant light metal alloy or stainless steel. Sealing of pump shaft by means of radial seals. With size A suction inlet and size B delivery outlets with self-closing globe valves, all with couplings and blank caps. Power transmission from engine via single-plate dry clutch. TROKOMAT PLUS, fully automatic Engine: ZIEGLER/Hirth -cyl. engine, aircooled, diaphragm controlled, with auto-lube system, 5 cc, power 3 kw (9 HP) at 9 rpm. Noise suppressing design of engine cowling. With l fuel tank for unleaded/leaded premium petrol, lubricant tank and pull starter. Rpm/load controlled auto-lube with low level oil warning lamp and automatic shut-off when no oil is left. Option: Electric starter and 1 V battery with charging socket. Engine cowling of plastic. 7,5 m geod. 3 m geod. suction height 1,5 m geod. suction height 1 1 1 1 point of guarantee: 3 m geod. 7,5 m geod. Gauges and controls: Modern operating panel with 1 manometer and 1 mano-vacuummeter, running hour meter, rotary knobs for throttle and air, control lamps oil and cooling and shut-off. Start button for version with electric starter. Clutch lever between pump and engine cowling. Lighting system: 1 halogen spotlight, extensible, illuminated operating panel Carrying frame: High-strength light metal frame with foldable handles adjustable to 9º with cold-protective covering Dim. (LxWxH): 5x75x5 mm Weights (ready for use): 1 kg (without electric starter) 15 kg (with electric starter) ZIEGLER portable pump TS / single stage, with automatic priming system TROKOMAT PLUS...1193 ZIEGLER portable pump TS / single stage, with automatic priming system TROKOMAT PLUS, with additional electric starter and battery...1193

PORTABLE PUMP TS / ULTRA-COMPACT 9 7 5 3 1 7,5 m geod. suction height 3 m geod. suction height 3 5 7 9 1 point of guarantee: 3 m geod. TS / Ultra-Compact The compact one of the ZIEGLER ULTRA -line models»the small strong one«dual stage ZIEGLER centrifugal fire pump with time-tried components Reliable, low noise Briggs & Stratton -stroke engine (worldwide service facilities) Standard automatic priming system Storage space identical with 5 kva generator, DIN 15 Nominal output: l/min at bar and 3 m geod. Pump output (approx.): at 3 m geod. : l/min at bar 5 l/min at bar l/min at bar at 1.5 m geod. : 9 l/min at bar at 7.5 m geod. : 3 l/min at bar 1,5 m geod. suction height Pump: Dual stage centrifugal fire pump. Water-carrying parts made of seawater resistant light metal alloy or stainless steel. Impellers with stainless steel split water rings. Sealing of pump shaft by means of radial seals. With size B suction inlet with blank cap and 1 size B delivery outlet with selfclosing globe valve. Power transmission from engine via automatic centrifugal clutch. TROKOMAT PLUS, fully automatic Engine: Briggs & Stratton -cyl., -stroke V-engine, 57 cc, power 13 kw (1 HP) at 3 rpm, with.5 l fuel tank for unleaded or leaded petrol (not below 5 RON), air-cooled by means of blower. Maintenance-free, electronic, contactless magneto ignition. Starting system with recoil starter and with electric starter and battery. Gauges and controls: 1 manometer and 1 mano-vacuummeter on the pump. Modern operating panel with rotary knob for throttle, shut-off button, ignition switch, running hour meter, oil pressure warning lamp and halogen spotlight. Carrying frame: High-strength light metal frame with foldable handles with cold-protective covering Dim. (LxWxH): 75xx59 mm Weight (ready for use): 9 kg ZIEGLER portable pump TS / dual stage, with automatic priming system TROKOMAT PLUS, with electric starter and battery...19 5

PORTABLE PUMP TS /5 ULTRA-PICCO 7 5 3 1 5 point of guarantee: 15 m geod. suction height 5 3 3 m geod. 3 m geod. suction height 35 5 1,5 m geod. suction height 5 55 TS /5 Ultra-Picco The smallest one of the ZIEGLER ULTRA -line models Nominal pump output: l/min at 5 bar and 3 m geod. Max. pump output: l/min at bar and 1.5 m geod. Pump: Single stage centrifugal fire pump with impeller open on one side, designed for dirty water. Water-carrying parts made of sea-water resistant light metal alloy. Shaft made of stainless steel. Pump shaft sealing by means of radial seals. With 1 size C5 suction inlet, 1 size C5 delivery outlet with selfclosing globe valve, both with coupling and blank cap. Direct power transmission engine-pump. Engine: Göbler-Hirth 1-cyl., -stroke engine type H15, air-cooled, 1 cc, power. kw (.3 HP) at 5 rpm. With recoil-starter and 3. l tank for mixture 1:5. Piston pump, manual Gauges and controls: 1 mano-vacuummeter with protective cap on the pump housing, throttle Carrying frame: Of steel pipe Dim. (LxWxH): 55xx mm Weight (ready for use): 3.5 kg ZIEGLER portable pump TS /5 H15 single stage, with piston pump priming system...13 Protective hood of lattice plastic *...53

PORTABLE PUMPS WITH DIESEL ENGINE TS /- AND TS D TS /- 1 1 1 1.5 m geod. 7.5 m geod. 3 m geod. 3 5 7 9 points of guarantee: geod. 3 m geod. 7.5 m TS /- with Diesel engine TS D TS D with Diesel engine Pump output: l/min at bar and 3 m geod. l/min at bar and 3 m geod. Max. pump output: 95 l/min at bar and 1.5 m geod. Pump: Dual stage ZIEGLER centrifugal fire pump, water-carrying parts made of sea-water resistant light metal alloy, shaft made of stainless steel. Sealing of the pump shaft by means of radial seals. With size B suction inlet and size B delivery outlet with self-closing globe valve, size B couplings. Engine: Ruggerini -cyl., -stroke Diesel engine, type MD 191, direct injection, air-cooled, power 1 kw (1.3 HP) at 3 rpm, 51 cc. With electric starter as well as emergency roller starter. l fuel tank. TROKOMAT PLUS, fully automatic Gauges and controls: 1 manometer and 1 mano-vacuummeter, operating panel with throttle and ON/OFF button Carrying frame: Carrying/protective frame of steel pipe with foldable handles. Dim. (LxWxH): 5x5x53 mm Weight: 11 kg (ready for use) 1 1 1 7,5 m geod. suction 3 m geod. suction 1,5 m geod. suction height height height 1 1 1 1 Pump output: l/min at bar and 3 m geod. 1 l/min at bar and 3 m geod. Pump: Dual stage ZIEGLER centrifugal fire pump, water-carrying parts made of sea-water resistant light metal alloy, shaft of stainless steel. Sealing of the pump shaft by means of radial seals. With size A suction inlet and size B delivery outlets with self-closing globe valves. Size B couplings and blank caps. Power transmission from engine by means of centrifugal clutch. Engine: Ruggerini -cyl., -stroke Diesel engine, type RD 7, direct injection, air-cooled, continuous power kw (7 HP) at 3 rpm, 1 cc. With electric starter and l fuel tank. TROKOMAT PLUS, fully automatic Gauges and controls: 1 manometer and 1 mano-vacuummeter on the pump. Operating panel with throttle and ON/OFF button. Carrying frame: Carrying/protective frame of steel pipe with foldable handles Dim. (LxWxH): 95x5x3 mm Weight: 17 kg (ready for use but without battery) ZIEGLER portable pump TS / dual stage, with automatic priming system TROKOMAT PLUS...331 ZIEGLER portable pump TS D dual stage, with automatic priming system TROKOMAT PLUS...11 7

ZIEGLER portable pumps with the automatic priming system TROKOMAT PLUS - high performance, reliable, well-proven for decades in tough actions. ZIEGLER builds portable pumps with various performances: from up to l/min, e.g. from the small light-weight TS /5 Ultra- Picco up to the high-performance TS / Ultra-Power. With powerful -stroke or -stroke engines or as a Diesel aggregate. One thing they all have in common: The time-tried construction with extremely efficient priming systems and rugged, reliable engines make our portable pumps sought-after and reliable partners to the fire brigades in many countries of the world. More than 7, ZIEGLER portable pumps are in use worldwide. Albert Ziegler GmbH & Co. KG Manufacturers of fire service vehicles, pumps and hoses Memminger Str. 9537 Giengen Germany Phone +9 73 951- Fax +9 73 951- WWW: http://www.ziegler.de E-Mail: export@ziegler.de Version: 5/5