SINGLE PACKAGE VERTICAL AIR CONDITIONERS



Similar documents
Single Package Vertical Air Conditioners. Vert-I-Pak

PACKAGED TERMINAL AIR CONDITIONERS

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

Thru-the-wall AIR CONDITIONERS COOL ONLY HEAT PUMPS ELECTRIC HEAT

catalog Single Package Vertical Air Conditioners and Heat Pumps

Catalog McQuay Type EA Incremental Air Conditioner and Heat Pump

INSTALLATION & OPERATION GUIDE

INSTALLATION & OPERATION GUIDE

Energy Efficiency. Energy Efficient Home Cooling:

FTQ. Daikin Inverter Ducted Heat Pump

SPACE COOLERS. P.O. Box 956 Paoli, PA (800) FAX (610) The leader in packaged Space Cooling.

Glossary of Heating, Ventilation and Air Conditioning Terms

ARMSTRONG AIR HEAT PUMPS

BVCAA inc HVAC Service Bid Sheet Item Description. Materials Labor Total 3/24/2015

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03

WINDOW ROOM AIR CONDITIONER

Ductless Heat Pumps. Gary Nordeen January

SECTION HEAT PUMPS

PRODUCT CATALOG. Indoor Units

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

ECO-AIR AIR CONDITIONING

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

york air-conditioning products Residential & VRF News 2015

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

PTAC Preventive Maintenance Guide. Step-by-step instructions and information to keep your units operating in peak condition

SECTION AIR CONDITIONING UNIT

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

HVAC Systems: Overview

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

EFFECTIVE OCTOBER Atwood Furnaces. and Digital Thermostats

RHF High Efficiency Remote Heat Pumps and Matching Blower Coils

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Packaged Terminal Air Conditioner Wall Sleeve Installation

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS

Room Air Conditioners

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

Chilled Water Fan Coil Unit. Model:HFCA Size 03~14

SECTION MORTUARY REFRIGERATORS

FTXS. Wall Mount Heat Pump or Cooling Only

Bard Manufacturing. Classroom Preferred School HVAC Solutions.

innovative comfort solutions

Split System Heat Pump Product Data

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes

LG AIR CONDITIONING SYSTEMS

MAC-120HE-01 Air-Cooled Chiller

Installation Instructions

ROOM AIR CONDITIONERS

I N T R O D U C I N G. COMMERCIAL GRADE DURABILITY with BUILT-IN, 7 DAY PROGRAMMABLE THERMOSTAT

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler

Product Data. Split System Cooling F-EN. March 2015

SPECIFICATIONS. Cooling Capacity BTUH 5,200. Approx. Sq. Ft. Cooling EER 9.7 Heating Capacity BTUH N/A (electric)

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Service & Parts Manual

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Split System Cooling Product Data

CE6500 Energy Recovery Ventilator

AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY

FOXAIR 60/50 ALL MODELS

QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

forair optimal air environments ResidentialPresentation

THREE. Heating and Cooling

HVAC Checklist - Long Form

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

heating 3 & cooling heating and cooling 2010 PulteGroup, Inc. All Rights Reserved.

LIFTAIRE I ELEVATOR AIR CONDITIONER

PACKAGED TERMINAL AIR CONDITIONER (PTAC) / PACKAGED TERMINAL HEAT PUMP (PTHP) AND ACCESSORY INSTALLATION INSTRUCTIONS

SMALL DUCT HIGH VELOCITY COMFORT SYSTEM

Evaluate, Clean, and Tune Guidance

Cooling Capacity CFM in. w.c. (125 Pa)

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Split System Cooling Product Data

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

FHQ. Ceiling Suspended Heat Pump or Cooling Only

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Cased/Uncased Coils For Gas And Oil Furnaces

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO

Commercial Gas Furnace Upflow

HSX19 Air Conditioner Up to SEER. Home Comfort Systems HSX19. The most quiet and efficient central air conditioner you can buy.

CEILING CASSETTE FAN COIL UNIT

CAB LCAB HACAB RMP/AMP CC CY/YY RVP CUSTOM CU

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

TEST REPORT #44. System Drop-in Tests of Refrigerant R-32 in Single Packaged Vertical Heat Pump (SPVH)

FREQUENTLY ASKED QUESTIONS about HERS and CHEERS Provided by the California Energy Commission Consumer Energy Center

FCQ. Roundflow Cassette Heat Pump or Cooling Only

Transcription:

SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com

VERT-I-PAK ideal for extended stay properties, suites, assisted living, student housing, and commercial spaces. Engineered for quieter performance with the aesthetics of a central air system and the simplicity of a PTAC. QUIETER BY DESIGN Friedrich s unique Free Floating chassis design The chassis slides into the wall plenum and a gasket firmly seals the chassis to the plenum. This eliminates vibration noises that are transmitted into the room in competitor s metalon-metal fixed installations. Available in capacities from 9200 to 23000 Btu, Vert-I-Pak can easily cool larger suites and common areas SIMPLE TO INSTALL CONCEALED INSTALLATION 9200, 11500 and 18000 Btu models 23000 Btu model What you ll find on Friedrich Vert-I-Pak Chassis installs into a wall plenum and is held firmly in place by a sealing gasket, reducing noise from vibration transfer. ½ inch foil-backed insulation added on the inside of the chassis to reduce sound transmission into the guest room. Extra thick, vibration-absorbing rubber grommets mounted on durable base that is engineered for structural and acoustic integrity. What you'll find on competitor's products Chassis is screwed into the wall plenum. Metal-on-metal contact transfers vibration, increasing operating noise under typical conditions. Noise is transferred through the walls and into the room. No insulation on the unit to reduce noise transmission into the guest room. Hard plastic feet on the unit base which are less durable and transfer harsh vibration noise. Dynamically balanced blower with large, vibration-absorbing motor mounts for smooth and quiet operation.

Totally concealed installation provides a more homelike appearance and quieter operation. QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION Easy installation Can be installed from any interior side (front, right or left) Compact and lightweight, weighs as little as 125 lbs. Easy installation; does not require an HVAC technician Ductable to multiple rooms All units are ready to install with only electrical hook up needed to be up and running. 24-volt remote thermostat ready 10 crimped and beaded duct-collar ready to attach flex duct Pre-wired, charged and piped Telescoping wall plenums adjust to fit varying exterior wall thicknesses Easy-to-connect, right or left drain connection All units are shipped (on pallet) with return air filter Rear or side wall sleeves Reliable and durable PSC permanently lubricated motor for low maintenance and maximum efficiency Engineered drain pan won t rust, eliminating the risk of unsightly rust stains from condensation on the building exterior Standard safety power disconnect Electronic control panel on unit for easy diagnostics and servicing 100% run tested prior to shipment- Every unit is tested in every operating mode before it ships for optimal performance and reliability Diamonblue advanced corrosion protection protects the outdoor coil against deterioration and extends the life of the unit especially in harsh coastal environments.

VERT-I-PAK better aesthetics outdoors Eliminates the clutter of outdoor condensing units and the need for vandalism barriers. OPTIONAL ACCESSORIES ARCHITECTURAL LOUVER VPAL2 and VPSC2 Extruded aluminum grille that attaches to the outdoor section of the wall plenum. Takes in fresh air and returns condensed air. VPSC2 can be ordered in custom colors. Dimensions: 25 9/16" W x 31 1/16" H WALL PLENUM VPAWP1-8, VPAWP1-14 Two-part sleeve that telescopes in and out. Sits inside the exterior wall penetration. VPAWP1-8 telescopes from 5 1/2 8 VPAWP1-14 telescopes from 8 14 Dimensions: 24 1/8 W x 30 3/8 H Cutout dimensions: 24 5/8 W x 30 7/8 H RETURN AIR GRILLE/ ACCESS PANEL VPRG4 Hinged panel allows access to unit and return air filter. A field-supplied filter (25" x 20") should be mounted on the inside the grille. Panel can be mounted with return air openings high or low on the door for optimum sound attenuation. Dimensions: 29" W x 58" H Cutout dimensions: 27" W x 55 3/4" H SINGLE STAGE THERMOSTAT RT6 Single stage, wall-mounted digital thermostat with two fan speeds and backlight for control of Friedrich VERT-I-PAK. DRAIN PAN VPDP1 For VEA/VHA24 models. May be installed prior to chassis for easy installation/removal.

6 VERT-I-PAK A better option inside and out Eliminates the clutter of outdoor condensing units and the need for vandalism barriers. Completely self-contained No refrigerant lines running from floor to floor Fast, easy replacement keeps spaces livable Improved guest comfort Individually controlled Heat and cool Duct air specifically where it s needed, not just on the outside wall 2-speed fan with constant fan option A better choice than whole building solutions Advantages Include: Lower installed cost Independent metering (no need to prorate for multitenant applications) Individual temperature set point (one unit can heat and others can cool) Less risk, with a whole building system spaces may become uninhabitable until the system is repaired or replaced Vert-I-Paks can be easily accessed for maintenance or replacement DIAMONBLUE Advanced Corrosion Protection protects the outdoor coil against deterioration and extends the life of the unit especially in harsh coastal environments. Typical Vert-I-Pak installation Field-supplied Filter (25" x 20") Rigid Ductwork 58" Exterior Wall Flexible Ductwork 29" Power Disconnect VPAWP1-8/1-14 Wall Plenum Plenum Divider VPRG4 Access Panel & Return Air Filter Grille Optional field installed drain pan (refer to local codes) Optional Platform 3" Clearance on all three sides minimum for service and installation Chassis is shipped with vibration isolators installed ACCESS DOOR OR PANEL TO CLOSET CAN BE INSTALLED FROM 3 SIDES VPDP1 drain pan beneath unit is required on all VEA/VHA24 units. Drain pan must be installed prior to chassis installation

SPECIFICATIONS Model VEA09K VEA12K VEA18K VEA24K VHA09K VHA12K VHA18K VHA24K COOLING DATA COOLING Btu 9400/9000 11500/11200 17000/16500 23000/22700 9200/8900 11500/11200 17000/16800 23000/22800 POWER (W) 959/918 1162/1140 1882/1860 2421/2389 939/908 1186/1155 1882/1860 2527/2505 EER 9.8/9.8 9.8/9.8 9.0/9.0 9.5/9.5 9.8/9.8 9.7/9.7 9.1/9.1 9.1/9.1 SENSIBLE HEAT RATIO 0.74 0.72 0.70 0.70 0.74 0.72 0.70 0.70 HEATER SIZE 2.5/3.4/5.0 2.5/3.4/5.0 2.5/3.4/5.0 2.5/3.4/5.0/7.5/10.0 2.5/3.4/5.0 2.5/3.4/5.0 2.5/3.4/5.0 2.5/3.4/5.0/7.5/10.0 HEAT PUMP DATA HEATING Btu 8500/8000 10800/10600 16000/15000 20000/20000 COP @ 47F 3.0/3.0 3.0/3.0 3.0/3.0 3.0/3.0 HEATING POWER (W) 830/811 1055/1035 1560/1540 1953/1953 HEATING CURRENT (A) 3.6/3.9 4.6/4.9 7.5/8.2 8.5/9.4 ELECTRICAL DATA VOLTAGE (1 PHASE, 60 Hz) 230/208 230/208 230/208 230/208 230/208 230/208 230/208 230/208 VOLT RANGE 253-198 253-198 253-198 253-198 253-198 253-198 253-198 253-198 COOLING CURRENT (A) 4.2/4.4 5.2/5.4 8.1/8.6 10.0/10.4 4.1/4.3 5.3/5.5 8.2/8.6 10.6/10.9 AMPS L.R. 22 30 42 34.8 18.5 26 42 34.8 AMPS F.L. 3.7 4.5 7.8 9.5 3.6 5 7.8 9.5 INDOOR MOTOR (HP) 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 INDOOR MOTOR (A) 1.2 1.2 1.2 1.94 1.2 1.2 1.2 1.94 OUTDOOR MOTOR (HP) 1/4 1/4 OUTDOOR MOTOR (A) 0.85 0.85 AIRFLOW DATA INDOOR CFM* 375 350 450 610 375 375 450 610 VENT CFM 60 60 60 60 60 60 60 60 MAX. ESP.3.3.3.4.3.3.3.4 PHYSICAL DIMENSIONS (W x D x H) 23"x23 x32 23 x23 x32 23 x23 x32 23"x23"x47" 23 x23 x32 23 x23 x32 23 x23 x32 23 x23 x47 NET WEIGHT (LBS) 114 124 144 167 114 125 144 167 SHIPPING WEIGHT (LBS) 125 135 155 220 125 135 155 220 TEST SETTING Low Low High Low Low High High Low R410A CHARGE (oz) 33.5 32 48.1 65 38.9 44 48 65 NOTES: Cooling Standards: 95 F DB/75 F WB outdoor, 80 F DB/67 F WB indoor Heating Standards: 47 F DB/43 F WB outdoor, 70 F DB/60 F WB indoor *Normal Value Wet Coil @.1" ESP. Friedrich Air Conditioning Co. l 10001 Reunion Place, Suite 500 l San Antonio, TX 78216 l 877.599.5665 l www.friedrich.com Commercial_VERT-I-PAK_Brochure_2012 (8-13) Printed in USA 0 C e r t - n o. X X X X X